Transcript
Series AM3T-RZ 3 Watt | DC-DC Converter FEATURES:
RoHS compliant Wide 2:1 input range High efficiency up to 82% Auto recovery short circuit protection
Operating temperature -40oC to + 85oC Input / Output Isolation 1500VDC Pin compatible with multiple manufacturers Low profile metal package
Models Single output Model AM3T-1203S-RZ AM3T-1205S-RZ AM3T-1207S-RZ AM3T-1209S-RZ AM3T-1212S-RZ AM3T-1215S-RZ AM3T-1218S-RZ AM3T-1224S-RZ AM3T-2403S-RZ AM3T-2405S-RZ AM3T-2407S-RZ AM3T-2409S-RZ AM3T-2412S-RZ AM3T-2415S-RZ AM3T-2418S-RZ AM3T-2424S-RZ AM3T-4803S-RZ AM3T-4805S-RZ AM3T-4807S-RZ AM3T-4809S-RZ AM3T-4812S-RZ AM3T-4815S-RZ AM3T-4818S-RZ AM3T-4824S-RZ
Input Voltage (V)
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max (μF)
Efficiency (%)
3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24
900 600 417 333 250 200 167 125 900 600 417 333 250 200 167 125 900 600 417 333 250 200 167 125
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
470 470 68 68 47 47 22 22 470 470 68 68 47 47 22 22 470 470 68 68 47 47 22 22
72 76 78 78 80 80 80 80 72 76 79 78 80 82 79 82 72 76 77 78 80 80 80 80
Input Voltage (V)
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max (μF)
Efficiency (%)
9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 18-36 18-36 18-36
±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24
±450 ±300 ±208 ±167 ±125 ±100 ±84 ±63 ±450 ±300 ±208 ±167 ±125 ±100 ±84 ±63
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
±220 ±220 ±33 ±33 ±22 ±22 ±10 ±10 ±220 ±220 ±33 ±33 ±22 ±22 ±10 ±10
72 76 78 80 80 80 78 80 72 78 81 80 82 82 82 82
9-18 9-18 9-18 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 36-72 36-72 36-72
Models Dual output Model AM3T-1203D-RZ AM3T-1205D-RZ AM3T-1207D-RZ AM3T-1209D-RZ AM3T-1212D-RZ AM3T-1215D-RZ AM3T-1218D-RZ AM3T-1224D-RZ AM3T-2403D-RZ AM3T-2405D-RZ AM3T-2407D-RZ AM3T-2409D-RZ AM3T-2412D-RZ AM3T-2415D-RZ AM3T-2418D-RZ AM3T-2424D-RZ www.aimtec.com F 051e R12.C
Tel: +1 514 620 2722 1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3T-RZ 3 Watt | DC-DC Converter Models Dual output (continued) Model
Input Voltage (V)
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max (μF)
Efficiency (%)
36-72 36-72 36-72 36-72 36-72 36-72 36-72 36-72
±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24
±450 ±300 ±208 ±167 ±125 ±100 ±84 ±63
1500 1500 1500 1500 1500 1500 1500 1500
±220 ±220 ±33 ±33 ±22 ±22 ±10 ±10
72 76 78 78 80 80 78 80
AM3T-4803D-RZ AM3T-4805D-RZ AM3T-4807D-RZ AM3T-4809D-RZ AM3T-4812D-RZ AM3T-4815D-RZ AM3T-4818D-RZ AM3T-4824D-RZ
Input Specifications Parameters Voltage range
Nominal
Typical
12 24 48
9-18 18-36 36-72
Maximum
Units VDC
(Pi) Network
Filter Turn on Transient process time Start up time 12 Vin 24 Vin 48 Vin
Absolute Maximum Rating Peak Input Voltage time
500 -0.7-24 -0.7-40 -0.7-80 100
350
Typical
Rated
Units
1500
VDC VDC MOhm pF
Maximum
Units
ms ms VDC ms
Isolation Specifications Parameters
Conditions
Tested I/O voltage Case/ Input & Output Resistance Capacitance
3 sec 1000 > 1000 470
Output Specifications Parameters
Conditions
Voltage accuracy Voltage balance Dual output Short Circuit protection Short Circuit restart Current limiting Line voltage regulation Load voltage regulation Load voltage regulation 3.3V/±3.3V Models Temperature coefficient Ripple & Noise Rising time
Typical ±1 ±1
% % Continuous Auto recovery 120% of Iout max
LL-HL Load: 10…100% Load: 10…100%
±0.5 ±0.5 ±1.5
% % %
At 20MHz Bandwidth
±0.02 60 10
%/oC mV p-p ms
General Specifications Parameters
Conditions
Typical
Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity
100% load Full Load without Derating
266
www.aimtec.com F 051e R12.C
Maximum
Units
100
KHz o C o C o C
95
% RH
-40 to +85 -40 to +125 Free air convection
Tel: +1 514 620 2722 2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3T-RZ 3 Watt | DC-DC Converter General Specifications (continued) Parameters
Conditions
Typical
Maximum
Units
Case material Nickel-coated copper Weight 17 g Dimensions(L x W x H) Tolerance ±0.5 mm or ±0.02 inches 1.28 x 0.84 x 0.41 inches 32.25 x 21.35 x 10.5 mm MTBF >1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Safety Specifications Parameters CE EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A NOTE: also designed to meet IEC 60950-1:2001
Safety standards
Pin Out Specifications Dual -V Input -V Input Common -V Output +V Output Common +V Input +V Input
1 2 3 0.25 (0.01)
Single -V Input -V Input No pin N.C. +V Output -V Output +V Input +V Input
0.50 (0.02)
Printed Face
F 051e R12.C
24 23 22
16 15 14 13
Built-in Stand-offs to ease PCB cleaning
All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002) Pin Pitch Tolerance: ± 0.35 (±0.014) Case Tolerence: ± 0.5 (±0.02) 3.05 (0.12)
Test Circuits Conducted Emissions:
www.aimtec.com
9 10 1112
Bottom View
2.54 (0.10)
10.50 (0.41)
2 3 9 11 14 16 22 23
32.25 (1.28)
1500VDC 21.35 (0.84)
Pin
27.96 (1.10)
Dimensions
15.24 (0.60)
Agency approvals
Tel: +1 514 620 2722 3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3T-RZ 3 Watt | DC-DC Converter
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com F 051e R12.C
Tel: +1 514 620 2722 4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only