Preview only show first 10 pages with watermark. For full document please download

Am User Manual

   EMBED


Share

Transcript

AM SERIES CONTENTS ELECTRONIC WEIGHING SCALE 1. INSTALLATION OPERATION MANUAL 2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE 4. INITIAL SETUP ATTEMPT TO OPERATE THE SCALE 5. INSTRUCTION FOR USE 6. TROUBLE SHOOTING 7. DAILY CARE AND MAINTENANCE DECEMBER 1999 Specifications subject to change without prior notice 1. INSTALLATION b. Before first time use, plug the main adaptor into the wall outlet and charge 1.1 Check and make sure that the following the scale for at least 8 hours. accessories are included: This operation manual Scale x 1 c. Retain the packing materials for future transportation purposes. Platter x 1 Power adaptor x 1 Caution: Dust cover x 1 This unit is legal for trade only when it is sealed (and/or stamped) and bearing a serial Contact your dealer if any item missed. number. Do not attempt to break the seal (or stamp) affixed to this scale or remove the 1.2 Insert the platter into the scale carefully. No excessive force is required. 1.3 Power on the scale serial number. Contact your dealer for more information and after sales service. For most accurate weighing result, do not use a. Before plugging the power adaptor into this scale in where or when the environment electricity outlet, check and make sure condition falls beyond as those listed on that the input voltage of power adaptor SPECIFICATIONS. matches with the output voltage of the outlet. If not, do not plug in the adaptor, Do not attempt to open this unit or conduct contact your dealer immediately. any trouble shootings other than those listed on TROUBLE SHOOTING. 2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION Model No. AM-3000 AM-6000 AM-15K AM-30K Capacity 3000g 6000g 15kg 30kg Division 1g 2g 0.005kg 0.01kg Tare Range 999g 1998g 4.995kg 9.990kg Power-on Zero ¡ Ó 300g ¡ Ó 600g ¡ Ó 1.5kg ¡ Ó 3.0kg Range Zero Range ¡ Ó 60g ¡ Ó 120g ¡ Ó 0.3kg ¡ Ó 0.6kg Min. Load 20g 40g 0.1kg 0.2kg o o o o Operation 0 ~40 C (32 ~104 F), Environment Non-condensed. R.H.¡ Ø 85% Power source By Built-in rechargeable battery or power adaptor 1. ON/ZERO KEY Specifications subject to change without notice. Press this key to turn scale on or reset display value to zero. NOTE To comply with the law of certain countries and certain approval requirements, the avoirdupois weight units may be disabled. 2. TARE KEY Press this key to tare off the weight of a container. Contact your dealer for more information. 3. MODE KEY Press this key to shift among different weight units and/or turn backlight on/off. 4. OFF KEY Press this key to turn scale off. 4. INITIAL SETUP 5. IN-CHARGE INDICATOR Red color: Recharging battery 4.1 Placing the Scale Green color: Charging completed In order to obtain an accurate weighing result, the scale must be placed on a strong 6. ZERO INDICATOR and level surface. An arrow will appear and point at this sign to indicate a zero weight status. If required, adjust the adjustable feet underneath scale to obtain a level position. 7. TARE INDICATOR Refer to the bubble indicator for leveling An arrow will appear and point at this sign to indicate the tare function is condition. in operation and weight displayed is net 4.2 Internal Setting weight. 4.2.1 Select weight unit 8. LO-BAT INDICATOR The scale is equipped with metric and When this indicator appears, recharge the avoirdupois weight units. Default setting scale immediately. Failure to do so may = metric weight unit only. Follow the below cause steps to enable/disable the avoirdupois unrecoverable damage to rechargeable battery inside scale. the units. a. Turn scale off b. Press and hold TARE, then press ON/ZERO c. Scale displays F.1 d. Press TARE twice Follow the below steps to enable/disable e. Scale displays F.3 Auto Power Off Function f. Press and hold MODE until the kg or lb sign appears. a. Turn scale off g. Press MODE to shift between kg and lb sign. - - c. Scale displays F.1 To enable the avoirdupois units, d. Press TARE three times press ON/ZERO when the lb sign e. Scale displays F.4 appears. f. Press MODE to shift between 0._OFF and To disable the avoirdupois units, press ON/ZERO when the kg sign appears. 4._OFF. g. To enable Auto Power Off Function, press ON/ZERO when 4._OFF appears. h. After ON/ZERO is pressed, the scale will return to operation status. h. To disable Auto Power Off Function, press ON/ZERO when 0._OFF appears. NOTE i. After ON/ZERO is pressed, the scale will To comply with the law of certain countries and b. Press and hold TARE, then press ON/ZERO certain approval requirements, the avoirdupois weight units may be disabled. Contact your dealer for more information. 4.2.2 Select Auto Power Off Setting The scale is equipped with Auto Power Off Function. The scale will be turned off automatically if it is not used for 4 minutes. return to operation status. 