Series AM15E-IZ 15 Watt | DC-DC Converter FEATURES:
RoHS compliant 2:1 input range Low ripple and noise Remote On/Off control
Power modules for PCB mounting Regulated output Operating temperature range: -40 to +85ºC Synchronous rectifier
Models Single output Input Voltage (V)
Output Voltage (V)
AM15E-1203SIZ AM15E-1205SIZ AM15E-1212SIZ AM15E-1215SIZ AM15E-2403SIZ AM15E-2405SIZ AM15E-2412SIZ AM15E-2415SIZ AM15E-4803SIZ AM15E-4805SIZ AM15E-4812SIZ AM15E-4815SIZ
9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75
3.3 5 12 15 3.3 5 12 15 3.3 5 12 15
AM15E-1203SH30IZ AM15E-1205SH30IZ AM15E-1212SH30IZ AM15E-1215SH30IZ AM15E-2403SH30IZ AM15E-2405SH30IZ AM15E-2412SH30IZ AM15E-2415SH30IZ AM15E-4803SH30IZ AM15E-4805SH30IZ AM15E-4812SH30IZ AM15E-4815SH30IZ
9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75
3.3 5 12 15 3.3 5 12 15 3.3 5 12 15
Input Voltage (V)
Output Voltage (V)
9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75
±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15
9-18 9-18
±5 ±12
Model
Output Current max (A)
Max. Capacitive load (µF)
Ripple & Noise typ
Isolation (VDC)
Efficiency (%)
4 3 1.25 1 4 3 1.25 1 4 3 1.25 1
8100 4700 680 470 8100 4700 680 470 8100 4700 680 470
80mV p-p 80mV p-p 120mVp-p 150mVp-p 80mV p-p 80mV p-p 120mVp-p 150mVp-p 80mV p-p 80mV p-p 120mVp-p 150mVp-p
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
79 83 85 85 81 83 88 87 81 83 88 87
4 3 1.25 1 4 3 1.25 1 4 3 1.25 1
8100 4700 680 470 8100 4700 680 470 8100 4700 680 470
80mV p-p 80mV p-p 120mVp-p 150mVp-p 80mV p-p 80mV p-p 120mVp-p 150mVp-p 80mV p-p 80mV p-p 120mVp-p 150mVp-p
3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
74 78 82 83 75 77 84 83 75 76 85 85
Max. Capacitive load (µF)
Ripple & Noise typ
Isolation (VDC)
Efficiency (%)
±1.5 ±0.62 ±0.5 ±1.5 ±0.62 ±0.5 ±1.5 ±0.62 ±0.5
±2300 ±340 ±230 ±2300 ±340 ±230 ±2300 ±340 ±230
50mVp-p 120mVp-p 150mVp-p 50mVp-p 120mVp-p 150mVp-p 50mVp-p 120mVp-p 150mVp-p
1500 1500 1500 1500 1500 1500 1500 1500 1500
85 85 85 83 88 87 83 88 87
±1.5 ±0.62
±2300 ±340
50mVp-p 120mVp-p
3000 3000
78 82
Models Dual output Model AM15E-1205DIZ AM15E-1212DIZ AM15E-1215DIZ AM15E-2405DIZ AM15E-2412DIZ AM15E-2415DIZ AM15E-4805DIZ AM15E-4812DIZ AM15E-4815DIZ AM15E-1205DH30IZ AM15E-1212DH30IZ www.aimtec.com F 051e R12.D
Output Current max (A)
Tel: +1 514 620 2722 1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM15E-IZ 15 Watt | DC-DC Converter Models Dual output (continued) Model AM15E-1215DH30IZ AM15E-2405DH30IZ AM15E-2412DH30IZ AM15E-2415DH30IZ AM15E-4805DH30IZ AM15E-4812DH30IZ AM15E-4815DH30IZ
Input Voltage (V)
Output Voltage (V)
9-18 18-36 18-36 18-36 36-75 36-75 36-75
±15 ±5 ±12 ±15 ±5 ±12 ±15
Output Current max (A)
Max. Capacitive load (µF)
Ripple & Noise typ
Isolation (VDC)
Efficiency (%)
±230 ±2300 ±340 ±230 ±2300 ±340 ±230
150mVp-p 50mVp-p 120mVp-p 150mVp-p 50mVp-p 120mVp-p 150mVp-p
3000 3000 3000 3000 3000 3000 3000
81 80 82 84 76 83 85
±0.5 ±1.5 ±0.62 ±0.5 ±1.5 ±0.62 ±0.5
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications Parameters Voltage range
Nominal
Typical
12 24 48
9-18 18-36 37-75
On Off 12 Vin 24 Vin 48 Vin
Absolute Maximum Rating Permissible absolute maximum duration Recommended Input Fuse (slow blow)
Units VDC
(Pi) Network 3.5 to 12VDC or open circuit 0 to 1.2VDC or short circuit between pin 2 and 4; typical idle current 3mA 25 50 VDC 100 2 h 4A/250V 2A/250V 1A/250V
Filter Remote On/Off Control
Maximum
12 Vin 24 Vin 48 Vin
Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance
Conditions
Typical
3 sec
Maximum
1500 & 3000 > 1000 1000
Units VDC MOhm pF
Output Specifications Parameters Voltage accuracy Short Circuit protection Short Circuit restart Over voltage protection Over load protection Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Transient response recovery time
www.aimtec.com F 051e R12.D
Conditions
Typical
Maximum
±2
HL-LL 0-100% 0-100% 25% load step change
Continuous Auto recovery Zener diode clamp protection Over 110% full load with auto-recovery ±0.5 ±0.5 ±2 ±0.05 300
Tel: +1 514 620 2722 2 of 5
Units %
% % % %/oC uS
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM15E-IZ 15 Watt | DC-DC Converter General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF
Conditions
Typical
100% load See derating curves
200
Maximum
Units
95
KHz oC oC oC
-40 to+85 -55 to +115 Free air convection
95 Nickel coated copper 33 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.50 mm > 800 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
% g
Safety Specifications Parameters Agency approvals Standards
CE EN 55022, EN 55024 class B
Pin Out Specifications Pin
Single
Dual
1 2 3 4 5 6
On/Off Control -V Input +V Input -V Output No pin +V Output
On/Off Control -V Input +V Input -V Output Common +V Output
Derating 1500VDC Isolation
3000VDC Isolation
Free Air Convection 75 ºC
Output Power (%)
100 80
Safe Operating Area 60 40 20 0 - 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com F 051e R12.D
Tel: +1 514 620 2722 3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM15E-IZ 15 Watt | DC-DC Converter
2.54 (0.10) 10.16 (0.40)
6.00 (0.24)
10.50 (0.41)
2.54 (0.10)
10.16 (0.40)
7.62 5.08 (0.30) (0.20)
25.40 (1.00)
10.16 (0.40)
Dimensions
Block diagram
www.aimtec.com F 051e R12.D
Tel: +1 514 620 2722 4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM15E-IZ 15 Watt | DC-DC Converter Control ON/OFF pin connection example: Single Output
Dual Output
The converter output can be disabled by moving SW to position “a”. When SW is in position “b”, the converter operates normally. The SW can be replaced by a NPN transistor with connection as follows: Note: The control voltage is referenced to negative input (-Vi )
Digital Control Circuit:
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com F 051e R12.D
Tel: +1 514 620 2722 5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832) North America only