Preview only show first 10 pages with watermark. For full document please download

Applied Systems Catalogue_lr_ecpen11

   EMBED


Share

Transcript

Applied systems All Seasons Climate comfort Heating Air Conditioning Applied Systems Refrigeration Catalogue No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system to suit your requirements. It is a system that has proved its worth in a multiplicity of situations - from industrial sites to retail warehouses, hotels and department stores. The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to produce complete ranges of water chillers — genuinely optimised for use with R-134a, R-407C and R-410A refrigerants. Daikin chillers offer the ultimate in flexibility and control — a reflection of the advanced technology inherent within them. Unique in their precision, power, low operating noise, easy maintenance and low running costs, Daikin chillers represent the sure and safe route to an indoor environment that is comfortable, clean and consistent. As a manufacturer that makes its own refrigerant and compressors, Daikin has total control at the production stage. Daikin also offers a complete range of air handling units to meet modern day requirements for better indoor air quality and increased insulation standards. It is this unique combination of advanced technology, experience and reliability that makes Daikin the obvious choice and long term solution for the professional. Table of Contents PRODUCT PORTFOLIO - Air cooled 04 condensing unit 76 PRODUCT PORTFOLIO - water cooled 06 WATER COOLED 82 options portfolio 08 condenserless chiller 106 accessories portfolio 10 D.I.C.N. 116 About daikin 12 Hydraulic module & buffer tank 117 ENVIRONMENTAL AWARENESS 13 FAN COIL UNITS 118 Heat recovery 14 AIR handling units 134 reliable & efficient  16 MEASURING CONDITIONS 140 AIR COOLED 18 3 Condensing units sCRew R-134a eRAD120-460e-sL 4 1 1 1 1 ewAD330-520bzss/sL 330 329 ewAD330-520bzxs/xL/xR 330 329 2 ewyD250-580bzss 1 1 1 1 1 2 2 1 2 2 2 1 2 2 2 2 2 22 2 2 2 ewAD670-C18Czxs/xL ewAD640-C17CzxR ewAD650-C20C-ss/sL ewAD620-C19C-sR ewAD760-C22C-xs/xL ewAD740-C22C-xR ewAD820-C16C-Ps/PL ewAD810-C16C-PR 1 1 320 321 2 2 2 2 2 320 322 ewAD250-620D-xs 2 310 312 300 296 1 2 2 2 2 2 324 320 324 260 261 280 275 300 298 2 2 280 278 310 307 260 256 258 240 236 281 250 252 260 254 230 231 2 320 316 2 290 286 300 299 310 309 2 2 324 2 280 275 300 302 2 250 247 250 249 1 300 296 2 250 245 1 250 252 1 270 272 2 240 238 2 250 253 270 265 270 271 1 2 310 306 ewAD240-600D-xR 240 243 225 210 211 210 209 180 183 180 182 199 2 230 234 2 2 270 270 266 270 270 273 260 256 270 274 290 289 290 291 290 292 297 297 250 254 2 2 310 306 ewyD250-570bzsL 250 248 1 230 225 1 220 219 180 183 1 210 214 2 230 231 1 2 2 300 295 1 1 2 250 252 ewAD210-490D-sx 210 203 1 165 1 160 163 14 010 9.5 011 11 013 13.2 17.5 240 243 ewAD200-590D-Hs 200 195 210 208 1 2 2 220 219 1 2 2 210 209 1 200 198 1 2 190 190 1 2 200 196 1 160 157 1 180 177 1 190 187 ewAD180-530D-sL 180 184 2 210 209 ewAD180-530D-sR 180 177 2 170 165 2 2 130 131 1 1 150 152 1 1 1 130 136 149150 145 1 2 140 138 1 1 1 1 2 120 121 1 1 100 100 100 105 1 1 114 eUwA*5-24kbzw1 1 54 1 8 18.4 10 23.8 1 17.1 8 19.7 21 10 22.5 25 12 26.5 34.2 16 34.6 40 20 46.6 24 50 24 55.3 1 11.5 1 13 009 8.5 007 7.1 006 6 011 11 011 11.0 1 160 159 eRAD120-490e-ss 1 140 144 ewAD100-400e-sL 1 120 116 ewyQ080-250DAyn 1 130 134 ewAD100-410e-ss 100 101 080 80 R-410A 080 77 ewAQ080-260DAyn 1 1 87.7 eUwy*5-24kbzw1 1 8 1 10 1 010 9.5 009 9 ewAQ009-013ACw1 1 1 12.5 013 13.2 1 1 011 11 ewyQ005-007ACV3 1 18.5 10 24 12 27 16 37 20 46 1 11 ewyQ009-013ACw1 009 9 ewyQ009-011ACV3 1 7.75009 8.5 ewAQ009-011ACV3 1 007 7.1 0 140 137 sCRew R-134a 120 121 ITs 100 97.9 sCROLL 5 11.6 R-407C eUwAC5-10Fbzw1 5 11.3 sCROLL R-410A 11.9 9.1 swIng Packshot 005 5.2 ewAQ005-007ACV3 006 6 sCROLL R-410A Reference 005 5.2 Refr. Mode 6.35 swIng 5 O Compr. 5.65 Type 120 116 AIr cooled Product portfolio air cooled 1 200 1 1 1 1 1 2 2 2 2 2 1 1 ewAD390-580D-ss 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 956 1,053 1,132 C12 1,251 C13 1,359 1,439 1,521 2 2 2 2 2 2 2 2 2 960 C10 C11 C13 C14 C15 C16 2 2 2 2 2 2 2 2 2 2 2 3 2 3 3 2 2 1 1 5 3 3 1,901 1,953 2,008 3 1,902 C21 1,959 C22 1,802 1,875 1,922 3 3 C17 1,714 C18 1,795 C19 1,833 C20 3 1,854 C20 1,714 C17 1,712 C17 1,709 3 3 C20 1,768 C18 1,858 C19 3 3 3 3 3 C21 C22 3 C20 3 C18 C16 1,631 C16 1,622 3 C18 1,802 3 1,813 C19 2 1,722 3 1,622 3 3 C19 C15 3 2 1,623 C16 2 1,685 3 1,556 C12 1,235 2 3 C18 2 2 C17 2 C15 C12 1,236 C11 1,170 C10 1,037 C11 1,095 900 902 2 1,596 C16 2 1,639 C16 2 1,550 C10 1,031 980 976 2 C13 1,308 C13 1,332 1,418 1,419 C14 1,443 C14 1,450 1,538 C15 1,545 C15 1,545 2 C14 2 1,418 H14 2 C17 2 1,321 1,319 2 1,562 C16 C13 1,152 2 1,525 H14 1,409 1,064 2 H14 H15 967 2 1,474 2 1,349 C13 C12 C11 912 830 832 2 C16 2 2 C15 2 1,302 C13 1,367 1,468 2 1,270 1,112 2 1,280 C12 C11 C10 970 910 2 C14 2 2 2 C13 H14 1,390 H15 2 2 C12 2 920 2 1,268 C11 1,247 2 1,020 922 2 2 1,279 C12 2 1,001 2 C10 1,041 2 C10 990 850 852 2 1,158 C11 1,074 974 2 970 876 2 880 2 C11 975 2 889 2 980 2 890 2 866 2 870 790 789 2 890 832 2 890 830 2 875 789 2 790 3 830 2 615 3 830 3 570 567 457 480 478 450 448 580 510 505 510 514 530 520 522 550 547 558 475 3 811 3 3 810 2 3 583 590 587 2 821 2 2 3 3 880 820 2 2 740 738 2 2 3 615 3 490 493 510 510 2 2 744 2 530 558 2 3 600 600 560 561 510 512 460 455 2 740 2 2 2 809 756 2 2 460 2 463 2 620 622 580 575 520 524 470 469 2 810 760 670 672 2 440 436 2 475 2 443 2 2 2 700 700 2 2 715 2 2 720 520 515 520 515 2 2 400 404 440 440 480 477 510 505 530 533 400 404 440 440 480 477 510 505 530 533 490 492 450 451 410 413 2 736 490 488 2 2 2 560 556 510 502 530 532 470 466 440 436 390 389 580 578 2 647 2 490 488 2 2 443 450 448 463 2 400 401 2 2 2 2 740 650 460 459 2 640 635 2 2 2 2 2 619 2 460 459 2 2 2 620 420 423 2 2 420 415 370 366 370 370 2 490 488 2 420 423 2 410 410 413 370 370 310 312 400 398 350 345 1 430 425 2 400 403 2 2 380 376 2 2 2 410 22 330 327 350 351 2 320 321 2 300 299 310 309 410 413 360 360 310 307 1 460 462 2 400 395 2 350 345 370 370 320 322 280 275 300 302 2 2 440 435 2 400 395 2 324 320 324 333 340 339 340 336 349 370 365 379 380 382 380 381 300 296 2 2 410 409 2 2 370 370 2 320 316 324 333 330 331 349 360 355 379 370 372 2 360 358 290 289 310 306 2 330 329 290 292 2 360 358 297 2 330 329 290 291 297 2 350 352 310 306 500 1,000 2,000 kw = Cooling only = heating only = heat pump = heating = Cooling 1 1 2 2 2 2 2 2 2 2 3 2 3 3 2 3 2 3 3 3 3 3 3 3 Product portfolio water cooled 168 177 186 195 226 175 237 185 400 465 367 391 416 360 380 372 403 456 380 494 420 431 450 342 330 317 444 2 354 326 1 2 394 1 388.4 340 1 1 433 362 400 1 ewwD340-C18I-ss 434 460 420 2 333 1 408 2 400 2 380 366 2 2 2 380 1 sCRew 1 360 ewwD360-C12I-xs 440 1 411 water cooled 2 327 334 410 320 320 343 300 2 2 307 280 227 300 1 1 2 1 264 220 230 1 R-134a 1 280 253 1 1 2 2 2 1 310 260 210 1 190 ewwD190-650g-xs 1 186 170 1 1 1 260 204 170 ewwD170-600g-ss 1 1 247 210 1 290 216 201 166 1 2 310 2 280 2 320 2 285 256 6 250 1 208 6 6 210 6 223 6 1 6 6 6 248 195 6 1 6 195 6 183 4 4 1 120 ewwD120-560J-ss 175 185 4 6 180 4 4 4 121 4 155 143110 154 120 165 130 110 2 4 120 130 2 4 214 165 112 121 130 126 100 100 2 4 165 86 99 110 090 090 1 1 54.8 045 71.4 055 82.7 065 1 2 065 1 2 142 21 28 32 43 56 65 35.4 028 41.2 035 369 445 460 464 ewwD380-C11bJynn 380 1 380 1 ewwQ380-C20b-ss 1 1 380 1 460 D ewwP014-065kbw1n ewwP090-195kbw1n 2 140 140 145 181 145 159 147150 155 198 155 1 1 1 014 sCROLL R-407C 200 1 27.3 022 17.5 028 035 045 055 0 022 Packshot 13 Reference 16.6 Refr. Mode 014 Type Compr. 422 R-410A ewwQ420-C21b-xs ewwD320-C10Fzxs 430 1 320 1 300 CenTRIR-134a FUgAL 429 317 420 1 DwsC 1 20 26.8 31.2 40 53.7 62.4 045 055 065 6 429 383 430 428 381 390 2 428 420 356 380 2 1 1 420 320 1 Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), liquid Chilling packages (lCp) and fan coil units (fCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com 360 2 2 391 ewLD320-C17I-ss 2 400 320 2 328 1 2 352 316 1 1 270 330 2 360 307 328 286 265 265 310 237 235 2 244 2 280 2 240 160 1 2 290 192 2 189 ewLD160-550g-ss 195 1 165 1 161 1 190 143 1 164 128 2 145 2 130 2 110 1 1 1 110 1 ewLD110-530J-ss sCRew R-134a 020 026 030 ewLP012-65kbw1n 12.1 Condenserless chiller sCROLL R-407C 012 DwDC Air cooled: Eurovent certified up to 600kW Water cooled: Eurovent certified up to 1500kW Nominal cooling capacities are based on Eurovent condit Evaporator: 12°C/7°C — Ambient: 35°C Nominal heating capacities are based on Eurovent condit Ambient: 7°CDb/6°CWb — Condenser: 40°C/45°C 391 428 1 504 596 657 730 788 850 919 966 1,033 1,078 1,125 1,188 1,267 1,319 1,370 1,422 1 400 420 500 600 650 750 800 850 900 950 C10 C11 C12 C13 C14 C15 C16 C17 381 2 476 480 474 00kW o 1500kW on Eurovent conditions: °C on Eurovent conditions: er: 40°C/45°C 2 2 1 856 1,048 860 2 C10 1 2 2 2 2 ECpEN11-404 • 500 • 03 /11 • Copyright © Daikin The present publication supersedes EpCEN10-404. printed on non-chlorinated paper. prepared by la movida. belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300. b-8400 oostende 1 2 2 1 2 1,055 2 2 2 1 2 2 2 3 3 1 3 1,460 1,888 2,050 C15 C16 C17 C19 C20 1,449 1,573 1,733 1,863 2,020 2 3 2 2 2 3 2 2 3 3 2 2 2 2,152 2 1,346 C17 1,730 1,790 1,661C18 1 C21 1,274 1,363 1,427C15 1,507 1,227 C16 C14 1,161C12 1,217C13 1 1 1 1 C20 1,134 1,510 3 3 C19 2 1,401 1,455 1,155 1,204 3 C17 1,203 1,313 3 1,584 1,748 C12 712 3 3 C16 2 C15 C14 2 1,126 910 844 782 986 1,027 950 900 850 800 705 2 2 993 C10 1,038 1,072 1 1 C14 2 1,369 1,255 1,325 2 C13 2 1,185 976 C10 1,069C11 2 1,270 2 1 C13 1,050 2 C12 C11 976 1 C11 1 1,158 1 C10 990 2 1,116 1 933 919 1 950 2 C12 1,007 2 908 866 2 C10 2 960 960 2 850 1 2 C11 1 2 1,037 1 2 895 1 823 795 832 757 1 800 2 900 1 816 734 700 2 C10 1 850 750 1 2 796 1 2 862 872 860 870 973 1 800 1 720 2 750 2 970 1 801 1 727 674 600 604 431 505 2 556 580 655 617 2 800 1 730 638 2 640 585 650 2 725 650 1 730 1 2 660 1 630 2 600 541 2 637 2 524 550 2 2 640 1 573 494 610 500 482 500 500 496 2 600 448 552 460 460 403 2 639 1 577 538 460 1 640 1 538 1 506 460 1 550 460 460 444 434 460 2 500 1 433 494 420 2 416 513 500 530 560 465 450 400 542 571 2 9,000 4,500 635 640 521 550 1 493 440 2 562 445 1 460 1 560 464 1 2 600 521 520 460 2 516 422 408 420 2 400 354 2 520 420 394 2 502 530 429 1 430 400 388.4 2 500 530 429 2 470 411 2 526 383 2 430 390 2 550 428 2 420 380 500 1,000 2,000 2 2 2 2 2 3 7 9,000 kw = Cooling only = heating only = heating = Cooling 2 3 2 1 1 1 2 2 2 2 2 1 2 2 OPTIOns PORTFOLIO options portfolio OPTIOns PORTFOLIO Type Type Compr. Compr. Refr Refr swIng swIng R-410A R-410A Mode Mode Air Cooled Air Cooled Products Products 005-006-007 005-006-007 009-010-011 005-006-007 009-011-013 009-010-011 009-010-011 009-011-013 009-011-013 009-010-011 5-8-10 009-011-013 5-8-10-12-16-20-24 5-8-10 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 080-100-130-150-180-210-240-260 5-8-10-12-16-20-24 080-100-130-150-180-210-240-260 080-100-130-150-180-210-240-260 014-022-028-035-045-055-065 014-022-028-035-045-055-065 012-020-026-030-040-055-065 012-020-026-030-040-055-065 sCROLL sCROLL R-407C R-407C ewAQ-ACV3 ewyQ-ACV3 ewAQ-ACV3 ewAQ-ACV3 ewyQ-ACV3 ewAQ-ACw1 ewAQ-ACV3 ewyQ-ACV3 ewAQ-ACw1 ewyQ-ACw1 ewyQ-ACV3 eUwAC-Fbzw1 ewyQ-ACw1 eUwAn-kbzw1 eUwAC-Fbzw1 eUwAP-kbzw1 eUwAn-kbzw1 eUwAb-kbzw1 eUwAP-kbzw1 eUwyn-kbzw1 eUwAb-kbzw1 eUwyP-kbzw1 eUwyn-kbzw1 eUwyb-kbzw1 eUwyP-kbzw1 ewAQ-DAynn eUwyb-kbzw1 ewyQ-DAynn ewAQ-DAynn ewyQ-DAynn ewwP-kbw1n ewwP-kbw1n sCROLL sCROLL R-407C R-407C ewLP-kbw1n ewLP-kbw1n R-410A R-410A CondenCondenwater water serless serless Cooled Cooled chiller chiller Reference Reference sCROLL sCROLL R-407C R-407C R-410A R-410A Nomenclature for air-cooled b and C series: Nomenclature for air-cooled b and C series: E W A D 4 6 0 b Z X S 1 2 3 4 5 6 7 8 9 10 11 E W A D 4 6 0 b Z X S 1 2 3 4 5 6 7 8 9 10 11 9 Inverter non-inverter 9 -:Inverter inverter -:Z: non-inverter Z: inverter p: premium Description code Description Total heat recovery Total Total heat heat recovery recovery 1 circuit Partial heatrecovery recovery1 circuit Total heat Direct line starter Partial on heat recovery wye delta starter (y - d) Direct on line starter soft starter wye delta starter (y - d) Heat pump version soft starter brinepump versionversion Heat Double set point brine version Compressor thermal relays Double set point Fans circuit Compressorbreakers thermal with relaysthermal overload relays Phase monitor Fans circuit breakers with thermal overload relays Inverter compressor starter Phase monitor Under Inverter/ overvoltage compressor control starter energy/meter Under overvoltage control Capacitors cosfi 0.9 energy meter Current limit - display Capacitors cosfi 0.9 evaporator Current limitvictaulic - displaykit evaporator ange kitkit evaporator fl victaulic evaporator waterbox VICTAULIC (1 Pass) evaporator Marine flange kit evaporator marine waterbox VICTAULIC victaulic (2 (1 step) evaporator Marine waterbox Pass) evaporator marine evaporator marine waterbox waterbox victaulic victaulic (3 (2 step) step) evaporator Marine waterbox FLAngeD (1 Pass) evaporator marine waterbox victaulic (3 step) evaporator waterbox FLAngeD flanged (2 (1 step) evaporator marine Marine waterbox Pass) evaporator evaporator marine marine waterbox waterbox fl flanged anged (3 (2 step) step) Condenser anges kitflanged (3 step) evaporator double marine fl waterbox evaporator double water side design Condenser flanges kit pressure 10 bar evaporator water water side side design design pressure pressure 10 25 bar bar evaporator 20 mm evaporator insulation evaporator water side design pressure 25 bar Axial fans 100 pa liftinsulation 20 mm evaporator Axial fans fans 100 250 pa pa lift lift Axial 20mmfans condenser insulation Axial 250 pa lift Fan silent mode 20mm condenser insulation Fans speed control Fan silent mode device (phase cut on fan) Condenser kit Fans speed victaulic control device (phase cut on fan) Condenser ange kitkit Condenser fl victaulic Condenser waterbox VICTAULIC (1 Pass) Condenser Marine flange kit Condenser Condenser Marine Marine waterbox waterbox VICTAULIC VICTAULIC (2 (1 Passes) Pass) Condenser Condenser Marine Marine waterbox waterbox VICTAULIC VICTAULIC (3 (2 Passes) Passes) Condenser FLAngeD (1 Condenser Marine Marine waterbox waterbox VICTAULIC (3Pass) Passes) Condenser Condenser Marine Marine waterbox waterbox FLAngeD FLAngeD (2 (1 Passes) Pass) Condenser Condenser Marine Marine waterbox waterbox FLAngeD FLAngeD (3 (2 Passes) Passes) speedtrol Condenser Marine waterbox FLAngeD (3 Passes) (fan speed control device on/off up to -18°c) speedtrol Condenser coil guards (fan speed control device - on/off - up to -18°c) evaporator coil areaguards guards Condenser Cu-cu condenser coil evaporator area guards Cu-cu condenser sn condenser Cu-cu coilcoil Condenser water side design 16 bar Cu-cu sn condenser coil code 01 02 01 03 02 04 03 05 04 06 05 07 06 08 07 10 08 11 10 12 11 13 12 14 13 15 14 16 15 17 16 19 17 20 19 21 20 22a 21 22 22a 23 22 24a 23 24 24a 25 24 26 25 27 26 28 27 29 28 30 29 32 30 33 32 34 33 35 34 36 35 37 36 38a 37 38 38a 39 38 40a 39 40 40a 41 40 Condenser water side design 16 bar 10 Efficiency level Standardlevel 10S:Efficiency X: Standard high S: p: high premium X: Option Option sTD Option Option sTD Option sTD sTD sTD 47 sTD sTD sTD sTD Option sTD Option Option Option Option sTD Option Option sTD • • • ewwD~I-xs ewwD-J-ss ewwD~g-xs eRAD~eewLD~g-ss ewLD~I-ss ewwD~Fzxs ewAD~C ewwD~I-ss ewLD-J-ss ewwD~g-ss ewwD~I-xs ewwD-J-ss ewwD~g-xs eRAD~eewLD~g-ss ewLD~I-ss ewwD~Fzxs ewAD~C ewwD~I-ss Option ewwD~g-ss Option Option (9) Option ewLD-J-ss Option Option Option Option Option sTD Option sTD Option sTD Option sTD Option Option sTD Option Option sTD Option Option sTD Option Option sTD sTD Option sTD sTD Option Option sTD Option Option sTD sTD Option sTD sTD Option Option sTD Option Option sTD sTD Option sTD sTD Option sTD Option sTD Option Option Option Option sTD Option Option sTD Option Option sTD Option Option sTD Option sTD Option sTD sTD Option Option Option Option Option Option Option sTD (2) Option Option sTD (2)(2) sTD Option Option Option Option Option Option Option sTD Option Option Option Option Option Option Option Option Option Option sTD sTD Option Option Option Option Option Option Option sTD Option sTD Option Option sTD Option sTD Option (9) Option Option sTD Option sTD Option Option Option Option sTD Option Option Option sTD sTD sTD Option (2) CF (2) Option CF CF Option CF Option Option CF Option sTD sTD Option Option Option Option Option Option sTD Option sTD sTD sTD sTD sTD Option Option Option Option Option Option Option sTD Option sTD Option Option Option Option Option Option Option sTD Option sTD Option Option Option Option Option Option Option sTD Option sTD Option Option Option Option Option Option Option sTD Option sTD sTD sTD sTD sTD Option sTD Option sTD Option Option Option Option Option sTD Option sTD Option Option Option Option Option (3) Option Option Option Option(3) Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option sTD sTD sTD Option Option Option Option Option Option Option sTD Option Option sTD Option sTD CF sTD Option CF Option Option Option Option Option Option sTD Option sTD Option Option (17) Option (17) sTD sTD sTD sTD Option Option Option (17) Option Option Option Option (17) sTD Option sTD Option Option Option Option Option Option Option Option Option Option Option Option sTD (17) Option Option Option Option Option Option Option sTD sTD 8 Option Option sTD Option Option sTD sTD Option sTD sTD sTD CF sTD Option CF (17) Option Option (17) sTD Option Option sTD Option 4. Option 56 is ‘sTD’ for ewAD180-200D-sL; ewAD180-190D-sR; ewAD200-210D-Hs 5. ‘High manometer’ per circuit 4. One Option 56 pressure is ‘sTD’ forside ewAD180-200D-sL; ewAD180-190D-sR; ewAD200-210D-Hs 6. Low‘High lift 8m – highside lift 12m (nominalper condition) 5. *One pressure manometer’ circuit * Option 80/81 is ‘n/A’ for ewAD180-190D-sR; 78/79/80/81 is ‘n/A’ for ewAD-D-sx 6. * Low lift 8m – high lift 12m (nominal condition) version * Option 80/81 is ‘n/A’ for ewAD180-190D-sR; 78/79/80/81 is ‘n/A’ for ewAD-D-sx 7. Option version 99 is ‘sTD’ for ewAD-D-sx version 8. Option not available for 2for smallest models 7. 99 is ‘sTD’ ewAD-D-sx version 9. efficiency range 8. not not available available for for high 2 smallest models 10. Tank delivered separately 9. not available for high efficiency range 10. Tank delivered separately sTD Option Option sTD Option Option sTD Option Option sTD CF sTD Option sTD sTD sTD Option sTD Option Option Option Option Option Option Option Option Option Option Option Option Option Option sTD Option Option sTD sTD Option Option sTD Option Option Option sTD Option sTD sTD Option sTD Option (2) Option sTD (14) sTD sTD (15) (14) sTD (15) ewAD~eewAD~eOption Option Option Option 1. Heat exchangers are placed in series 2. note the following option availability: 1. Please Heat exchangers are placed in series - groupnote 1: ewAD180-200D-sL; ewAD180-190D-sR; ewAD210D-sx; ewAD200-210D-Hs 2. Please the following option availability: -- group 2: all other models group 1: ewAD180-200D-sL; ewAD180-190D-sR; ewAD210D-sx; ewAD200-210D-Hs group 1 group 2 - group 2: all other models Option 20 group n/A 1 sTD 2 group Option n/A Option Option 21 20 n/A sTD Option 29 sTD Option Option 21 n/A Option 3. Option 42 is ‘n/A’ for ewAD-D-sx Option 29 sTD Option version 3. Option 42 is ‘n/A’ for ewAD-D-sx version • • • • • • • • • • • (2) Not available with option oplN Option (1) sTD Option sTD sTD Option Option • • • Option sTD Option sTD Option 41 42 42 43 44 43 45 44 46 45 47 46 • • • High esP pump High esP pump OPHP OPHP R: Reduced Option Option (13) Option sTD Option Twin pump contact Twin pump contact OPTC OPTC (s) op12 & op03 need to be added to meet Swedish national law 1992: 16 (1) op12 Impossible option opZh+opZl (s) & op03 needcombination: to be added to meet Swedish national law 1992: 16 (2) available with option oplN opZh+opZl (1) Not Impossible option combination: 11 Sound level Standard 11S:Sound level l: Standard low S: R: low Reduced l: ewAD-bz ewAD~Cz- ewwQ~b- ewAD~DewyD-bz ewAD-bz ewAD~Cz- ewwQ~b- ewAD~DewyD-bz Option (13) Option Option (1) Option Option Option (13) (13) Option Option (1) (1) Option Option Option Option (13) Option Option (1) (1) sTD sTD sTD sTD sTD sTD Option sTD Option (13) Option single pump contact single pump contact OPsC OPsC integrated Hydronics integrated Hydronics single pump Twin pump single pump Twin pump OPsP OPTP OPsP OPTP sTD sTD sTD sTD sTD sTD sTD sTD sTD sTD sTD sTD (17) Option Option Option Option Option Option Option Option Option Option CF CF sTD (1) sTD (1) 11. not available for standard efficiency range 13. Only availablefor forstandard ewAD~bz 11. not available effirange ciency range 14. Only Fan silent mode an option for ewyD~bzss 13. available forisewAD~bz range 15. Only for ewyD~bzsL, option for ewyD~bzss 14. Fan silent mode is an option for ewyD~bzss 16. not available for ewyD~bz 15. Only for ewyD~bzsL, option for ewyD~bzss 17. not not available available for for ewyD~bz condenserless range 16. 