Preview only show first 10 pages with watermark. For full document please download

Amphenol Africa

   EMBED


Share

Transcript

Amphenol Telecom Solutions RG-8/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC 1 Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 5KV Direct Current Resistance – Inner Conductor 6.23 ȍ / Km Max – Outer Conductor 3.94 ȍ / Km Max – Loop 10.17 ȍ / Km Max Capacitance – 94 pF / m Velocity of Propagation – 66 % Reference RG-8/U Diameter Weight kg/km 10.3 ± 0.05 163 (less reel) Bend Radius: 114mm Frequency at (MHz) Attenuation ” (db / 100m) 10 1.97 50 4.30 100 6.20 200 9.20 400 13.80 700 19.40 900 22.60 1000 24.30 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Stranded bare Copper conductor. Nominal diameter: 7/0.724mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 7.24mm. 3 1st Shield: Bare Copper braid. Coverage: 97%. Outer braid diameter: 7.95mm. 4 Jacket: Black PVC jacket. Nominal diameter: 10.30mm. Numerical identification. RG-8/U/M 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Non-bonded APA Laminate Shield. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC 1 Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 5KV Direct Current Resistance – Inner Conductor 6.23 ȍ / Km Max – Outer Conductor 4.92 ȍ / Km Max – Loop 11.15 ȍ / Km Max Capacitance – 98 pF / m Velocity of Propagation – 66 % Reference Diameter Weight kg/km RG-8/U/M 10.15 ± 0.05 153 (less reel) Bend Radius: 50.75mm Frequency at (MHz) Attenuation ” (db / 100m) 1 0.52 10 1.80 50 4.30 100 6.20 200 9.20 400 13.80 700 19.40 900 22.60 1000 24.30 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Stranded bare Copper conductor. Nominal diameter: 7/0.724mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 7.20mm. 3 1st Shield: Non-bonded APA Laminate Shield. Coverage: 100%. Diameter: 7.30mm. 4 2nd Shield: Bare Copper braid. Coverage: 92%. Outer braid diameter: 8.00mm. 5 Jacket: Black PVC jacket. Nominal diameter: 10.15mm. Numerical identification. ATFC U-JIN / ATFCB D-12 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected] Amphenol Telecom Solutions RG-58C/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC RG-58C/U 1 Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 1.9KV Direct Current Resistance – Inner Conductor 49.00 ȍ / Km Max – Outer Conductor 13.4 ȍ / Km Max – Loop 62.4 ȍ / Km Max Capacitance – 97 pF / m Velocity of Propagation – 66 % Reference Diameter Weight kg/km 4.95 ± 0.05 38 (less reel) Bend Radius: 14.5mm Frequency at (MHz) 10 50 Attenuation ” (db / 100m) 4.60 10.80 100 300 400 700 900 1000 16.10 23.90 40.68 55.80 65.80 70.50 Cable Constitution No: Description: 1 Inner Conductor: Stranded tinned Copper conductor. Nominal diameter: 0.813mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 2.95mm. 3 1st Shield: Tinned Copper braid. Coverage: 92%. Outer braid diameter: 3.45mm. 4 Jacket: Black PVC jacket. Nominal diameter: 4.95mm. Numerical identification. RG-58/U LL 50 Ohm Low Loss Coaxial Cable Main Characteristics Weight & Dimension Characteristics Low Loss Coaxial cable used for switching and transmission network. Non-bonded AP Laminate Shield. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Reference Diameter Weight kg/km RG-58/U LL 4.95 ± 0.05 40 (less reel) 1 Bend Radius: 15mm Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 1.9KV Direct Current Resistance – Inner Conductor 32.80 ȍ / Km Max – Outer Conductor 13.40 ȍ / Km Max – Loop 46.20 ȍ / Km Max Capacitance – 78 pF / m Velocity of Propagation – 66 % Frequency at (MHz) Attenuation ” (db / 100m) 100 13.12 400 27.89 1000 44.29 1500 57.47 1800 60.70 2000 67.26 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Bare Copper conductor. Nominal diameter: 0.813mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 2.90mm. 3 1st Shield: Bonded AP Laminate Shield. Coverage: 100%. Diameter: 2.95mm. 4 2nd Shield: Tinned Copper braid. Coverage: 98%. Outer braid diameter: 3.40mm. 5 Jacket: Black PVC jacket. Nominal diameter: 4.95mm. Numerical identification. ATFC U-JIN / ATFCB D-13 