RESIDENTIAL & COMMERCIAL
FULL LINE POCKET GUIDE
AmericanWaterHeater.com
RESIDENTIAL TABLE OF CONTENTS NAECA III Guidelines................................................................. 1 Contractor Rewards™............................................................... 2 Residential Water Heater Selection Guide.................................. 3
RESIDENTIAL GAS Polaris® High Efficiency........................................................... 4-5 Nautilus™ Power Vent............................................................. 6-7 Nautilus™ Power Direct Vent................................................... 8-9 Power Flex® Power Vent .................................................... 10-11 PowerFlex® Power Direct Vent............................................ 12-13 Direct Vent.......................................................................... 14-15 High Efficiency.................................................................... 16-17 High Efficiency Flue Damper............................................... 18-19 Atmospheric Vent............................................................... 20-23 High Recovery Atmospheric Vent 75 & 100 Gallon.............. 24-25 Mobile Home Atmospheric Vent......................................... 26-27 Mobile Home Direct Vent.................................................... 28-29 Ultra Low NOx.................................................................... 30-31 Ultra Low NOx Power Vent................................................. 32-33 Ultra Low NOx Direct Vent.................................................. 34-35 Ultra Low NOx High Recovery............................................ 36-37
RESIDENTIAL TANKLESS Tankless Condensing High Efficiency.................................. 38-39 Tankless Condensing High Efficiency.................................. 40-41 Tankless Non-Condensing.................................................. 42-43 Tankless Non-Condensing Ultra-Low NOx.......................... 44-45
RESIDENTIAL HYBRID ELECTRIC High Efficiency Hybrid Electric Heat Pump - 10-Year........... 46-47 High Efficiency Hybrid Electric Heat Pump - 6-Year............. 48-49 High Efficiency Hybrid Electric Heat Pump - 6-Year............. 50-51
RESIDENTIAL ELECTRIC Self-Cleaning...................................................................... 52-53 Standard............................................................................ 54-55 Mobile Home...................................................................... 56-57 Specialty Electric................................................................ 58-59
RESIDENTIAL PUMP & EXPANSION TANKS In-Line, Free-Standing & Horizontal.................................... 42-43 Potable & In-Line Hydronic................................................. 44-45
COMMERCIAL TABLE OF CONTENTS COMMERCIAL GAS Non-Dampered.................................................................. 64-65
GUIDING YOU THROUGH
Polaris® High Efficiency....................................................... 66-67 High Efficiency HCG Series................................................. 68-71
THE NAECA III TRANSITION
Heavy-Duty Low NOx BCG3 Series ................................... 72-75 Ultra-Low NOx BCL Series Heavy-Duty.............................. 76-79 Ultra-Low NOx Single Flue.................................................. 80-81
COMMERCIAL TANKLESS Tankless Non-Condensing.................................................. 82-83 Tankless Non-Condensing Ultra-Low NOx.......................... 84-85 Tankless Condensing High Efficiency.................................. 86-87 Tankless Heavy-Duty.......................................................... 88-89
COMMERCIAL ELECTRIC Light- Duty......................................................................... 90-91 Heavy-Duty Surface Thermostats....................................... 92-93 Heavy-Duty Immersion Thermostats................................... 94-95
The U.S. Department of Energy (DOE) regulates minimum energy efficiency requirements for all brands of water heaters. A new update to the rules for increasing minimum energy efficiency is in effect as of April 16, 2015.
AT AMERICAN, WE’VE PREPARED OUR LINE OF RESIDENTIAL WATER HEATERS TO MEET THE STANDARDS. BUT AS SOMEONE IN THE BUILDING COMMUNITY, YOU NEED TO UNDERSTAND HOW THESE CHANGES IMPACT YOU AS WELL. These design changes require that most residential water heaters under 55 gallons of capacity produced after April 16, 2015 be larger in size. Therefore, they will require more installation space in both single-family and multi-family housing. Most water heaters under 55 gallons are 2˝ larger in height and diameter. Units over 55 gallons will require even more drastic technology changes.
WATER HEATER REPLACEMENT ISSUES?
WE HAVE SOLUTIONS.
COMMERCIAL STORAGE TANKS Standard Jacketed............................................................. 96-97
GAS
WILL THE NEW LARGER DESIGN FIT? IF NOT, YOU HAVE TWO OPTIONS. LESS THAN 55 GALLON
OPTION 1: Use a smaller heater to match the current footprint of your existing heater. You might consider adding a mixing valve on the water heater to increase delivery capacity. OPTION 2: Upgrade to a smaller more efficient tankless unit.
ELECTRIC
THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS CHANGED. MORE THAN 55 GALLON
OPTION 1: Upgrade to one of American’s High Efficiency Options such as tankless.
LESS THAN 55 GALLON
WILL THE NEW LARGER DESIGN FIT? IF NOT,SEE BELOW.
MORE THAN 55 GALLON
OPTION 2: Replace your obsolete model with 2 smaller gas heaters. (Example: two 40-gallon gas units in the place of one 75-gallon gas unit).
OPTION 1: Use a smaller heater to match the current footprint of your existing heater. You might consider adding a mixing valve on the water heater to increase delivery capacity. THE TECHNOLOGY FOR UNITS OVER 55 GALLONS HAS CHANGED. OPTION 1: Upgrade to American’s Hybrid Electric Heat Pump water heater which is 2.5x more efficient as a standard electric. OPTION 2: Replace your obsolete model with 2 smaller electric heaters (Example: Two 40-gallon electrics in the place of one 80-gallon electric).
TO LEARN MORE, VISIT AMERICANWATERHEATER.COM/NAECA
WHY PROFESSIONALS CHOOSE
AMERICAN WATER HEATERS
AMERICAN WATER HEATERS PREMIUM FEATURES. NAECA III READY.
EARN POINTS BY PURCHASING AMERICAN WATER HEATERS It’s free and easy to participate. Enroll online at contractorrewards.com. Eligible products will have a yellow reward code label worth valuable points. Two ways to enter the codes:
1. Download the smart phone app and scan the code. 2. Enter the code at contractorrewards.com. Redeem your points on thousands of reward items.
FREEDOM FREEDOM FREEDOM BRONZE BRONZE BRONZE
FREEDOM FREEDOM FREEDOM SILVER SILVER SILVER
FREEDOM FREEDOM FREEDOM GOLD GOLD GOLD
—G — —O G GO O OD O O— D D— —
—B — —E BB TEE TTT ETT REE — RR— —
—B — —E BB SEE TSS — TT— —
FREEDOM FREEDOM FREEDOM BRONZE BRONZE BRONZE
FREEDOM FREEDOM FREEDOM SILVER SILVER SILVER
FREEDOM FREEDOM FREEDOM GOLD GOLD GOLD
—G — —O G GO O OD O O— D D— —
—B — — EBB TEE TTT ETT REE — RR— —
OPERATING COST
INSTALLATION SPACE REQUIRED nBRONZE n FREEDOM FREEDOM FREEDOM BRONZE BRONZE GO G G O O O D O OD D
HOT WATER OUTPUT
Self-Powered Electronic Gas Valve*
With over 1,000,000 merchandise items, your reward choices are endless.
Heat Trap Nipples** Enhanced Flow Brass Drain Valve** CoreGard™ Advanced Anode Rod Protection** Energy Saving
AMERICAN PROVIDES 4 KEY THINGS
Our Advertising Resource Center allows contractors to develop an easy, affordable and custom advertising campaign to promote their business. Go to www.americanwaterheater.com/ads.
B EBB SEE TSSTT
•
•
•
• • • • •
• • • • • •
• • • • • • • • • • •
Meets NAECA minimums
Continuous Flow* Cutting Edge Technology Industry Leading Efficiency
Applies to some products only
*These features apply to gas products only **These features apply to tank-type products only
Hot Water Output, Cost of Operation, & Installation Space Required estimated based on typical applications/installations. For a more custom analysis of unique installations, visit www.americanwaterheater.com and use our product selector tool.
3. Breadth of Product Line Residential or commercial, we have the most complete line from standard models to the most innovative high efficiency water heaters available.
4. Product Sales Tools We provide contractors access to the sales tools needed to close more sales. Visit americanwaterheater.com/contractor to learn more.
$
n toGOLD nGOLD nn FREEDOM FREEDOM FREEDOM GOLD
Condensing Combustion*
AND BECOME MORE PROFITABLE.
2. Contractor Advertising Tools
B EBB TEE TTE TTT REERR
Electronic User Interface
TO HELP GROW YOUR BUSINESS
Our program rewards our loyal contractors for buying our products. Buy more and get rewarded with prizes.
n to n n FREEDOM FREEDOM FREEDOM SILVER SILVER SILVER
PREMIUM FEATURES: Blue Diamond® Glass Coating** Self-Cleaning Dip Tube**
1. Contractor Rewards™ Program
— —B — —E BB SEE TSS — TT—
$$$ $$
www.AmericanWaterHeater.com
Polaris® High-Efficiency
Residential Gas
SEALED COMBUSTION WITH WOVEN FIBER PREMIX BURNER • Metal fiber burner is designed for clean combustion in high-intensity blue flame mode. Manufactured of refractory steel that resists corrosion. Excellent resistance to thermal and mechanical shock, even at extreme temperatures. Uniform combustion provides excellent heat transfer. Meets Low NOx requirements for Texas and California.
WHISPER QUIET OPERATION • Ultra quiet blower and burner which minimizes noise. • Requires 120 volt 60Hz power supply. • Draws less than 5 Amps.
POWER/DIRECT VENT USING 2” OR 3” PLASTIC PIPE • Direct vents up to 120’ using PVC, CPVC or ABS pipe either thru-the-wall or thruthe-roof. • Optional concentric vent kit available for use thru-the-roof or thru-the-wall.
“PLUG AND PLAY” TECHNOLOGY • No special adjustments are required at initial start up. • Connect air inlet, exhaust outlet, water, electricity and gas, set the temperature and the system functions properly.
Model Number
BTU/h Recovery at Gallon Input Thermal 90°F Rise Capacity Gallon Per Efficiency Gallon Per Hour Hour
Approx. Shipping Weight (lbs)
PG10 34-100-2NV
34
100,000
96%
129
150
PG10 34-130-2NV
34
130,000
96%
168
150
PG10 34-150-2NV
34
150,000
95%
192
150
PG10 50-130-2NV
50
130,000
95%
166
176
PG10 50-150-2NV
50
150,000
95%
192
176
PG10 50-175-3NV
50
175,000
96%
226
180
PG10 50-199-3NV
50
199,000
96%
257
180
Dimensions in Inches Model Number
A
B
Vent Connection
C
D
E
F
PG10 34-100-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG10 34-130-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG10 34-150-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG10 50-130-2NV
62-1/2
22
2 or 3
15-3/4
54-1/2
55
6-1/8
PG10 50-150-2NV
62-1/2
22
2 or 3
15-3/4
54-1/2
55
6-1/8
PG10 50-175-3NV
63-3/4
22
3
15-3/4
55-3/4 56-1/4
6-1/8
PG10 50-199-3NV
63-3/4
22
3
15-3/4
55-3/4 56-1/4
6-1/8
Polaris models meet Low-NOx emission requirements of less than 40 ng/J. For propane (LP) gas change “N” to “P” in the suffix of the model number. The warranty is void for residential models installed in commercial applications.
4
5
Nautilus™ Power Vent
OUTLET
POWER VENT DESIGN FOR INSTALLATION VERSATILITY
Residential Gas
INLET
T & P VALVE
• Modular blower, with 120 volt, 60Hz electrical system (5 amps or less), 6-foot cord with standard 3-prong connector. • Combined horizontal and vertical vent runs terminating through an outside wall, using Schedule 40 PVC pipe as follows: A up to 25 • 2” pipe allows vent runs equivalent feet. G DIAMETER • 3” pipe allows vent runs up to 65 equivalent feet. • 4” pipe allows vent runs up to 128 SIDE INLET equivalent feet. THERMOSTAT SIDE-MOUNTED TAPS FOR DRAIN RECIRCULATING SYSTEMS VALVE • Hot and cold “side taps” allows the Nautilus Power Vent to be used for F “combination” systems for water heating plus space heating, radiant floor heating or other applications requiring a recirculating FRONT VIEW hot water loop.
SIDE OUTLET
H ANODE
HOT
B
K
COLD
J
C
TOP VIEW * INSTALL IN ACCORDANCE WITH LOCAL CODES
D
OUTLET
INLET
E SIDE OUTLET
T & P VALVE
INTELLI-VENT™ GAS CONTROL WITH SILICON NITRIDE HOT SURFACE IGNITOR
ANOD
• Premium-grade hot surface ignitor eliminates standing pilot. • Electronic circuitry provides superior system diagnostics capabilities plus extremely precise temperature controls.
A
B G
DIAMETER
BLUE DIAMOND® GLASS COATING WITH TWO HEAVY DUTY ANODE RODS
SIDE INLET
• Provides superior corrosion resistance compared to the industry-standard glass lining.
THERMOSTAT
GREEN CHOICE® GAS BURNER **Intelli-Vent™ is a registered trademark of Emerson Electric Company.
• Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
* INSTALL IN
DRAIN VALVE
D
F
E FRONT VIEW
SELF-CLEANING DIP TUBE
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE MAXIMUM HYDROSTATIC WORKING PRESSURE: 150 PSI
Model Number
Gallon Capacity
Recovery @ 90°F Rise Gallon Per Hour
BTU Input Per Hour
First Hour Delivery Gallons
Approx. Shipping Weight (lbs)
CODE COMPLIANCE
VG6250T76NV
50
92
76,000
127
210
• Meets UBC, CEC and ICC National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1.
Model Number
6-YEAR LIMITED TANK AND PARTS WARRANTY 6
J
C
• For complete information, consult written warranty or americanwaterheater.com.
VG6250T76NV
Dimensions in Inches A
B
C
D
E
F
G
H
71
68-5/8
52
21
9-1/8
12
22
8
J
K
15-3/4 27
Available in natural gas only. Standard model certified for sea level to 5,300 ft. elevation. Specify high altitude when ordering for use in elevations up to 10,100 ft. Optional Condensate Neutralizer (part number 9007059005).
7
Nautilus™ Power Direct Vent
ROUGH IN DIMENSIONS: 50 GALLON UNIT
• Spiral heat exchanger keeps hot combustion gases in the tank longer to lengthen the heat transfer cycle. • Operates at 96% thermal efficiency which saves money on operating costs compared to standard 80% efficient gas water heater.
POWER DIRECT VENT DESIGN
T&P
ANODE
UPPER SIDE CONNECT
OUTLET
F
A
• Combined vertical and horizontal runs terminating through an outside wall. Vents using PVC, CPVC or ABS pipe. • 2” pipe, vents up to 45 equivalent feet. • 3” pipe, vents up to 128 equivalent feet.
I C
DIAMETER
INLET
B TOP VIEW LOWER SIDE CONNECT
E
CONDENSING DESIGN • 96% efficient condensing design. • Equipped with condensate drain tee.
GAS PIPING CONNECTION
HELICAL INTERNAL HEAT EXCHANGER
Residential Gas
*INSTALL IN ACCORDANCE WITH LOCAL CODES.
D DRAIN
FRONT VIEW
Figure 1: DIMENSIONS FOR 50 GALLON UNIT
ROUGH IN DIMENSIONS: 75 GALLON UNIT
• Allows the Nautilus to be installed as part of a combination space heating/ water heating application.
F INLET
• Large LCD Display. • Precise temperature control. • Advanced diagnostics.
A
UPPER SIDE CONNECT
ADVANCED ELECTRONIC CONTROL
VG6275T100NV
GAS PIPING CONNECTIONS
T&P
C
DIAMETER
ANODE OUTLET
I
AIR INTAKE CONNECTION
SIDE-MOUNTED HOT AND COLD RECIRCULATING TAPS
H
B
CODE COMPLIANCE
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
E
LOWER SIDE CONNECT
• Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar requirements for Ultra-Low NOx emissions requirements of 14 ng/J or 20 ppm. • Meets UBC, CEC and ICC National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1.
DRAIN
D
G
Figure 2: DIMENSIONS FOR 75 GALLON UNIT
Model Number
Gallon Capacity
Recovery @ 90°F Rise Gallon Per Hour
BTU Input Per Hour
Vent Size
Approx. Shipping Weight (lbs)
VG6250T100NV
50
129
100,000
2 or 3
255
VG6275T100NV
75
129
100,000
2 or 3
382
Model Number
Dimensions in Inches A
B
C
D
E
F
VG6250T100NV
66-3/4
49-1/4
22
15-3/4
3
8
VG6275T100NV
65-1/4
45-5/8
27-3/4
16
3-3/4
8
Available in Propane (LP) gas. Specify when ordering Propane (LP) gas. Models certified for sea level to 10,100 ft. elevation. Optional condensate neutralizer kit available (part number 9007959005).
8
9
Residential Gas
PowerFlex® Power Vent VERSATILE POWER VENT DESIGN • All models feature an exclusive 3-position rotatable blower outlet which adds flexibility. • Combined horizontal and vertical runs up to 180 equivalent feet with 4˝ diameter venting (ABS, PVC, CPVC and polypropylene). • All models are equipped with a protected sensor that detects the presence of flammable vapors and automatically disables the burner to prevent ignition. • Air intake snorkel elevates the inlet location of combustion air to prevent flammable vapors from entering the sealed combustion chamber.
ANODE
D
COLD
HOT
HOT SURFACE IGNITOR • More robust and reliable than standing pilot, and reduces energy consumption.
