Pakenham Branch Library 128 MacFarlane Street Project No. 16563.001 Section Appendix B PANEL SCHEDULES Page 1 of 1 APPENDIX B PANEL SCHEDULES SMITH + ANDERSEN Issued for Tender PANEL: RP B1 LOCATION: ELECTRICAL ROOM PROJECT #: 16563.001 FED FROM: SPLITTER TYPE/ DESCRIPTION INFO D.C HWT REC WATER SOFTENER D.F CONN. DEMAND BKR CCT Φ CCT BKR DEMAND NO. [A] 2 20 CONN. D.F DESCRIPTION TYPE/ [%] LOAD [W] LOAD [W] [A] NO. LOAD [W] LOAD [W] [%] 75 2250 1688 30 1 A 75 2250 1688 2P 3 B 4 15 375 500 75 BOOSTER PUMP D.C 75 200 150 15 5 A 6 15 375 500 75 SUMP PUMP D.C REC 1125 1500 INFO 75 FUR 1 D.C REC O.C. GFI RECEPT 5 20R 25 250 63 15 7 B 8 20 500 500 100 TELEPHONE BACKBOARD 5 20R REC O.C. GFI RECEPT 5 20R 25 250 63 15 9 A 10 15 180 720 25 UTILITY REC REC REC O.C. GFI RECEPT 5 20R 25 250 63 15 11 B 12 15 375 500 75 ELECTRONIC CONTROLS/ EF D.C REC REFIGERATOR 100 750 750 15 13 A 14 15 63 250 25 GFI RECEPT WASHROOM REC REC UTILITY REC 25 720 180 15 15 B 16 15 500 500 100 BASEBOARD HEATER D.C REC GFI RECEPT (ELEV) 25 250 63 15 17 A 18 15 180 720 25 SURFACE MOUNTED RACEWAY REC D.C ELEVATOR 50 1500 750 20 19 B 20 15 180 720 25 SURFACE MOUNTED RACEWAY REC D.C FUR 2 75 1500 1125 20 21 A 22 15 180 720 25 WORKSTATIONS REC REC FLOOR MONUMENTS 25 500 125 15 23 B 24 15 D.C FORCE FLOR HEATER 100 1000 1000 15 25 A 26 15 100 SPARE REC WP GFI EXTERIOR REC 25 250 63 15 27 B 28 15 100 SPARE SPARE 100 15 29 A 30 15 100 SPARE SPARE 100 15 31 B 32 15 100 SPARE LTS EBU AND LIGHTING 100 800 800 20 33 A 34 SPACE LTS EBU AND LIGHTING 100 800 800 20 35 B 36 SPACE SPACE 37 A 38 SPACE SPACE 39 B 40 SPACE 41 A 42 PANEL OPTIONS: 2 100 SPARE SPACE 15 500 500 100 SECURITY SYSTEM BLO 120 LOAD A [KW]: 7.74 PHASE VOLTAGE [V]: :CSA ENCLOSURE RATING X SURFACE LOAD B [KW]: 5.66 LINE VOLTAGE [V]: 240 FEED THROUGH X MAIN BREAKER TOTAL [KW]: 13.4 PHASE: 1Ф SUB FEED X BOLT ON BREAKER WIRE: 3 CURRENT A [A]: 65 MAINS [A]: 125 CURRENT B [A]: 47 MAIN BREAKER [A]: 100 I.C. [kA]: 10 ISOLATED GROUND BUS SPD LEGEND: NOTES: BAS Building Automation System R.C Relay Controlled GFCI Ground Fault Circuit Interrupter M Motor AFCI Arc Fault Circuit Interrupter D.F Demand Factor SPD Surge Protection Device REC Receptacle BLO Breaker Lock On Device LTS Lighting 1. Panel Enclosure to come c/w drip hood. HID High Intensity Discharge Lighting Breaker D.C Direct Connection PANEL: RP B2 LOCATION: ELECTRICAL ROOM PROJECT #: 16563.001 FED FROM: SPLITTER TYPE/ DESCRIPTION INFO D.F CONN. DEMAND BKR CCT Φ [%] LOAD [W] LOAD [W] [A] NO. 1 A CCT BKR DEMAND CONN. D.F DESCRIPTION NO. [A] 2 40 2625 3500 75 CC 1 75 TYPE/ LOAD [W] LOAD [W] [%] INFO D.C. CONDENSING UNIT 75 3500 2625 40 D.C. 75 3500 2625 2P 3 B 4 2P 2625 3500 REC UTILITY REC 25 720 180 15 5 A 6 15 75 300 25 DURESS SYSTEM/ CONTROLS D.C. REC WORKSTATIONS 25 600 150 15 7 B 8 15 250 500 50 DOOR OPERATOR D.C. REC WORKSTATIONS 25 600 150 15 9 A 10 15 63 250 25 GFI REC WASHROOM REC REC FLOOR MOUNTED REC 25 500 125 15 11 B 12 15 500 500 100 BASEBOARD HEATER D.C. D.C. FIREPLACE 50 1500 750 20 13 A 14 15 1000 1000 100 FORCE FLOW HEATER D.C. D.C. FORCE FLOW HEATER 100 1000 1000 15 15 B 16 15 63 250 25 WORKSTATIONS REC REC HIGH MOUNTED REC 100 250 250 15 17 A 18 15 125 500 25 FLOOR MOUNTED REC REC D.C. DOOR OPERATOR 50 500 250 15 19 B 20 15 150 600 25 OFFICE REC D.C. AC 1 75 600 450 15 21 A 22 15 150 600 25 WORKSTATIONS REC SPARE 100 15 23 B 24 15 150 600 25 WORKSTATIONS REC SPARE 100 15 25 A 26 15 SPARE 100 15 27 B 28 15 SPACE 29 A 30 20 1000 1000 100 EBU AND LIGHTING LTS SPACE 31 B 32 20 1000 1000 100 EBU AND LIGHTING LTS D.C. ERV 1 DH 1 33 A 34 500 375 15 35 B 36 SPACE 75 500 375 2P 37 A 38 SPACE 75 4500 3375 50 39 B 40 75 4500 3375 2P 41 A 42 PANEL OPTIONS: 2 100 SPARE 75 SPACE D.C. 100 SPARE SPACE SPACE 15 1200 1200 100 FIRE ALARM CONTROL PANEL BLO 120 LOAD A [KW]: 9.82 PHASE VOLTAGE [V]: :CSA ENCLOSURE RATING X SURFACE LOAD B [KW]: 12.6 LINE VOLTAGE [V]: 240 FEED THROUGH X MAIN BREAKER TOTAL [KW]: 22.5 PHASE: 1Ф SUB FEED X BOLT ON BREAKER WIRE: 3 CURRENT A [A]: 82 MAINS [A]: 225 CURRENT B [A]: 105 MAIN BREAKER [A]: 200 I.C. [kA]: 10 ISOLATED GROUND BUS SPD LEGEND: NOTES: BAS Building Automation System R.C Relay Controlled GFCI Ground Fault Circuit Interrupter M Motor AFCI Arc Fault Circuit Interrupter D.F Demand Factor SPD Surge Protection Device REC Receptacle BLO Breaker Lock On Device LTS Lighting 1. Panel Enclosure to come c/w drip hood. HID High Intensity Discharge Lighting Breaker D.C Direct Connection