Transcript
MEASUREMENT INSTRUMENTS
ALP44
“2 Lines, 4 Digits Programmable Projection”
4 ms Sampling Time 2 pcs Relay Outputs (Single and Double Contact) Adjustable Output Times Automatic Calibration Hysteresis TARE Function (ABS/REL Reset) Offset Value Password Protection
ALP 44-P series, 4 digits programmable measuring of displacement and angle by means of linear or rotary potentiometers. ALP 44- V series, measures instruments for 0-10 VDC voltage inputs. ALP 44-A series, measures instruments for 0/4-20 mA current inputs. Mechanical Dimensions
Technical Specifications
48 mm
48 mm
Power Supply
24 VAC/DC 50/60 Hz Optional 24VDC / 24 VAC
Power Consumption
5,5 VA /4,4 W Maximum
Sensor Power Supply
5 VDC 100 mA (Potentiometer) 24 VDC 50 mA (Pressure, Distance sensors)
Wiring
2,5 mm2 Socket Terminal
Inputs
Potentiometer Input (ALP 44-P) 0-10V Voltage Input (ALP 44-V) 0 / 4-20 mA Current Input (ALP 44-A)
Outputs (Relays)
2 pcs 250 VAC 3A (For resistive load) Relay
Dimensions
48 x 48 x 96 mm
Weight
200 grams
Relative Humidity
Up to 31 °C %80, above 31 °C linear decreasing and at 40°C %50 -10 to 60 °C
Storage Temperature
0 to 50 °C
Operating Temperature Protection Class
IP60 Front Panel, IP20 Rear Panel
Connection
OUT-1 OUT-2
9
NO
3
10
COM
4
11
NO
5
12
NC
6
13
COM
7
14
Span Adjustment Outputs 0-10V, 4-20mA or RS232 TX Output 0V (GND) +24 V Sensor Supply 0-10V Input 0V (GND)
+ in -
2
-
8
+
1
-
L N
These outputs are optional. +
Power Supply 24 VAC / DC or 85 / 265 VAC
ALP44-P
ALP44-V
+24 V Sensor Supply 4-20mA Input 0V (GND) ALP44-A
Atek Sensor Technology A.S. Tuzla Kimya Sanayicileri Org. San. Bolg. Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY Tel: +90 216 399 44 04 Fax: +90 216 399 44 02 www.ateksensor.com
[email protected]