Amana Dgph13m Product Data Specifications

   EMBED


Share

Transcript

GPH13M ® Packaged Heat Pump 13 SEER / R-410A ® Cooling Capacity: 24,000 - 56,000 BTU/h Heating Capacity: 23,000 - 55,500 BTU/h 2 to 5 Tons Standard Features • Energy-efficient compressor with internal relief valve • PSC blower motor; EEM blower motor on 4- & 5-ton units • Convertible airflow: horizontal or downflow • Copper tube/aluminum fin coils • Totally enclosed, permanently lubricated condenser fan motor • Fully charged R-410A system • Electric heat kit available as a field-installed option • AHRI Certified; ETL Listed Cabinet Features • Heavy-gauge galvanized-steel cabinet • Attractive Architectural Gray powder-paint finish • Fully insulated air-handling compartment with convenient access panels • Louvered condenser coil protection • One footprint; two heights Contents Nomenclature............................................................................2 Product Specifications...............................................................3 Expanded Cooling Data.............................................................4 Expanded Heating Data...........................................................16 Airflow Data.............................................................................19 Heat Kit Electrical Data............................................................20 Dimensions..............................................................................21 Wiring Diagrams .....................................................................22 Accessories...............................................................................24 * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 10Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-DGPH13M www.amana-hac.com Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. 2/12 Supersedes 11/11 Product Specifications Nomenclature G 1 P 2 H 3 13 4,5 36 6,7 M 8 4 9 A 11 * 12 Brand G Goodman or Distinctions™ Engineering Minor Revision Product Category P Packaged Unit Engineering Major Revision Type H Heat Pump C Air Conditioner Voltage Designator 1 208-230/1/60 3 208-230/3/60 4 460/3/60 Efficiency 13 13 SEER 14 14 SEER Refrigerant 2 R-22 4 R-410A 15 15 SEER 16 16 SEER Nominal Capacity 24 2 Tons 42 3½ Tons 30 2½ tons 48 4 Tons 36 3 Tons 60 5 Tons 2 1 10 Configuration H Horizontal M Multi-position www.amana-hac.com SS-DGPH13M Product Specifications Specifications GPH13 24M41A* GPH13 30M41A* GPH13 36M41A* GPH13 42M41A* GPH13 48M41A* GPH13 60M41A* Cooling Capacity Total BTU/h 24,000 29,000 34,600 40,000 46,500 56,000 Sensible BTU/h 18,400 22,300 25,400 29,200 36,800 40,800 SEER / EER 13/11 13/10.8 13/10.9 13/11 13/11 13/10.9 76.7 75.3 81.3 80.1 79.1 80.2 4385118 4385120 4385122 4385125 4385127 4385130 BUT/h (47°F) 23,000 28,800 34,200 40,000 45,500 55,500 C.O.P (47°F) 3.5 3.5 3.5 3.5 3.7 3.6 Decibels AHRI NUMBERS Heating Capacity BUT/h (17°F) 12,600 17,000 19,000 21,000 26,000 31,200 C.O.P (17°F) 2.14 2.18 2.1 2.18 2.3 2.24 HSPF 7.7 7.7 7.7 7.7 8.0 8.0 PSC PSC PSC PSC EEM EEM 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9 825 1,050 1,050 1,300 1,720 1,800 1.5 / 2.13 1.5 / 3.2 3.06 / 4.1 3.06 / 4.1 5.8 / -- 7.6 / -- Evaporator Motor Type Wheel (DxW) Nominal Cooling CFM FLA/LRA No. of Speeds Horsepower - RPM 3 3 3 3 5 5 ¼ - 952 ⅓ - 869 ⅓ - 910 ⅓ - 910 ¾ - 1,050 1 - 1,050 Evaporator Coil Face Area (ft²) Rows Deep/ Fin per Inch Drain Size (NPT) Refrigerant Charge (oz.) 4.52 4.52 4.52 4.52 6.17 6.17 4 / 16 4 / 16 4 / 14 4 / 14 4 / 14 4 / 14 ¾” ¾” ¾” ¾” ¾” ¾” 110 115 135 180 190 220 Condenser Fan / Coil Horsepower - RPM ¼ - 830 ¼ - 830 ¼ - 830 ¼ - 1,075 ¼ - 1,075 ¼ - 1,075 FLA/LRA 1.5 / 3.0 1.5 / 3.0 1.5 / 3.0 1.4 / 2.9 1.4 / 2.9 1.4 / 2.9 Fan Diameter / # Fan Blades 22/3 22/3 22/4 22/3 22/3 22/3 Face Area (ft²) 17.02 17.02 16.83 16.83 19.24 21.04 Rows Deep/ Fin per Inch 1 / 24 1 / 24 1 / 22 2 / 16 2 / 16 2 / 16 Compressor Quantity 1 1 1 1 1 1 Type Scroll Scroll Scroll Scroll Scroll Scroll Stage Single Single Single Single Single Single 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 12.8 / 58.3 16 / 77 16.7 / 79 17.9 / 112 21.8 / 117 26.4 / 134 15.8 19 21.26 22.36 29 35.4 Electrical Data Voltage/ Phase/ Frequency Compressor RLA/ LRA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection² Shipping Weight (lbs) 19.0 23.0 25.4 26.8 34.5 42.0 30 amps 35 amps 40 amps 40 amps 50 amps 60 amps 405 410 435 440 520 533 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-DGPH13M www.amana-hac.com 3 4 www.amana-hac.com 23.9 0.88 21 1.71 7.4 233 114 23.2 0.84 22 1.70 7.4 231 113 21.4 0.81 22 1.66 7.2 224 109 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 723 825 927 59 23.5 0.77 18 1.69 7.4 231 113 22.8 0.74 19 1.68 7.3 229 111 21.1 0.71 19 1.64 7.1 222 108 Airflow MBh S/T ∆T kW 927 Amps Hi Pr Lo Pr MBh S/T ∆T kW 825 Amps Hi Pr Lo Pr MBh S/T ∆T 723 kW Amps Hi Pr Lo Pr 24.6 0.78 19 1.74 7.6 251 121 23.9 0.75 20 1.73 7.5 249 120 22.1 0.72 20 1.69 7.3 241 116 63 24.4 0.64 16 1.73 7.5 249 120 23.7 0.61 16 1.72 7.4 246 119 21.8 0.59 16 1.68 7.3 239 115 26.7 0.59 16 1.79 7.7 265 132 25.9 0.57 16 1.78 7.7 263 131 23.9 0.55 17 1.74 7.5 255 127 67 26.7 0.45 12 1.78 7.7 263 131 25.9 0.43 12 1.77 7.6 260 129 23.9 0.41 12 1.73 7.5 252 126 28.6 0.38 11 1.85 8.0 277 141 27.8 0.36 11 1.83 7.9 274 139 25.6 0.35 11 1.79 7.7 266 135 71 23.4 0.91 21 1.83 7.9 262 120 22.7 0.87 22 1.82 7.8 259 119 20.9 0.84 22 1.78 7.7 252 115 59 23.0 0.80 18 1.82 7.8 259 119 22.3 0.76 19 1.80 7.8 257 118 20.6 0.73 19 1.76 7.6 249 114 24.1 0.81 19 1.87 8.0 282 128 23.4 0.77 20 1.85 8.0 279 127 21.6 0.75 20 1.81 7.8 271 123 63 23.8 0.67 16 1.85 8.0 279 127 23.1 0.64 16 1.84 7.9 276 125 21.3 0.61 17 1.80 7.7 268 122 26.0 0.61 16 1.93 8.3 298 140 25.3 0.59 17 1.91 8.2 295 138 23.3 0.57 17 1.87 8.0 286 134 67 26.1 0.46 12 1.91 8.2 295 138 25.3 0.44 12 1.90 8.1 292 137 23.4 0.43 13 1.85 8.0 283 133 75ºF 27.9 0.40 11 1.99 8.5 310 149 27.1 0.38 11 1.97 8.4 307 147 25.0 0.36 12 1.92 8.3 298 143 71 22.8 0.93 21 1.94 8.4 298 125 22.1 0.89 22 1.93 8.4 295 124 20.4 0.86 22 1.88 8.2 286 120 59 22.4 0.82 18 1.93 8.4 295 124 21.8 0.78 19 1.91 8.3 292 122 20.1 0.75 19 1.87 8.1 283 119 23.5 0.83 19 1.98 8.6 321 133 22.8 0.79 20 1.97 8.5 317 132 21.0 0.77 21 1.92 8.4 308 128 25.4 0.63 16 2.04 8.8 338 145 24.7 0.60 17 2.03 8.8 335 144 22.8 0.58 17 1.98 8.6 325 139 27.3 0.41 11 2.11 9.1 353 154 26.5 0.39 11 2.09 9.1 350 153 24.4 0.37 12 2.04 8.8 339 148 22.2 0.96 21 2.04 8.9 339 131 21.6 0.92 22 2.02 8.8 336 130 19.9 0.88 22 1.97 8.6 326 126 22.9 0.86 20 2.08 9.1 365 140 22.2 0.82 20 2.06 9.0 361 138 20.5 0.79 21 2.01 8.8 351 134 24.8 0.65 16 2.14 9.4 386 152 24.1 0.62 17 2.13 9.3 382 151 22.2 0.60 17 2.08 9.1 370 146 26.6 0.42 11 2.21 9.7 402 162 25.8 0.40 11 2.20 9.6 398 161 23.8 0.39 12 2.14 9.4 386 156 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 23.2 25.5 21.9 22.7 24.8 0.68 0.47 0.85 0.71 0.49 16 12 18 16 12 1.97 2.03 2.02 2.06 2.13 8.5 8.8 8.8 9.0 9.3 317 335 336 361 382 132 144 130 138 151 22.6 24.7 21.2 22.0 24.1 0.65 0.45 0.81 0.67 0.47 16 12 19 17 13 1.95 2.01 2.00 2.05 2.11 8.5 8.7 8.8 9.0 9.2 314 332 333 358 378 130 142 129 137 149 20.8 22.8 19.6 20.3 22.3 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 1.90 1.96 1.96 2.00 2.06 8.3 8.5 8.6 8.8 9.0 305 322 323 347 367 126 138 125 133 145 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 21.8 0.89 19 2.16 9.6 411 146 21.1 0.85 20 2.15 9.5 407 145 19.5 0.82 20 2.10 9.3 394 140 63 21.5 0.73 16 2.15 9.5 407 145 20.9 0.70 16 2.13 9.4 403 143 19.3 0.67 17 2.08 9.2 390 139 23.6 0.68 16 2.23 9.9 434 160 22.9 0.64 16 2.21 9.8 429 158 21.1 0.62 17 2.16 9.6 417 153 67 23.6 0.51 12 2.21 9.8 429 158 22.9 0.48 12 2.20 9.7 425 157 21.1 0.47 13 2.14 9.5 412 152 25.3 0.43 11 2.30 10.2 452 170 24.5 0.41 11 2.29 10.1 448 168 22.7 0.40 12 2.23 9.9 434 163 71 19.6 1.00 19 2.19 9.9 422 142 19.0 0.96 20 2.17 9.8 418 141 17.5 0.93 21 2.12 9.6 405 137 59 19.3 0.89 17 2.17 9.8 417 141 18.7 0.84 18 2.15 9.7 413 139 17.3 0.81 18 2.10 9.5 401 135 20.2 0.90 18 2.24 10.1 454 151 19.6 0.86 19 2.22 10.0 449 150 18.1 0.83 19 2.16 9.8 436 145 63 20.0 0.74 15 2.22 10.0 449 150 19.4 0.71 15 2.20 9.9 445 148 17.9 0.68 15 2.15 9.7 431 144 21.8 0.68 15 2.31 10.4 479 165 21.2 0.65 15 2.29 10.3 474 164 19.6 0.63 16 2.23 10.0 460 159 67 21.9 0.51 11 2.29 10.3 474 164 21.2 0.49 12 2.27 10.2 470 162 19.6 0.47 12 2.22 10.0 456 157 115ºF 23.4 0.44 10 2.38 10.7 500 176 22.7 0.42 11 2.36 10.6 495 174 21.0 0.40 11 2.31 10.4 480 169 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 21.1 1.00 21 2.12 9.4 382 138 20.5 0.95 22 2.10 9.3 378 136 18.9 0.92 22 2.05 9.1 367 132 59 20.8 0.88 18 2.10 9.3 378 136 20.2 0.84 19 2.09 9.2 374 135 18.6 0.81 19 2.04 9.0 363 131 105ºF Product Specifications Expanded Cooling Data — GPH1324M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 24.8 1.00 25 1.73 7.5 238 116 24.0 0.96 26 1.72 7.5 236 115 22.2 0.93 26 1.68 7.3 229 111 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 723 825 927 59 24.3 0.96 23 1.72 7.5 236 115 23.6 0.92 24 1.71 7.4 233 114 21.8 0.88 25 1.67 7.3 226 110 Airflow MBh S/T ∆T kW 927 Amps Hi Pr Lo Pr MBh S/T ∆T kW 825 Amps Hi Pr Lo Pr MBh S/T ∆T 723 kW Amps Hi Pr Lo Pr 25.2 0.97 24 1.77 7.7 256 123 24.5 0.93 25 1.76 7.6 254 122 22.6 0.89 26 1.72 7.4 246 119 63 24.9 0.90 22 1.76 7.6 254 122 24.1 0.86 23 1.74 7.6 251 121 22.3 0.83 24 1.70 7.4 244 117 26.4 0.88 23 1.82 7.9 271 135 25.7 0.84 24 1.81 7.8 268 133 23.7 0.81 24 1.77 7.6 260 129 67 26.6 0.73 19 1.81 7.8 268 133 25.8 0.70 20 1.79 7.7 265 132 