Transcript
A Altevo FS4500/FS4100
Cost-effective, scalable Fiber Channel to SATA RAID solution
eSlim Korea Storage Product Series 1
AGENDA 1. Product Overview 2. Component Details 3. Architecture 4. Configurations 5. Performance
2
Product Overview
ESLIM
3
KOREA
INC
Product Overview – Front & Rear View
12
9
6
3
11
8
5
2
10
7
4
1
2U Height
APC Modules (Advanced Power & Cooling )
RAID I/O Modules ES Module (Environmental Services )
JBOD I/O Modules
4
Product Highlights
FS-4500 RAID --Dual Dualactive, active,failover/failback failover/failback레이드 레이드컨트롤러 컨트롤러 provide up to 48,000 I/Os and 385MByte/sec provide up to 48,000 I/Os and 385MByte/sec --No NoSingle Singlepoint pointofoffailure failurewith withredundant, redundant, hot-swappable components hot-swappable components --최대 최대96개의 96개의드라이브 드라이브탑재, 탑재,24TB 24TB공간지원, 공간지원, 랙마운트(Rackmount) 또는 페데스탈(Pedestal) 랙마운트(Rackmount) 또는 페데스탈(Pedestal)구성 구성 --각 각드라이브의 드라이브의듀얼 듀얼포트 포트엑세스를 엑세스를위해 위해독립적으로 독립적으로 고안된 Mutliplexor Technology 고안된 Mutliplexor Technology --직관적 직관적및 및편의성이 편의성이돋보이는 돋보이는RAIDWatch RAIDWatch매니지먼트 매니지먼트 소프트웨어 소프트웨어 --추후 추후3Gb 3GbSATA를 SATA를지원하는 지원하는Midplane Midplane --비용 효율이 높은 싱글 컨트롤러 비용 효율이 높은 싱글 컨트롤러또는 또는안정성 안정성및 및 고가용성을 고가용성을 위한 위한듀얼 듀얼 컨트롤러 컨트롤러구성 구성 --컨트롤러당 최대 1GB의 캐시 메모리 컨트롤러당 최대 1GB의 캐시 메모리지원 지원 ((Total Total2GB 2GB)) --컨트롤러당 컨트롤러당2개의 2개의호스트 호스트포트, 포트,시리얼, 시리얼,이더넷, 이더넷, 확장포트 확장포트지원 지원 5
FS-4100 JBOD --Dual Dualactive, active,failover/failback failover/failback지능형 지능형컨트롤러 컨트롤러 provide up to 350MByte/sec provide up to 350MByte/sec --No NoSingle Singlepoint pointofoffailure failurewith withredundant, redundant, hot-swappable components hot-swappable components --최대 최대96개의 96개의드라이브 드라이브탑재, 탑재,24TB 24TB공간지원, 공간지원, 랙마운트(Rackmount) 또는 페데스탈(Pedestal) 랙마운트(Rackmount) 또는 페데스탈(Pedestal)구성 구성 --각 각드라이브의 드라이브의듀얼 듀얼포트 포트엑세스를 엑세스를위해 위해독립적으로 독립적으로 고안된 Mutliplexor Technology 고안된 Mutliplexor Technology --직관적 직관적및 및편의성이 편의성이돋보이는 돋보이는매니지먼트 매니지먼트소프트웨어, 소프트웨어, Storage Examiner Storage Examiner --추후 추후3Gb 3GbSATA를 SATA를지원하는 지원하는Midplane Midplane --비용 효율이 높은 싱글 컨트롤러 비용 효율이 높은 싱글 컨트롤러또는 또는안정성 안정성및 및 고가용성을 고가용성을 위한 위한듀얼 듀얼 컨트롤러 컨트롤러구성 구성 --유연한 구성을 위해 컨트롤러당 4개의 유연한 구성을 위해 컨트롤러당 4개의SFP SFP커넥션 커넥션 --독립형 독립형JBOD JBOD또는 또는FS4500 FS4500FC-to-SATA FC-to-SATARAID의 RAID의 확장형 JBOD 구성 확장형 JBOD 구성
Technical Specifications FS-4500 System
( Ordering Part Number : FS4500SR-AC )
Host HostInterface Interface --One or One ortwo twoFiber FiberChannel Channelcontrollers controllers; ; each eachcontroller controllersupports supportsdual dualoptical opticalor orcopper copper(SFP) (SFP) connections, connections,200MB/s 200MB/seach each(400MB/s (400MB/stotal) total) --Serial (RS232) port, Ethernet port, Serial (RS232) port, Ethernet port, copper copperor oroptical optical(SFP) (SFP)expansion expansionport port Disk DiskDrive DriveInterface Interface --Independent Independent150MB/s 150MB/spoint-to-point point-to-pointconnections connectionstoto each eachSATA SATAdisk diskdrive drivewith withdual dualport portaccess accessand and failover failoverby byeach eachcontroller controllertotoeach eachdrive drive Measured MeasuredPerformance Performance((Dual DualControllers, Controllers,RAID-5 RAID-5)) --Up Uptoto385MB/s 385MB/s(sustained (sustainedreads), reads), 48,000 I/Os (cached reads) 48,000 I/Os (cached reads) RAID RAIDController ControllerSpecifications Specifications --PowerPC 750 667 PowerPC 750 667MHz MHzRISC RISCprocessor processor --Hardware XOR Hardware XOR --Up Uptoto1GB 1GBMemory Memoryper percontroller controller --4MNB flash memory 4MNB flash memory --ECC ECCmemory memorysupport support
6
