Preview only show first 10 pages with watermark. For full document please download

Applications And Products 2004

   EMBED


Share

Transcript

Hilti (Thailand) Ltd. 46/31-32, 8 th Fl., Nation Tower Bangna - Trad Rd. Km. 4.5 Bangna, Bangkok 10260 Thailand Tel : 0 - 2751 - 4123 - 27 Fax : 0 - 2751 - 4116 E-mail : [email protected] Hilti Service Center 98/1 Moo 1, Kingkaew Rd, Rajathewa, Bangpli, Samutprakarn 10540 Tel : 0 - 2317 - 0830 - 31 Fax : 0 - 2317 - 0832 Website : http://www.hilti.co.th Applications and products 2004 choose Hilti ... SAFETY PERFORMANCE Lower your risk with quality assured supported products. Bespoke products for applications maximising your return on investment. RELIABILITY SUPPORT Systems with long lasting performance assured by 2 years and 1 year full service cover on qualifying tools. Testing on other systems. Deal direct with the manufacturer, national coverage and site based support. INNOVATION PRODUCTIVITY New building methods developed as a result of close contact with users. Faster, easier to use systems. Measuring systems Drilling and chiselling systems Diamond systems Direct fastening systems Anchoring systems Construction chemicals and firestop systems Page Measuring systems 2-3 Drilling and chiselling systems 4-14 Diamond systems 15-23 Direct fastening systems 24-28 Anchoring systems 29-53 Construction chemicals and firestop systems 54-60 Measuring systems Laser range meters PD 30 / PD 32 Pocket-sized measuring power Applications Fast and reliable measurements up to 200 m (600 ft) Calculate areas, volumes, offsets and perimeters at the touch of a button Set out distances with just one person without need to be at the target Indirect distance measurements to inaccessible places Checking squares and parallels Technical data Accuracy* : Range** : Measuring time : Reference points : Side measuring key : Optical sight : Bubble : Laser : Functions : Special functions : Units : Data memory : Power supply : Standard : Optional : Batterie life: Temperature range : Operating temperature : Storage temperature : Dimensions (LxWxH) : Weight : IP protection : ±1.5 mm (1/16”) 5 cm to 70 m (2” bis 200 ft) w/o target plate, with target plate PDA 50 up to 200 m (600ft) Single measurement < 0.5 sec User selectable: front, rear, spike Side measuring key for comfortable handling and overhead measurements : PD 32 Built-in optical sight for long distances and ambient light conditions Horizontal : PD 30 Horizontal and vertical : PD 32 635 nm, Class 2 (IEC 825-1), Class II (FDA 21 CFR) Area, Volume, +, 2 pythagorean functions for indirect distances, MIN/MAX for checking square and parallels : PD 32 m, mm, ft, inch, ft. fraction 1/8, ft. fraction 1/16, yard last 5 measurements or calculation results with graphics Pythagoras The Hilti PD 30/32 features a Pythagoras function that allows measurements to be taken from inaccessible objects in seconds. For example: heights of buildings. 2 AA-batteries; 2 NiMH rechargeable batteries, charge from mains 100-240 V or vehicle 12-24 V. >15,000 measurements (AA-batteries) -10°C to + 50°C -30°C to + 70°C 120x65x28 mm 220 g. IP 54 * The measuring accuracy is affected by ±(1.5 mm + 20 ppm)/±(1/16”+20 ppm) due to atmospheric conditions. This affect is typically noticeable at distances> 100 m (>300 ft). **The maximum measuring range and laser visibility depends on the reflectivity of the target and the ambient light. When measuring to targets with low reflectivity use the PDA 50 target plate. PD 30, PD 32 Laser range meter Ordering designation PD 30 laser range meter Item no. 282378 Equipped with soft pouch, 2 alkaline batteries, hand strap and user manual in a cardboard box. PD 32 laser range meter 282386 Equipped with soft pouch, 2 alkaline batteries, hand strap, target plate and user manual in a cardboard box. Accessories Order description PDA 80 charging set Item no. 282393 For all EU countries; from mains and vehicle charging; packed complete in cardboard box. PDA 81 charging set 282394 PDA 80 For all non-EU countries; from mains and vehicle charging; packed complete in cardboard box. PDA 50 target plate 282388 For extended ranges and exterior measurements PDA 62 belt clip PA 450 282391 For clicking the laser range meter to the belt. PDA 70 spike extension PDA 81 282392 For comfortable measurements from the floor and from inaccessible places PA 970 laser visibility glasses 311212 PA 940 Improves the laser visibility significantly. PA 450 tripod adaptor 337829 PA 920 tripod head adaptor for the PD 30/PD 32 PA 920 tripod tripod with 5/8” thread, height adjustable from 0.69 to 1.45 m PA 940 tripod head tripod head with 1/4” thread, fits PA 920, PA 930, and PA 931 tripods 2 310982 PDA 50 310990 PA 970 Measuring systems PS 200 Ferroscan Portable Steel Reinforcement Detection System Applications Verification of reinforcement: locate rebar when plans are not at hand, for acceptance inspectations, before structural repair or change of loads on a structure. Verification of concrete cover over reinforcement: Obtain concrete cover information over large areas for acceptance inspections, before renovation, or for quality control. Avoiding rebar hits: Avoid cutting through critical reinforcement or costly rebar hits. Detection range and accuracy (mm) Imagescan Depth 6 8 Bar Diameter 10 12 14 16 20 25 28 30 36 20 ±2 40 ±3 60 ±3 80 ±4 100 ±5 120 0 140 x 160 x 180 x ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 0 0 ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10 0 0 0 0 0 ±11.5 ±11.5 ±11.5 ±11.5 ±11.5 x x x 0 0 0 0 0 0 ±13 x x x x x x x x x x Bar diameter given. Value indicates accuracy of depth measurement in mm. 0 - bar can be detected at this depth but no depth calculated X - bar cannot be detected at this depth Valid for bars conforming to DIN 488 Quickscan recording (mm) Depth 6 8 Bar Diameter 10 12 14 16 20 25 28 30 36 20 ±2 40 ±3 60 ±3 80 ±4 100 ±5 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±3 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±4 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 Bar diameter given. Value indicates accuracy of depth measurement in mm. 0 - bar can be detected at this depth but no depth calculated X - bar cannot be detected at this depth Valid for bars conforming to DIN 488 Technical data Scanner Memory Capacity : Monitor Memory Capacity/Type : Battery Life : Protection Class : Operating Temperature Range : Scanner Dimensions / Weight : Monitor Dimensions / Weight : Minimum System Requirements for PC Software : Benefits Immediate high resolution image for a clear picture of the reinforcement. Determine bar depth and estimate diameter at any point on the image. Determine average concrete cover over large areas easily. Reduce wear on drill/core bits and tool motors when drilling through reinforcement. Reduce drilling times - important in repetitive drilling applications. Avoid potentially disastrous and costly hits on critical reinforcement. Cableless connection between Monitor and Scanner. No cable to snag or hinder your movements. Includes powerful PC software for office analysis and easy creation of reports. Ordering designation Item no. PS 200 Ferroscan System PS 200 S Scanner PS 200 M Monitor PUA 80 Charger 377645 377652 378029 377458 Up to 9 Image scans plus up to 30 m of recorded Quickscan 32 MB Removable Multimedia Card (150 Images or 75 Quickscans) Typ. 8 hour IP 54 as per IEC529 -10 °C to +50 °C 229x132x132 mm / 1.4 kg 264x152x57 mm / 1.4 kg Microsoft®Windows®98, 16 MB RAM, 8 MB free hard disk space, CD-ROM Drive, USB v1.1 interface. 3 Drilling and chiselling systems 4 Drilling and chiselling systems Rotary hammer drill TE 2 A special light weight hammer drill for anchor holes in concrete and masonry Technical data Power input : Single impact energy : Speed under load : Hammering speed under load : Dimensions : Weight : Drilling performance in medium-hard concrete with 8 mm dia. drill bit : 600 W 1.8 Joules 0-930 r.p.m. 0-4600 blows/min. 344x200x79 mm 2.3 kg 500 mm/min. Ordering designation Item no. TE 2 230 V 336793 Includes TE 2 rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. Rotary hammer drill TE 2-M The multifunctional tool for drilling concrete, masonry, brittle material, wood and metal Technical data Power input : Single impact energy when precision (fine) hammering : Single impact energy when full hammering : Speed under load 1st speed : 2nd speed : Precision (fine) hammering speed : Full hammering speed : Dimensions : Weight : Drilling performance in medium-hard concrete with 8 mm dia. drill bit : 600 W 0.6 Joules 1.8 Joules 0-930 r.p.m. 0-2200 r.p.m. 0-2400 blows/min. 0-4600 blows/min. 359x200x79 mm 2.6 kg 500 mm/min. Ordering designation Item no. TE 2-M 230 V 336776 Includes TE 2-M rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. Cordless rotary hammer TE 2-A Total mobility for drilling anchor holes Technical data Power input : Nominal battery voltage : Energy capacity : 400 W 24 V B 24/2.0 Ah, NiCd (48 Wh) B 24/2.4 Ah, NiCd (54 Wh) B 24/3.0 Ah, NiMH (72 Wh) Single impact energy : 1.5 Joules Speed under load : 900 r.p.m. Hammering speed under load : 0-4410 blows/min. Dimensions : 325x260x92 mm Weight of tool with battery / with belt adapter : 3.8 kg / 2.4 kg Ordering designation B 24/3.0 Battery BAP 24V Belt adaptor Item no. 340458 Includes with fixed TE-C (SDS) chuck, safety precautions and operating instructions. Packed in an impact-resistant plastic toolbox. B 24/3.0 battery (24V/3.0 Ah NiCd) in cardboard box 378426 C 7/24 standard charger in cardboard box 378445 BAP 24V belt adaptor in cardboard box 378491 Hilti TE 2-A cordless rotary hammer (without battery / charger) C 7/24 Charger 5 Drilling and chiselling systems Rotary hammer drill TE 6-S The light rotary hammer with variable hammering action Technical data Power input : Single impact energy, full hammering : Single impact energy, fine hammering : Speed under load : Hammering speed, full hammering : Hammering speed, fine hammering : Dimensions : Weight : Drilling performance in medium-hard concrete with 8/12/16 mm dia. : 600 W 1.8 Joules 0.6 Joules 0-880 r.p.m. 0-5100 blows/min. 0-2700 blows/min. 320x215x75 mm 2.8 kg 550/400/240 mm/min. Ordering designation Item no. TE 6-S 230 V 369023 TE 6-S+DRS 230V 369023 Includes TE 6-S rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. Rotary hammer drill TE 6-C The light rotary hammer with chiselling function Technical data Power input : Single impact energy, full hammering : Speed under load : Hammering speed, full hammering : Dimensions : Weight : Drilling performance in medium-hard concrete with 8/12/16 mm dia. : Chiselling function : 650 W 1.8 Joules 0-880 r.p.m. 0-5100 blows/min. 320x215x75 mm 2.8 kg 550/400/240 mm/min. yes Ordering designation Item no. TE 6-C 230 V 369034 TE 6-C+DRS 230V 370069 Includes TE 6-C rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. TE 6-DRS dust removal system For the TE 6 rotary hammers Technical data Power input : Suction performance : Weight : Max. working stroke : For use with TE-C/TE-CX hammer drill bits : Drill bit working length : Contact pressure : Dust container capacity : 6 mm dia. / 28 mm deep : 8 mm dia. / 30 mm deep : 12 mm dia. / 50 mm deep : Dust container regeneration : Ordering designation max. 60 W 500 I / min. 0.9 kg 105 mm 4-16 mm dia 50-100 mm 15-25 N 130 holes 75 holes 30 holes up to 100 cycles Item no. Dust Remove TE6-DRS 370028 Includes dust removal module with suction fan, dust container with filter, depth gauge, length stop, plug-in coupling. 6 TE 6-S+DRS 369023 TE 6-C+DRS 370069 TE 6-DRS 370028 Drilling and chiselling systems Cordless rotary hammer TE 6-A 36 Volt power for peak performance Technical data Power input : Nominal battery voltage : Energy capacity : Single impact energy : Speed under load : Hammering speed under load : Dimensions : Weight with battery / with belt adapter : 375 W 36 V 86 Wh 1.5 Joules 0-890 r.p.m. 0-5000 blows/min. 330x225x100 mm 4.7 kg / 2.8 kg Ordering designation Item no. TE 6-A Strandard 332012 Includes TE 6-A with TE-C+ (SDS) chuck, side handle, dust shield, cleaning cloth, operating instruction and safety precaution. Packed in an impactresistant Hilti case. BP 6-86 Battery 332031 TCU 7/36 Charger 332021 TE 6-A Belt adaptor 333848 BP 6-86 Battery TCU 7/36 Charger TE 6-A Belt adaptor Rotary hammer drill TE 15 High drilling performance, long life expectancy Technical data Power input : Single impact energy : Speed under load : Hammering speed under load : Dimensions : Weight : Drilling performance in medium-hard concrete using a 12 mm dia. drill bit : Ordering designation 650 W 2.2 Joules 0-700 r.p.m. 0-3800 blows/min. 350x190x900 mm 3.9 kg 370 mm/min. or 42 cm3/min Item no. TE 15 230 V 228875 Includes TE 15 rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. Rotary hammer drill TE 25 Quick, robust and convenient Technical data Power input : Single impact energy : Speed under load Hammering speed under load : Dimensions : Weight : Supply cord length : Ordering designation 830 W 3.8 Joules 1st speed: 0-310 r.p.m. 2nd speed: 0-640 r.p.m. 0-3720 blows/min. 440x220x100 mm 4.9 kg 4m Item no. TE 25 230 V 308327 Includes TE 25 rotary hammer complete with side handle, depth gauge, dust shield, impact resistant plastic tool case and operating instruction. 