18. not Onlyavailable availablefor forcondenserless condenserlessrange range 17. *18. Option 76 is standard available for the versions with reduced / extra low sound level Only available for condenserless range * Option 76 is standard available for the versions with reduced / extra low sound level p p buffer tank buffer tank OPbT OPbT noise & Head Pressure control noise & Head Pressure control Low noise Inverter fans High esP fans Low noise Inverter fans High esP fans OPLn OPIF OPHF OPLn OPIF OPHF sTD sTD sTD • sTD • • • • • •(2) •(2) •(2) • • • • • • • High glycol High glycol OPzH OPzH • • • • • • • • lwe lwe Low glycol Low glycol OPzL OPzL • • • • • • • • • • • • • • • • • • evaporator heater tape evaporator heater tape OP10 OP10 sTD sTD sTD sTD sTD sTD sTD • • • • • • • • • ewAD-bz code ewAD~Cz- ewwQ~b- ewAD~D- ewAD~eewyD-bz ewAD-bz Description code ewAD~Cz- ewwQ~b- ewAD~D- ewAD~eCondenser water side design 21 bar 48 ewyD-bz Alucoat fi ns coil 49 Option Option Option Option Condenser water side design 21 bar 48 Cu-ni 90-10 tubes 50 Option Option Option Option Alucoat fins condenser coil 49 Option Condenser pass (dt 4-8 °c) 51 Cu-ni 90-101condenser tubes 50 Option Condenser 52 Condenser 2 1 passes pass (dt(dt 4-84-8 °c)°c) 51 Condenser °c) 53 Condenser 2 2 passes passes (dt (dt 9-15 4-8 °c) 52 Condenser 53b Condenser 3 2 passes passes (dt 9-15 °c) 53 Condenser 54 Condenser 4 3 passes passes 53b water pressure differential switch on condenser 55 Condenser 4 passes 54 water 56 Option (4) water pressure pressure diff differential erential switch switch on on evaporator condenser 55 evaporator electric heater switch on evaporator 57 sTD sTD Option sTD (4) sTD water pressure differential 56 Option evaporator fl ow switch 58 Option Option Option Option Option evaporator electric heater 57 sTD sTD Option sTD sTD Condenser fl ow switch 59 evaporator flow switch 58 Option Option Option Option Option electronic expansion device 60 sTD sTD sTD sTD sTD Condenser flow switch 59 Discharge line shut offdevice valve 61 sTD sTD Option sTD sTD electronic expansion 60 sTD sTD sTD sTD sTD suction line shut offoff valve 62 sTD Option Option sTD sTD Discharge line shut valve 61 sTD sTD Option sTD sTD High pressure side 63 Option Option sTD Option Option suction line shut offmanometers valve 62 sTD Option Option sTD (5) sTD Low 64 sTD sTD Highpressure pressureside sidemanometers manometers 63 Option Option sTD Option (5) Option Additional capacity reduction steps 65 Low pressure side manometers 64 sTD sTD Ambient outside temperature sensor Additional capacity reduction steps 65 67 sTD Option sTD and set-point reset Ambient outside temperature sensor 67 sTD Option sTD Hour run meter 68 sTD sTD sTD sTD sTD and set-point reset general contactor 69 sTD sTD sTD sTD sTD Hour runfault meter 68 sTD sTD sTD sTD sTD Container kit contactor 71 Option Option Option Option Option general fault 69 sTD sTD sTD sTD sTD Fork-lift kitkit 72 Container 71 Option Option Option Option Option wooden box packing 74 Fork-lift kit 72 Rubber 75 Option Option Option Option Option woodenanti boxvibration packing mount 74 sound system* mount 76 Option Rubberproof anti vibration 75 Option Option Option Option Option spring anti vibration 77 Option Option Option Option sound proof system*mount 76 Option One centrifugal pumpmount (low lift) 78 Option Option Option Option spring anti vibration 77 Option Option Option Option One lift) 79 Option Option Option One centrifugal centrifugal pump pump (high (low lift) 78 Option Option Option Option Two centrifugal pumps (low lift) 80 Option Option Option (6) Option One centrifugal pump (high lift) 79 Option Option Option(8) Two centrifugal pumps (high lift) 81 Option Option (6) Option Two centrifugal pumps (low lift) 80 Option Option Option (6) Option (8) (8) witness test 82 CF CF (6) Option CF (8) Two centrifugal pumps (high lift) 81 Option Option external tank without cabinet (500 l) 83 Option (10) Option Option witness test 82 CF CF CF external 84 Option Option external tank tank without without cabinet cabinet (1000 (500 l)l) 83 Option Option (10) (10) Option Option external l) with cabinet RAL7032 87 Option Option external tank tank (500 without cabinet (1000 l) 84 Option Option (10) (10) Option Option external withcabinet cabinetRAL7032 RAL7032 88 Option Option external tank tank (1000 (500 l)l)with 87 Option Option (10) (10) Option Option Acoustic test (1000 l) with cabinet RAL7032 89 CF CF CF external tank 88 Option (10) Option Option set-point reset, Acoustic test 89 CF CF CF 90 Option sTD sTD Option sTD demand limit and alarm from external device set-point reset, 90 Option sTD sTD Option sTD Double pressure relief valve with diverter 91 Option Option sTD Option Option demand limit and alarm from external device Low ambient kit for 1 circuit 93 Double pressure relief valve with diverter 91 Option Option sTD Option Option Low 94 Low ambient ambient kit kit for for 2 1 circuits circuit 93 Compressor 95 Option Option Option Low ambientcircuit kit forbreakers 2 circuits 94 Fans circuit breakers 96 sTD sTD sTD Compressor circuit breakers 95 Option Option Option Main switchbreakers interlock 97 sTD sTD sTD Fans circuit 96 sTD (16) sTD sTD sTD emergency 98 Option Main switchstop interlock 97 sTD (16) sTD sTD sTD Fan speed regulation 99 Option Option (7) emergency stop 98 sTD (16) Option Refrigerant recovery tank 100 Option Fan speed regulation 99 sTD (16) Option Option (7) evaporator water connection 101 Option Refrigerant right recovery tank 100 Option ground fault relay 102 Option evaporator right water connection 101 Option evaporator 1pass 103 ground fault relay 102 Option evaporator 2 passes 103a evaporator 1pass 103 103b evaporator 3 passes evaporator 2 passes 103a evaporator 3Double 104 evaporator passesFlange kit 103b Liquid receiver 105 evaporator Double Flange kit 104 Rapid restart 110 Option Liquid receiver 105 Rapid restart 110 Option Description 9 eRAD~eeRAD~eOption Option sTD sTD sTD Option sTD Option electrical electrical Main switch Main switch OP52 OP52 A / V meter A / V meter OP57 OP57 sTD sTD sTD • • • refrigerant refrigerant Dual pressure suction stop relief valve valvestop Dual pressure suction relief valve valve OP03 OP12 OP03 OP12 • • • condenser condenser Coil guards Coil guards OPCg OPCg •(s) •(s) •(s) • • • ewwD~I-xs ewwD-J-ss ewwD~g-xs ewLD~g-ss ewLD~I-ss ewwD~Fzxs ewAD~C ewwD~I-ss ewLD-J-ss ewwD~g-ss ewwD~I-xs ewwD-J-ss ewwD~g-xs ewLD~g-ss ewLD~I-ss ewwD~Fzxs ewAD~C ewwD~I-ss ewLD-J-ss ewwD~g-ss Option Option Option Option Option Option Option sTD (9) Option Option Option Option sTD sTD (17) sTD(11) (9) Option Option (9) sTD sTD (11) sTD (17) Option Option (9) sTD Option (11) Option Option sTD Option (11) Option Option sTD Option (17) Option sTD sTD Option Option sTD Option (17) Option Option Option Option Option Option sTD sTD Option Option Option Option Option Option Option Option Option sTD sTD sTD sTD sTD sTD sTD sTD Option Option Option Option Option sTD sTD sTD sTD sTD sTD sTD sTD sTD sTD sTD Option Option Option sTD Option Option sTD sTD sTD sTD sTD sTD sTD Option sTD sTD(9) sTD Option Option Option sTD sTD Option sTD (9) sTD sTD sTD sTD Option sTD sTD sTD sTD sTD sTD sTD Option sTD Option Option Option Option Option sTD sTD (11) sTD sTD (11) sTD sTD sTD sTD sTD sTD Option sTD sTD sTD sTD Option sTD sTD Option sTD Option Option Option Option Option Option sTD sTD sTD Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option sTD sTD sTD sTD sTD Option sTD Option Option Option Option Option Option Option sTD sTD sTD sTD Option Option Option Option Option Option Option Option CF CF CF CF CF CF CF CF CF CF CF CF Option CF CF CF CF CF CF CF CF CF sTD CF sTD CF sTD CF sTD CF sTD CF sTD sTD CF Option sTD Option sTD Option sTD Option sTD Option sTD Option sTD sTD sTD Option Option Option Option Option Option Option Option sTD Option Option Option Option Option Option sTD sTD sTD Option sTD Option sTD sTD sTD Option sTD Option Option Option Option Option Option sTD sTD sTD sTD sTD Option Option Option Option CF Option sTD Option sTD Option sTD CF CF Option (18) Option (18) accessories portfolio ORTFOLIO Air-cooled Chillers ewA/yQ009-011ACV3 ewA/yQ009-013ACw1 eUwAC-Fbzw1 Panels ekDssP ekDssP-s*** ekDDsP ekPwPRO ekPwPROM Serial Cards & Comm. Modules ekAC10C ekACPg ekAC200A ekAC200J ekACbAC ekACLOn ekACLOnP ekACRs232 ekACweb ekACbACMsTP ekACbACCeRT ekCM200J ekCMLOn ekCMbACMsTP ekCMbACIP LON Gateway ekLOnPg Other Systems & Accessories ekCLws ekCOn ekCOnUsb ekMODeM ekgsMOD ekRP1Hb ekRUPCJ ekRUPCk ekRUPCs ekPV2J ekPwPROexT ekgwweb ekgwMODeM ekbnPg ekbMsbnA ekbMsMbA ekRUMCA ekRUPC ekRUPg eHMC*AV1010 eHMC*AV1080 Gauges ekgAU5/8kA ekgAU10/12kA ekgAU16kA ekgAU20/24kA Soft starter ekss Buffer tank ekbT Waterpipe kit ekgn210 eUwA/y*-kbzw1 ewA/yQ-DAyn ewAD~D ewA(y)D~bz • • • • ewAD~C- ewAD • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • (5-8) • (10-12) • (16) • (20-24) • • • (080-210) • (ewAQ240-260DAyn & ewyQ230-250DAyn) ekgn260 * To install ekRUMCA => ekAC10C needs to be installed on the unit. • * ekAC10C allows direct connection to MODbUs bMs system Type: FwM-DT/DF, FwL-DT/DF, FwV-DT/DF 1 2 3 4 6 Description esRH03A6 esRH06A6 Additional single row heat exchanger esRH02A6 eeH06A6 electric heater eeH01A6 eeH02A6 eeH03A6 2-pipe 3-way valve e2MV03A6 e2MV06A6 4-pipe 3-way valve e4MV03A6 e4MV06A6 Fan stop thermostat yFsTA6 eAIDF03A6 eAIDF06A6 Air intake & discharge grille eAIDF02A6 supporting feet esFV06A6 esFVg3A6 esFVg6A6 supporting feet + grille esFVg2A6 eFA3A6 eFA6A6 Fresh air intake eFA2A6 eRPV3A6 eRPV6A6 Rear panel eRPV2A6 Control electromechanical eCFwMb6 electronic controller FweC1A, FweC2A, FweC3A Master slave option ePIMsb6 8 10 esRH10A6 eeH10A6 e2MV10A6 e4MV10A6 eAIDF10A6 esFV10A6 esFVg10A6 eFA10A6 eRPV10A6 10 fwV fwl fwM x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x * To install ekLOnPg & ekbnPg => ekACPg needs to be Type: Fwb-bT Description Additional heat exchanger 3-way valve add. h/e 3-way valve cooling h/e 2-way valve add. h/e 2-way valve cooling h/e electric Heater Fan stop thermostat Power interface Master slave interface 2-4 5-7 8-10 eAH04A6 eAH07A6 eAH10A6 e2MV310A6 e2MV307A6 Factory mounted e2MV207A6 e2MV210A6 Factory mounted Factory mounted yFsTA6 ePIb6 ePIMsb6 FweC1A Type: FwD-AT/ Description electric heater: electric heater: 2-pipe 3-way v 4-pipe 3-way v Vertical Drainp Horizontal Dra Fan stop therm Fresh air intake water-cooled Chillers D~Cz- ewwP-kbw1n ewLP-kbw1n eww(L)D~g- eww(L)D~I- • • • • • • • ewwD~bJ • • • • Centrifugals ewwQ~b- eww(L)D~J- ewwD~Fzxs • • • • • • • • DwsC & DwDC • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • (012-030) • (014-045) installed on the unit. /AF : small : big valve valve 4 (1) (2) 6 8 10 12 16 eDeH04A6 eDeHs06A6 eDeHs10A6 eDeHs12A6 eDeHs18A6 eDeH04A6 eDeHb06A6 eDeHb10A6 eDeHb12A6 eDeHb18A6 eD2MV04A6 eD2MV10A6 eD2MV12A6 eD2MV18A6 eD4MV04A6 eD4MV10A6 2xeD2MV12A6 2 x eD2MV18A6 pan eDDPV10A6 eDDPV18A6 ainpan eDDPH10A6 eDDPH18A6 mostat e 18 yFsTA6 eDMFA04A6 eDMFA06A6 eDMFA10A6 eDMFA12A6 eDMFA18A6 TyPe Description standard wired remote control simplified wired remote control simplified wired remote control wireless control for cooling only wireless control for heat pump Decoration Panel (RAL 9010 - grey sealings) 4-way blow Decoration Panel - standard (RAL 9010 - grey sealings) Round flow Decoration Panel - white11 (RAL 9010 - white sealings) Round flow sealing member of air discharge outlet Panel spacer FwT FwC-bT/bF FwF-bT/bF MeRCA sRC-COb sRC-HPb wRC-COb wRC-HPb - byCQ140Cw1 byCQ140Cw1w kDbHQ55C140 - byFQ60b kDbH44bA60 kDbQ44b60 Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on 85 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin quality Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability. 12 Environmental Awareness Daikin and the environment Air conditioning systems provide a significant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested a geat deal in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significant contribution to limiting the impact on the environment. Smart control brings comfort and reduces energy consumption Inverter technology used in the air cooled Mini Chiller (EWAQ-AC & EWYQ-AC), the heat pump inverter EWYD-BZ and the cooling only inverter EWAD-CZ, allows more precise control of the leaving water condition in function of the load. This leads to energy savings and high comfort levels, ensuring it is never too cool or too hot. This is a major advantage over standard fixed speed models, which use on/off cycling of the compressor, creating greater fluctuations in control conditions. This technology has now also been introduced into our water cooled range with the centrifugal inverter DWSC/DWDC series. 13 Inverter technology Water temperature Temperature remains stable Chiller without Inverter Shorter start-up Chiller Set temp. with Inverter Time Inverter technology offers improved levels of comfort: ›› Energy efficient: continuous matching of load requirement ›› Start-up time is reduced by 1/3 ›› Less frequent start/stop cycles ›› Reduced sound levels ›› High EER /COP values 14 Inverter technology for higher efficiency  Both inverter drive (ID) and variable frequency drive (VFD) are terms used to describe a piece of electrical hardware that is used to start, stop, and control the speed of an electric motor. When fitted to a single screw compressor or scroll compressor, an inverter allows it to continuously adapt the cooling capacity to the requirement of the building load by controlling the speed of the compressor motor. Principal benefits • Energy efficient: displacement power factor always > 0.95 Usually the power factor of a motor progressively worsens with the decrease of the power output. However thanks to the inverter, there is no need for additional power factor correction capacitors as the power factor is always > 0.95 and there are no power surges and so costs are constrained. • Quick start-up: start up time reduced by 1/3 The ability to vary the output power in direct relation to the cooling requirements of the system by allowing compressor boosts, gives the inverter chiller a reduced start-up-tooperating-capacity making it possible to achieving building comfort conditions in 1/3 less time than with conventional systems. • Less frequent start/stop cycles and low starting current The inverter technology ensures fewer start/stop cycles as well as ensuring that the start-up current is always lower than current absorbed in the maximum operating conditions (FLA). This generates obvious cost savings. • Seasonal quietness: reduced sound levels Low sound levels in partial load conditions are achieved by the variation of compressor frequency, thus ensuring the minimum sound levels at all times. Traditional systems using electric motors running at full speed even when unloaded waste electricity and with most building energy being consumed by HVAC operations, possible savings are important. With soaring energy prices and global warming concerns, our variable frequency drives for HVAC compressors, pumps, fans and motors are a major efficiency improvement as well as an energy saver and these combine to reduce costs. The full range of Daikin chillers now come with inverters already fitted or with an inverter alternative. 15 Reliable and Efficient Whatever the requirements of the customer, large systems requiring constant capacity or smaller systems for flexibility, Daikin always provides a reliable and efficient solution. THE Swing compressor: swing The Scroll compressor for controlled capacity: scroll Swing bush Ref. Gas The piston which the blade and the roller unified The Mini Chiller series EWAQ005-007ACV3 & EWYQ005-007ACV3 are equipped with a swing compressor. This innovative design by Daikin with fewer moving parts allows smoother more reliable operation with low vibration and low noise levels. The high efficiency motor reduces energy consumption resulting in energy cost savings. Being compact, the Daikin scroll compressor is used with R-407C and R-410A to provide constant reliability and high efficiency right throughout its service life. Designed for small and medium capacities, the scroll compressors are used with air cooled and water cooled chillers within the range of capacities between 9.1 and 281kW. Characteristics : ›› ›› ›› ›› ›› ›› Innovative frictionless centrifugal compressor : centrifugal Inverter speed control 2 stage centrifugal compressor Pressure and temperature sensors Permanent Magnet Direct Drive Motor Inlet Guide Vanes Motor and bearing control (the electronics) 16 Compact, simple yet robust design Absence of valves and oscillating connecting mechanisms providing maximum reliability Constant compression guaranteeing low energy consumption Increased compression efficiency thanks to the absence of volumetric re-expansion Low sound level Low starting current The innovative frictionless centrifugal compressor has an integrated VFD as well as magnetic bearings and delivers high levels of unit efficiency and reliability. The compressor’s one moving part – the rotor shaft and impellers – is powered by the permanent magnet direct drive motor and kept levitated by a digitally controlled magnetic bearing system. This reduction in moving parts significantly increases unit reliability and reduces maintenance costs. As the condensing temperature and/or cooling load reduces, the speed of rotation reduces and movable inlet guide vanes, activated by the step motor, redirect gas flow into the first stage impeller once the compressor has reached its minimum speed. This delivers increased efficiency and cost savings during part-load operation. standard anti -corr o si o n treatment As standard, condensers for air cooled chillers are given anti-corrosion treatment. This treatment significantly increases resistance to acid rain and saline corrosion. Depending on the capacities and models, treatments are of the following type: Example of acrylic treatment Acrylic treatment (Daikin ref PE) The aluminium fins are coated with an acrylic resin and a hydrophilic film. Epoxy Treatment The aluminium fins are black epoxy coated. The single screw STEPLESS compressor for high capacit y: The heart of the larger Daikin chillers is a semi hermetic ­single screw compressor, designed, tested and manufactured in ­Daikin’s own laboratories, in order to meet the highest ­capacity, performance and maintenance specifications. This compressor has been especially developed for operation with R-410A, R-134a or R-407C refrigerant, guaranteeing unequalled reliabi­ lity and many years of efficient operation. The bearing life is 100,000hrs with inspection and maintenance intervals every 40,000hrs. screw 11 2 10 Characteristics : 9 ›› 7 5 ›› ›› 12 8 3 4 1 6 ›› ›› 1. 2. 3. 4. 5. 6. Casing Slide valve Screw rotor Bearing Motor Gate rotor 7. 2nd stage oil separator 8. Demister (oil separator) 9. Refrigerant suction 10. Refrigerant discharge 11. Compressor terminal + CTP 12. Stepper Motor ›› ›› ›› 17 17 Optimal performance through stepless capacity control in function of the chilled water temperature. The unit capacity is infinitely variable from 30 - 100% on single circuit units and 15 - 100% on dual circuit units. Compact, simple yet robust construction. Using a main single screw and two gate rotors, axial and radial forces are balanced thanks to the symmetrical compression guaranteeing low bearing loads. Renowned for its low noise levels the double walled casing design and integrated oil separator, add to the attenuation effect. Gate rotors made of polymer material result in closer tolerances with main screw and reduced friction greatly improving compressor efficiency and lifetime. No oil pump necessary – lubrication based on differential pressure principle. Easy access to both compressor and safety devices Star delta starter with low starting current as standard Air Cooled In the chilled water market, chillers of the air cooled type are most frequently used. Out of its wide range of chillers in cooling only or heat pump version, with or without integrated hydronic components, Daikin always offers you a chiller fitting your application needs. TABLE OF CONTENTS EWAQ-ACV3 & EWAQ-ACW1 20 ewad-d-xr 48 EWYQ-ACV3 & EWYQ-ACW1 22 ewad-d-hs 50 euwac-fbzw1 24 ewad-bzss-sl 52 Euwa*-kbzw1 26 ewad-bzxs/xl/xr 54 Euwy*-kbzw1 28 ewYd-bzss 56 EWaQ-dayn 30 EWyd-bzsl 58 EWyQ-dayn 32 EWad-c-ss/sl 60 ewad-E-SS 34 ewad-c-sr 62 EWAD-E-SL 36 ewad-c-xs/xl 64 EWad-d-ss 38 ewad-c-xr 66 EWad-d-sl 40 ewad-c-ps/pl 68 EWad-d-sr 42 ewad-c-pr 70 EWad-d-sx 44 ewad-czxs/xl 72 EWAD-d-xs 46 ewad-czxr 74 18 Daikin has taken great care to match major chiller components and refrigerant combinations to a point where high efficiency ranges of technically advanced and closely optimised air and water cooled units are now widely available for use with R-410A, R-407C and R-134a refrigerants. swing scroll screw centrifugal A ir cooled chiller 7 3 2 5 4 5 Expansion vessel 1 t Chillers Evaporator Buffer Tank To fan coil units t t 1 1. 2. 3. 4. 6 Temperature sensor Filter Shut-off valve Pump 5 8 9 5. 6. 7. 8. 11 Pressure port Flow switch Air purge Pressure gauge 10 9. Balancing valve 10. Drain valve 11. Charging valve 12. Safety valve EWAQ-aC Air cooled mini chiller inverter Strengths ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-410A Inverter controlled swing compressor (size 005-007) - Precise temperature control Inverter controlled scroll compressor (size 009-011) Low operating sound level Easy ‘plug and play installation’ Wide operating range Integrated hydronics Digital controller s w i n g Options (factory mounted) ›› Evaporator heater tape OPTION KIT ›› Digital Input/Output PCP (size 009-013 only) CONTROL ›› Leaving water control Available Inputs ›› Voltage free contact: - ON/OFF Schedule timer: - ON/OFF - Silent operation 20 s c r o l l EWAQ005-007ACV3 + EWAQ009-011ACV3 / EWAQ009-013ACW1 Cooling only Capacity class Cooling capacity Power input EER ESEER Dimensions Weight Water heat exchanger Nom. Cooling Unit Unit Type Water volume Nominal water flow Air heat exchanger Type Nominal ESP unit Pump Hydraulic components Expansion vessel Fan Air flow rate Fan motor Speed Nom. HeightxWidthxDepth kW kW 005 5.2 1.89 2.75 3.75 mm kg EWAQ-ACV3 007 009 7.1 8.5 2.95 2.74 2.41 3.11 3.87 4.57 006 6.0 2.35 2.55 3.83 805x1,190x360 100 010 9.5 3.19 2.98 4.52 EWAQ-ACW1 011 11.0 3.82 2.88 4.63 013 13.2 5.10 2.59 4.52 25.8 31.5 37.8 56.4 49.1 10 - 40.9 011 009 11.0 9.0 3.82 2.96 2.88 3.04 4.46 4.68 1,435x1,418x382 180 Brazed plate Cooling Cooling Volume Cooling Nom. Cooling Nom. Steps Sound power level Cooling Nom. Sound pressure Cooling Nom. level Night quiet mode Cooling Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Water circuit Piping connections diameter Piping Piping Water heat exchanger inlet / outlet connections Water heat exchanger drain Power supply Phase / Frequency / Voltage l l/min kPa l m³/min rpm dBA dBA dBA °CDB °CDB kg inch inch 14.9 1.01 17.2 Tube type 45.1 6 - 49.4 20.4 24.4 27.2 31.5 38.3 58.0 54.6 10 100 49.1 Hi-XSS 96 97 780 8 62 48 63 50 Hermetically sealed swing compressor 5~20 10~43 1.7 1" MBSP Hose nipple 1/2" FBSP Hz / V 1~ / 50 / 230 21 64 51 45 Hermetically sealed scroll compressor 5~22 10~46 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 5/4" 3N~ / 50 / 400 66 52 46 EWYQ-AC Air cooled mini chiller inverter Strengths ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-410A Inverter controlled swing compressor (size 005-007) - Precise temperature control Inverter controlled scroll compressor (size 009-011) Low operating sound level Easy ‘plug and play’ installation Integrated hydronics Wide operating range Digital controller s w i n g OPTIONS (factory mounted) ›› Evaporator heater tape OPTION KIT ›› Digital Input/Output PCP (size 009-013 only) CONTROL ›› ›› Leaving water control Setpoint in heating & cooling AVAILABLE INPUTS ›› ›› Voltage free contact: - ON/OFF - Cooling/Heating changeover Schedule timer: - ON/OFF - Dual setpoint - Silent operation 22 s c r o l l EWYQ005-007ACV3 + EWYQ009-011ACV3/EWYQ009-013ACW1 Heating & Cooling Capacity class Cooling capacity Heating capacity Power input EER COP ESEER Dimensions Weight Nom. Nom. Cooling Heating Nom. Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Air heat exchanger Type Nominal ESP unit Cooling Pump Hydraulic components Expansion vessel Volume Fan Air flow rate Cooling Nom. Heating Nom. Fan motor Speed Cooling Nom. Heating Nom. Steps Sound power level Cooling Nom. Heating Nom. Sound pressure Cooling Nom. level Heating Nom. Night quiet Cooling mode Heating Compressor Type Operation range Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Charge Control Circuits Quantity Water circuit Piping connections diameter Piping Piping Water heat exchanger inlet / outlet connections Water heat exchanger drain Power supply Phase / Frequency / Voltage kW kW kW kW 005 5.2 5.65 1.89 1.97 2.75 2.87 mm kg kg EWYQ-ACV3 007 009 7.1 8.5 7.75 10.0 2.95 2.74 2.83 2.91 2.41 4.37 2.74 3.44 4.57 006 6.0 6.35 2.35 2.24 2.55 2.83 805x1,190x360 100 104 010 9.5 11.5 3.19 3.38 2.98 3.40 4.52 EWYQ-ACW1 011 11.0 12.5 3.82 3.70 2.88 3.38 4.63 013 13.2 14.0 5.10 4.19 2.59 3.34 4.52 25.8 31.5 31.5 35.8 37.8 40.1 56.4 49.1 40.9 011 009 11.0 9.0 13.0 11.0 3.82 2.96 3.86 3.23 2.88 3.04 3.37 3.41 4.46 4.68 1,435x1,418x382 180 - Brazed plate l l/min l/min kPa l m³/min m³/min rpm rpm dBA dBA dBA dBA dBA dBA °CDB °CDB °CDB °CDB kg inch inch 17.2 19.5 Tube type 45.1 6 - 14.9 17.5 49.4 1.01 20.4 23.5 24.4 28.7 27.2 33.0 31.5 37.3 38.3 58.0 54.6 49.1 Hi-XSS 10 96 100 90 97 780 760 8 62 63 64 - 66 64 48 48 50 49 Hermetically sealed swing compressor 5~20 25~50 10~43 -15~25 1.7 1" MBSP Hose nipple 1/2" FBSP Hz / V 1~ / 50 / 230 23 51 52 51 45 42 Hermetically sealed scroll compressor 5~22 25~50 10~46 -15~35 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 5/4" 3N~ / 50 / 400 46 43 EUWAC-FBZW1 Air cooled chiller with centrifugal fan Strengths ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-407C Daikin scroll compressor Electronic DDC controller Standard phase sequence controller Maximum external static pressure (ESP): 150Pa Pressure gauges Standard operation range down to -10°C Regulating switch Water inlet or outlet temperature control Input contacts/available outputs Input: on/off (per circuit), pump/flow switch Outputs: compressor operation, summary alarm, pump relay contact Compatible with hydraulic module µC² SE controller µC2 SE scroll Options (factory mounted) ›› Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) ›› ›› Address card for connection to BMS or remote user interface (EKAC10C) Remoted installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC10C needs to be installed on the unit Control ›› Water inlet temperature control Available inputs / outputs Input ›› ›› ON / OFF (per circuit) Pump / flow switch Output ›› ›› ›› Compressor operation Summary alarm Pump relay contact 24 EUWAC8FBZW1 Cooling only Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight Nom. Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Minimum water volume in the system evaporator Water flow rate Nom. Nominal water Cooling Heat exchanger pressure drop Model Type Quantity Air heat exchanger Type Fan Air flow rate Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Evaporator water drain Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/min kPa m³/min dBA 5 11.6 8 18.4 100-0 7.66 2.40 1,290x1,180x630 224 228 Brazed plate, one per circuit 153 53 5.2 2.23 1,345x856x630 164 166 101 33 9.67 2.46 1,395x1,330x630 261 266 212 68 26 42 48 AC70-24 AC70-34 1 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 109.8 66 Hermetically sealed scroll compressor -10 (OPZL) ~ 21 -10 ~ 43 R-407C Thermostatic expansion valve 1 3.9 FBSP 1" Field installation 3N~ / 50 / 400 AC70-40 70.2 63 °CDB °CDB kg 10 23.8 2.1 Hz / V 25 126 69 4.7 EUWA*-kBZW1 Air cooled chiller Strengths ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and and/or buffer tank Possibility for a 200l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWAN chiller without integrated hydraulic module ; - EUWAP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components) ; - EUWAB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µC² SE controller µC2 SE scroll Options (factory mounted) ›› ›› ›› Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) High ESP fans (50Pa) (OPHF) Pump size up (OPHP) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) ›› ›› ›› ›› ›› Refrigerant pressure gauges (EKGAU5/8/10/12/16/20/24KA) 200l buffer tank (EKBT, see EKBT page in this catalogue) Soft starter kit (EKSS) Address card for connection to BMS or remote user interface (EKAC10C) Remote installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC10C needs to be installed on the unit Control ›› Water inlet temperature control Available inputs / outputs Input ›› ›› Remote ON / OFF Pump contact Output ›› ›› ›› Compressor operation Summary alarm Pump relay contact Hydraulic CIRCUIT COMPONENTS Air purge Safety valve Pressure port Buffer tank Flow switch Water Pressure gauge Water flow adjusting valve Expansion vessel Pump Drain 26 EUWA*16KBZW1 EUWaP = EUWaN + EUWAN: ›› ›› ›› ›› ›› ›› Scroll compressor Main isolator switch Water flow switch Filter Condenser protection grille All year operation ›› ›› ›› ›› ›› ›› EUWaB = EUWaP + Pump Expansion vessel Adjusting valve Drain Water pressure gauge Pressure relief valve ›› Buffer tank Cooling only Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight Water heat exchanger Air heat exchanger Hydraulic components Fan group Fan group 2 Sound power level Compressor Operation range Refrigerant Refrigerant circuit Refrigerant circuit 2 Water circuit Power supply N5 Nom. Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Expansion vessel Volume Air flow rate Cooling Nom. Air flow rate Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Control Circuits Quantity Charge Charge Piping connections diameter Piping Phase / Frequency / Voltage kW % kW mm kg kg l l/min kPa l m³/min m³/min dBA P5 11.3 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 22.5 26.5 34.6 46.6 55.3 0-100 0-50-100 4.48 7.27 8.64 11.50 14.70 17.90 23.80 2.53 2.46 2.60 2.30 2.35 2.60 2.32 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734 150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526 152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592 Brazed plate 1.14 1.615 1.9 2.375 2.964 3.9 4.524 32 51 64 76 99 134 158 N8 24 12 160 (per 2 fans) 67 °CDB °CDB kg kg inch inch Hz / V B5 3.9 P8 19.7 B8 38 - 43 37 22 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 12 12 170 (per 2 fans) 170 (per 2 fans) 76 78 79 81 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-407C Thermostatic expansion valve 1 2 4.6 5.9 6.0 4.6 5.9 4.6 5.9 G 1"1/4 (male) 2" male 1-1/4" 3N~ / 50 / 400 27 12 6.0 6.0 EUWY*-kBZW1 Air cooled chiller Strengths ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and/or buffer tank Possibility for a 200l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWYN chiller without integrated hydraulic module; - EUWYP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components); - EUWYB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µC² SE controller µC2 SE scroll Options (factory mounted) ›› ›› ›› Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) High ESP fans (50Pa) (OPHF) Pump size up (OPHP) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) ›› ›› ›› ›› ›› Refrigerant pressure gauges (EKGAU5/8/10/12/16/20/24KA) 200l buffer tank (EKBT, see EKBT page in this catalogue) Soft starter kit (EKSS) Address card for connection to BMS or remote user interface (EKAC10C) Remote installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC10C needs to be installed on the unit Control ›› Water inlet temperature control Available inputs / outputs Input ›› ›› ›› Remote ON / OFF Pump contact Remote cool / heat selection ›› ›› ›› Compressor operation Summary alarm Pump relay contact Output 28 EUWY*16KBZW1 EUWYN: Standard equipment ›› Scroll compressor ›› Main isolator switch ›› Water flow switch ›› Filter ›› Condenser protection grille. ›› All year operation EUWYP = EUWYN + ›› ›› ›› ›› ›› ›› EUWYB = EUWYP + Pump Expansion vessel Adjusting valve Drain Water pressure gauge Pressure relief valve ›› Buffer tank Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity steps Power input EER COP Dimensions Weight Water heat exchanger Air heat exchanger Hydraulic components Fan group Fan group 2 Sound power level Compressor Operation range Refrigerant Refrigerant circuit Refrigerant circuit 2 Water circuit Power supply N5 Nom. Nom. Cooling Heating Nom. Nom. HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water Cooling flow Heating Nominal water Cooling Filter pressure drop Heating Filter Type Expansion vessel Volume Air flow rate Cooling Nom. Air flow rate Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Type Control Circuits Quantity Charge Charge Piping connections diameter Piping Phase / Frequency / Voltage kW kW % kW kW mm kg kg l l/min l/min kPa kPa l m³/min m³/min dBA °CDB °CDB °CDB °CDB kg kg inch inch Hz / V P5 9.1 11.9 B5 N8 P8 17.1 18.5 B8 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 21.0 25.0 34.2 40 50.0 24.0 27.0 37.0 46 54.0 0-100 0-50-100 3.77 7.38 8.49 11.3 14.8 16.2 22.6 4.56 7.01 8.98 10.7 14.10 17.3 21.4 2.41 2.32 2.47 2.21 2.3 2.5 2.2 2.61 2.64 2.67 2.52 2.62 2.66 2.52 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734 163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546 165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612 Brazed plate 1.140 1.615 1.900 2.375 2.964 3.900 4.524 26 49 60 72 98 115 143 34 53 69 77 106 132 155 10 25 24 33 12 19 17 29 31 38 14 16 22 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 12 12 12 12 160 (per 2 fans) 170 (per 2 fans) 170 (per 2 fans) 67 76 78 79 81 Hermetically sealed scroll compressor -10(OPZL) ~ 20 35 ~ 50 -15 ~ 43 -10 ~ 21 R-407C Thermostatic expansion valve 1 2 4.6 4.7 5.4 5.1 5.4 5.6 5.1 5.4 5.6 G 1"1/4 (male) 2" male 1-1/4" 2" 3N~ / 50 / 400 29 EWAQ-dayn Air cooled chiller, multiple scroll Strengths ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-410A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values Anti-corrosion treated aluminium coils Low operating sound level Easy ‘plug and play’ installation Fans protected against abnormal operation (4 - 8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via 2 independent refrigerant circuits (EWAQ130-260DAYN) Double circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface PCASO scroll Options (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Single pump contactor (OPSC) Twin pump contactor (OPTC) Single pump (OPSP) Twin pump (OPTP) (1 pump casing, dual motor) High ESP pump (OPHP) (single pump only) Buffer tank (OPBT) Inverter fans (OPIF) (Not available with option OPLN) Glycol 0°C / -10°C (OPZL) Evaporator heater tape (OP10) Option valves (discharge, liquid line and suction stop valve: OP12) A-meter / V-meter (OP57) Low Noise (OPLN) (=OPIF + compressor housing) Condenser protection grills (OPCG) Accessories (kit) ›› ›› ›› ›› Gateway for LON (EKLONPG) Gateway for BACNET (EKBNPG) Address card (EKACPG) Remote user interface (EKRUPG) 30 EWAQ130,150DAYN Cooling only Capacity class Cooling capacity Capacity steps Power input EER ESEER Dimensions Weight Nom. Cooling kW % Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Nominal water flow Cooling Nominal water Cooling Total pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Water heat exchanger inlet / outlet connections Water heat exchanger drain Power supply Phase / Frequency / Voltage kW mm kg kg l/min kPa m³/min rpm dBA 080 80 100 105 130 131 180 210 182 209 21/290-25-50-75-100 43/50/570-25-50-75-100 71/79-100 46.6 56.3 64.5 74.6 2.81 2.70 2.82 2.80 4.34 4.22 4.36 4.32 2,311x2,000x2,631 2,311x2,000x3,081 1,500 1,550 1,800 1,850 1,517 1,569 1,825 1,877 Brazed plate 377 436 522 599 0-50-100 26.4 36.2 3.03 2.90 4.12 4.00 2,311x2,000x2,566 1,350 1,400 1,365 1,415 229 301 59 58 52 49 52 53 Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 900 970 88 89 90 Scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-410A 19 25 29 28 Electronic expansion valve 2 3" OD 1/2"G 3~ / 50 / 400 780 880 86 °CDB °CDB kg 150 152 33 1 Hz / V 31 240 260 236 254 22/2840/50/560-25-50-75-100 72/78-100 82.8 94.0 2.85 2.70 4.20 4.00 2,311x2,000x4,850 3,150 3,250 3,189 3,292 677 728 51 47 1,600 900 91 39 3" EWyQ-dayn Air cooled chiller, multiple scroll STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-410A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values Anti-corrosion treated aluminium coils Low operating sound level Easy ‘plug and play’ installation Fans protected against abnormal operation (4 - 8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via 2 independent refrigerant circuits (EWYQ130-250DAYN) Double circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface PCASO scroll OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Single pump contactor (OPSC) Twin pump contactor (OPTC) Single pump (OPSP) Twin pump (OPTP) (1 pump casing, dual motor) High ESP pump (OPHP) (single pump only) Buffer tank (OPBT) Inverter fans (OPIF) (Not available with option OPLN) Glycol 0°C / -10°C (OPZL) Dual pressure relief valve (OP03) Evaporator heater tape (OP10) Option valves (discharge, liquid line and suction stop valve: OP12) A-meter / V-meter (OP57) Low Noise (OPLN) (=OPIF + compressor housing) Condenser protection grills (OPCG) ACCESSORIES (kit) ›› ›› ›› ›› Gateway for LON (EKLONPG) Gateway for BACNET (EKBNPG) Address card (EKACPG) Remote user interface (EKRUPG) 32 EWYQ130,150DAYN Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity steps Power input EER COP ESEER Dimensions Weight Water heat exchanger Air heat exchanger Fan Sound power level Compressor Operation range Refrigerant Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply Nom. Nom. Cooling Heating kW kW % Nom. Nom. HeightxWidthxDepth Unit Unit Operation weight Type Nominal water Cooling flow Heating Nominal water Cooling Total pressure drop Heating Total Type Air flow rate Nom. Speed Cooling Nom. Type Water side Cooling Min.~Max. Water side Heating Min.~Max. Air side Cooling Min.~Max. Air side Heating Min.~Max. Type Control Circuits Quantity Charge Charge Water heat exchanger inlet / outlet Water heat exchanger drain Phase / Frequency / Voltage kW kW mm kg kg l/min l/min kPa kPa 080 77 87.7 100 100 114 130 136 149 180 210 183 211 199 225.00 21/290-25-50-75-100 43/50/570-25-50-75-100 71/79-100 47.6 55.7 63.8 75.3 49.6 58.8 68.0 77.0 2.86 2.60 2.87 2.80 3.00 2.81 2.93 2.92 4.31 4.07 4.33 4.23 2,311x2,000x2,631 2,311x2,000x3,081 1,550 1,600 1,850 1,900 1,567 1,619 1,875 1,927 Brazed plate, one per unit 390 416 525 605 427 473 570 645 43 38 41 44 51 49 48 50 Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 900 970 88 89 90 Scroll compressor -10 (OPZL) ~ 25 25 ~ 50 -15 ~ 43 -10 ~ 21 R-410A Electronic expansion valve 2 22 32 22 32 3" OD 1/2"G 3~ / 50 / 400 0-50-100 26.5 36.2 30.0 38.1 2.91 2.76 2.92 2.99 4.00 3.81 2,311x2,000x2,566 1,400 1,450 1,415 1,465 221 251 287 327 36 47 m³/min rpm dBA 46 780 880 86 °CDB °CDB °CDB °CDB 1 kg kg 33 37 - Hz / V 33 150 145 165 230 250 231 252 258 281 22/2844/50/560-25-50-75-100 72/78-100 82.2 93.5 84.2 96.6 2.81 2.70 3.06 2.91 4.20 4.00 2,311x2,000x4,850 3,200 3,300 3,239 3,342 662 740 39 48 722 806 38 46 1,600 900 91 39 39 3" EWAD-E-SS Air cooled chiller, standard efficiency, standard sound STRENGTHS ›› ›› ›› ›› ›› ›› Wide capacity range: 10 sizes to cover a range from 101 to 413 kW One refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -18°C) Water supply down to -15°C MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› MicroTech III screw Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal overload relays Under/Over voltage control Energy meter Capacitors for power factor correction Current limit - display 20 mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) (Not available on sizes 100 and 120) Double pressure relief valve with diverter Compressor circuit breakers External tank with or without (500 and 1000 l) 34 EWAD100-210E-SS ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 100 101 120 121 Hz / V 160 163 180 183 210 214 260 256 310 307 360 360 410 413 Stepless 25 38.7 2.61 46.9 2.57 2.93 2,273x1,292x2,165 1,684 1,699 53.4 60.3 2.58 2.70 2.75 2.93 2,273x1,292x3,065 1,861 1,881 12 4.83 15 5.76 17 6.58 24 25 10,922 10,575 91.5 73.5 °CDB °CDB kg 140 138 18 21 20 7.77 24 68.5 71.7 2.67 2.98 2.81 3.02 2,273x1,292x3,965 2,086 2,116 Plate to plate 24 30 8.74 10.22 22 86.7 2.95 3.18 111 133 2.77 2.71 3.05 3.23 2,223x2,236x3,070 2,919 2,963 146 2.84 3.34 25 12.22 30 14.65 44 19.74 21 High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 920 92.3 93.0 94.2 73.7 73.9 75.1 75.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3" 3~ / 50 / 400 35 36 17.21 48 45 31,725 94.5 75.3 95.2 76.0 56 60 EWAD-E-SL Air cooled chiller, standard efficiency, low sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› Wide capacity range: 10 sizes to cover a range from 97.9 kW to 398 kW One refrigerant circuit with single screw compressor Low operating sound level Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -18°C) Water supply down to -15°C MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› MicroTech III screw Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal overload relays Under/Over voltage control Energy meter Capacitors for power factor correction Current limit - display 20 mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) (Not available on sizes 100 and 120) Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation External tank with or without (500 and 1000 l) 36 EWAD100-210E-SL ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 100 97.9 120 116 Hz / V 160 157 180 177 210 209 250 249 300 296 350 345 400 398 Stepless 25 38.8 47.9 2.52 2.42 3.01 2.97 2,273x1,292x2,165 1,784 1,799 53.0 60.6 2.53 2.60 2.85 3.00 2,273x1,292x3,065 1,961 1,981 12 4.68 17 6.40 15 5.54 23 8,372 8,144 89.0 71.0 °CDB °CDB kg 130 134 18 21 20 7.51 67.8 72.1 2.61 2.89 3.07 3.32 2,273x1,292x3,965 2,186 2,216 Plate to plate 24 30 8.47 9.97 21 20 84.5 2.95 3.55 110 134 2.69 2.58 3.41 3.34 2,223x2,236x3,070 3,029 3,073 150 2.65 3.45 25 11.90 30 14.15 36 16.50 44 19.01 46 45 44 42 High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 715 89.8 90.5 91.7 71.2 71.4 72.6 72.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3" 3~ / 50 / 400 37 24,433 92.0 72.8 92.7 73.5 56 60 EWAD-D-SS Air cooled chiller, standard efficiency, standard sound STRENGTHS ›› ›› ›› ›› ›› ›› Standard efficiency level Standard sound level configuration: condenser fan rotating at 920 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) MicroTech III Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation screw OPTIONS (factory mounted) 38 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD390D-SS Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 390 389 440 436 470 466 152 2.56 3.36 2,223x2,234x3,139 2,960 3,090 164 2.66 3.54 167 2.79 3.55 4,030 4,195 4,220 530 532 560 556 580 578 194 2.74 205 2.72 3.56 197 2.93 3.39 3.52 2,223x2,234x4,040 4,230 4,395 Single pass shell & tube 165 4,235 130 165 175 18.60 20.80 22.20 24.00 25.40 26.50 27.60 45.6 37.9 66.5 47.1 52.1 57.4 51.2 32,772 95.8 96.7 76.5 56 139.7mm Hz / V 3 / 50 / 400 39 42,300 98.7 78.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 70 76 82 60 160 High efficiency fin and tube type with integral subcooler 43,694 43,455 43,694 920 96 96.7 98.2 77.0 °CDB °CDB kg 510 502 Stepless 12.5 184 2.73 79.0 87 92 EWAD-D-SL Air cooled chiller, standard efficiency, low sound STRENGTHS ›› ›› ›› ›› ›› ›› Standard efficiency level Low sound level configuration: condenser fan rotating at 715/900 rpm, rubber antivibration under compressor, compressor sound enclosure Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) MicroTech III Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation screw OPTIONS (factory mounted) 40 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD400-530D-SL Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 180 184 200 198 81.4 79.7 2.26 2.48 3.00 3.12 2,355x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30 230 225 250 245 84.5 2.66 3.31 93.4 101 108 2.62 2.58 2.54 3.21 3.26 3.23 2,355x2,234x3,139 2,860 2,960 9.40 10.70 11.70 28.9 21.8 57.8 49.0 15,300 280 275 100 8.80 14,900 22,900 900 300 320 370 400 298 321 370 404 Stepless 12.5 119 123 133 169 2.50 2.60 2.78 2.39 3.20 3.24 3.41 3.65 2,223x2,234x3,139 2,960 4,029 3,090 4,194 Single pass shell & tube 130 165 42 48 50 170 195 2.73 3.77 4,234 165 160 17.70 19.30 21.00 22.80 24.10 25.40 53.9 58.9 59.5 55.2 67.4 47.5 62.1 54.0 48.4 43.4 High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428 94.7 33,489 32,572 97.2 715 94.2 95.7 96.2 77.5 74.5 76.0 76.5 84 86 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 54 58 66 70 76 139.7 3 / 50 / 400 41 170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,224 4,229 4,394 530 533 15.30 114.3 Hz/V 510 505 14.20 94.3 88.9 480 477 13.10 75.0 36 440 440 12.50 93.7 °CDB °CDB kg 260 261 82 EWAD-D-SR Air cooled chiller, standard efficiency, reduced sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› Standard efficiency level Reduced sound level configuration: condenser fan rotating at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure under compressor, compressor sound enclosure. Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation MicroTech III screw OPTIONS (factory mounted) 42 EWAD400-530D-SR ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 180 177 190 190 84.0 82.7 2.11 2.30 2.89 3.00 2,355x2,234x2,239 2,620 2,650 Plate to plate 25 30 220 219 240 238 85.2 2.57 3.34 94.7 103 111 2.51 2.44 2.38 3.21 3.23 3.16 2,355x2,234x3,139 2,890 3,100 9.10 10.40 11.30 26.9 20.1 55.1 46.6 15,300 270 265 280 310 370 400 278 312 366 404 Stepless 12.5 122 125 138 169 2.28 2.49 2.65 2.39 3.13 3.25 3.42 3.65 2,223x2,234x3,139 3,110 4,040 3,240 4,342 Single pass shell & tube 130 165 100 8.50 14,900 22,900 680 12.00 50.8 12.60 13.30 55.2 89.3 42 48 50 88.9 530 533 170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,240 4,542 195 2.73 3.77 165 160 19.30 21.00 22.80 24.10 25.40 52.7 65.1 47.5 62.1 54.0 48.4 43.4 89.7 170 33,489 32,572 92.2 715 90.7 92.2 92.7 72.5 71.0 72.5 73.0 84 86 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 54 58 66 70 2 76 139.7 3 / 50 / 400 43 510 505 17.40 114.3 Hz / V 480 477 14.90 70.0 36 440 440 High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428 88.7 °CDB °CDB kg 250 252 82 EWAD-D-SX Air cooled chiller, standard efficiency, extra low sound STRENGTHS ›› ›› ›› ›› ›› ›› Standard efficiency level Extra low sound level configuration: condenser fan rotating at 500 rpm, rubber antivibration under compressor, compressor and evaporator sound enclosure Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation MicroTech III screw OPTIONS (factory mounted) 44 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD230-410D-SX Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 210 203 230 231 250 253 79.9 2.54 3.39 2,420x2,234x3,139 3,110 3,200 85.2 2.71 3.63 93.5 2.70 3.52 3,475 90 115 9.70 11.00 12.10 44.7 33.8 38 12,900 270 271 300 310 299 309 Stepless 12.5 104 114 126 136 2.59 2.50 2.37 2.27 3.55 3.44 3.39 3.25 2,420x2,234x4,040 3,425 3,430 3,590 Single pass shell & tube 165 160 370 370 410 413 148 2.49 3.24 169 2.44 3.49 3,560 3,735 4,302 4,472 84.3 173 187 2.60 2.63 3.61 3.58 2,420x2,234x4,940 4,506 4,581 4,676 4,746 175 170 165 14.30 14.70 17.70 19.70 21.50 23.50 38.3 34.9 37.7 40.5 44.5 43.9 50 44.8 25,933 28,625 33,116 85.7 86.2 65.5 66.0 76 82 65.