ØC
BUILT-IN HEAT TRAPS ON THE WATER INLET AND OUTLET REDUCE THE AMOUNT OF HEAT LOST THROUGH PIPING 2-INCH, THICK, “ENVIRONMENTALLY-FRIENDLY” FOAM INSULATION REDUCES THE AMOUNT OF HEAT LOSS AND CONTRIBUTES TO OVERALL ENERGY EFFICIENCY
G
F
E
USER-FRIENDLY • State-of-the-art electronic gas control provides more precise temperature control. • LED control light displays operation status and diagnostics information.
Model Number
Series
A
H
Recovery BTU Approx. Energy @ 90°F Input First Gallon Shipping Factor Rise Gallon Hour Capacity Weight (EF) Gallon Per Per Rating (lbs) Hour Hour
PVG62-40S40-NVS 200
40
0.70
44.7
40,000
73
174
ENHANCED-FLOW BRASS DRAIN VALVE
PVG62-40T50-NVS 200
40
0.70
55.9
50,000
90
176
PVG62-50S40-NVS 200
50
0.70
44.7
40,000
90
198
AVAILABLE IN NATURAL GAS AND PROPANE
PVG62-50T50-NVS 200
50
0.70
55.9
50,000
96
192
PVG62-50S62-NVS 200
50
0.70
69.3
62,000
110
212
210
75
N/A
80.4
76,000
N/A
277
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com. 10
B
†PVG62-75T76-NV
Model Number
Dimensions in Inches A
B
C
D
E
PVG62-40S40-NVS
59
49-5/8
22
29-1/8
11
13-1/4 42-1/2 15-1/4
F
G
PVG62-40T50-NVS
68-1/2
59-1/4
20
27-1/8
11
13-1/4 53-1/8 15-1/4
PVG62-50S40-NVS
60-1/8
50-3/4
24
31-1/8
11
13-1/4 43-3/4 15-1/4
PVG62-50T50-NVS
68-1/8
58-3/4
22
29-1/8
11
13-1/4 51-3/4 15-1/4
PVG62-50S62-NVS
61-1/8
52
24
31-1/8
11
13-1/4 44-1/2 15-1/4
†PVG62-75T76-NV
70-5/8
61-1/4
26
33-1/8
11
13-1/4
53
H
15-1/4
Available in propane (LP) gas. Specify when ordering propane (LP) gas. Side connections are standard on PVG62-50S62-NVS and PVG62-75T75-NV. All models certified from sea level to 10,100 ft. elevation. +PVG62-75T76-NV is not ENERGY STAR® Qualified.
11
PowerFlex® Power Direct Vent
Residential Gas
POWER DIRECT VENT DESIGN • Combined horizontal and vertical runs up to 180 equivalent feet with 4˝ diameter venting (ABS, PVC, CPVC and polypropylene).
D
• Two-pipe sealed combustion system uses outside air, eliminating problems caused by insufficient indoor ventilation.
GREEN CHOICE® GAS BURNER • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
HOT SURFACE IGNITOR • More robust and reliable than standing pilot, and reduces energy consumption.
SELF-CLEANING DIP TUBE USER FRIENDLY
C
A
• State-of-the-art electronic gas control provides more precise temperature control.
B
• LED control light displays operation status and diagnostics information.
G
ENHANCED-FLOW BRASS DRAIN VALVE CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
F
H
E
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended.
Model Number
BTU Recovery First Approx. Input @ 90°F Gallon Energy Hour Shipping Series Per Hour Rise Capacity Factor Rating Weight Natural Gallon Per Gallon (lbs) Gas Hour
PDVG62-40S40-NV
200
40
40,000
0.71
71
45.2
174
PDVG62-50T45-NV
200
50
45,000
0.70
93
50.3
192
PDVG62-50T62-NV
200
50
62,000*
0.71
115
72.6
200
†PDVG62-75T76-NV 210
75
76,000
N/A
N/A
82.4
277
Model Number
Dimensions in Inches A
B
C
6-YEAR LIMITED TANK AND PARTS WARRANTY
D
E
PDVG62-40S40-NV
58-1/4
49-5/8
22
29-7/8
11
13-1/4 42-1/2 15-1/4
• For complete information, consult written warranty or americanwaterheater.com.
PDVG62-50T45-NV
67-1/2
58-3/4
22
29-7/8
11
13-1/4 51-3/4 15-1/4
PDVG62-50T62-NV
69
60-1/4
22
29-7/8
11
13-1/4 52-3/4 15-1/4
61-1/2
26
33-7/8
11
13-1/4
†PDVG62-75T76-NV 70-5/8
F
G
53
H
15-1/4
*Propane model has input of 58,000 BTU/hr. Available in propane (LP) gas. Specify when ordering propane (LP) gas. Side connections standard on 50T62 and 75T76 models. Side connections available on 40S40 and 50T45 models. All models are certified from sea level to 10,100 ft. elevation. † PDVG62-75T76-NV is not ENERGY STAR® Qualified.
12
13
Direct Vent
Residential Gas 75 GAL. VENT TERMINATION CAP IS NOT INTERCHANGEABLE WITH VENT CAP ON 40 & 50 GAL. MODELS
DIRECT VENT DESIGN • One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is FVIR compliant.
EXTERIOR WALL
G
T&
P
• Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed.
DR
AI
MINIMUM VENT 17’ MAXIMUM VENT 80”
TOP
GREEN CHOICE GAS BURNER ®
6”DIA. ON 40 & 50 GAL MODELS out pr ior noti ce.
3/4” MALE NPT OUTLET & INLET
SELF CLEANING DIP TUBE
EXTERIOR WALL
COREGARD™ ANDODE ROD PUSH BUTTON PIEZO IGNITOR HEAT TRAP NIPPLES
N
42° 21°
TOP
INTELLIGENT CONTROL LOGIC
• Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
COLD
HOT
Side Tap and T&P
A
FRONT
C B F
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes.
D
H
E
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1 • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
DESIGN-CERTIFIED BY CSA INTERNATIONAL • Certified at 300 PSI test pressure and 150 PSI working pressure. Listed according to ANSI Z21.10.1-CSA 4.1 standards governing storage tank-type gas water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
14
Model Number
Recovery @ 90˚ Vent Rise Outlet Gallon Per Hour
First BTU Gallon Hour Energy Input Capacity Rating Factor Per Gallon Hour
Approx. Shipping Weight (lbs)
DVG62-40S38-NOV
40
72
0.63
38,000
41
Co-Axial
DVG62-50T40-NOV
50
91
0.62
40,000
43
Co-Axial
200
DVG62-50T47-NOV
50
92
0.61
47,000
51
Co-Axial
215
Model Number
178
Dimensions in Inches A
DVG62-40S38-NOV 64
B
C
49-3/4 22
D
E
F
*G
H
13-1/4
15-1/4
42-1/2
29
15-1/4
DVG62-50T40-NOV
73
59
22
13-1/4
15-1/4
51-3/4
29
15-1/4
DVG62-50T47-NOV
74
60
22
13-1/4
15-1/4
52-3/4
29
15-1/4
Dual-channel system has 3” vent pipe inside 6” air intake pipe. All models have 2” foam cavity. Water connection is 3/4” male on all models. 40 and 50 gallon models are 8” on center. *Allow 29-1/2" for front to back dimension for gas control and air intake pipe at the rear of the heater. All models are available in propane (LP) gas. Specify when ordering. All models certified from sea level to 7,700 ft. elevation. All models are available with side loop sittings. Add "L" to suffix of model (Example: 40S38NOLV).
15
DRAFT HOOD
High Efficiency
Residential Gas
T&P VALVE
PRESSURIZED COMBUSTION C SYSTEM
A
F
B
• Allows for easy replacement of standard atmospheric vent heaters. • Easily connects to existing B-vent
ANODE ROD
G
INSTALLATION FRIENDLY GAS VALVE
H
ON/OFF SWITCH
HOT CONNECTION
DRAIN VALVE
FAN-ASSISTED, CATEGORY 1 APPLIANCE D
COLD CONNECTION
E
• Plugs into standard 110/120V outlet (10 foot power cord included)
TOP VIEW
24V ELECTRONIC CONTROL FRONT VIEW
1/2”
ELECTRONIC IGNITION
DRAFT HOOD
LCD USER INTERFACE
T&P VALVE
• Easy-to-read, eye level display • Simple temperature settings and adjustments
C
• Service diagnostics are in plain text
POWERED ANODE ROD
A
F
B GAS VALVE
ENHANCED-FLOW BRASS DRAIN VALVE
D
GREEN CHOICE® GAS BURNER • Patented eco-friendly gas burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J
• Meets UBC, CEC and HUD National Codes • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1 • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com
16
HOT CONNECTION
DRAIN VALVE
SELF-CLEANING DIP TUBE
CODE COMPLIANCE
H
ON/OFF SWITCH
FRONT VIEW
Model Number
First Recovery @ Approx. Energy BTU Input Gallon Hour 90°F Rise Shipping Factor Gallon Per Capacity Rating Gallon Per Weight (EF) Hour Gallons Hour (lbs)
PCG6240T403NOV
40
70
0.70
40,000
43
157
PCG6250T403NOV
50
81
0.70
40,000
43
171
B
C
D
Dimensions in Inches Model Number
Foam Thickness
A
PCG6240T403NOV
2
61-3/4
58
20
13-1/4
PCG6250T403NOV
2
60-5/8
57-1/8
22
13-1/4
Model Number
Dimensions in Inches E
F
G
H
Draft Hood
PCG6240T403NOV
8
51-1/2
23-1/4
25
3 or 4
PCG6250T403NOV
8
50-1/2
25-1/4
27
3 or 4
Available in natural gas only. Water connection is ¾” on all models. All models are certified from sea level to 10,100 ft. elevation. Requires 120 VAC power supply.
17
Residential Gas
High Efficiency Flue Damper ANODE ROD*
AUTOMATIC FLUE DAMPER
HOT CONNECTION
• Increases efficiency as it automatically opens and closes to reduce heat loss in the standby mode.
COLD CONNECTION
ELECTRONIC GAS CONTROL E C
DIAGNOSTICS ELECTRONIC IGNITION SELF-CLEANING DIP TUBE GREEN CHOICE® GAS BURNER • Patented eco-friendly gas burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
T&P VALVE 1/2" GAS CONNECTION
COREGARD™ ANODE ROD
A
B
F
ENHANCED-FLOW BRASS DRAIN VALVE D
BLUE DIAMOND® GLASS COATING CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
* Location for optional top-mounted T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1 • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
Model Number
BTU First Recovery @ Approx. Energy Input Gallon Hour 90°F Rise Shipping Factor Gallon Capacity Rating Gallon Per Weight (EF) Per Hour Gallons Hour (lbs) Natural*
Tall Models FDG62 40T40 3NOV
40
67
0.67
42
40,000
152
FDG62 50T40 3NOV
50
81
0.67
42
40,000
167
FDG62 40S40 3NOV
40
67
0.67
42
40,000
149
*FDG62 50S40 3NOV
50
88
0.67
42
40,000
175
Short Models
Dimensions in Inches Model Number
A
B
Draft Foam Hood Thickness Outlet
C
D
E
F
FDG62 40T40 3NOV
64-1/4 58-1/4 20
13
8
51-3/4
2
3 or 4
FDG62 50T40 3NOV
63-1/2 57-1/4 22
13
8
50-1/4
2
3 or 4
13
8
41
2
3 or 4
42-1/2
2
3 or 4
Tall Models
Short Models FDG62 40S40 3NOV *FDG62 50S40 3NOV
54
47-3/4 22
55-3/4 49-1/2 24 13-1/4 8
Requires 120 VAC power supply. Water connection is ¾” on all models. When ordering top-mounted T&P, change suffix to NO (example: FDG62-50S40-3NO). *FDG62-50-40-3NOV available in natural gas only. All other models available in propane (LP) gas. All models are certified to 10,100 ft. elevation. Available in propane (LP) gas. Specify when ordering propane (LP) gas.
18
19
Atmospheric Vent
Residential Gas
INTELLIGENT CONTROL LOGIC • *Not available on 60,000 BTU input models (G62-50T60 and G62-55T60).
SELF-CLEANING DIP TUBE
Model Number
First BTU BTU Recovery Approx. Gallon Hour Energy Input Input 90° Rise Shipping Capacity Rating Factor Natural Propane Gallon Per Weight Gallon Gas Gas Hour (lbs)
Tall Models †GB61-30T35
30
64
0.63
35,500
32,000
37
132
COREGARD™ ANODE ROD
G62-30T30
30
55
0.63
30,000
29,000
31
108
G62-40T34
40
56
0.62
34,000
33,000
36
125
PUSH-BUTTON PIEZO IGNITOR
†GB61-40T40
40
70
0.62
40,000
36,000
42
158
G62-40T40
40
70
0.62
40,000
36,000
42
132
G61-50T40
50
82
0.61
40,000
36,000
43
161
G62-50T40
50
82
0.62
40,000
36,000
43
161
G62-50T50*
50
92
0.60
50,000
45,000
54
165
†G62-50T60*
50
98
0.60
60,000
54,000
65
190
ENHANCED-FLOW BRASS DRAIN VALVE HEAT TRAP NIPPLES BLUE DIAMOND GLASS COATING
Short Models †GB61-30S35
30
56
0.63
35,500
32,000
37
110
CODE COMPLIANCE
G62-30S30
30
50
0.63
30,000
29,000
31
116
• Meets UBC, CEC and HUD National Codes.
†GB61-40S40
40
67
0.62
40,000
36,000
41
134
G62-40S40
40
67
0.62
40,000
36,000
41
146
• Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/ IENSA 90.1.
G62-50S40
50
93
0.60
40,000
40,000
43
177
®
• Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
DESIGN-CERTIFIED BY CSA INTERNATIONAL • Certified at 300 PSI test pressure and 150 PSI working pressure.
Water connection is 3/4” on all models. All models available in propane (LP) gas. †Models ship with supplied insulation blanket. Extended tank warranties available. For 10-year tank & 6-year parts limited warranty, change “6” to “10: in the model number. Example: G102-40T40. *Optional side-mounted recirculating taps. All models approved for installation from sea level to 10,100 ft. elevation.
Dimensions and line drawing on the following pages.
• Listed according to ANSI Z21. 10.1-CSA 4.1 standards governing storage tank-type gas water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
20
21
Atmospheric Vent (continued)
Residential Gas
ANODE ROD (OPTIONAL T&P LOCATION)
Model Number
Dimensions in Inches A
B
C
D
E
Tall Models 60-1/2
58
16
12
8
G62-30T30
60
56-1/2
17-3/4
11-1/4
8
G62-40T34
60-1/2
57
19-3/4
11-1/4
8
†GB61-40T40
61-3/4
58-1/4
18
12
8
G62-40T40
62
58-1/2
19-3/4
11-1/4
8
G61-50T40
61
57-1/2
21
11-1/4
8
†GB61-30T35
HOT CONNECTION (ANODE OUTLET ON T&P MODELS)
COLD CONNECTION E
G62-50T40
61
57-1/2
22
11-1/4
8
G62-50T50*
60-3/4
57-1/4
22
12
8
†G62-50T60*
65-1/2
61
22
13-1/2
8
Short Models 50
46-1/2
18
12
8
G62-30S30
49-1/4
45-3/4
19-3/4
11-1/4
8
†GB61-40S40
51-1/2
48
22
12
8
52-1/2
49
22
11-1/4
8
53-1/4
49-3/4
24
13-1/4
8
†GB61-30S35
G62-40S40 TOP VIEW G62-50S40
HOT CONNECTION
Model Number
Dimensions in Inches F
G
H
†GB61-30T35
51-3/4
N/A
N/A
3 to 4
G62-30T30
49-1/4
N/A
N/A
3 or 4
G62-40T34
50-1/4
N/A
N/A
3 or 4
52
N/A
N/A
3 or 4
N/A
N/A
3 or 4
N/A
N/A
3 or 4
ANODE ROD
Draft Hood
Tall Models
A
H
C
F
†GB61-40T40
COLD 51-3/4 CONNECTION
G62-40T40
E D
G
FVG-50T65-4NOV
G61-50T40
50-1/2
G62-50T40
50-1/2
N/A
N/A
3 or 4
G62-50T50*
50-1/2
50-1/2
14-1/4
4
†G62-50T60*
54-1/4
14-1/4
50-1/4
4
Short Models †GB61-30S35
40
N/A
N/A
3 or 4
G62-30S30
39
N/A
N/A
3 or 4
41-1/4
N/A
N/A
3 or 4
G62-40S40
42
N/A
N/A
3 or 4
G62-50S40
41-1/4
N/A
N/A
3 or 4
†GB61-40S40
Water connection is 3/4” on all models. All models available in propane (LP) gas. †Models ship with supplied insulation blanket. Extended tank warranties available. For 10-year tank & 6-year parts limited warranty, change “6” to “10: in the model number. Example: G102-40T40. *Optional side-mounted recirculating taps. All models approved for installation from sea level to 10,100 ft. elevation.
22
23
High Recovery Atmospheric Vent 75 & 100 Gallon HOT WATER
Residential Gas TOP VIEW
COLD WATER INLET
INLET HIGHEST RECOVERIES
• Capacity/input combinations up to 98 gallons/75,000 BTU’s to produce recoveries of up to 81 gallons per hour.
E
T&P
TEMPERATURE AND PRESSURE RELIEF VALVE
FULLY AUTOMATIC CONTROLS WITH SAFETY SHUTOFF DRAIN
• Requires no electrical connections VALVE • Fixed automatic gas shutoff device for added safety.
