ANT04 Low Profile Antenna
Product Manual ASL Document Ref.: U-0464-0248.doc Issue: 1.07 comlete, approved - Date: 13/08/10 part Number: M0464_138
ANT04 - Product Manual
This product must be disposed of in accordance with the WEEE directive.
Application Solutions Limited Head Office: The Riverside Centre Railway Lane Lewes - East Sussex BN7 2AQ - UK Tel: +44(0)1273 476608
Fax +44(0)1273 478888
Voice Alarm Direct: Tel: +44(0)1273 405411
Fax: +44(0)1273 405415
www.asl-electronics.co.uk
All rights reserved. Information contained in this document is believed to be accurate, however no representation or warranty is given and Application Solutions Limited assumes no liability with respect to the accuracy of such information. Issue: 1.06 complete, approved Page 2 of 16
ANT04 - Product Manual
Contents Safety and Precautions..........................................................................................................4 Environmental.......................................................................................................................................... 4 Unpacking and Handling ......................................................................................................................... 4 Packing for Return for Repair .................................................................................................................. 4
Abbreviations .........................................................................................................................4 Description..............................................................................................................................5 Antenna Parameters................................................................................................................................ 5
Installation ..............................................................................................................................9 Connections............................................................................................................................................. 9 Mounting Positions .................................................................................................................................. 9 Installation Requirements ...................................................................................................................... 10 General Requirements .......................................................................................................................... 10 Cabling Requirements ........................................................................................................................... 10 Recommended Installation Procedure .................................................................................................. 10
Fault Finding and Maintenance...........................................................................................11 Fault Finding.......................................................................................................................................... 11 Maintenance .......................................................................................................................................... 11
Product Specification ..........................................................................................................12 Mechanical Dimensions.......................................................................................................13 Service and Warranty...........................................................................................................14 Exclusions ............................................................................................................................................. 14
Index ......................................................................................................................................15
Issue: 1.06 complete, approved Page 3 of 16
ANT04 - Product Manual
Packing for Return for Repair
Safety and Precautions
!
Environmental The temperature and humidity ranges shown in the specifications for these products must not be exceeded. This equipment must not be installed in an area that is subject to a corrosive atmosphere, excessive moisture or may allow water or other liquids to come into contact with the unit or its external connections.
! !
The unit must be installed away from large metallic structures.
Unpacking and Handling !
This equipment is heavy. Please lift and handle with care to avoid strain or drop injuries.
The equipment should be unpacked and inspected immediately on receipt. If damage has occurred please advise your carrier or supplier. It is advisable to retain the original equipment packing in the event that the equipment ever needs returning for service. Ensure that the name and address of the Authorised Distributor from whom you purchased the unit is recorded on the “Service and Warranty” page of this manual for future reference.
All electronics assemblies must be properly packed in ESD protective packing for transport, to prevent physical and ESD damage. Use of non-ESD protective packing for return for repair or service will automatically invalidate the warranty.
The filler material used for packing for return for repair must be antistatic or static dissipative, as this may come into contact with exposed connectors, wiring, or PCB assemblies. The use of nonconductive filler material may cause damage to the electronic assemblies reducing their operational life, or even destroying them, and it will automatically invalidate the warranty.
Advice on packing the product for return can be provided by Application Solutions Limited.
Abbreviations ABS
Acrylonitrile Butadiene Styrene
ANT04
Low Profile Antenna
EMC
Electromagnetic Compatibility
ESD
Electrostatic Discharge
I/O
Input/Output
LSZH
Low Smoke Zero Halogen
RH
Relative Humidity
RF
Radio Frequency
UL
Underwriters Laboratories Inc.
VSWR
Voltage Standing Wave Ratio
Issue: 1.06 complete, approved Page 4 of 16
ANT04 - Product Manual
Description The ANT04 is a low profile omnindirectional radio microphone antenna. It is suitable for 840 – 880MHz applications. All components are enclosed in a light weight and weather resistant flame retardant LSZH ABS moulding. The ANT04 is supplied as a fully assembled and sealed unit ready for fixing to the mounting surface, typically on a wall or ceiling.
Antenna Parameters Figure 1
ANT04 Horizontal Azimuth Pattern
Issue: 1.06 complete, approved Page 5 of 16
ANT04 - Product Manual
Figure 2
ANT04 Longitudinal Azimuth Pattern
Issue: 1.06 complete, approved Page 6 of 16
ANT04 - Product Manual
Figure 3
ANT04 Smith Chart
Issue: 1.06 complete, approved Page 7 of 16
ANT04 - Product Manual
Figure 4
ANT04 Voltage Standing Wave Ratio (VSWR) Plot
Issue: 1.06 complete, approved Page 8 of 16
ANT04 - Product Manual
Installation Connections Figure 5
ANT04 Connection Points
2
2
1
2
2
1
Antenna RF connection (50Ω female N-type connector)
2
Four fixing holes (4.60mm diameter)
Mounting Positions Figure 6
ANT04 Mounting Positions
Transversely mounted on ceiling
Vertically mounted on wall
Issue: 1.06 complete, approved Page 9 of 16
ANT04 - Product Manual
Installation Requirements General Requirements •
This ANT04 unit
•
Fixing screws or bolts suitable for the unit’s fixing holes (4.60mm diameter)
•
Screwdrivers suitable to the fixing screws
Cabling Requirements •
Installation cabling connector: 50Ω male N-type connector
•
50Ω coaxial cabling of suitable loss for the cable length, the receiver and transmitter to be used
•
Length: ideally any factor of 0.348m, e.g. 10.46 m
Recommended Installation Procedure
!