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 60 56 114.3 Hz / V 65 70 139.7 3 / 50 / 400 45 490 492 13.70 High efficiency fin and tube type with integral subcooler 17,200 26,495 500 84.7 17,900 450 451 12.90 °CDB °CDB kg 290 286 EWAD-D-XS Air cooled chiller, high efficiency, standard sound STRENGTHS ›› ›› ›› ›› ›› ›› High efficiency Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) MicroTech III Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation screw OPTIONS (factory mounted) 46 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD250D-XS Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 250 247 280 275 300 302 79.1 3.12 3.56 2,355x2,234x3,138 2,905 3,000 87.1 3.16 3.60 94.1 3.20 3.62 104 113 127 3.15 3.12 3.16 3.85 3.67 3.59 2,355x2,234x4,040 3,235 3,240 3,400 Single pass shell & tube 165 160 15.60 46.1 3,285 95 115 11.80 13.10 14.40 48.1 44.9 48.8 22,300 330 327 380 376 Stepless 12.5 120 3.14 3.58 400 401 470 469 520 524 150 3.12 3.84 2,223x2,234x4,040 3,510 3,780 166 3.15 4.00 16.70 17.90 19.10 22.40 30,600 96.8 25.00 27.40 29.70 50.8 57.6 63.5 47.4 62.9 56.2 37.9 77.5 58 66 76 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 73 76 47 255 54,616 920 99.2 86 100 168.3 3 / 50 / 400 620 622 181 194 3.18 3.20 4.01 3.88 2,223x2,234x4,940 4,670 4,685 4,940 79.0 114.3 Hz / V 580 575 270 High efficiency fin and tube type with integral subcooler 29,700 44,000 43,000 43,695 900 97.2 98.7 °CDB °CDB kg 350 351 EWAD-D-XR Air cooled chiller, high efficiency, reduced sound STRENGTHS ›› ›› ›› ›› ›› ›› High efficiency Reduced sound level configuration: condenser fan rotating at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -18°C) MicroTech III Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation screw OPTIONS (factory mounted) 48 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD270-390D-XR Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 240 243 270 272 300 296 320 322 80.6 3.01 3.63 2,355x2,234x3,138 3,005 3,100 87.0 3.12 3.70 95.1 3.11 3.69 106 115 127 3.05 2.99 3.10 3.82 3.71 3.82 2,355x2,234x4,040 3,335 3,340 3,500 Single pass shell & tube 165 160 15.40 44.7 3,385 95 115 11.60 13.00 14.10 46.7 44.0 47.5 370 370 Stepless 12.5 119 3.12 4.01 390 394 460 455 510 512 152 2.99 3.89 2,223x2,234x4,040 3,610 3,880 167 16.40 17.70 18.80 21.70 91.8 24.40 26.80 28.60 49.2 56.2 55.6 44.8 60.4 53.7 36.1 72.5 60 560 561 183 198 3.07 3.03 4.11 3.93 2,223x2,234x4,940 4,770 4,785 5,040 255 41,861 41,864 715 93.7 73.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 80 68 114.3 Hz/V 49 104 168.3 3 / 50 / 400 600 600 270 High efficiency fin and tube type with integral subcooler 12,500 33,488 680 92.2 93.2 °CDB °CDB kg 350 345 EWAD-D-HS Air cooled chiller, high ambient STRENGTHS ›› ›› ›› ›› ›› ›› High ambient Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Large operation range (ambient temperature down to -18°C) MicroTech III Standard available ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery 1 circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 20 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (1000 l) External tank (500 l) with cabinet External tank (1000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation screw OPTIONS (factory mounted) 50 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD340-450D-HS Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 200 195 210 208 77.2 75.5 2.52 2.76 3.11 3.26 2,223x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30 230 234 260 256 83.0 270 274 91.0 97.7 104 2.80 2.78 3.34 3.21 3.30 3.28 2,223x2,234x3,339 2,865 2,870 2,960 2.81 95 310 306 112 2.73 3.27 90 340 380 420 336 381 415 Stepless 12.5 120 127 141 2.80 3.00 2.94 3.25 3.57 3.61 2,223x2,234x4,040 3,185 3,277 3,300 3,447 Single pass shell & tube 115 450 448 480 478 150 2.98 162 2.95 510 514 550 547 175 182 2.94 3.00 3.68 3.66 3.71 2,223x2,234x4,940 3,942 4,356 4,361 4,112 4,526 170 165 590 587 191 3.07 3.79 4,366 160 9.30 9.90 11.10 12.20 13.10 13.80 14.60 16.00 18.20 19.80 21.40 22.80 24.50 26.10 28.00 31.5 23.7 46.1 52.1 53.7 59.3 64.4 58.3 69.9 45.8 52.5 58.0 50.9 55.7 52.6 23,900 22,800 High efficiency fin and tube type with integral subcooler 35,000 34,100 47,900 43,694 42,300 900 96.3 96.7 98.7 96.7 35,900 95.7 77.0 79.0 °CDB °CDB kg 290 289 36 42 44 55 88.9 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 56 58 66 70 114.3 Hz / V 90 97.7 99.2 99.7 77.5 79.0 79.5 95 100 139.7 3 / 50 / 400 51 77.0 54,616 920 EWAD-BZSS/SL Air cooled inverter chiller, standard efficiency, standard/low sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ESEER up to 4.70 All models are PED pressure vessel approved Inverter stepless single-screw compressor Optimised for use with R-134a Cooling range: 329-515kW 2 truly independent refrigerant circuits DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops The ability to vary the output power in direct relation to the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up Standard electronic expansion valve Partial and total heat recovery option available Power factor over 0.95 Standard operation range down to -10°C PCO2 screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Inverter compressor starter Evaporator victaulic kit Fan silent mode Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Hour run meter General fault contactor Main switch interlock Fan speed regulation OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery (1 circuit) Partial heat recovery Brine version Under/overvoltage control Energy meter Current limit / display 20mm evaporator insulation Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti-vibration mount Spring anti-vibration mount One centrifugal pump (low or high lifting) Two centrifugal pumps (low or high lifting) External tank with or without cabinet (500 or 1000l) Set point reset, demand limit and alarm Double pressure relief valve with diverter Accessories ›› ›› ›› ›› ›› ›› ›› ›› ›› Address card RS485 (EKAC200J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS232 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPV2J) 52 EWAD330,360BZ Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (SS) Weight (SL) Water heat exchanger Air heat exchanger Fan Sound power level (SS) Sound power level (SL) Sound pressure level (SS) Sound pressure level (SL) Compressor Operation range Refrigerant Piping connections Power supply Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase / Frequency / Voltage kW % kW mm kg kg kg kg l l/s kPa l/s rpm dBA dBA dBA dBA 330 329 360 358 120.0 136 2.74 2.63 4.59 4.60 2,355x2,234x4,381 4,190 4,440 4,340 4,590 271 15.72 17.10 264 60 61 420 423 Stepless 13.5 147 159 2.69 2.66 4.55 4.59 2,355x2,234x5,281 4,590 4,840 4,740 4,990 Single pass shell & tube 256 18.87 20.21 72 67 460 459 490 488 520 515 168 2.73 4.57 181 2.70 4.70 2,355x2,234x6,181 4,990 5,240 5,140 5,390 193 2.67 4.60 21.93 23.32 24.61 78 69 76 248 High efficiency fin and tube type with integral subcooler 40,833 700 103.2 97.3 83.0 77.0 Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3mm 3~ / 50 / 400 32,667 102.8 96.9 °CDB °CDB kg 400 395 73 Hz / V 53 49,000 103.6 98.2 83.5 77.5 118 121 EWAD-BZXS/XL/XR Air cooled inverter chiller, high efficiency, standard/low/reduced sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High seasonal efficiency (ESEER up to 5.01) All models are PED pressure vessel approved Inverter stepless single-screw compressor Optimised for use with R-134a Cooling range: 329-515kW 2 truly independent refrigerant circuits DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops The ability to vary the output power in direct relation to the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up Standard electronic expansion valve Partial and total heat recovery option available Power factor over 0.95 Standard operation range down to -10°C PCO2 screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double setpoint Fans circuit breakers Phase monitor Inverter compressor starter Evaporator victaulic kit Fan silent mode Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Hour run meter General fault contactor Main switch interlock Fan speed regulation OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery (1 circuit) Partial heat recovery Brine version Under/overvoltage control Energy meter Current limit - display 20mm evaporator insulation Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti-vibration mount Spring anti-vibration mount One centrifugal pump (low or high lifting) Two centrifugal pumps (low or high lifting) External tank with or without cabinet (500 or 1000l) Set point reset, demand limit and alarm Double pressure relief valve with diverter Accessories ›› ›› ›› ›› ›› ›› ›› ›› ›› Address card RS485 (EKAC200J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS232 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPV2J) 54 EWAD330,360BZ Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS) Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Weight (XL) Unit Operation weight Weight (XR) Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (XS) Cooling Nom. Sound pressure Cooling Nom. level (XS) Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Sound power level (XR) Cooling Nom. Sound pressure Cooling Nom. level (XR) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW mm kg kg kg kg kg kg l l/s kPa 330 329 360 358 118.0 135 2.79 2.65 4.79 4.82 2,355x2,234x4,381 4,190 4,440 4,340 4,590 4,390 4,640 271 15.72 17.10 264 60 61 l/s rpm dBA dBA 32,667 dBA dBA 96.9 dBA dBA 92.9 420 423 Stepless 13 145 157 2.72 2.69 4.78 4.84 2,355x2,234x5,281 4,590 4,840 4,740 4,990 4,790 5,040 Single pass shell & tube 256 18.87 20.21 72 67 460 459 490 488 520 515 165 2.78 4.81 178 2.74 5.01 2,355x2,234x6,181 4,990 5,240 5,140 5,390 5,190 5,440 190 2.71 4.84 21.93 23.32 24.61 78 69 76 248 High efficiency fin and tube type with integral subcooler 40,833 700 103.2 102.8 83.0 77.0 73.0 55 98.2 94.2 73.5 Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3 3~ / 50 / 400 Hz / V 103.6 77.5 93.3 73 49,000 83.5 97.3 °CDB °CDB kg 400 395 118 121 ewyd-bzss Air cooled heat pump inverter chiller, standard efficiency, standard sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-134a Cooling range: 254-583kW Heating range: 270-615kW EER range up to 2.83 Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial and total heat recovery option available PID microprocessor control Power factor up to 0.95 2-3 truly independent refrigerant circuits Standard operation range down to -12°C PCO2 screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double set point Fans thermal relays Phase monitor Inverter compressor starter Evaporator victaulic kit Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers General fault contactor Hour run meter OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Brine version Under/ overvoltage control Current limit - display 20 mm evaporator insulation Fan speed control device (phase cut on fan) Condenser coil guards Cu-cu condensing coils Cu-Cu-Sn condensing coils Alucoat condensing coils Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) Double pressure relief valve with diverter External tank with or without cabinet (500 or 1000 l) Fan silent mode Accessories ›› ›› ›› ›› ›› ›› ›› ›› ›› Address card RS485 (EKAC200J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS232 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPV2J) 56 EWYD250-290BZ Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water Cooling Heat exchanger pressure drop Heating Heat exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Heating Nom. Sound pressure level Cooling Nom. Heating Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW kW % kW kW mm kg kg l l/s l/s kPa kPa 250 254 270 270 273 297 290 292 324 90.3 100 109 90.4 99 107 2.81 2.74 2.69 2.98 2.99 3.03 4.05 4.04 4.01 2,335x2,254x3,547 3,410 3,455 3,500 3,550 3,595 3,640 320 324 333 138 13.03 14.18 13.94 15.49 37 42 48 53 42 49 58 55 100.5 100.5 82.1 82.1 94 410 413 443 440 436 463 460 457 475 510 505 530 161 164 2.83 2.90 4.31 178 176 2.83 3.02 100 Hz / V 57 520 522 558 580 583 615 186 184 2.81 3.04 215 205 2.71 3.00 4.05 9 5,015 5,255 4.13 2,335x2,254x6,583 5,495 5,735 5,724 5,964 5,953 240 21.83 22.68 24.11 25.33 24.92 26.65 218 27.87 29.39 229 58 53 57 46 51 61 50 53 65 60 57 65 52 57 66 55 60 71 High efficiency fin and tube type with integral subcooler 42,304 52,880 920 101.2 101.8 101.2 101.8 82.3 82.5 82.3 82.5 Semi-hermetic single screw compressor -8~15 -10~45 R-134a 118 121.0 124 148 177 2 139.7 3~ / 50 / 400 31,728 88 380 382 410 Stepless 13 124 134 142 152 163 124 132 141 155 165 2.74 2.73 2.68 2.72 2.68 2.80 2.87 2.90 2.85 2.81 4.01 4.02 3.94 4.03 4.01 2,335x2,254x4,381 2,335x2,254x5,281 3,870 3,940 4,010 4,390 4,010 4,068 4,138 4,518 Single pass shell & tube 133 128 15.46 16.21 17.42 18.25 19.72 20.81 15.89 16.66 18.11 19.57 21.15 22.14 °CDB °CDB kg 370 365 379 116 117 2.79 2.84 4.07 12.12 12.89 l/s rpm dBA dBA dBA dBA 340 339 349 63,456 103.6 103.6 83.7 83.7 183 3 219.1mm 186 Ewyd-Bzsl Air cooled heat pump inverter chiller standard efficiency, low sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Optimised for use with R-134a Cooling range: 248-567kW Heating range: 270-615kW EER range up to 2.87 Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Low operating sound level Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial and total heat recovery option available PID microprocessor control Power factor up to 0.95 2-3 truly independent refrigerant circuits Standard operation range down to -12°C PCO2 screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double set point Fans thermal relays Phase monitor Inverter compressor starter Evaporator victaulic kit Fan speed control device (phase cut on fan) Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers General fault contactor Main switch interlock Hour run meter OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Brine version Under/ overvoltage control Current limit - display 20 mm evaporator insulation Condenser coil guards Cu-cu condensing coils Cu-Cu-Sn condensing coils Alucoat fins Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) Double pressure relief valve with diverter External tank with or without cabinet (500 or 1000 l) Accessories ›› ›› ›› ›› ›› ›› ›› ›› ›› Address card RS485 (EKAC200J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS232 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPV2J) 58 EWYD250-290BZ Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water Cooling Heat exchanger pressure drop Heating Heat exchanger Air heat exchanger Type Fan Air flow rate Cooling Nom. Heating Nom. Fan motor Speed Cooling Nom. Heating Nom. Sound power level Cooling Nom. Heating Nom. Sound pressure Cooling Nom. level Heating Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW kW % kW kW mm kg kg l l/s l/s kPa kPa 250 248 270 270 266 297 290 291 324 88.5 98 109 90.4 99 107 2.80 2.70 2.66 2.98 2.99 3.03 4.18 4.16 4.11 2,335x2,254x3,547 3,750 3,795 3,840 3,888 3,933 3,978 320 316 333 138 12.70 14.18 13.89 15.49 36 40 48 51 42 49 58 55 94.0 94.9 75.6 76.5 94 400 403 443 430 425 463 450 448 475 156 164 2.87 2.90 4.31 5,525 5,765 100 Hz / V 59 490 493 530 510 510 558 570 567 615 9 174 183 214 176 184 205 2.83 2.79 2.65 3.02 3.04 3.00 4.29 4.23 4.10 2,335x2,254x6,583 6,005 6,245 6,234 6,474 6,463 240 21.39 22.68 23.56 25.33 24.34 26.65 218 27.11 29.39 229 55 50 55 44 48 59 48 51 62 60 57 65 52 57 66 55 60 71 High efficiency fin and tube type with integral subcooler 32,576 40,720 42,304 52,880 715 920 94.7 95.3 96.1 96.7 75.8 76.0 77.2 77.4 Semi-hermetic single screw compressor -8~15 -10~45 R-134a 118 121 124 148 177 2 139.7 3 ~/ 50 / 400 24,432 31,728 88 370 372 410 Stepless 13 122 132 142 149 161 124 132 141 155 165 2.72 2.68 2.62 2.71 2.64 2.80 2.87 2.90 2.85 2.81 4.18 4.16 4.13 4.19 4.14 2,335x2,254x4,381 2,335x2,254x5,281 4,210 4,280 4,350 4,730 4,343 4,408 4,478 4,858 Single pass shell & tube 133 128 15.12 15.83 16.98 17.77 19.28 20.30 15.89 16.66 18.11 19.57 21.15 22.14 °CDB °CDB kg 360 355 379 113 117 2.79 2.84 4.29 11.83 12.89 l/s l/s rpm rpm dBA dBA dBA dBA 330 331 349 48,864 63,456 97.0 98.4 77.2 78.6 183 3 219.1mm 186 EWAD-C-SS/SL Air cooled chiller, standard efficiency, standard/low sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wide capacity range: 16 sizes to cover a range from 647 to 1,922 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 46°C) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› MicroTech III screw Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay 60 EWAD-C- ACCESSORIES ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) ›› ›› BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (SS) Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Weight (SL) Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power Cooling Nom. level (SS) Sound pressure Cooling Nom. level (SS) Sound power Cooling Nom. level (SL) Sound pressure Cooling Nom. level (SL) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW 650 647 740 744 830 832 910 912 970 967 221 2.93 3.95 262 2.84 3.87 299 2.78 3.89 318 2.87 3.84 12.5 351 2.76 3.8 5,630 5,910 5,920 6,200 5,740 5,990 6,030 6,280 mm kg kg kg kg l l/s kPa l/s rpm dBA dBA dBA dBA 6,280 6,530 6,570 6,820 266 6,560 6,810 6,850 7,100 C13 H14 1,319 1,418 Stepless C14 1,419 C15 1,538 C16 1,622 C17 1,714 C18 1,802 C19 1,875 C20 1,922 251 30.9 35.56 39.74 43.6 46.21 50.85 55.04 62.9 67.7 67.78 73.5 77.51 81.89 86.00 89.50 91.70 73 59 52 61 68 63 72 54 58 47 59 65 73 36 39 40 53,444 High efficiency fin and tube type with integral subcooler 64,133 74,822 85,510 96,199 106,888 920 99.5 100.0 100.9 101.1 79.0 79.5 80.4 96.0 96.1 97.5 97.1 97.6 98.1 98.2 99.1 75.5 75.6 76.5 76.6 76.8 76.9 77 77.2 128 146 101.5 101.7 80.6 °CDB °CDB kg C12 1,152 7 402 441 474 500 551 580 618 665 682 714 2.86 2.99 2.84 2.79 2.8 2.77 2.71 2.75 2.69 3.84 4.08 4.07 3.88 3.9 3.87 3.78 3.79 3.81 3.77 2,540x2,285 2,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 2,540x2,285x11,985 x7,985 7,280 7,900 10,310 10,320 10,710 10,770 11,240 11,600 7,520 8,280 10,730 11,110 11,260 12,110 12,480 7,570 8,190 10,750 10,770 11,150 11,210 11,680 12,040 7,810 8,570 11,170 11,550 11,700 12,560 12,920 Single pass shell & tube 243 386 421 408 474 850 378 2.82 3.88 2,540x2,285 x7,085 7,010 7,250 7,300 7,540 2,540x2,285x6,185 5,760 6,010 6,050 6,300 C11 1,064 144 2 101.9 102.9 80.7 81.0 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 46 R-134a 162 178 196 260 219.1mm 3 / 50 / 400 61 103.2 128,266 103.3 103.5 103.7 81.2 81.5 81.9 99.9 101 77.9 78 275 305 81.1 99.5 77.3 77.4 261 3 168.3mm Hz / V 103.0 117,577 273mm EWad-c-sR Air cooled chiller, standard efficiency, reduced sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Reduced sound version Wide capacity range: 16 sizes to cover a range from 619 to 1,833 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 46°C) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Double pressure relief valve with diverter Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay 62 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD-C- Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW 620 619 720 715 790 789 880 876 920 922 223 2.77 4.08 272 2.62 3.96 315 2.51 3.98 331 2.65 3.99 12.5 369 2.5 4 5,920 6,200 6,030 6,280 mm kg kg l l/s kPa l/s rpm dBA dBA 2,540x2,285x6,185 6,050 6,300 6,750 6,820 266 251 C11 1,112 C12 H14 1,270 1,321 Stepless C13 1,367 C14 1,471 C15 1,556 C14 1,623 C17 1,714 C18 1,795 C19 1,833 7 395 417 457 495 517 576 603 647 702 718 757 2.59 2.67 2.78 2.67 2.64 2.55 2.58 2.51 2.44 2.50 2.42 3.96 4.12 4.00 3.9 3.87 3.9 3.83 3.79 3.82 3.77 2,540x2,285 2,540x2,285 2,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 2,540x2,285x11,985 x7,085 x7,985 6,850 7,300 7,570 8,190 10,750 10,770 11,150 11,210 11,680 12,040 7,100 7,540 7,810 8,570 11,170 11,550 11,700 12,560 12,920 Single pass shell & tube 243 386 421 408 474 850 29.57 34.15 37.71 41.83 44.05 48.75 53.11 60.67 63.11 65.32 70.28 74.32 77.57 81.80 85.60 87.50 67 55 47 57 62 58 68 50 54 44 54 60 66 33 36 37 41,006 91.5 92.0 71.0 71.5 High efficiency fin and tube type with integral subcooler 49,207 57,408 65,610 73,811 82,012 90,213 715 92.5 93.0 93.5 93.8 94 94.8 94.9 95.1 95.2 72 72.5 °CDB °CDB kg C10 1,020 128 144 2 72.6 72.7 72.9 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 46 R-134a 162 178 196 260 219.1mm 3 / 50 / 400 63 73.1 261 95.5 73.4 275 98,417 95.9 73.7 74 305 3 168.3mm Hz / V 73.0 90,216 273mm EWAD-C-XS/XL Air cooled chiller, high efficiency, standard/low sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High efficiency version Wide capacity range: 19 sizes to cover a range from 756 to 2,008 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 50°C) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay 64 EWAD-C- ACCESSORIES ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication ›› module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS) Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Weight (XL) Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Fan motor Speed Cooling Nom. Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW mm kg kg kg kg l l/s kPa 760 756 233 3.25 4.02 2,540x2,285 x6,185 5,990 6,240 6,280 6,520 251 36.1 80 830 830 890 990 C10 C11 C12 C13 H14 H15 C14 C15 C16 889 1,001 1,074 1,196 1,280 1,349 1,415 1,525 1,409 1,526 1,596 Stepless 12.5 253 278 307 338 364 400 411 444 475 437 474 504 3.28 3.2 3.26 3.18 3.29 3.2 3.29 3.19 3.21 3.23 3.22 3.17 4.11 4.02 4.11 4.05 4.14 4.02 4.28 4.31 4.35 4.23 4.19 4.17 2,540x2,285 2,540x2,285 2,540x2,285x9,785 2,540x2,285x11,985 x7,085 x7,985 10,560 11,310 11,570 6,340 6,360 7,190 7,470 8,220 8,240 8,900 11,040 12,170 12,430 6,580 6,600 7,600 7,870 8,610 8,630 9,890 11,000 11,760 12,010 6,630 6,650 7,480 7,760 8,510 8,530 9,190 11,490 12,610 12,870 6,870 6,890 7,880 8,160 8,900 8,920 10,180 Single pass shell & tube 243 403 386 979 491 850 39.67 42.49 47.82 51.32 57.13 61.18 64.45 67.50 72.86 67.34 72.9 76.24 56 64 69 45 51 71 77 80.7 80.3 80.4 96.8 97.4 98 98.2 98.8 98.9 76.3 76.5 76.9 77.1 76.7 76.8 °CDB °CDB kg 146 162 57 871 850 80.48 84.47 88.79 90.77 93.2 62 68 182 214 80.5 80.7 80.9 168.3 37 80.8 99.6 77.1 77.2 100 100.2 77.3 77.4 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 50 R-134a 225 291 297 312 2 kg mm Hz / V 64 39 219.1 3~ / 50 / 400 65 248 273 219.1 3 / 50 / 400 100.4 77 328 3 95.8 41 81 80.2 dBA dBA 100.5 77 7 561 590 615 642 672 3.15 3.09 3.04 2.99 4.13 4.12 4.03 4.01 2,540x2,285 2,540x2,285x14,685 x13,785 12,260 12,600 13,140 13,470 12,700 13,040 13,580 13,910 160,332 920 103.9 64,133 79.7 84 533 3.16 4.16 2,540x2,285 x12,885 11,900 12,760 12,350 13,200 High efficiency fin and tube type with integral subcooler 85,510 106,888 128,266 138,954 149,643 920 920 920 101.4 101.9 102.4 102.5 102.9 103.1 103.2 103.5 103.7 l/s rpm rpm dBA dBA 100.2 74,822 61 C17 C18 C19 C20 C21 C22 1,685 1,768 1,858 1,901 1,953 2,008 77.5 343 - 343 273 3~ / 50 / 400 3 / 50 / 400 43 EWad-c-xR Air cooled chiller, high efficiency, reduced sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High efficiency and reduced sound version Wide capacity range: 19 sizes to cover a range from 736 to 1,959 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 50°C) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay 66 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD-C- Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger Air heat exchanger Fan Sound power level Sound pressure level Compressor Operation range Refrigerant Refrigerant circuit Piping connections Power supply Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Charge Evaporator water inlet/outlet Phase / Frequency / Voltage kW % kW mm kg kg l l/s kPa l/s rpm dBA dBA 740 736 235 3.14 4.29 2,540x2,285 x6,185 6,280 6,520 810 811 870 866 254 281 3.2 3.08 4.36 4.23 2,540x2,285 x7,085 6,630 6,650 6,870 6,890 251 243 35.17 38.74 41.36 76 49,207 54 61 57,408 92 92.3 71.5 146 162 °CDB °CDB kg kg mm Hz / V 168.3 970 C10 C11 C12 C13 H14 H15 C14 C15 C16 C17 974 1,041 1,168 1,247 1,302 1,367 1,468 1,378 1,486 1,550 1,639 Stepless 12.5 309 343 365 404 415 454 491 438 479 513 541 3.15 3.03 3.2 3.08 3.14 3.01 2.99 3.15 3.1 3.03 4.34 4.24 4.38 4.25 4.33 4.38 4.43 4.34 4.26 4.2 2,540x2,285 2,540x2,285 2,540x2,285x9,785 2,540x2,285x11,985 x7,985 x12,885 11,000 11,760 12,010 12,350 7,480 7,760 8,510 8,530 9,190 11,490 12,610 12,870 13,200 7,880 8,160 8,900 8,920 10,180 Single pass shell & tube 403 386 979 491 850 46.54 49.76 55.78 59.56 62.21 65.20 70.00 65.85 70.98 74.07 78.32 58 65 43 49 67 73 79 74 54 59 65 C18 C19 C20 C21 C22 1,722 1,813 1,854 1,902 1,959 7 567 595 624 658 692 3.04 2.97 2.89 2.83 4.21 4.2 4.1 4.08 2,540x2,285 2,540x2,285x14,685 x13,785 12,700 13,040 13,580 13,910 871 850 82.3 86.61 88.5 90.7 61 35 37 93.5 39 High efficiency fin and tube type with integral subcooler 65,610 82,012 82,014 98,414 106,616 114,817 123,018 123,021 715 93.5 93.7 94.3 94.5 94.4 94.6 95.1 95.2 95.3 95.6 95.7 95.9 96.2 96.6 72.3 72.5 72.2 72.3 72.5 72.6 72.8 72.9 73 73.3 73.7 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 50 R-134a 182 214 225 291 297 312 328 343 2 3 248 343 219.1 273 219.1 273 3 / 50 / 400 67 41 EWAD-C-PS/PL Air cooled chiller, premium efficiency, standard/low sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Premium efficiency version Wide capacity range: 9 sizes to cover a range from 821 to 1,562 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 52°C) All models are PED pressure vessel approved Optimised for use with R-134a 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Fans speed regulation Double pressure relief valve with diverter Refrigerant recovery tank Evaporator right water connection Ground fault relay 68 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD-C- Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (PS) Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Weight (PL) Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (PS) Cooling Nom. Sound pressure Cooling Nom. level (PS) Sound power level (PL) Cooling Nom. Sound pressure Cooling Nom. level (PL) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW 820 821 890 890 980 975 225 3.64 4.44 249 3.58 4.5 274 mm l l/s kPa 7,530 8,130 7,820 8,420 4.41 7,660 8,700 7,950 8,990 599 301 3.56 2,540x2,285x8,885 kg kg kg kg C11 1,074 39.22 42.53 1,043 46.6 57 65 30 C12 1,158 Stepless 12.5 330 3.51 4.39 C13 1,279 363 3.52 4.53 4.44 2,540x2,285 2,540x2,285x9,785 x11,085 8,290 8,550 9,390 9,330 9,590 10,380 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 51.3 55.31 61.12 61 69 60 C14 1,390 C15 1,474 C16 1,562 396 3.51 4.31 424 3.48 4.33 453 3.45 4.32 2,540x2,285x11,985 9,730 10,720 10,720 11,010 66.41 979 70.30 74.50 73 81 89 High efficiency fin and tube type with integral subcooler 106,888 117,577 128,266 920 101.8 102.3 102.6 102.9 l/s rpm dBA dBA 96,199 79.5 80 80.5 80.4 80.5 80.8 81.1 dBA dBA 98.4 98.8 99.9 99.3 99.6 99.9 100.2 77.2 77.5 77.8 101 76.9 77 °CDB °CDB kg mm Hz / V 204 202 204 219.1 69 77.1 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 220 252 2 273 3 / 50 / 400 128,266 103.2 254 103.5 EWad-c-pR Air cooled chiller, premium efficiency, reduced sound STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Premium efficiency and reduced sound version Wide capacity range: 9 sizes to cover a range from 809 to 1,521 kW Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 52°C) All models are PED pressure vessel approved Optimised for use with R-134a 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay 70 ACCESSORIES ›› ›› ›› ›› ›› ›› ›› EWAD-C- Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. Unit HeightxWidthxDepth Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW 810 809 880 875 960 956 C10 1,053 219 3.7 4.63 244 3.58 4.59 272 3.51 4.54 299 3.52 4.59 mm 2,540x2,285x8,885 kg kg l l/s kPa 7,820 8,420 7,950 8,990 38.65 599 41.81 1,043 45.69 56 63 29 l/s rpm dBA dBA 73,811 92.7 71.2 mm 204 C13 1,251 364 3.44 4.53 2,540x2,285 2,540x2,285x9,785 x11,085 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 50.3 54.11 59.76 59 66 58 C14 1,359 C15 1,439 C16 1,521 396 3.43 4.51 425 3.39 4.50 457 3.33 4.45 2,540x2,285x11,985 10,720 11,010 64.95 979 68.7 72.6 70 77 84 High efficiency fin and tube type with integral subcooler 82,012 90,213 98,414 715 93.4 93.8 94.1 94.4 71.7 72.0 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 204 220 252 2 °CDB °CDB kg C11 1,132 Stepless 12.5 330 3.43 4.5 202 219.1 273 Hz / V 3 / 50 / 400 71 98,417 94.7 72.3 254 95 72.6 EWad-cZXS/XL Air cooled inverter chiller, high efficiency, standard/low sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› Wide capacity range Lower starting current and optimum power factor Wide range of operating conditions MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Single screw compressor Highest part load performances in its class MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double setpoint Compressor thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop screw OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Brine version Under / overvoltage control Ampere volt meter Current limit - display Evaporator flange kit Fan silent mode Fans speed control device Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure sied manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (3 different models) Two centrifugal pumps (4 different models) Double pressure relief valve with diverter Compressor circuit breakers Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay Accessories ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLO N) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 72 EWad670-C18cZXS/XL Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Cooling Nom. Method Minimum capacity Nom. Unit HeigtxWidthxDepth Unit (XS) Operation weight (XS) Unit (XL) Weight Operation weight (XL) Type Water volume Water heat exchanger Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Air heat exchanger Type Type Drive Diameter Fan Nominal air flow Quantity Model Speed Motor input Sound power level (XS) Cooling Nom. Sound pressure level (XS) Cooling Nom. Sound power level (XL) Cooling Nom. Sound pressure level (XL) Cooling Nom. Compressor Type Type Refrigerant circuit Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage Weight kW % kw mm kg kg kg kg l l/s kPa mm l/s No. rpm kW dBA dBA dBA dBA kg mm Hz/V 670 740 830 900 C10 C11 672 738 832 902 1037 1095 C12 C13 C14 C15 C16 C17 C18 1236 1308 1450 1545 1622 1709 1802 Stepless 20 20 20 20 20 20 20 20 20 20 13 13 13 245 235 266 305 339 375 400 442 488 531 558 588 611 2.74 3.14 3.13 2.96 3.06 2.92 3.09 2.96 2.97 2.91 2.91 2.90 2.95 5.07 5.13 5.20 5.22 5.24 5.03 4.93 4.74 5.02 5.17 5.51 5.33 5.19 2540x2285x6725 2540x2285x7625 2540x2285x8525 2540x2285x10325 2540x2285x11625 2540x2285x12525 2540x2285x13425 2540x2285x14325 5880 6000 6620 6870 7440 7440 8570 8970 9600 9940 11370 12190 12920 6140 6250 6860 7110 7880 7880 8960 9360 9980 10320 12220 13040 13790 6170 6280 6900 7150 7720 7720 8850 9250 9880 10220 11790 12610 13340 6430 6530 7140 7390 8160 8160 9240 9640 10260 10600 12640 13460 14210 Single Pass Shell&Tube 263 248 241 241 441 383 383 374 374 374 850 850 871 32.00 35.20 39.70 43.00 49.50 52.30 59.00 62.40 69.20 73.70 77.40 81.50 86.00 80 75 55 64 63 69 46 51 61 71 62 68 64 High efficiency fin and tube type with integral subcooler Direct propeller type DOL 800 800 800 800 800 800 800 800 800 800 800 800 800 54188 65025 75863 75863 86700 86700 108376 108376 119213 1300051 129454 140143 151129 10 12 14 14 16 16 20 20 22 24 24 26 28 900 900 900 900 900 900 900 900 900 900 900 900 900 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 102.1 102.2 102.5 102.5 102.9 102.9 103.5 103.5 104.1 104.1 105.8 106 106.2 81.0 81.0 81.1 81.1 81.1 81.1 81.2 81.2 81.2 81.2 82.8 82.9 82.9 98.6 99.2 99.5 99.5 99.9 99.9 100.5 100.5 101.1 101.1 102.8 103.0 103.2 77.5 78.0 78.1 78.1 78.1 78.1 78.2 78.2 78.2 78.2 79.8 79.9 79.9 Semi-hermetic single screw compressor inverter driven R-134a 141 161 178 178 200 200 235 235 275 320 327 343 361 2 168.3 219.1 273 273 273 3~/50/400 73 EWad-cZxr Air cooled inverter chiller, high efficiency, reduced sound STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› Wide capacity range Lower starting current and optimum power factor Wide range of operating conditions MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Single screw compressor Highest part load performances in its class MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Double setpoint Compressor thermal relays Phase monitor Evaporator victaulic kit 20mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop screw OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Brine version Under / overvoltage control Ampere volt meter Current limit - display Evaporator flange kit Fan silent mode Fans speed control device Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure sied manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (3 different models) Two centrifugal pumps (4 different models) Double pressure relief valve with diverter Compressor circuit breakers Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay Accessories ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLO N) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 74 EWad670-C18cZXS/XL Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Cooling Nom. Method Minimum capacity Nom. Unit HeigtxWidthxDepth Unit Operation weight Type Water heat Water volume exchanger - evapoNominal water flow Cooling rator Nominal water pressure drop Cooling Heat exchanger Air heat exchanger Type Type Drive Diameter Fan Nominal air flow Quantity Model Speed Motor input Sound power level (XL) Cooling Nom. Sound pressure level (XL) Cooling Nom. Compressor Type Type Refrigerant circuit Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage Weight kW % kw mm kg kg l l/s kPa mm l/s No. rpm kW dBA dBA kg mm Hz/V 640 700 790 850 980 C10 635 700 789 852 976 1,031 C11 C12 C13 C14 C15 C16 C17 1170 1,235 1,332 1,443 1,545 1,631 1,712 Stepless 20 20 20 20 20 20 20 20 20 20 20 20 20 260 242 271 314 347 388 408 455 524 589 580 610 631 2.44 2.89 2.91 2.71 2.81 2.65 2.86 2.71 2.55 2.45 2.66 2.67 2.71 5.52 5.71 5.76 5.76 5.79 5.49 5.41 5.05 5.45 5.60 5.51 5.33 5.19 25450x2285x6725 2540x2285x7625 2540x2285x8525 2540x2285x10325 2540x2285x11625 2540x2285x12525 2540x2285x13425 2540x2285x14325 6170 6470 7100 7360 7950 7950 9120 8530 10180 10530 12150 12990 13740 6430 6720 7340 7600 8390 8390 9500 9920 10550 10910 13000 13840 14610 Single Pass Shell & Tube 263 248 241 241 441 441 383 383 374 374 850 850 871 30.30 33.40 37.60 40.70 46.60 49.20 55.80 58.90 63.60 68.80 73.70 77.80 81.70 73 69 51 58 57 63 43 47 53 59 57 62 59 High efficiency fin and tube type with integral subcooler Direct propeller type DOL 800 800 800 800 800 800 800 800 800 800 800 800 800 41536 49843 58151 58151 66458 66458 83072 83072 83072 83072 99687 107994 116301 10 12 14 14 16 16 20 20 22 24 24 26 28 700 700 700 700 700 700 700 700 700 700 700 700 700 0.78 0.78 0.78 0.78 0.78 0.784 0.784 0.784 0.784 0.784 0.784 0.784 0.784 94.6 95.2 95.5 95.5 95.9 95.9 96.5 96.5 97.1 97.1 98.8 99.0 99.2 74.1 74.2 74.2 74.2 74.2 73.5 74.0 74.1 74.1 74.1 75.8 75.9 75.9 Semi-hermetic single screw compressor Inverter driven R-134a 141 161 178 178 200 200 235 235 275 320 327 343 361 2 168.3 219.1 273.0 273.0 273.0 3~/50/400 75 Condensing Unit The Daikin condensing units can be used in a wide variety of air conditioning, refrigeration and ventilation applications. TABLE OF CONTENTS erad-e-ss 78 erad-e-sl 80 76 PIPING DIAGRAM FOR COMFORT COOLING APPLICATION Chiller Air handling unit 1. Switchbox 2. Thermistor line ERAD-E-SS Air cooled condensing unit, standard efficiency, standard sound STRENGTHS ›› ›› ›› ›› ›› Wide capacity range (121 kW - 488 kW) Single refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -18°C) Water supply down to -15°C MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock screw OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Double pressure relief valve with diverter Automatic circuit breakers ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 78 ERAD170,200E-SS Cooling only Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range SST Min-Max Condenser Min-Max Refrigerant Type Charge Circuits Quantity Power supply Phase / Frequency / Voltage kW % kW mm kg kg l/s rpm dBA dBA 120 121 140 144 170 165 220 219 250 252 310 306 370 370 440 435 490 488 Stepless 25 41.8 51.0 2.90 2.83 2,273x1,292x2,165 1,584 1,617 10,922 10,575 91.5 57.4 65.2 73.7 76.6 92.8 122.0 147.2 160.8 2.87 3.00 2.97 3.28 3.30 3.04 2.96 3.03 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,741 1,936 2,679 1,781 1,981 2,756 High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 31,725 920 92.3 93.0 94.2 94.5 95.2 73.5 73.7 °C °C kg 200 196 17 20 22 Hz / V 79 73.9 75.1 75.0 Semi-hermetic single screw compressor -9~12 -18~48 R-134a 27 29 32 1 3~ / 50 / 400 75.3 45 76.0 54 58 ERAD-E-SL Air cooled condensing unit, standard efficiency, low sound STRENGTHS ›› ›› ›› ›› ›› ›› Low operating sound level Wide capacity range (116 kW - 462 kW) Single refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -18°C) Water supply down to -15°C MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock screw OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Double pressure relief valve with diverter Automatic circuit breakers ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 80 ERAD160,190E-SL Cooling only Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range SST Min-Max Condenser Min-Max Refrigerant Type Charge Circuits Quantity Power supply Phase / Frequency / Voltage kW % kW mm kg kg l/s rpm dBA dBA 120 116.0 140 137 160 159 210 209 240 243 300 295 350 352 410 409 460 462 Stepless 25 42.3 52.5 2.74 2.61 2,273x1,292x2,165 1,684 1,717 8,372 8,144 89.0 57.6 66.3 73.9 78.2 91.5 122 150 167 2.75 2.82 2.83 3.11 3.23 2.88 2.73 2.76 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,841 2,036 2,789 1,881 2,081 2,886 High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 24,433 715 89.8 90.5 91.7 92.0 92.7 71.0 71.2 °C °C kg 190 187 17 20 22 Hz / V 81 71.4 72.6 72.5 Semi-hermetic single screw compressor -9~12 -18~48 R-134a 27 29 32 1 3~ / 50 / 400 72.8 45 73.5 54 58 Water Cooled Daikin offers you compact water cooled chiller units which require only very limited space in a machine room. Used for commercial or industrial applications, these chillers generate cold and hot water, which can be used for chilling, heating, or even both at the same time. TABLE OF CONTENTS EWwp-kbw1n 84 ewwd-J-SS 86 ewwd-g-ss 88 ewwd-g-xs 90 ewwd-i-ss 92 ewwd-i-xs 94 ewwd-bjynn 96 ewwQ-b-ss 98 ewwQ-b-xs 100 EWWD-FZXS 102 DWSC / DWDC 104 82 1. Balancing valve 2. Pressure gauge 3. Temperature sensor 4. Drain valve 5. Shut-off valve 6. Fill valve 7. Filter 8. Drain 9. Safety valve 10. Pressure port 11. Pump 12. Flow switch 13. Pressure regulating valve 14. Bypass valve P I P I N G D I A G R A M FO R C OMFO R T C OOL I N G A PPL I C AT I O N Expansion vessel To fan coil units Evaporator Buffertank Condenser Chillers Buffer tank Expansion vessel To fan coil units EwWp-kBW1N Water cooled chiller STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Standard integrated: main switch, water filter, flow switch, air purge, pressure ports Daikin scroll compressor Optimised for use with R-407C Electronic DDC controller Low operating sound level Low energy consumption Extension possible up to 72HP Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Remote cooling or heating selection Water/water heat pump, with water reversibility Compatible with hydraulic module µC2 SE scroll µC² SE controller pCO3 controller for assembly of 2 or 3 modules For single module units ›› ›› Standard main isolator switch Basic hydraulic components for KA-series included with the unit as a kit: flow switch, air purge, filter + shut-off valves for both condenser and evaporator OPTIONS (factory mounted) ›› Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) ACCESSORIES (kit) ›› ›› ›› ›› Compressor soundproof material (-3dBA) Hydraulic module (see page EHMC-page in this catalogue) BMS gateway (MODBUS/JBUS / BACNET protocol) Remote user interface CONTROL ›› ›› ›› Microprocessor control Water inlet temperature control Cold water or hot water regulation AVAILABLE INPUTS / OUTPUTS Input ›› ›› ›› Remote ON / OFF Pump contact Cool/heat selection ›› ›› ›› Compressor operation Summary alarm Pump relay contact Output 84 EWWP014-035KBW1N EWWP090-130KBW1N EWWP145-195KBW1N Heating only & Cooling only Capacity class Cooling capacity Nom. Heating capacity Nom. Capacity steps number Power input Cooling Nom. EER HeightxWidthxDepth Dimensions Unit Weight Unit Operation weight Water heat Type exchanger Minimum water volume in the system evaporator Water flow rate Min. Nom. Max. Water heat Type exchanger Water flow rate Min. condenser Nom. Max. Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Evaporator water drain Condenser water inlet/outlet Condenser water drain Power supply Phase / Frequency / Voltage kW kW kW mm kg kg 014 13.0 16.6 022 21.5 27.3 028 28.0 35.4 035 32.5 41.2 1 5.79 7.48 8.75 3.71 3.74 3.71 600x600x600 118 155 165 172 3.61 3.60 l l/min l/min l/min 62 19 37 75 103 31 62 123 134 40 80 161 155 47 93 186 l/min l/min l/min dBA 24 48 95 39 78 157 64 51 102 203 59 118 237 71 °CDB °CDB kg 1.2 1 2 2.5 FBSP 25mm FBSP 25mm Hz / V 3.1 045 43.0 54.8 055 065 56.0 65.0 71.4 82.7 2 11.80 15.50 17.60 3.64 3.61 3.69 600x600x1,200 300 320 334 110 120 130 112 121 130 143 154 165 4 23.6 27.3 31.0 33.1 35.2 3.64 3.63 3.61 3.66 3.69 1,200x600x1,200 600 620 640 654 668 Brazed plate 205 268 311 205 268 311 62 80 93 123 142 161 173 186 123 161 186 247 284 321 347 373 247 321 373 493 568 642 694 745 Brazed plate 79 102 118 157 181 205 221 237 157 205 237 314 362 410 442 474 314 410 474 629 724 819 883 948 67 74 71 75 77 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 20 ~ 55 R-407C Thermostatic expansion valve 2 4 4.6 5.6 9.2 10.2 11.2 FBSP 40mm 2 x 2 x FBSP 38mm Field installation FBSP 40mm 2 x 2 x FBSP 38mm Field installation 3N~ / 50 / 400 85 090 86.0 110 100 99.0 126 145 142 181 155 155 198 39.1 3.63 42.8 3.62 920 165 168 214 175 177 226 185 186 237 195 195 248 6 46.5 48.6 50.7 52.8 3.61 3.64 3.67 3.69 1,800x600x1,200 940 960 974 988 1.002 205 204 222 407 444 814 889 241 482 963 268 311 254 267 280 507 533 559 1,015 1,066 1,118 260 283 307 323 339 355 519 567 614 647 679 711 1,038 1,133 1,229 1,293 1,357 1,422 73 76 78 79 6 13.8 14.8 15.8 3 x 2 x FBSP 38mm 3 x 2 x FBSP 38mm 16.8 EwWd-J-SS Water cooled chiller STRENGTHS ›› ›› ›› Compact design to allow easy indoor installation or retrofit operations High efficiency at full and partial load MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III STANDARD ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit 20 mm evaporator insulation Condenser victaulic kit Condenser Water Side Design 16 bar Condenser 2 passes (dt 4-8 °C) Evaporator flow switch Electronic expansion device Discharge line shut off valve Suction line shut off valve High pressure side manometers Hour run meter General fault contactor Main switch interlock Emergency stop screw Options ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit display Condenser double flanges kit 20mm condenser insulation Water pressure differential switch on evaporator Low pressure side manometers Fork-lift kit Rubber anti vibration mount Sound proof system Set-point reset, demand limit and alarm from external device Double pressure relief valve with diverter Automatic circuit breakers Accessories ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communciation module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 86 EWWD-J-SS Cooling only Capacity class Cooling capacity Nom. Heating capacity Nom. Capacity control Method Minimum capacity Power input Cooling Nom. Heating Nom. EER COP ESEER Dimensions Unit HeigtxWidthxDepth Weight Unit Operation weight Water Type heat exchanger - Water volume evaporator Nominal water Cooling Heat pressure drop exchanger Water Type heat exchanger - Water flow rate Nom. condensor Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Refrigerant Type Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage kW kW % kw kw mm kg kg l kPa 120 120 142 140 146 172 27.3 32.9 4.40 4.32 5.01 33.3 40.1 4.38 4.29 4.67 1,777 1,211 1,233 1,276 14 18 14 17 20 26 15 13 40 38 36 28 8.57 150 155 188 180 178 216 210 208 249 250 256 305 25 44.2 49.3 58.7 53.5 59.57 71.68 4.03 4.22 4.37 4.04 4.18 4.26 4.66 4.75 5.20 1,020x2,684x913 1,334 1,366 1,416 1,600 1,378 1,415 1,473 1,663 38.5 46.4 4.03 4.05 4.67 l/s kPa 7.04 9.25 10.62 13.30 20 12 11 11 11 kPa dBA 71.4 88.6 71.4 88.6 71.4 88.6 71.4 88.6 71.4 88.6 15.06 16 280 285 340 68.3 80.75 4.18 4.21 4.46 310 330 310 334 377 405 Stepless 77 92.88 4.03 4.06 4.80 82.7 99.9 4.04 4.05 4.84 360 357 432 88.4 107 4.04 4.04 5.00 1,607 2,668 2,700 2,732 1,675 2,755 2,792 2,830 Brazed plate, one per circuit 26 29 31 33 33 40 40 38 Double pass shell and tube 16.89 18.49 19.91 28.28 26 11 11 11 380 386 466 450 464 554 500 513 610 12.5 98.6 108 117 119 131 143 4.22 4.30 4.38 4.19 4.22 4.26 5.17 5.27 5.37 2,000x2,684x913 2,782 2,832 3,016 3,200 2,888 2,946 3,136 3,327 98.6 113 3.91 4.12 4.79 530 541 645 560 570 681 127 152 4.26 4.23 5.25 137 162 4.16 4.22 4.81 3,207 3,338 3,215 3,350 37 41 46 52 52 52 38 36 36 28 28 33 23.15 24.59 27.33 30.10 31.92 33.78 11 70.0 70.0 74.4 74.4 74.4 74.4 87.2 87.2 92.4 92.4 92.4 92.4 Semi-hermetic single screw compressor R-134a 1 400 416 499 11 11 16 16 26 74.4 92.4 73.8 91.8 73.0 91.0 73.0 91.0 73.0 91.0 2 76.2mm 2" 1/2 3 / 50 / 400 Hz / V 87 4" EWWD-G-SS Water cooled chiller, standard efficiency STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a EER range up to 4 1-2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Condenser water side design 16 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Evaporator flow switch Condenser flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 88 EWWD260G-SS Heating only & Cooling only Indoor units Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Total pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage kW kW 170 166 204 210 201 247 260 253 310 300 280 343 320 334 410 380 372 456 420 403 494 460 448 552 500 494 610 600 556 674 129 161 3.83 3.79 5.1 150 177 3.70 3.81 4.93 Stepless % kW kW mm kg kg l kPa l/s kPa 25 42.2 52.7 3.93 3.87 5.00 50.6 64.9 75.3 63.5 80.8 89.2 3.97 3.90 3.72 3.89 3.84 5.04 4.95 4.72 1,860x920x3,435 1,410 1,503 1,480 1,650 1,393 1,470 60 56 48 69 123 43 53 9.95 12.02 15.19 16.98 39 41 63 77 dBA dBA 93 117 4.00 3.91 5.33 2,687 2,697 2,840 2,850 Single pass shell and tube 118 113 64 63 2,762 2,970 173 72 Single pass shell and tube 19.99 22.22 40 12.5 101 115 127 144 3.97 3.89 3.89 3.84 5.29 5.19 1,880x860x4,305 2,702 2,757 2,860 168 54 24.08 41 87.7 68 26.90 29.77 33.73 57 60 75 90.2 69.7 71.7 °CDB °CDB kg 84.3 106 3.96 3.88 5.28 50 55 Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 50 Electronic expansion valve 1 55 110 2 88.9mm 