C
F
B
GREEN CHOICE® GAS BURNER
H
A
• Patented eco-friendly gas burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J. D
SELF-CLEANING DIP TUBE
COLD
HOT
HOT WATER INLET
DRAIN VALVE
COLD WATER INLET
GAS INLET
T&P
G
COREGARD ANODE ROD
TE AN RE
™
DRAIN VALVE
PUSH-BUTTON PIEZO IGNITOR FRONT VIEW
C
BLUE DIAMOND GLASS COATING ®
F
B H
A
ENHANCED-FLOW BRASS DRAIN VALVE CODE COMPLIANCE
D
• Meets UBC, CEC and ICC National Codes.
G
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE MAXIMUM HYDROSTATIC WORKING PRESSURE 150 PSI DESIGN-CERTIFIED BY CSA INTERNATIONAL • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21. 10.1-CSA 4.1 standards governing storage tanktype gas water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com. 24
FRONT VIEW Model Number G62-75T75-4NOV G62-100T77-4NOV Model Number G62-75T75-4NOV G62-100T77-4NOV Model Number G62-75T75-4NOV G62-100T77-4NOV
Gallon BTU Input Recovery @ 90°F Approx. Shipping Capacity Natural Gas Rise Gallon Per Hour Weight (lbs) 74 98
75,100 75,100
81 81
275 350
Dimensions in Inches A
B
C
D
E
61 68-1/2
58-1/2 66-1/2
26-1/2 27-3/4
15-3/16 15-3/16
16 16
Dimensions in Inches F
G
H
Draft Hood
50-1/4 57-3/8
15-1/2 N/A
50-1/4 N/A
4 4
Water connection is 1” male NPT on the G62-75T75-4NOV and 1-1/4” on the G62100T77-4NOV. For 10-year tank & 6-year parts limited warranty, change “6” to “10” in the model number (example: G102-75T75-4NOV). All models available in propane (LP) gas. All models certified from sea level to 7,700 ft. elevation.
25
Mobile Home Atmospheric Vent
Residential Gas
COMPLIES WITH HUD STANDARDS FOR MANUFACTURED HOUSING INSTALLATION GAS CONTROL CONVERTIBLE FOR NATURAL AND PROPANE GAS • For flexibility to meet the varying needs of manufactured housing installations.
SIDE-MOUNTED 3/4” COLD WATER INLETS
ANODE ROD
HOT CONNECTION COLD CONNECTION
• For flexibility to meet the varying needs of manufactured housing installations. • Top-mounted 3/4” hot water outlet.
GREEN CHOICE® GAS BURNER
DRAFT HOOD
• Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
T&P VALVE
COREGARD™ ANODE ROD BLUE® DIAMOND GLASS COATING
C
C
E
ENHANCED-FLOW BRASS DRAIN VALVE CODE COMPLIANCE
D
• Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
Model Number
First Gallon Hour Capacity Rating Gallon
• For complete information, consult written warranty or americanwaterheater.com.
Recovery Btu Input Approx. @ 90°F Btu Input Per Hour Shipping Rise Per Hour Natural Weight Gallon Per Propane Gas (lbs) Hour
MHG62-30T30
30
54
0.63
31
30,000
29,000
129
MHG62-40T40
40
71
0.62
41
40,000
36,000
153
E
Draft Hood Outlet
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE 6-YEAR LIMITED TANK AND PARTS WARRANTY
Energy Factor
Dimensions in Inches Model Number
Insulation
A
B
C
D
MHG62-30T30
2
60
56-1/2
17-3/4
11-1/4
49-1/4
3 or 4
MHG62-40T40
2
62
58-1/2
19-3/4
11-1/4
51-3/4
3 or 4
All models ship from the factory for use with natural gas, a complete propane burner is supplied for converting to propane gas. All models are certified from sea level to 10,100 ft. elevation. No option available for top T&P.
26
27
Mobile Home Direct Vent
Residential Gas
COMPLIES WITH HUD STANDARDS FOR MANUFACTURED HOUSING INSTALLATION GAS CONTROL CONVERTIBLE FOR NATURAL AND PROPANE GAS • For flexibility to meet the varying needs of manufactured housing installations.
DIRECT VENT MODELS PACKAGE WITH BOTTOM INTAKE AIR VENT • To draw all combustion make-up air from outside the structure.
OPTIONAL DUCTED AIR INLET KIT FOR DIRECT VENT MODELS • For use when water heater is installed over a basement. • Provisions for horizontal air inlet ducting.
SIDE-MOUNTED ¾” COLD WATER INLET GREEN CHOICE® GAS BURNER • Patented eco-friendly burner design reduces NOx emissions up to 33% and complies with Low-NOx emission requirements of less than 40 ng/J.
SELF-CLEANING DIP TUBE COREGARD™ ANODE ROD ENHANCED-FLOW BRASS DRAIN VALVE BLUE DIAMOND® GLASS COATING CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U. S Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
6-YEAR LIMITED TANK AND 2-YEAR PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com
28
Model Number
Btu Recovery First Input Approx. @ 90°F Btu Input Gallon Hour Energy Per Shipping Rise Per Hour Capacity Rating Factor Hour Weight Gallon Propane Gallon Natural (lbs) Per Hour Gas
MHDV-62-30T30-3NV
30
49
0.63
31
30,000
29,000
129
MHDV-62-40T32-3NV
40
61
0.62
33
32,000
29,000
153
MHDV-62-50T40-3NV
50
77
0.60
39
40,000
37,000
168
Dimensions in Inches Model Number
Insulation
MHDV-62-30T30-3NV
2
MHDV-62-40T32-3NV
2
MHDV-62-50T40-3NV
2
B
C
D
61
58
18
13 14-1/4 52-1/2
3
61-3/4 58-3/4 20
13 14-1/4 52-1/4
3
13 14-1/4
3
60
57
22
E
F
Draft Hood Outlet
A
50
All models ship from the factory for use with natural gas, a complete propane burner is supplied for converting to propane gas. No option available for top T&P. Water connection-3/4” on all models. All models approved for installation from sea level to 5,400 ft. elevation.
29
Ultra-Low NOx
Residential Gas ANODE ROD (OPTIONAL T&P LOCATION)
INTELLIGENT CONTROL LOGIC
HOT CONNECTION (ANODE OUTLETON TOP T&P MODELS)
HIGH ENERGY FACTORS • Eco-friendly non-CFC foam insulation, heat traps and specially designed combustion chamber combine to produce a high Energy Factor for maximum savings on operating costs.
COLD CONNECTION E
GREEN CHOICE® GAS BURNER • Enhanced Ultra-Low NOx burner complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10 ng/J.
T&P VALVE C
F
H
1/2" GAS CONNECTION
A
B
SELF-CLEANING DIP TUBE
G
D
COREGARD ANODE ROD ™
Maximum Hydrostatic Working Pressure: 150 PSI
PUSH-BUTTON PIEZO IGNITOR HEAT TRAP NIPPLES
Model Number
BLUE DIAMOND® GLASS COATING
TALL MODELS
First Hour BTU Input Energy Rating Natural Factor Gallon Gas
Recovery @ 90° Rise Gallon Per Hour
Approx. Shipping Weight (lbs)
GU61-30T30
30
55
0.63
33,000
34
108
GU62-30T30
30
52
0.63
30,000
31
126
GU61-40T40
40
74
0.62
40,000
41
132
CODE COMPLIANCE
GU62-40T40
40
70
0.62
40,000
41
132
• Meets UBC, CEC and HUD National Codes.
GU61-50T40
50
91
0.60
40,000
41
161
GU62-50T40
50
85
0.62
40,000
41
161
GU62-50T50*
50
98
0.60
50,000
51
177
40
69
0.62
40,000
41
138
ENHANCED-FLOW BRASS DRAIN VALVE
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy Conservation Act (EPCA), as amended.
DESIGN-CERTIFIED BY CSA INTERNATIONAL
SHORT MODELS GU62-40S40
Dimensions in Inches Model Number
A
B
C
D
E
F
58
16
12
G*
H*
Draft Hood
TALL MODELS GU61-30T30
61-3/4
8
51-3/4
N/A
N/A
3 to 4
GU62-30T30
60
56-1/2 17-3/4 11-1/4
8
49-1/4
N/A
N/A
3 to 4
GU61-40T40
62
58-1/2 17-3/4 11-1/4
8
51-3/4
N/A
N/A
3 to 4
• Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to ANSI Z21. 10.1-CSA 4.1 standards governing storage tanktype gas water heaters.
GU62-40T40
62
58-1/2 19-3/4 11-1/4
8
51-3/4
N/A
N/A
3 to 4
GU61-50T40
61
57-1/2 19-3/4 11-1/4
8
50-1/2
N/A
N/A
3 to 4
GU62-50T40
61
57-1/2
22
11-1/4
8
50-1/2
N/A
N/A
3 to 4
GU62-50T50*
61
57-1/2
22
11-1/4
8
50-1/2 12-1/4 50-1/2
6-YEAR LIMITED TANK AND PARTS WARRANTY
SHORT MODELS 51-1/2 47-3/4
22
12
8
41-1/4
• For complete information, consult written warranty or americanwaterheater.com.
30
Gallon Capacity
GU62-40S40
N/A
N/A
4 3 to 4
All models may be ordered from the factory with top T&P valve as an option. *Side loop connections are standard on model GU62-50T50. Models with a ring base (GU62-40S40 and GU61-30T30) are certified from sea level to 7,700 ft. elevation. Models with a leg base (GU61-40T40, GU61-50T40, GU62-30T30, GU62-40T40, GU6250T40 and GU62-50T50) are certified from sea level to 5,400 ft. elevation.
31
BLOWER
Residential Gas
Ultra-Low NOx Power Vent POWER VENTING MADE SIMPLE • Thru-the-Wall of Thru-the-Roof power venting using either 2” or 3” PVC, ABS or CPVC vent pipe.
INTELLI-VENT™ GAS CONTROL • Advanced electronics for more precise control of water temperature and easy to understand system diagnostics.
40-GAL. = 25" 50-GAL. = 27"
EXHAUST OUTLET
IGNITOR
COMBINATION THERMOSTAT/ECO • Utilizes an intermittent ignition gas valve (no standing pilot) with thermistor temperature sensor and built-in high E temperature cut off
QUIET AND EFFICIENT BLOWER
BLOWER
• Factory-installed 6-foot power cord with standard 3-prong male connector provided. Electrical requirements; 110/120 VAC power source, less than 5 amp draw.
SELF-CLEANING DIP TUBE • Reduces lime sediment buildup and maximizes hot water output. Made from long-lasting PEX cross-linked polymer.
COREGARD™ ANODE ROD
40-GA 50-GA
GREEN CHOICE® GAS BURNER • Complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10 ng/J.
IGNITOR
ENHANCED-FLOW BRASS DRAIN VALVE
E
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA) as amended.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
Model Number PVUG62-40T42-NV PVUG62-50T42-NV
First Hour Recovery @ BTU Approx. Gallon Rating Energy 90°F Rise Input Shipping Capacity Gallon Per Factor Gallon Per Gallon Weight Hour Hour Per Hour (lbs) 40 50
69 81
0.68 0.68
42.6 42.6
42,000 42,000
170 207
Dimensions in Inches Model Number PVUG62-40T42-NV PVUG62-50T42-NV
A
B
C
D
E
Draft Hood
20 22
66-7/8 66-8/8
58-5/8 57-7/16
51-1/2 51
12-1/4 12-1/4
2 or 3 2 or 3
No option available for top T&P valve.
32
33
Residential Gas
Ultra-Low NOx Direct Vent FLAMMABLE VAPOR RESISTANT/ DIRECT VENT SEALED COMBUSTION SYSTEM
PROMAX ULTRA-LOW NOx DIRECT VENT
DURABLE, ULTRA-LOW NOX BURNER CONSTRUCTION
TOP VIEW 5˝
NON-CFC FOAM INSULATION • The tank is surrounded by a thick coat of non-CFC polyurethane foam to trap heat inside the tank, saving energy.
¾” TOP WATER CONNECTIONS AND SIDE SPACE HEATING CONNECTIONS
HOT OUTLET
E
17˝/22˝ MIN. 80˝ MAX. HORIZONTAL VENT
COLD INLET
MAX. HEIGHT IS 68˝ ABOVE TOP OF HEATER
THRU-THE-WALL INSTALLATION
½” GAS CONNECTION COREGARD™ ANODE ROD BLUE DIAMOND® GLASS COATING ENHANCED-FLOW BRASS DRAIN VALVE
OUTLET
C
T&P T&P VALVE VALVE
A B
F H
GAS VALVE
GREEN CHOICE® GAS BURNER • Complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less that 10 ng/J.
D
INLET SIDE VIEW
G FRONT VIEW
CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE 6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
Model Number
Gallon Capacity
First Hour Rating Gallon
DVUG62-40S36-NV
40
59
0.62
39
36,000
179
DVUG62-50T38-NV
50
81
0.62
41
38,000
193
Recovery @ Approx. BTU Energy 90°F Rise Shipping Input Per Factor Gallon Per Weight Hour Hour (lbs)
Dimensions in Inches Model Number
Concentric Vent Connection
A
B
C
DVUG62-40S36-NV DVUG62-50T38-NV
3 or 5 3 or 5
65-1/4 73-1/2
50-1/2 58-1/2
22 22
Model Number DVUG62-40S36-NV DVUG62-50T38-NV
Dimensions in Inches D
E
F
G
H
13-1/2 13-1/2
30 30
43-7/8 52-1/4
15 15
45 53
No option available for top T&P valve. All models have ¾” top water connections and come standard with side loop fittings. All models are certified from sea level to 7,700 ft.elevation.
34
35
Residential Gas
Ultra-Low NOx High Recovery K HOT WATER
OUTLET FULLY AUTOMATIC CONTROLS WITH SAFETY SHUTOFF
TOP VIEW
K COLD WATER INLET
F
H
HEAVY GAUGE STEEL JACKET J TEMPERATURE AND PRESSURE RELIEF VALVE
BLUE DIAMOND® GLASS COATING DRAIN VALVE
FOAM INSULATION
D
ULTRA-LOW NOX EMISSIONS • Complies with SCAQMD Rule 1146.2 and A other Air Quality Management Districts with similar requirements of 14 ng/J or 20 ppm.
EASY-TO-INSTALL
C
COLD
HOT G B
DRAIN VALVE K HOT WATER OUTLET
L GAS INLET
E
• Completely factory-assembled. Only gas, M water and vent connections need to be made. All connections are located in front and top of heaters for ease-of-installation and service.
K COLD WATER INLET
F
J
TEMPE AND P RELIE
DRAIN VALVE
COREGARD™ ANODE ROD • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.
D B A
MAXIMUM PRESSURE
DR
• 150 PSI.
MAXIMUM GAS INLET PRESSURE
E
• 14” W.C.
M
CODE COMPLIANCE • The Ultra-Low NOx atmospheric vent residential gas water heater meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and Current Edition ASHRAE/ IESNA 90.1.
6-YEAR LIMITED TANK AND PARTS WARRANTY
Recovery @ 90°F BTU Input Rise Gallon Per Per Hour Hour
Model Number
Gallon Capacity
†UG62-75T75-4NV **
74
81
75,100
285
UG62-100T75-4NV *
98
82
75,100
350
• For complete information, consult written warranty or americanwaterheater.com.
Approx. Shipping Weight (lbs)
Dimensions in Inches Model Number †UG62-75T75-4NV** UG62-100T75-4NV *
A
B
C
D
E
F
62-1/16 70-1/2
58 66-1/2
29-1/2 30-15/16
25-1/4 27-3/4
15-7/8 15-3/16
4 4
Dimensions in Inches Model Number †UG62-75T75-4NV** UG62-100T75-4NV *
G
H
J
K
L
M
15-1/4 15-3/4
16 16
2 1-1/4
1 1-1/4
1/2 1/2
12-1/2 11-15/16
*Recovery rating based on 81% thermal efficiency. **Recovery rating based on 80% thermal efficiency. † The UG62-75T75-4NV comes standard with side loop fittings for use with hydronic heating applications.
36
37
Residential Gas
Tankless Condensing High Efficiency
INDOOR MODEL
INDOOR MODEL
ENERGY STAR® QUALIFIED
Front view
Side view
13-7/8" (352mm) 10" (254mm) 6-1/4" (158.5mm) 4" (102mm) 4" (102mm)
2-9/16" (64.8mm) 2-3/4" (70.2mm)
CONDENSING TECHNOLOGY PROVIDES 0.93 ENERGY FACTOR (EF)
10-13/16" (274.6mm) 10-5/16" (262.2mm) 6" (152.1mm)
58.4
24" (609.4mm)
• Complies with SCAQMD Rule 1146.2 NOx emission requirements of 14 ng/J or 20 PPM.
22-7/8 (580mm)
ULTRA-LOW NOx EMISSIONS
COPPER PRIMARY HEAT EXCHANGER Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm)
OUTDOOR MODEL
Front view Bo om view
WARRANTY • 15-year limited warranty on heat exchanger in residential application. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
38
6" (152.1mm)
Gas 4/1/2" (113.7mm)
Bo om view Type
Condensate drain port 3-1/4" (82.8mm)
Model Number*
Maximum Input (BTU/H)
Hot 6-1/2" (164.6mm)
Inlet Gas Pressure
Top view Energy 13-5/16" (338.1mm)
Hot/Cold Gas Minimum Maximum in. Factor Connections Connection (EF) in. W.C. W.C.