23.8 0.67 20 1.75 7.6 257 128 28.2 0.71 20 1.88 8.1 282 144 27.4 0.68 21 1.86 8.0 279 142 25.3 0.65 21 1.82 7.9 271 138 71 28.4 0.55 15 1.86 8.0 279 142 27.6 0.52 16 1.85 8.0 277 141 25.5 0.50 16 1.81 7.8 268 136 24.2 1.00 24 1.86 8.0 267 123 23.5 1.00 26 1.85 7.9 265 121 21.7 0.96 26 1.80 7.8 257 118 59 23.8 1.00 24 1.85 7.9 265 121 23.1 0.95 24 1.83 7.9 262 120 21.3 0.92 25 1.79 7.7 254 117 24.7 1.00 24 1.90 8.2 288 130 23.9 0.96 26 1.88 8.1 285 129 22.1 0.93 26 1.84 7.9 276 125 63 24.3 0.93 23 1.88 8.1 285 129 23.6 0.89 23 1.87 8.0 282 128 21.8 0.86 24 1.83 7.9 273 124 25.8 0.91 23 1.96 8.4 304 142 25.1 0.87 24 1.94 8.3 301 141 23.1 0.84 25 1.90 8.1 292 137 67 26.0 0.76 20 1.94 8.3 301 141 25.2 0.73 20 1.93 8.3 298 140 23.3 0.70 21 1.88 8.1 289 135 75ºF 27.6 0.74 20 2.02 8.6 317 152 26.8 0.70 21 2.00 8.6 314 150 24.7 0.68 21 1.95 8.4 304 146 71 27.7 0.57 16 2.00 8.6 314 150 26.9 0.54 16 1.99 8.5 310 149 24.9 0.52 17 1.94 8.3 301 144 23.6 1.00 23 1.97 8.6 304 127 22.9 1.00 26 1.96 8.5 301 126 21.2 0.98 27 1.91 8.3 292 122 59 23.2 1.00 23 1.96 8.5 301 126 22.5 0.97 24 1.94 8.4 298 125 20.8 0.94 25 1.90 8.3 289 121 24.1 1.00 24 2.01 8.7 327 136 23.4 0.99 26 2.00 8.7 324 134 21.6 0.95 26 1.95 8.5 314 130 25.2 0.93 23 2.07 9.0 345 148 24.5 0.89 24 2.06 8.9 342 147 22.6 0.86 25 2.01 8.7 332 142 26.9 0.76 20 2.14 9.3 360 158 26.1 0.72 21 2.12 9.2 357 156 24.1 0.70 21 2.07 9.0 346 151 23.0 1.00 23 2.07 9.1 346 134 22.4 1.00 25 2.05 9.0 343 133 20.6 1.00 26 2.00 8.8 332 129 23.5 1.00 23 2.11 9.2 372 142 22.8 1.00 25 2.10 9.2 369 141 21.0 0.98 26 2.05 9.0 358 137 24.6 0.96 23 2.18 9.5 393 155 23.9 0.92 24 2.16 9.4 389 154 22.0 0.89 25 2.11 9.2 378 149 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.7 25.3 27.1 22.6 23.1 24.7 0.96 0.78 0.58 1.00 1.00 0.80 23 20 16 22 23 20 2.00 2.06 2.12 2.05 2.10 2.16 8.7 8.9 9.2 9.0 9.2 9.4 324 342 357 343 369 389 134 147 156 133 141 154 23.0 24.6 26.3 22.0 22.5 24.0 0.91 0.74 0.56 1.00 0.94 0.77 23 20 16 24 24 21 1.98 2.04 2.11 2.04 2.08 2.15 8.6 8.8 9.1 8.9 9.1 9.4 321 339 353 339 365 386 133 145 155 131 140 152 21.3 22.7 24.3 20.3 20.7 22.2 0.88 0.72 0.54 0.97 0.91 0.74 24 21 17 25 24 21 1.93 1.99 2.06 1.99 2.03 2.09 8.4 8.6 8.9 8.7 8.9 9.1 311 328 342 329 354 374 129 141 150 127 135 148 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 26.2 0.78 20 2.25 9.8 410 166 25.5 0.74 21 2.23 9.7 406 164 23.5 0.72 21 2.18 9.5 394 159 71 26.4 0.60 16 2.23 9.7 406 164 25.7 0.57 16 2.21 9.7 402 162 23.7 0.55 17 2.16 9.4 390 157 22.3 1.00 22 2.20 9.7 419 149 21.7 1.00 24 2.18 9.7 415 148 20.0 1.00 25 2.13 9.4 402 143 63 22.0 1.00 22 2.18 9.7 415 148 21.3 0.98 23 2.16 9.6 411 146 19.7 0.94 24 2.11 9.4 398 142 23.4 1.00 23 2.27 10.0 442 163 22.7 0.95 24 2.25 9.9 438 161 20.9 0.92 24 2.20 9.7 425 156 67 23.5 0.84 19 2.25 9.9 438 161 22.8 0.80 20 2.23 9.9 434 160 21.0 0.77 21 2.18 9.6 421 155 24.9 0.81 20 2.34 10.3 462 174 24.2 0.77 21 2.32 10.3 457 172 22.3 0.75 21 2.27 10.0 443 167 71 25.1 0.62 16 2.32 10.3 457 172 24.4 0.60 16 2.30 10.2 452 170 22.5 0.57 16 2.25 9.9 439 165 20.3 1.00 20 2.22 10.0 430 145 19.7 1.00 22 2.21 9.9 426 144 18.2 1.00 23 2.15 9.7 413 139 59 19.9 1.00 20 2.21 9.9 426 144 19.3 1.00 22 2.19 9.9 422 142 17.9 1.01 23 2.14 9.6 409 138 20.7 1.00 20 2.27 10.2 463 154 20.1 1.00 22 2.25 10.2 458 153 18.5 1.00 24 2.20 9.9 445 148 63 20.4 1.00 20 2.25 10.2 458 153 19.8 0.99 22 2.24 10.1 454 151 18.2 0.95 22 2.18 9.8 440 147 21.6 23.1 1.00 0.82 21 19 2.35 2.42 10.5 10.9 489 510 169 179 21.0 22.4 0.96 0.78 23 19 2.33 2.40 10.4 10.8 484 505 167 178 19.4 20.7 0.93 0.75 23 20 2.27 2.34 10.2 10.5 470 490 162 172 67 71 21.8 23.3 0.84 0.63 18 15 2.33 2.40 10.4 10.8 484 505 167 178 21.1 22.6 0.80 0.60 19 15 2.31 2.38 10.4 10.7 479 500 165 176 19.5 20.8 0.77 0.58 19 15 2.25 2.32 10.1 10.4 465 485 160 171 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 21.9 1.00 22 2.15 9.5 389 140 21.2 1.00 24 2.14 9.5 386 139 19.6 1.00 25 2.08 9.2 374 135 59 21.5 1.00 21 2.14 9.5 386 139 20.9 1.00 23 2.12 9.4 382 138 19.3 1.01 25 2.07 9.2 370 133 105ºF Product Specifications Expanded Cooling Data — GPH1324M41A* (cont.) 5 6 www.amana-hac.com 28.9 0.88 20 2.22 9.6 234 110 28.1 0.84 21 2.20 9.5 232 109 25.9 0.81 21 2.15 9.3 225 106 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 920 1050 1180 59 28.4 0.77 17 2.20 9.5 232 109 27.6 0.74 18 2.18 9.4 229 108 25.5 0.71 18 2.14 9.2 223 105 Airflow MBh S/T ∆T kW 1180 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1050 Amps Hi Pr Lo Pr MBh S/T ∆T 920 kW Amps Hi Pr Lo Pr 29.8 0.78 18 2.26 9.8 252 117 28.9 0.75 19 2.24 9.7 249 116 26.7 0.72 19 2.19 9.5 242 112 63 29.5 0.64 15 2.24 9.7 249 116 28.6 0.61 15 2.23 9.6 247 115 26.4 0.59 16 2.18 9.4 240 111 32.2 0.59 15 2.33 10.0 266 128 31.3 0.57 15 2.31 9.9 263 126 28.9 0.55 16 2.26 9.7 256 123 67 32.3 0.45 11 2.31 9.9 263 126 31.3 0.43 12 2.29 9.9 261 125 28.9 0.41 12 2.24 9.7 253 121 34.6 0.38 10 2.40 10.3 277 136 33.6 0.36 11 2.38 10.3 275 135 31.0 0.35 11 2.33 10.0 267 131 71 28.2 0.91 20 2.38 10.2 263 116 27.4 0.87 21 2.36 10.1 260 115 25.3 0.83 21 2.31 9.9 252 112 59 27.8 0.80 17 2.36 10.1 260 115 26.9 0.76 18 2.34 10.1 257 114 24.9 0.73 18 2.29 9.8 250 110 29.1 0.81 18 2.43 10.4 283 124 28.2 0.77 19 2.41 10.3 280 122 26.0 0.75 19 2.35 10.1 272 119 63 28.8 0.67 15 2.41 10.3 280 122 27.9 0.64 16 2.39 10.3 277 121 25.8 0.61 16 2.33 10.0 269 117 31.5 0.61 15 2.50 10.7 299 135 30.5 0.59 16 2.48 10.6 296 134 28.2 0.57 16 2.42 10.4 287 130 67 31.5 0.46 11 2.48 10.6 296 134 30.6 0.44 12 2.46 10.5 293 132 28.2 0.42 12 2.41 10.3 284 128 75ºF 33.8 0.40 10 2.58 11.0 311 144 32.8 0.38 11 2.56 10.9 308 142 30.3 0.36 11 2.50 10.7 299 138 71 27.6 0.93 20 2.52 10.9 299 121 26.8 0.89 21 2.50 10.9 296 120 24.7 0.86 21 2.44 10.6 287 116 59 27.1 0.82 17 2.50 10.9 296 120 26.3 0.78 18 2.48 10.8 293 118 24.3 0.75 18 2.42 10.5 284 115 28.4 0.83 18 2.57 11.2 322 128 27.5 0.79 19 2.55 11.1 318 127 25.4 0.77 19 2.49 10.8 309 123 30.7 0.63 15 2.65 11.5 340 140 29.8 0.60 16 2.63 11.4 336 139 27.5 0.58 16 2.57 11.1 326 135 33.0 0.41 10 2.74 11.8 354 149 32.0 0.39 11 2.72 11.7 351 148 29.5 0.37 11 2.65 11.5 340 143 26.9 0.96 20 2.65 11.6 340 127 26.1 0.92 21 2.63 11.5 337 126 24.1 0.88 21 2.56 11.2 327 122 27.7 0.86 19 2.70 11.8 366 135 26.9 0.82 19 2.68 11.7 363 134 24.8 0.79 20 2.62 11.4 352 130 30.0 0.65 15 2.79 12.1 387 147 29.1 0.62 16 2.76 12.0 383 146 26.8 0.60 16 2.70 11.8 371 141 32.2 0.42 10 2.88 12.5 403 157 31.2 0.40 11 2.85 12.4 399 155 28.8 0.38 11 2.78 12.1 387 151 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 28.1 30.8 26.4 27.4 30.0 0.68 0.47 0.85 0.71 0.49 15 11 17 15 11 2.55 2.63 2.63 2.68 2.76 11.1 11.4 11.5 11.7 12.0 318 336 337 363 383 127 139 126 134 146 27.3 29.9 25.7 26.6 29.1 0.65 0.45 0.81 0.67 0.47 16 12 18 16 12 2.53 2.61 2.60 2.66 2.74 11.0 11.3 11.4 11.6 12.0 315 333 334 359 379 126 137 124 132 144 25.2 27.6 23.7 24.6 26.9 0.63 0.44 0.78 0.65 0.45 16 12 18 16 12 2.47 2.55 2.54 2.60 2.68 10.7 11.0 11.1 11.4 11.7 306 323 324 348 368 122 133 121 128 140 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 26.3 0.89 18 2.81 12.5 412 141 25.5 0.85 19 2.79 12.4 408 140 23.6 0.82 19 2.72 12.1 396 136 63 26.0 0.73 15 2.79 12.4 408 140 25.3 0.70 15 2.77 12.3 404 139 23.3 0.67 16 2.70 12.0 392 134 28.5 0.68 15 2.90 12.8 435 154 27.6 0.64 16 2.88 12.7 431 153 25.5 0.62 16 2.81 12.4 418 148 67 28.5 0.51 11 2.88 12.7 431 153 27.7 0.48 12 2.85 12.6 426 151 25.6 0.47 12 2.78 12.3 414 147 30.5 0.43 10 2.99 13.2 454 164 29.7 0.41 11 2.97 13.1 449 163 27.4 0.40 11 2.90 12.8 436 158 71 23.7 1.00 18 2.84 12.8 423 137 23.0 0.96 19 2.82 12.7 419 136 21.2 0.92 20 2.75 12.4 406 132 59 23.3 0.88 16 2.82 12.7 419 136 22.6 0.84 17 2.80 12.6 415 135 20.8 0.81 17 2.73 12.3 402 131 24.4 0.90 17 2.91 13.1 455 146 23.6 0.86 18 2.88 13.0 451 145 21.8 0.83 18 2.81 12.7 437 140 63 24.1 0.74 14 2.88 13.0 451 145 23.4 0.70 14 2.86 12.9 446 143 21.6 0.68 15 2.79 12.6 433 139 71 26.4 28.3 0.68 0.44 14 10 3.00 3.10 13.5 13.9 481 501 160 170 25.6 27.5 0.65 0.42 15 10 2.97 3.07 13.4 13.8 476 496 158 168 23.6 25.4 0.63 0.40 15 10 2.90 3.00 13.0 13.5 462 481 153 163 67 26.4 0.51 11 2.97 13.4 476 158 25.6 0.49 11 2.95 13.3 471 156 23.7 0.47 11 2.88 12.9 457 152 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 25.5 1.00 20 2.75 12.2 383 133 24.8 0.95 21 2.73 12.1 379 132 22.9 0.92 21 2.67 11.8 368 128 59 25.1 0.88 17 2.73 12.1 379 132 24.4 0.84 18 2.71 12.0 375 130 22.5 0.81 18 2.64 11.7 364 126 105ºF Product Specifications Expanded Cooling Data — GPH1330M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 29.9 1.00 23 2.25 9.7 239 112 29.1 0.96 24 2.23 9.6 236 111 26.8 0.93 25 2.18 9.4 229 108 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 920 1050 1180 59 29.4 0.96 22 2.23 9.6 236 111 28.6 0.92 23 2.22 9.6 234 110 26.4 0.88 23 2.17 9.4 227 107 Airflow MBh S/T ∆T kW 1180 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1050 Amps Hi Pr Lo Pr MBh S/T ∆T 920 kW Amps Hi Pr Lo Pr 30.5 0.97 23 2.30 9.9 257 119 29.6 0.93 24 2.28 9.8 255 118 27.3 0.89 24 2.23 9.6 247 115 63 30.1 0.90 21 2.28 9.8 255 118 29.2 0.86 22 2.26 9.8 252 117 26.9 0.83 22 2.21 9.5 244 113 31.9 0.88 22 2.37 10.2 271 130 31.0 0.84 23 2.35 10.1 269 129 28.6 0.81 23 2.29 9.9 261 125 67 32.1 0.73 18 2.35 10.1 269 129 31.2 0.70 19 2.33 10.0 266 128 28.8 0.67 19 2.28 9.8 258 124 34.1 0.71 19 2.44 10.5 283 139 33.1 0.68 20 2.42 10.4 280 137 30.5 0.65 20 2.36 10.2 272 133 71 34.3 0.55 15 2.42 10.4 280 137 33.3 0.52 15 2.40 10.3 278 136 30.8 0.50 15 2.34 10.1 269 132 29.2 1.00 23 2.42 10.4 268 119 28.4 1.00 25 2.40 10.3 