5. INSTRUCTION FOR USE 5.3 Select Weight Unit Press MODE to shift among kg à decimal à lb/oz. 5.1 Before Weighing Make sure that: à kg weight units. Refer to 4.2.1 for internal setting procedures. a. The platter is inserted firmly into the scale b. The scale is placed on a level and strong The weight unit used before power off would be employed when the scale is turned on again. surface. c. The scale is turned on. 5.4 Turn Backlight (Optional) On/Off d. The ZERO INDICATOR is on. If not, press Press MODE to shift among various weight units ZERO/ON to set display to zero. with backlight or without backlight. 5.2 Weighing Even though the backlight function is employed, a. Always place an object onto the platter backlight will be automatically turned off when gently. Excessive force applied to platter a zero weight is detected and remains stable may cause damages to sensor inside scale. for 2 seconds b. The weight of the object would be displayed automatically. c. It is a good practice to remove all loads Backlight will be automatically turned on again when a weight is detected. from platter after weighing. It would prolong the lifetime of scale. 5.5 Set Displayed Value to Zero when Unloaded Pressing the ON/ZERO can eliminate a positive or negative value. After the ON/ZERO is pressed, the ZERO INDICATOR appears. Refer to SPECIFICATIONS for maximum zero range. 5.6 Tare off the Weight of a Container 5.7 Clear the TARE Function When a container is used, follow the below steps Remove all loads from platter then press TARE. to tare off the weight of the container and After TARE is pressed, the TARE INDICATOR would get the net weight. disappear. a. Remove all loads away from platter b. Make sure that the ZERO INDICATOR is on. 5.8 Recharge the Scale c. Place the container on the platter. The d. Press TARE. rechargeable scale INDICATOR is equipped battery. appears, with When a built-in the recharge the LO-BAT scale After TARE is pressed, the TARE INDICATOR would immediately. Failure to do so may cause appear. unrecoverable damage to the rechargeable battery. Refer to 5.2 for weighing procedures. Weight displayed under is the net weight of the subject The scale can remain in operation when being matter. Refer to SPECIFICATIONS for maximum recharged. tare range. Charging is completed when the color of the IN-CHARGE INDICATOR turns green. 6. TROUBLE SHOOTING Syndrome Scale cannot be turned on Check: Is the scale charged? Action: Recharge the scale for at least 8 Syndrome Rated capacity cannot be reached Check Is the TARE INDICATOR on? Action: Turn the scale off. Remove all loads from platter and turn on again. Check hours before first time use or plug in the power adaptor before power Is there anything obstructing the platter? Action Remove all obstacles. Syndrome Blank display with only "kg" or "lb" Check Is the load applied to platter excess on the scale. Check Is the power adaptor inserted properly into both the electricity outlet and the DC inlet of scale. Action: Secure both ends of the power adaptor the rated capacity of scale? Action and try again. Syndrome Scale turned off automatically Check Is Auto Power Off Function employed? Action Refer to 4.2.2 to disable Auto Power Off Function. Check Is the LO-BAT INDICATOR on? Action Apply the power adaptor. Remove all loads from platter and try again. Syndrome Check Scale displays ----Is the platter inserted to the scale correctly? Action Insert the platter to scale correctly. Check Is the stainless steel platter cover placed on the platter? Action Place the stainless steel platter cover onto the platter. Syndrome Weighing result is not accurate Check Is the scale placed in a level condition? Action 7.1 Adjust the adjustable feet to a level condition. Check Action: 7. DAILY CARE AND MAINTENANCE Clean the scale with a soft and damp cloth. If necessary, apply a mild detergent. 7.2 Do not use any harsh, abrasive material, Is the scale affected by airflow, acetone, volatile solvent, thinner or vibration or RFI? alcohol for cleaning. Place the scale away from all 7.3 Verify the accuracy of scale disturbances. periodically. Re-calibrate the scale if Check Is the scale calibrated correctly? necessary. Action Contact your dealer. Note: In some countries, calibration is Check Is the correct weight unit employed? restricted Action Refer to 4.2.1 and 5.3 for weight authorized/qualified unit setting and usage. Contact to your be done by agent dealer an only. for more information. 7.4 It is a good practice to apply the dust cover when operating the scale. 7.5 The scale must be placed horizontally during transportation or long time storage. 7.6 Remove platter from scale before transportation or long time storage. 7.7 Store scale in a dry and clean place.