Indoor Models 5.0
10.5
1/2" (13.3mm) 4-3/4" (121.1mm) 1-7/16" (36.8mm) 5-1/16" (129.1mm) 4-1/2" (113.7mm)
Type
Sizing Chart (Number of Showers) GAS 4-3/16" (106.1mm)
Model Number*
Cold Climate**
COLD 7-1/16" (179.2mm)
POWER VENT OR POWER DIRECT VENT DESIGN
1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) 120VAC 3-13/16" (96.1mm) Gas 4-1/8" (105.4mm)
Cold 1/2" (13.3mm) 120VAC 1-7/16" (36.8mm)
GT-140-NIH Natural 120,000
INTERNAL FREEZE PROTECTION SYSTEM
2-5/16" (58.4mm) 6-1/4" (158.5mm)
Cold 7" (178.5mm)
HOT 6-1/2" (165.3mm)
CSA 4.3
5-3/8" (137mm) 7-1/16" (180mm)
120VAC 7-3/4" (197.2mm)
22-7/8 (580mm)
Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm)
SAFETY FEATURES
ANSI Z21.10.3
3" (75.5mm) 8" (203mm)
1/2" (13.3mm) 4-3/4" (121.1mm) 3-1/16" (77mm) 5-1/16" (129.1mm) 4-1/2" (113.7mm)
OUTDOOR MODELS
• Air-Fuel Ratio (AFR) Sensor. • Exhaust & Water Temperature Safety Control. • Overheat Cut-Off Fuse.
Top view Side view 13-5/16" (338.1mm) 10-3/4" (272.4mm) 10-5/16" (262.2mm)
2-9/16" (65.8mm)
• Include a built-in temperature controller and advanced diagnostics to simplify troubleshooting. • Factory-installed Power Cord Included for Indoor Models
Condensate drain port
INDOOR MODELS
3-1/4" (82.8mm)
HOT 6-1/2" (165.3mm)
13-7/8" (352mm) 10" (254mm) 7-1/16" (180mm) 5-3/8" (137mm)
COLD 7-1/16" (179.2mm)
• Marine-grade 316L stainless steel to protect against corrosion.
ELECTRONIC IGNITION - NO PILOT LIGHT
Gas 4/1/2" (113.7mm)
1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) Gas 4-1/8" (105.4mm) Hot 6-1/2" (164.6mm) Cold 7" (178.5mm) 120VAC 7-3/4" (196.5mm)
OUTDOOR MODEL
SECONDARY HEAT EXCHANGER
• Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
Cold 1/2" (13.3mm) 120VAC 3-1/16" (77mm)
5-3/8" (137mm) 7-1/16" (180mm)
1-11/16" (42.5mm) GAS 4-3/16" (106.1mm)
• 25x better heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger.
Warm Climate***
0.93
3/4” NPT
1/2” NPT
Clearance (Inches) Top Bottom
Side Front Back
Indoor Models GT-140-NIH Natural
1.5
2
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example: GT-140-PIH) For outdoor models change “I” to “E” in the model number (example: GT-140-NEH) **Cold climate represents 70˚F temperature rise. ***Warm climate represents 50˚F temperature rise.
39
Residential Gas
Tankless Condensing High Efficiency
INDOOR MODEL
INDOOR MODEL 4" (102 mm) Female
INDOOR MODELS • Include integrated temperature controls and advanced diagnostics to simplify troubleshooting. • Include factory-installed power cords
22-1/2" (570 mm)
24-7/8" (631 mm)
23-5/8" (600 mm)
HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm)
OUTDOOR MODEL
OUTDOOR MODEL 17-3/4" (450 mm)
HOT 4-3/4" (120 mm)
7" (180 mm) Condens ate drain port 7-1/2" (189 mm) 4-1/2" (114 mm) GAS 5-7/8" (147 mm) 120 VAC 3" (77 mm)
11-1/4" (285 mm) 11" (281 mm)
17-5/8" (448 mm)
6-1/4" (159 mm) 10-3/4" (272 mm)
COLD 5/8" (17 mm)
OUTDOOR MODELS • Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condens ate drain port 7-7/8" (199 mm)
COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm)
22-1/2" (570 mm) 5-3/4" (147 mm)
• Primary heat exchanger of GT-540 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger. • Secondary heat exchanger is made of marine-grade 316L stainless steel to protect against corrosion.
10-3/4" (272mm)
GAS 5-1/8" (131 mm) 3-5/8" (92 mm) COLD 6-3/4" (172 mm) 1-1/2" (37 mm)
HEAT EXCHANGER
6-1/4" (159mm)
24-7/8" (631 mm) HOT 5-1/2" (140 mm) (600 (174 mm) mm) 12023-5/8" VAC 6-7/8"
MAXIMUM FLOW RATES UP TO 10.0 GPM
5-3/4" (147 mm)
Exhaust 2-5/8" (65 mm)
ULTRA-LOW NOX EMISSIONS • Complies with SCAQMD Rule 1146.2 NOx Emission Requirements of 14 ng/J or 20 PPM.
11-1/4" (285 mm)
4" (101 mm)
4" (102 mm) Female
Condensate drain port 7-7/8" (199 mm)
CONDENSING TECHNOLOGY PROVIDES 0.95 ENERGY FACTOR
17-3/4" (450 mm) 7" (180 mm)
HOT 4-3/4" (120 mm) 120 VAC 6-1/4" (159 mm) Drain port 6-3/4" (170 mm)
1/2" (13 mm) 120 VAC 3" (77 mm) GAS (131 mm) HOT (140 mm) Drain port 6" (152 mm)
COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm)
COMMON VENT INDOOR MODELS UP TO 8 UNITS
INTERNAL FREEZE PROTECTION SYSTEM POWER VENT OR POWER DIRECT VENT DESIGN WARRANTY
40
• 15-year limited warranty on heat exchanger in residential application. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
7-1/2" (189 mm)
GT-240-NEH Natural 160,000
5.0
GT-340-NEH Natural 180,000
5.0
GT-540-NEH Natural 199,000
5.0
Model Type 120 VAC Number* 6-1/4" (159 mm)
COLD 6-3/4" (172 mm)
• Air-Fuel Ration (AFR) Sensor. • Exhaust & Water Temperature Safety Control. • Overheat Cut-off Fuse.
HOT 4-3/4" (120 mm)
Indoor Models
Inlet Gas Pressure Energy Hot/Cold Gas Minimum Maximum in. Factor Connections Connection (EF) Condens ate drain in. port W.C. W.C.
Maximum BTU/H
10.5
0.95
17-5/8" mm) 3/4”(448 NPT
3/4” NPT
10.5
0.95
3/4” NPT
3/4” NPT
10.5
0.95
3/4” NPT
3/4” NPT
Condensate drain port 7-7/8" (199 mm)
SAFETY FEATURES
Type
GAS 5-1/8" (131 mm)
CSA 4.3
Model Number*
HOT 5-1/2" (140 mm)
ANSI Z21.10.3
• Can be used in both residential and commercial applications • Easy-Link up to 4 heaters • Multi-Link up to 20 heaters
COLD 6-3/4" (172 mm) Condens ate drain port 7-7/8" (199 mm)
120 VAC 3" (77 mm)
GT-540-NIH & GT-540-NEH
Intake 2-5/8" (68 mm)
ENERGY STAR® QUALIFIED
Sizing Chart (Number of Showers) COLDCold 5/8" (17 mm)
Climate**
Warm Climate***
Clearance (Inches) Top Bottom Side Front Back
Indoor Models GT-240-NEH
Natural
2
3
12
12
2
4
0.5
GT-340-NEH
Natural
2.5
3.5
12
12
2
4
0.5
GT-540-NEH
Natural
3
4
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example: GT-240-PIH) For outdoor models change “I” to “E” in the model number (example: GT-240-NEH) **Cold climate represents 70˚F temperature rise. ***Warm climate represents 50˚F temperature rise.
41
Residential Gas
Tankless Non-Condensing 13-3/4" (350mm) 10" (254mm)
LOW NOx EMISSIONS
HOT 5-1/4" (133mm)
1-7/8" (47mm) 120V 1-3/8" (36mm) COLD 3-1/4" (84mm) GAS 4-7/8" (124mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
OUTDOOR MODEL 13-3/4" (350mm) 13-3/4" (350mm) 10" (254mm)10" (254mm) 7-7/8" (203mm) 7-7/8" (203mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 5" (128mm) 5" (128mm)
1-5/8" (43mm)
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
• Easy-Link up to 4 units
1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 120VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm)
1-7/8" (47mm) COLD 3-1/4" (84mm)
19-3/8" (493mm)
19-3/8" (493mm)
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
1-3/8" (36mm)
FACTORY-INSTALLED POWER CORD INCLUDED FOR INDOOR MODELS GT-510-NI & GT-510-NE CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS
1-5/8" (43mm)
1-3/8" (36mm)
4-3/8" (113mm) 4-3/8" (113mm)
19-3/8" (493mm)
• Includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
4-3/8" (113mm)
1-3/4" (45mm)
19-3/8" (493mm)
INDOOR/OUTDOOR MODELS
4-3/8" (113mm)
4" (101 mm)
1-3/4" (45mm)
COPPER PRIMARY HEAT EXCHANGER • Primary heat exchanger of the 510 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger.
INDOOR MODEL
4" (101 mm) 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm)
1-3/4" (45mm)
1-5/8" (43mm)
MAXIMUM FLOW RATES UP TO 10.0 GPM
SAFETY FEATURES • Air-Fuel Ration (AFR) Sensor. • Exhaust & Water Temperature Safety Control. 510 Models
CSA 4.3
3-1/4" (84mm) COLD 3-1/4"COLD (84mm) HOT 5-1/4" (133mm) HOT 5-1/4" (133mm)
• Overheat Cut-off Fuse.
POWER VENT OR POWER DIRECT VENT DESIGN ANSI Z21.10.3
1" (26mm) 1" (26mm) 2-7/8" (71mm) COLD 2-7/8"COLD (71mm) 120VAC 3-7/8" (99mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) GAS 5-1/4" (135mm) 1-3/8" (36mm) 120V 1-3/8" 120V (36mm) HOT 6-1/2" (164mm) HOT 6-1/2" (164mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) GAS 4-7/8" (124mm) 9-1/2" (241mm)
1-7/8" (47mm) 1-7/8" (47mm)
INTERNAL FREEZE PROTECTION WARRANTY • 15-year limited warranty on heat exchanger in residential application. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
Model Number*
Type
Maximum BTU/H
Inlet Gas Pressure Minimum in. W.C.
Maximum in.W.C.
Energy Hot/Cold Factor Connections (EF)
Gas Connection
Indoor Models GT-110-NI Natural 140,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
GT-310-NI Natural 190,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
GT-510-NI Natural 199,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
Model Number*
Type
Sizing Chart (Number of Showers)
Clearance (Inches)
Cold Climate**
Warm Climate***
Top
Bottom
Side Front Back
Indoor Models GT-110-NI
Natural
1.5
2
12
12
2
4
0.5
GT-310-NI
Natural
2
3
12
12
2
4
0.5
GT-510-NI
Natural
2.5
3.5
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example: GT-110-PI). For outdoor models change “I” to “E” in the model number (example: GT-110-NE). **Cold climate represents 70˚F temperature rise. ***Warm climate represents 50˚F temperature rise.
42
43
Tankless Non-Condensing Ultra-Low NOx
Residential Gas
• Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
GT-510U CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS • Easy-Link Up To 4 Units.
1-7/8" (47 mm) HOT 4-5/8" (116 mm)
• Air-fuel ratio (AFR) Sensor.
13-3/4" (350 mm)
HOT 4-5/8" (119 mm)
10" (254 mm) 7" (180 mm)
COLD 4-7/8"3-5/8" (124 (94 mm) mm) GAS7"1-1/2" (38 mm) (203 mm)
120 VAC 1-1/2" (37 mm)
1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm)
1-7/8" (47 mm) HOT 4-5/8" (116 mm)
• Exhaust & Water Temperature Safety Control.
POWER VENT OR POWER DIRECT VENT DESIGN WARRANTY • 15-year limited warranty on heat exchanger in residential applications. • 5-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
HOT 4-5/8" (119 mm)
Model Number*
Inlet Gas Pressure
Type
COLDMaximum 4-7/8" (124 mm) Minimum GAS 1-1/2" (38 mm) BTU/H
Energy Gas 13-1/8" (334 Hot/Cold mm) Factor Connections Connection (EF)
in.W.C.
Maximum in. W.C.
GT-110U-NI Natural 140,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
GT-310U-NI Natural 190,000
5.0
10.5
0.82
3/4” NPT
3/4” NPT
5.0
10.5
0.82
3/4” NPT
3/4” NPT
Indoor Models
120 VAC 1-7/8" (49 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm)
• Overheat cut-off fuse.
INTERNAL FREEZE PROTECTION
ANSI Z21.10.3
13-1/8" (334 mm) 5-1/8" (130 mm)
5" (128 mm)
HOT 5" (127 mm)
510U Models
19-3/8" (493 mm)
OUTDOOR MODEL
• Multi-Link Up to 20 Units.
SAFETY FEATURES
1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm)
19-3/8" (493 mm)
INDOOR/OUTDOOR MODELS
1-3/8" (36 mm)
4-3/8" (113 mm)
• Primary heat exchange of the GT-510U is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger indoor and outdoor models available.
4-3/8" (113 mm)
120 VAC 1-7/8" (49 mm) 1-5/8" (43 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm)
COPPER PRIMARY HEAT EXCHANGER
∅4 (101 mm)
20-1/4" (520mm)
MAXIMUM FLOW RATES UP TO 10.0 GPM
3-5/8" (94 mm)
20-1/4" (520 mm)HOT 5" (127 mm)
• Complies with SCAQMD rule 1146.2 NOx emission requirements of 14 ng/J or 20 PPM.
INDOOR MODEL
13-3/4" (350 mm) 10" (254 mm) 7" (180 mm)
2-1/4" (58 mm)
ULTRA-LOW NOx EMISSIONS
GT-510U-NI Natural 199,000 120 VAC 1-1/2" (37 mm)
Model Number*
Type
Sizing Chart (Number of Showers) Cold Climate**
Warm Climate***
Clearance (Inches) Top Bottom Side
Front
Back
0.5
Indoor Models GT-110U-NI Natural
1.5
2
12
12
2
4
GT-310U-NI Natural
2
3
12
12
2
4
0.5
GT-510U-NI Natural
2.5
3.5
12
12
2
4
0.5
*Available in Natural Gas only For outdoor models change “I” to “E” in the model number (example: GT-110U-NE) **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise
44
45
Residential Electric
High Efficiency Hybrid Electric Heat Pump INCREASED ENERGY EFFICIENCY • Improved efficiency designed in, to ensure available hot water at the lowest possible cost • Up to a 3.24 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications
DUAL VOLTAGE CAPABLE • 208/240 VAC 60Hz capable for use in almost any residential installation.
CHOICE OF OPERATING MODES • Select from efficiency, hybrid, or electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. • Vacation mode reduces operating costs and provides freeze protection during extended absence
A
B C
E
BACKUP ELECTRIC ELEMENTS • Long-lasting 4500W backup heating elements help heat water according to environmental conditions, demand, and the chosen operating modes.
DRY FIRE PROTECTION D
• Control system ensures the tank is full of water during start up to prevent dry firing the heating elements
ELECTRONIC USER INTERFACE • User-friendly electronic interface allows easy control of temperature setting, operating mode, and communicates diagnostics
1st Hour Rating (Gal) By Mode
Energy Factor by Mode
Model Number
Gallon Capacity
• Easy to read temperature display (see back) shows temperature in °F or °C
HPHE10250H045DV
50
3.61
3.24
0.93
44.4
70
57.3
HPHE10266H045DV
66
3.44
3.17
0.92
62.5
80
78.6
• Advanced diagnostics convey error messages for service purposes. The last four error messages are saved in the control system memory.
HPHE10280H045DV
80
3.27
3.06
0.92
76.3
95
90.1
Model Number
Efficiency Hybrid Electric Efficiency Hybrid Electric
A
Dimensions in Inches B
C
D
E
Approx. Shipping Weight (lbs)
OTHER FEATURES
HPHE10250H045DV
63
22
40-5/8
3-3/4
40-1/2
196
• Ideal for basements or garage installations; the compressor transfers heat to the water while dehumidifying and cooling the ambient air.
HPHE10266H045DV
61
27
38
4
38
289
HPHE10280H045DV
69
27
46
4
46
307
Requires 30 amp breaker. Top T&P option not available on these models.
• Washable air filter is easily removed for routine cleaning.
10-YEAR LIMITED WARRANTY • For complete information, consult written warranty or americanwaterheater.com. 46
47
High Efficiency Hybrid Heat Pump
Residential Electric
INCREASED STORAGE • High capacity storage tank enables the heat pump to operate more frequently than backup heating elements. This improves energy efficiency and lowers operating costs, saving more money than lower capacity units • High capacity storage tank provides more hot water for peak demand periods
ENERGY EFFICIENCY • Up to 2.33 Energy Factor (EF) rating conserves energy and meets ENERGY STAR® qualifications.
CHOICE OF OPERATING MODES • Select from efficiency, hybrid, or electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. Vacation mode reduces operating costs and provides freeze protection during extended absence.
A
E C
BACK UP ELECTRIC ELEMENTS • Long-lasting, 240VAC incoloy heating elements, 2000W lower and 4500W upper, help heat water when in conventional electric or hybrid modes.