265 117 26.2 0.96 25 2.34 10.0 257 114 59 28.7 1.00 22 2.40 10.3 265 117 27.9 0.95 23 2.38 10.2 263 116 25.7 0.92 24 2.32 10.0 255 113 29.8 1.00 23 2.46 10.6 288 126 28.9 0.96 24 2.45 10.5 286 125 26.7 0.93 25 2.39 10.2 277 121 63 29.4 0.93 21 2.45 10.5 286 125 28.5 0.89 22 2.43 10.4 283 124 26.3 0.86 23 2.37 10.2 274 120 71 33.5 0.57 15 2.60 11.1 315 145 32.6 0.54 15 2.58 11.0 311 144 30.0 0.52 16 2.52 10.8 302 139 31.2 33.3 0.91 0.74 22 19 2.54 2.62 10.9 11.2 305 318 138 147 30.3 32.3 0.87 0.70 23 20 2.52 2.60 10.8 11.1 302 315 136 145 28.0 29.8 0.84 0.68 23 20 2.46 2.54 10.5 10.9 293 305 132 141 67 31.4 0.76 19 2.52 10.8 302 136 30.5 0.72 19 2.50 10.7 299 135 28.1 0.70 20 2.44 10.5 290 131 75ºF 28.5 1.00 22 2.56 11.1 305 123 27.7 1.00 24 2.54 11.0 302 122 25.6 0.98 25 2.48 10.8 293 118 59 28.0 1.00 22 2.54 11.0 302 122 27.2 0.97 23 2.52 10.9 299 121 25.1 0.94 24 2.46 10.7 290 117 29.1 1.00 23 2.61 11.3 328 131 28.2 0.99 24 2.59 11.2 325 130 26.1 0.95 25 2.53 11.0 315 126 30.5 0.93 22 2.70 11.7 346 143 29.6 0.89 23 2.67 11.6 343 142 27.3 0.86 23 2.61 11.3 333 137 32.5 0.76 19 2.78 12.0 361 152 31.6 0.72 20 2.76 11.9 358 151 29.1 0.70 20 2.69 11.7 347 146 27.8 1.00 22 2.69 11.8 347 129 27.0 1.00 24 2.67 11.7 344 128 24.9 1.00 25 2.60 11.4 333 124 28.4 1.00 22 2.75 12.0 374 138 27.6 1.00 24 2.72 11.9 370 136 25.4 0.98 25 2.66 11.6 359 132 29.7 0.96 22 2.83 12.3 395 150 28.9 0.92 23 2.81 12.2 391 149 26.6 0.88 24 2.74 12.0 379 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 28.7 30.6 32.7 27.4 28.0 29.9 0.96 0.78 0.58 1.00 1.00 0.80 21 19 15 21 22 19 2.59 2.67 2.76 2.67 2.72 2.81 11.2 11.6 11.9 11.7 11.9 12.2 325 343 358 344 370 391 130 142 151 128 136 149 27.8 29.7 31.8 26.6 27.1 29.0 0.91 0.74 0.56 1.00 0.94 0.77 22 19 15 23 22 19 2.57 2.65 2.74 2.65 2.70 2.79 11.2 11.5 11.8 11.6 11.8 12.1 322 340 354 340 366 387 128 140 149 127 135 147 25.7 27.4 29.3 24.5 25.1 26.8 0.88 0.72 0.54 0.97 0.91 0.74 23 20 16 24 23 20 2.51 2.59 2.67 2.58 2.64 2.72 10.9 11.2 11.6 11.3 11.5 11.9 312 329 344 330 355 375 125 136 145 123 131 143 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 31.7 0.78 19 2.92 12.7 411 160 30.8 0.74 20 2.90 12.6 407 158 28.4 0.72 20 2.83 12.3 395 154 71 31.9 0.60 15 2.90 12.6 407 158 31.0 0.57 16 2.88 12.5 403 157 28.6 0.55 16 2.81 12.2 391 152 27.0 1.00 21 2.86 12.7 420 144 26.2 1.00 23 2.83 12.6 416 143 24.2 1.00 24 2.77 12.3 404 139 63 26.6 1.00 21 2.83 12.6 416 143 25.8 0.98 22 2.81 12.5 412 141 23.8 0.94 22 2.74 12.2 400 137 28.2 1.00 22 2.95 13.0 444 157 27.4 0.95 23 2.92 12.9 439 156 25.3 0.92 23 2.85 12.6 426 151 67 28.4 0.83 18 2.92 12.9 439 156 27.6 0.80 19 2.90 12.8 435 154 25.4 0.77 20 2.83 12.5 422 150 30.1 0.81 19 3.04 13.5 463 168 29.2 0.77 20 3.02 13.3 458 166 27.0 0.75 20 2.95 13.0 445 161 71 30.3 0.62 15 3.02 13.3 458 166 29.5 0.60 15 2.99 13.2 454 164 27.2 0.57 16 2.92 12.9 440 159 24.5 1.00 19 2.89 13.0 432 140 23.8 1.00 21 2.87 12.9 427 139 22.0 1.00 22 2.80 12.6 414 135 59 24.1 1.00 19 2.87 12.9 427 139 23.4 1.00 20 2.85 12.8 423 137 21.6 1.01 22 2.78 12.5 410 133 25.0 1.00 19 2.95 13.3 464 149 24.2 1.00 21 2.93 13.2 460 148 22.4 1.00 22 2.86 12.9 446 143 63 24.6 1.00 19 2.93 13.2 460 148 23.9 0.99 21 2.91 13.1 455 146 22.0 0.95 21 2.84 12.8 442 142 26.2 27.9 1.00 0.82 20 18 3.05 3.15 13.7 14.2 490 511 163 173 25.4 27.1 0.96 0.78 21 18 3.02 3.12 13.6 14.0 486 506 161 172 23.4 25.0 0.93 0.75 22 19 2.95 3.05 13.3 13.7 471 491 156 167 67 71 26.3 28.1 0.84 0.63 17 14 3.02 3.12 13.6 14.0 486 506 161 172 25.5 27.3 0.80 0.60 18 14 3.00 3.10 13.5 13.9 481 501 160 170 23.6 25.2 0.77 0.58 18 15 2.93 3.02 13.2 13.6 466 486 155 165 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 26.4 1.00 21 2.80 12.4 391 136 25.7 1.00 22 2.78 12.3 387 134 23.7 1.00 24 2.71 12.0 375 130 59 26.0 1.00 20 2.78 12.3 387 134 25.2 1.00 22 2.75 12.2 383 133 23.3 1.01 23 2.69 11.9 371 129 105ºF Product Specifications Expanded Cooling Data — GPH1330M41A* (cont.) 7 8 www.amana-hac.com 34.5 0.84 21 2.54 10.7 240 113 33.5 0.80 21 2.52 10.6 237 112 30.9 0.77 22 2.46 10.3 230 108 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 1008 1150 1292 59 33.9 0.74 18 2.52 10.6 237 112 32.9 0.70 19 2.50 10.5 235 111 30.4 0.68 19 2.45 10.3 228 107 Airflow MBh S/T ∆T kW 1292 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1150 Amps Hi Pr Lo Pr MBh S/T ∆T 1008 kW Amps Hi Pr Lo Pr 35.5 0.75 19 2.59 10.9 258 120 34.5 0.72 20 2.57 10.8 255 119 31.8 0.69 20 2.51 10.5 248 115 63 35.1 0.62 15 2.57 10.8 255 119 34.1 0.59 16 2.55 10.7 253 118 31.5 0.57 16 2.49 10.5 245 114 38.4 0.57 16 2.67 11.2 272 131 37.3 0.54 16 2.65 11.1 270 130 34.4 0.52 16 2.59 10.8 262 126 67 38.5 0.43 12 2.65 11.1 270 130 37.4 0.41 12 2.63 11.0 267 129 34.5 0.39 12 2.57 10.8 259 125 41.2 0.37 11 2.75 11.5 284 140 40.0 0.35 11 2.73 11.4 281 138 37.0 0.34 11 2.67 11.2 273 134 71 33.7 0.87 21 2.72 11.4 269 119 32.7 0.83 22 2.70 11.3 266 118 30.2 0.80 22 2.64 11.0 258 115 59 33.1 0.76 18 2.70 11.3 266 118 32.2 0.73 19 2.68 11.2 264 117 29.7 0.70 19 2.62 11.0 256 113 34.7 0.78 19 2.78 11.6 289 127 33.7 0.74 20 2.76 11.5 287 126 31.1 0.71 20 2.70 11.3 278 122 63 34.3 0.64 16 2.76 11.5 287 126 33.3 0.61 16 2.74 11.4 284 124 30.8 0.59 16 2.67 11.2 275 121 37.5 0.59 16 2.86 12.0 306 139 36.4 0.56 16 2.84 11.9 303 137 33.6 0.54 17 2.78 11.6 294 133 67 37.6 0.44 12 2.84 11.9 303 137 36.5 0.42 12 2.82 11.8 300 136 33.7 0.41 13 2.75 11.5 291 132 75ºF 40.3 0.38 11 2.95 12.3 319 148 39.1 0.36 11 2.93 12.2 316 146 36.1 0.35 11 2.86 11.9 306 142 71 32.9 0.89 21 2.89 12.2 306 124 31.9 0.85 22 2.86 12.1 303 123 29.5 0.82 22 2.80 11.8 294 119 59 32.3 0.78 18 2.86 12.1 303 123 31.4 0.75 19 2.84 12.0 300 122 29.0 0.72 19 2.78 11.8 291 118 33.8 0.80 19 2.95 12.5 329 132 32.9 0.76 20 2.92 12.4 326 131 30.3 0.73 20 2.86 12.1 316 127 36.6 0.60 16 3.04 12.8 348 144 35.6 0.58 16 3.01 12.7 344 143 32.8 0.55 17 2.94 12.4 334 138 39.3 0.39 11 3.13 13.3 363 153 38.2 0.37 11 3.11 13.2 359 152 35.2 0.36 11 3.04 12.8 348 147 32.1 0.92 21 3.03 13.0 348 130 31.1 0.88 22 3.01 12.9 345 129 28.7 0.85 22 2.94 12.5 335 125 33.0 0.82 19 3.09 13.2 375 139 32.1 0.78 20 3.07 13.1 371 137 29.6 0.76 20 3.00 12.8 360 133 35.7 0.62 16 3.19 13.6 396 151 34.7 0.59 16 3.17 13.5 392 150 32.0 0.57 17 3.09 13.2 380 145 38.4 0.40 11 3.29 14.1 413 161 37.2 0.38 11 3.27 14.0 409 160 34.4 0.37 12 3.19 13.6 397 155 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 33.5 36.7 31.5 32.7 35.8 0.65 0.45 0.81 0.68 0.47 16 12 18 16 12 2.92 3.01 3.01 3.07 3.17 12.4 12.7 12.9 13.1 13.5 326 344 345 371 392 131 143 129 137 150 32.5 35.6 30.6 31.7 34.8 0.62 0.43 0.77 0.64 0.45 16 12 19 16 12 2.90 2.99 2.98 3.05 3.14 12.3 12.6 12.8 13.0 13.4 323 341 341 367 388 129 141 128 136 148 30.0 32.9 28.3 29.3 32.1 0.60 0.42 0.74 0.62 0.43 16 13 19 17 13 2.83 2.92 2.91 2.97 3.07 12.0 12.3 12.4 12.7 13.1 313 330 331 356 376 125 137 124 132 144 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 63 31.1 0.70 15 3.19 13.9 418 144 30.2 0.67 16 3.17 13.8 413 142 27.8 0.65 16 3.09 13.4 401 138 34.0 0.65 16 3.32 14.4 445 159 33.0 0.62 16 3.30 14.3 441 157 30.4 0.59 16 3.22 13.9 428 152 67 34.0 0.49 12 3.29 14.3 441 157 33.0 0.46 12 3.27 14.2 437 155 30.5 0.45 12 3.19 13.8 423 151 36.4 0.42 11 3.43 14.9 465 169 35.4 0.40 11 3.40 14.8 460 167 32.7 0.38 11 3.32 14.4 446 162 71 28.2 0.96 19 3.26 14.4 433 141 27.4 0.92 20 3.23 14.3 429 140 25.3 0.89 20 3.15 13.9 416 136 59 27.8 0.85 17 3.23 14.3 429 140 26.9 0.81 17 3.21 14.2 424 138 24.9 0.78 18 3.13 13.8 412 134 29.1 0.86 18 3.33 14.7 466 150 28.2 0.82 19 3.30 14.6 461 149 26.0 0.79 19 3.22 14.2 448 144 63 28.8 0.71 14 3.30 14.6 461 149 27.9 0.67 15 3.27 14.5 457 147 25.8 0.65 15 3.20 14.1 443 143 71 31.5 33.8 0.65 0.42 15 10 3.43 3.55 15.2 15.7 492 513 164 175 30.5 32.8 0.62 0.40 15 10 3.41 3.52 15.0 15.5 487 508 162 173 28.2 30.3 0.60 0.39 15 11 3.32 3.43 14.7 15.2 473 493 157 168 67 31.5 0.49 11 3.41 15.0 487 162 30.6 0.47 11 3.38 14.9 482 161 28.2 0.45 12 3.30 14.5 468 156 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 30.5 31.4 0.95 0.85 21 19 3.15 3.22 13.7 14.0 392 422 137 145 29.6 30.5 0.91 0.81 22 20 3.13 3.19 13.6 13.9 388 418 135 144 27.3 28.1 0.88 0.79 22 20 3.05 3.12 13.2 13.5 376 405 131 139 59 30.0 0.84 18 3.13 13.6 388 135 29.1 0.80 19 3.10 13.5 384 134 26.9 0.77 19 3.03 13.1 373 130 105ºF Product Specifications Expanded Cooling Data — GPH1336M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 35.7 0.96 24 2.58 10.8 245 115 34.7 0.92 25 2.56 10.7 242 114 32.0 0.89 26 2.50 10.5 235 111 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 1008 1150 1292 59 35.1 0.92 23 2.56 10.7 242 114 34.1 0.88 24 2.54 10.7 240 113 31.4 0.85 24 2.48 10.4 233 110 Airflow MBh S/T ∆T kW 1292 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1150 Amps Hi Pr Lo Pr MBh S/T ∆T 1008 kW Amps Hi Pr Lo Pr 36.4 0.93 24 2.63 11.0 263 123 35.3 0.89 25 2.61 11.0 261 121 32.6 0.86 25 2.55 10.7 253 118 63 35.9 0.86 22 2.61 11.0 261 121 34.8 0.82 23 2.59 10.9 258 120 32.1 0.79 23 2.53 10.6 250 117 38.1 0.84 23 2.71 11.4 278 134 37.0 0.80 24 2.69 11.3 275 132 34.2 0.77 24 2.63 11.0 267 129 67 38.3 0.70 19 2.69 11.3 275 132 37.2 0.67 20 2.67 11.2 272 131 34.3 0.65 20 2.61 10.9 264 127 40.7 0.68 20 2.79 11.7 290 143 39.5 0.65 21 2.77 11.6 287 141 36.4 0.63 21 2.71 11.4 278 137 71 41.0 0.52 15 2.77 11.6 287 141 39.8 0.50 16 2.75 11.5 284 140 36.7 0.48 16 2.69 11.3 276 136 34.9 1.00 25 2.77 11.6 274 122 33.9 0.95 26 2.75 11.5 272 121 31.3 0.92 26 2.68 11.2 264 117 59 34.3 0.95 23 2.75 11.5 272 121 33.3 0.91 24 2.72 11.4 269 119 30.7 0.88 25 2.66 11.1 261 