Catalog Number Notes Type
S-SERIES LED Lamps
ALSP30 PAR 30 LED Lamp SPECIFICATION GRADE
FEATURES & SPECIFICATIONS
INTENDED USE Ideal for track, recessed and accent lighting use in both commercial and retail applications.
LISTING UL and C-UL Listed to U.S. and Canadian safety requirements. Damp location listed. Tested in accordance with IESNA LM-79 standards. Suitable for use in totally enclosed fixtures per UL1993.
CONSTRUCTION Housing: High quality, cast aluminum, advanced thermal design for optimal cooling efficiency. Optics: Optimally engineered specular faceted reflector for efficient distribution.
WARRANTY Five-year limited warranty. Complete warranty terms located at: http://www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
EXPECTED LIFE 50,000 hours. Max. Luminous Intensity: 3200cd (530L)
DIMENSIONS Diameter: 3-3/4” Length: 3-7/8” Weight: 0.535lbs
LUMEN OUTPUT 530 lumens (530L) Operating Temperature: -22°F to 104 °F (-30 °C to +40 °C) Color Temperature (CRI): 2800K (82CRI); 4000K (85CRI)
All dimensions are inches.
ELECTRICAL SYSTEM Uses High Brightness LED mounted to efficient thermal transfer system. 15-watt (530L) high efficiency integral driver 110-120VAC. Actual wattage may differ by +10%/-15% when operating between 110-120V +/- 10%. Dimmable down to 10%.
Note: Specifications subject to change without notice. Actual performance may differ as a result of end-user environment and application.
ORDERING INFORMATION
Example: ALSP30 530L DIM
For shortest lead times, configure products using bolded options. LED LAMP Series ALSP30
Lumen output1 PAR 30 LED Lamp
530L 15W, 530 lumens
Beam Angle (blank)
25 degrees
Color temperature (blank) 40K
2800K 4000K
Base (blank)
Dimming E26 base
DIM
Dimmable
Notes 1 Total system delivered lumens.
See page 2 for Photometric Date
Page 1 of 3
ALSP30 — PAR 30 LED Lamp SPECIFICATION GRADE
PHOTOMETRICS
0
80º
80º
750 60º
60º
1500 40º
40º
2250 3200 20º
0º
20º
LED REPLACEMENT CHARTS Halogen Product Lumens Watts Beam Spread Candela CCT CRI Life
ALSP30 530L 530 15W 25 3200 2800K/4000K 85/92 50,000 hours
630 1030 50W 75W 12 13 2300 3800 2800K 2830K 100 100 3,000 hours
SHEET# ALSP30 — PAR 3O LED LAMP (S-SERIES) LAMPS AND TRACK: One Lithonia Way Conyers, GA 30012 Phone: 800.533.7728 Fax: 770-918-1209 www.acculamp.com
Page 2 of 3
© 2010-2012 Acuity Brands Lighting, Inc. All rights reserved. Rev.12/10/13
ALSP30 — PAR 30 LED Lamp SPECIFICATION GRADE
LED LAMP AND DIMMER COMPATIBILITY Mfg
Cat No.
Acuity Brands - Sensor Switch Acuity Brands - Synergy Leviton Leviton Leviton Leviton Leviton Leviton Leviton Leviton Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron ELV Digital Fade Lutron Graphic Eye QS Lutron Graphic Eye QS Lutron Graphic Eye QS Lutron HomeWorks QS Lutron RadioRA2 Neptun
nLight NSP5 PCD ELV 120 ISDELV400120WH 6633-P 6681 IPIO6 6613-P 6631-LW 6161-I RPIO6-1 IPE04-1LZ TG-603P TG-600P AY-103P DV-600P DVCL-153PD S-600P C-L wall mount Dimmers MRF2-6ELV PHPM-PA PHPM-WBX 3 wire fluorescent Main unit family HQRD-6NA RRD-6NA Apollo 80005
Dimming Method
Wattage
Reverse Phase Reverse Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Reverse Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Forward Phase Reverse Phase Reverse Phase Reverse Phase Forward Phase Neutral Adaptive Phase Adaptive Forward Phase
480W 400W 600W 600W 600W 600W 600W 500W 600W 400W 600W 600W 1000W 600W 600W 600W 600W 600W 1920W 1920W
Note: Most forward phase dimmers have a minimum load requirement of 40-60 watts. A single 15W watt LED lamp on a 600W dimmer may flicker if the minimum load requirement is not met, consider a synthetic minimum load, LUTRON-LBX or other equivalent. This requires a 2-gang wall box and additional wiring to the dimmer.
Comments maximum load
Depending on the quantity of LED lamps on the dimming circuit, an approximate 10% to 100% dimming range may be obtainable. Most available dimmers were designed around older technology and resistive or incandescent lamp loads, therefore performance can vary with LED load and is not guaranteed. Please see the manufacturer’s instructions on dimmers for use with LED lamps and do not exceed the 150W LED load for 600W rated dimmer.
Adjust low end trim Adjust low and high end trim. 10W min load Adjust low and high end trim.
600W 600W 600W
Acculamp LED–20 Amp Circuit Load
Use the table (right) as a guide, for the approximate quantity of Acculamp LED lamps on a typical standard 20-amp circuit (derated to 80% - 16 amps). Use a licensed electrician to determine proper wire gauges and circuit breakers according to the National Electrical Code and local codes. Do not overload circuit with more lamps than the approximate quantity shown below for a typical standard 20-amp circuit breaker for approximately 7X multiple of inrush current. Circuit breakers with higher inrush trip curve characteristics, such as High Magnetic types, are available. Consult with a licensed electrician for proper determination.
Lamp Model ALSP30 530L DIM ALSP30 530L 40K DIM
Wattage 15W 15W
Operating Amps Approx. Quantity .180 .180
SHEET# ALSP30 — PAR 3O LED LAMP (S-SERIES) LAMPS AND TRACK: One Lithonia Way Conyers, GA 30012 Phone: 800.533.7728 Fax: 770-918-1209 www.acculamp.com
23 23
Page 3 of 3