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected] Amphenol Telecom Solutions RG-142/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Characteristic Impedance Maximum Operating Voltage Direct Current Resistance Capacitance Velocity of Propagation Operating Temperature 1 – 50 ± 2 ȍ – 1.4KV – Inner Conductor 640.00 ȍ / Km Max – 96.5 pF / m – 69 % – -55 - 200ºC Reference RG-142/U Diameter Weight kg/km 4.95 ± 0.05 64 (less reel) Bend Radius: 29.7mm Frequency at (MHz) 100 400 1000 3000 5000 Attenuation ” (db / 100m) 18.05 38.39 62.34 114.83 157.48 Cable Constitution No: Description: 1 Inner Conductor: Solid silver-coated Copper-clad steel conductor. Nominal diameter: 0.94mm. 2 Dielectric: Solid PTFE insulation. Nominal diameter: 2.95mm. 3 4 5 1st Shield: Silver-coated Copper braid. Coverage: 95%. Outer braid diameter: 3.52mm. 2nd Shield: Silver-coated Copper braid. Coverage: 93%. Outer braid diameter: 4.11mm. Jacket: Black Fluorinated Ethylene Propylene. Nominal diameter: 4.95mm. Numerical identification. RG-174/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC 1 Characteristic Impedance – 50 ± 5 ȍ Maximum Operating Voltage – 1.5KV Direct Current Resistance – Inner Conductor 318 ȍ / Km Max – Outer Conductor 35 ȍ / Km Max – Loop 353 ȍ / Km Max Capacitance – 101 pF / m Velocity of Propagation – 69 % Reference RG-174/U Diameter Weight kg/km 2.80 ± 0.05 13 (less reel) Bend Radius: 12.7mm Frequency at (MHz) Attenuation ” (db / 100m) 10 10.83 50 19.03 100 27.56 200 41.01 400 62.34 700 88.58 900 101.71 1000 111.55 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Copper-clad steel conductor. Nominal diameter: 7/0.16mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 1.52mm. 3 1st Shield: Tinned Copper braid. Coverage: 90%. Outer braid diameter: 1.95mm. 4 Jacket: Black PVC jacket. Nominal diameter: 2.80mm. Numerical identification. ATFC U-JIN / ATFCB D-14 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected] Amphenol Telecom Solutions RG-178/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Military specification: MIL-C-17/93F. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Characteristic Impedance Maximum Operating Voltage Direct Current Resistance Capacitance Velocity of Propagation Operating Temperature Reference Diameter Weight kg/km RG-178/U 1.80 ± 0.05 9 (less reel) 1 Bend Radius: 10.8mm – 50 ± 2 ȍ – 1KV – Inner Conductor 802.10 ȍ / Km Max – 96.5 pF / m – 69 % – -55 - 200ºC Frequency at (MHz) Attenuation ” (db / 100m) 100 52.49 400 108.27 1000 170.60 3000 308.40 Cable Constitution No: Description: 1 Inner Conductor: Stranded silver-coated Copper-clad steel conductor. Nominal diameter: 7/0.102mm. 2 Dielectric: Solid PTFE insulation. Nominal diameter: 0.84mm. 3 4 1st Shield: Silver-coated Copper braid. Coverage: 96%. Outer braid diameter: 1.37mm. Jacket: Fluorinated Ethylene Propylene. Nominal diameter: 1.80mm. Numerical identification. RG-213/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Reference RG-213/U 1 Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 5KV Direct Current Resistance – Inner Conductor 5.48 ȍ / Km Max – Outer Conductor 4.15 ȍ / Km Max – Loop 9.63 ȍ / Km Max Capacitance – 100 pF / m Velocity of Propagation – 66 % Diameter Weight kg/km 10.30 ± 0.05 163 (less reel) Bend Radius: 61.8mm Frequency at (MHz) Attenuation ” (db / 100m) 10 1.80 50 4.30 100 6.20 200 8.90 400 13.40 700 21.30 900 24.90 1000 26.20 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Stranded bare Copper conductor. Nominal diameter: 7/0.752mm. 2 Dielectric: Solid polyethylene insulation. Nominal diameter: 7.24mm. 3 1st Shield: Bare Copper braid. Coverage: 97%. Outer braid diameter: 7.95mm. 4 Jacket: Black PVC. Nominal diameter: 10.30mm. Numerical identification. ATFC U-JIN / ATFCB D-15 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected] Amphenol Telecom Solutions RG-214/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Characteristic Impedance Maximum Operating Voltage Direct Current Resistance Capacitance Velocity of Propagation Reference RG-214/U 1 – 