D
DRY FIRE PROTECTION • Control system ensures the tank is full of water during start up to prevent dry firing the heating elements
ELECTRONIC USER INTERFACE • User-friendly LCD touch-pad control, with plain English text and intuitive status icons provides easy interaction • Large LCD temperature display (see back) shows temperature in °F or °C • 3 line, 13 character backlit LCD display communicates current set point, status and operational information. • Advanced diagnostics convey error messages in plain English. The last four error messages are saved in the control system memory. • Child resistant safety lock deters unwanted access to temperature and operational settings
Model Number
Gallon Capacity
Efficiency*
Hybrid
Electric
Approx. Shipping Weight (lbs)
HPE6280H045DV
80
2.30
2.33
0.85
340
Model Number
1st Hour Rating (Gal) By Mode Efficiency
HPE6280H045DV
Energy Factor by Mode
70
Hybrid Electric 84
76
Dimensions in Inches A
B
C
D
E
82-1/2 24-1/2 55 4-1/4 56-1/3
Requires 30 amp breaker. Top T&P option not available on this model.
ACCESSORY INLET/OUTLET DUCT KITS WITH BOOSTER FAN (PART NUMBERS: 9910005000, 9910006000 & 9910057000) 6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com 48
49
High Efficiency Hybrid Electric Heat Pump
Residential Electric
INCREASED ENERGY EFFICIENCY • Improved efficiency designed in, to ensure available hot water at the lowest possible cost. • Up to a 2.75 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications.
CHOICE OF OPERATING MODES • Select from Efficiency, Hybrid, or Electric modes to match heating requirements to environmental conditions and hot water demand. Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements.
A
• Vacation mode reduces operating costs and provides freeze protection during extended absence.
BACKUP ELECTRIC ELEMENTS
B C
E
• Long-lasting 4500W backup heating elements help heat water according to environmental conditions, demand, and the chosen operating mode.
DRY FIRE PROTECTION • Control system checks to ensure the tank is full of water during start up to prevent dry firing the heating elements.
D
ELECTRONIC USER INTERFACE • User-friendly electronic interface allows easy control of temperature setting, operating mode, and communicates diagnostics. • Easy to read temperature display (see back) shows temperature in °F or °C. • Advanced diagnostics convey error messages for service purposes. The last four error messages are saved in the control system memory.
OTHER FEATURES • Ideal for basements or garage installations; the compressor transfers heat to the water while dehumidifying and cooling the ambient air. • Washable air filter is easily removed for routine cleaning.
Energy Factor by Mode
Model Number
Gallon Capacity
Efficiency
Hybrid
Electric
HPSE6250H045DV
50
2.78
2.75
0.89
HPSE6266H045DV
66
2.71
2.74
0.91
HPSE6280H045DV
80
2.71
2.72
0.92
Dimensions in Inches Model Number
Approx. Shipping Weight (lbs.)
A
B
C
D
E
HPSE6250H045DV
63
22
40-5/8
3-3/4
40-1/2
196
HPSE6266H045DV
61
27
38
4
38
285
HPSE6280H045DV
69
27
46
4
46
302
Requires 30 amp breaker. Top T&P option not available on this model.
6-YEAR LIMITED WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
50
51
Self-Cleaning
ACCESS PANEL & USER INTERFACE
ENERGY SMART
S TANDARD
VAC ATION
GRID ENABLED
F
°F/°C
Residential Electric ANODE
ELECTRONIC USER INTERFACE • Touchscreen display. ACCESS • Multiple operating modes help savePANEL money. • Energy saver and vacation modes available. DRAIN • Diagnostic feedback. VALVE • Dry fire protection. • Grid management capable, requires optional CEA-2045 Bridge module.
SMART PORT MODULE CONNECTION T&P VALVE
JUNCTION BOX
ENHANCED HEATING ELEMENTS • Dual 5500 watt elements for the fastest recovery and reliable operation. • Incoloy stainless steel elements last longer than standard copper elements.
T&P VALVE ACCESS PANEL & USER INTERFACE
ENHANCED-FLOW BRASS DRAIN VALVE CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U. S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing
ENERGY SMART
S TANDARD
VAC ATION
GRID ENABLED
F
°F/°C
ACCESS PANEL DRAIN VALVE
JU Model Number
Gallon Capacity
First Hour Rating Gallon
Energy Factor
Recovery @ 90°F Rise Gallon Per Hour
Approx. Shipping Weight (lbs)
Tall Models ES10N-40H
40
61
0.95
25
118
DESIGN-LISTED BY UNDERWRITERS LABORATORIES
ES10N-50H
50
79
0.95
25
134
ES10N-55H
55
79
0.94
25
145
• Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters.
Short Models ES10N-40R
40
56
0.95
25
109
ES10N-50R
50
58
0.95
25
161
10-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com
Model Number
Element Wattage 240V
Dimensions in Inches
Standard
Maximum
A
B
C
ES10N-40H
5500
5500
60-1/4
53-1/4
20
ES10N-50H
5500
5500
60-1/2
51-1/4
22
ES10N-55H
5500
5500
56-1/2
48-1/2
24
ES10N-40R
5500
5500
50
40-3/4
22
ES10N-50R
5500
5500
49-3/4
40-1/4
24
Tall Models
Short Models
Only available for 240V or 208V applications. Equipped as dual element only; no single element configurations available. Top T&P option not available on these models. 3/4” water connections on 8” center.
52
53
Standard
Residential Electric ENHANCED HEATING ELEMENTS • Dual 4500 watt elements for faster recovery and reliable operation.
Recovery @ 90°F Gallon First Hour Energy Approx. Shipping Rise Gallon Per Capacity Rating Gallon Factor Weight (lbs) Hour
Tall Models
• Incoloy stainless steel lower element lasts longer than standard copper elements.
E6N-30H†
30
47
0.95
21
95
E6N-40H†
40
51
0.95
21
118
HIGH ENERGY FACTORS
E6N-50HB*
50
70
0.95
21
131
E6N-50H†
50
71
0.95
21
134
E6N-55H†
55
76
0.94
21
145
E6N-30RB*
30
48
0.95
21
95
E6N-30R†
30
49
0.95
21
94
• Meets UBC, CEC and HUD National Codes.
E6N-40R†
40
55
0.95
21
109
• Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1.
E6N-50R†
50
62
0.95
21
161
19.5
N/A
N/A
21
65
E6N-30LB*
28
40
0.95
21
96
• Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
E6N-30L†
28
43
0.95
21
115
E6N-40LB*
38
46
0.95
21
118
E6N-40L†+
38
44
0.95
21
118
SELF-CLEANING DIP TUBE COREGARD™ ANODE ROD CODE COMPLIANCE
APPROVED FOR MANUFACTURED HOUSING
Short Models
Lowboy Top Connect Models E6N-20L
Model Number
Element Wattage 240V
Dimensions in Inches
Standard
Maximum
A
B
C
E6N-30H†
4500
6000
46-1/2
39-1/2
19
E6N-40H†
4500
6000
60-1/4
53-1/4
20
E6N-50HB*
4500
6000
60-1/4
51-1/4
21
E6N-50H†
4500
6000
60-1/2
51-1/4
22
• Certified at 300 PSI test pressure and 150 PSI working pressure.
E6N-55H†
4500
6000
56-1/2
48-1/2
24
• Listed according to UL 174 standards governing storage tank-type electric water heaters.
E6N-30RB*
4500
6000
39
30-1/2
20
E6N-30R†
4500
6000
39-3/4
30-1/2
22
E6N-40R†
4500
6000
50
40-3/4
22
6-YEAR LIMITED TANK AND PARTS WARRANTY
E6N-50R†
4500
6000
49-3/4
40-3/8
24
• For complete information, consult written warranty or americanwaterheater.com.
E6N-20L
4500
6000
30
21-1/4
20
E6N-30LB*
4500
6000
30
21-3/4
22
E6N-30L†
4500
6000
31-1/4
21-3/4
24
E6N-40LB*
4500
6000
31-3/4
24
24
E6N-40L†+
4500
6000
33-1/2
24
26
• All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing.
DESIGN-LISTED BY UNDERWRITERS LABORATORIES
T&P VALVE
ANODE
ACCESS PANEL
JUNCTION BOX T&P VALVE
54
Model Number
Tall Models
Short Models
Lowboy Top Connect Models
*Models ship with supplied insulation blanket. † For 10-year tank and 6-year parts limited warranty, change “6” to “10” in the model number (example: E10N-40H). +Top T&P option not available on this model. 3/4” water connections on 8” center. E6N-20L is a single element configuration only.
ANODE
JUNCTION BOX ACCESS PANEL DRAIN VALVE
T&P VALVE
55
Mobile Home
Residential Electric
APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD Standards for mobile homes/manufactured housing.
ANODE
C
JUNCTION BOX
SIDE WATER CONNECTIONS
T&P VALVE
• For ease of installation in mobile home applications.
WATER CONNECTIONS
COREGARD™ ANODE ROD • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods
T&P VALVE OUTLET
LONG-LASTING HEATING ELEMENTS • Screw-in, direct immersion, 3500W/240V or 3000W/120V heating elements for maximum efficiency.
C
E
B
A
BLUE DIAMOND® GLASS COATING ENHANCED-FLOW BRASS DRAIN VALVE • Our residential water heaters have a solid brass, tamper resistant, enhanced-flow, ball type, drain valve • Uses a standard female hose fitting that allows for fast and easy draining during maintenance.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE CODE COMPLIANCE • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
DESIGN-LISTED BY UNDERWRITERS LABORATORIES • Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY 56
• For complete information, consult written warranty or americanwaterheater.com.
INLET
DRAIN VALVE
D Model Number
Gallon Capacity
First Hour Rating Gallon
Energy Factor
Recovery @ 90°F Rise Gallon Per Hour
MHE6-30H-030D
30
42
0.95
14
MHE6-30H-035D
30
42
0.95
16
MHE6-40R-030D
40
51
0.95
14
MHE6-40R-035D
40
51
0.95
16
MHE6-30L-030D*
28
40
0.95
14
MHE6-30L-035D*
28
40
0.95
16
Model Number
Voltage
MHE6-30H-030D MHE6-30H-035D MHE6-40R-030D MHE6-40R-035D MHE6-30L-030D* MHE6-30L-035D*
120 240 120 240 120 240
Model Number MHE6-30H-030D MHE6-30H-035D MHE6-40R-030D MHE6-40R-035D MHE6-30L-030D* MHE6-30L-035D*
Wattage Upper Element Lower Element 3000 3500 3000 3500 3000 3500
Approx. Shipping Weight (lbs)
3000 3500 3000 3500 3000 3500
98 98 109 109 96 96
Dimensions in Inches A
B
C
D
E
46-3/4 46-3/4 50 50 30 30
39-1/2 39-1/2 40-3/4 40-3/4 21-3/4 21-3/4
19 19 22 22 22 22
3-7/8 3-7/8 4-3/8 4-3/8 4-1/2 4-1/2
39-5/8 39-5/8 41 41 22 22
*Models ship with supplied insulation blanket. MHE6 models have limited element options due to element size or other restrictions. Top T&P option not available on these models. ¾” water connections.
57
Residential Electric
Specialty Electric APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD Standards for mobile homes/manufactured housing.
Compact Models
Lowboy Models
E61-06U-017SV, E61-12U-015SV E61-20U-015SV, E61-19L-045D
E6N-30LS, E6N-30LBS E6N-40LS, E6N-40LBS
TABLE TOP • Features a convenient flat porcelain surface at 36” height, providing extra “counter space” wherever installed. All plumbing and electrical connections are made through the back of the water heater. This heater is equipped with a PEX cross-linked polymer dip tube.
I O
Inlet Outlet
Drain T&P
D T
Plugged Inlet Plugged Outlet
I* O*
Table Top Model
Point-Of-Use
E62-38T-045DV
E1E2.5US015V
POINT-OF-USE TABLE TOP
• Designed for low-demand, such as office lavatories or buildings with remote restrooms.
COMPACT
POINT-OF-USE
• Top-mounted plumbing connections (optional side-mounted water connections for field conversion). Designed for installation under a counter, in a crawl space or in other tight spaces.
E61-06U-017SV
6
N/A
N/A
1650
3000
CODE COMPLIANCE
E61-12U-015SV
12
N/A
N/A
1500
6000
• Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/ IESNA 90.1. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
E61-20U-015SV
19
N/A
N/A
1500
6000
E61-19L-045DV
19.9
N/A
N/A
4500 @ 240V
6000
DESIGN-LISTED BY UNDERWRITERS LABORATORIES COMPACT
• Certified at 300 PSI test pressure and 150 PSI working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com.
Model Number
Gallon Capacity
Element Wattage
First Hour Energy Rating Gallon Factor
COMPACT MODELS
Standard
Maximum
120V
LOWBOY SIDE-CONNECT MODEL
240V
240V
E6N-30LBS*
28
39
0.95
4500
6000
E6N-30LS
28
39
0.95
4500
6000
E6N-40LBS*
38
47
0.95
4500
6000
E6N-40LS
38
44
0.95
4500
6000
4500
5500
TABLE TOP MODEL
240V 38
E62-38T-045DV
45
0.88
POINT-OF-USE MODELS 2.5
E1E2.5US015V
Model Number
120V N/A
Recovery @ 90˚ F Rise Gallon Per Hour
N/A
1500 @ 120V
Dimensions in Inches A
B
C
Approx. Shipping Weight (lbs)
COMPACT MODELS E61-06U-017SV
8
15-3/8
10-3/4
14-1/4
31
E61-12U-015SV
7
22-3/4
16-1/2
16
49
E61-20U-015SV
7
25
18-1/2
18
65
E61-19L-045DV
21
31-1/4
24-1/4
16
60
LOWBOY SIDE-CONNECT MODEL E6N-30LBS*
21
30
21-3/4
22
101
E6N-30LS
21
31-1/4
21-3/4
24
115
E6N-40LBS*
21
31-3/4
24
24
118
E6N-40LS
21
33-1/2
24
26
118
21
36
25
24
150
7
13-3/4
11
13-3/4
20
TABLE TOP MODEL LOWBOY
E62-38T-045DV POINT-OF-USE MODELS E1E2.5US015V
58
*Models ship with a supplied insulation blanket.
59
In-Line, Free-Standing and Horizontal
Residential Pump Tanks
Certified to NSF/ANSI 61-G and 372
• Metal air valve • 100 PSI working pressure • Multiple head construction • Interior epoxy coating
Dimensions in Inches Model Number
Volume Connecting (Gallons) NPT Size
Overall Height A
To Center of Water Inlet
Diameter B
Weight (lbs.)
• Durable butyl rubber parabolic diaphragm
Inline and Free-Standing Series
• Positive lock retention system, eliminates loss of air and/or water leaks in the tank
APTI-2
1.9
3/4 (M)
10-3/16
-
8-1/4
5
APTI-5
4.8
3/4 (M)
14-3/4
-
11
9
• Electrostatically applied powder-coated exterior provides the ultimate protection against corrosion.
APTI-7
7.3
3/4 (M)
21-1/16
-
11
14
APT-14
14
1 (M)
24 15/16
2
15-3/8
23
APT-20
20
1 (F)
32 3/8
2
15-3/8
34
APT-26
26
1 (F)
39 9/16
2
15-3/8
43
APT-32
32
1 (F)
47 1/4
2
15-3/8
52
APT-45
45
1 1/4 (F)
36 9/16
2-1/2
22
64
• 5-year limited warranty
APT-65
65
1-1/4 (F)
48 5/8
2-1/2
22
89
APT-85
85
1-1/4 (F)
60-11/16
2-1/2
22
113
APT-86
86
1-1/4 (F)
46
2-1/2
26
116
APT-119
119
1-1/4 (F)
61-5/16
2-1/2
26
161
Horizontal Series
Length
APTH-7
7.3
3/4 (M)
12-7/8
-
11
16
APTH-14
14
1 (M)
18-1/4
-
15-3/8
26
APTH-20
20
1 (M)
18-1/4
-
15-3/8
36
Note: M- Male connection F- Female connection All models 38 PSI pre-charge
60
61
Potable and In-Line Hydronic
Residential Expansion Tanks
Model Number
Maximum (PSIG) Working Pressure
Tank Volume (Gallons)
Maximum Accepted Volume (Gallons) 20 PSI
40 PSI
60 PSI
Potable Expansion Tanks - 5-Year Limited Warranty
Certified to NSF/ANSI 61-G and 372
When used in potable applications
• Expansion Tanks - available for hydonic or potable applications
AET-2
150
1.96
1.53
1.27
1.03
AET-5
150
4.55
3.75
3.05
2.19
AET-10
150
9.25
7.80
6.55
5.25
Potable Expansion Tanks - 1-Year Limited Warranty TW-5
150
2.10
1.53
1.27
1.03
TW-12
150
4.40
3.75
3.05
2.19
Hydronic Expansion Tanks - 1-Year Limited Warranty
• Drawn steel construction
AEH-2
100
1.96
1.53
N/A
N/A
• Tough butyl rubber parabolic diaphragm
AEH-5
100
4.55
3.75
N/A
N/A
• IAPMO approved
AEH-7
100
7.30
4.60
N/A
N/A
• Max. working pressure • 150 PSI for potable water expansion tanks • 100 PSI for hydonic expansion tanks
Model Number
Connection NPT Size
Dimensions in Inches A Overall Height
B Diameter
Weight (lbs)
• 5-Year limited warranty on potable AET expansion tanks
Potable Expansion Tanks - 5-Year Limited Warranty
• 1-Year limited warranty on potable TW Series expansion tanks
AET-2
3/4
10-3/16
8-1/4
• 1-Year limited warranty on hydonic expansion tanks
AET-5
3/4
14-3/4
11
9
AET-10
3/4
15-1/2
15-3/8
18
5
Potable Expansion Tanks - 1-Year Limited Warranty TW-5
3/4
10-3/16
8-1/4
5
TW-12
3/4
14-3/4
11
9 5
Hydronic Expansion Tanks - 1-Year Limited Warranty AEH-2
1/2
10-3/16
8-1/4
AEH-5
1/2
14-3/4
11
8
AEH-7
1/2
21-1/16
11
14
All AET and TW Series models 38 PSI pre-charge All AEH models 12 PSI pre-charge
62
63
Non-Dampered
F
K
HOT WATER OUTLET
Commercial Gas
K
COLD WATER INLET
TOP VIEW
J
GLASSLINED TANK
H TEMPERATURE AND PRESSURE RELIEF VALVE
• Maximizes tank life • Fully Automatic Controls with Safety Shutoff
D
• Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for 180°F sanitizing A
DRAIN VALVE
B
DRAIN VALVE
FOAM INSULATION
CL
CL
ANODE ROD
L
GAS INLET
HEAVY GAUGE STEEL JACKET • Finished with baked enamel over bonderized undercoat
C
COLD
HOT
G
F
K
K
HOT WATER OUTLET
COLD WATER INLET
E
TO
J
• Saves fuel, helps reduce standby heat M loss
TEMPERATURE AND PRESSURE RELIEF VALVE
LOW NOX • Complies with Texas and other Districts Requirements for NOx Emissions less than 40 ng/J
D
EASY-TO-INSTALL • Completely factory-assembled. Only gas, water and vent connections need to be made. All connections are located in front and top of heaters for ease of installation and service.