7 Drilling and chiselling systems TC-C drill bits TE-CX drill bits Dia. (mm) Working length (mm) Ordering designation 5 5 6 6 7 8 10 12 50 80 50 100 100 100 100 100 TC-C 5/12 TC-C 5/15 TC-C 6/12 TC-C 6/17 TC-C 7/17 TC-C 8/17 TC-C 10/17 TC-C 12/17 Item no. 252998 252999 253000 253005 253006 253007 253014 253015 TE-CX drill bits Dia. (mm) Working length (mm) Ordering designation 18 18 18 20 20 20 22 22 24 25 25 28 28 150 250 400 150 250 400 200 410 200 200 410 200 410 TE-CX 18/22 S TE-CX 18/32 S TE-CX 18/47 S* TE-CX 20/22 S TE-CX 20/32 S TE-CX 20/47 S* TE-CX 22/27 S TE-CX 22/48 S* TE-CX 24/27 S TE-CX 25/27 S TE-CX 25/48 S* TE-CX 28/27 S TE-CX 28/48 S* Item no. 345827 345828 345829 345830 345831 345832 345834 345835 345836 345838 345839 345842 345843 *Predrill at least 150 mm deep with a short drill bit of the same diameter and product on request. Dia. (mm) Working length (mm) Ordering designation 5 5 5 5 5.5 5.5 6 6 6 7 8 8 8 8 8 8 8.5 9 10 10 10 10 10 10 10 11 12 12 12 12 12 12 12 14 14 14 14 14 15 15 16 16 16 16 16 50 80 100 150 50 80 50 100 150 100 50 100 150 200 250 400 100 150 50 100 150 200 300 400 540 150 50 100 150 200 300 400 540 100 150 200 300 400 100 200 100 150 200 400 550 TE-CX 5/12 TE-CX 5/15 TE-CX 5/17 TE-CX 5/22 TE-CX 5.5/12 TE-CX 5.5/15 TE-CX 6/12 TE-CX 6/17 TE-CX 6/22 TE-CX 7/17 TE-CX 8/12 TE-CX 8/17 TE-CX 8/22 TE-CX 8/27 TE-CX 8/32 TE-CX 8/47 TE-CX 8.5/17 TE-CX 9/22 TE-CX 10/12 TE-CX 10/17 TE-CX 10/22 TE-CX 10/27 TE-CX 10/37 TE-CX 10/47 TE-CX 10/61 TE-CX 11/22 TE-CX 12/12 TE-CX 12/17 TE-CX 12/22 TE-CX 12/27 TE-CX 12/37 TE-CX 12/47 TE-CX 12/61 TE-CX 14/17 TE-CX 14/22 TE-CX 14/27 TE-CX 14/37 TE-CX 14/47 TE-CX 15/17 TE-CX 15/27 TE-CX 16/17 TE-CX 16/22 TE-CX 16/27 TE-CX 16/47 TE-CX 16/62 8 Item no. 205297 205298 205300 205301 205302 205303 205304 205305 205306 205312 205314 205315 205317 205318 205319 205321 205322 205325 205329 205330 205331 205332 205333 205334 205335 205338 205341 205342 205343 205344 205347 205348 205349 205356 205357 205358 336685 205360 205364 205366 205372 205373 333739 205375 205376 TE-C-DS Thin barrel core bits Metal carbide tips Dia. (mm) Working length (mm) Ordering designation 25 25 32 32 50 68 130 170 130 170 130 130 TE-C-DS 25/130 TE-C-DS 25/170 TE-C-DS 32/130 TE-C-DS 32/170 TE-C-DS 50/130 TE-C-DS 68/130 Item no. 339125 339126 339127 339128 339129 339130 TE-C chisels for TE 6-C Blade width (mm) Total length (mm) Ordering designation 15 15 180 250 180 250 TE-C-SM 18 pointed TE-C-SM 25 pointed TE-C-FM 18 narrow flat TE-C-FM 25 narrow flat Item no. 204730 30219 204731 30220 Drilling and chiselling systems Accessories Quick-release chuck with leaf turn lock For twist drills with cylindrical connection ends up to 13 mm diameter, for rotary drilling only Ordering designation Quick-release chuck (for TE 6-S, TE 6-C, TE 6-A, TE 15) Item no. 70639 Key-type chuck complete For twist drills with cylindrical connection ends up to 13 mm diameter, suitable for clockwise and counter-clockwise rotation and high torque Ordering designation Key-type chuck complete (for TE 6-S, TE 6-C, TE 6-A, TE 15) Item no. 70640 Accessories for TE 2 Quick-release chuck For cylindrical shank twist drills up to 13 mm diameter for drilling without hammering Ordering designation Item no. Quick-release chuck 13 60208 Chuck spindle TE-C-BFH 60459 Accessories for TE 2-M For TE-CX drill bits with TE-C connection end Ordering designation Item no. Quick-release chuck TE 2-M 338905 For insert tools with cylindrical connection up to 13 mm dia. for use without hammering action, secure in reverse rotation. Accessories for TE 25 Special chuck for twist drills with cylindrical shank up to 13 mm diameter for drilling without hammering Ordering designation Quick-release chuck Item no. 30201 Angle chuck TE-AC (for TE 5, TE 5-A, TE 6-S, TE 6-C, TE 6-A, TE 15) Ordering designation TE-AC Angle chuck weight 1.45 kg, optimum drilling diameter in concrete 5-16 mm Item no. 70591 9 Drilling and chiselling systems Combihammer TE 56 Innovative lightweight combihammer Technical data Power input : 1100 W Single impact energy : 100% : 7.0 J/ 50% : 3.5 J Speed under load : power level I : 0-480 r.p.m. power level II : 0-720 r.p.m. (ATC) Hammering speed under load : 0-2886 blows/min. Dimensions (LxWxH) : 475x240x95 mm Weight : TE 56 : 5.9 kg Drilling performance in medium-hard concrete with 20 mm dia. : 350 mm/min. Ordering designation Item no. TE 56 230 V 374049 Includes TE 56 complete with side handle, depth gauge, dust shield, Hilti grease, cleaning cloth, impact resistant plastic tool case and operating instruction. Combihammer TE 76 / TE 76-ATC Megapower with revolutionary operator protection Technical data Power input : Single impact energy : Hammering speed under load : Speed under load : Power level I Power level II Dimensions : TE 76 TE 76-ATC Weight : TE 76 TE 76-ATC Drilling performance in medium-hard concrete Chiselling performance into medium-hard concrete 1300 W 100% : 8.3 J / 50% : 4.2 J 0-2770 blows/min. 0-200 r.p.m. 0-282 r.p.m. 497x261x115 mm 510x288x115 mm 7.0 kg 7.9 kg 20 mm dia.: 360 mm/min. 25 mm dia.: 290 mm/min. 32 mm dia.: 180 mm/min. Ordering designation operates in addition to the mechanical slip clutch: 575 cm3/min. Sensors detect jamming of the drill bit, the control unit will Item no. TE 76 230 V 334506 TE 76-ATC 230 V 334510 Includes TE 76 complete with side handle, depth gauge, dust shield, Hilti grease, cleaning cloth, impact resistant plastic tool case and operating instruction. disengage the magnetic clutch immediately and shut off the motor. Accessories for combihammers Quick-release chuck / chuck adapter Ordering designation Item no. Quick-release chuck 13 60208 for cylindrical-shank twist drill up to 13 mm diameter for drilling without hammering Chuck spindle TE-Y-BFH 263359 for quick-release chuck Chuck adapter Ordering designation TE-FY-BA-C for TE-C drill bits 10 Item no. 74068 Drilling and chiselling systems TE-YX hammer drill bits For combihammers with SDS-Max connection end Dia. (mm) Working length (mm) Ordering designation Item no. 12 12 12 14 14 15 15 16 16 16 18 18 18 20 20 20 22 22 22 24 24 25 25 25 26 28 28 30 30 32 32 32 200 400 550 200 400 200 400 200 400 800 200 400 800 200 400 800 200 400 800 200 400 200 400 800 160 200 400 250 450 250 450 800 TE-YX 12/35 TE-YX 12/55 TE-YX 12/69 TE-YX 14/35 TE-YX 14/55 TE-YX 15/35 TE-YX 15/55 TE-YX 16/35 TE-YX 16/55 TE-YX 16/92 TE-YX 18/32 TE-YX 18/52 TE-YX 18/92 TE-YX 20/32 TE-YX 20/52 TE-YX 20/92 TE-YX 22/32 TE-YX 22/52 TE-YX 22/92 TE-YX 24/32 TE-YX 24/52 TE-YX 25/32 TE-YX 25/52 TE-YX 25/92 TE-YX 26/28 TE-YX 28/32 TE-YX 28/52 TE-YX 30/37 TE-YX 30/57 TE-YX 32/37 TE-YX 32/57 TE-YX 32/92 333753 333754 333755 333756 333757 333758 333759 333760 333761 370564 339015 339016 339017 339018 339019 339020 339021 339022 339023 339024 339025 339026 339027 339028 339029 339030 339031 339032 339033 339034 339035 339036 Dia. (mm) 35 37 37 37 40 Working length (mm) 450 250 450 800 450 Ordering designation Item no. TE-YX 35/57 TE-YX 37/37 TE-YX 37/57 TE-YX 37/92 TE-YX 40/57 370846 339037 339038 339039 339040 With new soild carbide X-head Special lengths available on request TE-Y breach bits Carbide tipped, cruciform head Drilling large penetrations in concrete and masonry Dia. (mm) Working length (mm) Ordering designation 40 40 45 45 55 450 780 450 780 450 TE-Y-GB 40/59 TE-Y-GB 40/92 TE-Y-GB 45/59 TE-Y-GB 45/92 TE-Y-GB 55/59 Item no. Dia. (mm) Working length (mm) Ordering designation 55 66 66 80 780 450 780 450 TE-Y-GB 55/92 TE-Y-GB 66/59 TE-Y-GB 66/92 TE-Y-GB 80/63 Item no. Dia. (mm) Working length (mm) Ordering designation 307053 307054 307055 307056 307057 307058 307059 307060 82 82 90 90 100 125 150 170 430 170 430 310 310 310 TE-Y-BK 82/290 TE-Y-BK 82/550 TE-Y-BK 90/290 TE-Y-BK 90/550 TE-Y-BK 100/430 TE-Y-BK 125/430 TE-Y-BK 150/430 220609 220610 220611 220612 28903 Item no. 28904 28366 28421 28367 TE-Y-BK hammer core bits Metal carbide tips Hammer coring in masonry Dia. (mm) Working length (mm) Ordering designation 45 45 50 50 55 55 68 68 170 430 170 430 170 430 170 430 TE-Y-BK 45/290 TE-Y-BK 45/550 TE-Y-BK 50/290 TE-Y-BK 50/550 TE-Y-BK 55/290 TE-Y-BK 55/550 TE-Y-BK 68/290 TE-Y-BK 68/550 Item no. 307061 307062 307063 307064 307065 307066 307067 11 Drilling and chiselling systems 12 Drilling and chiselling systems Breaker TE 705 For powerful chiselling Applications Making breaches, demolition work and corrective work towards a wall; ideal for building renovation work, repairs and plumbing installations Working on surfaces and precision work Technical data Power input : Single impact energy : Hammering speed under load : Dimensions : Weight : Chiselling performance in medium-hard concrete : 1030 W 4.3 / 8.5 Joules 1890 / 2670 blows/min. 515x115x215 mm 6.5 kg 500 cm3/min. Ordering designation Item no. TE 705 230 V 313268 Includes TE 705 complete with side handle, Hilti grease, cleaning cloth, impact resistant plastic tool case and operating instruction. Breaker TE 805 Powerful, portable and reliable Applications Removal and demolition work with concrete, masonry, stone and asphalt Technical data Power input : Single impact energy : Hammering speed under load : Dimensions : Weight : Chiselling performance in medium-hard concrete : 1350 W 17 Joules 2000 blows/min. 590x122x230 mm 9.7 kg 1200 cm3/min. Ordering designation Item no. TE 805 230 V 255166 Includes TE 805 complete with side handle, Hilti grease, cleaning cloth, impact resistant plastic tool case and operating instruction. Breaker TE 905-AVR Maximum power, minimum vibration Applications Chiseling and demolition work on concrete, masonry, stone and asphalt Technical data Power input : Hammering speed under load : Single impact energy : Dimensions (LxWxH) : Weight of machine : Typical chiselling performance on medium-hard concrete : Ordering designation Vibration reduction of about 50% by the revolutionary AVR system 1600 W 2200 blows/min. 20 Joules 680x110x180 mm 11.3 kg 1300 cm3/min. Item no. TE 905 230 V 376560 Includes TE 905 complete with side handle, Hilti grease, cleaning cloth, impact resistant plastic tool case and operating instruction. 13 Drilling and chiselling systems Chisel TE-Y for TE 56/ TE 76/ TE 505/ TE 705 Features / customer benefits Hard metal: Durable metal: for long life expectancy for long life expectancy connection end and impact damping for maximum life expectancy and performance of Hilti tools Dust guard: Two different types of metal and dust guard 1 1 Hard metal 2 Durable metal 3 Dust guard Pointed chisels, demolition (hard material) Total length (mm) Ordering designation 280 360 500 TE-Y-KSM 28 TE-Y-KSM 36 TE-Y-KSM 50 Item no. 2708 204333 204334 Narrow-flat chisels, demolition (soft material), wide channels Total length (mm) Blade width (mm) Ordering designation 280 360 500 max. 26 max. 26 max. 26 TE-Y-KFM 28 TE-Y-KFM 36 TE-Y-KFM 50 Item no. 2709 204336 204337 TE-SP polygon chisels for TE 805/ TE 905-AVR No sharpening due to new innovative design Pointed chisel Overall length (mm) Ordering designation 360 500 700 TE-SP-SM 36 TE-SP-SM 50 TE-SP-SM 70 Item no. 376492 376493 376494 Flat chisel Overall length (mm) 360 500 700 Cutting edge width(mm) max.26 max.26 max.26 Ordering designation TE-SP-FM 36 TE-SP-FM 50 TE-SP-FM 70 Item no. 376495 376496 376497 Wide-flat chisel Overall length (mm) 360 500 360 500 360 500 14 Cutting edge width(mm) max.50 max.50 max.80 max.80 max.26 max.26 Ordering designation TE-SP-SPM 5/36 TE-SP-SPM 5/50 TE-SP-SPM 8/36 TE-SP-SPM 8/50 TE-SP-SPM 12/36 TE-SP-SPM 12/50 Item no. 376498 376499 376500 376501 376502 376503 2 3 Diamond systems DD EC-1 Diamond coring system Hilti TopSpin technology for top productivity Applications Drills anchor holes or through holes of 8-35 mm diameter quickly and precisely Drills with little vibration and low noise - ideal for renovation and conversion work Sensitive environments: drills without dust and leaves no slurry behind - practically no cleaning up necessary Drilling depth up to 300 mm Mobility ensured due to independence from external water supplies DD EC-1 Motor unit 1 Ordering designation Item no. DD EC-1 motor unit 230 V 337333 Includes DD EC-1 complete with water collector system, 5-meter supply cord with built - in ground fault interupter (PRCD), depth gauge, Hilti spray, cleaning cloth, impactresistant plastic toolbox and operating instructions. DD-REC 1 Water recycling unit Ordering designation 2 Technical data Power input : 1450 W Weight : 5.7 kg Dimensions : 423x108x195 mm Minimum distance between wall and hole drilled : 36 mm No load speed : 9100 r.p.m. Max. permitted water supply pressure : 6 bar Slip clutch release torque : 13 Nm Power input : Weight (without water) : Water filling volume : Max. number of holes drilled before refilling : Dimensions (without trolley) : Max. water pressure : 3 Item no. 3 DD-CR 1 drill stand 337350 Includes DD-REC 1 complete with removable trolley, 5metre hose set (no electric supply cord), cleaning pad and operating instructions. 2 DD-REC 1 filter 338524 Technical data DD-CR 1 Drill stand Ordering designation Item no. 1 DD-REC 1 230 V 376281 300 W 25 kg 4-13 I Approx. 50 500x330x420 mm <6 bar DD-C Core bits/Core-breaking tools Equipped with water collector ring (seal) T2 core bits T4 core bits Core bit dia. (mm) Working length (mm) Ordering designation Item no. Ordering designation 8 10 12 14 15 16 16 18 18 20 20 22 24 25 28 30 32 35 70 150 150 150 150 150 300 150 300 150 300 300 300 300 300 300 300 300 DD-C 8/ 70 T2 DD-C 10/150 T2 DD-C 12/150 T2 DD-C 14/150 T2 DD-C 15/150 T2 DD-C 16/150 T2 DD-C 16/300 T2 DD-C 18/150 T2 DD-C 18/300 T2 DD-C 20/150 T2 DD-C 20/300 T2 DD-C 22/300 T2 DD-C 24/300 T2 DD-C 25/300 T2 DD-C 28/300 T2 DD-C 30/300 T2 DD-C 32/300 T2 DD-C 35/300 T2 336885 336887 336889 336891 336895 336897 336898 336899 336900 336905 336906 336909 336911 336912 336914 336916 336917 336920 DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C DD-C 14/150 15/150 16/150 16/300 18/150 18/300 20/150 20/300 22/300 24/300 25/300 28/300 30/300 32/300 35/300 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 Core-breaking tools Item no. 336855 336859 336861 336862 336863 336864 336869 336870 336873 336875 336876 336878 336880 336881 336884 Ordering designation DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB DD-CB 12 14 15 16 16 18 18 20 20 22 24 25 28 30 32 35 Item no. 338346 338348 338350 338351 338351 338352 338352 338355 338355 338357 338359 338360 338362 338364 338365 338368 T2: For concrete of low to medium abrasiveness, natural stone and clinker. Concrete with medium to low reinforcement content. T4: For concrete of medium to high abrasiveness and brick. Concrete with medium to high reinforcement content. 15 Diamond systems DD 130 Diamond coring system Applications Precision holes in reinforced concrete, natural stone, masonry and asphalt; for cables, pipes, ventilation, test cores and anchors Advantages of motor unit Can be used both handheld and on a rig Can be used for both wet and dry diamond coring without modification Safety features include: safety slip clutch; ground fault interrupter (PRCD), electronic speed regulator; overload current regulator and integrated starting current regulator; thermal motor protector Easy to use and understand Leveling bubble for accurate hole-starting Quick-lock connection end for fast insert and removal of core bits Compatible with innovative Hilti DD-B and PCD core bits Advantages of drill stand Comfortable drilling posture maintained throughout coring process Quick-lock motor mount mechanism for simplicity and speed Cores at angles up to 45 degrees quickly and easily and without the need for any additional tools Suitable for anchor, vacuum and brace fastening without any modification or alteration Provides easy access for coring in corners and against walls Technical data Voltage : Nominal power : Nominal current : Weight : 230 V 1900 W 8.7 A 7.7 kg 13 kg DD 130 tool DD 130 rig Speed (no load)/Diameter range : wet 1st gear 780 r.p.m. 57-152 mm 2nd gear 1400 r.p.m. 28-52 mm 3rd gear 2600 r.p.m. 12-25 mm dry 1st gear 780 r.p.m. 122-162 mm 2nd gear 1400 r.p.m. 67-122 mm 3rd gear 2600 r.p.m. 12-62 mm Chuck type : Quick-release BI+ Min. access to walls : 40 mm from the center of the hole Min. access to corners : 57 mm from the center of the hole Max. stroke (stationary) : 430 mm DD 130 Tool Ordering designation Item no. DD 130 motor unit 230 V 370455 Includes DD 130 complete with impact-resistant transport case, safety glasses, Hilti spray and cleaning cloth. DD 130 Rig Ordering designation DD 130 rig 16 Item no. 370461 Feature Wet and dry for more flexibility The Hilti DD 130 can be used for wet or dry drilling in a wide variety of materials without the need for any modification or change of parts. Diamond systems DD 250-E Diamond coring machine Applications Precise holes in the 25-250 mm diameter range in steel-reinforced concrete, natural stone, synthetic stone and asphalt. Making breaches for supply and disposal lines Making breaches for fresh and exhaust air ducts Drilling perforations Drilling holes for house / building supply lines Removing test cores Technical data Voltage : Power : Current : No-load speed : 1st speed : 275 r.p.m. 2nd speed : 450 r.p.m. 3rd speed : 950 r.p.m. 4th speed : 1800 r.p.m. Weight : 230 V 2400 W 11 A Core bit diameter range 172-250 mm 92-102 mm 40-102 mm 25-56 mm 17 kg DD 250-E Standard set Ordering designation DD 250-E motor unit 230 V Claming piece DD-CP-M Eccentric pin DD-EP-ML Chuck body DD-C-BU Stand baseplate DD-BA-6 Cone DD-BCQ-ML Track DD-R100-M Housing DD-CA-M Wrench V007 Jack screw KPL Item no. 236086 235928 232244 232234 232218 232215 232211 232207 221202 220941 Features: A large variety of uses and simple handling due to a modular design. 