×
Search
Quick links
Top documents
Trending documents
Help
Sitemap
We are hiring
Mobile developers: IOS & Android.
Apply now
en
English
English
Quick navigation
Login
Register
Upload
Search
Home
Categories
Top categories
View all
computers & electronics
Computers & electronics
home
industrial & lab equipment
Home
domestic appliances
audio & home theatre
TVs & monitors
software
networking
Industrial & lab equipment
vehicles & accessories
Domestic appliances
measuring, testing & control
electrical equipment & supplies
home security & automation
Do-It-Yourself tools
Networking
Audio & home theatre
Print & Scan
entertainment & hobby
Software
Home security & automation
computer components
Login
Upload
Home
Computers & electronics
Audio & home theatre
TV signal amplifiers
Akt18121 - Teledyne Cougar
Preview only show first 10 pages with watermark. For full document please download
Akt18121 - Teledyne Cougar
DOWNLOAD
EMBED
Rating
Date
November 2018
Size
101.2KB
Views
8,059
Categories
Computers & electronics
Audio & home theatre
TV signal amplifiers
Share
Transcript
Rev. 5/10 12.0 TO 18.0 GHz HIGH POWER SMA AMPLIFIER AKT18121 AKT18121 Typical Values High Output Power at 1 dB Compressed Point . . . . . . . High Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High Reverse Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . +30 dBm 35.0 dB 60 dB AKT18121 AKT-18121 SMA Amplifier Package SPECIFICATIONS* Parameter Typical Frequency (Min.) 12.0 - 18.0 GHz Guaranteed 0 to 50 °C -55 to +85 °C 12.0 - 18.0 GHz 12.0 - 18.0 GHz Small Signal Gain (Min.) 35.0 dB 31.0 dB 28.0 dB Gain Flatness (Max.) ±2.2 dB ±3.5 dB ±3.5 dB Noise Figure (Max.) 4.0 dB 6.5 dB 7.0 dB 1.8:1 2.5:1 2.5:1 +30.0 dBm +28.0 dBm +27.0 dBm SWR (Max.) Input/Output: Power Output (Min.) @ 1dB comp. Reverse Isolation 60.0 dB 50 dB 50 dB DC Current (Max.) 1856 mA 2100 mA 2100 mA Teledyne Cougar • 408-522-3838 • 408-522-3839 fax www.teledyne-cougar.com •
[email protected]
* Measured in a 50-ohm system at +12 Vdc unless otherwise specified. INTERMODULATION PERFORMANCE Typical @ 25 °C; 12000 MHz – 18000 MHz AKT18121 Second Order Harmonic Intercept Point. . . . . . . . . . . . . . . Second Order Two Tone Intercept Point . . . . . . . . . . . . . . . Third Order Two Tone Intercept Point . . . . . . . . . . . . . . . . . +69 dBm +63 dBm +37 dBm ABSOLUTE MAXIMUM RATINGS Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55° to +100 °C Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . . +85 °C Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +14.0 Volts Maximum Continuous RF Input Power . . . . . . . . . . . . . . . . +20 dBm Maximum Short Term Input Power (1µs) . . . . . . . . . . . . . . . +23 dBm Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +85 °C DIMENSIONS ARE IN INCHES [MILLIMETERS] 408-522-3838 • Fax: 408-522-3839 • Check for updates: www.teledyne-cougar.com AKT18121 TYPICAL PERFORMANCE 48.0 Gain vs Temperature Vcc = 12 TYPICAL AUTOMATIC TEST DATA KEY: +25°C +50°C +85°C 0°C -55°C GAIN - dB 44.0 40.0 36.0 32.0 28.0 11.5 12.0 13.0 14.0 15.0 FREQUENCY - GHz 16.0 17.0 18.0 18.5 14.0 15.0 FREQUENCY - GHz 16.0 17.0 Model: AKT18121 FREQ SWR GHz IN 11.5 1.71 12.0 1.79 12.5 1.59 13.0 1.31 13.5 1.26 14.0 1.39 14.5 1.55 15.0 1.47 15.5 1.27 16.0 1.15 16.5 1.32 17.0 1.44 17.5 1.44 18.0 1.30 18.5 1.24 SWR OUT 1.33 1.37 1.28 1.08 1.28 1.45 1.41 1.21 1.04 1.12 1.05 1.08 1.20 1.25 1.47 Vcc=+12V GAIN dB 36.52 36.95 35.93 35.76 37.47 39.16 39.46 39.25 38.83 38.72 38.29 37.67 36.68 35.49 33.16 PHASE DEG 89.31 -80.83 109.06 -46.82 151.14 -25.73 152.70 -28.63 152.56 -28.41 144.95 -42.92 121.58 -82.40 65.45 DELAY NSEC 00.93 00.94 00.91 00.85 00.87 00.97 01.01 01.02 01.00 01.02 01.06 01.06 01.09 01.18 01.21 Noise Figure NOISE FIGURE - dB 6.0 5.0 4.0 3.0 2.0 1.0 12.0 OUTPUT POWER - dBm 33.0 18.0 Power Output at 1 dB Compression AKT18121 32.0 Typical Performance 31.0 30.0 29.0 28.0 27.0 12.0 90 INTERCEPT POINT - dBm 13.0 13.0 14.0 15.0 FREQUENCY - GHz 16.0 17.0 18.0 Intercept Point 80 2nd HAR 70 IP2 60 50 IP3 40 30 12.0 13.0 14.0 15.0 FREQUENCY - GHz 16.0 17.0 18.0 408-522-3838 • Fax: 408-522-3839 • Check for updates: www.teledyne-cougar.com Icc=1856.0 REV/ISO dB -62.12 -71.90 -81.52 -63.27 -74.97 -67.61 -73.79 -70.50 -64.87 -69.07 -62.65 -69.38 -71.66 -63.37 -68.26
Embed!
Akt18121 - Teledyne Cougar