114.3mm 5" 3 / 50 / 400 Hz / V 89 139.7mm EwWd-G-XS Water cooled chiller, high efficiency STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High efficiency All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a EER range up to 4.73 1-2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Condenser water side design 16 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Evaporator flow switch Condenser flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 90 EWWD650G-XS Heating only & Cooling only Indoor units Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Total pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage kW kW 190 186 220 230 223 264 280 277 326 320 307 354 380 366 434 400 408 482 460 444 524 87.2 110 4.68 95.1 120 4.67 500 496 585 550 541 638 650 604 712 115 144 4.72 4.43 6.30 137 162 4.39 4.40 5.85 Stepless % kW kW mm kg kg l kPa l/s kPa dBA dBA 25 39.6 50.1 4.70 4.38 5.97 1,650 1,800 125 12.5 48.1 59.4 60.6 74.5 4.64 4.66 4.35 4.38 5.9 5.92 1,860x920x3,435 1,665 1,680 1,810 1,820 120 25 110 35 44 10.78 12.95 16.07 18.08 17 20 25 28 79.2 99.9 4.62 4.34 6.15 105 132 4.73 4.38 4.42 6.24 6.23 6.31 1,880x860x4,305 2,800 2,945 2,955 2,975 3,020 3,280 3,290 3,315 Single pass shell and tube 170 285 30 24 Single pass shell and tube 21.27 23.66 2,990 3,340 280 28 39 46 57 25.76 28.71 31.34 35.40 16 15 19 17 88.2 90.9 69.7 71.7 Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 105 Electronic expansion valve °CDB °CDB kg 71.4 83.7 4.30 4.23 5.46 55 1 114.3mm 2 139.7mm 5" 3 / 50 / 400 Hz / V 91 100 168.3mm EwWd-I-SS Water cooled chiller, standard efficiency STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a Cooling range: 333–1,510kW EER range: 4.28 to 4.66 1-2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y - d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Condenser water side design 10 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Condenser 1 pass (dt 4-8 °C) MicroTech III screw OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit Evaporator water side design pressure 25 bar 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Condenser 2 passes (dt 9-15°C) Water pressure differential switch on condenser Water pressure differential switch on evaporator Evaporator flow switch Condenser flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 92 EWWD-I-SS Heating only & Cooling only Indoor units Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Heat exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage kW kW % kW kW mm kg kg l kPa l/s kPa dBA dBA 340 333 388.4 400 394 460 460 460 538 550 538 630 650 640 757 700 705 832 25 71.5 85.8 101 120 141 156 87.4 104 122 143 174 191 4.66 4.59 4.56 4.47 4.53 4.52 4.44 4.42 4.41 4.35 4.36 5.06 4.96 4.93 4.86 5.54 5.75 1,821x1,430x3,398 2,150 2,160 2,179 2,224 3,909 3,927 2,380 2,396 2,410 2,457 4,217 4,228 193 37 50 183 172 271 263 54 62 55 44 900 950 C10 C12 C13 C14 C15 C16 C17 910 986 1,027 1,155 1,204 1,274 1,346 1,401 1,455 1,072 1,161 1,217 1,363 1,427 1,507 1,227 1,661 1,730 Stepless 12.5 8.3 171 186 200 218 237 254 268 282 298 317 335 208 225 243 262 282 309 326 344 363 383 401 4.57 4.55 4.51 4.33 4.54 4.50 4.51 4.43 4.35 4.42 4.41 4.43 4.32 4.41 4.38 3.38 4.34 4.31 5.56 5.7 5.47 5.61 5.36 5.51 5.56 5.54 5.55 5.45 2,113x1,350x4,361 2,323x2,135x4,426 3,945 3,971 3,996 4,080 4,092 6,079 6,097 6,136 6,174 6,192 6,210 4,243 4,262 4,288 4,369 4,386 6,628 6,646 6,670 6,699 6,717 6,735 Single pass shell and tube 256 248 241 233 472 504 489 472 850 844 993 58 53 66 51 62 56 47 58 62 66 C18 1,510 1,790 353 420 4.28 4.26 5.27 6,228 6,761 71 Single pass shell and tube 19.33 22.92 26.80 31.44 37.31 41.14 45.53 49.21 53.03 57.52 60.39 67.32 70.33 74.34 78.55 82.08 85.52 89.01 26 28 93.7 96.6 30 96.7 26 96.9 25 97.3 97.8 28 98.9 99.8 100.4 100.8 101.2 103.0 75.2 76.2 78.2 77.8 78.2 78.7 79.8 80.7 80.4 80.8 81.2 83.0 Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve 2 104 100 156 155 154 °CDB °CDB 1 kg 800 782 919 54 52 51 50 108 106 168.3mm 26 23 5" 3 / 50 / 400 Hz / V 93 24 25 24 23 3 153 152 219.1mm 151 150 EwWd-I-XS Water cooled chiller, high efficiency STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High efficiency All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a Cooling range: 362–1,134kW EER range: 4.73 to 5.10 1 or 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye delta starter (y - d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Condenser water side design 10 bar Condenser 2 passes (dt 4-8 °C) Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Evaporator 1pass screw OPTIONS (factory mounted) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Soft starter Heat pump version Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit Evaporator water side design pressure 25 bar 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Condenser 4 passes Water pressure differential switch on condenser Water pressure differential switch on evaporator Evaporator flow switch Condenser flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 94 EWWD-I-XS Heating only & Cooling only Indoor units Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Heat exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Water flow Nom. rate 2 Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage kW kW % kW kW mm kg kg l kPa l/s l/min kPa dBA dBA 360 362 410.9 71 85.9 5.10 4.78 5.34 2,594 2,998 440 433 493 600 573 660 25 85.4 100 103 121 5.07 5.06 4.79 4.77 5.27 5.22 1,883x1,430x4,081 2,667 2,704 3,078 3,116 326 317 64 48 20.69 500 506 577 308 54 24.77 28.95 33.16 - 800 795 908 Stepless 156 189 5.10 4.80 6.31 48 48 47 96.6 51 96.7 75.20 76.2 78.2 950 933 1,069 C10 976 1,126 170 206 5.08 4.81 6.01 47 Single pass shell and tube 20.58 20.44 24.75 20.58 93.7 850 866 990 12.5 185 199 223 240 5.05 4.9 4.79 4.69 6.14 5.9 2,245x1,350x4,769 4,964 4,997 5,049 5,073 5,097 5,582 5,615 5,671 5,695 5,729 Single pass shell and tube 539 528 141 172 5.09 4.78 6.13 68 C11 1,038 1,203 C12 1,134 1,313 219 263 240 285 4.73 4.57 6.05 504 50 72 46 52 23.31 28.07 27.10 32.82 28 28.07 33 32.82 24.75 96.9 97.3 97.8 98.9 99.8 77.8 78.2 78.7 79.8 80.7 2 172 219.1mm 170 48 47 50 65 Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve 90 1 87 168.3mm 85 180 177 5" 3 / 50 / 400 Hz / V 95 174 4.61 5.67 5,132 5,741 24.98 66 °CDB °CDB kg 121 143 4.75 4.62 5.11 750 720 823 EwWd-bjynn Water cooled chiller STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› Cooling range: 369–1,050kW Super high efficiency: EER up to 5.8 ; A class energy label Very high EER values at part loads condition (ESEER up to 7.4) 1 and 2 stepless single-screw compressors Optimised for use with R-134a Flooded evaporator Expansion valve with liquid level control All models are PED pressure vessel approved STANDARD AVAILABLE ›› ›› ›› Digital controller screw Main switch Gauges Electronic expansion valve OPTIONS (factory mounted) ›› ›› ›› ›› ›› Glycol application Suction stop valve A / V meter Soft starter Cu / Ni heat exchanger ACCESSORIES ›› ›› ›› ›› ›› ›› Communication cards (EKAC200J – EKACBAC – EKACLON) Remote user interface (EKRUPCK) Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) Daikin serial sequencing panel (EKDSSP) Modem (EKMODEM – EKGSMOD) Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB) 96 EWWDC11BJYNN Cooling only Capacity class Cooling capacity Capacity steps Power input EER ESEER Dimensions Weight Nom. Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Minimum water volume in the system evaporator Water flow rate Min. Nom. Max. Nominal water Cooling Heat exchanger pressure drop Minimum water volume in the system Water heat exchanger Water flow rate Min. condenser Nom. Max. Nominal water Heating pressure drop Water heat exchanger - heat recovery condenser Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water drain Power supply Phase / Frequency / Voltage kW % kW mm kg kg 380 369 460 550 445 521 stepless 25 - 100 65 77.9 90 5.68 5.71 5.79 6.44 6.47 6.56 2,250x3,625x1,551 2,250x3,860x1,551 3,089 3,370 3,603 3,250 3,588 3,870 134 776 1,494 2,455 850 816 129 142 5.65 5.71 7.16 7.23 2,300x4,145x1,743 5,546 5,636 5,911 6,045 Flooded shell and tube 184 932 1,216 2,104 2,339 2,946 3,846 l l/min l/min l/min kPa 78 565 1,058 1,788 35 43 37 51 37 l l/min l/min l/min kPa 83 665 1,244 2,103 111 948 1,499 2,998 133 1,086 1,752 3,435 181 1,478 2,474 4,675 199 1,703 2,746 5,386 35 25 26 28 26 Type dBA 107 615 1,276 1,945 750 734 210 C10 976 167 180 5.81 5.83 7.37 7.40 2,300x4,145x1,910 6,448 6,598 6,972 7,163 281 1,382 2,798 4,370 1,209 2,566 3,825 45 C11 1,050 302 1,632 3,010 5,162 41 34 1,904 3,010 6,020 1,924 3,277 6,085 263 2,146 3,526 6,786 25 29 27 82 82.5 83 230 274 290 243 Shell and tube 78 79 80 °CDB °CDB kg 900 895 Stepless 12.5 - 100 155 5.77 7.32 2,300x4,145x1,808 6,007 6,460 130 165 180 Hz / V 97 81 81.5 Semi-hermetic single screw compressor -8 ~ 15 21 ~ 50 R-134a 200 215 Electronic expansion valve 1 1/2" gas 3~ / 50 / 400 EwWq-B-SS Water cooled chiller, standard efficiency STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› All models are PED pressure vessel approved 1 or 2 stepless single-screw compressors 1 or 2 truly independent refrigerant circuits Optimised for use with R-410A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller MicroTech III STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 10 bar Evaporator Water side design pressure 16 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit & alarm from external device Double pressure relief valve with diverter screw OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Soft starter Brine version Compressor thermal relays Under/overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Evaporator electric heater Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LO N communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 98 EWWQC19,C20B-SS Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger evaporator Water heat exchanger condenser Sound power level Sound pressure level Compressor Operation range Refrigerant Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water pressure drop Cooling Heat exchanger Type Water flow rate Nom. Nominal water pressure drop Cooling Nominal water pressure drop 2 Cooling Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Charge Control Circuits Quantity Charge Charge Evaporator water inlet/outlet Phase/Frequency/Voltage kW % kW mm kg kg 380 380 460 464 85.6 104 4.44 4.46 5.16 5.21 1,849x1,140x3,373 1,933 1,967 2,135 2,169 l kPa 124 47 118 63 l/s kPa kPa dBA dBA 22.2 58 27.2 62 560 562 640 637 25 128 144 4.40 4.41 5.22 2,001x1,276x3,454 2,283 2,332 2,543 2,628 176 43 170 46 730 727 800 796 166 4.37 4.95 1,848x1,314x3,535 2,407 2,777 172 4.64 5.64 2,158x1,350x5,020 3,921 4,422 274 53 344 52 32.9 37.3 42.7 23.1 66 63 15 62 62 100.2 101.2 102.3 101.5 104.7 82.2 83.0 83.9 83.2 84 °CDB °CDB kg kg kg 80 90 80 1 - 2 80 80 860 862 870 872 960 960 C10 C11 C12 C13 C14 1,007 1,055 1,185 1,255 1,325 Stepless 12.5 202 190 209 240 232 256 274 290 4.26 4.59 4.60 4.19 4.55 4.62 4.59 4.56 4.83 5.63 5.59 4.76 5.6 5.61 5.62 5.55 1,848x1,314x2,001 2,158x1,350x5,020 1,848x1,314x2,001 2,378x1,350x4,894 2,455x1,350x5,070 2,427 3,949 3,988 2,457 4,344 4,529 4,536 4,607 2,795 4,463 4,496 2,812 4,780 5,186 5,200 5,280 Shell and tube 266 344 325 251 325 538 48 62 57 55 67 43 48 53 Shell and tube 50.9 23.4 27.9 59.6 27.6 34.3 33.4 38.4 19 62 65 25 65 70 67 65 67 70 67 102.3 104.7 105.1 103.2 104.7 105.2 106.5 84.9 85.2 85 85.6 86 86.5 86.9 Semi-hermetic single screw compressor -4~10 25~45 R-410A 1 2 90 85 100 95 100 90 85 100 95 100 Hz/V 333 367 401 4.38 4.32 4.36 5.18 5.06 2,495x1,350x4,892 4,988 4,999 5,053 5,602 5,615 5,670 505 58 67 42.6 42.7 432 466 4.37 4.40 5.11 5.07 2,495x1,350x4,865 5,204 5,289 5,881 5,970 495 86 539 95 527 119 51 50.8 59.8 14 16 16 18 16 14 105.8 106.2 106.6 107.1 107.5 86.2 86.6 87.0 87.5 87.9 130 130 - 3~/50/400 99 C15 C16 C17 C19 C20 1,460 1,584 1,748 1,888 2,050 EwWq-B-XS Water cooled chiller, high efficiency MicroTech III STRENGHTS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› High efficiency All models are PED pressure vessel approved 1 or 2 stepless single-screw compressors 1 or 2 truly independent refrigerant circuits Shell and tube heat exchanger Optimised for use with R-410A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› screw Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 10 bar Condenser Water side design pressure 16 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit & alarm from external device Double pressure relief valve with diverter OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Soft starter Brine version Compressor thermal relays Under/overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 20mm evaporator insulation 20mm condenser insulation Condenser victaulic kit Cu-ni 90-10 condenser tubes Evaporator electric heater Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM200J) LO N communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 100 EWWQC19-C22B-XS Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger evaporator Water heat exchanger condenser Sound power level Sound pressure level Compressor Operation range Refrigerant Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply Nom. Method Minimum capacity Cooling Nom. kW HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water pressure drop Cooling Heat exchanger Type Water flow rate Nom. Nominal water pressure drop Cooling Nominal water pressure drop 2 Cooling Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Control Circuits Quantity Charge Charge Evaporator water inlet/outlet Phase/Frequency/Voltage mm kg kg % kW 420 422 520 516 640 639 730 725 800 801 25 84.9 102 126 143 4.97 5.03 5.09 5.07 5.86 5.88 5.97 5.95 2,001x1,276x3,863 2,001x1,268x3,878 2,322 2,403 2,464 2,738 2,594 2,685 2,745 3,158 l kPa 220 57 213 70 200 73 334 65 l/s kPa kPa dBA dBA 24.2 50 29.5 40 36.5 41 41.4 46 100.9 101.7 102.6 102.7 82.2 83.0 83.9 °CDB °CDB 1 kg kg Hz/V 95 - 970 973 C10 C11 C12 C13 C14 C15 C16 C17 C19 1,037 1,116 1,158 1,270 1,369 1,449 1,573 1,733 1,863 Stepless 12.5 25 12.5 159 193 205 227 228 252 269 286 315 349 382 5.05 5.06 4.91 5.07 5.04 5.08 5.07 4.99 4.96 4.87 5.89 5.66 6.18 5.54 6.13 6.28 6.23 5.92 6 5.73 2,003x1,314x3,878 2,003x1,446x3,919 2,454x1,350x5,219 2,003x1,446x3,919 2,454x1,350x5,219 2,454x1,350x5,219 2,495x1,350x4,829 2,407 2,427 4,775 2,457 4,831 4,873 4,919 4,969 5,117 5,388 2,815 3,056 5,431 3,086 5,479 5,512 5,546 5,606 5,794 5,843 6,110 Shell and tube 325 538 587 538 575 563 551 495 484 535 58 55 70 65 56 68 76 71 91 93 Shell and tube 45.8 55.7 29.5 64.2 29.6 36.3 36.7 41.2 44.9 44.6 53.3 60 64 39 84 35 48 49 46 43 60 39 48 46 43 62 60 102.0 102.9 105.2 103.8 105.6 106.1 106.5 105.8 106.2 106.6 83.2 84.0 85.6 84.9 86.0 86.5 86.9 86.2 86.6 87.0 Semi-hermetic single screw compressor -4~10 25~45 R-410A 2 1 2 110 130 120 130 120 120 130 120 120 120 130 3~/50/400 101 C20 C21 2,020 2,152 417 1 451 4.84 4.77 5.78 5.64 2,495x1,350x4,865 5,408 5,414 6,118 6,124 527 115 129 53.2 61.9 52 78 79 78 107.1 107.5 87.5 87.9 EwWD-FZXS Water cooled chiller with centrifugal compressor STRENGTHS ›› ›› ›› ›› Wide capacity range from 114 to 1,048 kW An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures Top seasonal efficiency (ESEER up to 9.60) Onboard digital electronics provide smart controls STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Evaporator – 2 passes configuration Evaporator Victaulic kit 20 STD Evaporator water side design pressure 10 bar 20mm evaporator insulation Condenser – 2 passes configuration Condenser Victaulic kit Condenser water side design pressure 10 bar Electronic expansion valve High pressure side manometers Water pressure differential switch on evaporator and condenser Inverter compressor starter Double pressure relief valve with diverter Current limit Hour run meter General fault contactor Set-point reset,demand limit and alarm from external device centrifugal Options ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Evaporator 1/3 passes Evaporator flange kit Evaporator double flange kit Evaporator marine water box (victaulic or flanged) Evaporator water side design pressure 21 bar Condenser 1/3 passes Condenser flange kit Condenser double flange kit Condenser marine water box (victaulic or flanged) Condenser water side design pressure 21 bar 20mm condenser insulation Cu-Ni 90-10 condenser tubes Evaporator/Condenser Flow switch Suction line shut off valve Energy Meter Rubber type antivibration mounts Sound proof system 102 EWWD320-C10FZXS ACCESSORIES ›› ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP) Digital Sequencing Panel (EKDDSP) PlantWatchPRO monitoring system (EKPWPRO) PlantWatchPRO monitoring system (modem & webserver included) EKPWPROM Serial Card RS485/ Modbus (EKAC200J) Ethernet Card BACnet (EKACBAC) Serial Card LON FTT 10 (chiller profile pre-loaded) (EKACLON) ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Serial Card RS232 Modem Interface (single unit only) (EKACRS232) Web Server Card (EKACWEB) Serial Card BACnet MSTP (EKACBACMSTP) Converter RS485 to RS232 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem(EKGSMOD) Remote display kit (EKRUPCK) PlantWatchPro I/O extension module for hardwiring and retrofit (EKPWPROEXT) Gateway web (Ethernet LAN SNMP) (EKGWWEB) Gateway for modem (EKGWMODEM) Cooling only Capacity class Cooling capacity Power input EER Dimensions Weight Water heat exchanger evaporator Sound power level Sound pressure level Compressor Refrigerant Piping connections Power supply Cooling Nom. Nom. kW kw Unit HeigtxWidthxDepth mm Unit kg Operation weight kg Type Cooling Nom. Cooling Nom. Type Type Circuits Quantity Evaporator water inlet/outlet dBA dBA Phase / Frequency / Voltage Hz / V 110 130 110 30.9 3.55 128 38.0 3.36 1,124 1,138 1,141 1,159 145 165 195 143 164 192 43.3 49.8 55.3 3.31 3.30 3.47 1,020x2,684x913 1,237 1,263 1,305 1,253 1,281 1,327 235 265 290 310 330 237 65.2 3.63 265 74.5 3.56 286 86.5 3.31 307 93.0 3.30 328 99.5 3.30 1,489 1,518 1,489 1,518 2,474 2,505 2,500 2,533 2,526 2,562 360 390 430 356 383 429 105 111 121 3.39 3.47 3.56 2,000x2,684x913 2,568 2,611 2,795 2,608 2,655 2,845 470 500 530 474 130 3.63 502 140 3.59 530 149 3.56 2,979 3,036 2,979 3,036 2,979 3,036 73.0 91.0 73.0 91.0 73.0 91.0 Brazed plate, one per circuit 71.4 88.6 71.4 88.6 71.4 88.6 71.4 88.6 71.4 88.6 70.0 70.0 74.4 74.4 74.4 74.4 87.2 87.2 92.4 92.4 92.4 92.4 Semi-hermetic single screw compressor R-134a 1 2 3" 3 / 50 / 400 103 74.4 92.4 73.8 91.8 dwsc/dwdc Water cooled chiller with centrifugal compressor DAIKIN WATER COOLED CHILLERS WITH CENTRIFUGAL COMPRESSORS ›› ›› ›› ›› ›› VARIABLE FREQUENCY DRIVE OPTION (VFD) ›› ›› Single compressor unit up to 4.5MW Dual compressor unit on single circuit up to 9MW Optional variable speed drives (VFD) for superior partload performance Compressor unloading down to 5% for dual compressor units and 10% for single compressor units without hot gas bypass Control flexibility for easy integration into BMS HIGH EFFICIENCY ›› ›› WIDE CHOICE OF CAPACITIES AND EFFICIENCIES Single compressor ›› D-DWSC: 300 kW - 4,500 kW - Approximately 1.1 million possible chiller offerings with combination options of motors, impellers, gears and vessels Dual compressor ›› Inverter technology greatly improving part load efficiency Reducing annual energy costs D-DWDC: 600 kW - 9,000 kW - Approximately 0.75 million possible chiller offerings with combination options of motors, impellers, gears and vessels 104 COP up to 7 at full load COP up to 12 at partial load (when coupled with inverter VFD) UNMATCHED UNLOADING POWER LOSS DAMAGE PROTECTION Unloading to 10% of full load for a D-DWSC single compressor chiller and 5% for a D‑DWDC dual compressor unit, without using inefficient hot gas bypass. This unloading capability provides improved stability of the chilled water temperature and less harmful cycling of compressors. The movable discharge diffuser increases stability and reduces vibrations. Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The compressors are equipped with a lubricant reservoir and a piston with a compressed spring which provides pressurized lubricant to the bearings during the cost-down period. Also, the compressors decelerate quickly due to the low inertia. REFRIGERANT STORAGE CAPABILITY The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate this charge. This feature eliminates the need for separate storage vessels in most applications. Piston Lubricant reservoir Moveable diffuser closing off impeller discharge area EXCELLENT PART LOAD EFFICIENCY LOW OPERATIONAL SOUND LEVEL Liquid Injection When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs to the dual compressor chiller produces a very high ARI certified Integrated Part Load Value (IPLV). A small amount of liquid refrigerant is taken from the condenser and injected into the compressor discharge area. The liquid droplets absorb sound energy and reduce the compressor's overall operational sound level. The droplets evaporate and reduce discharge superheat. Quieter as chiller unloads Daikin’s design results in a reduction in sound levels at lower loads, where most chillers spend most of their operating hours. ONE D-DWDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR CHILLERS ›› ›› ›› ›› ›› ›› PARTIAL LOADS EFFICIENCY FOR 2,000 KW CENTRIFUGAL UNIT Lower equipment costs than two separate chillers Lower installation cost than two separate chillers Lower annual operating cost than either one large or two small chillers Less equipment room space required than for two separate chillers (smaller footprint) Capacity reduction to 5% of design value Standby redundancy for most of the cooling season options of motors, impellers, gears and vessels 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 7.0 D-D 105 9.7 7.4 D- D D-D 10.0 D-D D-DWSC: single compressor D-DWDC: double compressor VFD: compressor inverter Specific selections can vary up or down from this example. Condenserless Chiller Daikin offers you flexible and compact chillers with remote condenser, which can be used to satisfy applications with special requirements in the field of available space, sound level or extreme operating conditions. In these exceptional cases, remote condenser solutions can be preferred over standard air cooled or water cooled solutions. TABLE OF CONTENTS EWlp-kbw1n 108 ewld-J-SS 110 EWLD-g-ss 112 EWLD-i-ss 114 106 1. Temperature sensor 2. Filter 3. Shut-off valve 4. Pump 5. Pressure port 6. Flow switch 7. Drain 8. Pressure gauge 9. Water flow adjusting valve 10. Drain valve 11. Fill valve 12. Safety valve PIPING DIAGRAM FOR COMFORT COOLING APPLICATION 3 2 7 6 5 4 5 1 Expansion To condenser vessel Chillers 12 Evaporator Gas To fan coil units 7 Buffer tank Liquid 3 5 8 9 1 10 11 EWLP-kBW1N Water cooled condenserless chiller STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Daikin scroll compressor Optimised for use with R-407C Electronic DDC controller Low operating sound level Low energy consumption Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Compatible with hydraulic module For EWLP012-065KBW1N following components are standard included: main switch, pressure ports, flow switch, filter, shut-off valves and air purge µC² SE controller µC 2 SE scroll OPTIONS (factory mounted) ›› Chilled water temperature down to - 5°C (ZH) or -10°C (ZL) ACCESSORIES (kit) ›› ›› ›› ›› ›› Hydraulic module (see EHMC-page in this catalogue) Low noise operation EUW*5KZW1 (EKLS1) Low noise operation EUW*8-24KZW1 (EKLS2) Address card for connection to BMS or remote user interface (EKRUMCA) Remote installed user interface (EKAC10C) CONTROL ›› ›› Microprocessor control Water inlet temperature control AVAILABLE INPUTS / OUTPUTS Input ›› ›› Remote ON / OFF Pump contact ›› ›› ›› Compressor operation Summary alarm Pump relay contact Output 108 EWLP012-030KBW1N Cooling only CAPACITY CLASS Capacity Power input Capacity Steps EER Dimensions Weight Water Heat Exchanger Evaporator Compressor Sound Power Operation Range Refrigerant circuit Power Supply Piping connections Cooling Cooling kW kW 012 020 026 030 040 055 065 12.1 4.2 20.0 6.6 26.8 8.5 31.2 10.1 40.0 13.4 62.4 20.3 3.09 2.99 53.7 17.8 2 3.02 600 x 600 x 1,200 265 268 77 154 307 311 89 179 358 mm kg 108 1 3.03 3.15 600 x 600 x 600 141 147 l l/min l/min l/min 62 17 35 69 103 29 57 115 2.88 Height x Width x Depth Machine weight Type Minimum water volume in the system Water flow Min rate Nominal Max Type Model Quantity Cooling Evaporator Min~Max Condensing temperature Min~Max Refrigerant type No of circuits Refrigerant control Evaporator water inlet/outlet Evaporator water drain Liquid line connection Discharge line connection 151 252 Brased plate 134 155 205 38 45 57 77 89 115 153 179 229 Hermetically sealed scroll compressor 1 dBA °CDB °CDB 71 -10(OPZL) ~ 20 25 ~ 60 R-407C 1 67 74 2 Thermostatic expansion valve 3N~/400V/50Hz FBSP 25 FBSP 40 Field installation mm mm 9.52 flare 12.7 flare 12.7 flare 19.1 flare 109 274 2 64 mm 3.07 2x12.7 flare 2x19.1 flare EWld-J-SS Water cooled condenserless chiller MicroTech III STRENGTHS ›› ›› ›› Compact design to allow easy indoor installation or retrofit operations High efficiency at full and partial load MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye-delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit 20 mm evaporator insulation Condenser victaulic kit Condenser Water Side Design 16 bar Condenser 2 passes (dt 4-8 °C) Evaporator flow switch Electronic expansion device Discharge line shut off valve Suction line shut off valve Hour run meter General fault contactor Main switch interlock Emergency stop screw Options ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit display Low pressure side manometers Fork-lift kit Rubber anti vibration mount Sound proof system Set-point reset, demand limit and alarm from external device Double pressure relief valve with diverter Automatic circuit breakers Liquid receiver ACCESSSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communciation module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 110 EWLD120J-SS Cooling only Capacity class Cooling capacity Power input EER Dimensions Weight Water heat exchanger - evaporator Sound power level Sound pressure level Compressor Refrigerant Piping connections Power supply Cooling Nom. Nom. kW kw Unit HeigtxWidthxDepth mm Unit kg Operation weight kg Type Cooling Nom. dBA Cooling Nom. dBA Type Type Circuits Quantity Evaporator water inlet/outlet Phase / Frequency / Voltage Hz / V 110 130 145 110 30.9 3.55 128 38.0 3.36 1,124 1,138 1,141 1,159 143 164 192 43.3 49.8 55.3 3.31 3.30 3.47 1,020x2,684x913 1,237 1,263 1,305 1,253 1,281 1,327 165 71.4 88.6 71.4 88.6 71.4 88.6 71.4 88.6 195 71.4 88.6 235 265 290 310 330 360 237 65.2 3.63 265 74.5 3.56 286 86.5 3.31 307 93.0 3.30 328 99.5 3.30 1,489 1,518 1,489 1,518 2,474 2,505 2,500 2,533 2,526 2,562 356 383 429 105 111 121 3.39 3.47 3.56 2,000x2,684x913 2,568 2,611 2,795 2,608 2,655 2,845 70.0 70.0 74.4 74.4 74.4 74.4 87.2 87.2 92.4 92.4 92.4 92.4 Semi-hermetic single screw compressor R-134a 1 390 74.4 92.4 2 3" 3 / 50 / 400 111 430 73.8 91.8 470 500 530 474 130 3.63 502 140 3.59 530 149 3.56 2,979 3,036 2,979 3,036 2,979 3,036 73.0 91.0 73.0 91.0 73.0 91.0 EWlD-G-SS Water cooled condenserless chiller STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› ›› Cooling range: 161-526kW EER range: 3.54 to 3.55 Stepless single-screw compressor Optimised for use with R-134a 1 or 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› MicroTech III scroll Wye Delta starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 10 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor OPTIONS ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Partial heat recovery Soft starter Brine version Compressor thermal relays Under/ overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 20mm evaporator insulation Evaporator flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter Liquid receiver ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MTSP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 112 EWLD~G-SS Cooling only Indoor units Cooling capacity Capacity steps Power input EER Dimensions Weight Nom. Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Minimum water volume in the exchanger system evaporator Water flow rate Min. Nom. Max. Nominal water Cooling Heat exchanger pressure drop Model Quantity Type Type Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage kW % kW mm kg kg l l/min l/min l/min kPa 160 161 190 240 189 244 stepless 25 - 100 54.3 65.9 3.48 3.70 1,860x1,000x3,700 45.4 3.54 1,280 1,337 280 270 320 316 74.6 3.62 90.6 3.48 1,398 1,516 360 352 380 420 381 428 stepless 12.5 - 100 99.7 108.6 120 3.53 3.51 3.57 1,942x1,100x4,400 2,446 2,501 2,560 2,442 480 476 550 526 131.5 3.62 148 3.55 2,506 2,670 1,151 1,354 1,749 1,938 1,130 1,262 1,365 1,535 1,704 1,884 230.20 460.39 649.15 270.90 541.81 763.95 349.74 699.47 986.26 387.58 775.16 1,092.97 452.22 904.44 1,275.27 504.83 1,009.65 1,423.61 546.25 1,092.50 1,540.42 613.90 1,227.81 1,731.21 681.84 1,363.69 1,922.80 753.80 1,507.60 2,125.71 48 69 43 53 64 63 72 54 68 1 EV19270055 dBA dBA EV27270066 EV27270077 EV27270088 Shell and tube - direct expansion EV32270088 88 90.5 69.7 71.7 EV32270099 Semi-hermetic single screw compressor -8~15 25~60 R-134a °CDB °CDB kg 5 10 Electronic expansion valve 1 2 88.9 114.3 3~ / 50 / 400 Hz / V 113 139.7 EWld-I-SS Water cooled condenserless chiller STRENGTHS ›› ›› ›› ›› ›› ›› ›› ›› Cooling range: 328–1,422kW EER range: 3.51 to 3.91 Stepless single-screw compressor Optimised for use with R-134a Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications MicroTech III screw STANDARD AVAILABLE ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator water side design pressure 10 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Evaporator 1 pass OPTION ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Soft starter Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator water side design pressure 25 bar 20mm evaporator insulation Water pressure differential switch on evaporator Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti-vibration mount Sound proof system Double pressure relief valve with diverter Liquid receiver ACCESSORIES ›› ›› ›› ›› ›› ›› ›› Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM200J) LON communication module (EKCMLON) BACnet/MTSP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 114 EWLD~I-SS Cooling only Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight Nom. Method Minimum capacity Cooling Nom. HeightxWidthxDepth Unit Unit Operation weight Water heat Water flow rate Nom. exchanger Nominal water Cooling Total evaporator pressure drop Type Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage kW % kW mm kg kg l/min kPa dBA dBA 320 328 400 391 420 428 500 504 25 83.8 100 116 137 3.91 3.9 3.7 3.67 1,899x1,464x3,114 1,861 1,869 1,884 2,054 2,052 2,056 940.2 1,120.8 1,227.0 1,444.8 34 47 600 596 650 657 165 3.61 181 3.63 3,331 3,339 3,602 1,708.8 1,883.4 54 49 900 950 C10 C11 C12 C13 C14 C15 C16 919 966 1,033 1,078 1,125 1,188 1,267 1,319 1,370 Stepless 12.5 8.3 198 214 231 252 271 279 296 312 329 347 366 386 3.69 3.67 3.65 3.56 3.59 3.64 3.60 3.61 3.65 3.60 3.55 2,325x1,464x4,391 2,415x2,135x4,426 3,347 3,356 3,364 3,412 5,146 5,167 5,188 5,208 3,603 3,604 3,605 3,645 5,667 5,671 5,677 5,680 2,092.8 2,259.0 2,436.6 2,634.6 2,769.0 2,961.0 3,090.0 3,225.0 3,405.6 3,631.8 3,781.2 3,927.6 39 750 730 800 788 52 850 850 47 45 52 46 49 41 51 55 59 C17 1,422 405 3.51 4,076.4 63 93.7 96.6 96.7 96.9 97.3 97.8 Single pass shell and tube 98.9 99.8 100.4 100.8 101.2 103 100.4 100.8 101.2 103 75.2 76.2 78.2 77.8 78.2 78.7 79.8 80.7 80.4 80.8 Semi-hermetic single screw compressor -8~15 25~60 R-134a 5 Electronic expansion valve 2 °CDB °CDB kg 1 168.3mm Hz / V 83 80.4 3 219.1mm 3~ / 50 / 400 115 81.2 80.8 81.2 83 dicn Daikin Integrated Chiller Network Daikin chillers can be equipped with Daikin Integrated Chiller Network (DICN) which allows the simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant. This function enables a Daikin 2MW chiller plant to be operated via a single controller. Please note that DICN is only possible within the same series. APPLICABLE SERIES: ›› ›› EWAQ080-260DAYN (R-410A) EWYQ080-250DAYN (R-410A) 116 EHMC, EKBT mH2O Hydraulic Module, Buffer Tank PUMP CHARACTERISTICS 55 50 45 40 LEGENDS 35 Pump characteristics 30 1. EHMC30AV1080 2. EHMC10AV1080 & EHMC15AV1080 3. EHMC30AV1010 4. EHMC10AV1010 & 25 20 EHMC15AV1010 15 10 Hydraulic module + filter pressures losses 5 0 5. EHMC15/30AV1010 & EHMC15/30AV1080 6. EHMC10AV1010 & EHMC10AV1080 0 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min) Water flow STRENGTHS ›› ›› ›› ›› ›› 100l buffer tank Freeze-up protection (heater tape) Single pump 12l expansion vessel Standard dual pressure ports Hydraulic module 10 EHMC-AV Nominal flow Nominal static height Nominal input Dimensions (HxWxD) Machine weight Sound power Sound pressure Power supply Operation range Water side Air side Piping connections Water inlet/outlet Drain connection 1010 l/min mH2O W mm kg dBA dBA V1 °C °CDB 15 1080 30 1010 62 1080 1010 88 17 630 34 1,050 15 650 99 101 102 1080 187 27 1,070 10 1,070 27 2,090 104 105 111 1,284x635x688 63 52 1~/230V/50Hz -10°C ~ 55°C -10°C ~ 43°C 2" BSPF 1/2" 1" BSPF 2-1/2" BSPF Buffer tank MODEL Description Volume Dimensions Unit weight Buffer tank with cabinet 200l 1,284x637x754 86,5 EKBT500N Buffer tank 500l 710x1,670 70 EKBTC10N Buffer tank 1,000l 860x2,020 100 EKBT500C Buffer tank with cabinet 500l 1,200x1,200x1,950 160 EKBTC10C Buffer tank with cabinet 1,000l 1,200x1,450x1,950 185 EKBT 117 Fan Coil Units Fan Coil Units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system. These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of Fan Coil Units for both concealed and exposed applications. Three models are available in flexible application. The only moving part in the units is the fan, making them ideal for use in offices, hotels and at home. The goal is to obtain the right solution, both technically and aesthetically. TABLE OF CONTENTS FAn COIL UNIT - accessories 120 FWT-bt  128 FAn COIL UNIT - CONTROL 122 FWb-bt  129 fwv-dt/df 124 fwb-jt/jf 130 fwl-dt/df 125 FWC -bt/bf 131 fwm-dt/df 126 FWF-BT/BF 132 fwd-at/af  127 118 PRODUCT PORTFOLIO FWT-BT Reference 1 2 cooling 3 02 03 4 5 04 05 heating 02 03 04 05 06 07 FWF-BT/BF 10 11 12 16 18 20 22kW 06 08 heating 09 06 cooling 06 07 07 08 09 08 09 4-pipe 06 02 03 04 07 08 09 05 2-pipe heating 02 cooling 02 03 0304 04 05 05 4-pipe heating cooling FWV-DT/DF 9 2-pipe cooling 02 03 04 01 02 03 05 04 06 08 10 2-pipe heating cooling 01 01 02 02 03 04 03 06 08 04 06 08 10 10 4-pipe heating cooling FWL-DT/DF 8 06 heating 01 02 01 03 02 0406 03 08 04 06 08 10 10 2-pipe heating cooling 01 02 01 02 03 04 03 06 04 06 08 08 10 10 4-pipe heating cooling FWM-DT/DF 7 2-pipe cooling FWC-BT/BF 6 01 02 03 02 03 01 04 06 08 04 06 08 10 10 2-pipe heating cooling 01 02 01 02 03 03 04 06 0406 08 08 10 10 4-pipe heating 01 02 cooling 03 04 06 02 03 04 05 08 06 07 02 03 04 08 10 09 10 2-pipe FWB-BT heating cooling 02 03 04 4-pipe* cooling 07 08 09 06 08 09 10 08 09 10 06 04 07 10 05 06 07 08 10 12 16 18 2-pipe heating 04 cooling 04 06 06 08 08 cooling 04 02 03 04 05 06 08 12 08 06 07 12 10 10 4-pipe heating FWB-JT/JF 06 02 03 04 heating FWD-AT/AF 05 05 16 12 10 09 16 18 18 16 18 10 11 2-pipe heating cooling 02 02 03 0405 03 04 06 06 07 07 08 08 09 10 11 10 4-pipe heating (4-pipe) 02 03 04 06 07 08 10 Measuring conditions (at nominal air flow and ESP) : COOLING • air temperature entering the unit: 27°C/19°C • water temperature entering the unit 7°C • leaving the unit 12°C HEATING • room air temperature 20°C • for 2 pipe units : water temperature entering 50°C - water flow rate same as for the cooling test • for 4 pipe units : water temperature entering 70°C - water temperature leaving 60°C. * 4-pipe= 2-pipe + option additional heat exchanger 119 Fan Coil Unit - accessories Type: FWM-DT/DF, FWL-DT/DF, FWV-DT/DF Description Additional single row heat exchanger Electric heater 2-pipe 3-way valve 4-pipe 3-way valve Fan stop thermostat Air intake & discharge grille Supporting feet Supporting feet + grille Fresh air intake Rear panel Control electromechanical Electronic controller Master slave option Vertical drainpan Horizontal drainpan On board installation kit Temperature sensor kit Relative humidity sensor kit On board FCU controller installation kit 1 2 3 ESRH02A6 4 ESRH03A6 ESRH06A6 EAIDF02A6 ESFVG2A6 EFA2A6 ERPV2A6 EEH06A6 E2MV06A6 E4MV06A6 YFSTA6 EAIDF03A6 EAIDF06A6 ESFV06A6 ESFVG3A6 ESFVG6A6 EFA3A6 EFA6A6 ERPV3A6 ERPV6A6 ECFWMB6 FWEC1A, FWEC2A, FWEC3A EPIMSB6 EDPVA6 EDPHA6 FWECKA FWTSKA FWHSKA 10 FWV FWL FWM ESRH10A6 x x x EEH10A6 E2MV10A6 E4MV10A6 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x - EAIDF10A6 ESFV10A6 ESFVG10A6 EFA10A6 ERPV10A6 FWECKA 2-4 5-7 8-10 EAH04A6 EAH07A6 EAH10A6 E2MV310A6 E2MV307A6 Factory mounted E2MV207A6 Factory mounted Factory mounted YFSTA6 EPIMSB6 FWEC1A FWEC2A FWEC3A FWTSKA FWHSKA FWECKA - Electronic controller Temperature sensor kit Relative humidity sensor kit On board installation kit Type: FWB-JT/JF Description 2-pipe 3-way valve 4-pipe 3-way valve E2MV210A6 4 6 8 10 (1) TYPE Description Standard wired remote control Simplified wired remote control Simplified wired remote control Wireless control for cooling only Wireless control for heat pump Decoration Panel (RAL 9010 grey sealings) 4-way blow Decoration Panel - Standard (RAL 9010 - grey sealings) Round flow Decoration Panel - White (RAL 9010 - white sealings) Round flow Sealing member of air discharge outlet EPIB6 16 18 EDEHS12A6 EDEHS18A6 EDEHB12A6 EDEHB18A6 ED2MV12A6 ED2MV18A6 2xED2MV12A6 2 x ED2MV18A6 EDDPV18A6 EDDPH18A6 EDMFA12A6 EDMFA18A6 Requires electronic controller For FWD 12,16,18AT/AF only motor valve (piping not included) Water probe included Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall. 5. Requires electrical installation box with earth terminal KJB311A. 6. Requires electrical installation box KJB411A. 7. Requires installation box KRP1H98. (FWC) 8. Requires installation box KRP1BA101 (FWF) 9. Requires electrical installation box with earth terminal KJB212A, if built in the wall. 10. Requires valve control PCB EKRP1C11 11. I-touch: • Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible.» 12. 13. 14. 15. 16. 17. 18. 19. 20. 120 FWC-BT/BF FWF-BT/BF MERCA - - SRC-COB - - SRC-HPB - - WRC-COB - - WRC-HPB - - - - BYFQ60B - BYCQ140CW1 - BYCQ140CW1W - KDBHQ55C140 KDBH44BA60 Panel spacer - - KDBQ44B60 - KAFP551K160 KAFQ441BA60 Fresh air intake kit - Direct installation type - - KDDQ44XA60 Fresh air intake kit (20% fresh air) - Direct installation type - KDDQ55C140-1 (*20) / KDDQ55C140-2 (*20) - - BRC7F532F (*18) BRC7E530 (*18) - BRC7F533F (*18) BRC7E531 (*18) Remote controller - Wired - Central remote controller - BRC315D7 (*4) DCS302CA51 (*5) Electrical box with earth terminal (3 blocks) - KJB311A Unified on/off controller - DCS301BA51 (*9) Electrical box with earth terminal (2 blocks) - Schedule timer - Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) Installation box for adapter PCB 12 FWT Long-life filter Remote controller - Wireless - H/P Remote controller - Wireless - C/O MCWCN MCWHN EDEH04A6 EDEHS06A6 EDEHS10A6 EDEH04A6 EDEHB06A6 EDEHB10A6 ED2MV04A6 ED2MV10A6 (2) ED4MV04A6 ED4MV10A6 EDDPV10A6 EDDPH10A6 YFSTA6 EDMFA04A6 EDMFA06A6 EDMFA10A6 FWEC1A Electronic controller (3) FWEC2A FWEC3A Power interface EPIB6 Master slave interface EPIMSA6 Temperature sensor kit FWTSKA Relative humidity sensor kit FWHSKA 1. 2. 3. 4. 8 EEH01A6 EEH02A6 EEH03A6 E2MV03A6 E4MV03A6 Type: FWB-BT Description Additional heat exchanger 3-way valve add. h/e 3-way valve cooling h/e 2-way valve add. h/e 2-way valve cooling h/e Electric Heater Fan stop thermostat Power interface Master slave interface Type: FWD-AT/AF Description Electric heater: small Electric heater: big 2-pipe 3-way valve 4-pipe 3-way valve Vertical Drainpan Horizontal Drainpan Fan stop thermostat Fresh air intake 6 Remote sensor - Intelligent touch controller - Electrical installation box - KJB212A DST301BA51 (*6)(*9) KRP2A52 (*7) (*12) KRP4AA53 (*7) (*12) DST301BA51 (*6)(*9) KRP2A52 (*9) (*12) KRP4AA53 (*9) (*12) KRP1H98 (*13) KRP1BA101 (*17) KRCS01-4 KRCS01-1 DCS601C51C(*6) DCS601C51C (*6) (*11) (*11) KJB411A Optional PCB for MOD-bus connection - 2-way valve - On/Off - 3-way valve - On/Off - EKFCMBCB7 (*8) EKFCMBCB7 (*8) (*12) (*12) EKMV2C09B7 EKMV2C09B7 (*8) (*10) (*15) (*8) (*10) (*16) EKMV3C09B7 EKMV3C09B7 (*8) (*10) (*15) (*8) (*10) (*16) Valve control PCB - EKRP1C11 Remote “On/Off” and “forced off” kit - EKROROA (*17) Only 1 of these 4 options can be installed on 1 indoor unit. Max. 1 KRP1H98 box can be mounted on the unit. Max. 2 PCB’s can be mounted in 1 KRP1H98 box. (FWC) Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1PCB can be mounted in 1 KRP1BA101 box. (FWF) 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C 11 (FWC) 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 (FWF)» This option is needed to create T1 T2 wire. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the “auto airflow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC model. All options are supplied as kit. Both parts of the fresh air intake are needed for each unit. Fan Coil Unit - control The fan coil units ELECTRONIC Controller ›› can be operated by different controllers ›› ›› FWEC1A according ›› to the model. ›› ›› ELECTROMECHANICAL BUILT-IN CONTROLLER ›› ›› Fan speed selector Manual cooling/heating changeover. ON / OFF valves can also be controlled with ECFWMB6 ECFWMB6 ›› ›› ›› ›› FWEC2A WIRED REMOTE CONTROLLER ›› ›› ›› to control each fan coil unit independently cooling and heating function ON/OFF timer function ›› BRC315D7 ›› ›› FWEC3A INFRARED REMOTE CONTROLLER ›› ›› to control each fan coil unit independently cooling and heating function BRC7E532F 122 Control of on-off valves for two or four pipes systems Control of auxiliary heating element Cooling/heating switching in the following modes: local or remote manual (centralised), automatic (depending on water temperature (optional) or air temperature) Possibility, by means of clean contacts, of remote centralised cooling/heating switching and external activation Temperature sensor kit (accesory FWTSKAA) Economy function (setpoint correction by 2.5°C and forcing of the fan to run at minimum available speed) Composed by: lc display keyboard On board and wall mounted installation. Same as FWEC1AA with following additional functions: 1) humidity management: - display of relative humidity - dehumidification function (cooling mode) Manual activation 2) serial communication interface (RS485 bus) - possibility to set up a masterslave system up to 247 slave units, inwhich one of the controls plays the role of master and manages all the other slave units. ( modbus protocol ) Composed by: lc display keyboard On board and wall mounted installation. Same as FWEC2AA with following additional functions: 1) Back light 2) Proportional valve control (two voltage outputs for the proportional valves) 3) Voltage contact 0-10V (same as 2) 4) Time clock and weekly schedule (on / off or setpoint air) 5) Integration in BMS (already included in the FWEC2AA version) 6) Two digital outputs (voltage free) to manage electric heaters with the weekly schedule STANDARD WIRED REMOTE CONTROLLER MERCA ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Fan speed Sleep function Swing Temperature setting Operating mode LCD display ON / OFF switch Real time clock Timer active Timer ON / OFF SIMPLIFIED WIRED REMOTE CONTROLLER FOR COOLING ONLY & HEAT PUMP SRC-COB SRC-HPB ›› ›› ›› ›› ›› ›› ›› ›› Temperature display Temperature setting Timer switch setting ON / OFF switch Fan speed Operating mode Swing “Sleep” function WIRELESS CONTROLLER FOR COOLING ONLY & HEATPUMP WRC - COb/HPB 123 ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› LCD display Temperature setting Operating mode Timer switch setting Turbo mode Swing “Sleep” function Real time clock ON / OF switch Fan speed FWV-DT/DF Floor standing unit FWEC1, 2, 3A FWV01, 02DT/DF ›› ›› ›› ›› ›› ›› ›› ›› ›› ECFWMB6 Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater : no relay up to 2kW capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit High High kW kW High High kW kW W HeightxWidthxDepth mm Unit Water volume Water volume Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Piping connections Drain OD Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High 01 1.54 02 2.09 2-PIPE 04 4.33 06 4.77 08 6.71 10 8.02 01 1.46 02 1.90 03 2.87 4-PIPE 04 4.33 06 4.67 08 6.64 10 7.88 1.14 1.51 2.07 3.15 3.57 4.85 5.85 1.20 1.51 2.11 3.15 3.65 4.91 5.96 2.14 2.57 3.81 5.63 - 6.36 7.83 10.03 37 53 564x774x226 kg l l 19 0.5 20 0.7 l/h l/h kPa kPa 265 265 359 359 m³/h dBA mm inch Hz / V A 03 2.93 56 98 564x984 564x1,194x226 x226 25 30 31 1 1.4 137 175 564x1,404x251 41 2.1 1.90 2.10 37 53 564x774x226 20 0.5 504 504 11 745 745 12 820 1,154 1,343 820 1,154 1,343 13 14 12 19 9 11 9 10 9 16 Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 45 50 47 52 56 58 64 16 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76 124 21 0.7 0.2 251 196 5.05 3.08 5.30 56 98 564x984 564x1,194x226 x226 26 32 33 1 1.4 0.3 327 182 0.4 7.91 9.30 137 175 564x1,404x251 44 2.1 0.6 494 745 803 1,142 1,355 286 396 465 694 816 13 11 12 14 12 19 7 8 5 10 8 9 Centrifugal multi-blade, double suction 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 16 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76 FWL-DT/DF Flexi type unit FWL03DT/DF ›› ›› ›› ›› ›› ›› ›› ›› ›› FWEC1, 2, 3A FWL03DT/DF ECFWMB6 Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater : no relay up to 2kW capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit High High kW kW High High kW kW W HeightxWidthxDepth mm Unit Water volume Water volume Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High 01 1.54 02 2.09 2-PIPE 04 4.33 06 4.77 08 6.71 10 8.02 01 1.46 02 1.90 03 2.87 4-PIPE 04 4.33 06 4.67 08 6.64 10 7.88 1.14 1.51 2.07 3.15 3.57 4.85 5.85 1.20 1.51 2.11 3.15 3.65 4.91 5.96 2.14 2.57 3.81 5.63 - 6.36 7.83 10.03 37 53 564x774x226 kg l l 20 0.5 21 0.7 l/h l/h kPa kPa 265 265 359 359 m³/h dBA inch Hz / V A 03 2.93 56 98 564x984 564x1,194x226 x226 27 32 33 1 1.4 137 175 564x1,404x251 44 2.1 