Transcript
3GS/APLEX CENTRAL STATION AUTOMATION LIBRARY MESSAGES All STATUS ALERT messages and MODE SELECTION messages are sent to the automation computer. The R6500 format doesn't allow for a distinction between these two message types and therefore both are transmitted as standard Zone Alarm messages. In the Aplex/Midiplex/ Directplex panels, the original library used zones 9Chex (decimal 156) through to FFhex (decimal 255). With the introduction of the 3GS panel, an expanded library is now necessary starting at 21hex (decimal 33) and in addition security zones 156 to 200 now conflict with the old library. Consequently we have created a new identifier (L & E) to allow the complete library to be accessed as a common resource. APLEX text phrases have been pre-programmed in the Model 4100/4300 Receiver as zone numbers 9Chex (Decimal 156) through to and including FFhex (Decimal 255). The extra 3GS text phrases have been programmed as zone number 21hex (Decimal 33) to zone number 45hex (Decimal 69). The SUITEPLEX text phrases remain as zone alarms associated with the main concierge account and do not use the L & E identifier. They continue to use the A & R identifier and have been pre-programmed as zone numbers 9hex (Decimal 9) to 90hex (Decimal 144). The following table lists the zones and messages for 3GS, Aplex ,Midiplex, Directplex, and Transponders. HEX DECIMAL LIBRARY MESSAGE CODE CODE 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
MODE 6 MODE 7 MODE 8 MODE 9 AREA SETUP CARD INFO FORCE CALL SET UP DM 1200 NODE CONFIGURE OUTPUT TEST COMMS TEST (VERSION 4 PANEL) SOAK MODE COMMAND MODE FAULT ON EXIT SETUP CARDS PAGER TEST NODE/CABINET TAMPER NODE LOST NODE PORT 1 OFFLINE
Page 1 of 7
U U U U U U U U U U U U U S U U S S S
3GS, APLEX, MIDIPLEX, DIRECTPLEX and TRNSPNDR LIBRARY MESSAGES cont. HEX DECIMAL LIBRARY MESSAGE CODE CODE
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45
52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69
NODE PORT 2 OFFLINE NODE RESET MEMORY ERROR POWER/FUSE FAIL DUPLICATE SERIAL # NETWORK RECONFIGURED DATA CHANGED CABLE FAULT HOLIDAY ACCESS MSG DOOR FORCED ACCESS SETUP DOOR HELD PIN CODE ALERT ANTI-PASS BACK ACCESS DENIED DOOR/CARD NOT ASSIGNED INVALID PIN/TIME ZONE
S S S S U U U S S S U U U U U U U U
57
87
UNKNOWN 3GS LITERAL
S
64
100
ACCOUNT OFFLINE/ONLINE
S
9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8
156 157 158 159 160 161 162 163 164 165 166 167 168
DISARMED PART ARMED 1/AUDIBLE SIL 1 PART ARMED 2/AUDIBLE SIL 2 FULLY ARMED DOOR ACCESS/BELL TEST NEW CLOSING TIME ACKNOWLEDGE/CLEAR DISPLAY SYSTEM LOG SHUNT MODE SET DATE/TIME USER SET OWN ID ASSIGN ZONES/VARS. SET IDS/OPTIONS
U U U U U U U U U U U U U
Page 2 of 7
3GS, APLEX, MIDIPLEX, DIRECTPLEX and TRNSPNDR LIBRARY MESSAGES cont. HEX DECIMAL LIBRARY MESSAGE CODE CODE A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA
169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
SERVICE MODE DISABLE MODE LITERAL EDIT *IMPROPER CLOSING* *EARLY OPENING* SHUNTED ZONES= COLD START WARM START HOT START AUTO START P.CODE START SOFT START * MONITOR ALARM * DATE ROLLOVER *CABINET TAMPER* *REMOTE HEAD TAMPER* DO NOT USE BACK TAMPER AC POWER FAIL LMTC DATA PROBLEM LMTC CONTROL PROBLEM LOOKUP MSG 1/O/P 3 OVERLOAD LOOKUP MSG 2/O/P 4 OVERLOAD *FUSE 2 BLOWN* *BATTERY PROBLEM* COMMS TEST *TELCO LINE FAULT* CANNOT ARM SET TIME COMMANDS INPUT OVERFLOW HOUR CHNGE ON SUNDAY *ID SECURITY ALERT* CLEAR DISABLES WALKTEST
Page 3 of 7
U U U S S S S S S S S S S S S S S S S S S S S S S S U S U S U U
3GS, APLEX, MIDIPLEX, DIRECTPLEX and TRNSPNDR LIBRARY MESSAGES cont. HEX DECIMAL LIBRARY MESSAGE CODE CODE CB CC
203 204
-DE E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF
222 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
CODE ENTRY TIME-OUT PRE-PROGRAMMD SHUNT
S U
ZONE TYPES (not txd.)