17 Diamond systems Hilti DD-B Series: The new line of core bits Simply quicker for greater performance Quicker Coring up to 70 percent faster than comparable core bits. Retipping of worn 35 to 250 mm diameter core bits in only 20 minutes with the unique Hilti change module. Stronger Laser-welded diamond segments ensure maximised joint quality for a 30 percent stronger hold than conventionally brazed segments. Cutting-edge manufacturing processes guarantee top quality and long life expectancy of each core bit. Simple Quick connection ends (BI+ and BU) ensure a simple core bit change without the use of a tool, and optimise power transmission. The more reinforcement in concrete, the better the performance. The new Hilti DD-B series cut through rebars up to 70 percent faster. Power Due to the innovative diamond matrix, coring is amazingly quick and the life expectancy extremely long. Laser-welded diamond segments give you the assurance of top joint quality. Flexible You can drill through many grades of reinforced concrete, marble, sandstone, natural stone and tiles using one core bit throughout. Hilti connection ends for core bits Ordering designation Connect end BI+ Connect end BU Item no. 236120 236122 BI+ BU The new core bits Hilti specifications P2 core bit: For concrete of low to medium abrasiveness, natural stone and clinker. Concrete with medium to low reinforcement content. P4 core bit: For concrete of medium to high abrasiveness and brick. Concrete with medium to high reinforcement content. P6 core bit: For concrete high abrasiveness. Concrete with flint aggregates. P130 core bit: For DD 130 diameter 102-152 mm. 18 Diamond systems DD-B Core bits with connection end P2* Dia. (mm) Working length (mm) 12 14 16 18 20 22 24 25 25 28 28 30 30 32 32 35 37 40 42 47 320 320 320 320 320 320 320 320 430 320 430 320 430 320 430 430 430 430 430 430 P4* With BI+ With BU Ordering designation Item no. Item no. Ordering designation DD-B.. 25/320 P2 DD-B.. 25/430 P2 DD-B.. 28/320 P2 DD-B.. 28/430 P2 DD-B.. 30/320 P2 DD-B.. 30/430 P2 DD-B.. 32/320 P2 DD-B.. 32/430 P2 DD-B.. 35/430 P2 DD-B.. 37/430 P2 DD-B.. 40/430 P2 DD-B.. 42/430 P2 DD-B.. 47/430 P2 370244 370246 370248 370249 370251 370252 370253 370254 370255 370256 370257 370260 370261 370264 370265 370266 370267 370270 370271 370272 370273 370274 DD-B.. 12/320 P4 DD-B.. 14/320 P4 DD-B.. 16/320 P4 DD-B.. 18/320 P4 DD-B.. 20/320 P4 DD-B.. 22/320 P4 DD-B.. 24/320 P4 DD-B.. 25/320 P4 DD-B.. 25/430 P4 DD-B.. 28/320 P4 DD-B.. 28/430 P4 DD-B.. 30/320 P4 DD-B.. 30/430 P4 DD-B.. 32/320 P4 DD-B.. 32/430 P4 DD-B.. 35/430 P4 DD-B.. 37/430 P4 DD-B.. 40/430 P4 DD-B.. 42/430 P4 DD-B.. 47/430 P4 With BI+ With BU Item no. Item no. 370295 370297 370299 370300 370302 370304 370305 370306 370308 370310 370311 370313 370314 370315 370316 370317 370318 370319 370322 370323 370326 370327 370328 370329 370332 370333 370334 370335 370336 DD-B Core bits without connection end Dia. (mm) Working length (mm) Ordering designation 52 57 62 67 72 77 82 87 92 102 112 122 132 142 152 162 182 202 205 225 250 300 350 400 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 430 500 500 500 DD-B 52/430 P.. DD-B 57/430 P.. DD-B 62/430 P.. DD-B 67/430 P.. DD-B 72/430 P.. DD-B 77/430 P.. DD-B 82/430 P.. DD-B 87/430 P.. DD-B 92/430 P.. DD-B 102/430 P.. DD-B 112/430 P.. DD-B 122/430 P.. DD-B 132/430 P.. DD-B 142/430 P.. DD-B 152/430 P.. DD-B 162/430 P.. DD-B 182/430 P.. DD-B 202/430 P.. DD-B 205/430 P.. DD-B 225/430 P.. DD-B 250/430 P.. DD-B 300/500 P.. DD-B 350/500 P.. DD-B 400/500 P.. P2* P4* P6* P130* Item no. Item no. Item no. Item no. 369890 369891 369892 369893 369894 369895 369896 369897 369898 369899 369900 369901 369902 372766 369903 369904 369905 369906 369907 369908 369909 369910 369911 369912 369913 369914 369915 369916 369917 369918 369919 369920 369921 369922 369923 369924 369925 372767 369926 369927 369928 369929 369930 369931 369932 - 369933 369934 369935 369936 369937 369938 369939 369940 369941 369942 369943 369944 369945 369946 369947 369948 369949 369950 369951 369952 - 371523 371524 371525 371526 371527 - * See details of P2, P4, P6, P130 core bit’s specifications on page 18 19 Diamond systems DD-CM Change modules P2* P4* P6* Dia. (mm) Ordering designation Item no. Item no. Item no. 35 37 40 42 47 52 57 62 67 72 77 82 87 92 102 112 122 132 152 162 182 202 225 250 DD-CM 35 DD-CM 37 DD-CM 40 DD-CM 42 DD-CM 47 DD-CM 52 DD-CM 57 DD-CM 62 DD-CM 67 DD-CM 72 DD-CM 77 DD-CM 82 DD-CM 87 DD-CM 92 DD-CM 102 DD-CM 112 DD-CM 122 DD-CM 132 DD-CM 152 DD-CM 162 DD-CM 182 DD-CM 202 DD-CM 225 DD-CM 250 369953 369954 369955 369956 369957 369958 369959 369960 369961 369962 369963 369964 369965 369966 369967 369968 369969 369970 369971 369972 369973 369974 369975 369976 369977 369978 369979 369980 369981 369982 369983 369984 369985 369986 369987 369988 369989 369990 369991 369992 369993 369994 369995 369996 369997 369998 369999 370000 370001 370002 370003 370004 370005 370006 370007 370008 370009 370010 370011 370012 370013 370014 370015 370016 370017 370018 370019 370020 370021 370022 370023 370024 P130* Item no. 371528 371529 371530 371531 371532 - Remove worn change module with hacksaw. Heat up parts with brazing torch and remove them. Clean old brazing alloy off interface using wire brush. Obtain optimal brazed joint by coating cut surface and change module with flux (available from Hilti warehouse). * See details of P2, P4, P6, P130 core bit’s specifications on page 18 20 Heat up flux with brazing torch and braze on new change module. Diamond systems Hilti DG 150 diamond grinding system Revolutionary dry diamond grinding system for exceptionally high material removal performance and long life expectancy. Keeps dust to an absolute minimum thanks to the specially developed dust hood and new Hilti VCD 50 dry vacuum cleaner Maximum material removal thanks to finetuned diamond cup wheels for every application New SR motor technology for long life Applications Dry grinding coated and uncoated mineral materials - removal of remains of coatings and tile adhesives on floors and balconies - high rate of removal and perfect finish on concrete and screed - removal of thin paint coating on hard cement rendering Technical data (DG 150 with DPC 20) Nominal voltage Nominal current Power input Power output No-load speed Setting no. 1 Setting no. 2 Weight (without DPC 20) Cup wheel diameter Electrical protection 230 V 8.8 A 2100 W 1500 W 4700 r.p.m. 6600 r.p.m. 4.1 kg 150 mm dia. Protection class II (double insulated) Quick stop in two seconds or less after switching off, restart interlock, adjustable grip, dust hood with opening section and adjustable in height DG 150 diamond grinder Ordering designation Item no. DG 150 diamond grinding system, 230 V complete 369391 Includes DG 150 with DPC20 in Hilti toolbox, with 1 pair of goggles, 1 wrench, 1 clamping flange, 1 clamping screw (M13), 1 operating instructions Diamond cup wheels for the Hilti DG 150 (dry grinding applications) Cup wheel: 150 mm dia., mounting hole: 19 mm dia. Colour code No. of segments Package contents Ordering designation Item no. C1 DG-CW 150/6” C1 369414 7 1 For concrete D1 DG-CW 150/6” D1 369417 7 1 For fine finishing on concrete, rounding edges C2 DG-CW 150/6” C2 369415 7 1 For flint concrete, hard rock A1 DG-CW 150/6” A1 369413 7 1 For screed, tile adhesive B1 DG-CW 150/6” B1 369418 16 1 For removing coatings on concrete, rendering and screed VCD 50 dry vacuum cleaner, complete Ordering designation C1 D1 C2 A1 B1 Item no. VCD 50 dry vacuum cleaner, 230 V complete 369408 in cardboard box, with 1 filter, 1 hose, 1 tapered adaptor, 1 dust bag Spare parts for the VCD 50 vacuum cleaner Ordering designation Filter insert, dust class L For the VCD 50 Package contents 1 Item no. 371145 Filter insert 21 Diamond systems D-LP32/ DS-TS32 modular wall saw system, adaptable to individual requirements Applications Universal system for sawing specialists and service contractors: Sawing, coring and wire sawing Breaches and openings for windows and doors etc. Concrete demolition and remedial work Powerful, quick and convenient Materials Concrete and reinforced concrete, cutting to a depth of 73 cm Masonry and stone Convenient controls Digital remote control for greater convenience, safety and efficiency Operating status indicators Fault indicators For all applications Powerful drive Compact saw head Saw arm with built-in hydraulic motor Central cooling water supply for motor and saw blade Saw arm with synchronised blade guard pivots 360 in both directions Intelligent advance HTC for maximum power transmission and highest cutting performance Semi-automatic advance, independent of the material being cut Cam-action roller system for rapid saw head mounting D-LP 32 hydraulic unit DS-TS 32 saw head Technical data Hilti motor : Max. operating pressure : Max. oil flow rate : Dia. range, single gear : Max. cutting depth : Weight : Variable speed : Technical data Rated power input at 63 A : 43 kW Nominal power : 32 kW Nominal voltage : 400V~50Hz 3 P+PE Fuse rating, min : 32 A Fuse rating, max : 63 A Max. operating pressure : 200 bar Oil flow rate : 40-100 I/min Weight incl. oil : 220 kg Digital electronic remote control : 24 V To achieve best possible cutting performance, the Hilti Traction Control System compares the calculated value, up to 100 times per second, with the mains power limiting value, set by the operator on the digital remote control unit. 54 cm3 200 bar 100 I/min. 600-1600 mm 73 cm 36 kg 400-900 r.p.m. 1 D-LP 32 hydraulic unit Ordering designation D-LP 32 (400V) incl. RC-LP 32 remote control unit D-RC-LP 32 remote control unit (replacement) D-RC-ext. extension cable 10 m, for remote control unit Qty. Item no. 1 1 1 369313 369312 334178 Ordering designation DS-TS32-54 cm3 saw head DS-TS 30 can be converted to DS-TS 32 at Hilti repair centres. Qty. Item no. 1 369315 Hoses for connecting D-LP32 hydraulic unit to DS-TS32 saw head and extension DS-PH34-10 hydraulic hose DS-FH4/14-10 hydraulic hose set 22 3 2 DS-TS 32 saw head Ordering designation 1 2 Qty. 2 1 Item no. 221128 221129 1 2 3 Diamond systems DS-BG blade guard for normal / corner cutting Ordering designation Accessory TS30 TS32 Qty. DS-BG 8* blade guard DS-BG 9* blade guard DS-BG 10* blade guard DS-BG 12* blade guard DS-BG 16* blade guard 1 1 1 1 1 Item no. 370474 370476 370477 370478 333883 *Corresponds to maximum saw blade diameter (x100) DS-BG blade guard for flush cutting Ordering designation Accessory TS30 TS32 Qty. DS-BGF 8* blade guard DS-BGF 9* blade guard DS-BGF 10* blade guard DS-BGF 12* blade guard DS-BGF 16* blade guard 1 1 1 1 1 Item no. 370479 370480 370481 370482 256237 *Corresponds to maximum saw blade diameter (x100) D-R..L rails Accessory TS30 TS32 Ordering designation Qty. D-R 50 L rail D-R 100 L rail D-R 150 L rail D-R 200 L rail D-R 230 L rail 1 1 1 1 1 Item no. 310335 310336 310337 310338 310339 *Each D-R..L rail is supplied complete with end stops. -PLEASE ASK FOR DELIVERY DETAILS. DS-B-H (optimised for 19-35 kW machines) HI CS-H specification for fast cutting in reinforced concrete with soft aggregate and low abrasiveness Diameter (mm) Segment width (mm) Segment height (mm) Segment length (mm) No. of segments 600 700 750 800 900 1000 1200 1500 1600 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 10 10 10 10 10 10 8 8 8 50 50 50 50 50 50 50 50 50 31 37 39 42 47 50 58 72 75 Ordering designation DS-B 600/HI CS-H DS-B 700/HI CS-H DS-B 750/HI CS-H DS-B 800/HI CS-H DS-B 900/HI CS-H DS-B 1000/HI CS-H DS-B 1200/HI CS-H DS-B 1500/HI CS-H DS-B 1600/HI CS-H Item no. 339832 339833 339834 339835 339836 339837 339838 339830 339831 HI CM-H specification for normal speed with long life in reinforced concrete with a high amount of quart sand Diameter (mm) Segment width (mm) Segment height (mm) Segment length (mm) No. of segments Ordering designation 600 700 750 800 800 900 1000 1200 4.5 4.5 4.5 4.5 5 4.5 4.5 4.5 10 10 10 10 10 10 10 8 50 50 50 50 50 50 50 50 31 37 39 42 42 47 50 58 DS-B 600/HI CM-H DS-B 700/HI CM-H DS-B 750/HI CM-H DS-B 800/HI CM-H DS-B 800/5/HI CM-H DS-B 900/HI CM-H DS-B 1000/HI CM-H DS-B 1200/HI CM-H Item no. 339822 339823 339824 339825 339826 339827 339828 339829 HI CH-H specification for normal speed with long life in reinforced concrete with hard aggregate and high abrasiveness Diameter (mm) Segment width (mm) Segment height (mm) Segment length (mm) No. of segments 600 800 900 1000 1200 4.5 4.5 4.5 4.5 4.5 10 10 10 10 8 50 50 50 50 50 31 42 47 50 58 PLEASE ASK FOR DELIVERY DETAILS. Ordering designation DS-B 600/HI CH-H DS-B 800/HI CH-H DS-B 900/HI CH-H DS-B 1000/HI CH-H DS-B 1200/HI CH-H Mounting bore and drive screw spacing Standard version: Item no. 374074 374075 374076 374077 374078 Other versions: 6 countersunk holes for flush-cutting (suitable for use with the Hilti DS-FCA-110 flush-cutting flange and DL-FA 30-110) Available to order Ø110 7 0H Ø6 23 Direct fastening systems DX 450 Powder-actuated fastening tool Sprinkler pipes to steel or concrete Universal fastenings to steel: angles,rails etc. For fastening wall and roof liner panels and floor decking to structural steel from 3-6 mm thick Fastenings in damp, corrosive surroundings DX 460 universal powder actuated tool Universal fastenings to concrete and steel: concrete forms, underfloor trunking, installation strips/straps, sheet-metal brackets/angles etc. Uses: Making fastenings of many kinds with nails up to 72 mm long (97 mm wide pre-drive) to steel, concrete and masonry materials Features: Automatic cartridge feed, thus no wasted cartridges Electrical installation clamps/clips: lamps, lighting, conduits Universal piston Simple cleaning and servicing Increased performance and reliability New and improved cartridge tool with less recoil for operator comfort Electrical clips/clamps, light brackets, threaded plates, rails to steel GX 100 gas driven fastening system This is the right system for interior finishing top performance in hard and old concrete, as well as standard concrete and steel. Pipes, electrical clips/clamps, lamps, switchboxes etc. to concrete 24 Direct fastening systems DX 