50 ± 2 ȍ – 5KV – Inner Conductor 5.67 ȍ / Km Max – 105 pF / m – 66 % Diameter Weight kg/km 10.80 ± 0.05 170 (less reel) Bend Radius: 108mm Frequency at (MHz) Attenuation ” (db / 100m) 50 5.58 400 18.05 3000 62.34 Cable Constitution No: Description: 1 Inner Conductor: Stranded silver-coated Copper conductor. Nominal diameter: 7/0.752mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 7.24mm. 3 4 5 1st Shield: Silver-coated Copper braid. Coverage: 96%. Outer braid diameter: 8.04mm. 2nd Shield: Silver-coated Copper braid. Coverage: 98%. Outer braid diameter: 8.84mm. Jacket: Black PVC. Nominal diameter: 10.80mm. Numerical identification. RG-223/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Reference RG-223/U 1 Characteristic Impedance – 50 ± 3 ȍ Maximum Operating Voltage – 1.9KV Direct Current Resistance – Inner Conductor 29.00 ȍ / Km Max – Outer Conductor 8.20 ȍ / Km Max – Loop 37.20 ȍ / Km Max Capacitance – 101 pF / m Velocity of Propagation – 66 % Diameter Weight kg/km 5.40 ± 0.05 58 (less reel) Bend Radius: 57mm Frequency at (MHz) Attenuation ” (db / 100m) 10 3.94 50 9.19 100 13.45 200 19.69 400 28.87 700 39.37 900 45.28 1000 47.57 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Silver-coated Copper conductor. Nominal diameter: 0.88mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 2.95mm. 3 1st Shield: Bare Copper braid. Coverage: 95%. Outer braid diameter: 3.46mm. 4 2nd Shield: Bare Copper braid. Coverage: 95%. Outer braid diameter: 4.00mm. 5 Jacket: Black PVC. Nominal diameter: 5.40mm. Numerical identification. ATFC U-JIN / ATFCB D-16 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected] Amphenol Telecom Solutions RG-316/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC 1 Characteristic Impedance – 50 ± 5 ȍ Maximum Operating Voltage – 1.2KV Direct Current Resistance – Inner Conductor 268.00 ȍ / Km Max – Outer Conductor 29.00 ȍ / Km Max – Loop 297.00 ȍ / Km Max Capacitance – 106 pF / m Velocity of Propagation – 66 % Reference RG-316/U Diameter Weight kg/km 2.75 ± 0.05 14 (less reel) Bend Radius: 15mm Frequency at (MHz) Attenuation ” (db / 100m) 10 9.45 50 18.72 100 24.97 400 49.57 700 67.26 1000 84.35 1200 92.49 1600 109.91 2000 123.03 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Copper-clad steel conductor. Nominal diameter: 0.45mm. 2 Dielectric: Solid Polyethylene insulation. Nominal diameter: 1.56mm. 3 1st Shield: Non-bonded APA laminate shield. Coverage: 100%. Outer braid diameter: 1.70mm. 4 2nd Shield: Tinned Copper braid. Coverage: 95%. Outer braid diameter: 2.01mm. 5 Jacket: Black PVC. Nominal diameter: 2.75mm. Numerical identification. RG-400/U 50 Ohm Coaxial Cable Main Characteristics Weight & Dimension Characteristics Coaxial cable used for switching and transmission network. Military Specification: MIL-C-17/128B. Cable Marking – Manufacturer, Date of manufacture, Part number & Length marking Suitable Connectors – See Section A No. of Coaxes Electrical Characteristics Nominal Attenuation @ 20ºC Characteristic Impedance Maximum Operating Voltage Direct Current Resistance Capacitance Velocity of Propagation Operating Temperature – 50 ± 3 ȍ – (On Request) – Inner Conductor 29.86 ȍ / Km Max – 96.5 pF / m – 69 % – -55 - 200ºC Reference Diameter Weight kg/km RG-400/U 4.95 ± 0.05 74 (less reel) 1 Bend Radius: 29.7mm Frequency at (MHz) Attenuation ” (db / 100m) 100 14.76 400 34.78 1000 55.77 3000 124.67 5000 164.04 10000 255.91 Maximum Value is 104% of Nominal Value Cable Constitution No: Description: 1 Inner Conductor: Stranded Silver-coated Copper conductor. Nominal diameter: 19/0.203mm. 2 Dielectric: Solid PTFE insulation. Nominal diameter: 2.95mm. 3 4 5 1st Shield: Silver-coated Copper braid. Coverage: 94%. Outer braid diameter: 3.52mm. 2nd Shield: Silver-coated Copper braid. Coverage: 93%. Outer braid diameter: 4.11mm. Jacket: Fluorinated Ethylene Propylene. Nominal diameter: 4.95mm. Numerical identification. ATFC U-JIN / ATFCB D-17 Amphenol Africa, Tel: +27 11 783 9517, Fax: +27 11 783 9519, Cell: +27 83 442 0514, Email: [email protected]