1.90 2.10 37 53 564x774x226 21 0.5 504 504 11 745 745 12 820 1,154 1,343 820 1,154 1,343 13 14 12 19 9 11 9 10 9 16 Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 45 50 47 52 56 58 64 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76 125 22 0.7 0.2 251 196 5.05 3.08 5.30 56 98 564x984 564x1,194x226 x226 28 34 35 1 1.4 0.3 327 182 0.4 7.91 9.30 137 175 564x1,404x251 46 2.1 0.6 494 745 803 1,142 1,355 286 396 465 694 816 13 11 12 14 12 19 7 8 5 10 8 9 Centrifugal multi-blade, double suction 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76 FWM-DT/DF Flexi type unit FWM01, 02DT/DF ›› ›› ›› ›› ›› ›› ›› ›› ›› FWEC1, 2, 3A FWM01, 02DT/DF Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater: no relay up to 2kW capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit Unit Water volume Water volume 01 1.54 02 2.09 03 2.93 2-PIPE 04 4.33 06 4.77 08 6.71 10 8.02 01 1.46 02 1.90 03 2.87 4-PIPE 04 4.33 06 4.67 08 6.64 10 7.88 1.14 1.51 2.07 3.15 3.57 4.85 5.85 High High kW kW 1.20 1.51 2.11 3.15 3.65 4.91 5.96 High High kW kW W mm kg l l 2.14 2.57 3.81 5.63 - 6.36 7.83 10.03 l/h l/h kPa kPa 265 265 HeightxWidthxDepth Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Piping Drain OD connections Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High m³/h dBA mm inch Hz / V A 37 53 535x584x224 14 15 0.5 0.7 56 535x794x224 19 1 98 535x1,004x224 23 1.4 137 175 535x1,214x249 32 2.1 1.90 2.10 37 53 535x584x224 15 16 0.5 0.7 3.08 56 535x794x224 20 1 5.30 98 535x1,004x224 25 1.4 7.91 9.30 137 175 535x1,214x249 34 2.1 0.2 0.3 0.4 0.6 359 359 504 504 11 745 745 12 820 1,154 820 1,154 13 14 12 9 11 9 10 9 Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 45 50 47 52 56 58 1,343 1,343 19 16 1,393 64 251 196 327 182 494 745 803 1,142 286 396 465 694 13 11 12 14 12 7 8 5 10 8 Centrifugal multi-blade, double suction 307 327 431 690 763 998 45 50 47 52 56 58 17 0.17 0.24 3/4 126 1,355 816 19 9 1,362 64 17 1/2 1~ / 50 / 230 0.25 0.44 0.43 5.05 0.60 1/2 0.76 0.17 0.24 1~ / 50 / 230 0.25 0.44 0.43 3/4 0.60 0.76 FWD-AT/AF Flexi type unit FWD04AT/AF ›› ›› ›› ›› FWEC1,2,3A FWD04AT/AF Quick fixing system for wall or ceiling mounted installation Straight duct connector is mounted to discharge side Electronic controller with water probe, available in standard, advanced and advanced plus version The air filter can easily be removed for cleaning Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit Unit Water volume Water volume High High High High HeightxWidthxDepth Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Available pressure High Sound power level High Piping connections Drain OD Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High kW kW kW kW W mm kg l l 04 3.90 3.08 4.05 06 6.20 4.65 7.71 234 349 280x754x559 280x964x559 33 41 1.06 1.42 2-PIPE 10 12 16 18 8.82 11.90 16.40 18.30 7.16 9.36 12.80 14.10 10.79 14.45 19.81 21.92 443 714 1,197 280x1,174x559 352x1,174x718 352x1,384x718 47 49 65 77 80 1.79 2.38 2.5 4.02 5.03 08 7.80 6.52 9.43 - l/h l/h kPa kPa 674 674 17 14 m³/h Pa dBA mm inch Hz / V A 800 66 66 0.95 1,064 1,064 1,339 1,339 1,514 2,056 2,833 3,140 1,514 2,056 2,833 3,140 24 16 26 34 45 20 13 21 28 37 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 58 68 64 97 145 134 69 72 74 78 16 3/4 1 1~ / 50 / 230 1.58 1.97 3.21 5.37 127 04 3.90 3.08 06 6.20 4.65 4.49 6.62 234 349 280x754x559 280x964x559 35 43 1.06 1.42 0.35 0.47 674 349 17 9 1,064 581 800 63 66 0.95 4-PIPE 10 12 16 18 8.82 11.90 16.40 18.30 7.16 9.36 12.80 14.10 9.21 15.86 21.15 443 714 1,197 280x1,174x559 352x1,174x718 352x1,384x718 50 52 71 83 86 1.79 2.38 2.50 4.02 5.03 08 7.80 6.52 0.59 1,339 1,514 1.42 1.72 2,056 2,833 3,140 808 1,392 1,856 24 16 26 34 45 15 13 12 16 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 53 63 59 92 138 128 69 72 74 78 16 3/4 1 1~ / 50 / 230 1.58 1.97 3.21 5.37 FWT-BT Wall mounted unit FWT05, 06BT ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› MERCA SRC-COB/HPB WRC-COB/HPB Wide operating range Easy installation and maintenance 3-speed fan motor Double-intake centrifugal fans Excellent air flow and air distribution Flexibility via interchangeable water connection side High power air flow Insulated with self-extinguishing class 1 heat insulation Removable washable air filter (self-extinguishing class 1) Slim and compact aesthetic design Wireless remote control up to 9m distance, availability of a wired or simplified controller LED indicator gives an indication on the (normal or wrong) operation of the unit Indoor units Cooling capacity Total capacity High Sensible High capacity Heating capacity 2-Pipe High Power input High HeightxWidthxDepth Dimensions Unit Weight Unit Operation weight Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Sound pressure level High Piping connections Drain OD Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High kW kW kW W mm kg kg l l/h l/h kPa kPa m³/h dBA dBA mm inch Hz / V A 02 2.34 2-PIPE 04 3.22 03 2.78 05 4.54 06 5.28 1.74 2.03 2.35 3.65 4.33 3.02 24 260x799x198 10 10 0.49 402 402 48.3 42 3.75 25 4.10 29 6.01 66 6.74 69 260x899x198 12 13 0.57 478 478 64.7 58.6 467 510 53 40 39 16 554 554 69.3 60.6 Centrifugal-direct driven fan motor 586 55 42 128 781 781 50.3 50.6 908 908 69.3 70.6 1,070 61 49 1,121 64 50 20 1/2 1~ / 50 / 220-240 0.13 0.11 304x1,062x222 16 17 0.85 0.29 0.30 FWB-BT Concealed ceiling unit FWEC1, 2, 3A FWB04BT ›› ›› ›› ›› ›› ›› ›› Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Compact dimensions, can easily be mounted in a narrow ceiling void 3, 4 or 6 stage row cooling coil Drain pan to collect the condensate from: heat exchanger and regulating valves 7-speed electrical motors (with thermal protection on windings) All 7 speeds pre-wired in the factory in the terminal block of the switch box The air filter can easily be removed for cleaning Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Total capacity High Sensible capacity High 2-Pipe High 4-Pipe High High HeightxWidthxDepth Unit Unit Operation weight Water volume Water volume Cooling Heating Additional heat exchanger Water pressure Cooling drop Heating Additional heat exchanger Fan Type Air flow rate High Available pressure High Sound power level High Sound pressure level High Piping connections Drain OD Water connections Std. heat exchanger Add. heat exchanger Power supply Phase / Frequency / Voltage Current input High kW kW kW kW W mm kg kg l l l/h l/h l/h kPa kPa kPa m³/h Pa dBA dBA mm inch inch Hz / V A 02 2.61 1.88 5.47 23 24 1.1 03 3.14 2.16 6.01 3.14 79 239x1,039x609 24 26 1.5 04 3.49 2.34 6.47 05 5.08 3.6 10.31 26 28 2.2 31 33 1.6 598 567 873 904 0.4 448 480 8 7 539 527 275 14 10 3 2-PIPE 06 5.45 3.87 11.39 5.99 154 239x1,389x609 33 35 2.1 07 6.47 4.4 12.28 08 7.57 5.23 15.05 35 38 3.2 43 45 2.1 09 8.67 5.96 16.85 12.8 294 239x1,739x609 45 48 2.8 0.6 936 1,111 1,299 999 1,077 1,319 526 11 15 8 14 8 12 7 10 16 5 Centrifugal - forward blades - directly coupled on fan motor 800 65 59 47.5 16 3/4 3/4 1~ / 50 / 230 0.73 400 71 56 44.5 0.36 129 10 10.34 6.9 18.78 48 52 4.2 1.7 1,488 1,479 1,123 21 15 8 1,200 59 69 57.5 1 1.28 1,774 1,647 26 18 FWB-JT/JF Concealed ceiling unit FWEC1, 2, 3A FWB02JT/JF ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› Wide operating range Quiet operation via enlarged fan wheels Easy maintenance: filter can be removed from both sides and beneath (maximum filter size is 400mm) Flexibility (2-pipe or 4-pipe) 4-speed fan motor Direct driven centrifugal fans Flexibility via interchangeable water connection side High power air flow Available static pressure of 30 Pa Extended drain pan as standard Standard Filter Standard Plenum Insulated with self-extinguishing class 1 heat insulation Electronic room thermostat Indoor units 2-PIPE 4-PIPE 06 07 08 09 10 11 02 03 04 06 07 2-PIPE 4-PIPE 02 03 04 05 06 07 08 09 10 11 02 03 04 06 07 1.64 2.67 2.99 3.34 4.81 5.31 6.16 7.26 8.49 8.99 1.67 2.67 3.03 4.88 5.33 0.94 1.88 1.95 2.07 3.40 4.15 4.39 5.06 6.37 6.41 0.97 1.83 1.93 3.41 4.01 2.16 3.62 3.97 4.11 6.30 7.47 8.09 9.64 11.57 11.71 2.12 3.69 3.87 6.40 7.52 2.49 3.92 4.43 6.70 8.16 34 53 57 54 86 121 117 134 164 166 34 51 54 84 117 251x814 251x984 251x1,314 251x1,664 251x814 251x984 251x1,114 251x1,314 251x1,564 251x1,114x590 251x1,564x590 251x1,924x590 x590 x590 x590 x590 x590 x590 x590 x590 x590 20.0 23.0 28.0 31.0 33.0 44.0 48.0 52.0 50.0 56.0 22.0 27.0 31.0 36.0 48.0 20.7 24.0 29.1 32.5 34.4 45.8 50.4 54.6 52.4 59.1 22.9 28.3 32.5 37.9 50.4 0.69 0.95 1.14 1.52 1.44 1.82 2.42 2.62 2.36 3.14 0.92 1.26 1.52 1.92 2.42 386 549 739 803 1,022 1,109 1,383 1,523 1,764 1,910 386 530 724 986 1,138 386 549 738 802 1,020 1,107 1,336 1,524 1,764 1,911 387 530 725 985 1,139 269 391 493 663 820 10.91 8.34 15.64 11.22 31.31 12.56 7.62 9.83 21.71 16.81 10.95 8.24 15.67 29.95 9.24 8.86 6.76 12.84 9.21 25.87 11.13 6.57 8.60 18.56 14.46 8.94 6.64 12.84 24.16 7.89 10.66 24.73 41.72 81.63 25.31 Direct driven centrifugal fan (forward-curved blades)hot-galvanised steel 262 428 431 428 757 945 950 1,066 1,463 1,341 220 424 437 747 898 30 30 47.5 52 49 50 52 55 55.5 56 47 52 50 52 35.5 40 37 38 40 39.5 43 43.5 44 35 40 38 40 39.5 714 884 1,014 1,214 1,464 1,564 1,824 714 884 1,014 1,214 1,464 3/4 3/4 1~ / 50 / 220-240 1~ / 50 / 220-240 0.15 0.24 0.26 0.25 0.39 0.55 0.53 0.61 0.75 0.15 0.23 0.25 0.38 0.53 02 Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit High High High High HeightxWidthxDepth Unit Operation weight Heat exchanger Water volume Water flow Cooling Heating Additional heat exchanger Water pressure Cooling drop Heating Additional heat exchanger Fan Type Air flow rate High Available pressure High Sound power level High Sound pressure level High Piping connections Drain OD Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High kW kW kW kW W mm kg kg l l/h l/h l/h kPa kPa kPa m³/h Pa dBA dBA mm inch Hz / V A 03 04 05 130 08 10 08 6.53 4.91 9.01 9.56 137 251x1,664 x590 52.0 54.6 2.62 1,296 1,299 924 12.49 9.67 31.33 10 8.21 6.28 11.09 11.68 163 251x1,924 x590 56.0 59.1 3.14 1,660 1,660 1,142 19.38 16.50 50.03 1,112 1,385 55 56 43 44 1,564 1,824 0.62 0.74 FWC-BT/BF Round flow cassette FWC-BT/BF ›› ›› ›› ›› ›› ›› BRC315D7 BRC7E532F 360° air discharge ensures uniform air flow and temperature distribution Modern style decoration panel in white (RAL9010) Fresh air intake for healthy living Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling Possibility to shut 1 or 2 flaps for easy installation in corners Standard drain pump with 850mm lift Indoor units Cooling capacity Total capacity High Sensible High capacity Heating capacity 2-Pipe High 4-Pipe High Power input High HxWxD Dimensions Unit Weight Unit Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Sound pressure level High Power supply Phase/Frequency/Voltage 2-PIPE kW kW 4-PIPE FWC06BT 5.0 FWC07BT 5.6 FWC08BT 6.3 FWC09BT 7.2 FWC06BF 4.9 FWC07BF 5.6 3.4 3.9 3.4 4.0 4.5 5.3 kW kW W mm kg kPa kPa 6.3 7.1 8.3 9.5 40 46 58 76 m³/h dBA dBA Hz/V 1,062 36 24 - 19 19 26 26 Turbo fan 1,236 1,518 39 44 28 32 1~/50/220-240 131 FWC09BF 7.2 4.4 5.2 7.8 59 8.8 77 25 38 32 47 6.2 41 6.8 47 34 34 15 24 29 19 30 1,776 49 37 1,032 36 24 288x840x840 26 15 15 FWC08BF 6.3 288x840x840 Turbo fan 1,200 1,476 39 44 28 32 1~/50/220-240 1,746 49 37 FWF -BT/BF 4-way blow ceiling mounted cassette FWF-BT/BF ›› ›› ›› ›› ›› BRC315D7 BRC7E532F Modern stylish decoration panel in white (RAL9010) Fresh air intake kit available Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling Possibility to close 1 or 2 flaps for different air flow patterns Drainpump standard mounted (lift: 750mm) Indoor units Cooling capacity Sensible capacity Heating capacity Power input Dimensions Weight Water pressure drop Fan Sound power level Sound pressure level Power supply 2-PIPE Total capacity High kW 2-Pipe 4-Pipe High Unit Unit Cooling Heating Type Air flow rate High High High kW kW kW mm kg kPa High HxWxD FWF02BT 1.7 1.3 2.6 FWF03BT 2.8 1.7 3.4 4-PIPE FWF04BT 3.3 2.1 4.1 FWF05BT 4.0 2.7 5.3 67 FWF02BF 1.7 1.3 FWF03BF 2.3 1.3 3.3 62 m³/h dBA dBA Phase / Frequency / Voltage Hz / V FWF05BF 3.5 2.3 3.9 74 4.8 93 20 21 9 20 33 13 - 70 89 3.1 67 19 31 31 19 42 42 19 6 12 20 13 6 285x575x575 285x575x575 19 6 6 19 19 19 468 468 660 876 468 438 618 822 40 40 44 49 40 42 46 51 27 27 33 39 27 29 35 41 Turbo fan High FWF04BF 2.8 1.7 Turbo fan 1~ / 50 / 220-240 132 1~ / 50 / 220-240 Daikin Air handling units D-AHU Professional The D-AHU Professional is based on a completely modular design, capable of adapting to the needs of a variety of installation types. A wide standard range covers air flow rates from 1,100m³/h up to 124,000m³/h while paying special attention to energy efficiency. System highlights ›› Custom modular design with variable dimensioning ›› Rigid 40mm and 60mm extruded aluminium profile structure ›› Double wall 25mm and 50mm foam or rockwool filled panels ›› Component flexibility for total air treatment: Heat Recovery & Humidification ›› Air flow rates from 1,100 up to 124,000m3/h Aluminium profile with thermal break Robust thermal-break construction The air handling unit is constructed of aluminium, using anodised aluminium profiles and double-walled panels. The profiles have a section of 40x40mm or 60x60mm. The 60x60mm profiles are also available in a thermal-break v­ ersion. The following insulation material is used between the sheets: ›› Polyurethane foam (40-50 kg/m3) ›› Mineral wool, glued to the panel (90 kg/m3) ›› ›› ›› ›› ›› Plastisol Galvanised steel Aluminium Stainless steel Pre-painted D-AHU Professional 19-27 Model size Model size D-AHU Professional 10-18 Model size D-AHU Professional 01-09 The panels are available as flat panels or as step panels, which permit to obtain a flat surface inside the unit. The inner and outer sheet of the panel can be made with the following materials: Speed 2.0 m/s Speed 2.5 m/s Speed 3.0 m/s Speed 3.5 m/s Air flow rate (m3/h) x 1,000 Air flow rate (m3/h) x 1,000 134 Speed 2.0 m/s Speed 2.0 m/s Speed 2.5 m/s Speed 2.5 m/s Speed 3.0 m/s Speed 3.0 m/s Speed 3.5 m/s Speed 3.5 m/s Air flow rate (m3/h) x 1,000 174 DAIKIN AIR HANDLING UNITS «  O f fe r i n g a complete range: from standard model sizes to customised soluti o n s.  » COMPONENTS OF THE D-AHU PROFESSIONAL Humidifiers ›› Surface evaporation humidifier ›› Water spray humidifier ›› Steam humidifier (on network with generator) ›› Atomized water spray humidifier Centrifugal fans ›› Forward bladed fans ›› Backward bladed fans ›› Centrifugal fan ›› Belt or direct drive Heat exchangers ›› Material: - Cu/Al - Cu/Al prepaint - Cu/Cu - galvanised Fe - RVS304 - RVS316 ›› Water coil ›› Steam coil ›› Direct expansion coil ›› Superheated water coil ›› Electric coils Other ›› Damper ›› Mixed section ›› Empty section ›› Gas burner section ›› Drip tray Damper BASIC SPECIFICATIONS Heat recovery ›› Heat wheel ( efficiency 70 - 75%) ›› Plate heat exchanger (efficiency 50 - 60%) ›› Twincoil heat exchanger (efficiency 50 - 60%) Heat recovery wheel Filters ›› Pre-filters: - Pleated filter (G3,G4) - Flat filter (G1,G2) ›› Medium efficiency filter: - Bag filters (rigid or soft) (F5 - F9) ›› High efficiency filters (up to H13) ›› Active carbon filters - Adsorption filters - Deodorizing filters Model size Air flow rate at 2.5m/s Length Height 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1,105 1,550 1,980 2,570 3,170 3,550 4,000 4,800 5,560 6,600 7,950 9,320 10,050 13,200 19,200 25,300 31,500 37,000 43,400 51,300 58,000 67,500 78,000 84,700 98 000 111,000 124,000 850 900 950 1,000 1,150 1,150 1,250 1,300 1,350 1,550 1,550 1,650 1,650 1,850 2,100 2,650 2,750 3,220 3,090 3,340 3,820 4,040 4,490 4,490 4,890 5,490 5,990 550 600 650 780 780 800 800 850 900 900 1,100 1,100 1,150 1,400 1,500 1,500 1,750 1,800 2,100 2,250 2,250 2,400 2,450 2,700 2,850 2,850 3,000 16 17 18 19 20 21 22 23 24 25 26 27 135 DAIKIN AIR HANDLING UNITS D-AHU Easy Range The range covers an area of air flow rates from 500 m3/h up to 30.000 m3/h*, with the possibility to choose the more appropriate face velocity, depending on the treatment required. Pre defined sizes Fifteen fixed sizes optimized to reach the best compromise b.etween competitiveness and manufacturing standardization Variable DimensioningTM Designed to overcome installation constraints where space requirements of the section “height x width” must be adapted to the available space. The system gives the possibility to tailor the unit sizes through increments of 5 cm average. Pre defined sizes - Overall dimension Air Flow (m3/h) Speed 2.5 m/s 1.105 1.550 1.980 2.600 3.170 3.550 4.000 4.800 5.560 6.600 7.950 9.320 10.050 13.200 19.200 Size Std 1 Std 2 Std 3 Std 4 Std 5 Std 6 Std 7 Std 8 Std 9 Std 10 Std 11 Std 12 Std 13 Std 14 Std 15 Height - mm Width - mm 550 600 650 780 780 800 800 850 900 900 1.100 1.100 1.150 1.400 1.500 850 900 950 1.100 1.150 1.150 1.250 1.300 1.350 1.550 1.550 1.650 1.650 1.850 2.100 Example Air Flow (m3/h) Unit Size Height - mm Width - mm 15.000 STD 15 1.500x1.700 1.500 1.500 2.100 1.700 Face Velocity m/s 1.95 2.48 Infinitely variable sizes Flexible sizing for AHU optimization • 5 cm increment for width & height dimensions • No additional cost for non-standard unit size • No additional lead time *Air Flow limits of 500 m3/h and 30.000 m3/h are calculated using non standard sizes (max dimensions 2.150x2.150) and considering 2,5 m/s coil face velocity 7 7 6 6 5 5 4 3 2 2 0 0.5 3.170 3.170 2.600 2.600 1.980 1.980 Speed 2.0 m/s Speed 2.0 m/s Speed 2.5 m/s Speed 2.5 m/s 1.550 1.550 Speed 3.0 m/s Speed 3.0 m/s 3 1.105 (m2.5 /h)m/s) (Speed 2.5 m/s) 1.105 (m3/h) (Speed 1 1 4.000 3.550 3.550 4 3 4.800 4.800 4.000 10 0.5 1.5 1 2 1.5 2.5 2 3 2.5 3.5 3 4 3.5 4.5 54 4.5 5.5 5 6 5.5 6.5 6 7 6.5 7.5 15 15 14 14 13 13 Size 8 D-AHU Easy 9-15 Size 8 Size Size D-AHU Easy 1-8 12 7 7.5 13.200 13.200 10.050 10.050 12 9.320 9.320 11 11 10 10 6.600 7.950 7.950 Speed 2.0 m/s Speed 2.0 m/s Speed 2.5 m/s Speed 2.5 m/s 6.600 Speed 3.0 m/s Speed 3.0 m/s 3 5.560 (m2.5 /h)m/s) (Speed 2.5 m/s) 5.560 (m3/h) (Speed 9 9 Air Flow Air Flow /000 (m3/h)/000 (m3/h) 19.200 19.200 4 6 84 6 10 8 12 10 14 12 16 14 18 16 20 18 22 20 24 22 26 Air Flow Air Flow /000 (m3/h)/000 (m3/h) 136 24 28 26 30 28 32 30 34 32 34 DAIKIN AIR HANDLING UNITS D-AHU Easy UNIT FEATURES Panels Internal surface Hot injected Polyurethane panels to achieve excellent performance in terms of thermal insulation. Completely smooth internal surface. Special gaskets Optimized air face velocity Automatic dimensioning of section in order to guarantee an optimal air face velocity on coils and optimized unit cost. utilization of special gasket will ensure internal insulation of the profiles and will help to improve the thermal bridging factor. Unit competitiveness Construction The exclusive fixing method used for panels and profiles will ensure an uniform pressure on the whole profile length. That feature will improve significantly the air leakage rate. through Variable DimensioningTM exclusive design our clients are sure to invest only for the most optimized panel surface needed to match their requirements. 137 ERQ Air handling application (pair) A range of R-410A inverter condensing units for pair application with air handling units. ›› ›› ›› ›› ›› ›› Inverter controlled units Large capacity range (from 100 to 250 class) Heat pump R-410A Flexible control possibilities: - Control x: control of air temperature (discharge temperature, suction temperature, room temperature) via external device (DDC controller) - Control y: control of evaporating temperature via Daikin control (no DDC controller needed) - Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed) Wide range of expansion valve kits available Air handling unit Liquid pipe Liquid pipe Gas pipe Gas pipe Expansion valve kit : EKEXV gas pipe liquid pipe F1-F2 other communication Control box (cooling only): EKEQDCB : control z EKEQFCB : control x,y F1,F2 communication DDC controller (field supplied) control x COMBINATION TABLE Expansion valve kit Control box Outdoor unit 1~ 3~ ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1 control z control x or y class 63 class 80 class100 class 125 class 140 class 200 class 250 EKEQDCBA EKEQFCBA EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 P P P P P P P P P P P P P P P - P P P P - P P P P P - P P P P P P P P P P P P P P P P: Pair: Combination depending on air handling units coils volume. x: Possibility to connect. 138 Air handling unit Outdoor unit combined with indoor units Control box Outdoor units Capacity range Cooling capacity Heating capacity Power input Nom. Nom. Cooling Heating Nom. Nom. HeightxWidthxDepth Unit Unit Cooling Nom. Heating Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Heating Nom. Operation range Cooling Min./Max. Heating Min./Max. Refrigerant Type Piping Liquid OD connections Gas OD Drain OD Power supply Phase / Frequency / Voltage EER COP Dimensions Weight Fan-Air flow rate Expansion valve kit ERQ100AV1 4 11.2 12.5 ERQ140AV1 6 15.5 18.0 3.42 3.94 1,345x900x320 120 106 3.99 4.56 EER COP Dimensions Weight Fan-Air flow rate Outdoor units Capacity range Cooling capacity Heating capacity Power input HP kW kW kW kW Nom. Nom. Cooling Heating Nom. Nom. HeightxWidthxDepth Unit Unit Cooling Nom. Heating Nom. Sound power level Nom. Sound pressure Nom. level Operation range Cooling Min./Max. Heating Min./Max. Refrigerant Type Piping Liquid OD connections Gas OD Power supply Phase / Frequency / Voltage mm kg m³/min m³/min dBA dBA dBA °CDB °CWB mm mm mm Hz / V HP kW kW kW kW mm kg m³/min m³/min dBA dBA 102 66 50 52 ERQ125AV1 5 14.0 16.0 3.99 4.15 105 69 53 55 -5/46 -20/15.5 R-410A 9.52 19.1 26x3 1N~ / 50 / 220-440 15.9 ERQ125AW1 5 14.0 16.0 3.52 4.00 3.98 4.00 1,680x635x765 159 95 95 72 ERQ200AW1 8 22.4 25.0 5.22 5.56 4.29 4.50 54 57 °CDB °CWB mm mm Hz / V ERQ 139 15.9 ERQ250AW1 10 28.0 31.5 7.42 7.70 3.77 4.09 1,680x930x765 187 171 171 240 185 185 78 -5/43 -20/15 R-410A 9.52 19.1 3N~ / 50 / 400 15.9 67 51 53 58 22.2 measuring conditions CHILLERS Air cooled Cooling Water 7°C / 12°C Ambient temperature : 35°C Heating Water 45°C / 50°C Ambient temperature : 7°C Condensing unit Suction dewpoint : 5°C Condenserless chiller Cooling Water 7°C / 12°C Cooling Evaporator water : 7°C / 12°C Water condenser : 30°C / 35°C Heating Evaporator water : 7°C / 12°C Water condenser : 40°C / 45°C Water cooled Ambient temperature : 35°C Condensing temp : 45°C Liquid temp. : 40°C fan coils Measuring conditions (at nominal air flow and ESP): COOLING: air temperature entering the unit: 27°C/19°C, water temperature entering the unit 7°C, water temperature leaving the unit 12°C - HEATING: room air temperature 20°C, for 2-pipe units: water temperature entering 50°C - water flow rate same as for the cooling test, for 4-pipe units: water temperature entering 70°C - water temperature leaving 60°C 140 141 Notes 142 Notes 143 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com VRV® products are not within the scope of the Eurovent certification programme. Daikin products are distributed by: FSC ECPEN11-400_AFR Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende ECPEN11-400_AFR • CD • 03 /11 • Copyright Daikin The present publication supersedes ECPEN09-400. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.