460 Powder-actuated fastening tool Technical data Weight : 3.53 kg incl.magazine Length : 460 mm Magazine capacity : nails in magazine strips of 10 lengths 14-72 mm Cartridge : 6.8/11 M, in magazine strips of 10, 4 power levels (green, yellow, red, black) Ordering designation Item no. DX 460 371680 Includes DX 460 complete with accessories (cleaning brushes, safety goggles, cleaning cloth, Hilti spray and operating instruction). Spare parts X-460-F8 Description Ordering designation Magazine For magazined nails up to 72 mm Fastener guide Standard For better accessibility, 15 mm narrow For better accessibility, 10 mm narrow For nails with 12 mm diameter steel washer With spall stop for 6 and 8 mm threaded studs For 10 mm threaded studs and nails With spall stop for 10 mm threaded studs For X-IE insulation fasteners Piston Standard piston, for X-DNI, X-EDNI, X-ZF, X-FS, X-CR, For X-DAK nails, 6 and 8 mm threaded studs For X-AL nails For overdriving nails For X-IE insulation fasteners Stabilizer To support square pressing of the tool against the surface Buffer Item no. MX72 370844 X-460-F8 X-460-F8N15 X-460-F8N10 X-460-F8S12 X-460-F8SS X-460-F10 X-460-F10SS X-460-FIE 373313 373314 373315 373317 373318 373319 373320 373321 X-460-P8 373297 X-460-P8AL X-460-P8W X-460-PIE 373299 373298 373301 X-460-STAB X-460-B 373322 373330 X-460-F8N15 MX72 X-460-F8N10 X-460-F8S12 X-460-F10 X-460-F10SS X-460-F8SS X-460-FIE X-460-P8 X-460-P8AL X-460-P8W X-460-PIE X-460-B X-460-STAB DX 450 Powder-actuated fastening tool Technical data Weight : Length : Cartridge : Ordering designation 3.2 kg 350 mm 6.8/11 M, in magazine strips of 10, 3 power levels (yellow, red, black) Item no. DX 450 712 Includes DX 450 complete with accessories (cleaning brushes, safety goggles, cleaning cloth, Hilti spray and operating instruction). Spare parts Ordering designation Item no. 45/NK piston Stop ring Retaining ring 748 855 856 12 mm Piston 25 Direct fastening systems GX 100 gas driven fastening system Technical data Weight : Nail Length : Tool dimensions : 4.15 kg 18-39 mm. 425 mm. x172 mm. x 370 mm. Ordering designation Item no. Gas Actuated Tool GX 100 Nail Magazine X-GM 40 Support X- 100 SL Sleeve X-100 TN 339465 378586 378587 378588 Includes GX 100 complete with accessories, operating instruction. Top performance and no battery to charge: Up to 1000 repetitive fastenings per hour with a magazine for 40 nails Covers all interior finishing jobs: collated nails from 14-39 mm for concrete, steel, block, plastered brick and limestone GX-100 X-100 SL X-GM 40 X-100 TN Gas can for 750 high quality fastenings: Easy gas can loading Odorless gas Repetitive fastenings for every base material 40 nail magazine: Simple to load, faster to work with X-EGN 14MX Base material: Steel Length: 14 mm X-GHP 18MX Base material: Hard concrete Length: 18 mm X-GN 27MX Base material: Concrete, block, limestone, plastered brick Length: 27 mm X-GN 32MX Base material: Concrete, block, limestone, plastered brick Length: 32 mm 26 X-GN 20MX Base material: Concrete, plastered brick X-GN 39MX Base material: Concrete, block, limestone, plastered brick Length: 39 mm Direct fastening systems Cartridges 6.8/11 M X-EDNI Nail Booster for DX 460, DX 450, DX-A40, DX-A41 Ordering designation Power level Package contents 6.8/11 M white 6.8/11 M green 6.8/11 M yellow 6.8/11 M red Extra Light Light Medium Heavy 100 100 100 100 Fastening to steel up to 4500 ksc tensile strength for DX 460, DX-A40, DX-A41 Item no. 333318 50351 50352 50353 X-CF Nail Fastening to concrete up to 300 ksc for DX 460, DX-A40, DX-A41 Package contents Item no. X-EDNI 12 P8 X-EDNI 16 P8 X-EDNI 19 P8 X-EDNI 22 P8 100 100 100 100 34345 34536 34537 34538 Fastening to concrete for DX 450 shank dia. 3.7 mm Ordering designation Package contents Item no. X-CF X-CF X-CF X-CF X-CF X-CF X-CF 1000 1000 1000 1000 1000 1000 1000 34487 34488 34489 34490 34491 34492 34494 P8 P8 P8 P8 P8 P8 P8 Ordering designation NK Nail shank dia. 3.5 mm 27 32 37 47 52 62 72 shank dia. 3.7 mm X-DNI Nail Fastening to concrete up to 400 ksc for DX 460, DX-A40, DX-A41 Ordering designation Package contents Item no. NK NK NK NK NK NK NK NK 100 100 100 100 100 100 100 100 41057 41058 41059 41060 41061 41062 41064 41065 22 27 32 37 42 47 62 72 S12 S12 S12 S12 S12 S12 S12 S12 ENK Nail shank dia. 3.7 mm Fastening to steel for DX 450 Ordering designation Package contents Item no. X-DNI 22 P8 X-DNI 27 P8 X-DNI 32 P8 X-DNI 37 P8 X-DNI 42 P8 X-DNI 47 P8 X-DNI 52 P8 X-DNI 57 P8 X-DNI 62 P8 X-DNI 72 P8 100 100 100 100 100 100 100 100 100 100 34351 34352 34353 34354 34355 34357 34360 34361 34363 34364 shank dia. 3.7 mm Ordering designation Package contents Item no. ENK 16 S12 ENK 19 S12 ENK 22 S12 100 100 100 41503 41505 41507 GAS CAN Fastening to steel and concrete for GX 100 Ordering designation M6/M8 Threaded stud - 8 mm washer Package contents GC 11 12 shank dia. 3.7 mm GAS Nail Fastening to concrete for DX 460, DX-A40, DX-A41 338862 Fastening to steel and concrete for GX 100 Ordering designation Ordering designation Package contents X-M6-11-22 X-M6-11-27 X-M6-20-22 X-M6-20-27 X-M8-15-27 X-M8-20-27 100 100 100 100 100 100 FP8 FP8 FP8 FP8 P8 P8 Item no. Item no. 306076 306077 306078 306079 306092 306095 X-GHP 18MX EGN 14MX GN 20MX GN 27MX GN 32MX GN 39MX X-GHP 18MX GN 27MX Package contents Item no. 750 750 750 750 750 750 340228 340230 340231 340232 340233 340234 EGN 14MX GN 20MX GN 32MX GN 39MX 27 Direct fastening systems M6/M8 Threaded stud - 12 mm washer Fastening to concrete for DX 450 shank dia. 3.7 mm Ordering designation Package contents M6-11-22 D12 M6-11-27 D12 M6-20-22 D12 M6-20-27 D12 M8-15-27 D12 M8-20-27 D12 100 100 100 100 100 100 Item no. 306054 306055 306059 306060 306097 306100 EM6/EM8 Threaded stud Fastening to steel for DX 460, DX-A40, DX-A41, D450 shank dia. 3.7 mm Ordering designation Package contents EM6-11-12 FP8 EM6-20-12 FP8 EM6-11-12 D12 EM6-20-12 P12 EM8-11-12 P8 EM8-15-12 P8 100 100 100 100 100 100 Item no. 306109 306111 306105 306113 306134 306136 X-FCM Grating fastening disc For a fastening height of 25-50 mm X-CC Ceiling clip Ordering designation shank dia. 3.7 mm X-FCM-F25/30 X-FCM-F35/40 X-FCM-F45/50 X-FCM-R25/30 X-FCM-R35/40 X-FCM-R45/50 Fastening to steel, concrete for DX 460, DX-A40, DX-A41 Ordering designation Package contents X-CC EDNI 16 P8 X-CC DNI 32 P8 100 100 Hot-dipped galvanised Stainless steel Package contents 200 200 200 200 200 200 Item no. 247170 247171 247172 247181 247182 247183 Item no. 299936 299929 X-FCP Floorplate fastening disc For a fastening height of 5-13 mm X-CR Stainless steel nail Fastening to concrete and steel for DX 460, DX-A40, DX-A41 shank dia. 3.7 mm Ordering designation X-CR 16 P8 X-CR 18 P8 X-CR 21 P8 Item no. 247356 247357 247358 Ordering designation Hot-dipped galvanised Stainless steel X-FCP-F5/10 X-FCP-R5/10 X-FCP sealing ring Package contents 200 200 200 Item no. 308859 308860 308856 X-CR M8 Stainless steel threaded stud For DX 460 shank dia. 4.0 mm X-CRM8-9-12P8 Ordering designation Package contents X-CRM8-9-12 P8 1) X-CRM8-15-12 P81) X-CRM8-15-12 P122) 100 100 100 1) 2) 28 For the DX A40 grating fastening tool For the DX 450 grating fastening tool X-CRM8-15-12P8 Item no. 308857 255979 247517 Anchoring systems 29 Anchoring systems HIT-HY 150 Injection adhesive Concrete Small edge distance / spacing Corrosion resistance High corrosion resistance Fire resistance Hilti Anchor programme Use Concrete Various fastener options HAS and HIS-N anchor rods Rebars (not in Hilti product range) Ordering designation Package contents Foil pack HIT-HY 150/330/2 Foil pack HIT-HY 150/500/2 Jumbo pack HIT-HY 150 1100/1 1 1 1 Item no. 330ml 500ml 1100ml 315482 338973 256073 Temperature of the base meterial Working time in which rod can be inserted and adjusted, Curing time before anchor can be fully loaded, °C -5 0 +5 +20 +30 +40 tgel tcure 90 min 45 min 25 min 6 min 4 min 2 min The foil pack temperature must be at least +5°C. HIT-HY 150 with HAS rod 6 3 1.5 50 40 30 hours hours hours min min min Basic loading data (for a single anchor) : HIT-HY 150 with HAS, HAS-E rod Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2 Setting details Note: Edge distance and spacing influence are not considered. Contact Hilti engineering for exact calculation of your specific application. Jumbo pack Poil pack Setting operations Drill hole. 30 Clean hole. Inject mortar. Insert rod. Wait for curing. Apply tightening torque. Anchoring systems HIT-HY 150 with rebar Recommended load : Frec [kN] Rebar, Hole diameter, D (mm) D D D D D D D 8 12 10 14 12 16 14 18 16 22 20 28 25 32 Installed Length, lb, inst (mm) 100 120 140 160 9.6 11.4 11.4 Frec V(ml) 8 10 12 Frec 10.4 12.5 14.6 16.7 V(ml) 10 16 12 14 13.4 15.6 17.8 Frec 18 14 16 V(ml) Frec 16.5 18.9 V(ml) 21 18 Frec 20.9 V(ml) 37 Frec NOT RECOMMENDED V(ml) Frec V(ml) 180 200 220 240 300 350 400 450 500 600 700 800 850 119 17.9 18 20.0 21 21.3 24 23.5 42 17.9 20 22.3 23 23.6 26 26.1 46 29.5 77 172 24.5 25 26.0 29 28.7 51 32.4 85 25.7 27 28.3 31 31.3 55 35.3 93 Condition: Concrete strength (Cylinder) : fck (Not less than 20 N/mm2) Rebar yield strength (SD40) : fyk Partial safety factor: 280 260 Length to develop yield, lb (mm) Steel = Concrete/HY 150 = Variable action = 25.7 32 33.1 36 36.6 64 41.2 100 108 40.9 44.1 104 112 25.7 30 30.7 34 33.9 60 38.3 FULL STEEL UTILIZATION 35.0 39 39.2 69 44.2 116 47.2 120 231 35.0 45 297 45.7 45.7 45.7 80 92 103 51.5 58.9 66.3 71.5 71.5 135 154 173 192 231 55.1 63.0 70.8 78.7 94.5 110.2 111.7 111.7 140 160 180 200 240 280 320 340 350 485 709 = 20 N/mm2 (~200 ksc) = 400 N/mm2 (~4000 ksc) 1.15 1.5 1.5 Note: Contact Hilti engineering for exact calculation of your specific application. Setting operations 31 Anchoring systems HIT-RE 500 Injection adhesive Concrete Small edge distance / spacing High corrosion resistance Corrosion resistance Hilti Anchor programme Use Concrete Natural stone Features injection system with high loading capacity good performance in diamond drilled hole good performance in water saturated concrete larger diameter application long working time at elevated temperatures odourless mortar no expansion forces in base material small edge distance and anchor spacing clean and easy handling Various fastener options Large diameter, deeply-set rebars (rebars not in Hilti product range) HAS and HIS-N anchor rods Ordering designation Package contents Foil pack HIT-RE 500/330/1 Foil pack HIT-RE 500/500/1 Jumbo pack HIT-RE 500/1100/1 Item no. 1 330ml 1 500ml 1 1100ml 337109 369109 337110 Basic loading data (for a single anchor) : HIT-RE 500 with HAS, HAS-E rod steel grade 5.8 for M8-M24 sizes and steel grade 8.8 for M27-M39 Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Temperature of the base material: cí cí cí cí cí cí Working time in which Curing time before anchor anchor can be inserted can be fully loaded and adjusted 40 12 min. 4 hours 30 20 min. 8 hours 20 30 min. 12 hours 10 2 hours 24 hours 0 3 hours 50 hours -5 4 hours 72 hours Contact your Hilti advisory service. Iess than -5 The foil pack temperature must be at least +10 cí cí HIT-RE 500 with HAS rod Setting details Setting operations Drill hole. Put cartridge into dispenser. 32 Throw away first three trigger pulls. Clean hole. Release dispenser. Clean hole. Inject adhesive. Insert anchor. Insert foil pack into holder. Screw on mixer. Wait for curing. Apply tightening torque. Anchoring systems HIT-RE 500 with rebar Recommended load : Frec [kN] Rebar, Hole diameter, D (mm) D D D D D D D D 10 12 12 16 16 20 20 25 25 32 28 37 32 40 40 52 100 Frec 13.3 V(ml) 4 Frec V(ml) Frec V(ml) Frec V(ml) Frec V(ml) Frec V(ml) Frec V(ml) Frec V(ml) Installed Length, lb, inst (mm) 120 16.0 5 19.1 13 140 18.6 6 22.3 16 160 19.1 7 25.5 18 34.0 23 180 19.1 8 27.3 20 38.3 26 200 19.1 9 27.6 22 42.6 29 47.2 45 220 19.1 10 27.6 25 46.8 32 51.9 50 NOT RECOMMENDED Condition: Concrete strength (Cylinder) : fck Steel strength (SD40) : fyk 250 19.1 11 27.6 28 49.0 36 59.0 56 61.8 100 300 19.1 13 27.6 34 49.0 43 70.8 68 74.2 120 76.2 176 350 19.1 15 27.6 39 49.0 50 76.6 79 86.5 140 88.9 205 100.7 202 400 19.1 18 27.6 45 49.0 58 76.6 90 98.8 160 101.6 234 115.1 230 143.9 442 450 19.1 20 27.6 50 49.0 65 76.6 101 111.3 180 114.3 263 129.5 259 161.8 497 500 19.1 22 27.6 56 49.0 72 76.6 113 119.6 200 127.0 293 143.9 288 179.8 552 600 19.1 26 27.6 67 49.0 86 76.6 135 119.6 239 150.1 351 172.6 346 215.8 662 700 19.1 31 27.6 78 49.0 101 76.6 158 119.6 279 150.1 410 196.0 403 251.7 773 800 19.1 35 27.6 90 49.0 115 76.6 180 119.6 319 150.1 468 196.0 461 287.7 883 900 19.1 40 27.6 101 49.0 130 76.6 203 119.6 359 150.1 527 196.0 518 306.3 994 1000 19.1 44 27.6 112 49.0 144 76.6 225 119.6 399 150.1 585 196.0 576 306.3 1104 Length to develop yield, lb (mm) 144 173 230 324 483 590 680 850 = 20 N/mm2 (~200 ksc) = 400 N/mm2 (~4000 ksc) Partial safety factor: Steel, ;s Bond strength, ;b Concrete, ;c Variable actions, ;Q = = = = 1.15 2.16 1.5 1.4 Note: Contact Hilti engineering for exact calculation for your specific application. Setting operations Drill hole. Insert foil pack into holder. Throw away first three trigger pulls. Clean hole. Screw on the mixer. Put cartridge into dispenser. Release dispenser. Inject adhesive. 10 11 12 13 33 Anchoring systems Accessories for HIT-HY 150, HIT-RE 500 Hilti HIT-MD 2000 dispenser Ordering designation Item no. MD 2000 dispenser MD 2500 dispenser Foil pack holder 3:1 P 5000 HY pneumatic dispenser Blow out pump 229154 338853 229170 256083 60579 MD 2000 MD 2500 Blow out pump P 5000 Foil pack holder HAS-E Anchor rod Complete with hexagon nut and washer material grade 5.8 for M8-M24 and grade 8.8 for M27-M39, galvanised to min. 5 microns. Ordering designation Fastenable thickness (mm) Rod length (mm) HAS-E M 8x80/14 HAS-E M 8x80/54 HAS-E M10x90/21 HAS-E M10x90/61 HAS-E M10x90/81 HAS-E M12x110/28 HAS-E M12x110/88 HAS-E M12x110/128 HAS-E M12x110/168 HAS-E M16x125/38 HAS-E M16x125/108 HAS-E M16x125/148 14 54 21 61 81 28 88 128 168 38 108 148 110 150 130 170 190 160 220 260 300 190 260 300 Item no. Ordering designation Fastenable thickness (mm) HAS-E M16x125/198 HAS-E M16x125/348 HAS-E M20x170/48 HAS-E M20x170/68 HAS-E M20x170/108 HAS-E M20x170/158 HAS-E M20x170/208 HAS-E M24x210/54 HAS-E M27x240/60 HAS-E M30x270/70 HAS-E M33x300/80 HAS-E M36x330/90 HAS-E M39x360/100 198 348 48 68 108 158 208 54 60 70 80 90 100 Item no. Ordering designation Fastenable thickness (mm) 333119 333120 333121 333122 333123 333124 333125 333126 333127 333128 333129 HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R HAS-E-R 332219 333099 332220 333100 333101 332221 333102 333103 333104 332222 333106 333107 Rod length (mm) 350 500 240 260 300 350 400 290 340 380 420 460 510 Item no. 333108 333109 332223 333110 333111 333112 333113 332224 333114 333115 333116 333117 333118 HAS-E-R Anchor rod Complete with hexagon nut and washer stainless steel A4-70 / SS316 Ordering designation Fastenable thickness (mm) Rod length (mm) HAS-E-R M 8x80/14 HAS-E-R M 8x80/54 HAS-E-R M 8x80/114 HAS-E-R M10x90/21 HAS-E-R M10x90/61 HAS-E-R M10x90/81 HAS-E-R M10x90/111 HAS-E-R M12x110/28 HAS-E-R M12x110/88 HAS-E-R M12x110/128 HAS-E-R M12x110/168 14 54 114 21 61 81 111 28 88 128 168 110 150 240 130 170 190 220 160 220 260 300 HIS-N Internally threaded sleeve anchor Carbon steel galvanised to min. 5 microns. Ordering designation Sleeve Thread length length (mm) (mm) HIS-N M 8x90 HIS-N M10x110 HIS-N M12x125 HIS-N M16x170 HIS-N M20x205 90 110 125 170 205 34 8-20 10-25 12-30 16-40 20-50 Hole dia.