Apd59p-6 - Aksa Power Generation

   EMBED


Share

Transcript

59 kVA / 47 kW POWERED by PERKINS APD59P--6 APD59P 60 Hz. 1800 rpm. DIESEL GENERATING SET 480/277V, 480/277V 440/254V 440/254V, 380/220V 380/220V, 220/127V 220/127V-- 60 H Hz MODEL Power Pf. 0.8 Standby Prime APD59P-6 kVA kW kVA kW 59 47 53 42 Standby  : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 . Prime  : Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046. 9 High quality, reliable and complete power unit 9 Compact design 9 Easy start and maintenance possibility 9 Every generating set is subject to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing 9 Full engineered with a wide range of options and accessories: Canopy, sound proof canopy and on road trailer Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice. ENGINE PERKINS Model Engine Power Output at rated rpm Aspiration and Cooling Total Displacement No. of Cylinders and Build Engine Speed Bore and Stroke Compression Ratio Governor Fuel Consumption at full load Fuel Tank Capacity Oil Capacity Coolant Capacity Radiator Cooling Air Air Intake – Engine Exhaust Gas Flow 9 9 9 9 9 9 kWm HP Litre rpm mmxmm L/hr Litre Litre Litre m³/min m³/min m³/min Heavy duty Perkins diesel engine Four stroke, water cooled, turbocharged Direct injection fuel system Mechanical Governor system 12/24 V D.C. starter and charge alternator Replaceable fuel filter, oil filter and dry element air filter ALTERNATOR Design Stator Rotor Insulation System Standard Temperature Rise Exciter Type Phase Rotation Alternator Cooling AC Waveform Total Harmonic Distortion Telephone Influence Factor (TIF) Telephone Harmonic Factor (THF) 9 9 9 9 1103A-33TG1 53.9 72.3 Turbo charged 3.3 3-inline 1800 105x127 17.25:1 Mechanical 10.7 82 8.3 10.2 70 3.7 8.8 9Cooling radiator and fan 9 Starter battery (with lead acid) including Rack and Cables 9 Flexible fuel connection hoses and manual oil sump drain valve 9 Industrial capacity exhaust silencer and steel bellows 9 Jacket water heater(at automatic models) 9 Operation manuals and circuit diagram documents Brushless single bearing, revolving field 2/3 p pitch Single bearing, flexible disc Class H 125 - 163°C Continuous Self Excited A (U), B (V), C (W) Direct drive centrifugal blower fan No load < 1 1.5%. 5% Non distorting balanced linear load < 5% <50 per NEMA MG1-22.43 <2% Brushless, single bearing system, flexible disc, 4 poles 9 Impregnation with tropicalised epoxy varnish Insulation class H 9 Solid state Automatic Voltage Regulator Standard degree of protection IP21 (*IP22/IP23 is availab.) 9 Stator winding with 2/3 pitch for improved harmonics Self-exciting and self-regulating CONTROL SYSTEM Control supervision and protection panel is mounted on the genset base frame. The control panel is equipped as follows: 1. Auto Mains Failure Control Panel Panel equipments: 9 Control with AMF module 9 Static battery charger 9 Emergency stop push button DSE 6020 a) Generating set control module DSE 6020 features: 9 The module is used to monitor main supply and starts and stops of a standby generating set 9 Micro-processor based design 9 Automatic control of main and generator contactors 9 Monitors engine performance and AC power output LED alarm indication 9 Front p panel configuration g of timers and alarm trip pp points 9 CAN and magnetic pick-up versions(specify on ordering) 9 4 digital inputs/3 analogue inputs 9 6 outputs(4 configurable on Magnetic Pick-up, 6 configurable on CANbus version) 9 Easy push button control STOP/RESET - MANUAL - AUTO - TEST – START b) Metering via LED display: 9 Generator Volts (L-L (L L / L-N) L N) 9 Engine oil pressure (PSI-Bar) 9 Generator Ampere (L1,L2,L3) 9 Engine temperature (°C&°F) 9 Generator Frequency (Hz) 9 Plant battery volts 9 Engine hours run 9 Mains Volts (Ph-Ph/Ph-N) Generator kVA Generator kW Generator Cos (σ) OPTIONAL EQUIPMENTS Dlesel Englne 9 Oil heater Altemator 9 3/4 Pole Output Circuit Breaker 9 Anti-condensation Heater Panel 9 Charge ammeter 9 Transfer Switch 3Pole 9 Transfer Switch 4 Pole 9 Earth Fault ,single set c) Alarms: 9 Over and Under Speed 9 Low and High Battery Volt. 9 Start and Stop Failure 9 Charge fail 9 Over Current 9 Under / Over Generator Voltage g 9 Low Oil Pressure 9 Emergency stop 9 High engine temperature d) LED Indications: 9 Mains available 9 Generator available 9 Mains on load 9 Generator on load 2. Power Outlet Terminal Board Mounted on the Genset Base frame Panel 9 Charge ammeter 9 Transfer Switch 3Pole 9 Transfer Switch 4 Pole 9 Earth Fault ,single set Accessories 9 Bulk fuel tank 9 Automatic filling system 9 Fuel-water separator filter 9 Low fuel level alarm 9 Residential silencer 9 Enclosure or sound proof canopy 9 Trailer 9 Manual oil drain pump 9 Tool kit for maintenance CHASSIS 9 The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame 9 Antivibration pads are fixed between the engine/ alternator feet and the base frame 9 Base frame design incorporates an integral fuel tank (Up to 750 kVA) 9 The generating set can be lifted or carefully pushed/ pulled by the base frame 9 Dial type fuel gauge and drain plug on the fuel tank 9 Forklift pockets within base frame (up to 500kVA) DIMENSIONS OPEN TYPE DIMENSIONS (LxWxH) DRY WEIGHT mm kg 1730x900x1185 800 SOUND ATTENUATED TYPE DIMENSIONS (LxWxH) DRY WEIGHT mm kg 2270x969x1275 1000 CANOPY 9 All canopy parts are designed with modular principles 9 Without welding assembly 9 Doors on each side 9 All metal canopy parts are painted by electrostatic polyester powder paint 9 9 9 9 9 Exhaust silencer is protected against environment influences Thermally insulated engine exhaust system Emergency stop push button is installed outside of the canopy Easy lifting and moving Easy maintenance and operation Aksa Power Generation Evren Mah.Gulbahar Caddesi 1.Sokak Gunesli-Istanbul-TURKEY Tel:+90 212 478 66 66 Fax:+90 212 657 55 16 E-mail: [email protected] www.aksapowergen.com Aksa Power Generation is a member of www.aksa.com.tr