HOT
G B
DRAIN VALVE
DRAIN VALVE
GA
A CL
CL
3-YEAR LIMITED TANK/1-YEAR LIMITED PARTS WARRANTY
E M
• For complete warranty information, consult written warranty or americanwaterheater.com Model Number
Gallon Capacity
Input Rating BTU/HR
CG32-75T75-4NV CG32-100T77-4NOV
74 98
75,100 75,100
Model Number
Recovery Approx. Shipping Capacity @ Weight (lbs) 100°F Rise 73 73
275 350
Dimensions in Inches A
B
C
D
E
F
CG32-75T75-4NV
61-1/8
58-1/2
29-11/16
26-1/2
15-3/16
4
CG32-100T77-4NOV
68-5/8
66-1/2
30-15/16
27-3/4
15-3/16
4
Model Number CG32-75T75-4NV CG32-100T77-4NOV
Dimensions in Inches G
H
J
K
L
M
14-1/2 15-3/4
16 16
1-1/4 1-1/4
1 1-1/4
1/2 1/2
11-15/16 11-15/16
NSF leg kit 9006645005. Specify when ordering propane (LP) gas.
64
65
Polaris® High-Efficiency
Commercial Gas
SEALED COMBUSTION WITH WOVEN FIBER PREMIX BURNER • Metal fiber burner is designed for clean combustion in high-intensity blue flame mode. Manufactured of refractory steel that resists corrosion. Excellent resistance to thermal and mechanical shock, even at extreme temperatures. Uniform combustion provides excellent heat transfer. Meets Low NOx requirements for Texas and other air quality districts requiring 40 ng/J. • 95+% thermal Efficiency.
WHISPER QUIET OPERATION • Ultra quiet blower and burner which minimizes noise. • Requires 120 volt 60Hz power supply. • Draws less than 5 Amps.
POWER/DIRECT VENT USING 2” OR 3” PLASTIC PIPE • Direct vents up to 120’ Schedule 40 PVC, Schedule 40 or 80 CPVC or DWV pipe either thru-the-wall or thru-the-roof. • Optional concentric vent kit available for use thru-the-roof or thru-the-wall.
“PLUG AND PLAY” TECHNOLOGY • No special adjustments are required at initial start up. • Connect air inlet, exhaust outlet, water, electricity and gas, set the temperature and the system functions properly.
Model Number
Gallon Capacity
MBTU Input
GPH Recovery 100°F Rise
Thermal Efficiency
Approx. Shipping Weight (lbs)
PGC3 34-130-2NV
34
130
151
96
150
PGC3 34-150-2NV
34
150
173
95
150
PGC3 50-130-2NV
50
130
150
95
176
PGC3 50-150-2NV
50
150
173
95
176
PGC3 50-175-3NV
50
175
204
95
180
PGC3 50-199-3NV
50
199
232
95
180
Dimensions in Inches Model Number
A
B
Vent Connection
C
D
E
F
PG3 34-100-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG3 34-130-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG3 34-150-2NV
48-1/2
22
2 or 3
15-3/4
40-1/2
41
6-1/8
PG3 50-130-2NV
62-1/2
22
2 or 3
15-3/4
54-1/2
55
6-1/8
PG3 50-150-2NV
62-1/2
22
2 or 3
15-3/4
54-1/2
55
6-1/8
PG3 50-175-3NV
63-3/4
22
3
15-3/4
55-3/4 56-1/4
6-1/8
PG3 50-199-3NV
63-3/4
22
3
15-3/4
55-3/4 56-1/4
6-1/8
Model meets Low-NOx emission requirements of less than 40 ng/J. For propane gas, change “N” to “P” in the suffix of the model number. Example: PG3 34-150-2PV For multi-family/commercial installation a tempering valve (Part Number 10088754) is strongly recommended to be installed in all domestic hot water lines. Meets NSF standard when installed with stand kit.
66
67
Commercial Gas
High Efficiency HCG Series UP TO 98% EFFICIENT Gallon Capacity
Input BTU/HR
Approx. Shipping Weight (lbs) Std
Approx. Shipping Weight (lbs) ASME
HCG3-60T120-3N
60
120,000
460
490
HCG3-100T150-3N
100
150,000
523
553
• Provides detailed water heater status information
HCG3-100T199-3N
100
199,900
523
553
HCG3-100T250-3N
100
250,000
523
553
• Precise temperature control adjustable from 90 to 180 degrees
HCG3-119T300-4N
119
300,000
855
855
HCG3-119T400-4N
119
399,000
855
855
• Built-in diagnostics
HCG3-119T500-4N
119
499,000
855
855
• Run history information
Concentric vent kit for (A)HCG3-60T120 through (A)HCG3-100T250 models (part number 100111100). Concentric vent kit for (A)HCG3-199T300 through (A)HCG3-199T500. Optional Condensate Neutralization Kits available. Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. Models are certified from sea level to 10,100 ft. elevation.
INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY • Exclusive American designed control system
• Direct spark ignition
SUBMERGED COMBUSTION CHAMBER WITH HELICAL HEAT EXCHANGER COIL • Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber
Model Number
Dimensions and line drawing on the following pages.
• Spiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize efficiency of heat transfer to water in tank • Spiral heat exchanger reduces lime scale from forming on water-side surfaces, which maintains energy efficiency over time
POWER ANODES STANDARD ON ALL MODELS • Provides long-lasting tank protection in varying water condition • Powered anodes are non-sacrificial • Automatically adjusts output needed to properly protect the tank
3-YEAR LIMITED TANK AND 1-YEAR LIMITED PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com
68
69
High Efficiency HCG Series FRONT
T
T& PV AL VE
C LE AN
O
U T
Commercial Gas
US HA EX
IN DRA E VALV
(continued)
18° 42°
30° 45°
* Center line of water outlet on top of the water heaters is approximately 7 inches from the front edge of the water heater.
T & P VALVE
FRONT T&P
TOP VIEW
VENT CONNECTION 3 INCH PVC (exhaust elbow)
ALL MODELS
90° E
1 1/2” NPT WATER INLET
AIR
3/4" NPT RECIRC RETURN
AK INT
4" EXHAUST VENT CONNECTION
J
G
A
1½" NPT WATER OUTLET
A SUPPLY GAS CONNECTION
20° 70°
3/4" NPT DRAIN
26°
3/4” NPT DRAIN
C
CLEANOUT
D
S
GA
CLEANOUT
E
J
INT AKE
G
C
1 1/2" NPT WATER OUTLET
1 1/2" NPT WATER INLET
TOP
U T
FRONT
O AN C LE
T& PV AL VE
4" PVC AIR INTAKE GAS CONNECTION
1 1/2" SUPPLY GAS CONNECTION
T
N DRAI E VALV
18°
WATER OUTLET HEIGHT
42°
30° 45°
45°
* Center line of water outlet on top of the water heaters is approximately 7 inches from the front edge of the water heater.
18° 30°
42°
T US HA EX
WATER OUTLET HEIGHT
US HA EX
INTAKE AIR CONNECTION 3 INCH PVC
BACK
GAS
LOWER TEMPERATURE PROBE
FRONT
E
DRA IN
B 3/4” NPT RECIRCULATION RETURN
CL EA NO UT T& P
D
FRONT BACK
E T & P VALVE
I
F
FRONT
F
H
D
B LOWER TEMPERATURE PROBE
CLEANOUT
H
B E
3/4” NPT RECIRCULATION RETURN
VENT CONNECTION 3 INCH PVC (exhaust elbow)
1 1/2” NPT WATER INLET 3/4” NPT DRAIN
C
J
G A
Model Number
Dimensions in Inches A
B
HCG3-60T120-3N
3
HCG3-100T150-3N HCG3-100T199-3N HCG3-100T250-3N
I
SUPPLY GAS CONNECTION
C
D
27.75
6.3
35
3
27.75
6.3
3
27.75
6.3
3
27.75
6.3
INTAKE AIR CONNECTION 3 INCH PVC
E
56.38
WATER OUTLET HEIGHT
Model Number
Dimensions in Inches A
B
C
D
E
55.5
HCG3-119T300-4N
4.75
33.12
4.75
52
75.75
76
HCG3-119T400-4N
4.75
33.12
4.75
52
75.75
56.38
76
HCG3-119T500-4N
4.75
33.12
4.75
52
75.75
56.38
76
F
G
BACK
E
Model Number
Dimensions in Inches I
H
F
Model Number
Dimensions in Inches
F
G
H
I
J
H
I
J
HCG3-60T120-3N
53.5
11.25
42.25
48.5
18.25
HCG3-119T300-4N
73.75
12.75
63.13
69.25
23
HCG3-100T150-3N
75.75
11.25
64
70
18.25
HCG3-119T400-4N
73.75
12.75
63.13
69.25
23
HCG3-100T199-3N
75.75
11.25
64
70
18.25
HCG3-119T500-4N
73.75
12.75
63.13
69.25
23
HCG3-100T250-3N
75.75
11.25
64
70
18.25
Concentric vent kit for (A)HCG3-60T120 through (A)HCG3-100T250 models (part number 100111100). Concentric vent kit for (A)HCG3-199T300 through (A)HCG3-199T500. Optional Condensate Neutralization Kits available. Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. (Example: AHCG3-60T120-3N). Models are certified from sea level to 10,100 ft. elevation.
Concentric vent kit for (A)HCG3-60T120 through (A)HCG3-100T250 models (part number 100111100). Concentric vent kit for (A)HCG3-199T300 through (A)HCG3-199T500. Optional Condensate Neutralization Kits available. Electrical characteristics- 120V-60 Hz A.C., 5.0A. “A” in the model number represents ASME construction. (Example: AHCG3-60T120-3N). Models are certified from sea level to 10,100 ft. elevation.
70
71
Heavy-Duty BCG3 Series
THE ELIMIATOR™ SELFCLEANING SYSTEM • Designed to significantly reduce or eliminate sediment build-up inside the tank • Reduced sediment build-up maintains rated thermal efficiency and reduces water heating costs • Self-cleaning system maximizes tank life
FACTORY-INSTALLED DRAFT DIVERTER AND AUTOMATIC FLUE DAMPER (MODELS BCG370T1205N THRU BCG3-100T390-8N) • Low-profile draft diverter helps for installation in tight spaces • Automatic motorized flue damper helps minimize standby heat loss • BCG3-86T500-8N features induced draft design and no damper
Commercial Gas
Model Number BCG3-70T120-5N * BCG3-80T150-6N BCG3-80T180-6N BCG3-80T199-6N BCG3-100T199-6N (A)BCG3-100T200-6N (A)BCG3-100T250-8N∆ (A)BCG3-65T250-8N∆ (A)BCG3-100T275-8N∆ (A)BCG3-65T300-8N (A)BCG3-85T360-8N (A)BCG3-100T390-8N (A)BCG3-85T500-8N
Approx. Approx. GPH Gallon BTU Input Shipping Shipping Recovery @ Capacity Natural Gas Weight Weight 100°F Rise (lbs) (lbs) ASME 71 81 81 81 100 100 100 65 100 65 85 100 85
120,000 154,000 180,000 199,000 199,000 199,000 250,000 251,000 275,000 305,000 365,000 390,000 500,000
116 149 175 193 193 193 242 243 267 296 354 378 485
400 470 470 470 603 630 630 750 630 750 725 760 745
725 725 862 725 862 833 874 857
For propane (LP) gas models, change “N” to “P” in the suffix of the model number. *BCG3-70T120-5N is shipped with 6” x 5” flue outlet damper. Standard models certified from sea level to 2,000 ft. elevation. Specify high altitude when ordering for use in high elevations. BCG3-85T500-8N features induced draft design and no damper. ∆ 6” x 8” vent reducer is provided with each unit. Certified for both 6” or 8” venting.
THREE WATER CONNECTION OPTIONS FOR ADDED FLEXIBILITY • Hot and cold water connections can be made through front, top or rear of unit • Eliminator system operates when cold water is connected through the front
3-YEAR LIMITED TANK AND 1-YEAR LIMITED PARTS WARRANTY • For complete warranty information, consult written warranty or go to americanwaterheater.com
72
73
Heavy-Duty BCG3 Series
Commercial Gas
INDUCED Model DRAFT Number MOTOR B
C
Models 70T120 thru 85T390
Dimensions in Inches A
B
Model Number
I
1" NPT RELIEF VALVE OPENING TOP OUTLET
TOP INLET
OUTLET CONNECTION SPREAD C INLET
D
A
Model 85T500
BCG3-70T120-5N * BCG3-80T150-6N BCG3-80T180-6N BCG3-80T199-6N BCG3-100T199-6N (A)BCG3-100T200-6N (A)BCG3-100T250-8N∆ (A)BCG3-65T250-8N∆ (A)BCG3-100T275-8N∆ (A)BCG3-65T300-8N (A)BCG3-85T360-8N (A)BCG3-100T390-8N (A)BCG3-85T500-8N
D 50-7/8 57-7/8 53-5/8 53-5/8 TOP INLET 61-5/8 61-5/8 55-7/8 57-1/4 55-7/8 57-1/4 62-1/2 58-1/4 67-1/2
E 19-11/16 19-11/16 20-1/2 20-1/2 20-1/2 20-1/2 19-3/4 20 19-3/4 20 22-1/2 26-3/4 27-1/6
Dimensions in Inches
1" CLEARANCE
INDUCED DRAFT MOTOR B
C
I BCG3-70T120-5N * 69-3/4 4-1/4 59-1/2 1" NPT BCG3-80T150-6NRELIEF 73 4-1/4 66-1/2 VALVE BCG3-80T180-6NOPENING 67-1/2 4-1/2 62 BCG3-80T199-6N 67-1/2 4-1/2 62 TOP BCG3-100T199-6N 75OUTLET 4-1/2 70 OUTLET (A)BCG3-100T200-6N 72 4-1/2 70 (A)BCG3-100T250-8N∆ 72 4-1/2 65-1/8 CONNECTION (A)BCG3-65T250-8N∆ 75 4-1/2 65-3/4 SPREAD (A)BCG3-100T275-8N∆ 72 4-1/2 65-1/8 (A)BCG3-65T300-8ND 4-1/2 65-3/4 A 75 INLET (A)BCG3-85T360-8N 79-1/2 4-1/2 70-1/4 Model 85T500 (A)BCG3-100T390-8N 75-1/2 4-1/2 67-1/2 (A)BCG3-85T500-8N 81-1/2 17-1/2 77-1/4
F
G
H
I
J
19 19 21 21 21 21 23 N/A 23 N/A 23 23 21
1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 1
51-7/8 59 54-5/8 62-5/8 61-1/2 54-5/8 56-3/8 56-3/8 58-3/4 58-3/4 63 59 67-1/2
6 6 6 6 6 6 8 8 8 8 8 8 8
27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 30-1/4 30-1/4 27-3/4 30-1/4 27-3/4 27-3/4 30-1/4 27-3/4
For propane (LP) gas models, change “N” to “P” in the suffix of the model number. Example: (BCG3-70T120-5P). Low-NOx available on natural gas models only. *BCG3-70T120-5N is shipped with 6” x 5” flue outlet damper. Standard models certified from sea level to 2,000 ft. elevation. Specify high altitude when ordering for use in high elevations. BCG3-85T500-8N features induced draft design and no damper. ∆ 6” x 8” vent reducer is provided with each unit. Certified for both 6” or 8” venting.
1" CLEARANCE
74
75
Ultra-Low NOx BCL Series Heavy Duty
80% THERMAL EFFICIENCY MEANS LOWER OPERATING COSTS
Commercial Gas
Model Number
Gallon Capacity
Input BTU/HR
Recovery Capacity GPH @ 100°F Rise
FAN ASSISTED COMBUSTION
BCL3-80T120-6NOX*
81
120,000
115
• The blower is built into the low NOx burner assembly
BCL3-80T154-6NOX*
81
154,000
148
BCL3-80T180-6NOX*
81
180,000
173
• Complies with California SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar NOx emission requirements of 14 ng/J or 20 ppm
BCL3-80T199-6NOX
81
199,000
191
BCL3-100T199-6NOX
100
199,000
191
ABCL3-100T250-6NOX
100
250,000
240
ABCL3-100T275-6NOX
100
275,000
264
• Complies with Texas Low NOx rules.