Controller ControllerFeatures Features --Dual active Dual activewith withautomatic, automatic,transparent transparentfailover/failback failover/failback --Auto-negotiate speeds Auto-negotiate speeds --In-band In-bandand andout-of-band out-of-bandmanagement management --Replacement Replacementcontroller controllerreflashes reflashesFW FWtotomatch matchpeer peer controller controller --Selective SelectiveLUN LUNdeletion deletion --LUN LUNMasking Masking––up upto to128 128LUNs LUNsand and1024 1024host hostports ports supported supported --F_port F_portand andFL_port FL_portsupport support --Cache Cachecoherency coherency --Battery protected Battery protectedmirrored mirroredwrite writecache cache --Write through, write back, or read-ahead Write through, write back, or read-aheadcache cachesupport support per perlogical logicaldrive drive --Variable cache Variable cacheline linesize sizeand andstripe stripesize size --Dedicated controller-to controller communication Dedicated controller-to controller communicationpath path --Background disk scrubbing and data integrity checking Background disk scrubbing and data integrity checking --Concurrent ConcurrentRAID RAIDlevel levelsupport support––0~5, 0~5,10, 10,30, 30,50 50 --Each logical drive can have an independent RAID Each logical drive can have an independent RAIDlevel level --On-line RAID group expansion/partitioning On-line RAID group expansion/partitioning --Up Uptoto32MB 32MBI/O I/Orequest requestsizes sizes --Global hot spare drives assign Global hot spare drives assignaaspare sparetotoaaspecified specifiedLUN LUN --Write through/back configurability per LUN Write through/back configurability per LUN --Write Writethrough throughperformance performanceoptimization optimization
Technical Specifications FS-4100 System
( Ordering Part Number : FS4100SR-AC )
Host HostInterface Interface --One or One ortwo twoFiber FiberChannel Channelcontrollers controllers; ; each eachcontroller controllersupports supportsup upto tofour fouroptical opticalor orcopper copper (SFP) (SFP)connections, connections,200MB/s 200MB/seach each(800MB/s (800MB/stotal) total) --Port can be used for host connections or as a Port can be used for host connections or as a combination combinationofofhost hostconnection connectionand andexpansion expansion --Serial (RS232) port, Ethernet port, Serial (RS232) port, Ethernet port, Disk DiskDrive DriveInterface Interface --Independent Independent150MB/s 150MB/spoint-to-point point-to-pointconnections connectionstoto each eachSATA SATAdisk diskdrive drivewith withdual dualport portaccess accessand and failover by each controller to each drive failover by each controller to each drive Measured MeasuredPerformance Performance --Up to 350MB/s Up to 350MB/s(sustained (sustainedreads) reads) Intelligent IntelligentController ControllerSpecifications Specifications --PowerPC 440 400 MHz PowerPC 440 400 MHzRISC RISCprocessor processor --128MB memory per controller 128MB memory per controller --ECC ECCmemory memorysupport support
7
Controller ControllerFeatures Features --Dual active Dual activewith withautomatic, automatic,transparent transparentfailover/failback failover/failback --Auto-negotiate speeds Auto-negotiate speeds --In-band In-bandand andout-of-band out-of-bandmanagement management --Replacement Replacementcontroller controllerreflashes reflashesFW FWtotomatch matchpeer peer controller controller --F_port F_portand andFL_port FL_portsupport support --Dedicated Dedicatedcontroller-to controller-tocontroller controllercommunication communicationpath path
Technical Specifications FS-4500 & FS-4100 공통 Capacity Capacity --Up Uptoto12 12drives drives(3TB) (3TB)capacity capacityper per2U 2Uenclosure enclosurewith with aatotal maximum of 96 drives (24TB) capacity per total maximum of 96 drives (24TB) capacity per subsystem subsystem Redundant, Redundant,Hot-swappable Hot-swappableComponent Component --Up to two RAID controllers Up to two RAID controllers --Two Twoindependent independentAC ACpower powerinlets inlets --Two advanced power and cooling Two advanced power and coolingmodules modules(APC) (APC) --Enclosure services module Enclosure services module --Up Uptoto12 12drives drives --No active No activecomponents componentson ondata datapath path Maximum MaximumCable CableLengths Lengths --Optical : Up to 23 Optical : Up to 23meters meters --Copper : Up to 6 meters Copper : Up to 6 meters Pedestal PedestalCabinet CabinetDimensions Dimensions --49.53 x 11.7 x 54.6 49.53 x 11.7 x 54.6mm mm(WxHxD), (WxHxD),27kg 27kg Rackmount Rackmountenclosure enclosuredimensions dimensions --8.9 x 44.7 x 49.53 mm (WxHxD), 8.9 x 44.7 x 49.53 mm (WxHxD),27kg 27kg
8
Monitoring Monitoring --Temperature, Temperature,advanced advancedpower powerand andcooling coolingmodules modules including fan speed control, disk drives, and including fan speed control, disk drives, andI/O I/Omodules modules Failure FailureNotification Notification --SCSI enclosure SCSI enclosureservices services(SES) (SES)over overI2C I2Cphysical physicalinterface interface , ,LEDs, audible alarms, FRU (Field Replaceable Unit) LEDs, audible alarms, FRU (Field Replaceable Unit) reversion reversionand andserial serialnumber numberreporting, reporting,events eventsreported reported totoRAIDWatch software RAIDWatch software AC ACPower Power --Input Inputvoltage voltage: :Autoranging, Autoranging,85~264 85~264VAC VAC --Input current : 100~240 VAC @ 4~25 Input current : 100~240 VAC @ 4~25AA --Output Outputpower power: :491W 491Wpeak, peak,430W 430Waverage average Operating OperatingEnvironment Environment --Temperature Temperature: :0℃ 0℃~~40 40℃ ℃ --Relative Humidity : 50% ~ Relative Humidity : 50% ~95% 95%(non-condensing) (non-condensing) Software Software RAIDWatch RAIDWatch --Local Localor orremote remotemanagement, management,monitoring, monitoring,and and configuration with host platform support for configuration with host platform support for Microsoft MicrosoftWindows, Windows,Sun SunSolaris SolarisSPARC, SPARC,and andLinux Linux
Product Overview – FS-4XX0 SATA Platform
33 Versions Versions of of the the Fiber Fiber Channel Channel to to SATA SATA Platform Platform with with Multiple Multiple I/O I/O Options Options FS 4500
FS 4100
FS 4050
12 12 1” 1”SATA SATADisk DiskDrives Drives SATA SATA3Gb 3Gbready ready––downward downwardcompatible compatibleto toSATA SATA1.5Gb 1.5Gb 2 SES Interface SES(SCSI (SCSIEnclosures EnclosuresServices) Services)via viaII2CCInterface
2Gb 2GbFiber Fiberto toSATA SATARAID RAID
2Gb 2GbFiber Fiberto toSATA SATAJBOD JBOD
--Dual DualPort PortMultiplexer Multiplexer(MUX) (MUX)card cardfor forhigh highavailability availability configurations configurations --Single Singleor orDual DualI/O I/OModules Modules 9
Cost-effective Cost-effective 2Gb 2GbFiber Fiberto toSATA SATAJBOD JBOD
Single SingleChannel ChannelI/O I/OProcessor, Processor, Can’t be upgraded to Can’t be upgraded todual dualcontroller, controller, different differentbackplane, backplane,No NoMUX MUX
Component Details
ESLIM
10
KOREA
INC
Component Details - Enclosure Indicate LED
LED 1 LED 2 LED 3 LED 4
11
Enclosure LED Descriptions Function LED 1
OFF : Power Off ON : Power On
LED 2
ON
LED 3
1.5 / 3.0 Gigabit Operation LED
LED 4
Not used
: Shelf Fault
Component Details - Disk Drive LED
Bicolor Information Green
Drive Carrier LED Functions Indication LED1
LED2
LED3
12
Comments
Not Used
Not Used
Bicolor Green/Amber Drive Detect/Error
This LED is driven by the ES module. Green indicates drive detected Amber flashing indicates drive error per SES specification OFF indicates no drive detected
Green Drive I/O Activity
ON indicates drive activity OFF indicates no drive I/O activity
Amber
Condition
OFF
OFF
Slot empty, ready for insert/remove
ON
OFF
Drive online
ON
OFF
Prepare for operation
ON 125ms OFF125ms
OFF OFF
Drive identify/special POD identify
ON 250ms OFF250ms
OFF OFF
Prepare for removal
ON 500ms OFF125ms
OFF OFF
Drive rebuild
OFF OFF
ON 125ms OFF125ms
Drive fail
OFF OFF
ON 125ms OFF750ms
Drive offline
ON 500ms OFF500ms OFF1000ms
OFF500ms ON 500ms OFF1000ms
Predicted failure
Component Details - APC
Advanced Power and Cooling module --Integrated Integratedpower powersupply supplyand andcooling coolingmodule module --Power Supply Power Supply Input InputVoltage Voltage: :Autoranging, Autoranging,85~264 85~264VAC VAC Input Frequency : 47~63 Hz Input Frequency : 47~63 Hz Input InputCurrent Current: :100~240 100~240VAC VAC@ @4~2.5A 4~2.5A Output Power : 491W peak, 430W Output Power : 491W peak, 430Waverage average --Cooling Cooling 33variable variablespeed speedfans fansper perAPC APC((66inintotal total)) 20 20CFM CFMper perfan fan N+1 N+1redundancy redundancy––requires requiresminimum minimumof of55fans fans 13
Component Details – ES module
Environmental Services module --Reports Reportsstatus statusand andreceives receivescontrol controlinformation informationvia viaan anI2C I2Cbus busto tothe theI/O I/Ooption optionmodule module --Monitoring/control Monitoring/controlfor forthe theadvanced advancedpower powerand andcooling coolingunits units --Controls ControlsFRU FRUstatus statusLEDs LEDsand andglobal globalaudible audiblealarm alarm --ES ESprocessor processoramber amberLED LEDtotodenote denoteES ESprocessor processorfault fault --Reporting Reportingcapability capabilityofofPSU, PSU,I/O I/Omodule, module,ES ESmodule, module,and andbackplane backplaneserial serialnumber numberand andrevision revision --Hot-swappable Hot-swappablewithout withoutaffecting affectingthe thedata datapath path --Micro-controller Micro-controllerfor fordata dataprocessing, processing,control, control,and andcommunications communications --Housing Housingalso alsocontains containsthe theshelf shelfID IDswitch switch––each eachshelf shelfmust musthave haveunique uniqueID IDwhen whendaisy daisychained chained
14
Component Details – RAID Module
FS4500 FC/SATA RAID Controller --Single Singleand anddual dualcontroller controllerconfigurations configurations Active-active, Active-active,automatic automaticfailover, failover,hot-swappable hot-swappable --PowerPC PowerPCmicroprocessor microprocessorplus plushardware hardwareXOR XORRAID RAIDengine engine RAID RAIDlevels levels0,0,1,1,0/1, 0/1,3,3,5,5,10, 10,30, 30,50 50 --Up Uptoto1GB 1GBofofECC ECCcache, cache,battery batterybacked-up backed-upper percontroller controller --Two Two2Gb 2Gb(SFP) (SFP)Fiber FiberChannel Channelhost hostinterfaces interfacesand andone one2Gb 2Gb(SFP) (SFP)expansion expansionport portper percontroller controller --10/100BaseT 10/100BaseTport portfor formanagement managementper percontroller controller --LEDs LEDsfor forstatus status --RS232 RS232port portfor forconfiguration configurationand anddiagnostics diagnosticsper percontroller controller
15
Component Details – RAID Module LEDs
D1
............
D7 D8-1
LED
Color
Designation
D1
Green
FC Host 1 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on FC Host port 1.
D2
Green
FC Host 2 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on FC Host port 2.
D3
Green
FC Disk Expansion Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on the FC Disk Expansion port.
D4
Green
Controller Ready
This LED is ON when the controller is active and operating properly
D5
Green
FC Host Ports Active
ON indicates activity on the FC host ports
D6
Green
SATA Device (Drive) Ports Active
ON indicates activity on the SATA disk drive ports
Partner Failed
ON indicates that the partner controller has been detected as failed. OFF indicates that the partner controller is operating properly. In the case of a signal controller installed in the shelf, this LED will be OFF
Cache/BBU Fault
ON indicates Cache memory & Backup statues OFF indicates that the battery backup unit is capable of sustaining memory in case of power loss.
D7
D8-1
16
D2
Amber
Amber
Description
Component Details – JBOD module
FS4100/FS4050 FC/SATA JBOD Controller --Single Singleand anddual dualcontroller controllerconfigurations configurationswith withfailover failover --RAID RAID00and and1( 1(future futurefirmware firmwarerelease release)) --128 128MB MBofofECC ECCmemory memory --Four Four2Gb 2Gb(SFP) (SFP)Fibre FibreChannel Channelinterfaces interfacesper percontroller controller --22host hostconnections connectionsand and22expansion expansionports portsor or44host hostconnections connections --LEDs LEDsfor forstatus status --RS232 RS232port portfor forconfiguration configurationand anddiagnostics diagnostics
17
Component Details – JBOD module LEDs
1357 2368
18
LED
Color
Designation
Description
1
Green
FC Host Ports Active
ON indicates activity on the FC host ports.
2
Green
FC Host 1 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on FC Host port 1.
3
Green
SATA Device (Drive) Ports Active
ON indicates activity on the SATA disk drive ports.
4
Green
FC Expansion 1 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on the FC Expansion port 1.
5
Amber
Partner Failed
ON indicates that the partner controller has been detected as failed. OFF indicates that the partner controller is operating properly. In the case of a single controller installed in the shelf , this LED will be OFF.
6
Green
FC Host 2 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on FC Host port 2.
7
Green
Controller Ready
This LED is ON when the controller is active and operating properly.
8
Green
FC Expansion 2 Signal Detect
When ON, this LED denotes that a valid FC signal has been detected on the FC Expansion port 2.
Component Details – Management Software [[Spheras SpherasRAIDWatch RAIDWatch(SRW) (SRW)]] --Remote Remotegraphical graphicalconfiguration configurationand andmonitoring monitoringutility utility --Event Eventnotification notificationthrough throughSNMP SNMPtraps, traps,pager, pager,e-mail e-mail --Easy-to-use, intuitive graphical user interface Easy-to-use, intuitive graphical user interface --Communicates Communicateswith withcontrollers controllersvia viaout-of-band out-of-bandtransmission transmissionover overEthernet Ethernetor orin-band in-bandover overHost HostFiber FiberChannel Channel --Runs in stand-alone model or remotely over LAN/WAN using any standard web browser via hybrid TCI/IP Runs in stand-alone model or remotely over LAN/WAN using any standard web browser via hybrid TCI/IPchannel channel
RAIDWatch RAIDWatch Manager
RAID Storage
19
Primary Agent
Secondary Agent
Architecture
ESLIM
20
KOREA
INC
Architecture – RAID Controller Block Diagram
Up to 1GB
133 MHz, 64-bit Memory Bus
PowerPC 133 MHz, 64-bit Bus, 1064 MB/sec
750Cxe
Hardware XOR ASIC 133
8-bit X-Bus
Host
21
NVRAM, Flash, UART, I2C, Misc.
66 MHz, 64-bit PCI 528 MB/sec
66 MHz, 64-bit PCI 528 MB/sec
2Gb FC x2
Data Cache SDRAM w/ ECC
SATA STAx2 x8
SATA x8
Disk Drives
2Gb FC x2 RCC
Architecture – JBOD Controller Block Diagram Data Cache SDRAM w/ ECC 128 MB
133 MHz, 64-bit Memory Bus
PowerPC
NVRAM, Flash, UART, I2C, misc.
PPC440 400 MHz
100 MHz, 64-bit PCIx 800 MB/sec
2Gb FC x2 Host
22
SATA STAx2 x8
SATA x8
Disk Drives
Architecture – Dual Port Multiplexer MUX and Non-MUX --Multiplexor Multiplexorisisused usedwith withSATA SATAdrives drivesto togive giveDual DualPort Portcapability capability --Drive :: FS4500 Drivewith withMUX MUXcard card FS4500&&FS4100 FS4100 --Drive Drivewithout withoutMUX MUXcard card :: FS4050 FS4050 MUX Card
FS4500 Single RAID & FS4050 JBOD
=
Cost-effective - Support Only Single RAID, Can’t upgraded to Dual RAID - Different Backplane
FS4500 RAID & FS4100 JBOD
+ 23
=
- MUX card for High Availability - Support Single or Dual RAID
Architecture – FS4500 Channel Block Diagram
Fiber Channel Host Port 0
Fiber Channel Host Port 1
Fiber Channel Host Port 0 RCCOM Channel (Fiber)
Primary Controller
12 SATA Backend drive channels
Secondary Controller
12 SATA Backend drive channels
Backend Fiber Expansion Channel
.
