Preview only show first 10 pages with watermark. For full document please download

Amg 50-12

   EMBED


Share

Transcript

AMG series Sealed maintenance-free lead-acid battery AMG series batteries made in GEL technology are designed for standby use (emergency power supply) as well as hard condition cycle use like large number of cycles, deep discharge and high temperature. The cycle life of AMG series batteries reaches 600 cycles for 80% depth of discharge. One-way, self regulating pressure relief valves prevent the case from blowing up, by preventing excessive buildup of pressure in the cells. AMG 50-12 Main applications • emergency lighting systems • wind turbines • solar powered systems • cable TV • boats, yachts • traction • electric vehicles • wheelchairs, golf-carts • uninterruptible power supplies (UPS) • telecommunication PABX • power station Discharge characteristics graph Technical data Weight Dimensions Height Lenght Width Internal resistance o Charging voltage @ 25 C Standby use Cycle use Charging current Recommended Maximum Max. discharge current (for 5 sec) Container type Standard Fire retardant (optional) 13.0 o T: 25 C 12.0 Terminal voltage [V] Design life 12 V 50 Ah/ C20 o 8 years @ 25 C o 10-12 years @ 20 C according to Eurobat, High Performance group ~ 16.6 kg 11.0 0.2C 0.4C 10.0 0.1C 0.05C 0.6C 1C 2C 9.0 8.0 211 mm 229 mm 138 mm £ 9.0 mW 1 2 4 6 8 10 20 40 60 2 4 [min] 6 8 10 20 [h] discharge time Dimensions 13.65 V ± 0.15 V 14.70 V ± 0.30 V 5.0 A 12.5 A 500 A 211 205 Nominal voltage Nominal capacity ABS UL 94-HB ABS UL 94-V0 Terminals M6 38 138 Not restricted for air, surface and water transport. Classified as nonhazardous material (IATA/ICAO Special Provision A67, DOT-CFR Title 49 parts 171-189, IMDG amendment 27). 180 229 Tolerance: +/- 2mm; o Constant current discharge table (Current [A], 25 [ C]) F.V. [V/cell] 20 min 30 min 45 min 1h 2h 3h Discharge time 4h 5h 6h 7h 8h 9h 10h 20h 1,80 1,75 1,70 48,5 54,5 58,7 37,1 40,8 43,7 27,9 30,2 32,1 23,4 25,1 26,5 14,6 15,4 16,4 11,0 11,6 12,1 9,00 9,43 9,74 7,70 8,00 8,25 6,64 6,88 7,12 5,86 6,07 6,27 5,29 5,46 5,63 4,86 5,00 5,13 4,56 4,65 4,76 2,50 2,55 2,58 o Constant power discharge table (Power [W/cell], 25 [ C]) F.V. [V/cell] 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 7h 8h 9h 10h 20h 1,75 1,70 1,67 101,7 108,4 111,5 77,2 81,9 84,2 57,7 60,8 62,6 48,3 50,8 52,4 29,9 31,6 32,2 22,6 23,5 24,1 18,4 19,0 19,4 15,7 16,1 16,4 13,5 14,0 14,2 12,0 12,4 12,5 10,8 11,1 11,3 9,93 10,2 10,3 9,24 9,45 9,55 5,08 5,14 5,18 Discharge time F.V. - Final voltage Pb www.acumax.eu Change no: 0/2014.10