(mm) Use with: 14 18 22 28 32 HVU HVU HVU HVU HVU M10 M12 M16 M20 M24 M16x125/38 M16x125/108 M16x125/148 M16x125/198 M20x170/48 M20x170/108 M24x210/54 M27x240/60 M30x270/70 M33x300/80 M36x330/90 M39x360/100 Rod length (mm) 38 108 148 198 48 108 54 60 70 80 90 100 190 260 300 350 240 260 290 340 380 420 460 510 Item no. 333131 333132 333133 333134 333135 333136 333137 333138 333139 333140 333141 333142 HIS-RN Internally threaded sleeve anchor Stainless steel A4-70 / SS316 Item no. 258015 258016 258017 258018 258019 Ordering designation Sleeve Thread length length (mm) (mm) HIS-RN M 8x90 HIS-RN M10x110 HIS-RN M12x125 HIS-RN M16x170 HIS-RN M20x205 90 110 125 170 205 8-20 10-25 12-30 16-40 20-50 Hole dia.(mm) Use with: 14 18 22 28 32 HVU HVU HVU HVU HVU M10 M12 M16 M20 M24 Item no. 258024 258025 258026 258027 258028 Anchoring systems HVU Adhesive anchor Adhesive capsule Concrete Small edge distance / spacing Shock Fatigue Seismic Corrosion resistance High corrosion resistance Fire Hilti Anchor resistance programme Base material Concrete Hard natural stone Use Heavy-duty fastenings with small spacing and edge distance System Consisting of adhesive in a foil capsule and an anchor rod or internally threaded sleeve Setting operations Features A strong foil capsule Adapts flexibly to fit in irregular holes Capsules do not drop out of overhead holes for HAS-E rod Ordering designation Hole depth. (mm) Hole dia. (mm) HVU M 8x80 HVU M10x90 HVU M12x110 HVU M16x125 HVU M20x170 HVU M24x210 HVU M27x240 HVU M30x270 HVU M33x300 HVU M36x330 HVU M39x360 85 95 115 130 175 215 250 280 310 340 370 10 12 14 18 24 28 30 35 37 40 42 Item no. 256691 256692 256693 256694 256695 256696 256697 256698 256699 256700 256701 HAS-E Setting tool for HIS-N Hexagon insert TE adapter TE Adaptor / Connection end for hexagon inserts Ordering designation For insert size For TE adaptor Item no. TE-C-1/2” TE-FY-3/4” 1/2” 3/4” TE-C TE-Y 32220 32221 Connection TE-C from M8 to M16 Ordering designation For use with TE-C-E M 8 TE-C-E M10 TE-C-E M12 TE-C-E M16 TE-Y-E M16 TE-Y-E M20 TE-Y-E M24 HAS-E M 8 HAS-E M10 HAS-E M12 HAS-E M16 HAS-E M16 HAS-E M20 HAS-E M24 Item no. Connection TE-Y from M16 to M24 369223 369224 369225 369226 369227 369228 369229 35 Anchoring systems Basic loading data (for a single anchor) : HVU capsule with HAS, HAS-E steel grade 5.8 for M8-M24 sizes and steel grade 8.8 for M27-M39 Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting details 36 Anchoring systems HDA Design anchor Self-undercutting anchor Concrete Tension zone Fatigue Shock Seismic Close edge distance/ spacing Performance of a headed stud Fire resistance (F 180) Nuclear power plant approval Hilti Anchor programme Simply reliable Heavy-duty fastenings High loads combined with small edge distance and spacing Dynamic loading, e.g. fatigue, seismic or shock Extreme shear loading Immediate loading capacity after setting Easy removal Material Steel grade 8.8, galvanised to min. 5 microns Fastenings subjected to high shear and dynamic loads Features Self-undercutting system Reliable in all grades of concrete Small edge distance and close spacing Quick and easy setting operation Fastening quality equal to cast-in headed studs HDA-T Anchor for through-fastening Basic loading data (for a single anchor) : HDA-T for M10-M12 : tfix = 10mm for M16 : tfix = 14mm for M20 : tfix = 20mm Max. fastenable thickness, tfix.(mm) Anchor length (mm) Ordering designation 20 30 50 40 60 50 100 150 190 210 275 295 360 410 HDA-T 20-M10x100/20 HDA-T 22-M12x125/30 HDA-T 22-M12x125/50 HDA-T 30-M16x190/40 HDA-T 30-M16x190/60 HDA-T 37-M20x250/50 HDA-T 37-M20x250/100 Item no. 331545 331548 331549 331552 331553 339267 339268 HDA-P Anchor for pre-setting Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Basic loading data (for a single anchor) : HDA-P Recommended load, Lrec [kN]: concrete fck,cube = 25 N/mm2 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Max. fastenable thickness, tfix.(mm) Anchor length (mm) Ordering designation 20 30 50 40 60 50 100 150 190 210 275 295 360 410 HDA-P 20-M10x100/20 HDA-P 22-M12x125/30 HDA-P 22-M12x125/50 HDA-P 30-M16x190/40 HDA-P 30-M16x190/60 HDA-P 37-M20x250/50 HDA-P 37-M20x250/100 Item no. 331544 331546 331547 331550 331551 339265 339266 37 Anchoring systems Required setting tools Anchor Stop drill bit Anchor size Packing contents (pcs) Ordering designation HDA-T 20-M10x100/20 HDA-T 22-M12x125/30 HDA-T 22-M12x125/50 HDA-T 30-M16x190/40 HDA-T 30-M16x190/60 HDA-T 37-M20x250/50 HDA-T 37-M20x250/100 1 1 1 1 1 1 1 TE-C-HDA-B 20x120 TE-C-HDA-B 22x155 TE-C-HDA-B 22x175 TE-Y-HDA-B 30x230 TE-Y-HDA-B 30x250 TE-Y-HDA-B 37x300 TE-Y-HDA-B 37x350 HDA-P 20-M10x100/20 HDA-P 22-M12x125/30 HDA-P 22-M12x125/50 HDA-P 30-M16x190/40 HDA-P 30-M16x190/60 HDA-P 37-M20x250/50 HDA-P 37-M20x250/100 1 1 1 1 1 1 1 TE-C-HDA-B 20x100 TE-C-HDA-B 22x125 TE-C-HDA-B 22x125 TE-Y-HDA-B 30x190 TE-Y-HDA-B 30x190 TE-Y-HDA-B 37x250 TE-Y-HDA-B 37x250 Setting details Setting operations 38 Setting tool Item no. Packing contents (pcs) Ordering designation Item no. 332090 332092 332093 332098 332099 339271 339272 1 1 1 1 1 1 1 TE-C-HDA-ST 20-M10 TE-C-HDA-ST 22-M12 TE-C-HDA-ST 22-M12 TE- Y-HDA-ST 30-M16 TE- Y-HDA-ST 30-M16 TE- Y-HDA-ST 37-M20 TE- Y-HDA-ST 37-M20 331843 331844 331844 331846 331846 339269 339269 332089 332091 332091 332097 332097 339270 339270 1 1 1 1 1 1 1 TE-C-HDA-ST 20-M10 TE-C-HDA-ST 22-M12 TE-C-HDA-ST 22-M12 TE- Y-HDA-ST 30-M16 TE- Y-HDA-ST 30-M16 TE- Y-HDA-ST 37-M20 TE- Y-HDA-ST 37-M20 331843 331844 331844 331846 331846 339269 339269 Anchoring systems HSL-3 Heavy duty anchor Expansion anchor for heavy loads ETA  Concrete Fatigue   Shock Seismic  Tensile zone not for HSL-G-R Fire Small Hilti Anchor edge programme resistance distance / spacing Corrosion resistance Features suitable for the tension zone high loading capacity force-controlled expansion reliable pull-down of part fastened no rotation in hole when tightening bolt Features Integrated plastic section: - to avoid turning in the hole - to telescope and pull down tightly (bridging of gaps) The bolt can be retorqued Fire resistance Material Steel grade 8.8, galvanised to min. 5 microns HSL-3 : heavy-duty anchor Hole dia. do (mm) 12 12 12 15 15 15 18 18 18 24 24 24 28 28 28 32 32 32 Anchor lenght l(mm) Hole depth h1(mm) 83 98 118 95 110 130 111 131 156 138 153 178 163 183 213 185 205 235 80 80 80 90 90 90 105 105 105 125 125 125 155 155 155 180 180 180 Max.thickness fastenable tfix (mm) 5 20 40 5 20 40 5 25 50 10 25 50 10 30 60 10 30 60 Width cross S w(mm) 13 13 13 17 17 17 19 19 19 24 24 24 30 30 30 36 36 36 Ordering designation HSL-3 M 8/ 5 HSL-3 M 8/20 HSL-3 M 8/40 HSL-3 M 10/ 5 HSL-3 M 10/20 HSL-3 M 10/40 HSL-3 M 12/ 5 HSL-3 M 12/25 HSL-3 M 12/50 HSL-3 M 16/10 HSL-3 M 16/25 HSL-3 M 16/50 HSL-3 M 20/10 HSL-3 M 20/30 HSL-3 M 20/60 HSL-3 M 24/10 HSL-3 M 24/30 HSL-3 M 24/60 Item no. 371774 371775 371776 371777 371778 371779 371780 371781 371782 371783 371784 371785 371786 371787 371788 371789 371790 371791 HSL-3-B heavy-duty anchor with torque bolt 18 18 18 24 24 24 28 28 28 32 32 32 117 137 162 144 159 184 169 189 219 191 211 241 105 105 105 125 125 125 155 155 155 180 180 180 5 25 50 10 25 50 10 30 60 10 30 60 24 24 24 30 30 30 36 36 36 41 41 41 HSL-3 -B M 12/ 5 HSL-3 -B M 12/25 HSL-3 -B M 12/50 HSL-3 -B M 16/10 HSL-3 -B M 16/25 HSL-3 -B M 12/50 HSL-3 -B M 20/10 HSL-3 -B M 20/30 HSL-3 -B M 20/60 HSL-3 -B M 24/10 HSL-3 -B M 24/30 HSL-3 -B M 24/60 371807 371808 371809 371810 371811 371812 371813 371814 371815 371816 371817 371818 HSL-3-G heavy-duty anchor - stud version 12 12 12 12 15 15 15 15 18 18 18 18 24 24 24 24 28 28 28 28 87 102 122 182 100 115 135 195 119 139 164 214 148 163 188 238 170 190 220 260 80 80 80 80 90 90 90 90 105 105 105 105 125 125 125 125 155 155 155 155 5 20 40 100 5 20 40 100 5 25 50 100 10 25 50 100 10 30 60 100 13 13 13 13 17 17 17 17 19 19 19 19 24 24 24 24 30 30 30 30 HSL-3 -G M 8/ 5 HSL-3 -G M 8/ 20 HSL-3 -G M 8/ 40 HSL-3 -G M 8/100 HSL-3 -G M 10/ 5 HSL-3 -G M 10/ 20 HSL-3 -G M 10/ 40 HSL-3 -G M 10/100 HSL-3 -G M 12/ 5 HSL-3 -G M 12/ 25 HSL-3 -G M 12/ 50 HSL-3 -G M 12/100 HSL-3 -G M 16/ 10 HSL-3 -G M 16/ 25 HSL-3 -G M 16/ 50 HSL-3 -G M 16/100 HSL-3 -G M 20/ 10 HSL-3 -G M 20/ 30 HSL-3 -G M 20/ 60 HSL-3 -G M 20/100 371792 371793 371794 371829 371795 371796 371797 371830 371798 371799 371800 371831 371801 371802 371803 371832 371804 371805 371806 371833 39 Anchoring systems Basic loading data (for a single anchor) : HSL-3, HSL-B Note : Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting details Setting operations Drill hole. 40 Blow out dust and fragments Install anchor. Apply tightening torque (for HSL-B, no torque wrench is needed). Anchoring systems HSC Safety anchor Self-undercutting anchor Concrete Tension zone Shock Small edge distance / spacing Corrosion Fire resistance Hilti Anchor resistance +hydrocarbon programme curve Features Complete system Keying hold Shallow anchorage depth Low expansion force (thus small edge distance/spacing) Automatic undercutting (without special undercutting tool) Mark on anchor for setting control (easy and safe) Anchorage depth mark on sleeve Suitable for tensile zone Features Anchor hole drilled as usual, without undercutting Automatic undercutting by anchor when anchor sleeve is driven onto stud taper Fire resistance Material Steel grade 8.8, galvanised to min. 5 microns HSC-A : external thread version Basic loading data (for a single anchor) : HSC-A Ordering designation Hole dia. (mm) Anchor length (mm) Item no. HSC-A M 8x40/15 HSC-A M 8x50/15 HSC-A M10x40/20 HSC-A M12x60/20 14 14 16 18 71.5 81.5 79.5 103.5 31139 31141 31140 15507 HSC-I : internal thread version Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation. Basic loading data (for a single anchor) : HSC-I Ordering designation Hole dia. (mm) Anchor length (mm) Item no. HSC-I M 6x40 HSC-I M 8x40 HSC-I M10x50 HSC-I M10x60 HSC-I M12x60 14 16 18 18 20 43 43.5 54.5 64.5 64.5 31142 31143 31144 31145 31146 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation. 41 Anchoring systems Stop bit for exact hole depth Setting tool for automatic undercut Hole dia. (mm) HSC-A HSC-I Ordering designation Item no. External thread Internal thread Ordering designation 14 14 16 18 18 20 M 8x40/15 M 8x50/15 M10x40/20 M12x60/20 - M 6x40 M 8x40 M10x50 M10x60 M12x60 TE-C HSC-B 14x40 TE-C HSC-B 14x50 TE-C HSC-B 16x40 TE-C HSC-B 18x50 TE-C HSC-B 18x60 TE-C HSC-B 20x60 31157 31158 28568 30708 30709 30710 M 8 M10 M12 - M 6 M 8 M10 M12 TE-C TE-C TE-C TE-C Item no. HSC-MW HSC-MW HSC-MW HSC-MW 14 16 18 20 31169 11267 71352 71353 Setting details HSC-A/-AR HSC-I/-IR HSC-A (R) 68 46 46.5 hef [mm] Effective anchorage depth 40 50 40 60 tfix [mm] Max. fixture thickness 15 [Nm] Tightening torque Sw [mm] Width across flats 10 10 13 9 dr [mm] Clearance hole h [mm] Min. base material thickness Drill bit TE-C B- Setting tool TE-C MW- 100 100 68.5 20 60 6/16 - Tinst 68 18 56 50 40 20 smin/smax [mm] Screwing depth M 12x60 16 46.5 M 10x60 14 56 14 M 10x50 18 46 M 8x40 16 [mm] Hole depth M 6x40 [mm] Drill bit diameter h1 Setting Details M 12x60 do M 8x40 M 10x40 HSC-I (R) M 8x50 Anchor size 20 30 17 19 10 12 14 7 100 130 8/22 10 10/28 20 13 9 100 30 17 30 19 12 110 12/30 14 130 130 14x40 14x50 16x40 18x60 14x40 16x40 18x50 18x60 20x60 14 16 18 14 16 18 20 Setting operations for HSC-A 1 mm Check setting of type A anchor Drill hole with stop drill bit. Blow out dust and fragments. Insert type A anchor into hole. Set with setting tool. Secure part being fastened. Setting operations for HSC-I 1 mm Check setting of type I anchor Drill hole with stop drill bit. 42 Blow out dust and fragments. Insert type I anchor into hole. Set with setting tool. Secure part being fastened. Anchoring systems HST Stud anchor Expansion anchor for use in cracked concrete with unique wedge design ETA Concrete Tension zone Shock High Corrosion resistance corrosion resistance Fire Hilti Anchor resistance programme Features High loading capacity Force-controlled expansion Suitable for tension zone Suitable for shock loading Fire prevention assessment Pre-assembled with nut and washer Cold formed High reliability The special expansion-sleeve of the Hilti HST ensures automatic follow-up expansion in cracks and, as a result, reliable anchoring in the tension zone of concrete. HST version : Carbon steel grade 5.8, zinc plated to min. 5 microns Ordering designation Hole dia. (mm) Anchor length (mm) Max. fastenable thickness t fix (mm) HST M 8x75/10 HST M 8x95/30 HST M 8x115/50 HST M 10x90/10 HST M 10x110/30 HST M 10x130/50 HST M 12x115/20 HST M 12x145/50 HST M 12x185/90 HST M 12x215/120 HST M 12x235/140 HST M 12x255/160 HST M 16x140/25 HST M 16x165/50 HST M 16x215/100 HST M 16x255/140 HST M 16x295/180 HST M 20x170/30 HST M 20x200/60 HST M 20x270/130 HST M 24x200/30 HST M 24x230/60 8 8 8 10 10 10 12 12 12 12 12 12 16 16 16 16 16 20 20 20 24 24 75 95 115 90 110 130 115 145 185 215 235 255 140 165 215 255 295 170 200 270 200 230 10 30 50 10 30 50 20 50 90 120 140 160 25 50 100 140 180 30 60 130 30 60 Item no. Intelligent coating Hilti stainless stud anchors (HSA-R, HST-R) are coated to prevent binding between bolt and segment, as well as between bolt and nut. This ensures that the anchor can be tightened and loosened without problems. 371581 Basic loading data (for a single anchor) : HST 371582 371583 Recommended load, L [kN]: concrete f = 25 N/mm2 rec ck.cube 371584 371585 371586 371587 371588 371589 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation. 