116 35.6 0.96 24 2.82 11.8 295 130 34.5 0.92 25 2.80 11.7 292 128 31.9 0.89 26 2.74 11.4 284 124 63 35.0 0.89 22 2.80 11.7 292 128 34.0 0.85 23 2.78 11.6 289 127 31.4 0.82 24 2.72 11.4 281 123 37.2 0.87 23 2.91 12.1 312 141 36.1 0.83 24 2.89 12.0 309 140 33.4 0.80 24 2.82 11.8 299 136 67 37.4 0.73 19 2.89 12.0 309 140 36.3 0.69 20 2.86 12.0 306 139 33.5 0.67 20 2.80 11.7 297 134 75ºF 39.7 0.71 20 3.00 12.5 325 151 38.6 0.67 21 2.98 12.4 322 149 35.6 0.65 21 2.91 12.1 312 145 71 40.0 0.54 15 2.98 12.4 322 149 38.8 0.52 16 2.95 12.3 319 148 35.8 0.50 16 2.88 12.0 309 143 34.0 1.00 24 2.93 12.4 312 127 33.1 0.98 26 2.91 12.3 309 125 30.5 0.94 26 2.84 12.0 300 121 59 33.5 1.00 24 2.91 12.3 309 125 32.5 0.93 24 2.89 12.2 306 124 30.0 0.90 25 2.82 11.9 297 120 34.7 0.99 24 2.99 12.7 336 135 33.7 0.94 25 2.97 12.6 333 133 31.1 0.91 26 2.90 12.3 323 129 36.3 0.89 23 3.09 13.1 355 147 35.3 0.85 24 3.06 12.9 351 145 32.6 0.82 24 2.99 12.6 341 141 38.8 0.72 20 3.18 13.5 370 156 37.6 0.69 21 3.16 13.4 366 155 34.7 0.67 21 3.08 13.1 355 150 33.2 1.00 24 3.08 13.2 355 133 32.2 1.00 26 3.05 13.1 352 132 29.8 0.97 26 2.98 12.7 341 128 33.9 1.00 24 3.14 13.4 383 141 32.9 0.97 26 3.12 13.3 379 140 30.3 0.94 26 3.04 13.0 367 136 35.5 0.92 23 3.24 13.8 404 154 34.4 0.88 24 3.22 13.7 400 153 31.8 0.85 25 3.14 13.4 388 148 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.0 32.6 33.4 35.6 0.92 0.75 0.56 1.00 0.95 0.77 22 19 15 23 22 20 2.97 3.06 3.16 3.05 3.12 3.22 12.6 12.9 13.4 13.1 13.3 13.7 333 351 366 352 379 400 133 145 155 132 140 153 33.2 35.5 37.9 31.7 32.4 34.6 0.87 0.71 0.53 0.96 0.90 0.73 23 20 16 24 23 20 2.95 3.04 3.13 3.03 3.09 3.19 12.5 12.8 13.3 13.0 13.2 13.6 329 348 363 348 375 396 132 144 153 130 139 151 30.6 32.7 35.0 29.3 29.9 31.9 0.84 0.69 0.51 0.93 0.87 0.71 24 20 16 25 24 21 2.88 2.97 3.06 2.96 3.02 3.12 12.2 12.5 12.9 12.6 12.9 13.3 319 337 352 338 364 384 128 140 149 126 134 147 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 37.8 0.75 20 3.35 14.3 421 164 36.7 0.71 21 3.32 14.2 417 163 33.9 0.69 21 3.24 13.8 405 158 71 38.1 0.58 16 3.32 14.2 417 163 37.0 0.55 16 3.29 14.1 413 161 34.1 0.53 16 3.21 13.7 401 156 32.2 1.00 23 3.27 14.2 430 148 31.2 1.00 25 3.25 14.1 426 147 28.8 0.97 26 3.17 13.7 413 142 63 31.7 1.00 23 3.25 14.1 426 147 30.8 0.94 23 3.22 14.0 422 145 28.4 0.90 23 3.14 13.6 409 141 71 36.2 0.60 15 3.46 15.0 469 171 35.1 0.57 16 3.43 14.9 465 169 32.4 0.55 16 3.35 14.5 451 164 33.7 35.9 0.96 0.78 23 20 3.38 3.49 14.6 15.1 454 474 162 172 32.7 34.9 0.91 0.74 24 21 3.35 3.46 14.5 15.0 450 469 160 171 30.2 32.2 0.88 0.71 24 21 3.27 3.37 14.2 14.6 436 455 155 165 67 33.9 0.80 19 3.35 14.5 450 160 32.9 0.76 20 3.32 14.4 445 159 30.3 0.74 20 3.24 14.0 432 154 29.2 1.00 21 3.31 14.6 442 144 28.4 1.00 23 3.28 14.5 437 143 26.2 1.00 24 3.21 14.2 424 138 59 28.7 1.00 20 3.28 14.5 437 143 27.9 1.00 22 3.26 14.4 433 141 25.7 0.97 23 3.18 14.0 420 137 29.8 1.00 21 3.38 15.0 475 153 28.9 1.00 23 3.36 14.8 471 152 26.7 0.98 24 3.27 14.5 457 147 63 29.4 1.00 21 3.36 14.8 471 152 28.5 0.94 22 3.33 14.7 466 150 26.3 0.91 22 3.25 14.4 452 146 31.2 0.96 21 3.49 15.4 502 167 30.3 0.92 22 3.46 15.3 497 166 28.0 0.89 23 3.38 14.9 482 161 33.3 0.78 19 3.61 15.9 524 178 32.3 0.75 19 3.58 15.8 518 176 29.8 0.72 20 3.49 15.4 503 171 67 71 31.4 33.5 0.81 0.60 18 14 3.46 3.58 15.3 15.8 497 518 166 176 30.4 32.5 0.77 0.57 19 15 3.43 3.55 15.2 15.7 492 513 164 175 28.1 30.0 0.74 0.55 19 15 3.35 3.46 14.8 15.3 477 498 159 169 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 31.6 1.00 22 3.20 13.9 400 139 30.6 1.00 24 3.18 13.8 396 138 28.3 1.00 26 3.10 13.5 384 134 59 31.0 1.00 22 3.18 13.8 396 138 30.1 1.00 24 3.15 13.7 392 137 27.8 0.96 24 3.08 13.4 380 132 105ºF Product Specifications Expanded Cooling Data — GPH1336M41A* (cont.) 9 10 www.amana-hac.com 39.9 0.83 21 2.88 12.6 229 107 38.7 0.79 22 2.86 12.5 227 106 35.7 0.77 22 2.80 12.3 220 103 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 1139 1300 1461 59 39.2 0.73 18 2.86 12.5 227 106 38.1 0.70 19 2.84 12.4 225 105 35.1 0.67 19 2.77 12.2 218 102 Airflow MBh S/T ∆T kW 1461 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1300 Amps Hi Pr Lo Pr MBh S/T ∆T 1139 kW Amps Hi Pr Lo Pr 41.0 0.74 19 2.94 12.9 247 114 39.8 0.71 20 2.92 12.8 244 113 36.8 0.68 20 2.85 12.5 237 109 63 40.6 0.61 16 2.91 12.8 244 113 39.4 0.58 16 2.89 12.7 242 111 36.4 0.56 17 2.83 12.4 234 108 44.4 0.56 16 3.02 13.2 260 124 43.1 0.54 16 3.00 13.1 258 123 39.8 0.52 17 2.93 12.8 250 119 67 44.5 0.42 12 3.00 13.1 258 123 43.2 0.40 12 2.98 13.0 255 122 39.9 0.39 13 2.91 12.7 248 118 47.7 0.36 11 3.11 13.6 272 132 46.3 0.35 11 3.09 13.5 269 131 42.7 0.33 11 3.02 13.2 261 127 71 38.9 0.86 21 3.09 13.5 257 113 37.8 0.82 22 3.06 13.4 255 112 34.9 0.79 22 2.99 13.1 247 108 59 38.3 0.76 18 3.06 13.4 255 112 37.2 0.72 19 3.04 13.3 252 111 34.3 0.70 19 2.97 13.0 244 107 40.1 0.77 19 3.15 13.8 277 120 38.9 0.74 20 3.12 13.7 274 119 35.9 0.71 21 3.05 13.3 266 115 63 39.7 0.63 16 3.12 13.7 274 119 38.5 0.60 16 3.10 13.5 271 118 35.6 0.58 17 3.03 13.2 263 114 43.4 0.58 16 3.24 14.1 292 131 42.1 0.56 17 3.22 14.0 289 130 38.9 0.54 17 3.14 13.7 281 126 67 43.5 0.44 12 3.22 14.0 289 130 42.2 0.42 13 3.19 13.9 286 129 39.0 0.40 13 3.12 13.6 278 125 75ºF 46.6 0.38 11 3.34 14.6 305 140 45.2 0.36 11 3.32 14.5 302 138 41.7 0.35 12 3.24 14.1 293 134 71 38.0 0.88 21 3.27 14.5 292 117 36.9 0.84 22 3.24 14.4 290 116 34.1 0.81 22 3.17 14.0 281 113 59 37.4 0.78 18 3.24 14.4 290 116 36.3 0.74 19 3.22 14.2 287 115 33.5 0.72 19 3.14 13.9 278 112 39.1 0.79 19 3.34 14.8 315 125 38.0 0.75 20 3.31 14.7 312 124 35.1 0.73 21 3.23 14.3 302 120 42.4 0.60 16 3.44 15.2 332 136 41.1 0.57 17 3.41 15.1 329 135 38.0 0.55 17 3.33 14.7 319 131 45.5 0.39 11 3.55 15.7 347 145 44.1 0.37 11 3.52 15.6 343 144 40.7 0.35 12 3.43 15.2 333 139 37.1 0.91 21 3.43 15.3 333 123 36.0 0.87 22 3.40 15.2 330 122 33.2 0.84 23 3.32 14.8 320 118 38.2 0.82 20 3.50 15.6 358 131 37.1 0.78 20 3.47 15.5 355 130 34.2 0.75 21 3.39 15.2 344 126 41.3 0.62 16 3.61 16.1 379 143 40.1 0.59 17 3.58 16.0 375 142 37.0 0.57 17 3.50 15.6 364 137 44.4 0.40 11 3.72 16.6 395 152 43.1 0.38 12 3.69 16.5 391 151 39.7 0.37 12 3.61 16.1 379 146 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 38.7 42.4 36.5 37.8 41.4 0.65 0.45 0.80 0.67 0.46 16 12 18 16 12 3.31 3.41 3.40 3.47 3.58 14.7 15.1 15.2 15.5 16.0 312 329 330 355 375 124 135 122 130 142 37.6 41.2 35.4 36.7 40.2 0.62 0.43 0.77 0.64 0.44 16 13 19 17 13 3.28 3.38 3.38 3.45 3.55 14.5 15.0 15.1 15.4 15.8 308 326 327 351 371 122 134 121 129 140 34.7 38.0 32.7 33.9 37.1 0.60 0.41 0.74 0.62 0.43 17 13 19 17 13 3.21 3.31 3.30 3.37 3.47 14.2 14.6 14.7 15.0 15.5 299 316 317 341 360 119 130 117 125 136 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 36.3 0.85 19 3.64 16.5 403 137 35.2 0.81 20 3.61 16.4 399 136 32.5 0.78 20 3.53 16.0 387 132 63 35.9 0.70 16 3.61 16.4 399 136 34.9 0.66 16 3.58 16.3 395 135 32.2 0.64 17 3.50 15.9 383 131 39.3 0.64 16 3.76 17.0 426 150 38.1 0.61 16 3.73 16.9 422 149 35.2 0.59 17 3.64 16.5 409 144 67 39.3 0.48 12 3.73 16.9 422 148 38.2 0.46 12 3.70 16.7 417 147 35.2 0.44 13 3.61 16.3 405 143 42.1 0.41 11 3.88 17.6 444 160 40.9 0.39 11 3.84 17.4 440 158 37.8 0.38 12 3.75 17.0 427 153 71 32.6 0.96 20 3.68 17.0 414 134 31.7 0.91 20 3.66 16.9 410 132 29.2 0.88 21 3.57 16.5 398 128 59 32.1 0.84 17 3.65 16.9 410 132 31.2 0.80 18 3.63 16.7 406 131 28.8 0.77 18 3.54 16.3 394 127 33.6 0.86 18 3.76 17.4 446 142 32.6 0.82 19 3.73 17.2 441 141 30.1 0.79 19 3.64 16.8 428 136 63 33.3 0.70 15 3.73 17.2 441 141 32.3 0.67 15 3.70 17.1 437 139 29.8 0.65 16 3.61 16.7 424 135 71 36.4 39.0 0.65 0.42 15 10 3.88 4.01 17.9 18.5 471 491 155 165 35.3 37.9 0.62 0.40 15 11 3.85 3.97 17.8 18.4 466 486 154 164 32.6 35.0 0.60 0.38 16 11 3.76 3.88 17.3 17.9 452 471 149 159 67 36.4 0.49 11 3.85 17.8 466 154 35.4 0.46 12 3.82 17.6 461 152 32.7 0.45 12 3.73 17.2 447 148 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 35.2 0.95 21 3.57 16.2 375 129 34.2 0.90 22 3.54 16.0 371 128 31.6 0.87 22 3.45 15.7 360 124 59 34.6 0.83 18 3.54 16.0 371 128 33.6 0.80 19 3.51 15.9 367 127 31.0 0.77 19 3.43 15.5 356 123 105ºF Product Specifications Expanded Cooling Data — GPH1342M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 1139 1300 1461 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr Airflow MBh S/T ∆T kW 1461 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1300 Amps Hi Pr Lo Pr MBh S/T ∆T 1139 kW Amps Hi Pr Lo Pr 63 41.5 0.86 22 2.96 13.0 249 115 40.2 0.82 23 2.94 12.9 247 114 37.1 0.79 24 2.87 12.6 239 110 41.3 42.1 0.96 0.92 25 24 2.92 2.98 12.8 13.1 234 252 109 116 40.1 40.9 0.91 0.88 26 25 2.90 2.96 12.7 13.0 232 249 108 115 37.0 37.7 0.88 0.85 26 26 2.84 2.89 12.4 12.7 225 242 105 111 59 40.6 0.91 23 2.90 12.7 232 108 39.4 0.87 24 2.88 12.6 229 107 36.4 0.84 25 2.82 12.3 222 104 44.1 0.83 23 3.07 13.4 266 127 42.8 0.80 24 3.05 13.3 263 125 39.5 0.77 24 2.98 13.0 255 122 67 44.3 0.70 19 3.05 13.3 263 125 43.0 0.66 20 3.02 13.2 260 124 39.7 0.64 21 2.96 12.9 253 120 47.0 0.68 20 3.16 13.9 277 135 45.6 0.65 21 3.14 13.8 274 134 42.1 0.62 21 3.07 13.4 266 129 71 47.3 0.52 16 3.14 13.8 274 134 46.0 0.50 16 3.11 13.7 272 132 42.4 0.48 16 3.04 13.3 264 128 40.3 0.99 25 3.13 13.7 262 115 39.1 0.95 26 3.11 13.6 260 114 36.1 0.91 27 3.04 13.3 252 111 59 39.6 0.95 24 3.11 13.6 260 114 38.5 0.90 25 3.09 13.5 257 113 35.5 0.87 25 3.02 13.2 249 110 41.1 0.96 25 3.20 14.0 282 123 39.9 0.91 26 3.17 13.9 280 121 36.8 0.88 26 3.10 13.5 271 118 63 40.5 0.89 23 3.17 13.9 280 121 39.3 0.85 24 3.15 13.8 277 120 36.3 0.82 24 3.08 13.4 268 117 43.0 0.86 23 3.29 14.4 298 134 41.8 0.82 24 3.27 14.3 295 132 38.6 0.79 25 3.19 13.9 286 128 67 43.3 0.72 20 3.27 14.3 295 132 42.0 0.69 20 3.24 14.1 292 131 38.8 0.66 21 3.17 13.8 284 127 75ºF 45.9 0.70 20 3.40 14.8 311 142 44.6 0.67 21 3.37 14.7 308 141 41.2 0.64 21 3.29 14.4 299 137 71 46.2 0.54 16 3.37 14.7 308 141 44.9 0.51 16 3.34 14.6 305 140 41.4 0.50 17 3.27 14.3 296 135 39.4 1.00 25 3.32 14.7 298 120 38.2 0.97 26 3.29 14.6 295 119 35.3 0.94 27 3.22 14.2 287 115 59 38.7 0.97 24 3.29 14.6 295 119 37.6 0.93 25 3.27 14.5 293 117 34.7 0.89 25 3.19 14.1 284 114 40.1 0.98 25 3.39 15.0 321 127 39.0 0.94 26 3.36 14.9 318 126 36.0 0.90 26 3.28 14.5 308 122 42.0 0.89 23 3.49 15.4 339 139 40.8 0.84 24 3.47 15.3 336 138 37.7 0.81 25 3.38 14.9 326 134 44.8 0.72 20 3.60 15.9 354 148 43.5 0.69 21 3.57 15.8 350 147 40.2 0.66 21 3.49 15.4 340 142 38.4 1.00 24 3.48 15.6 340 126 37.3 1.00 26 3.46 15.4 336 124 34.4 0.97 27 3.38 15.1 326 121 39.1 1.00 25 3.56 15.9 366 134 38.0 0.97 26 3.53 15.8 362 132 35.1 0.93 26 3.45 15.4 351 128 41.0 0.91 24 3.67 16.4 386 146 39.8 0.87 25 3.64 16.2 382 145 36.7 0.84 25 3.55 15.8 371 140 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.5 42.2 45.1 37.7 38.6 41.2 0.91 0.74 0.55 1.00 0.94 0.76 23 20 16 24 23 20 3.36 3.47 3.57 3.46 3.53 3.64 14.9 15.3 15.8 15.4 15.8 16.2 318 336 350 336 362 382 126 138 147 124 132 145 38.4 41.0 43.8 36.6 37.4 40.0 0.87 0.71 0.53 0.96 0.90 0.73 24 20 16 25 24 21 3.34 3.44 3.55 3.43 3.50 3.61 14.8 15.2 15.7 15.3 15.6 16.1 315 332 347 333 359 379 125 136 145 123 131 143 35.4 37.8 40.5 33.8 34.6 36.9 0.84 0.68 0.51 0.92 0.86 0.70 24 21 17 25 24 21 3.26 3.36 3.46 3.35 3.42 3.52 14.4 14.8 15.3 15.0 15.3 15.7 305 322 336 323 348 367 121 132 141 120 127 139 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 43.7 0.74 20 3.78 16.9 403 156 42.5 0.71 21 3.75 16.8 399 154 39.2 0.68 22 3.66 16.4 387 149 71 44.0 0.57 16 3.75 16.8 399 154 42.8 0.55 16 3.72 16.6 395 152 39.5 0.53 17 3.64 16.2 383 148 37.2 1.00 23 3.70 16.8 411 140 36.1 1.00 26 3.67 16.7 407 139 33.3 0.97 26 3.58 16.3 395 135 63 36.6 1.00 23 3.67 16.7 407 139 35.6 0.93 23 3.64 16.5 403 137 32.8 0.90 24 3.55 16.1 391 133 38.9 0.95 23 3.82 17.3 434 153 37.8 0.91 24 3.79 17.1 430 152 34.9 0.87 25 3.69 16.7 417 147 67 39.1 0.79 20 3.79 17.1 430 152 38.0 0.76 20 3.76 17.0 426 150 35.1 0.73 21 3.67 16.6 413 146 41.5 0.77 20 3.94 17.9 453 163 40.3 0.73 21 3.91 17.7 449 161 37.2 0.71 21 3.81 17.3 435 157 71 41.8 0.59 16 3.91 17.7 449 161 40.6 0.57 16 3.88 17.6 444 160 37.5 0.55 17 3.78 17.1 431 155 33.8 1.00 21 3.74 17.3 422 136 32.8 1.00 23 3.71 17.2 418 135 30.3 1.00 24 3.62 16.7 406 131 59 33.2 1.00 21 3.71 17.2 418 135 32.2 1.00 23 3.68 17.0 414 134 29.8 0.96 23 3.60 16.6 402 130 34.4 1.00 22 3.82 17.7 455 145 33.4 1.00 24 3.79 17.5 450 144 30.9 0.98 24 3.70 17.1 437 139 63 33.9 1.00 21 3.79 17.5 450 144 32.9 0.94 22 3.76 17.4 446 142 30.4 0.90 22 3.67 17.0 432 138 36.1 38.5 0.96 0.78 22 19 3.94 4.07 18.2 18.8 480 501 158 169 35.0 37.4 0.91 0.74 23 20 3.91 4.04 18.0 18.7 475 496 157 167 32.3 34.5 0.88 0.71 23 20 3.82 3.94 17.6 18.2 461 481 152 162 67 71 36.3 38.8 0.80 0.60 18 15 3.91 4.04 18.0 18.7 475 496 157 167 35.2 37.6 0.76 0.57 19 15 3.88 4.01 17.9 18.5 471 491 155 165 32.5 34.7 0.74 0.55 19 15 3.79 3.91 17.5 18.0 456 476 151 160 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 36.5 1.00 23 3.62 16.4 382 132 35.4 1.00 25 3.59 16.3 379 130 32.7 1.00 26 3.51 15.9 367 127 59 35.9 1.00 23 3.59 16.3 379 130 34.8 0.99 24 3.57 16.2 375 129 32.1 0.96 25 3.48 15.8 364 125 105ºF Product Specifications Expanded Cooling Data — GPH1342M41A* (cont.) 11 12 www.amana-hac.com 46.3 0.90 20 3.31 13.8 243 110 45.0 0.86 21 3.29 13.7 241 109 41.5 0.83 21 3.21 13.4 233 105 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 1507 1720 1933 59 45.6 0.80 17 3.29 13.7 240 109 44.2 0.76 18 3.26 13.6 238 108 40.8 0.73 18 3.19 13.3 231 104 Airflow MBh S/T ∆T kW 1933 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1720 Amps Hi Pr Lo Pr MBh S/T ∆T 1507 kW Amps Hi Pr Lo Pr 47.7 0.81 18 3.38 14.1 261 117 46.3 0.77 19 3.36 14.0 259 116 42.8 0.74 19 3.28 13.6 251 112 63 47.2 0.66 15 3.36 14.0 259 116 45.9 0.63 16 3.33 13.8 256 114 42.3 0.61 16 3.25 13.5 249 111 51.6 0.61 15 3.49 14.5 276 127 50.1 0.58 16 3.46 14.4 273 126 46.3 0.56 16 3.38 14.0 265 122 67 51.7 0.46 11 3.46 14.4 273 126 50.2 0.44 12 3.43 14.2 271 125 46.4 0.42 12 3.35 13.9 262 121 55.4 0.39 10 3.60 14.9 288 136 53.8 0.38 11 3.57 14.8 285 134 49.7 0.36 11 3.48 14.5 277 130 71 45.3 0.94 20 3.56 14.7 273 116 43.9 0.89 21 3.53 14.6 270 115 40.6 0.86 21 3.45 14.3 262 111 59 44.5 0.82 17 3.53 14.6 270 115 43.2 0.79 18 3.51 14.5 267 114 39.9 0.76 18 3.42 14.2 259 110 46.6 0.84 19 3.64 15.1 293 123 45.2 0.80 19 3.61 14.9 290 122 41.8 0.77 20 3.52 14.6 282 118 63 46.1 0.69 15 3.61 14.9 290 122 44.8 0.66 16 3.58 14.8 288 121 41.3 0.63 16 3.50 14.5 279 117 50.4 0.63 15 3.75 15.5 310 135 49.0 0.60 16 3.72 15.4 307 133 45.2 0.58 16 3.63 15.0 298 129 67 50.5 0.48 11 3.72 15.4 307 133 49.1 0.45 12 3.69 15.2 304 132 45.3 0.44 12 3.60 14.9 294 128 75ºF 54.1 0.41 11 3.87 16.0 323 143 52.6 0.39 11 3.84 15.9 320 142 48.5 0.38 11 3.75 15.5 310 138 71 44.2 0.96 20 3.78 15.9 310 121 42.9 0.92 21 3.75 15.7 307 119 39.6 0.88 21 3.66 15.4 298 116 59 43.4 0.85 17 3.75 15.7 307 119 42.2 0.81 18 3.72 15.6 304 118 38.9 0.78 18 3.63 15.2 295 115 45.5 0.86 19 3.86 16.2 334 128 44.2 0.82 19 3.83 16.1 330 127 40.8 0.79 20 3.74 15.7 320 123 49.2 0.65 15 3.99 16.7 352 140 47.8 0.62 16 3.95 16.6 349 139 44.1 0.60 16 3.86 16.1 338 134 52.8 0.42 11 4.12 17.2 367 149 51.3 0.40 11 4.08 17.1 364 148 47.4 0.38 11 3.98 16.7 353 143 43.1 0.99 20 3.98 16.8 353 127 41.9 0.95 21 3.94 16.7 350 125 38.6 0.91 21 3.85 16.3 339 122 44.4 0.89 19 4.06 17.2 380 135 43.1 0.85 19 4.03 17.1 376 133 39.8 0.82 20 3.93 16.6 365 129 48.0 0.67 15 4.19 17.7 401 147 46.6 0.64 16 4.16 17.6 397 146 43.0 0.62 16 4.06 17.1 385 141 51.6 0.43 11 4.33 18.3 419 157 50.1 0.41 11 4.29 18.2 414 155 46.2 0.40 11 4.19 17.7 402 150 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 45.0 49.3 42.4 43.9 48.1 0.71 0.49 0.87 0.73 0.50 15 11 18 15 12 3.83 3.95 3.94 4.03 4.16 16.1 16.5 16.7 17.1 17.6 330 349 350 376 397 127 139 125 133 146 43.7 47.9 41.2 42.7 46.7 0.67 0.47 0.83 0.69 0.48 16 12 18 16 12 3.80 3.92 3.91 4.00 4.12 15.9 16.4 16.6 16.9 17.4 327 345 346 372 393 126 137 124 132 144 40.4 44.2 38.0 39.4 43.1 0.65 0.45 0.80 0.67 0.46 16 12 19 16 12 3.71 3.83 3.82 3.90 4.02 15.6 16.0 16.2 16.5 17.0 317 335 336 361 381 122 133 120 128 140 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 42.2 0.92 18 4.23 18.2 427 141 40.9 0.88 19 4.20 18.0 423 140 37.8 0.85 20 4.09 17.6 411 136 63 41.7 0.76 15 4.20 18.0 423 140 40.5 0.72 16 4.16 17.9 419 138 37.4 0.70 16 4.06 17.4 406 134 45.6 0.70 15 4.37 18.7 451 154 44.3 0.66 16 4.33 18.6 447 153 40.9 0.64 16 4.22 18.1 434 148 67 45.7 0.52 11 4.33 18.6 447 153 44.4 0.50 12 4.30 18.4 442 151 41.0 0.48 12 4.19 18.0 429 146 49.0 0.45 10 4.51 19.4 471 164 47.6 0.43 11 4.48 19.2 466 162 43.9 0.41 11 4.36 18.7 452 158 71 37.9 1.00 18 4.28 18.8 439 137 36.8 0.99 19 4.25 18.6 435 136 34.0 0.95 20 4.14 18.1 422 132 59 37.3 0.91 16 4.25 18.6 434 136 36.2 0.87 17 4.21 18.4 430 135 33.4 0.84 17 4.11 18.0 417 130 39.1 0.93 17 4.38 19.2 472 146 37.9 0.89 18 4.34 19.0 468 145 35.0 0.85 18 4.23 18.5 454 140 63 38.7 0.76 14 4.34 19.0 468 145 37.5 0.73 15 4.30 18.8 463 143 34.6 0.70 15 4.20 18.4 449 139 42.3 0.70 14 4.52 19.8 499 159 41.0 0.67 15 4.48 19.6 494 158 37.9 0.65 15 4.37 19.1 479 153 67 42.4 0.53 11 4.48 19.6 494 158 41.1 0.50 11 4.44 19.4 489 156 38.0 0.49 11 4.33 18.9 474 152 115ºF 45.4 0.45 10 4.67 20.4 520 170 44.0 0.43 10 4.63 20.3 515 168 40.7 0.42 10 4.52 19.8 500 163 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 41.0 1.00 19 4.14 17.8 397 133 39.8 0.98 21 4.11 17.7 393 131 36.7 0.95 21 4.01 17.2 382 127 59 40.3 0.91 17 4.11 17.6 393 131 39.1 0.86 18 4.07 17.5 389 130 36.1 0.83 18 3.97 17.1 378 126 105ºF Product Specifications Expanded Cooling Data — GPH1348M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 48.0 1.00 23 3.37 14.0 248 112 46.6 0.99 25 3.34 13.9 245 111 43.0 0.96 25 3.26 13.6 238 108 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 1507 1720 1933 59 47.2 1.00 22 3.34 13.9 245 111 45.8 0.95 23 3.31 13.8 243 110 42.3 0.91 24 3.24 13.5 236 106 Airflow MBh S/T ∆T kW 1933 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1720 Amps Hi Pr Lo Pr MBh S/T ∆T 1507 kW Amps Hi Pr Lo Pr 48.9 1.00 23 3.44 14.3 267 119 47.5 0.96 24 3.41 14.2 264 118 43.8 0.92 25 3.33 13.8 256 114 63 48.2 0.93 21 3.41 14.2 264 118 46.8 0.89 22 3.38 14.1 261 117 43.2 0.86 23 3.30 13.7 254 113 51.2 0.91 22 3.54 14.7 282 130 49.7 0.86 23 3.51 14.6 279 129 45.9 0.83 23 3.43 14.2 270 125 67 51.5 0.76 19 3.51 14.6 279 129 50.0 0.72 19 3.49 14.5 276 127 46.1 0.70 20 3.40 14.1 268 124 54.7 0.73 19 3.65 15.2 294 139 53.1 0.70 20 3.62 15.1 291 137 49.0 0.68 20 3.54 14.7 282 133 71 55.0 0.57 15 3.62 15.1 291 137 53.4 0.54 15 3.60 14.9 288 136 49.3 0.52 16 3.51 14.6 279 132 46.9 1.00 22 3.62 15.0 278 118 45.5 1.00 24 3.59 14.9 275 117 42.0 0.99 25 3.51 14.5 267 114 59 46.1 1.00 22 3.59 14.9 275 117 44.7 0.98 23 3.56 14.7 273 116 41.3 0.94 24 3.48 14.4 264 112 47.8 1.00 23 3.70 15.3 299 126 46.4 0.99 25 3.67 15.2 296 125 42.8 0.96 25 3.58 14.8 287 121 63 47.1 0.96 22 3.67 15.2 296 125 45.7 0.92 22 3.64 15.1 293 123 42.2 0.89 23 3.55 14.7 285 120 50.0 0.94 22 3.81 15.7 316 137 48.6 0.89 23 3.78 15.6 313 136 44.8 0.86 24 3.69 15.2 304 132 67 50.3 0.78 19 3.78 15.6 313 136 48.8 0.75 20 3.75 15.5 310 135 45.1 0.72 20 3.66 15.1 301 131 75ºF 53.4 0.76 19 3.93 16.3 330 146 51.8 0.73 20 3.90 16.1 326 145 47.8 0.70 20 3.81 15.7 317 141 71 53.8 0.59 15 3.90 16.1 326 145 52.2 0.56 16 3.87 16.0 323 143 48.2 0.54 16 3.78 15.6 313 139 45.8 1.00 22 3.84 16.1 316 123 44.4 1.00 24 3.81 16.0 313 122 41.0 1.00 25 3.72 15.6 304 118 59 45.0 1.00 21 3.81 16.0 313 122 43.7 1.00 23 3.78 15.9 310 121 40.3 0.97 24 3.69 15.5 301 117 46.6 1.00 22 3.93 16.5 340 131 45.3 1.00 24 3.89 16.3 337 130 41.8 0.98 25 3.80 15.9 327 126 48.8 0.96 22 4.05 17.0 359 143 47.4 0.92 23 4.02 16.8 356 141 43.8 0.88 24 3.92 16.4 345 137 52.1 0.78 19 4.18 17.5 375 152 50.6 0.74 20 4.15 17.4 371 151 46.7 0.72 20 4.05 17.0 360 146 44.6 1.00 21 4.04 17.1 360 129 43.3 1.00 23 4.01 17.0 357 128 40.0 1.00 24 3.91 16.6 346 124 45.5 1.00 22 4.13 17.5 388 137 44.2 1.00 24 4.10 17.3 384 136 40.8 1.00 25 3.99 16.9 372 132 47.7 0.99 23 4.26 18.0 409 150 46.3 0.95 23 4.23 17.9 405 149 42.7 0.91 24 4.12 17.4 393 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.0 49.1 52.5 43.9 44.8 47.9 1.00 0.80 0.60 1.00 1.00 0.83 22 19 15 21 21 19 3.89 4.02 4.15 4.01 4.10 4.23 16.3 16.8 17.4 17.0 17.3 17.9 337 356 371 357 384 405 130 141 151 128 136 149 44.6 47.7 51.0 42.6 43.5 46.5 0.94 0.77 0.57 1.00 0.97 0.79 22 20 16 23 23 20 3.86 3.99 4.12 3.98 4.06 4.19 16.2 16.7 17.2 16.8 17.2 17.7 334 352 367 353 380 401 128 140 149 127 135 147 41.2 44.0 47.0 39.3 40.2 42.9 0.91 0.74 0.55 1.00 0.94 0.76 23 20 16 24 23 20 3.77 3.89 4.01 3.88 3.96 4.09 15.8 16.3 16.8 16.4 16.8 17.3 324 342 356 343 369 389 124 136 145 123 131 143 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 50.8 0.81 19 4.40 18.6 427 160 49.4 0.77 20 4.37 18.5 423 158 45.6 0.74 21 4.26 18.0 410 153 71 51.2 0.62 15 4.37 18.5 423 158 49.7 0.59 16 4.33 18.3 419 157 45.9 0.57 16 4.22 17.9 406 152 43.2 1.00 21 4.30 18.5 436 144 42.0 1.00 22 4.27 18.3 432 143 38.7 1.00 24 4.16 17.9 419 138 63 42.6 1.00 20 4.27 18.3 432 143 41.3 1.00 22 4.23 18.2 428 141 38.2 0.97 23 4.13 17.7 415 137 45.3 1.00 22 4.44 19.1 461 157 44.0 0.98 23 4.40 18.9 456 156 40.6 0.95 23 4.30 18.4 442 151 67 45.5 0.86 19 4.40 18.9 456 156 44.2 0.82 19 4.37 18.7 451 154 40.8 0.79 20 4.26 18.3 438 149 48.3 0.84 19 4.59 19.7 480 167 46.9 0.80 20 4.55 19.6 476 166 43.3 0.77 20 4.44 19.1 461 161 71 48.6 0.64 15 4.55 19.6 476 166 47.2 0.61 16 4.51 19.4 471 164 43.6 0.59 16 4.40 18.9 457 159 39.3 1.00 19 4.35 19.1 448 140 38.1 1.00 20 4.32 18.9 443 139 35.2 1.00 21 4.21 18.4 430 134 59 38.6 1.00 18 4.32 18.9 443 139 37.5 1.00 20 4.28 18.8 439 137 34.6 1.05 22 4.18 18.3 426 133 40.0 1.00 19 4.45 19.5 482 149 38.9 1.00 21 4.41 19.3 477 147 35.9 1.00 22 4.30 18.8 463 143 63 39.5 1.00 19 4.41 19.3 477 147 38.3 1.00 20 4.38 19.2 472 146 35.4 0.98 21 4.27 18.7 458 142 41.9 1.00 20 4.60 20.1 509 163 40.7 0.99 22 4.56 19.9 504 161 37.6 0.96 22 4.44 19.4 489 156 44.7 0.84 18 4.75 20.8 531 173 43.4 0.80 19 4.71 20.6 525 171 40.1 0.78 19 4.59 20.1 510 166 67 71 42.1 45.1 0.87 0.65 17 14 4.56 4.71 19.9 20.6 504 525 161 171 40.9 43.7 0.83 0.62 18 14 4.52 4.67 19.8 20.4 499 520 159 170 37.8 40.4 0.80 0.60 18 15 4.41 4.55 19.3 19.9 484 505 155 165 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 42.4 1.00 20 4.21 18.1 405 135 41.2 1.00 22 4.17 17.9 401 134 38.0 1.00 23 4.07 17.5 389 130 59 41.7 1.00 20 4.17 17.9 401 134 40.5 1.00 22 4.14 17.8 397 133 37.3 1.04 24 4.04 17.4 385 129 105ºF Product Specifications Expanded Cooling Data — GPH1348M41A* (cont.) 13 14 www.amana-hac.com 23.9 0.88 21 1.71 7.4 233 114 23.2 0.84 22 1.70 7.4 231 113 21.4 0.81 22 1.66 7.2 224 109 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr 723 825 927 59 23.5 0.77 18 1.69 7.4 231 113 22.8 0.74 19 1.68 7.3 229 111 21.1 0.71 19 1.64 7.1 222 108 Airflow MBh S/T ∆T kW 927 Amps Hi Pr Lo Pr MBh S/T ∆T kW 825 Amps Hi Pr Lo Pr MBh S/T ∆T 723 kW Amps Hi Pr Lo Pr 24.6 0.78 19 1.74 7.6 251 121 23.9 0.75 20 1.73 7.5 249 120 22.1 0.72 20 1.69 7.3 241 116 63 24.4 0.64 16 1.73 7.5 249 120 23.7 0.61 16 1.72 7.4 246 119 21.8 0.59 16 1.68 7.3 239 115 26.7 0.59 16 1.79 7.7 265 132 25.9 0.57 16 1.78 7.7 263 131 23.9 0.55 17 1.74 7.5 255 127 67 26.7 0.45 12 1.78 7.7 263 131 25.9 0.43 12 1.77 7.6 260 129 23.9 0.41 12 1.73 7.5 252 126 28.6 0.38 11 1.85 8.0 277 141 27.8 0.36 11 1.83 7.9 274 139 25.6 0.35 11 1.79 7.7 266 135 71 23.4 0.91 21 1.83 7.9 262 120 22.7 0.87 22 1.82 7.8 259 119 20.9 0.84 22 1.78 7.7 252 115 59 23.0 0.80 18 1.82 7.8 259 119 22.3 0.76 19 1.80 7.8 257 118 20.6 0.73 19 1.76 7.6 249 114 24.1 0.81 19 1.87 8.0 282 128 23.4 0.77 20 1.85 8.0 279 127 21.6 0.75 20 1.81 7.8 271 123 63 23.8 0.67 16 1.85 8.0 279 127 23.1 0.64 16 1.84 7.9 276 125 21.3 0.61 17 1.80 7.7 268 122 26.0 0.61 16 1.93 8.3 298 140 25.3 0.59 17 1.91 8.2 295 138 23.3 0.57 17 1.87 8.0 286 134 67 26.1 0.46 12 1.91 8.2 295 138 25.3 0.44 12 1.90 8.1 292 137 23.4 0.43 13 1.85 8.0 283 133 75ºF 27.9 0.40 11 1.99 8.5 310 149 27.1 0.38 11 1.97 8.4 307 147 25.0 0.36 12 1.92 8.3 298 143 71 22.8 0.93 21 1.94 8.4 298 125 22.1 0.89 22 1.93 8.4 295 124 20.4 0.86 22 1.88 8.2 286 120 59 22.4 0.82 18 1.93 8.4 295 124 21.8 0.78 19 1.91 8.3 292 122 20.1 0.75 19 1.87 8.1 283 119 23.5 0.83 19 1.98 8.6 321 133 22.8 0.79 20 1.97 8.5 317 132 21.0 0.77 21 1.92 8.4 308 128 25.4 0.63 16 2.04 8.8 338 145 24.7 0.60 17 2.03 8.8 335 144 22.8 0.58 17 1.98 8.6 325 139 27.3 0.41 11 2.11 9.1 353 154 26.5 0.39 11 2.09 9.1 350 153 24.4 0.37 12 2.04 8.8 339 148 22.2 0.96 21 2.04 8.9 339 131 21.6 0.92 22 2.02 8.8 336 130 19.9 0.88 22 1.97 8.6 326 126 22.9 0.86 20 2.08 9.1 365 140 22.2 0.82 20 2.06 9.0 361 138 20.5 0.79 21 2.01 8.8 351 134 24.8 0.65 16 2.14 9.4 386 152 24.1 0.62 17 2.13 9.3 382 151 22.2 0.60 17 2.08 9.1 370 146 26.6 0.42 11 2.21 9.7 402 162 25.8 0.40 11 2.20 9.6 398 161 23.8 0.39 12 2.14 9.4 386 156 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 71 23.2 25.5 21.9 22.7 24.8 0.68 0.47 0.85 0.71 0.49 16 12 18 16 12 1.97 2.03 2.02 2.06 2.13 8.5 8.8 8.8 9.0 9.3 317 335 336 361 382 132 144 130 138 151 22.6 24.7 21.2 22.0 24.1 0.65 0.45 0.81 0.67 0.47 16 12 19 17 13 1.95 2.01 2.00 2.05 2.11 8.5 8.7 8.8 9.0 9.2 314 332 333 358 378 130 142 129 137 149 20.8 22.8 19.6 20.3 22.3 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 1.90 1.96 1.96 2.00 2.06 8.3 8.5 8.6 8.8 9.0 305 322 323 347 367 126 138 125 133 145 - IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65ºF 21.8 0.89 19 2.16 9.6 411 146 21.1 0.85 20 2.15 9.5 407 145 19.5 0.82 20 2.10 9.3 394 140 63 21.5 0.73 16 2.15 9.5 407 145 20.9 0.70 16 2.13 9.4 403 143 19.3 0.67 17 2.08 9.2 390 139 23.6 0.68 16 2.23 9.9 434 160 22.9 0.64 16 2.21 9.8 429 158 21.1 0.62 17 2.16 9.6 417 153 67 23.6 0.51 12 2.21 9.8 429 158 22.9 0.48 12 2.20 9.7 425 157 21.1 0.47 13 2.14 9.5 412 152 25.3 0.43 11 2.30 10.2 452 170 24.5 0.41 11 2.29 10.1 448 168 22.7 0.40 12 2.23 9.9 434 163 71 19.6 1.00 19 2.19 9.9 422 142 19.0 0.96 20 2.17 9.8 418 141 17.5 0.93 21 2.12 9.6 405 137 59 19.3 0.89 17 2.17 9.8 417 141 18.7 0.84 18 2.15 9.7 413 139 17.3 0.81 18 2.10 9.5 401 135 20.2 0.90 18 2.24 10.1 454 151 19.6 0.86 19 2.22 10.0 449 150 18.1 0.83 19 2.16 9.8 436 145 63 20.0 0.74 15 2.22 10.0 449 150 19.4 0.71 15 2.20 9.9 445 148 17.9 0.68 15 2.15 9.7 431 144 21.8 0.68 15 2.31 10.4 479 165 21.2 0.65 15 2.29 10.3 474 164 19.6 0.63 16 2.23 10.0 460 159 67 21.9 0.51 11 2.29 10.3 474 164 21.2 0.49 12 2.27 10.2 470 162 19.6 0.47 12 2.22 10.0 456 157 115ºF 23.4 0.44 10 2.38 10.7 500 176 22.7 0.42 11 2.36 10.6 495 174 21.0 0.40 11 2.31 10.4 480 169 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 21.1 1.00 21 2.12 9.4 382 138 20.5 0.95 22 2.10 9.3 378 136 18.9 0.92 22 2.05 9.1 367 132 59 20.8 0.88 18 2.10 9.3 378 136 20.2 0.84 19 2.09 9.2 374 135 18.6 0.81 19 2.04 9.0 363 131 105ºF Product Specifications Expanded Cooling Data — GPH1360M41A* SS-DGPH13M SS-DGPH13M www.amana-hac.com 1577 1800 2023 MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr MBh S/T ∆T kW Amps Hi Pr Lo Pr Airflow MBh S/T ∆T kW 2023 Amps Hi Pr Lo Pr MBh S/T ∆T kW 1800 Amps Hi Pr Lo Pr MBh S/T ∆T 1577 kW Amps Hi Pr Lo Pr 63 58.0 0.86 23 4.19 17.6 265 115 56.3 0.82 24 4.15 17.5 262 113 52.0 0.79 24 4.06 17.1 255 110 57.8 58.9 0.96 0.92 25 25 4.13 4.22 17.4 17.8 249 268 109 116 56.1 57.2 0.91 0.88 26 26 4.10 4.19 17.3 17.6 246 265 108 115 51.8 52.8 0.88 0.85 27 26 4.01 4.09 16.9 17.2 239 257 105 111 59 56.8 0.91 24 4.10 17.3 246 108 55.1 0.87 25 4.07 17.1 244 107 50.9 0.84 25 3.98 16.7 236 103 61.7 0.83 23 4.35 18.3 283 126 59.9 0.79 24 4.31 18.1 280 125 55.3 0.77 25 4.21 17.7 271 121 67 62.0 0.70 20 4.31 18.1 280 125 60.2 0.66 20 4.28 18.0 277 124 55.6 0.64 21 4.18 17.6 269 120 65.8 0.68 20 4.48 18.9 295 135 63.9 0.64 21 4.45 18.7 292 133 59.0 0.62 21 4.34 18.3 283 129 71 66.3 0.52 16 4.45 18.7 292 133 64.4 0.50 16 4.41 18.6 289 132 59.4 0.48 17 4.31 18.1 280 128 56.4 0.99 25 4.44 18.6 279 115 54.8 0.95 26 4.41 18.5 276 114 50.6 0.91 27 4.30 18.0 268 110 59 55.5 0.95 24 4.41 18.5 276 114 53.9 0.90 25 4.37 18.3 274 113 49.7 0.87 25 4.27 17.9 265 109 57.5 0.96 25 4.53 19.0 300 122 55.9 0.91 26 4.50 18.9 297 121 51.6 0.88 26 4.39 18.4 288 117 63 56.7 0.89 23 4.50 18.9 297 121 55.0 0.85 24 4.46 18.7 294 120 50.8 0.82 24 4.36 18.3 286 116 60.3 0.86 24 4.67 19.6 317 134 58.5 0.82 25 4.64 19.4 314 132 54.0 0.79 25 4.53 19.0 305 128 67 60.6 0.72 20 4.64 19.4 314 132 58.8 0.69 21 4.60 19.3 311 131 54.3 0.66 21 4.49 18.8 302 127 75ºF 64.3 0.70 20 4.82 20.2 331 142 62.4 0.67 21 4.78 20.1 327 141 57.6 0.64 22 4.67 19.6 318 137 71 64.7 0.54 16 4.78 20.1 327 141 62.9 0.51 17 4.75 19.9 324 139 58.0 0.50 17 4.63 19.4 315 135 55.1 56.2 1.00 0.98 25 25 4.71 4.81 20.1 20.5 317 342 119 127 53.5 54.5 0.97 0.94 27 26 4.67 4.77 19.9 20.3 314 338 118 126 49.4 50.3 0.94 0.90 27 26 4.56 4.66 19.4 19.8 305 328 115 122 59 54.2 0.97 24 4.67 19.9 314 118 52.6 0.93 25 4.64 19.7 311 117 48.5 0.89 25 4.53 19.3 302 114 58.8 0.89 24 4.96 21.1 361 139 57.1 0.84 25 4.92 20.9 357 137 52.7 0.81 25 4.81 20.4 346 133 62.8 0.72 20 5.12 21.8 376 148 60.9 0.69 21 5.08 21.6 372 146 56.2 0.66 22 4.96 21.1 361 142 53.8 1.00 24 4.95 21.3 361 126 52.2 1.00 27 4.91 21.1 358 124 48.2 0.97 27 4.79 20.6 347 121 54.8 1.00 25 5.06 21.8 389 134 53.2 0.97 26 5.02 21.6 385 132 49.1 0.93 27 4.89 21.0 374 128 57.4 0.91 24 5.22 22.4 411 146 55.7 0.87 25 5.18 22.2 407 144 51.4 0.84 25 5.05 21.7 395 140 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.3 59.1 63.2 52.8 54.0 57.7 0.91 0.74 0.55 1.00 0.94 0.76 23 20 16 24 23 20 4.77 4.92 5.08 4.91 5.02 5.18 20.3 20.9 21.6 21.1 21.6 22.2 338 357 372 358 385 407 126 137 146 124 132 144 53.7 57.4 61.4 51.3 52.4 56.0 0.87 0.71 0.53 0.96 0.90 0.73 24 21 17 25 24 21 4.74 4.88 5.04 4.87 4.98 5.14 20.2 20.8 21.5 20.9 21.4 22.0 335 354 369 354 381 403 125 136 145 123 131 143 49.6 53.0 56.6 47.3 48.4 51.7 0.84 0.68 0.51 0.92 0.86 0.70 24 21 17 25 24 21 4.62 4.77 4.92 4.75 4.86 5.01 19.7 20.2 20.9 20.4 20.9 21.5 325 343 358 344 370 391 121 132 141 119 127 139 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65ºF 61.2 0.74 21 5.39 23.2 428 155 59.4 0.71 21 5.35 23.0 424 154 54.9 0.68 22 5.21 22.4 411 149 71 61.7 0.57 16 5.35 23.0 424 154 59.9 0.54 17 5.30 22.8 420 152 55.3 0.53 17 5.17 22.2 407 148 52.1 1.00 24 5.27 23.0 438 140 50.5 1.00 26 5.22 22.8 433 139 46.7 0.97 26 5.10 22.3 420 134 63 51.3 1.00 23 5.22 22.8 433 139 49.8 0.93 24 5.18 22.6 429 137 46.0 0.90 24 5.05 22.1 416 133 54.5 0.95 24 5.44 23.7 462 153 52.9 0.90 24 5.39 23.5 458 151 48.9 0.87 25 5.26 22.9 444 147 67 54.8 0.79 20 5.39 23.5 458 151 53.2 0.76 21 5.35 23.3 453 150 49.1 0.73 21 5.22 22.7 439 145 58.2 0.77 20 5.61 24.5 482 163 56.5 0.73 21 5.57 24.3 477 161 52.1 0.71 22 5.43 23.7 463 156 71 58.6 0.59 16 5.57 24.3 477 161 56.9 0.57 16 5.52 24.1 473 159 52.5 0.55 17 5.39 23.5 458 155 47.3 1.00 21 5.33 23.7 449 136 45.9 1.00 23 5.29 23.5 445 135 42.4 1.00 25 5.16 22.9 432 131 59 46.5 1.00 21 5.29 23.5 445 135 45.1 1.00 23 5.24 23.3 440 133 41.7 0.96 23 5.12 22.8 427 129 48.2 1.00 22 5.45 24.3 484 145 46.8 1.00 24 5.40 24.1 479 143 43.2 0.98 25 5.27 23.5 464 139 63 47.5 1.00 22 5.40 24.1 479 143 46.1 0.94 22 5.36 23.9 474 142 42.6 0.90 22 5.23 23.3 460 138 71 54.3 0.60 15 5.76 25.7 527 167 52.7 0.57 15 5.71 25.5 522 165 48.6 0.55 16 5.57 24.8 506 160 50.5 53.9 0.96 0.78 22 19 5.62 5.81 25.0 25.9 511 533 158 168 49.0 52.3 0.91 0.74 23 20 5.58 5.76 24.8 25.7 506 527 156 167 45.3 48.3 0.88 0.71 23 20 5.44 5.62 24.2 25.0 490 511 152 162 67 50.8 0.80 18 5.58 24.8 506 156 49.3 0.76 19 5.53 24.6 501 155 45.5 0.74 20 5.39 24.0 486 150 115ºF kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 51.1 1.00 23 5.15 22.5 407 132 49.6 1.00 25 5.11 22.3 403 130 45.8 1.00 27 4.99 21.8 391 126 59 50.2 1.00 23 5.11 22.3 403 130 48.7 0.99 25 5.07 22.2 399 129 45.0 0.96 25 4.95 21.6 387 125 105ºF Product Specifications Expanded Cooling Data — GPH1360M41A* (cont.) 15 Product Specifications Expanded Heating Data GPH1324M41* Outdoor Ambient Temperature 65 60 55 50 47 MBh 28.9 27.4 T/R 32.4 30.7 kW 2.14 Amps 10.4 45 40 25.8 24.1 23.0 22.3 20.7 28.9 27.0 25.8 25.0 23.2 2.10 2.06 2.01 1.99 1.97 1.94 9.8 9.2 8.8 8.5 8.4 8.0 35 30 25 20 17 15 19.1 16.7 21.4 18.8 1.89 7.7 10 5 15.4 14.2 13.4 17.3 15.9 15.1 2.32 2.26 2.21 7.4 7.1 6.9 0 -5 12.9 11.6 14.5 13.0 2.18 2.16 6.7 6.7 -10 10.3 9.0 7.6 6.3 11.5 10.1 8.6 7.0 2.10 2.05 2.00 1.95 1.89 6.4 6.1 5.8 5.5 5.1 COP 3.96 3.82 3.67 3.50 3.38 3.30 3.13 2.95 2.11 1.99 1.88 1.80 1.75 1.61 1.47 1.31 1.15 0.97 EER 13.5 13.1 12.5 12.0 11.5 11.3 10.7 10.1 7.2 6.8 6.4 6.2 6.0 5.5 5.0 4.5 3.9 3.3 Hi Pr 379 364 350 334 326 320 308 295 283 270 260 253 249 239 230 221 213 205 Lo Pr 135 126 118 108 102 98 90 80 73 65 57 53 51 43 37 31 27 22 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. Amps: Unit amps (comp.+ evap motor + condenser fan motor) kW = Total system power GPH1330M41* Outdoor Ambient Temperature 65 60 MBh 36.2 34.3 T/R 31.9 30.2 kW 2.74 2.68 Amps 13.6 12.7 55 50 47 45 40 35 30 25 20 17 15 32.3 30.2 28.8 27.9 25.9 28.4 26.6 25.4 24.6 22.9 2.63 2.58 2.55 2.53 12.0 11.4 11.1 10.9 10 5 23.9 21.2 19.6 18.0 17.0 21.1 18.7 17.3 15.9 15.0 2.48 2.43 2.29 2.24 2.19 10.4 9.9 9.6 9.2 8.9 0 -5 -10 16.4 14.7 13.0 11.4 9.7 7.9 14.4 13.0 11.5 10.0 8.6 7.0 2.17 2.15 2.10 2.05 2.00 1.95 1.90 8.7 8.6 8.2 7.8 7.5 7.0 6.5 COP 3.87 3.74 3.59 3.42 3.30 3.23 3.06 2.88 2.71 2.55 2.40 2.30 2.23 2.05 1.86 1.66 1.46 1.22 EER 13.2 12.8 12.3 11.7 11.3 11.0 10.5 9.8 9.2 8.7 8.2 7.9 7.6 7.0 6.4 5.7 5.0 4.2 Hi Pr 375 359 346 330 323 316 304 292 280 267 256 250 246 236 227 218 210 203 Lo Pr 131 122 114 105 99 95 88 78 70 63 55 51 49 42 36 30 27 21 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. Amps: Unit amps (comp.+ evap motor + condenser fan motor) kW = Total system power GPH1336M41* Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 43.0 40.7 38.3 35.8 34.2 33.1 30.8 28.4 24.4 22.6 20.8 19.6 18.9 17.0 15.0 13.1 11.2 9.2 T/R 34.6 32.8 30.8 28.8 27.5 26.7 24.8 22.9 19.7 18.2 16.7 15.8 15.2 13.6 12.1 10.6 9.0 7.4 kW 3.10 3.04 2.98 2.92 2.89 2.86 2.81 2.75 2.36 2.31 2.26 2.24 2.22 2.17 2.12 2.07 2.02 1.97 Amps 15.4 14.4 13.6 12.9 12.5 12.3 11.7 11.1 10.7 10.3 9.9 9.7 9.6 9.2 8.7 8.3 7.8 7.2 COP 4.06 3.92 3.76 3.58 3.46 3.39 3.21 3.02 3.03 2.86 2.69 2.57 2.50 2.29 2.08 1.85 1.62 1.36 EER 13.9 13.4 12.8 12.2 11.8 11.6 11.0 10.3 10.4 9.8 9.2 8.8 8.5 7.8 7.1 6.3 5.5 4.6 Hi Pr 403 386 371 355 347 340 327 314 300 287 276 269 264 254 244 234 226 218 Lo Pr 137 127 119 109 103 99 91 81 73 66 58 54 52 44 38 32 28 22 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. 16 www.amana-hac.com Amps: Unit amps (comp.+ evap motor + condenser fan motor) kW = Total system power SS-DGPH13M Product Specifications Expanded Heating Data (cont.) GPH1342M41* Outdoor Ambient Temperature 65 60 55 50 47 MBh 50.3 47.6 T/R 35.8 33.9 45 40 44.8 41.9 31.9 29.8 40.0 38.8 36.0 28.5 27.6 25.6 35 30 25 20 17 15 33.2 27.5 25.4 23.6 19.6 18.1 23.4 22.1 21.3 16.7 15.7 15.1 10 5 0 -5 -10 19.1 16.9 14.8 12.6 10.3 13.6 12.0 10.5 9.0 7.3 kW 3.58 3.52 3.45 3.38 3.34 3.31 3.25 3.18 2.31 2.27 2.23 2.20 2.18 2.14 2.09 2.05 2.01 1.96 Amps 17.6 16.5 15.6 14.8 14.3 14.1 13.4 12.8 12.3 11.9 11.4 11.2 11.1 10.6 10.0 9.6 9.0 8.3 COP 4.11 3.96 3.80 3.62 3.50 3.42 3.24 3.05 3.48 3.27 3.07 2.94 2.85 2.61 2.36 2.11 1.84 1.54 EER 14.0 13.5 13.0 12.4 12.0 11.7 11.1 10.4 11.9 11.2 10.5 10.0 9.7 8.9 8.1 7.2 6.3 5.3 Hi Pr 323 310 298 285 278 273 262 252 241 230 221 216 212 204 196 188 181 175 Lo Pr 141 131 122 112 106 102 94 84 75 67 59 55 53 45 39 33 29 22 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. Amps: Unit amps (comp.+ evap motor + condenser fan motor) High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. kW = Total system power GPH1348M41* Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 57.2 54.1 51.0 47.6 45.5 44.1 41.0 37.8 32.8 30.2 27.8 26.3 25.3 22.7 20.1 17.6 15.0 12.3 T/R 30.8 29.1 27.4 25.6 24.5 23.7 22.0 20.3 17.6 16.3 15.0 14.2 13.6 12.2 10.8 9.5 8.1 6.6 kW 3.90 3.83 3.75 3.68 3.63 3.60 3.53 3.46 2.48 2.43 2.38 2.36 2.34 2.29 2.24 2.19 2.14 2.09 Amps 19.0 17.7 16.7 15.8 15.3 15.0 14.3 13.7 13.1 12.6 12.1 11.9 11.8 11.2 10.6 10.1 9.5 8.7 COP 4.29 4.14 3.97 3.79 3.66 3.58 3.39 3.20 3.86 3.64 3.42 3.27 3.17 2.91 2.63 2.35 2.05 1.72 EER 14.7 14.1 13.6 13.0 12.5 12.2 11.6 10.9 13.2 12.4 11.7 11.2 10.8 9.9 9.0 8.0 7.0 5.9 Hi Pr 372 357 343 328 320 314 302 290 278 265 255 249 244 235 226 217 209 202 Lo Pr 130 121 113 104 98 95 87 77 70 62 55 51 49 42 36 30 26 21 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. Amps: Unit amps (comp.+ evap motor + condenser fan motor) High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. kW = Total system power GPH1360M41* Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 69.8 66.0 62.2 58.1 55.5 53.8 50.0 46.1 39.1 36.1 33.3 31.4 30.3 27.1 24.1 21.0 17.9 14.7 T/R 35.9 34.0 32.0 29.9 28.5 27.7 25.7 23.7 20.1 18.6 17.1 16.2 15.6 14.0 12.4 10.8 9.2 7.5 kW 4.80 4.71 4.62 4.53 4.47 4.44 4.35 4.26 2.41 2.36 2.32 2.30 2.28 2.24 2.20 2.16 2.12 2.08 MBh Amps 24.1 22.5 21.2 20.1 19.4 19.1 18.1 17.3 16.7 16.0 15.4 15.0 14.9 14.2 13.4 12.8 12.0 11.0 COP 4.25 4.10 3.94 3.76 3.63 3.55 3.36 3.17 4.76 4.47 4.19 4.00 3.88 3.54 3.20 2.84 2.47 2.06 EER 14.5 14.0 13.5 12.8 12.4 12.1 11.5 10.8 16.3 15.3 14.3 13.7 13.2 12.1 10.9 9.7 8.4 7.1 Hi Pr 385 369 354 339 331 325 312 300 287 274 263 257 252 243 233 224 216 208 Lo Pr 134 124 116 107 101 97 89 80 72 64 56 52 50 43 37 31 27 21 Above information is for nominal CFM and 70° indoor dry bulb; instantaneous capacity listed. Amps: Unit amps (comp.