Transcript
Arc Chaser LW-AC120
21st Century Dual Mode TDR for Testing and Monitoring Energized Fault Finding/Cableand LengthUn-Energized Cables Measurement TDR
Accurately finds cable length, impediments in the cable and conditions at the end
of every wire in your data, power, or communications/video system up to 3,000 ft.
The Arc Chaser Dual Mode TDR is capable of finding faults (Opens, Shorts, Arc Faults) on fully energized
With the complexity of today’s electrical, voice and cables up to 600 Volts. Arcdata, Chaser can monitor live cables for intermittent conditions, capturing these video signal carrying systems, you need a tool
that is fast, accurate and easy to use to see down the wire and show “events” and reporting where and when they occur. Using advanced Spread Spectrum Time Domain the exact conditions that exist. FaultChaser is that tool. Made in America with (SSTDR) American technology, FaultChaser Reflectometry Arc Chaser is capable of accuracy to fault of better than 1%. is the new 21st century tool for testing every type of cable in any industry. Advanced Spread Spectrum TDR technology works in all wire environments and is immune to voltage, current, or data stream disruptions. See the • Works energized true picture of on your both wiring and cable systems or withnon-energized cables FaultChaser today. Discover cable events which can only be shown under load Features: ••Distance to fault accuracy of ±1% witharc known different tones Monitors intermittent faults,• 4opens and shorts VOP and consistent cable parameters • Works on energized cables Find faults caused by vibration that are otherwise hidden • Ability to measure length on live telephone lines • Large backlit LCD display • Memory storage for most used cables • Auto power-off
• Shows results in graphical or text format faults Test: Tests length, opens shorts present on the
Memory: Clear and simple view of Holds up to two different NVP values for multiple cable tests.
cable, up to 3,000 ft.
• Saves reports, transferrable to PCs for storage, Calibration: Tone Generation: and printing Ability to calibrate NVP for any cable. Produces four different tones for locating Maintain history of information cables. • Cable fault finding Easily verify quality of entire cable length • Tone generation Signal tracing of cables • Cable Test Setup Walks users through cable test setup • Self-calibrates to maintain accuracy over time or due to environmental change No metrology calibration required • English or Metric Measurements International applications • 600V Category III Meets full international requirements for working on energized cables. • Rechargeable Lithium-Ion Battery Pack 8-10 hours of battery power in the field
TM
Arc Chaser™ LW-AC120 Physical Features
Fault Detection
• Color Touch Screen Display Easy to navigate in all lighting environments • Compact Form Factor Usable in tight space environments
• 3rd Generation Rechargeable Lithium-Ion Batteries Graphical Text 8 to(12.0 10 oz.) hours continuous use Physical Dimensions: Size: 17.3 x 8.0 x 3.3 cm (6.8 x 3.15 x 1.3 inches) Weight: 340 grams With of battery
Technical Specifications
Input Protection: To 400 volts pead 50/60 Hz AC or DC • Benchtop, Handheld, or Hung Up Voltage Warning: At maximum of Safety Extra Low Voltage limits (60V peak AC or DC)
• Measurement continues while Easy to use for field flight line and production work warning is displayed. Live Intermittent Fault Detection Measurement Method: Spread Spectrum Time Domain Reflectometry (SSTDR) • Uses Modular Cable Interfaces NVP (VOP) Range: 20.0 to 99.9% Can connect to many different types of systems NVP Accuracy Range: ±1% with known NVP and consistent cable parameters Maximum Length: 3,000 ft. on cables with low attenuation • Waterproof/Shock Resistant Transport Case Common Cable Length Ranges: • Coaxial Cable - 0 to 2,000 feet Keeps equipment protected even in
• Data Cable - 0 to 1,500 feet harsh conditions
• Electrical Cable - 0 to 1,000 feet Tone Generation: 4 selectable tone cadences centered on 1 kHz • Constant output amplitude 3 Vp-p • SD of Card for Data File Transfer of Cable Tests Power: 4 AA alkaline batteries
• Standby: 4 years
• Active: 15 hours average Easy to maintain report files and save for Graphical Text Battery Low Level: Approximately 4 volts later viewing Operating Environment: • Operating temperature: 0 to 50°C (32 to 122°F) • Upgradeable Firmware • Storage temperature: -20 to 60°C (-4 to 140°F) Stay up to date with cable settings, features and • Humidity: 10% to 90%, non-condensing enhanced software upgrades. • Altitude: 3,050 meters (10,000ft) maximum Compliance:
Ordering
Complies with Conformité Européenne directives.
Specifications
KitPart Part Numbers &Description Accessories Number LWF-1001 LWF-1001-AD001 LWF-1001-AD002 LWF-1001-CA001 LW-AC120 LWF-1001-CA002 LWF-1001-CA003 LWF-1001-CP100
Arc Chaser main unit FaultChaser Livewire Leader Cable 5ft 1000Volt Cat III (Sheathed Banana Plug to Retractable Sheathed Banana F-connector Coupler Plug) BNC F-connector Crocodile Clips 600Volt Cat III Cable F Aviation to RJ45 adapters Dual Banana to BNC (F) adapter Cable BNC to Alligator (M) to F Connector (F) Cable F BNC to Alligator Power Supply HangingSD Pouch (Not Included) