Preview only show first 10 pages with watermark. For full document please download

Am-800480r3tmqw-a1h-f

   EMBED


Share

Transcript

AMP DISPLAY INC. SPECIFICATIONS CUSTOMER CUSTOMER PART NO. AMP PART NO. AM-800480R3TMQW-A1+) APPROVED BY DATE  Approved For Specifications  Approved For Specifications & Sample AMP DISPLAY INC 9856 SIXTH STREET RANCHO CUCAMONGA CA TEL: 909-980-13410 FAX: 909-980-1419 WWW.AMPDISPLAY.COM APPROVED BY Date : 2011/08/22 CHECKED BY 1 91730 ORGANIZED BY RECORD OF REVISION Revision Date Page Contents Editor 2010/09/13 - LED life time Kevin 2011/09/05 6 Adjust the LED life time to 40hr Titan Date : 2011/9/5 2 1. Features 7 inch module is a color active matrix thin film transistor (TFT) liquid crystal display (LCD) that uses amorphous silicon TFT as a switching device. This model is composed of a TFT LCD panel, a driving circuit and a back light system. This TFT LCD has a 7.0 (16:9) inch diagonally measured active display area with WVGA (800 horizontal by 480 vertical pixel) resolution. (1) Construction: 7” a-Si TFT active matrix, White LED Backlight. (2) Resolution (pixel): 800(R.G.B) X 480 (3) Number of the Colors : 262K colors ( R , G , B 6 bit digital each) (4) LCD type : Transmissive , normally White (5) Viewing Direction: 6 O’clock ( The direction it’s hard to be discolored ) (6) Interface : LVDS interface (7) Reflective ratio 0.5% ~ 2% 2. PHYSICAL SPECIFICATIONS Item Specifications LCD size Outline Dimension (Include connecter) unit 7 inch (Diagonal) 165.0 x 104.44 x 6.76 (typ.) mm Number of Pixel 800 RGB (H) x 480 (V) pixels Pixel pitch 0.1905 (H) x 0.1905 (V) mm Pixel arrangement RGB Vertical stripe Display mode Surface treatment Normally white Antiglare, Hard-Coating (3H) with EWV film Weight Back-light 150 (typ.) Single LED (Side-Light type) Power consumption (B/L system) Date : 2011/9/5 g 2.4 (max.) 3 W 3. ABSOLUTE MAX. RATINGS 3-1 Electrical Absolute Rating 3-1-1 TFT LCD Module Item Symbol Power voltage VCC Values Voltage range at any terminal UNIT Note 4.0 V GND=0V -0.5 VCC+0.3 V Min. Max. -0.5 3-2 Environment Absolute Rating Item Symbol Min. Max. Unit Operating Temperature Topa -20 70 ℃ Storage Temperature Tstg -30 80 ℃ Date : 2011/9/5 4 Note 4. ELECTRICAL CHARACTERISTICS 4-1 TFT LCD Module Date : 2011/9/5 5 4-2 Backlight Unit Item LED Driver Voltage Power Supply Current For LED Driver ADJ Input Voltage Symbol Min. Typ. Max. Unit VLED - 5 - V Note VLED=5V VADJ=3.3V (duty 100%) duty=100% Note(3) I LED =160mA Ta=25℃ ILED - 380 420 mA V ADJ - 3.3 - V LED voltage VAK -- 9.9 -- V LED current ILED -- 180 -- mA Ta=25℃ -- 135 -- mA Ta=60℃ LED Life Time - -- 40K -- Hour Note (2) Note (1) The constant current source is needed for white LED back-light driving. When LCM is operated over 60 deg.C ambient temperature, the I LED of the LED back-light should be adjusted to 135mA max Note (2) Brightness to be decreased to 50% of the initial value. ILED=180mA A 18mA LED 10 LED 9 LED 3 LED 2 LED 1 …… K LED Light Bar Circuit Note(3) VLEDADJ is PWM signal input. It is for brightness control. ITEM SYMBOL MIN TYP MAX ADJ signal frequency fPWM 100 20K ADJ signal logic level High VIH 2V -- ADJ signal logic level Low VIL 0 -- Date : 2011/9/5 6 30K VLED (5.0V) 0.5 UNIT Hz V V F=~20K Hz H Duty=100% Brightness=100% L H Duty=75% Brightness=75% L H Duty=50% Brightness=50% L H Duty=25% Brightness=25% L H Duty=0% Brightness=0% L Date : 2011/9/5 7 5. Optical Specifications 5-1 Optical specification Item Viewing Angle Symbol Condition Min. Typ. Max. Unit Note deg. (1)(2)(3) Front f 50 60 -- Back b 60 70 -- Left l 60 70 -- Right r 60 70 -- 250 400 -- -- (1)(3) Tr -- 5 10 ms (1)(4) Tf -- 11 16 ms (1)(4) Wx 0.287 0.317 0.347 Wy 0.315 0.345 0.375 0.551 0.581 0.611 0.331 0.361 0.391 Gx 0.324 0.354 0.384 -- (1) Gy 0.534 0.564 0.594 Bx 0.118 0.148 0.178 By 0.094 0.124 0.154 Contrast ratio CR Response Time White Red Color chromaticity Green Blue Luminance Luminance Uniformity Rx Ry CR≧10 Θ=Φ=0° Θ=Φ=0° L Θ=Φ=0° 400 500 -- cd/m2 (1)(5) ΔL Θ=Φ=0° 70 -- -- % (1)(5)(6) Note 1: Ta=25°C. To be measured on the center area of panel after 10 minutes operation. Note 2: Definition of Viewing Angle Date : 2011/9/5 8 Note 3: Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio(CR)= Photo detector output when LCD is at ”White” state Photo detector Output when LCD is at “Black” state Note 4: Definition of response time: The output signals of photo detector are measured when the input signals are changed from “black“ to “white”(falling time) and from ”white” to “black” (rising time) respectively. The response time is defined as the time interval between the 10% and 90% of amplitudes. Refer to figure as below. Note 5 : Luminance is measured at point 5 of the display. Note 6 : Definition of Luminance Uniformity ΔL = [ L(min.) of 9 points / L(max.) of 9 points] X 100% Date : 2011/9/5 9 6. Block Diagram 800 (RGB) x 480 TFT LCD Panel TFT LCD Panel Unit Power Unit and LVDS Unit IN0+, IN0-, IN1+, IN1-, IN2+, IN2- Date : 2011/9/5 CLK+, VCC VLEDADJ CLK- GND VLED 10 7. INTERFACE Pin No. Symbol 1 VDD POWER SUPPLY:3.3V 2 VDD POWER SUPPLY:3.3V 3 GND Power Ground 4 GND Power Ground 5 IN0- Transmission Data of Pixels 6 IN0+ Transmission Data of Pixels 7 GND Power Ground 8 IN1- Transmission Data of Pixels 1 9 IN1+ Transmission Data of Pixels 1 10 GND Power Ground 11 IN2- Transmission Data of Pixels 2 12 IN2+ Transmission Data of Pixels 2 13 GND Power Ground 14 CLK- Sampling Clock 15 CLK+ Sampling Clock 16 GND Power Ground 17 VLED POWER SUPPLY for Backlight : 5V 18 VLED POWER SUPPLY for Backlight : 5V 19 GND Power Ground 20 LEDADJ Date : 2011/9/5 Function LED PWM SIGNAL 11 8. INPUT SIGNAL : 8-1 LVDS Signal Date : 2011/9/5 12 Date : 2011/9/5 13 9. DISPLAYED COLOR AND INPUT DATA Basic Color Color & Gray Scale R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Blue(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(1) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red(2) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Red(31) 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Red(62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green(1) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Green(2) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Green(31) 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Green(62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 Green(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue(1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue(2) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 : : : : : : : : : : : : : : : : : : : Blue(31) 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 : : : : : : : : : : : : : : : : : : : Blue(62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 DATA SIGNAL Red Green Blue Date : 2011/9/5 14 10. RELIABILITY TEST CONDITIONS 10.1. Test Conditions Tests should be conducted under the following conditions : Ambient temperature : 25  5C Humidity : 60  25% RH. 10.2. Sampling Plan Sampling method shall be in accordance with MIL-STD-105E , level II, normal single sampling plan . 10.3. Acceptable Quality Level A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 10.4. Appearance An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under florescent light. The inspection area of LCD panel shall be within the range of following limits. Date : 2011/9/5 15 10.5. Incoming Inspection Standard Defect Type Limit φ<0.15mm Spot Visual Defect Fiber Internal Polarizer Bubble Mura Bright Dot 0.15mm≦φ≦0.5mm 0.5mm<φ 0.1mm