ABCL3-86T310-6NOX*
86
310,000
298
ABCL3-86T366-6NOX*
86
366,000
352
ABCL3-86T390-6NOX*
86
390,000
375
AIR-FLAPPER • A stainless steel air flapper is used inside the premix system to replace externally mounted flue damper to minimize the standby heat loss and to minimize the overall heater height
Electrical characteristics-120V-60 Hz A.C., 5.0 A. (A) before the model number designates ASME construction. Leg kits for UL sanitation to meet NSF-5 (increases overall height by 4”). Available in natural gas only.
METAL VENTING • Rated Category I Appliance. Uses standard double wall-type "B" vent. • Can be commonly vented with other Category I Appliances • Vent connects directly to the vent connector outlet • An excellent choice for retrofit and upgrade installations
3-YEAR LIMITED TANK/1-YEAR LIMITED PARTS WARRANTY • For complete information, consult written warranty or americanwaterheater.com
76
77
Ultra-Low NOx BCL Series Heavy Duty
Commercial Gas
ROUGH IN DIMENSIONS: MASTER-FIT BTL 199 ULN
K
F TOP OUTLET 1 1/2 NPT
Model Number
TOP INLET 1 1/2 NPT
AC B
H DH
B
C
D
E
F
BCL3-120, 154, 180, 198
63-3/4
37
65
52-3/4
20-3/4
21
BCL3-199, 250(A), 275(A)
71-3/4
37
73
60-3/4
20-1/2
21
BCL3-310(A), 366(A), 390(A L
71-3/4
37
73
60-3/4
20-1/2
21
Model Number BCL3-120, 154, 180, 198
E
TOP VIEW
BCL3-199, 250(A), 275(A)
DIMENSIONS: MASTER-FIT BTL 199 ROUGH ULN IN DIMENSIONS: MASTER-FIT BTL 199 ULN I
BACK VIEW
F
F
OP OUTLET 1 1/2 NPT
TOP INLET 1 1/2 NPT
Dimensions in Inches A
BCL3-310(A), 366(A), 390(A)
Dimensions in Inches G 3/4 NPT 3/4 NPT 3/4 NPT
H
I
J
53
6
27-3/4
61
6
27-3/4
61
6
27-3/4
K
L
1-1/2 NPT 1-1/2 NPT 1-1/2 NPT
1-1/2 NPT 1-1/2 NPT 1-1/2 NPT
Electrical characteristics-120V-60 Hz A.C., 5.0 A. (A) before the model number designates ASME construction. Leg kits for UL sanitation to meet NSF-5 (increases overall height by 4”). Available in natural gas only.
K
K
TOP OUTLET 1 1/2 NPT
TOP INLET 1 1/2 NPT
AC B
G
L
B
L
E
TOP VIEW J
FRONT VIEW
78
H DH
TOP VIEW
BACK VIEW
BACK VIEW
79
Commercial Gas
Ultra-Low NOx Single Flue K HOT WATER OUTLET
K COLD WATER INLET
F
CODE COMPLIANCE • The Ultra-Low NOx atmospheric vent J commercial gas water heater which meets the thermal efficiency and standby loss requirements of the U.S.DRAIN Department of VALVE Energy and Current Edition ASHRAE/IESNA 90.1.
TOP VIEW H
TEMPERATURE AND PRESSURE RELIEF VALVE D
FULLY AUTOMATIC CONTROLS WITH SAFETY SHUTOFF A
• Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for 180˚F E sanitizing. M
C
COLD
HOT G B
DRAIN VALVE
K HOT WATER OUTLET
L GAS INLET
HEAVY GAUGE STEEL JACKET
K COLD WATER INLET
F
J
• Finished with baked enamel over bonderized FRONT VIEW undercoat.
TEMPE AND PR RELIEF
DRAIN VALVE
FOAM INSULATION
D
• Saves fuel, helps reduce standby heat loss.
G B
ULTRA-LOW NOx EMISSIONS • Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar requirements of 14 ng/J or 20 ppm.
A
DRA
• Complies with Texas Low NOx requirements. E
EASY-TO-INSTALL
M
• Completely factory-assembled. Only gas, water and vent connections need to be made. • All connections are located in front and top of the heater for ease-of-installation and service.
3-YEAR LIMITED TANK AND 1-YEAR LIMITED PARTS WARRANTY • For complete warranty information, consult written warranty or go to americanwaterheater.com
FRONT VIEW
Model Number
Gallon Capacity
BTU Input Natural Gas
Recovery Capacity GPH @ 100°F Rise
Approx. Shipping Weight (lbs)
BCN3-75T75-NOV** BCN3-100T75-NOV*
74 98
75,100 75,100
73 74
285 350
Model Number BCN3-75T75-NOV** BCN3-100T75-NOV*
Model Number
Dimensions in Inches A
B
C
D
E
62-1/16 70-1/2
58 66-1/2
29-1/2 30-15/16
25-1/4 27-3/4
15-7/8 15-3/16
Dimensions in Inches F
G
H
J
K
L
M
BCN3-75T75-NOV**
4
15-1/4
16
2
1
1/2
12-1/2
BCN3-100T75-NOV*
4
15-1/4
16
1-1/4
1-1/4
1/2
11-15/16
Natural gas only. *Recovery rating based on 81% thermal efficiency **Recovery rating based on 80% thermal efficiency
80
81
Commercial Gas
Tankless Non-Condensing 13-3/4" (350mm) 10" (254mm)
FACTORY-INSTALLED POWER CORD INCLUDED FOR INDOOR MODELS
HOT 5-1/4" (133mm)
1-7/8" (47mm) 120V 1-3/8" (36mm) COLD 3-1/4" (84mm) GAS 4-7/8" (124mm)
120V 1-3/8" (36mm)
HOT 5-1/4" (133mm)
GAS 4-7/8" (124mm)
OUTDOOR MODEL 13-3/4" (350mm) 13-3/4" (350mm) 10" (254mm)10" (254mm) 7-7/8" (203mm) 7-7/8" (203mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 5" (128mm) 5" (128mm)
1-5/8" (43mm)
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
• Easy-Link up to 4 units
1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 120VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 120VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm)
1-7/8" (47mm) COLD 3-1/4" (84mm)
19-3/8" (493mm)
19-3/8" (493mm)
20-1/4" (520mm)
21-3/8" (544mm)
20-1/4" (520mm)
21-3/8" (544mm)
1-3/8" (36mm)
LOW NOx EMISSIONS GT-510 CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS
1-5/8" (43mm)
1-3/8" (36mm)
4-3/8" (113mm) 4-3/8" (113mm)
19-3/8" (493mm)
• Includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
4-3/8" (113mm)
1-3/4" (45mm)
19-3/8" (493mm)
INDOOR/OUTDOOR MODELS
4-3/8" (113mm)
4" (101 mm)
1-3/4" (45mm)
COPPER PRIMARY HEAT EXCHANGER • Primary heat exchanger of the 510 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger.
INDOOR MODEL
4" (101 mm) 13-3/4" (350mm) 10" (254mm) 1-3/4" (45mm)
1-3/4" (45mm)
1-5/8" (43mm)
MAXIMUM FLOW RATES UP TO 10.0 GPM
SAFETY FEATURES • Air-Fuel Ration (AFR) Sensor. • Exhaust & Water Temperature Safety Control. 510 Models
• Overheat Cut-off Fuse.
1" (26mm) 1" (26mm) 2-7/8" (71mm) COLD 2-7/8"COLD (71mm) 120VAC 3-7/8" (99mm) 120VAC 3-7/8" (99mm) GAS 5-1/4" (135mm) GAS 5-1/4" (135mm) 1-3/8" (36mm) 120V 1-3/8" 120V (36mm) HOT 6-1/2" (164mm) HOT 6-1/2" (164mm) GAS 4-7/8" (124mm) 9-1/2" (241mm) GAS 4-7/8" (124mm) 9-1/2" (241mm)
1-7/8" (47mm) 1-7/8" (47mm) 3-1/4" (84mm) COLD 3-1/4"COLD (84mm) HOT 5-1/4" (133mm) HOT 5-1/4" (133mm)
INTERNAL FREEZE PROTECTION
ANSI Z21.10.3
CSA 4.3
POWER VENT OR DIRECT VENT DESIGN WARRANTY • 15-year limited warranty on heat exchanger in residential application. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
Model Number*
Type
Maximum BTU/H
Inlet Gas Pressure Minimum in. W.C.
Maximum in.W.C.
5.0
10.5
Energy Hot/Cold Factor Connections (EF)
Gas Connection
Indoor Models GT-510-NI Natural 199,000
Model Number*
Type
0.82
Sizing Chart (Number of Showers)
3/4” NPT
3/4” NPT
Clearance (Inches)
Cold Climate**
Warm Climate***
Top
Bottom
2.5
3.5
12
12
Side Front Back
Indoor Models GT-510-NI
Natural
2
4
0.5
*For propane models, change “N” to “P” in the model number (example: GT-510-PI). For outdoor models change “I” to “E” in the model number (example GT-510-NE). **Cold climate represents 70˚F temperature rise. ***Warm climate represents 50˚F temperature rise
82
83
Tankless Non-Condensing Ultra-Low NOx
Commercial Gas
• Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
GT-510U CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS • Easy-Link Up To 4 Units.
1-7/8" (47 mm) HOT 4-5/8" (116 mm)
19-3/8" (493 mm)
OUTDOOR MODEL 13-3/4" (350 mm)
HOT 4-5/8" (119 mm)
10" (254 mm) 7" (180 mm)
COLD 4-7/8"3-5/8" (124 (94 mm) mm) GAS7"1-1/2" (38 mm) (203 mm)
13-1/8" (334 mm) 5-1/8" (130 mm)
5" (128 mm)
120 VAC 1-1/2" (37 mm)
• Multi-Link Up to 20 Units.
SAFETY FEATURES
1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm)
19-3/8" (493 mm)
INDOOR/OUTDOOR MODELS
1-3/8" (36 mm)
4-3/8" (113 mm)
• Primary heat exchange of the GT-510U is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker and reducing pressure drop across the heat exchanger indoor and outdoor models available.
4-3/8" (113 mm)
120 VAC 1-7/8" (49 mm) 1-5/8" (43 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm)
COPPER PRIMARY HEAT EXCHANGER
∅4 (101 mm)
20-1/4" (520mm)
MAXIMUM FLOW RATES UP TO 10.0 GPM
3-5/8" (94 mm)
20-1/4" (520 mm)HOT 5" (127 mm)
• Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM.
INDOOR MODEL
13-3/4" (350 mm) 10" (254 mm) 7" (180 mm)
2-1/4" (58 mm)
ULTRA-LOW NOx EMISSIONS
1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm)
120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm)
1-7/8" (47 mm) HOT 4-5/8" (116 mm)
• Air-fuel ratio (AFR) sensor. • Exhaust & water temperature safety control. • Overheat cut-off fuse. HOT 4-5/8" (119 mm)
COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm)
POWER VENT OR POWER DIRECT VENT DESIGN WARRANTY • 15-year limited warranty on heat exchanger in residential applications. • 5-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
Model Number*
Type
Maximum BTU/H
13-1/8" (334 mm)
Inlet Gas Pressure Minimum in.W.C.
Maximum in. W.C.
Energy Hot/Cold Gas Factor Connections Connection (EF)
Indoor Models 120 VAC 1-7/8" (49 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm)
ANSI Z21.10.3
HOT 5" (127 mm)
INTERNAL FREEZE PROTECTION
GT-510U-NI Natural 199,000 120 VAC 1-1/2" (37 mm)
Model Number*
Type
5.0
10.5
Sizing Chart (Number of Showers) Cold Climate**
Warm Climate***
2.5
3.5
0.82
3/4” NPT
3/4” NPT
Clearance (Inches) Top Bottom Side
Front
Back
4
0.5
Indoor Models GT-510U-NI Natural
12
12
2
*For propane models, change “N” to “P” in the model number (example: GT-510U-PI). For outdoor models change “I” to “E” in the model number (example: GT-510U-NE) **Cold climate represents 70°F temperature rise ***Warm climate represents 50°F temperature rise
84
85
Commercial Gas
Tankless Condensing High Efficiency
INDOOR MODEL
INDOOR MODEL 4" (102 mm) Female
INDOOR MODELS • Include integrated temperature controls and advanced diagnostics to simplify troubleshooting. • Include factory-installed power cords
22-1/2" (570 mm)
24-7/8" (631 mm)
23-5/8" (600 mm)
HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm)
OUTDOOR MODEL
OUTDOOR MODEL 17-3/4" (450 mm)
HOT 4-3/4" (120 mm)
7" (180 mm) Condens ate drain port 7-1/2" (189 mm) 4-1/2" (114 mm) GAS 5-7/8" (147 mm) 120 VAC 3" (77 mm)
11-1/4" (285 mm) 11" (281 mm)
17-5/8" (448 mm)
6-1/4" (159 mm) 10-3/4" (272 mm)
COLD 5/8" (17 mm)
OUTDOOR MODELS • Include a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting.
1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condens ate drain port 7-7/8" (199 mm)
COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm)
22-1/2" (570 mm) 5-3/4" (147 mm)
MAXIMUM FLOW RATES UP TO 10.0 GPM
10-3/4" (272mm)
GAS 5-1/8" (131 mm) 3-5/8" (92 mm) COLD 6-3/4" (172 mm) 1-1/2" (37 mm)
• Primary heat exchanger of GT-540 is constructed of a commercial-grade copper that is more resilient to erosion. Copper is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger. • Secondary heat exchanger is made of marine-grade 316L stainless steel to protect against corrosion.
6-1/4" (159mm)
24-7/8" (631 mm) HOT 5-1/2" (140 mm) (600 (174 mm) mm) 12023-5/8" VAC 6-7/8"
HEAT EXCHANGER
5-3/4" (147 mm)
Exhaust 2-5/8" (65 mm)
ULTRA-LOW NOx EMISSIONS • Complies with SCAQMD Rule 1146.2 NOx emission requirements of 14 ng/J or 20 PPM.
11-1/4" (285 mm)
4" (101 mm)
4" (102 mm) Female
Condensate drain port 7-7/8" (199 mm)
CONDENSING TECHNOLOGY PROVIDES 0.95 ENERGY FACTOR
17-3/4" (450 mm) 7" (180 mm)
HOT 4-3/4" (120 mm) 120 VAC 6-1/4" (159 mm) Drain port 6-3/4" (170 mm)
1/2" (13 mm) 120 VAC 3" (77 mm) GAS (131 mm) HOT (140 mm) Drain port 6" (152 mm)
COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condens ate drain port 7-1/2" (189 mm)
COLD 6-3/4" (172 mm) Condens ate drain port 7-7/8" (199 mm)
COMMON VENT INDOOR MODELS UP TO 8 UNITS
SAFETY FEATURES • Air-Fuel Ration (AFR) Sensor. • Exhaust & Water Temperature Safety Control. • Overheat Cut-off Fuse.
INTERNAL FREEZE PROTECTION SYSTEM POWER VENT OR POWER DIRECT VENT DESIGN WARRANTY
86
• 15-year limited warranty on heat exchanger in residential application. • 10-year limited warranty on heat exchanger in commercial applications. • 5-year limited warranty on all parts.
Condens ate drainInlet port Gas Pressure Energy Maximum Hot/Cold Gas 7-1/2" (189 mm) Minimum Maximum in. Factor Connections Connection BTU/H (EF) in. W.C. W.C. 17-5/8" (448 mm)
GT-540-NEH Natural 199,000
Model Type 120 VAC Number* 6-1/4" (159 mm)
5.0
COLD 6-3/4" (172 mm)
Indoor Models
Type
Condensate drain port 7-7/8" (199 mm)
• Easy-Link up to 4 units. • Multi-Link up to 20 units.
HOT 4-3/4" (120 mm)
GAS 5-1/8" (131 mm)
Model Number*
HOT 5-1/2" (140 mm)
CSA 4.3
CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS
120 VAC 3" (77 mm)
ANSI Z21.10.3
Intake 2-5/8" (68 mm)
ENERGY STAR® QUALIFIED
10.5
0.95
Sizing Chart (Number of Showers) COLDCold 5/8" (17 mm)
Climate**
Warm Climate***
3
4
3/4” NPT
3/4” NPT
Clearance (Inches) Top Bottom Side Front Back
Indoor Models GT-540-NEH
Natural
12
12
2
4
0.5
*For propane models, change “N” to “P” in the model number (example: GT-540-PI). For outdoor models change “I” to “E” in the model number (example GT-540-NE). **Cold climate represents 70˚F temperature rise. ***Warm climate represents 50˚F temperature rise
87
Commercial Gas
Tankless Heavy-Duty COMMERCIAL-GRADE COPPER HEAT EXCHANGER (NON-ASME MODELS)
24-7/8" (632.9mm) 12-1/4" (311.5mm)
15" (381mm)
4-7/8" (122.9mm)
8" (203mm)
1/2" (11.9mm)
5" (127mm)
ASME MODELS AVAILABLE
25-1/4" (642mm)
VERTICAL OR HORIZONTAL VENTING INSTALLATION
28-7/8" (734mm)
2-1/2" (62.1mm)
5” CATEGORY III STAINLESS STEEL VENTING
POWER VENT DESIGN ELECTRONIC IGNITION 1/2" (12.5mm)
®
LOW NOx EMISSIONS
4-3/8" (110.8mm) GAS -3/8" (137.3mm) HOT
COMBINED INDOOR/OUTDOOR MODELS EASY-LINK UP TO 4 NITS MULTI-LINK UP TO 10 UNITS WARRANTY
Fuel Type
Gas Consumption Input Min. BTU/H
Max. BTU/H
Inlet Gas Pressure Thermal Efficiency Min. Max. W. C. W. C.