371590 371591 371592 371593 371594 371595 371596 371597 371598 371599 371600 371601 371602 43 Anchoring systems HST-R version : stainless steel A4-70 Ordering designation Hole dia. do (mm) HST-R M 8x75/10 HST-R M 8x95/30 HST-R M 8x115/50 HST-R M 10x90/10 HST-R M 10x110/30 HST-R M 10x130/50 HST-R M 12x115/20 HST-R M 12x145/50 HST-R M 12x185/90 HST-R M 12x215/120 HST-R M 16x140/25 HST-R M 16x165/50 HST-R M 16x215/100 HST-R M 16x255/140 HST-R M 16x295/180 HST-R M 20x170/30 HST-R M 20x200/60 HST-R M 24x200/30 HST-R M 24x230/60 Anchor length I (mm) Max. fastenable thickness t fix (mm) 75 95 115 90 110 130 115 145 185 215 140 165 215 255 295 170 200 200 230 8 8 8 10 10 10 12 12 12 12 16 16 16 16 16 20 20 24 24 Item no. 376039 376041 376042 376043 376044 376045 376047 376048 376049 376050 376051 376052 376053 376054 376055 376056 376057 376058 376059 10 30 50 10 30 50 20 50 90 120 25 50 100 140 180 30 60 30 60 Basic loading data (for a single anchor) : HST-R Recommended load, Lrec [kN]: concrete fck.cube = 25 N/mm2 Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation. do [mm] Nominal dia. of drill bit I [mm] Anchor length lG [mm] Thread length 12 16 25 45 65 30 50 70 45 75 115 145 165 180 55 80 130 170 180 HST-R 25 45 65 30 50 70 45 75 115 145 40 40 40 40 25 25 25 30 30 30 25 35 35 35 35 35 35 40 45 60 HST-R HST-HCR 40 15 45 60 do [mm] Nominal dia. of drill bit I [mm] Anchor length lG [mm] Thread length M 24x230 M 24x200 65 95 60 60 60 HST-R 45 45 55 55 240 300 Tinst [Nm] Rec. tightening torque 110 SW [mm] Width across nut flats 30 36 125 dr [mm] Clearance hole diameter 22 26 125 h1 [mm] Min. depth of drill hole 140 170 [mm] Effective embed. depth 101 125 40 40 40 40 17 19 24 hef dr [mm] Clearance hole diameter 9 12 14 18 tfix [mm] Max. fastenable thickness h1 [mm] Min. depth of drill hole 65 80 95 115 hmin [mm] Min. concrete thickness hef [mm] Effective embed. depth 46 60 68 82 Drill bit tfix [mm] Max. fastenable thickness hmin [mm] Min. concrete thickness 10 30 50 10 30 50 20 50 90 120 140 160 25 50 100 140 180 100 120 140 160 TE-CX-8 TE-CX-10 TE-CX-12 TE-C-16 or TE-Y-16 30 60 130 30 250 TE-C-S 20 TE-Y 20 TE-C-S 24 TE-Y 24 Setting operations Install anchor. 60 200 HST-HCR is available up to M16. For HST-R the following lengths are not available: M12x235, M12x255, M20x270 44 24 HST 13 Blow out dust and fragments. M 20x270 20 170 200 270 200 230 [mm] Width across nut flats Drill hole with drill bit. M 20x200 Anchor size Setting Details SW Drill bit M 20x170 M 16x295 M 16x255 M 16x215 M 16x165 M 16x140 M 12x255 M 12x235 M 12x215 M 12x185 M 12x145 M 10x30 M 12x115 M 10x90 M 8x95 M 10x110 10 HST HST [Nm] Rec. tightening torque 8 75 95 115 90 110 130 115 145 185 215 235 255 140 165 215 255 295 HST-HCR Tinst M 8x115 Anchor size Setting Details M 8x75 Setting details Apply tightening torque. Anchoring systems HSA Stud anchor Expansion anchor with unique wedge design EOTA Concrete Small edge distance / spacing Fire Hilti Anchor Corrosion resistance programme resistance Features High loading capacity Force-controlled expansion Long thread Head marking for identification after setting Firestop assessment Pre-assembled with nut and washer Cold formed Strong The steel used for the cold-formed HSA is very ductile and hardly breaks. This is a major benefit, especially if a hole is drilled at an angle. Version offered HSA : carbon steel grade 5.8, zinc plated (min. 5 microns) HSA-F : hot dipped galvanized (ISO 1461, 45 microns) HSA-R : A4 stainless steel (DIN 1.4401 / AISI 316) Versatile Versatility in embedment depths. Min. loading values verified by ETA, even with reduced anchorage depths. HSA standard stud anchor Hole dia. do (mm) Anchor length I (mm) Head marking 6 6 6 6 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 16 16 16 20 20 50 65 85 100 57 75 92 115 137 68 90 108 120 80 100 120 150 180 220 240 300 100 120 140 190 240 125 170 A C D E B C E G H C E F G D E G I L O P S E G I L P G K Max. fastenable Standard t fix (mm) 10 30 45 10 27 50 72 20 37 50 5 25 55 85 125 145 205 5 25 75 125 30 thickness Reduced t fix (mm) Ordering designation Item no. Zinc plated (min. 5 microns) Item no. Hot dipped (ISO 1461) Item no. Stainless (A4/AISI 316) 5 20 40 55 5 23 40 63 85 5 25 45 57 5 25 45 75 105 145 165 225 5 25 45 95 145 10 55 HSA M 6x50/ -/5 HSA M 6x65/10/ 20 HSA M 6x85/30/ 40 HSA M 6x100/45/55 HSA M 8x57/ -/5 HSA M 8x75/10/ 23 HSA M 8x92/27/ 40 HSA M 8x115/50/63 HSA M 8x137/72/85 HSA M 10x68/ -/5 HSA M 10x90/20/ 25 HSA M 10x108/37/45 HSA M 10x120/50/57 HSA M 12x80/ -/ 5 HSA M 12x100/5/ 25 HSA M 12x120/25/45 HSA M 12x150/55/75 HSA M 12x180/85/105 HSA M 12x220/125/145 HSA M 12x240/145/165 HSA M 12x300/205/225 HSA M 16x100/ -/5 HSA M 16x120/5/ 25 HSA M 16x140/25/45 HSA M 16x190/75/95 HSA M 16x240/125/145 HSA M 20x125/ -/ 10 HSA M 20x170/30/55 255830 255831 255832 255833 255834 255835 255836 255837 255838 255839 255840 255841 255842 255844 255845 255846 255847 255848 255849 255850 255851 255852 255853 255854 255855 255856 255857 255858 338260 337121 337122 337123 337124 337125 337126 337127 337128 337129 337130 337131 337132 337133 338261 337134 337135 337136 337137 332183 332184 332185 332186 332187 332188 332189 332190 332191 332192 332193 332194 332195 337116 337117 337118 337119 337120 45 Anchoring systems Basic loading data (for a single anchor) Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Recommended load, Lrec [kN] : concrete fck,cube = 25 N/mm2 : HSA Anchor size M6 M8 M10 M12 M16 M20 M6 Standard anchorage depth M8 M10 M12 M16 M20 Reduced anchorage depth Tensile NRec 2.4 4.8 4.8 8.5 16.6 23.8 1.4 4.3 4.8 5.4 9.5 14.3 Shear VRec 2.6 4.6 7.1 10.1 18.9 29.6 2.4 4.6 7.1 10.1 18.9 29.6 M10 M12 M16 M20 Recommended load, Lrec [kN] : concrete fck,cube = 25 N/mm2 : HSA-F Anchor size M6 M8 M10 M12 M16 M20 M6 Standard anchorage depth M8 Reduced anchorage depth Tensile NRec 2.4 4.8 4.8 8.5 16.6 23.8 1.4 4.3 4.8 5.4 9.5 14.3 Shear VRec 2.6 4.6 7.1 10.1 18.9 29.6 2.4 4.6 7.1 10.1 18.9 29.6 M10 M12 M16 M20 Recommended load, Lrec [kN] : concrete fck,cube = 25 N/mm2 : HSA-R Anchor size M6 M8 M10 M12 M16 M20 M6 Standard anchorage depth M8 Reduced anchorage depth Tensile NRec 2.4 4.8 4.1 8.5 15.4 17.5 1.4 3.0 4.1 6.1 9.1 13.2 Shear VRec 2.8 5.2 8.1 11.9 22.4 35.0 2.8 5.2 8.1 11.9 22.4 35.0 Setting details Setting operations Drill hole with drill bit. 46 Blow out dust and fragments. Install anchor. Apply tightening torque. Anchoring systems HLC Sleeve anchor For light to medium duty general fastening Concrete Fire resistance Features For concrete and solid masonry Force-controlled expansion No rotation in hole when tightening bolt Reliable pull-down of part fastened Material Steel grade 6.8, galvanised to min. 5 microns Features Bridging of gaps Wide range of applications in concrete, solid brick etc. Removable HLC Sleeve anchor : stud version Thread dia. Max. thickness do (mm) fastenable, t fix (mm) M 5 M 5 M 5 M 6 M 6 M 6 M 6 M 8 M 8 M 8 M 8 M 8 M10 M10 M10 M12 M12 M12 M16 M16 M16 5 20 40 12 27 42 57 8 18 28 48 68 17 37 62 12 52 92 25 60 95 Setting details Hole dia., do (mm) Anchor length l (mm) Hole depth h1 (mm) Ordering designation 6.5 6.5 6.5 8 8 8 8 10 10 10 10 10 12 12 12 16 16 16 20 20 20 30 45 65 46 61 76 91 48 58 68 88 108 65 85 110 72 112 152 95 130 165 30 30 30 40 40 40 40 47 47 47 47 47 56 56 56 72 72 72 85 85 85 HLC 6.5x25/5 HLC 6.5x40/20 HLC 6.5x60/40 HLC 8 x40/12 HLC 8 x55/27 HLC 8 x70/42 HLC 8 x85/57 HLC 10 x40/8 HLC 10 x50/18 HLC 10 x60/28 HLC 10 x80/48 HLC 10 x100/68 HLC 12 x55/17 HLC 12 x75/37 HLC 12 x100/62 HLC 16 x60/12 HLC 16 x100/52 HLC 16 x140/92 HLC 20 x80/25 HLC 20 x115/60 HLC 20 x150/95 Item no. 230768 230769 230770 230771 230772 230773 230774 230775 230776 230777 230778 230779 230780 230781 230782 230783 230784 230785 230786 230787 230788 Basic loading data (for a single anchor) : HLC Recommended load, Lrec [kN] Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting operations Drill hole Blow out dust with drill bit. and fragments. Install the anchor. Apply torque. 47 Anchoring systems HKD-S Flush anchor Internally threaded anchor with flared end for flush setting Concrete Corrosion Fire Hilti Anchor resistance resistance programme Features Internal thread and small depth of embedment Anchor flush with surface Movement-controlled expansion Unsinkable The flared end on the Hilti HKD-S, ensures accurate setting flush with the surface independent of the hole depth. Available in galvanized steel, sherardised and stainless steel. These anchors are ideal for setting in the undersides of cavity ceilings. Material Galvanised min. 8 µm. Stainless Steel A4, AISI 316 HKD-S version : galvanised steel Thread. size Anchor length hnom (mm) Hole dia. do (mm) Hole depth, h1 (mm) Ordering designation Item no. M 6 M 6 M 8 M 8 M10 M10 M12 M16 M20 1/4” 5/16” 3/8” 3/8” 1/2” 5/8” 3/4” 25 30 30 40 30 40 50 65 80 25 30 30 40 50 65 80 8 8 10 10 12 12 15 20 25 8 10 12 12 16 20 25 27 32 32 42 33 43 53 69 85 27 32 33 43 53 69 85 HKD-S M 6x25 HKD-S M 6x30 HKD-S M 8x30 HKD-S M 8x40 HKD-S M 10x30 HKD-S M 10x40 HKD-S M 12x50 HKD-S M 16x65 HKD-S M 20x80 HKD-S 1/4” x25 HKD-S 5/16”x30 HKD-S 3/8” x30 HKD-S 3/8” x40 HKD-S 1/2” x50 HKD-S 5/8” x65 HKD-S 3/4” x80 242861 242862 242866 242867 243737 242869 242871 242873 242875 242864 242868 230929 246713 242872 242874 242865 HKD-SR version : stainless steel Thread. size Anchor length h nom (mm) Hole dia. do (mm) Hole depth, h1 (mm) Ordering designation M 6 M 8 M10 M12 M16 M20 25 30 40 50 65 80 8 10 12 15 20 25 27 32 42 53 69 85 HKD-SR HKD-SR HKD-SR HKD-SR HKD-SR HKD-SR Item no. M 6x25 M 8x30 M 10x40 M 12x50 M 16x65 M 20x80 247951 247952 247953 247954 247955 247956 HKD Hand setting tool Ordering designation HSD-G M 6 HSD-G M 6 HSD-G M 8 HSD-G M 8 HSD-G M10 HSD-G M10 HSD-G M12 HSD-G M16 HSD-G M20 48 For use with 1/4”x25 1/4”x30 5/16”x30 5/16”x40 3/8”x30 3/8”x40 1/2”x50 5/8”x65 3/4”x80 HKD M 6 1/4”x25 HKD M 6 1/4”x30 HKD M 8 5/16”x30 HKD M 8 5/16”x40 HKD M10 3/8”x30 HKD M10 3/8”x40 HKD M12 1/2”x50 HKD M16 5/8”x65 HKD M20 3/4”x80 Item no. 243738 243739 243740 243741 230935 243742 243743 243744 243745 Anchoring systems [mm] Drill bit diameter h1 [mm] Hole depth hef [mm] Min. anchorage depth l [mm] Anchor length smin/smax [mm] Screwing depth 12 15 20 25 33 43 54 70 85 25 30 30 40 30 40 50 65 80 8/11 14/22 18/28 23/34 Tinst [Nm] Tightening torque 4 4 8 8 15 15 35 60 120 dr [mm] Clearance hole 7 7 9 9 12 12 14 18 22 h [mm] Min. base material thickness 100 100 100 100 100 100 100 130 160 TE-CX15/17 TE-TX15/22 TE-C20/22S TE-Y20/32S TE-C25/27S TE-Y25/32S Drill bit 8/11 10/13 10/13 TE-CX-8/17 TE-CX-10/17 12/12 12/16 M 20x80 3/4"x80 12 43 M 16x65 5/8"x65 10 M 12x50 1/2"x50 10 33 M 10x40 3/8"x40 8 32 M 10x30 3/8"x30 8 27 M 6x30 M 8x40 do M 6x25 1/4"x25 Anchor size Setting Details M 8x30 5/16"x30 Setting details TE-CX-12/17 TE-TX-12/22 HKD-E/-S/-R Basic loading data (for a single anchor) : HKD-E/ -S/ -R Recommended load, Lrec [kN] : concrete fck,cube = 25 N/mm2 Anchor size M6X30 M8X30 M8X40 M10X30 M10X40 M12X50 M16X65 M20X80 Tensile NRec 3.3 3.3 3.6 3.3 5.1 7.1 12.6 17.2 Shear VRec 2.1 3.9 3.9 4.2 4.6 8.1 12.5 19.9 Bolt: 5.6, EN ISO 898-1 Min. length of thread engagement = bolt thread size + 2mm Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting operations Drill hole. Blow out dust and frangments. Install the anchor. Push in until marking is visible. 49 Anchoring systems HHD-S Cavity anchor Cavity anchor for installations on gypsum wallboard or hollow brick Features Base material: particle / chip board, drywall panel, hollow blocks Max. holding power in thin-walled base material owing to optimised keying hold Easy, rapid and controlled setting Prefitted screw in all sizes Force-controlled expansion HHD Cavity anchor Ordering designation Hole dia. do (mm) Anchor length (mm) HHD-S M4/4x20 HHD-S M4/6x32 HHD-S M4/12x38 HHD-S M4/19x45 HHD-S M5/8x38 HHD-S M5/12x52 HHD-S M5/25x65 HHD-S M6/9x38 HHD-S M6/12x52 HHD-S M6/24x65 HHD-S M8/12x54 HHD-S M8/24x66 8 8 8 8 12 12 10 12 12 12 12 12 20 32 38 45 38 52 65 38 52 65 54 66 Item no. 332060 332061 332062 332063 332065 332066 332067 332069 332070 332071 332073 332074 HHD Setting tool Ordering designation For anchor sign HHD-SZ 2 M4-M8 Item no. 332076 Setting operations Basic loading data (for a single anchor) : HHD-S different kinds of base material through-fastening Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Recommended load, Lrec [kN] : Anchor size M4/12x38 M4/19x45 M5/12x52 M5/25x65 M6/12x52 M6/24x65 M8/12x54 M8/24x66 Base material NRec VRec NRec VRec NRec VRec NRec VRec NRec VRec NRec VRec NRec VRec Particle / chip board 10 [mm] 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 Drywall panel 10 [mm] 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 Drywall panel 12.5 [mm] 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 Drywall panel 2x12.5 [mm] 10 [mm] 0.2 0.5 0.3 0.6 Gypsum fibreboard 12.5 [mm] 0.3 0.6 0.5 1.0 Gypsum fibreboard 2x12.5 [mm] Gypsum fibreboard Hollow brick NRec VRec 0.4 1.0 20 [mm] 0.3 0.9 0.4 1.0 0.25 0.8 0.4 0.9 0.3 1.0 0.9 1.1 0.6 1.2 0.8 1.8 0.9 1.7 0.1 0.3 M 5x12 M 5x25 M 6x9 M 6x12 M 6x24 M 6x40 M8x12 M 8x24 M 8x40 8 8 8 10 10 10 12 12 12 12 12 12 12 20 32 38 45 38 52 65 38 52 65 80 54 66 83 ls [mm] Min. screw length 25 39 45 52 45 58 71 45 58 71 88 60 72 90 h [mm] Anchor neck length 4 6 12.5 19 8 12.5 25 9 12.5 25 40 12.5 25 40 hmin/max [mm] Min./Max.panel thickness 3/4 6/7 10/13 18/20 6/8 11/13 18/28 7/9 11/13 23/25 38/40 tfix [Nm] max.fastenable thickness 15 25 25 25 25 30 30 20 30 30 30 30 30 35 d [mm] Screw diameter M4 M4 M4 M4 M5 M5 M5 M6 M6 M6 M6 M8 M8 M8 50 TE-CX-8/22 M 5x8 8 [mm] Anchor length M 4x6 [mm] Drill bit diameter l M 4x4 do Drill bit M 4x19 Anchor size Setting Details M 4x12 Setting details TE-CX-10/22 11/13 23/25 TE-CX-12/22 38/40 Anchoring systems HPS-1 Impact anchor Hammer-in anchor for through fastening Features Base material: concrete, soild or hollow brick and aerated concrete Ready-to-use anchor for through-fastening Bridging of gaps due to collapsible section Impact expansion by hammer or screwdriver Wide product programme Removable and adjustable with a screwdriver Material PA 6 polyamide, contains no heavy metals Features Pre-assembled screw and body Can be set using a screwgun, screwdriver or hammer Only one anchor type required for both solid and hollow materials Drive screw Steel galvanised to 5 microns HPS-1 : galvanised version Basic loading data (for a single anchor) : HPS-1 different kinds of base material aerated concrete Recommended load, Lrec [kN] : Ordering designation Hole dia. do (mm) HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 HPS-1 4 5 5 5 5 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 4/0x20 5/0x20 5/5x25 5/10x30 5/15x35 6/0x25 6/5x30 6/10x35 6/15x40 6/25x50 6/30x55 6/40x65 8/0x25 8/10x40 8/20x50 8/30x60 8/40x70 8/60x90 8/80x110 8/100x130 Anchor length (mm) 21.5 22 27 32 37 27 32 37 42 52 57 67 42.5 42.5 52.5 62.5 72.5 92.5 112.5 132.5 Anchor size Item no. 260369 260395 260347 230515 260348 238159 260349 230516 260350 260351 230517 260352 238160 260353 230518 260354 230519 260355 260356 260367 Base material HPS-1 4/0 HPS-1 5/0 HPS-1 5/55/15 HPS-1 6/06/25 HPS-1 6/306/40 HPS-1 8/0 HPS-1 8/108/40 HPS-1 8/608/100 NRec VRec NRec VRec 0.05 0.1 0.15 0.25 0.25 0.3 0.4 0.4 0.15 0.05 0.3 0.1 0.35 0.15 0.55 0.25 0.35 0.25 0.5 0.3 0.9 0.4 0.5 0.4 0.15 0.3 0.35 0.55 0.35 0.5 0.9 0.5 Perforated brick, 3 hole cammon NRec VRec 0.05 0.1 0.15 0.2 0.2 0.25 0.3 0.3 0.15 0.3 0.35 0.55 0.35 0.5 0.9 0.55 Themalite block, 7 N, lightweight NRec VRec - - 0.08 0.15 0.15 0.2 0.25 0.25 - - 0.15 0.25 0.15 0.4 0.4 0.25 Themalite block, 1/2 N, lightweight NRec VRec - - 0.05 0.08 0.08 - 0.12 0.12 - - 0.1 0.15 0.1 - 0.25 NRec VRec - - 0.08 0.1 0.1 - 0.15 0.15 - - 0.1 0.12 0.1 - 0.3 0.2 NRec VRec 0.05 0.1 0.15 0.2 0.2 0.25 0.35 0.35 0.15 0.25 0.3 0.4 0.25 0.5 0.9 0.55 Concrete, fcc= 20-45 N/mm2 Engineering brick, 12 hole, class B Aerated concrete, PB 4, PB 6 Extruded brick, Boral 10 1) 0.15 1) Hole drilled with TE-CX drill bit, without hammering action. If at temperatures above 40 C loads are sustained, recommended loads should be reduced. Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting operations Setting details 51 Anchoring systems HUD-1 Universal anchor Plastic anchor for problematic base materials (gas concrete, fragile hollow bricks, etc) Features Base material: concrete, solid brick, hollow brick, gas (aerated) concrete, gypsum panel High holding power Suitable for through-fastening with screw Resistance to turning in hole and premature expansion Low screw driving torque permits rapid setting Resistant to temperature, impact and chemicals Optimal screw guidance Material PA 6 polyamide, contains no heavy metals HUD-1 Universal anchor HUD-L Extra long Ordering designation Hole dia. do (mm) Anchor length (mm) HUD-1 5x25 HUD-1 6x30 HUD-1 8x40 HUD-1 10x50 HUD-1 12x60 HUD-1 14x70 5 6 8 10 12 14 25 30 40 50 60 70 Item no. 331615 331616 331617 331618 331619 331620 Basic loading data (for a single anchor) : HUD-1 Ordering designation Hole dia. do (mm) Anchor length (mm) HUD-L 6x50 HUD-L 8x60 HUD-L 10x70 6 8 10 50 60 70 Item no. 315938 315939 315940 Setting operations Recommended load, Lrec [kN] : Anchor size HUD-1 5x25 Base material Woodscrew Concrete, fcc = 30N/mm 2 NRec VRec Aerated concrete, PB 2 1) NRec VRec Aerated concrete, PB 4 NRec VRec Solid brick, Mz 20-1.8-1 NF NRec VRec Sand-lime solid block, KS 12-1.6-2 /DF HUD-1 6x30 HUD-1 8x40 HUD-1 10x50 HUD-1 12x60 HUD-1 14x70 Particle board screw Woodscrew Particle board screw Woodscrew Particle board screw 0.3 0.1 0.55 0.35 0.85 0.5 1.4 - 2.0 3.0 0.4 - 0.9 - 1.25 - 2.2 - 3.0 5.6 0.3 Woodscrew Particle board screw Woodscrew Woodscrew 0.06 0.04 0.1 0.06 0.15 0.1 0.2 - 0.25 0.04 - 0.05 - 0.08 - - - - - 0.1 0.06 0.15 0.1 0.3 0.2 0.4 - 0.5 0.6 0.13 - 0.18 - 0.3 - - - - - 0.17 0.06 0.35 0.15 0.6 0.35 0.8 - 1.0 1.05) 0.24 - 0.3 - 0.44 - - - - - NRec VRec 0.25 0.15 0.5 0.3 0.85 0.4 1.0 - 1.5 1.55) 0.25 - 0.56 - 0.74 - 1.32 - - - Hollow brick, HlzB 12-1.0x5DF 1) NRec VRec 0.08 0.05 0.1 0.08 0.25 - 0.35 - - - - 0.28 - 0.32 - 0.2 - 0.12 0.23 Hollow brick, HlzB 12-1.0x5DF 1) 15 mm plastered DIN 18550 NRec VRec 0.08 0.05 0.15 0.1 0.25 0.15 - 0.35 0.4 0.23 - 0.35 - - - 0.03 - Gypsum panel 2) , 12.5 mm NRec VRec 0.04 0.06 0.05 0.08 0.06 0.1 - 0.09 - 0.14 - - - Gypsum panel 2) , 2x12.5 mm NRec VRec 0.06 0.06 0.8 0.08 0.1 0.1 0.09 - 0.14 - - - Fibre reinforced gupsum panel 12.5 mm NRec VRec 0.15 - 0.20 - 0.30 - 0.24 - 0.32 - 0.48 - - - - - Fibre reinforced gupsum panel 2x12.5 mm NRec VRec 0.15 - 0.40 - 0.60 - 0.70 - - - 0.24 - 0.64 - 0.96 - 1.12 - - - - - - - - - - 0.153) - - - 0.153) 0.23) 0.34) - - - - - - - - - Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. Setting details Anchor size Setting Details HUD-1 5x25 HUD-1 6x30 HUD-1 8x40 HUD-1 10x50 HUD-1 12x60 Anchor size HUD-1 14x70 Setting Details HUD-L 6x50 HUD-L 8x60 HUD-L 10x70 do [mm] Drill bit diameter 5 6 8 10 12 14 do [mm] Drill bit diameter 6 8 10 h1 [mm] Min. hole depth 35 40 55 65 80 90 h1 [mm] Min. hole depth 70 80 90 ld [mm] Anchor length 25 30 40 50 60 70 ld [mm] Anchor length 50 60 70 tfix [mm] max. fixture thickness Recommended woodscrew type d [mm] Woodscrew diameter SK/RK 3.5-4 SK/RK 3.5-4 Screw length Drill bit Recommended woodscrew diameter depends on screw lengths SK/RK 3.5-4 SK/RK 3.5-4 SK/RK 3.5-4 SK/RK tfix [mm] max. fixture thickness 3.5-4 d [mm] Woodscrew diameter ld [mm] req. length of screw engagement in base material ld + tfix + 5 mm TE-CX-5/12 TE-CX-6/12 TE-CX-8/17 TE-CX-10/17 TE-CX-12/17 depends on screw length 4.5-5 5-6 7-8 55 65 75 TE-CX-6/17 TE-CX-8/17 TE-CX-10/22 TE-CX-14/17 Drill bit 52 common woodscrews and particle board screws Anchoring systems HLD Light-duty anchor For all light duty fastenings, in drywall and hollow materials Features Base material: virtually all existing building materials, especially panels and similar Universal/versatile in thin-walled and solid base materials, even if they are of low strength Bridges a large range of wall/panel thickness Safe against rotation in hole Excellent screw guidance Simple setting Setting check through noticeable increase in resistance when the screw has been driven home Material Polyamide PA 6, containing no heavy metals Setting operations HLD Hole dia. do (mm) Base material thickness h (mm) Screw shank dia. d (mm) Ordering designation 9-10 9-10 9-10 4-12 15-19 24-28 4-4.5 4-4.5 4-4.5 HLD 2 HLD 3 HLD 4 Item no. 335506 335507 335508 Basic loading data (for a single anchor) : HLD Recommended load, Lrec [kN] : Base Material Anchor working principle HLD 3 HLD 4 Concrete: fcc = 15 N/mm 2 C 0.25 0.4 0.5 Gypsum panel B 0.08 0.08 0.08 A 0.1 - - Fibre reinforced gypsum panel 12.5mm Fibre reinforced gypsum panel 2x12.5mm Note: Edge distance, spacing and other influences are not considered. Contact Hilti engineering for exact calculation of your specific application. size of anchor HLD 2 A - 0.2 - Asbestos cement A 0.12 0.12 0.12 Hollow brick, fired 0.15 0.15 A/B 0.15 Sand-lime solid block KS 12-1.6-2DF C 0.25 0.4 0.5 Woodwool panel A - 0.05 0.05 AT temperatures above 40 C, the recommended load should be reduced for sustained tensile loading Setting details Anchor size Setting Details do1) [mm] Drill bit diameter h1 [mm] hole depth ls [mm] screw length d [mm] Screw diameter h [mm] Wall/panel thickness Drill bit Anchor working principle HLD2 HLD3 HLD4 HLD2 HLD3 HLD4 HLD2 - - - - - 50 56 33+ tfix 40+ tfix 49+ tfix 33+ tfix 40+ tfix 49+ tfix 40+ tfix 46+ tfix 4-5 4-12 15-19 24-28 66 56+ tfix 5-6 12-16 19-23 28-32 from35 from42 from50 TE-CX-10/17, TE-CX-9/22 1) A HLD4 9 9-10 - HLD3 B TE-CX-9/22 C 1) Use a 9mm twist drill for gypsum panel and woodwool panels but a 10 mm drill bit for concrete. 53 54 Flammable pipes Building joints CP 643 CP 644 CP 601S CP 606 CP 672/ CP 604 CP 611A Flammable pipes<50 mm Curtain walling Quality approved product. On-site advice and surveys. Comprehensive solutions for all types of penetrations. All penetrations and openings in all kinds of buildings through which flames, heat or fumes from a fire could spread, can be sealed with Hilti firestop systems to minimise fire damage. CP 601S Non-flammable pipes Feel safe and confident in all areas with Hilti firestop systems CP 656 Single cables/cable bundles Permanent Cable trays CP 611A CP 680 CP 636 Simple retrofitting of cables Cable trays CP 620 CP 651 FS 657 CP 670 Construction chemicals and Firestop systems Construction chemicals and Firestop systems CP 601S Elastic firestop sealant Applications Construction joints/sealing penetration for metal pipes Sealing expansion joints and stretched connection joints where stringent fire prevention requirements must be met Sealing metal pipe and HVAC penetrations Product description Elastic firestop sealant (neutral silicone) classified as material class B1 (low flammability) Technical data Density : Cartridge contents : Application temperature : Skin-forming time : Curing rate : Volume shrinkage : Max. deformation : Temperature resistance : Material class as per DIN 4102, T.1 : Shelf-life after production : approx. 1.4 g/cm3 310 ml +5°C to +40°C approx. 15 min. approx. 2 mm in 3 days 0-5% 25% -30°C to +150°C B1 12 months (at 20°C in a dry place) CP 606 Fire resistant joint filler Applications Sealing rigid or low movement joints where fire prevention requirements must be met. Sealing metal pipe and HVAC penetrations Product description Firestop sealant (acrylic-dispersion) Technical data Density : Cartridge contents : Application temperature : Skin-forming time : Curing rate : Volume shrinkage : Max. deformation : Temperature resistance : Shelf-life after production : approx. 1.5 g/cm3 310 ml +5°C to +40°C approx. 15 min. approx. 2 mm in 3 days approx. 20% 10% -40°C to +80°C 12 months (at 20°C in a dry place) Product features Halogen and solvent free Weather and UV-resistant System advantages/customer benefits Simple use and application Good adhesion without use of a primer Smoke, gas and water tight Excellent movement capability Ordering Packaging designation contents CP 601S 310ml Firestop sealant, white 20 CP 601S 310ml Firestop sealant, grey 20 CP 601S 310ml Firestop sealant, anthracite 20 DIN 4102 Applications Sealing small to medium-sized penetrations Permanent fire seals for single and bunched cables. Sealing around flammable pipes up to max. 50 mm diameter Resealing of penetrations previously sealed with CP 636 firestop mortar, after installing additional cables. Product description Water-based intumescent acrylic, mastic Technical data Density : Colour : Cartridge contents : Application temperature : Skin-forming time : Curing rate : Intumescent phase : Movement acceptance : Material class as per DIN 4102, T.1 : Temperature resistance : Shelf-life after production : approx. 1.3 g/cm3 Grey 310 ml +5°C to +40°C approx. 10 min. approx. 3 mm in 3 days from +140°C to +180°C 10% B1 (Fire reaction) -40°C to +140°C 12 months (at 20°C in a dry place) UL 2079, UL1479 (ASTM : E 814) FM Product features Silicone free Halogen and solvent free UV resistant System advantages/customer benefits Paintable Simple use and application Smoke, gas and water tight Easy clean up with water Ordering designation CP 606 310ml Firestop sealant, white CP 606 310ml Firestop sealant, grey DIN 4102 CP 611A Intumescent firestop mastic BS 476:Part 20, 1987. Insulation/integrity Item no. 310633 310635 310634 BS 476:Part 20, 1987. Insulation/integrity Packaging contents Item no. 20 20 310638 310639 UL 2079, UL1479 (ASTM : E 814) FM Product features Expands in fire, protection pipe and cable penetrations Smoke, gas and water tight Halogen and solvent free Odourless System advantages/customer benefits Easy to work with thanks to thick consistency Wide range of applications Paintable Quick sealing of remaining gaps Particularly suitable for laying new cables Can be used for outdoor applications Ordering designation CP 611A 310ml Intumescent firestop mastic BS 476:Part 20, 1987. Insulation/integrity Packaging contents Item no. 20 220351 UL 2079, UL1479 (ASTM : E 814) FM 55 Construction chemicals and Firestop systems FS ONE High performance intumescent Applications Steel, copper and EMT pipes Insulated steel and copper pipes Jacketed cables and cable bundles Small plastic pipes up to 50 mm diameter For use on concrete, masonry, blockwork, drywall and wood Tested in combination with FS FireBlock as a gap filler Technical data Density : Application temperature : Curing time : Expansion rate : Colour : Temperature resistance : PH-Value : Shore A Hardness : Joint movement capability : Shelf-life : (at 20°C and stored in a dry place) approx. 1.5 g/cm3 +5°C to +40°C approx. 2 mm. in 3 days 1 : 3-5 red -40°C to +100°C approx. 7.5 approx. 35 max. 10% 9 months CP 620 Expanding fire seal Applications Sealing small to medium-sized openings for a fire integrity of up to 2 hours. Permanent fire seal for cables and cable trays max 600x400 mm opening. Permanent fire seal for non-combustible pipes. Permanent fire seal for combustible pipes in conjunction with CP 649. Permanent fire seal where cables, steel, copper, cast iron or plasticpipes all pass through the same opening in one seal. Technical data Chemical basis : CP 636 Firestop mortar Applications Permanent fire seal for cables and cable trays in medium to very large opening 56 1 Ordering designation 3:1 (mortar to water) ideal between 5° and 45°C grey after 2-4 hours (walls) after 2-12 hours (floors) 0.82 g/cm3 2.9 N/mm2 A1 (fire rection) 12 months (at 30°C in a dry place) 2 Packaging contents FS ONE, tube FS ONE, foil Accessory Manual dispenser CB 200-P1 Manual dispenser CS 270-P1CS 300 ml 600 ml Item no. 259579 311387 310 ml 600 ml 055205 024669 UL 2079, UL1479 (ASTM : E 814) FM System advantages/customer benefits Simple use and application Good adhesion without use of a primer Smoke, gas and water tight Excellent movement capability CP 620 Brand schutz besch ichtun sodfm,e g v iJdjfiwh riuh. N oWE 4i5kirdw u9+§12 iloi4jtf- x-.vbvb oeoo vh, ireiv 1 Two-component polyurethanefoam Red Up to 2.2 I 300 ml +10°C to +30°C -30°C to +100°C Colour : Fire seal yield : Cartridge contents : Application temperature : Temperature resistance : Minimum temperature : -Substrate +0°C -Cartridge +10°C Storage/transport temperature : +5°C to +25°C Curing : -Non-tacky after Approx. 35 s -Ready to cut after Approx. 1 min Construction materials class as per : DIN 4102 B1 Shelf life : (at 20°C and stored in a dry place) 9 months Thermal insulation : -Warm pipes 0.052 W/mk at 90°C -Cold pipes 0.048 W/mk at 25°C Comparable to Foamglas, Armaflex and mineral wool Acoustic insulation (air-borne sound) : 59 db, as per DIN 4109 Structure-borne sound insulation : Pipe/wall 30-50% Technical data Mix ratio : Application temperature : Colour : Form removal (depending on consistency) : Density of hardened mortar : Compressive strength (after 28 days at 23°c) : Material class as per DIN 4102, T.1 : Shelf-life after production : Product description FS-ONE is an acrylic based intumescent firestop sealant. Product features Contains no halogen or solvents High fire rating properties Water based, easy to clean Impermeable to smoke, gas and water 2 Ausführungsschild Ordering designation Packaging contents CP 620 Expanding fire seal (300 ml) DSC Dispenser (carton) DIN 4102 BS 476:Part 20, 1987. Insulation/integrity 12 1 UL 2079, UL1479 (ASTM : E 814) Item no. 337725 338720 FM Product features No additional components required (except when cable runs/trays are directly on an opening surface) Adheres very well to common substrates (steel, concrete or masonry) Impervious to smoke or gas and water resistant Contains no asbestos, phenol or halogen constituents Product description Fire-resistant, cement-based mortar with thermal insulation properties from admixed perlite Ordering designation Packaging contents CP 636 Firestop mortar, 20 kg bag BS 476:Part 20, 1987. Insulation/integrity 1 UL 2079, UL1479 (ASTM : E 814) Item no. 334897 FM 1 2 1 2 Construction chemicals and Firestop systems CP 637 High strength compound System advantages/customer benefits Quick setting Load bearing to right foot traffic Adhesive well to common substrates Applications Sealing for cables and cable trays opening Sealing for multiple pipe penetration technical data Technical data Mix ratio : (recommanded) Application temperature : Colour : Expansion on setting (approx) : Compressive strength : Pourable : after 24 hrs. after drying Plastic : after 24 hrs. after drying Stiff : after 24 hrs. after drying Curing time : Formwork removable : 3:1 (mortar to water) trowelable 40°F / 5°C to 110°F / 43°C Light red 0.08% 24 hrs. 2.5 Nmm2 5.0 Nmm2 4.2 Nmm2 4.2 Nmm2 6.0 Nmm2 12.3 Nmm2 45 minutes 2 hour Ordering designation Packaging contents CP 637 Firestop compound, 13.5 kg bag BS 476:Part 20, 1987. Insulation/integrity 1 UL 2079, UL1479 (ASTM : E 814) Item no. 340645 FM CP 670 Fire safety board system Applications Suitable for drywall, masonry and concrete applications. Single cable, cable bundle, cable tray, air ducts and dampers, pipes Large diameter range for single cables and cable bundles. Combustible and non-combustible plastic pipes. Large penetrations possible up to 5 metres high by any length. Large drywall systems. Single layer, double layer and double layer framed systems available and tested. Technical data Colour : white Thickness of coating : 0.7 mm Dimensions : 1200x600x50 mm Board density : 160 kg/m3 Acoustic insulation : acc. to ISO 140-10 / ISO 717-1 Single layer system (Block wall) : 30 dB Single layer system (Dry wall) : 39 dB Double layer system (Block wall) : 42 dB 30 years age testing : acc.to the DAfStb guideline for protection and repair of concrete components, part 4, paragraph 2.4.5.6.1. (following fire test as per DIN 4102-9) Product features Board fully coated: no fraying of edges and no mineral fibre exposure. No body contact with mineral fibre, a common cause of skin allergy. Odourless and solvent-free. Virtually no cracking or delamination during cutting. Ordering designation Packaging contents CP 670 Fire safety board system CP 670 Fire safety coating (6.5 kg) 20 1 Ordering designation Packaging contents Item no. 376024 376023 CP 643, CP644 Firestop jacket Product description A ready-to-use firestop jacket, made of a galvanized steel housing. intumescent inserts and the required number of fastening hooks. (CP 643) Galvanised sheet containing sections of intumescent material (which foams and expands in a fire) (CP 644) Applications Sealing flammable pipes from 32 to 250 mm in diameter with pipe wall thicknesses from 1.8 to 22.8 mm. Suitable for : - B1/B2 pipes - PVC, PP, PE, ABS - Pipe with acoustic insulation. Product features No minimum distance required between several jackets Ready-to-use jacket; no preparatory work required, therefore fast installation time Technical data CP 643 firestop jacket Pipe outside dia. (mm) Jacket outside dia.