-
OUT OF SERVICE TIME ADVANCE *ZONE TAMPER ALARM* ** PANIC ALARM** **INTRUDER ALARM** ** FIRE TROUBLE ** **FIRE ALARM** ++ CALL SERVICE ++ **DURESS ALARM** *FIRE DOOR OPENED* *SLOW ENTRY ALARM* *CALL NOT ANSWERED* ----CLOSING TIME SOON PAST CLOSING TIME! POLL TIME = DOOR CHIME ON *SPRINKLER TROUBLE* *SPRINKLER SUPERVY* SET DATA FORMAT ACCESS CONTROL SYNTAX ERROR CANCEL HOUR CHANGE STACK ERROR LOG DATA LOSS! LIT DATA LOSS!
U U S S S S S S S S S S S S S U U S U S S S
EXPLANATION The above codes are either of two types, a STATUS ALERT message or a USER SELECTION message. For example, Library Code A4 hex or 164 decimal indicates that a user selected the SHUNT MODE. The R6500 format does not allow the user number to be included, so we can only tell that the MODE was selected and cannot tell who the user was. In the majority of instances this
Page 4 of 7
EXPLANATION cont. event will be logged only and no action will be taken. The computer automation package must be configured to provide the appropriate response for the code. For example, Library Code C1 hex or 193 decimal is an Alert Message indicating a bad or missing battery in the Subscriber's Control Panel. Normally this message would require a response from the Central/Monitoring Station and therefore the automation software zone information must be entered accordingly. Note that library messages will be preceded by an 'A' if the station does not monitor the 200 zone 3GS panel or an 'L' if the station does monitor 200 zone 3GS panel. SUITEPLEX LIBRARY MESSAGES The following table lists the zones and messages for the SUITEPLEX system. Note that these library messages are always preceded by an 'A' regardless of the setup for the 200 zone 3GS panel. HEX DECIMAL LIBRARY MESSAGE CODE CODE
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DISARM HOME ARM SLEEP ARM FULL ARM BATTERY TEST MODE 6 MODE 7 MODE 8 SERVICE SET-UP EDIT SUITE NAME LITERAL OPTIONS SYSTEM LOG SYSTEM/USER SET-UP MESSAGE OPTION SET DATE & TIME CHANGE OPTIONS
U U U U S U U U U U U U U U U U
2B 2C
43 44
MAINTENANCE CODE MAINTENANCE OPTIONS
U U
2E
46
VIEW LOG
U
32 33
50 51
SET-UP VARIABLES SET-UP ZONES
U U
Page 5 of 7
SUITEPLEX LIBRARY MESSAGES cont. HEX DECIMAL LIBRARY MESSAGE CODE CODE
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
37
55
USER SET-UP
U
39 3A
57 58
VIEW MESSAGE CLEAR MESSAGE
U U
3C
60
SET DATE/TIME
U
45 46
69 70
IMMEDIATE COMMAND EDIT LITERAL
U U
4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A
77 78 79 80 81 82 83 84 85 86 87 88 89 90
ACKNOWLEDGE ALARMS COLD START WARM START HOT START AUTO START P.CODE START SOFT START AC MAINS FAILURE CONC CABINET TAMPER COMMS FAULT SUITE OFF-LINE SUITE ON-LINE SUITE CABINET TAMPER SUITE POWER
U S S S S S S S U S S S U S
5E
94
CANCEL HOUR CHANGE
U
60 61
96 97
USER ACCESS DENIED INVALID USER CODE
U U
65 66 67 68 69 6A 6B
101 102 103 104 105 106 107
HOUR CHNG ON SUNDAY ALARM CANCEL *TECHNICAL ALARM* FUSE 1 BLOWN FUSE 2 BLOWN BATTERY PROBLEM SUITE COMMS RETRIES
U U S S S S S
Page 6 of 7
SUITEPLEX LIBRARY MESSAGES cont. HEX DECIMAL LIBRARY MESSAGE CODE CODE
CONTEXT: U=User Selection, S=Status Alert - = Not Transmitted
6C
108
** CO DETECTOR **
S
80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91
128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145
SYNTAX ERROR STACK ERROR ** FIRE ALARM ** ** INTRUDER ALM ** ** POLICE ALARM ** ++ FIRE TROUBLE ++ ** MEDICAL ALARM ** ** PANIC ALARM ** * ENTRY/EXIT ALARM * * ZONE TAMPER ALRM * CONCIERGE COMMS FAULT LOG ERROR LIT FILE ERROR ** DURESS ** IN USE TOO LONG EXIT USER FUNCTION SERIAL PARAMETERS NOT AVAILABLE
S S U S U S U U S S S S S U U U U U
Page 7 of 7