GPM***
GT-910-NIE
Natural
15,000
380,000
80%
5
10.4
0.5-14.5
GT-910-PIE
Propane
15,000
380,000
82%
8
14
0.5-14.5
AGT-910-NIE
Natural
15,000
380,000
80%
5
10.4
0.5-14.5
AGT-910-PIE
Propane
15,000
380,000
82%
8
14
0.5-14.5
• 10-Year limited warranty on heat exchanger • 5-year limited warranty on all parts
7-3/8" (186mm)GAS
5-7/8" (150mm) HOT
7-5/8" (194.3mm) COLD
Model Number**
4" (100mm) 120V
1-5/8" (40mm) COLD
6-3/4" (171.3mm) 120V
Dimensions in Inches Model Number**
Volt
AMP
Height
Width
Depth
GT-910-NIE
25-1/4
24-7/8
12-1/4
120
1.48
GT-910-PIE
25-1/4
24-7/8
12-1/4
120
1.48
AGT-910-NIE
25-1/4
24-7/8
12-1/4
120
1.48
AGT-910-PIE
25-1/4
24-7/8
12-1/4
120
1.48
Model Number**
Flue
Intake
GT-910-NIE
5” O.D.
5” O.D.
1” NPT
113
GT-910-PIE
5” O.D.
5” O.D.
1” NPT
113
AGT-910-NIE
5” O.D.
5” O.D.
1” NPT
113
AGT-910-PIE
5” O.D.
5” O.D.
1” NPT
113
Hot/Cold Gas Approx. Shipping Conn. Weight (lbs)
*ASME Models **Outdoor installations require vent cap. ***Current numbers based on factory testing; 0.5 GPM required for activation; 0.4 GPM required for continuous fire after initial ignition.
88
89
Light-Duty
Commercial Electric HOT WATER OUTLET LDCE31
GLASSLINED TANK • Thirteen sizes, 6 thru 119 gallon capacity. Tank interior is coated with glass specially designed by American for water heater use.
ELEMENTS
TOP VIEW LDCE31 6/10/15/20
HOT WATER OUTLET LDCE31
3/4” NPT RELIEF VALVE OPENING
• Zinc plated copper sheaths for longer life. • Medium watt density means lower surface temperature to minimize scale build-up and more surface to heat water. Element sizes from 1.5 to 6 kW. Maximum input 12 kW.
STANDARD VOLTAGES • 120,277 single phase and 208, 240 and 480V unbalanced three-phase delta; easily converted to single-phase at terminal block (except 208V with 6000 watt elements). Single element heater, single-phase only.
“B”
Element Wattage (Upper/Lower)
“D” “B”
ELECTRICAL CONNECTION 2 1/2” (63.5 mm) INLET 3/4” (FEMALE) JUNCTION NPT BOX
“C”
6 8
/2500
GPH
10
3000/3000
GPH
12
4000/4000
GPH
16
4500/4500
GPH
18
5000/5000
GPH
20
6000/6000
GPH
24
3000/3000
GPH
24
4000/4000
GPH
32
4500/4500
GPH
36
5000/5000
GPH
41
6000/6000
GPH
49
Simultaneous Operation
90
“C”
TOP VIEW 2 1/2” LDC32-30 - 120 (63.5 mm) “B”
“A”
“A”
DRAIN VALVE 3 3/4” (95.25 mm)
FRONT VIEW LDC32- 30/40/50
Compact Models LDC31-06L LDCE31-10L LDCE31-15L LDCE31-20L Lowboy Models LDCE32-30L LDCE32-40L LDCE32-50L Tall Models LDCE32-30H LDCE32-40R LDCE32-50R LDCE32-65H LDCE32-80H LDCE32-119R
GPH
JUNCTION BOX
3 3/4” (95.25 mm)
FRONT VIEW LDC32- 30-120
Dimensions in Inches
Approx. Shipping Weight (lbs)
Gallon Capacity
A
B
C
D
6 10 15 20
15-1/2 18-1/4 26 22-1/4
14-1/4 18 18 21-3/4
11 12-1/2 20-1/2 15-3/8
N/A N/A N/A N/A
35 52 58 73
30 40 50
30-7/8 32-1/4 32-1/4
21-3/4 24 26-1/2
24-1/8 25-9/16 25-1/8
8 8 8
100 125 166
30 40 50 65 80 119
34-1/2 45-1/8 54-7/8 60-3/4 59-3/8 62-7/16
20-1/2 20-1/2 20-1/2 21-3/4 24 29-3/8
N/A N/A N/A N/A N/A N/A
8 8 8 8 8 8
93 113 131 176 211 326
Non-Simultaneous Operation GPH
3/4” NPT RELIEF VALVE OPENING
3 3/4” NPT RELIEF VALVE OPENING BRASS DRAIN VALVE
INLET 3/4” (FEMALE) NPT
“D”
“A”
TOP VIEW LDC32-30/40/50
Model Number
/2000
INLET OUTLET 3/4” (FEMALE) 3/4” (FEMALE) NPT NPT
FRONT VIEW LDCE31 6/10/15/20 “B” *(NO SIDE OUTLET AVAILABLE FOR LDCE31-6 MODELS)
100
/1500
FRONT VIEW LDCE31 6/10/15/20 *(NO SIDE OUTLET AVAILABLE FOR LDCE31-6 MODELS)
ALTERNATE OUTLET 3/4” (FEMALE) NPT
U. S. Gallons/Hr at Temperature Rise Indicated F°
INLET 3/4” (FEMALE) NPT
TOP VIEW LDCE31 6/10/15/20
OUTLET 3/4” (FEMALE) NPT OUTLET 3/4” (FEMALE) 3/4” NPTNPT RELIEF VALVE OPENING
“A”
“C”
ELECTRICAL CONNECTION
TERMINAL BLOCK • Factory-installed. Just bring the service to heater and connect to block. Terminal block not supplied on 120V & 277 volt models. (No junction box on LDC31-06L thru LDCE31-20L)
ALTERNATE OUTLET 3/4” (FEMALE) NPT
OUTLET 3/4” (FEMALE) NPT
91
Heavy-Duty Surface Mount Thermostats
Commercial Electric
GOLD ELEMENTS • Models ship with Goldenrod 24K gold plated elements
WATER OUTLET
• Patented Goldenrod elements provide long life and superior scaling resistance.
C
• Low watt density means lower surface temperature to minimize scale buildup and more surface to heat water. Goldenrod elements carry a one-year warranty against failure due to lime scale build up.
CONDUIT OPENING
FUSING • Protects all elements, thermostats and internal wiring circuits against excess current flow. Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps.
3/4” NPT OPENING
MEETS THE STANDBY LOSS REQUIREMENTS OF THE U.S. DEPARTMENT OF ENERGY AND CURRENT EDITION OF AHRAE/ IESNA 90.1. 3-YEAR LIMITED TANK AND 1-YEAR LIMITED PARTS WARRANTY
A
• For complete warranty information, consult written warranty or go to americanwaterheater.com.
INLET OPENING
DRAIN VALVE
5.25
B
Model Number
Gallon Capacity
Dimensions in Inches A
B
C
Approx. Shipping Weight (lbs)
STCE31-52
50
55-3/4
21-3/4
27
265
STCE31-80
80
60-1/4
25-1/2
31
280
STCE31-120
119
62-1/4
29-1/2
35
390
208 volt models may use three additional elements. 54 kW not available in 208 single phase. For ASME tank construction add “A” to the front of the model number.
92
93
Commercial Electric
Heavy-Duty Immersion Thermostats ADVANCED ELECTRONIC CONTROL
WATER OUTLET
• Plain English text and animated icons display diagnostics.
C
ECONOMY MODE OPERATION • Lowers the operating set point and reduces operating costs
CONDUIT OPENING
THERMOSTATIC LINEAR SEQUENCING CONTROL HELPS REDUCE CURRENT SURGES AND PROVIDES ACCURATE CONTROL OF WATER TEMPERATURE
3/4” NPT OPENING
GOLDENROD ELEMENTS • All ITCE31 models ship standard with patented Goldenrod 24K gold plated elements. Goldenrod elements provide long life with superior scaling resistance.
DISPLAY FOR ELECTRONIC CONTROL MODELS ONLY
3-YEAR LIMITED TANK AND 1-YEAR LIMITED PARTS WARRANTY
A
• For complete warranty information, consult written warranty or go to americanwaterheater.com. INLET OPENING
DRAIN VALVE
5.25
B
Dimensions in Inches
Model Number
Gallon Capacity
A
B
C
Approx. Shipping Weight (lbs)
ITCE31-50*
50
55-3/4
21-3/4
27
265
ITCE31-80
80
60-1/4
25-1/2
31
280
ITCE31-120
119
62-1/4
29-1/2
35
390
*ITCE31-50 is maximum 36kW See specification sheet or contact your local rep for optional kW’s available
94
95
Commercial Storage Tanks
Standard Jacketed GLASSLINED PER ASME, HLW PROCEDURES
ASTJ-80T TJ-80A
TJ-80A
TJ-80A
HIGH-DENSITY, FIBERGLASS INSULATED JACKETS OR BARE 3/4" NPT (ANODE ) STEEL TANKS
3/4" NPT (ANODE )
1" NPT
2" NPT
2" NPT 26 1/2"
2" ASME INSPECTION OPENING (PLUGGED)
26 1/2"
2" NPT FRONT & REAR
ANODIC PROTECTION
TJV-120M • For complete warranty information, consult written warranty or go to americanwaterheater.com
2" NPT FRONT & REAR
ASME PLATE UNDER COVE R
54 7/8"
54 7/8"
42 3/4" 3/4" NPT REAR 32 1/4"
42 3/4"
2" NPT FRONT & REAR 3/4" NPT REAR
3/4" NPT FRONT
3/4" NPT FRONT
2" NPT FRONT & REAR
2" NPT FRONT & REAR
16" 2" ASME INSPECTION 2" ASME INSPECTION 3/4" NPT 7" OPENING (PLUGGED) OPENING (PLUGGED) REAR
3/4" NPT REAR
3 3/4"
2" NPT
2" NPT
3/4" NPT (ANODE )
3/4" NPT (ANODE )
3/4" NPT (ANODE )
1" NPT FRONT
2" NPT FRONT
1" NPT FRONT
1" NPT FRONT
2" NPT FRONT
2" NPT FRONT
2" NPT FRONT
42 1/4"
15"
11" 4 1/8"
15"
4 1/8"
Model Number STJ5-80T STJV5-120T
Gallon Capacity 80 119
80 119 175
Approx. Shipping Weight (lbs) Overall Length Jacket Diameter 26-1/2 28 32
369 411 560
2" ASME INSPECTION OPENING (PLUGGED)
9 3/4"
61 3/4"
3/4" NPT LOCA TED UNDER 50 1/2" COVE R 44 1/2"
63" 51 1/4" 7/8" 21
17 3/4" 47" 109 3/4" 3/4"
2" ASME INSPECTION OPENING (PLUGGED) 16"
17 3/4" 10 3/4"
7"
2" NPT
2" ASME INSPECTION 2" ASME INSPECTION OPENING (PLUGGED) 32 " OPENING (PLUGGED)
1" NPT
3 3/4"
1" NPT
ASTJV5-200M TJV-200M 2" NPT
3/4" NPT
3/4" NPT ) 77(ANODE "
77 "
2" NPT FRONT 3/4" NPT 50 1/2" 2" NPT FRONT & REAR 44 1/2"
61 ASME 3/4" PLATE
STJV5-120T TJV-120M
236 320
Dimensions in Inches
57-7/8 61-3/4 77
2" NPT FRONT & REAR 2" ASME INSPECTION 2" NPT OPENING (PLUGGED)
1" NPT
64"
64"
3/4" NPT
3/4" NPT
3/4" NPT (ANODES)
2" NPT
2" NPT
ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER
ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER
TJ 1" NPT
2" NPT
2" ASME INSPECTION 17 1/4" 17 1/4" 17 1/4" 12 12 1/4" 12 1/4" 1/4" OPENING (PLUGGED)
17 1/4" 29 3/8"
ASME RATING PLATE AND 12 1/4" HAND HOLE LOCATED UNDER COVER
ASME
ASTJ-80T ASTJV5-120T ASTJV5-200M
21 1/4"
2" NPT
64"
Gallon Capacity
3/4" NPT FRONT
REAR
2" ASME INSPECTION OPENING (PLUGGED)
ASME PLATE LOCA TED UNDER COVE R
1" NPT
3/4" NPT 21 1/4" 2" NPT FRONT (ANODES) & REAR 9 3/4"
(ANODES)
NPT 323/4" "
32 "
28" 1" NPT
2" NPT FRONT
3/4" NPT REAR 3/4" NPT
3/4" NPT 50 1/2" 44 1/2"
3/4" NPT 19 1/2" (ANODES) 3/4" NPT 11" 9 3/4" FRONT
77 "
Model Number
28"
TJV-200M
2" NPT FRONT & REAR
FRONT & REAR 32 1/4" 3 1/2"
2" ASME INSPECTION OPENING (PLUGGED)
25-1/4 29-3/8
2
1-1/4" NPT (ANODE )
1" NPT
1-1/4" NPT (ANODE )
ASME PLATE UNDER COVE R
61 3/4"
4 1/8" 42 3/4"
3/4" NPT FRONT
Approx. Shipping Weight (lbs) Overall Length Jacket Diameter
TJV-120A
2" ASME INSPECTION 28" OPENING (PLUGGED)
26 1/2"
2" ASME INSPECTION OPENING (PLUGGED)
Dimensions in Inches 63 62
54 7/8"
3/4" NPT FRONT
2" NPT FRONT & REAR
3 1/2"
1" NPT
2" NPT
2" NPT FRONT
11"
TJV-200M 2" NPT
3 1/2"
11"
3/4" NPT REAR
2" NPT
2" NPT FRONT & REAR 54 1/4"
15"
3 3/4"
3/4" NPT REAR
TJV-120A
1" NPT
TJV-200M
42 1/4"
3 3/4"
2" NPT
1" NPT
62" 54 1/4"
7"
ASTJV5-120T TJV-120A
62" 42 1/4"
2" NPT FRONT & REAR
16" 7"
29 3/8"
29 3/8"
54 1/4"
3/4" NPT FRONT
47"
3/4" NPT REAR
TJ-80A
3/4" NPT (ANODE )
62"
51 7/8"
47"
TJV-120M
2" NPT
2" NPT FRONT
51 7/8"
16"
2" ASME INSPECTION OPENING (PLUGGED)
TJV-120M
63"
3/4" NPT 51 7/8" 47" FRONT
29 3/8"
NON-ASME
3/4" NPT REAR
3/4" NPT REAR
63"
3/4" NPT REAR
19 1/2" 11" 9 3/4" 2" NPT FRONT & REAR
25 1/4"
2" NPT FRONT & REAR
3/4" NPT REAR 63"
32 1/4"
19 1/2" 11" 9 3/4"
3/4" NPT FRONT
25 1/4"
2" NPT FRONT & REAR
ASME PLATE UNDER COVE R
MEETS R12.5 MINIMUM THERMAL 54 7/8" INSULATION REQUIREMENTS OF 42 3/4" THE U.S. DEPARTMENT32OF ENERGY 1/4" AND CURRENT EDITION OF 19 1/2" 11" 9 3/4" ASHRAE/IESNA 90.1 5-YEAR HEAT EXCHANGER AND 1-YEAR PARTS LIMITED WARRANTY
2" NPT FRONT & REAR
ASME PLATE UNDER COVE R
3/4" NPT (ANODE )
3/4" NPT (ANODE )
2" ASME INSPECTION OPENING (PLUGGED) 25 1/4"
2" ASME INSPECTION 26 1/2" OPENING (PLUGGED)
TJ-80S 2" NPT
2" NPT
1" NPT
2" NPT
ASME CONSTRUCTION ON SELECTED MODELS
STJ5-80T TJ-80S
TJ-80S
3/4" NPT1" NPT (ANODE )
17 1/4" 12 1/4"
17 1/4" 12 1/4"
1" NPT FRONT
2" NPT 32 "
2" NPT FRONT
1" NPT
62" 54 1/4"
2" NPT FRONT
42 1/4"
77 "
3/4" NPT 61 3/4" 3/4" NPT 2" NPT 50 1/2" 44 1/2" ASME RATING PLATE AND HAND HOLE LOCATED UNDER COVER 21 1/4"
TJV-200M
64" 15"
11"
3/4" NPT (ANODES)
4 1/8"
3 1/2"
9 3/4"
2" NPT FRONT & REAR
17 1/4" 12 1/4"
17 1/4" 12 1/4"
3/4" NPT FRONT
2" ASME INSPECTION OPENING (PLUGGED)
2" NPT 32 " 1" NPT
96
3/4" NPT 2" NPT
77 " 64"
ASME RATING PLATE AND HAND HOLE LOCATED
97
American Water Heaters | 500 Tennessee Waltz Parkway | Ashland City, TN 37015 800.937.1037 | americanwaterheater.com NMBCA00108 | © August 2015 American Water Heaters | Printed in U.S.A.