(mm) Jacket length (mm) No. of hooks and fasteners CP 643-50/1.5” CP 643-63/2” CP 643-90/3” CP 643-110/4” CP 643-125/5” CP 643-160/6” 36-51 52-64 65-91 92-115 116-125 126-170 69+1 85+1 121+1 151+1 166.1 235.5 22.4 32.4 42.4 47.4 47.8 48.2 2 2 3 3 4 4 CP 644-180/7” CP 644-200/8” CP 644-225/9” CP 644-250/10” 180 200 225 250 229 255 283 315 150 175 200 230 8 8 10 12 Designation/ size Technical data CP 644 firestop jacket CP 643-50/1.5”N CP 643-63/2”N CP 643-75/2.5”N CP 643-90/3”N CP 643-110/4”N CP 643-125/5”N CP 643-160/6”N CP 644-180/7” CP 644-200/8” CP 644-225/9” CP 644-250/10” DIN 4102 BS 476:Part 20, 1987. Insulation/integrity 1 1 1 1 1 1 1 1 1 1 1 UL 2079, UL1479 (ASTM : E 814) Item no. 304325 304326 304327 304328 304329 304330 304331 304339 304340 304342 304343 FM 57 Construction chemicals and Firestop systems CP 648E, CP 648S Firestop wrap strip Product performance Product description Special elastic material for good pliability High performance intumescent Plasticizer-free firestop material (foams and Halogen-free expands in fire) Water resistant installation Integrated adhesive closing tape Acoustic insulation tested Internationally tested; up to 4 hour fire rating 10 m long for any applications (648-E) Long length helps avoid material waste (648-E) Continuous wrapping for numerous layers (648-E) Fewer installation errors: precut and lengthoptimized for specific pipe diameters (648-S) Technical data Chemical basis : Density : Storage Temperature : Application temperature : Temperature resistance : Expansion in the case of fire : Expansion rate : Construction material class : Durability : Acoustic test : Acrylic polymer 1.3 g/cm3 -5 to + 30°C -5 to + 40°C -20 to + 100°C above 160°C 1:40 B2 (DIN 4102) >30a According to DIN EN 2014010; ISO 14010; DIN 52210 System advantages/customer benefits Extremely thin wrap thickness Simply insert wrap thickness Minimum space required - ideal for limited penetration accessibility (ideal for bent pipes etc.) Easy to fasten with integrated adhesive closing tape CP 648-E Applications Sealing pipes from 1.5” (32 mm) up to 6” (170mm) in penetrations through fire rated floor compartments. Tested and approved in accordance with BS 476 Part 20: 1997, UL 1479 and ASTM E814 Suitable for plastic, insulated and non-insulated metal pipes Product features One-step installation No additional caulking Economical in use with short installation time Easy to remove and replace pipe Allows for pipe adjustments during installation Technical data Expansion temperature : Expansion rate : Temperature resistance : Colour : >200°C/392°F 1:100 (Free expansion) Maximum 100°C/212°F grey exterior CP 656 Firestop plug Applications System advantages/customer benefits Sealing circular penetrations Especially suitable for laying new Tempory or permanent sealing cables later Economical in use owing to short of single or bunched cables in installation time fire walls and floors. Easy installation as no special tool is Product description required Ready-to-use, intumescent Immediately functional after installation flexible plugs based on a two Versatile in use (temporary or permanent component polyurethane foam protection) Absolutely dust and fiber free Smoke and gas tight Technical data Density : Application temperature : Colour : Temperature resistance : Expansion temperature : Expansion ratio (at 300°C) : Material class as per DIN 4102, P.1 : approx. 0.25 g/cm3 -5°C to +40°C Red -60°C to +60°C +300°C 1:5 B2 CP 648-S CP 648-S Ordering designation Packaging contents CP 648-E-W45/1.8”x10m Firestop endless wrap CP 648-S 50/1.5” Firestop single wrap CP 648-S 63/2” Firestop single wrap CP 648-S 75/2.5” Firestop single wrap CP 648-S 90/3” Firestop single wrap CP 648-S 110/4” Firestop single wrap CP 648-S 125/5” Firestop single wrap CP 648-S 160/6” Firestop single wrap DIN 4102 CP 680 Cast-in firestop device 1 2 2 2 2 2 2 2 Item no. 304310 304296 304297 304298 304299 304300 304301 304302 UL 2079, UL1479 (ASTM : E 814) BS 476:Part 20, 1987. Insulation/integrity Examples Waste water pipes Fresh water pipes New buildings in construction phase Computer centers, hospitals and laboratories Ordering designation Packaging contents CP 680 -75/2.5” CP 680 -110/4” CP 680 -160/6” BS 476:Part 20, 1987. Insulation/integrity Item no. 1 1 1 Product features Completely free from dust and fibers Halogen and solvent free Operatonal immediately after installation Can be painted with dispersion, acrylate or silicone Ordering designation CP 656-62 Plug, 62 mm dia. CP 656-77 Plug, 77 mm dia. CP 656-107 Plug, 107 mm dia. CP 656-132 Plug, 132 mm dia. CP 656-158 Plug, 158 mm dia. CP 656-202 Plug, 202 mm dia. 333545 333546 333547 FM UL 2079, UL1479 (ASTM : E 814) DIN 4102 58 CP 648-E CP 656 Bran dsch sodfm utzs topf Z8Z2 ,ev iJdjfi en whriu 3awö 4i5ki h. rdwil p3i4eß028 NöoW oi4jtf E u9+ß -öx-. 8u27 uze 12oe vbvb oo vh, ireiv Packaging contents 20 20 20 20 20 20 BS 476:Part 20, 1987. Insulation/integrity Item no. 220211 220239 220212 236977 220213 220214 FM Construction chemicals and Firestop systems CP 651 Firestop cushion Applications Medium-sized and large penetrations Temporary or permanent sealing of cable and cable tray penetration Product description Ready-to-use firestop cushion made of a homogeneous, graphitebased, intumescent granulate mixture (which foams and expands in a fire) all contained in an inner polyethylene bag inside an outer, protective woven fibre glass bag. Technical data Density : Weight : CP 651-L CP 651-S CP 651-XS Dimensions (LxWxH) : CP 651-L CP 651-S CP 651-XS Reaction temperature : First expansion Second expansion Temperature resistance : Material class as per DIN 4102, T.1 : approx. 0.33 g/cm3 750 g ± 10% 300 g ± 10% 150 g ± 10% 340x200x35 mm 340x100x25 mm 340x90x20 mm at + 150°C at + 600°C -40°C to + 120°C B2 FS 657 Firestop brick Applications Temporary or permanent sealing of Cables and cable trays in line Non-combustible metal, high grade steel or cast iron pipes and copper pipes Combustible pipes Fire seals where cables, steel, copper, cast iron or plastic pipes all pass through in the same opening (multiple penetration) in line Product description Ready-to-use, intumescent flexible bricks based on a two component polyurethane foam Technical data Density : Dimensions (LxWxH) : Application temperature : Temperature resistance : Expansion temperature : Expansion ratio (at 600°C) : Product features Dust free and tear-resistant Suitable for temporary and permanent installations Durable and resistant Product features Completely free from dust and fibres Halogen and solvent free Operational immediately after installation Can be painted with dispersion, acrylate or silicone approx. ca. 0.25 g/cm3 200x130x50 mm >5°C -15°C to+60°C 149°C 1:5 Ordering designation CP 651-L Firestop cushion L/W/H: 340x200x35 mm CP 651-S Firestop cushion L/W/H: 340x100x25 mm CP 651-XS Firestop cushion L/W/H: 340x90x20 mm Applications Protection of cables, bunched cables on cable trays. Product features Segments of application: Remains flexible when dry Oil and gas (CP 679A) Water based Offshore Easy to clean Petrochemical Odourless Power plants Technical data Density : Colour : Consistency : Coverage rate : 1 mm dry Application temperature : Dust dry : Touch dry : Full cure : Temperature resistance : Application of 2 nd layer : Shelf-life after production : CP 678 approx. 1.3 g/cm3 white 225585 10 225586 20 225587 UL 2079, UL1479 (ASTM : E 814) System advantages/customer benefits Especially suited for re-penetrations or new penetrations Economical in use with short installation times Easy installation as no special tool is required Immediately functional after installation Absolutely dust, fibre, halogen and solvent free Smoke and gas tight Wide application range (base materials, services, S90-S30) For combustible pipes no additional collar is needed Ordering designation Packaging contents FS 657 Firestop brick Item no. 26 306241 UL 2079, UL1479 (ASTM : E 814) System advantages/customer benefits Ready-to-use For external applications (CP679A) Water resistant Resistant to oil and petrol spills Simple application using a paint brush, roller or airless apray gun (recommended tip size 0.58 to 0.63 mm) CP 679A approx. 1.35 g/cm3 white Can be applied by paint brush, roller or sprayed =1.8 kg/m2 +5°C +40°C 4 hours -30°C+ 80°C after 4 h. 12 months Item no. 5 BS 476:Part 20, 1987. Insulation/integrity FM CP 678 Intumescent cable coating CP 679A Ablative cable coating Packaging contents =1.7 kg/m2 +5°C +45°C 3 hours 6 hours 24 hours -20°C+ 80°C after 24 h. 12 months Ordering designation CP 678 Firestop cable coating 20 kg bucket CP 679A Firestop cable coating 20 kg bucket Packaging contents Item no. 1 334892 1 372097 Internationally tested in accordance with / approved by: American Bureau of Shipping, Certificate of Product Design Assessment.(CP 679A) IEC 332 Part 3 and IEC 331 FM 59 Construction chemicals and Firestop systems CP 618 Firestop putty stick Applications Single or bundled cables Non-combustible pipes Blank openings Base materials Concrete wall/floor Gypsum wall System advantages/ customer benefits Reusable Easy to add or subtract cables Fast installation time Example Telecommunication and data line penetration of gypsum wall assemblies Steel conduit and EMT penetration of concrete and block wall assemblies Blank openings in concrete and block wall assemblies Technical data Dimensions : Consistency : Colour : Application temperature : Curing rate : Density : Intumescent activation : Surface burning characteristics : (ASTM E 84-96) 18 cu. in. Moldable putty Red 5°C to 35°C Non-curing Approx. 1.48 g/cm3 Approx. 104°C to 121°C Flame spread: 5 Smoke Development: 5 Clean plastic pipe Slice CP 618 to be packed into opening from stick Pack in CP 618 Ordering designation Packaging contents CP 618 Firestop putty stick UL 2079, UL1479 (ASTM : E 814) Smooth CP 618 12 Fasten installation plate (if required) Item no. 314721 FM CF 116-45 Filling foam uses Filling Wall tie hole Stair joints Breaches in walls Pre-cast components Holes left by concrete forms Insulation Shower trays Water pipes Attics Joints around windows frames Instructions for use May be applied using the CF-FA1 finger adaptor or CF-GA1/GR1 grip system Technical data Single-component polyurethane foam Chemical basis : Contents of can (quantity filled) : 750 ml Foam yield (freely foamed) : up to 45 litres Minimum temperature Can : +5°C Substrate/ambient : +5°C Non-tacky after : 10-12 min. Ready to cut/ plaster over after : approx. 30 min. Temperature resistance of cured foam : -30°C to+ 80°C Fire rating as per DIN 4102 : B2 Shelf life (at +20°C, protect form frost) : 9 months Please refer to the technical data sheet and safety data sheet. CF-F 750 Filling Foam Filling Pipe penetrations Backfilling Breaches in walls Holes left by concrete forms Technical data Chemical basis : Building material class : (DIN 4102) Colour : Foam yield (freely foamed) : Curing: Non - tacky (after) : Ready to cut (after) : Load can be applied (after) : Tensile strength : Shear strength : Thermal conductivity : Gross density (full expansion) : Temperature resistance of cured foam : Application temperature range : Storage and transportation temperature : 60 Insulating Joints around window frames Attics Drywall Water pipes Sigle - component polyurethane foam B3 yellowish up to 34 I (CF-F), upto 50 l (CF-I) approx. 10 mm. approx. 30 mm. approx. 3-5 hrs. approx. 6 N/cm2 approx. 6 N/cm2 0.04 W/mK approx. 25 kg/m3 -40°C to+80°C +5°C to+30°C +5°C to+25°C System advantages Cantains no CFC’s High foam yield-up to 45 litres Easy to apply using finger adaptor or grip system Contains no formaldehyde or PCB No substances harmful fo health are releaed after complete curing, neutral odour Does not rot or deteriorate with age Fire rating B2 - as per DIN 4102 Precision plastic valve (gold valve) for functional reliability due to reduced gas pressure loss long shelf life - constant product quality Reusable system components Ordering designation CF 116-45 Filling foam CF FA1 Finger adapter CF GR1 Grip CF GA1 Grip adapter CF R1 Cleaner Packaging contents 12 12 1 12 12 Item no. 307219 259766 259764 259765 55019 Product features Contains no CFC’s Easy to apply using finger adaptor Contains no formaldehyde ar PCB Does not rot or deteriorate with age Long shelf life - constant product quality No substances harmful to health are released after complete curing, neutral odour Ordering designation CF-F 750 1C Filling foam CF-I 750 1C Insulation foam Packaging contents 12 12 Item no. 369811 369801 Construction chemicals and Firestop systems Contact us for: Technical sales representative Customer service Hilti service center Technical advice / engineering support Customer Service Repair Center Service Delivery Service Electronic Service 021 3983 6881 031 843 9114 021 3983 6881 021 3983 6881 031 843 9114 E-mail [email protected] Web Site www.hilti.com Expertise in every case. PT.HILTI NUSANTARA JAKARTA : Plaza Kebon Sirih Podium 2 unit 07-08 Jalan Kebon Sirih No. 17-19, Jakarta 10340 Tel : (021) 3983 6881 (Hunting) Fax : (021) 392 0345 E-mail : [email protected] SURABAYA : JL. Raya Kutisari No. 54 - 56 Kav. 7 Surabaya Indonesia Tel / Fax : (031) 843 9114 Website : www.hilti.com Applications and products 2004