+ evap motor + condenser fan motor) High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting. kW = Total system power SS-DGPH13M www.amana-hac.com 17 18 16 www.amana-hac.com 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 Product Specifications Temperature Rise RPERFORMANCE ange Chart BLOWER DATA SS-DGPH13M TEMPERATURE RISE Product Specifications Airflow Data Model Motor Tap Speed GPH13 24M41* Low 230 Med 230 High 230 Low GPH13 30M41* GPH13 36M41* GPH13 42M41* GPH13 48M41* GPH13 60M41* Volts 230 Med 230 High 230 Low 230 Med 230 High 230 Low 230 Med 230 High 230 T1 (G) 230 T2 / T3 (W2) 230 T4 / T5 (Y) 230 T1 (G) 230 T2 / T3 (W2) 230 T4 / T5 (Y) 230 E.S.P (In. of H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM 667 596 -------- -------- -------- -------- -------- -------- Watts 153 150 -------- -------- -------- -------- -------- -------- CFM 897 841 784 713 610 -------- -------- -------- Watts 233 229 224 217 207 -------- -------- -------- CFM 1242 1181 1122 1057 982 883 719 617 Watts 373 364 354 344 333 318 298 284 CFM 1097 1059 1016 959 901 818 648 562 Watts 337 330 324 315 305 290 271 257 CFM 1253 1204 1148 1097 1033 952 777 670 Watts 397 388 379 369 356 342 313 297 CFM 1448 1380 1323 1258 1194 1106 1008 864 Watts 499 483 472 459 446 427 410 382 CFM 1122 1078 1032 972 915 804 687 558 Watts 338 330 321 310 300 283 264 250 CFM 1387 1331 1264 1209 1119 1041 935 748 Watts 456 440 428 412 399 382 363 330 CFM 1521 1454 1388 1311 1230 1144 1055 939 Watts 534 521 510 490 477 461 442 420 CFM 1122 1078 1032 972 915 804 687 558 Watts 338 330 321 310 300 283 264 250 CFM 1387 1331 1264 1209 1119 1041 935 748 Watts 456 440 428 412 399 382 363 330 CFM 1521 1454 1388 1311 1230 1144 1055 939 Watts 534 521 510 490 477 461 442 420 CFM 1,440 1,395 1,360 1,310 1,265 1,235 1,190 1,130 Watts 275 285 295 315 325 335 345 355 CFM 1,795 1,765 1,715 1,695 1,650 1,600 1,500 1,375 Watts 475 490 505 520 530 535 510 475 CFM 1,860 1,820 1,785 1,745 1,700 1,625 1,515 1,395 Watts 515 530 545 565 570 550 535 485 CFM 1,755 1,720 1,685 1,645 1,615 1,570 1,530 1,465 Watts 420 435 455 460 475 490 500 500 CFM 1,850 1,820 1,775 1,735 1,705 1,675 1,610 1,495 Watts 480 500 515 525 535 555 545 520 CFM 2,180 2,125 2,050 1,975 1,875 1,800 1,655 1,530 Watts 770 755 725 700 675 640 575 540 Notes: • Data shown is dry coil. Wet coil pressure drop is approximately 0.1” H2O, for two-row indoor coil; 0.2” H2O, for three-row indoor coil; and 0.3” H2O, for four-row indoor coil. • Data shown does not include filter pressure drop, approximately 0.08” H2O. • ALL MODELS SHOULD RUN NO LESS THAN 350 CFM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair Parts list. • Reduce airflow by 2% for 208-volt operation. SS-DGPH13M www.amana-hac.com 19 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) Heat Kit Match-Ups Circuit #1 MCA¹ Circuit #2 MOP² MCA¹ Actual kW / BTU@ 240V MOP² GPH1324M41** 1.5 / 1.5 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400 GPH1330M41** 1.5 / 1.5 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400 HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600 GPH1336M41** 1.9 / 1.9 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400 HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600 GPH1342M41** 1.9 / 1.9 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 45 / 52 60 / 60 -- -- 9.5 / 32,400 HKR-15*, HKR-15C* 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600 GPH1348M41** 5.8 / 5.8 -- -- -- -- HKR-05*, HKR-05C* 25 / 28 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 38 / 40 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 49 / 56 60 / 60 -- -- 9.5 / 32,400 HKR-15*, HKR-15C* 49 / 56 60 / 60 22 / 25 30 / 30 14.25 / 48,600 HKR-20*, HKR-20C* 49 / 56 60 / 60 43 / 49 60 / 60 19.5 / 66,500 GPH1360M41** 7.6 / 7.6 -- -- -- -- HKR-05*, HKR-05C* 29 / 30 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C* 39 / 40 40 / 40 -- -- 7.0 / 23,800 HKR-10*, HKR-10C* 51 / 58 60 / 60 -- -- 9.5 / 32,400 HKR-15*, HKR-15C* 51 / 58 60 / 60 22 / 25 30 / 30 14.25 / 48,600 HKR-20*, HKR-20C* 51 / 58 60 / 60 43 / 49 60 / 60 19.5 / 66,500 ¹ Minimum Circuit Ampacity @ 208 / 240 V * Revision level that may or may not be designated 20 ² Maximum Overcurrent Protection device @ 208 / 240 V C Circuit Breaker option www.amana-hac.com SS-DGPH13M Product Specifications Dimensions    H          B             Model Med. Large W” D” H” B H GPH1324M41 X 47 51 34¾ 16” 32½” GPH1330M41 X 47 51 34¾ 16” 32½” GPH1336M41 X 47 51 34¾ 16” 32½” GPH1342M41 X 47 51 34¾ 16” 32½” GPH1348M41 X 47 51 42¾ 18” 40” GPH1360M41 X 47 51 42¾ 18” 40” SS-DGPH13M www.amana-hac.com 21 Product Specifications Wiring Diagram — GPH1324-42M41A* LPS SEE NOTE # 8 SEE NOTE # 7 YL/PK PU BK YL/PK PU SEE NOTE 4 BK RD BK BK T1 L1 PU PU RD RD GND C C R R C OR BK BK 0-RV DC LVJB PU WH C-RV W WH PLF 6 9 F 2 5 8 RCCF 1 4 7 3 Y YL H R-PS1 R-DFT DFT DF2 DF1 PS2 C  SA RD BR ++ BK PU RD RD BK BL RD BK (COM) BK BR BK GR S C R 2 SPEED OPTIONAL L1 COMP SEE NOTE # 3 T2 C COMP C S 2 POLE ONLY SEE NOTE 7 DF2 HVDR RCCF H S.A. CM BR P 3 L F 1 M2 1 3 2 4 NO SEE NOTE 2 M1 C DF1 F SEE NOTE 5 EBTDR COMPONENT LEGEN D BR C CCR CH CHS CM COMP DC DFT EBTDR EM FC GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF R T1 EBTDR NC COM EM FC SA TR 208-240 SEE NOTE 4 BK BK L2 CH C CHS FC SUPPLY VOLTAGE 208-240/1/60 SEE NOTE 3 CHS RD CM FC RVC RD EM BR CH BK YL BR HIGH BR DFT 3 SPEED SEE NOTE # 3 BK LOW PU EM T H E R M O S T A T CONTROL BOX PU RD (TRANS240V) PU (M1) RD BK Y R G W1 O W2 C BR BL SEE NOTE # 5 HPS YL RD GR WH OR BR BL BR Y HVDR PU BL/PK YL 0 LVDR RD BL/PK PU YL OR 0 PU BK RD PU CNT CCR ⚡ BK 4 BR 2 0 8 2 4 0 / 1 / 6 0 SEE NOTE #6 BLOWER INTERLO CK RELAY CONTACTOR COMPRESSOR CONTACTOR R ELAY CRANKCASE HEATER CRANKCASE HEATER SW ITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ELECTRONIC BLOWER TIME DELA Y RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH PRESSURE SW ITCH HIGH VOLTAGE D EFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFR OST RELAY LOW VOLTAGE JUNCTION BO X FEMALE PLUG / CO NNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BK BL BR GR OR PU RD WH YL WIRE CODE BLACK BLUE BROWN GREEN ORANGE PURPLE RED WHITE YELLOW 2 1 3 TR 24V EBTDR R NOTES: C G DFT RVC R C-RV O-RV R O W DFT R-DFT DC R-PS1 Y PS2 C CNT LPS 4 P L 5 F 1. REPLACEMENT WIRE MUST BE SA ME SIZE A ND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR "COM" WITH LEAD ON EBTDR "M1" OR "M2". 3. CRANKCASE HEATER AND CRANKCASE HEATER SW ITCH FACTOR Y EQUIPPED WHEN REQUIRED. 4. FOR 208 VOLT TRANSFORMER OPERATION MOV E PURPLE WIRES FROM TERMINAL 3 TERMINAL 2 ON TRANSFORMER. 5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 6. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLAS S 2 WIRE. 7. DOUBLE POLE CO NTACTOR S HOWN. SINGLE POLE C ONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERN ATE CONFIG URATION. 8. COMMON SIDE OF CONTACTOR C AN NOT BE G ROUNDED OR CONNECTED TO AN Y OTHER COMMON (24V). High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. PU BK L2 C 3 2 RD RD PU T2 Warning BL RD RD 1 BL COM K1 BL BL 24V NOTE #2 NC M1 M2   BL NO K1 PU 3 ⚠ YL BK EBTDR R XFMR-R XFMR-C C BL 2 208 240 TR C RD G YL Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. 1 GR C HPS SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION 6 R W2 O W1 Y G C THERMOSTAT 0140G01745-B 22 www.amana-hac.com SS-DGPH13M Product Specifications Wiring Diagram — GPH1348-60M41A* SEE NOTE 8 SEE NOTE 3 PU LPS PU 1 2 YL/PK PU BL BL BL RD BL Y C Y R-PS1 PU C RD C-RV YL BK O-RV LVDR BK R WH BL WH DFT H RD YL C F RCCF RD RD PU OR RD PLF 3 6 9 2 5 8 1 4 7 BR BL/PK RD RD ++ YL BK PU BR BK BL/PK YL BK RD SEE NOTE 6 PU CH EM BK BK CHS L1 GR CM HPS BK COMP RVC SEE NOTE 2 BK RD RD S C R DFT T H E R M O S T A T Y R G W1 O W2 C BK PU PU YL WH GR LVJB YL RD GR WH OR BR BL BR CONTROL BOX PU GR WH SA SEE NOTE 4 RD C L G N 1 2 3 4 5 RD BR RD R-DFT DF1 RD WH W HVDR DF2 GND GR PU RD O R GR PU PU OR PU CNT DC YL BL SEE NOTE 5 L1 T1 60 C PS2 CCR C BK BL PU GR 2 0 8 2 4 0 / 1 / L2 T2 RD BK BK YL BK BK 240 24V YL PU BL 3 208 TR C YL/PK SEE NOTE 7 BK BK SEE NOTE 6 L2 SUPPLY VOLTAGE 208-240/1/60 C T1 2 POLE ONLY SEE NOTE 7 T2 R C COMP C S H COMPONENT LEGEND C CCR CH CHS CM COMP DC DFT EM GND HVDR LPS LVDR LVJB PLF RVC RCCF C DF1 DF2 HVDR RCCF F CM S.A. SEE NOTE 4 SEE NOTE 6 CHS SEE NOTE 2 3 G 1 CH L EM N SA TR HPS 2 2 1 C-RV O-RV O W DFT DC Y DFT R-DFT R-PS1 PS2 C CNT LPS HPS 2 3 1 EM C 4 5 6 PLF W2 SEE NOTE 2 SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION O W1 Y G C THERMOSTAT Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ DR SS-DGPH13M ⚠ 208-240/1/60 0140G01640-A 6.00u.10 Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. WIRE CODE BLACK BLUE BROWN GREEN ORANGE PURPLE RED WHITE YELLOW 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V). C R BK BL BR GR OR PU RD WH YL NOTES: TR R FIELD WIRING HIGH VOLTAGE LOW VOLTAGE 3 24V RVC FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE 208-240 SEE NOTE 3 R CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT EVAPORATOR MOTOR EQUIPMENT GROUND HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER HIGH PRESSURE SWITCH www.amana-hac.com 23 Product Specifications Accessories Item Number Accessory Description Medium Chassis Large Chassis Concentric Kit CDK36 CDK4872 Downflow Economizer GPH13MED102 GPH13MED103 Downflow Internal Filter Rack GPH13MFR102 GPH13MFR103 Downflow Manual Damper PGMDD101/102 PGMDD103 Downflow Motorized Damper PGMDMD101/102 PGMDMD103 Downflow Square to Round SQRPG101/102 SQRPG103 External Horizontal Filter Rack GPGHFR101-103 GPGHFR101-103 Horizontal Duct Cover 20464501PDGK 20464502PDGK Horizontal Economizer PEHH101/102 PEHH103 Horizontal manual Damper PGMDH102 PGMDH103 Horizontal Motorized Damper PGMDMH102 PGMDMH103 Horizontal Square to Round SQRPGH101/102 SQRPGH103 Outdoor Thermostat & Emergency Heat Relay Kit OT/EHR18-60 OT/EHR18-60 Outdoor Thermostat Kit w/ Lockout Stat OT18-60A OT18-60A Roof Curb PGC101/102/103 PGC101/102/103 Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2012 • Goodman Company, L.P. • Houston, Texas • Printed in the USA. 24 www.amana-hac.com SS-DGPH13M