Power Supply Unit Designed for Integration for Power Supply in Hazardous Areas WM-Ex For use in automated processes in ­hazardous environments (Zone 1; Class I, Div. 1). WMH-Ex For use in automated processes in ­hazardous environments (Zone 1, 21; Class I, II, III, Div. 1) – connectable ­without terminal. Modular Free places for additional slot cards to connect an additional interface at ACM200. Industrial Housing Is constructed of stainless steel and certified IP66. The housing will withstand harsh environments, and includes integrated mounting brackets to simplify installation. APS768x & ACM200 New solution for connecting WM-Ex & WMH-Ex in the hazardous area Customer benefits • Transmission distance between the weighing sensor and the data processor (PLC) has increased from 100 m to 400 m which ensures enhanced safety for the application. • The modular design allows being flexible and expandable not only to power the application terminal and the weighing platforms which have intrinsically safe outputs, but also to exchange data. Load Cells General Specifications APS768x-230V Mains connection Mains connection cable Cables (factory configuration) Maximum cable lengths IP protection type Temperature range Relative humidity Degree of pollution Overvoltage category Dimensions (L x W x H) Weight (incl. cables) Maximum altitude Sites of operation Number of attachable weighing sensors Available interface slots Hazardous area approvals 230 V +10 % / –15 %; 50 Hz; 0,160 A; Um ≤ 250 V 1,9 m; H 05 RN 5 m cable with 6 wires, intrinsically safe connection, M16x1,5 cable glands pre-assembled on both sides, longer cable is available if required (up to 100 m) WMH-Ex and WM-Ex to APS768x for direct connection 100 m. APS768x will be delivered without cable. It has to be ordered with the weighing sensor. IP66 –10 °C – +40 °C 20 % – 80 %, non-condensing 2 II 303 x 172 x 80 mm (without connectors) 320 x 172 x 80 mm (incl. connectors) 4,1 kg (net) Up to 4000 m height above sea level Indoor usage only 1 1: CL/CL interface can be added to the APS768x as an optional slot card to enable communication with the ACM200 communication module in the safe area. ATEX/IEC Ex: II 2G Ex e mb [ib] IIC T4 Gb-10 °C … +40 °C II 2D Ex t IIIC [ib] IP66 T70 °C FM: Class I, II, III Div. 1Group A-G / T4 Order Information APS768x Item Description APS768x Power supply unit in the hazardous area with attached power connection cable: 100, 120 and 230 V versions; 10 m ex-i cable with 9 wires for the connection with the weighing sensor Additional slot card (option) Longer Ex-Cable (option) Additional slot card with CL/CL interface to connect APS768x to ACM200; If this slot card is ordered, the 5 m ex-i cable with 6 wires for the connection with the weighing sensor is not delivered with APS768x, it has to be ordered with the weighing sensor 6 wire; up to max. 100 m; to connect APS768x with the weighing sensor Item number 120 V (USA) 230 V (Europe) 100 V (Japan) 22 023 337 00 504 638 22 021 261 22 021 262 22 021 263 General Specifications ACM200 AC power supply 100 V – 240V, 50 / 60 Hz Mains connection Mains connection cable Cables (factory configuration) Maximum cable lengths IP protection type Temperature range Relative humidity Degree of pollution Overvoltage category Dimensions (L x W x H) Weight (incl. cables) Maximum altitude Sites of operation Number of attachable power supplies Available interface slots Hazardous area approvals DC power supply 24 VDC Power connection cable has to be defined mains cord connected and provided by the end user. Claimed outer cable diameter is then 4 – 8 mm. 10 m cable with 4-wires for the connection with APS768x, intrinsically safe connection. APS768x to ACM200 for direct connection maximum 300 m. IP66 –10 °C – +40 °C 20 % – 80 %, non-condensing 2 II 175x160x69,5 mm 3,4 kg Up to 4000 m height above sea level Indoor usage only 1 1 intrinsically safe current loop interface for the communication with APS768x; RS232 data interface with mounted 10 m cable (9-pin SubD) as standard for the communication with a fieldbus or PLC; RS422 interface as option for the communication with a fieldbus or PLC, data cable has to be defined and provided by the end user. Claimed outer cable diameter is then 4 - 8 mm. ATEX/IEC Ex: II (2) G [Ex ib Gb] IIC –10 °C … +40 °C II (2) D [Ex ib Db] IIIC FM: AIS Class I, II, III Div. 1 Group A-G / T4 Order Information ACM200 Item ACM200-AC ACM200-DC Additional slot card (option) Longer Ex-Cable (Accessory) Description Communication module with an AC power supply Communication module with a DC power supply Additional slot card with a RS422 interface to connect to a fieldbus or PLC; If this slot card is installed, the standard RS232 interface becomes inaccessible. 100m cable with 4-wires for the connection with APS768x, intrinsically safe connection, 2 x 2 x 0,5qmm Item number 22 016 767 22 023 347 22 023 348 22 016 791 30 80 Dimensions APS768x-230 V (mm) 255 24 41 68 100 172 Ø10 284 303 320 Dimensions ACM200 (mm) 160 175 R3.5 R5 81 69.5 200 Mettler-Toledo AG CH-8606 Greifensee, Switzerland Tel. +41 44 944 22 11 Fax +41 44 944 30 60 Subject to technical changes MTSI 44098368 © 05/2012 Mettler-Toledo AG MarCom Industrial www.mt.com For more information