Please read and observe the “Safety and Precautions” section of this manual.
Please refer to Figure 5 to locate the connection points. 1.
Mark the surface on which the ANT04 will be fitted. The ANT04 unit’s four fixing holes are on 179.33mm x 53.30mm centres. See “Mechanical Dimensions” for details.
!
The unit must be installed away from large metallic structures.
2.
Prepare the mounting holes appropriately.
3.
Fit the unit to the mounting position and fix it in position using the selected fixings and appropriate tools.
4.
Connect the antenna RF connection to the coaxial installation cabling.
5.
The antenna installation is complete.
Issue: 1.06 complete, approved Page 10 of 16
ANT04 - Product Manual
Fault Finding and Maintenance Fault Finding The most likely failure of the ANT04 is through corrosion of the external connection, and this should be thoroughly checked if there is any suspicion that the unit is not passing the required strength of RF signal.
Maintenance There is no relevant maintenance action to be carried out.
Issue: 1.06 complete, approved Page 11 of 16
ANT04 - Product Manual
Product Specification Electrical Frequency...................................................................................................................... 840 − 880MHz Bandwidth.................................................................................................................................. 40MHz Impedance......................................................................................................................................50Ω Gain ................................................................................................................................................ 6dB VSWR........................................................................................................................................... 1.2:1 Effective range under normal operating conditions....................................................................... 60m Internal feedline........................................................................................................................... RG58 Mechanical Connector ...................................................................................................................... N type, female Materials Enclosure Enclosure.................................................................................................. Flame retardant LSZH ABS UL flammability rating.................................................................................................................. 94VO Impact rating.................................................................................................................................. IK54 Heat deflection temperature 455kPa .................................................................................................................................. +85°C 1820kPa ................................................................................................................................ +74°C Specific gravity .............................................................................................................................. 1.22 Rockwell hardness .......................................................................................................................100R Others Gasket ..............................................................................................................................LSZH Silicon Connector .................................................................................................................................... Brass Elements...........................................................................................................................................Tin Others Colour ...........................................................................................................................................Black Dimensions and Weight Dimensions (H x W x L).....................27.98mm x 70.61mm x 193.26mm (incl. flange and connector) Weight .......................................................................................................................................... 150g Environmental Temperature (storage and operating) ......................................................................... −20°C to +85°C Humidity range .........................................................................................0% to 93% Non-condensing
Issue: 1.06 complete, approved Page 12 of 16
ANT04 - Product Manual
Mechanical Dimensions Figure 7
Mechanical Dimensions 70.61mm
53.30mm
193.26mm
190.91mm
179.33mm
165.61mm
4.60mm diameter
27.98mm
Issue: 1.06 complete, approved Page 13 of 16
ANT04 - Product Manual
Service and Warranty This product carries a full warranty. For full details of warranty and service agreements, please contact the Authorised Distributor who supplied the product to you.
Exclusions The warranty does NOT cover: 1.
Customer misuse, including incorrect installation.
2.
Damage other than manufacturing defects.
3.
Transit / Courier damage.
4.
Incorrect voltage or power supply used.
5.
Incorrect input signal.
6.
Abnormal environmental operating conditions.
7.
Damage incurred by accident, fire, lightning or other hazard.
8.
Modification to the unit or inexpert / attempted repair.
9.
No fault found – where no fault can be found after extensive testing, indicating user error or failure in ancillary equipment.
10. Electronic assemblies which are improperly packed when returned for repair or service. All electronics assemblies must be properly packed in ESD protective packing for transport to prevent physical and ESD damage. Use of non-ESD protective packing for return for repair or service will automatically invalidate the warranty. Should any of the above apply, Application Solutions Limited reserves the right to raise any relevant charges to the customer. Application Solutions Limited shall not be liable for any indirect, special or consequential loss or damage (including without limitation any loss of profits) arising from the use of this product or for any breach of this warranty.
Name and Address of Authorised Distributor:
In the interest of continual product development, Application Solutions Limited reserves the right to make changes to product specification without notice or liability.
Issue: 1.06 complete, approved Page 14 of 16
ANT04 - Product Manual
Index A
E
antenna horizontal azimuth........................................5 longitudinal azimuth .....................................6 low profile.....................................................5 parameters...................................................5 Smith Chart ..................................................7 VSWR ..........................................................8
enclosure .................................................. 5, 12
C
W
connections .....................................................9
warranty ................................................ 2, 4, 14
M mounting ..................................................... 5, 9 P packing...................................................... 4, 14
D dimensions ....................................................13
Issue: 1.06 complete, approved Page 15 of 16