.
.
.
.
.
.
.
12 X SATA Drives
24
Fiber Channel Host Port 1
All Expansion drives show up in the TUI on channel 2 Backend Fiber Expansion Channel
.
Drive MUX Cards (Only 2 shown)
Architecture – FS4100 Channel Block Diagram
Fiber Channel Host Port 0
Fiber Channel Host Port 1
Fiber Channel Host Port 0
Secondary Controller
Primary Controller
12 SATA Backend drive channels
12 SATA Backend drive channels
2 X Backend Fiber Expansion Channels
.
.
.
.
.
.
.
.
12 X SATA Drives 25
Fiber Channel Host Port 1
2 X Backend Fiber Expansion Channels
.
Drive MUX Cards (Only 2 shown)
Configurations
ESLIM
26
KOREA
INC
Configurations – FS4500 Configuration
Host 1
Host 2
Single Controller Configuration --22Hosts Hostsconnected connectedto toone onecontroller controller --11HBA HBAinin11Host Host
Host 1
Cluster Configuration nd --Add Add22ndcontroller controller for forHigh HighAvailability Availabilityand andperformance performance
--22HBAs HBAsinin11Host Host
27
Host 2
Configurations – FS4100 Configuration
Host 1
Host 2
Host 3
Host 4
Host 1 Host 3
Single Controller Configuration --44Hosts Hostsconnected connectedto toone onecontroller controller --11HBA HBAinin11Host Host
Host 2 Host 4
Host 6
Host 7
Dual Controller Configuration nd --Add Add22ndcontroller controller --88Hosts Hostsconnected connectedto toFS4100 FS4100
--11HBAs HBAsinin11Host Host
28
Host 5
Host 8
Configurations – Daisy Chaining FS4500 to FS4100
Host 2
Host 1
FS4500
Cluster & Daisy Chaining FS4100
--High HighAvailability AvailabilityConfiguration Configuration --Up Upto to88systems systemsdaisy daisychained chained ((FS4500 FS45001set, 1set,FS4100 FS41007sets 7sets)) --Up Upto to96 96drives, drives,24TB 24TB
FS4100
--22HBAs HBAsinin1Host 1Host Further expansion shelves
29
Configurations – Multi-host FS4500 to FS4100
Host 1
Host 2
Host 3
Host 4
FS4500
Multi-host Daisy Chaining --Direct Directattach attachquad quadserver serverconfiguration configuration --Up Upto to88systems systemsdaisy daisychained chained
FS4100
((FS4500 FS45001set, 1set,FS4100 FS41007sets 7sets)) --Up Upto to96 96drives, drives,24TB 24TB
FS4100
--11HBAs HBAsinin11Host Host
Further expansion shelves 30
Configurations – FS4500 SAN Configuration with FS4100 Expansion
Host 1
Host 2
Host 3
Host 4
SAN switch
FS4500
FS4100
FS4100
31
Host n
Performance
ESLIM
32
KOREA
INC
Performance – Test Configuration
Altevo FS4500 Fibre Channel Storage Performance Test Configuration Windows 2003 Standard Edition Qlogic qla2340L 2Gb Single path connection Write-back cache mode Stripe Size : 128KB 250GB SATA 12 Disks : RAID5 and no-Hot-spare Test Software Windows 2003 Standard Edition Iometer-2003-05-10 version : 5 clients
33
Performance – Test Result
Altevo FS4500 2Gb Performance by Iometer under NTFS Sequential Read
Random Read
Sequential Write
Random Write
210 190 173
170
165.3 152.87
150
190.09 189.87 188.5 188.8
190.14 190.04 189.45 189.26
191.03 190.25 189.51 186.55
168.64
154.57 152.48
123.34 113.3
110
70
189.99 186.2 185.82 183.05
144.76
130
90
179.52 178.05 177.56
189.39 188.58 183.45 178.14
100.27 95.75
71.27 64.78
50 8K
16K
32K
64K
Horizon : File Size ( KB )
34
128K
256K
512K
Vertical : Transmit rate ( MB/sec )
1M
10M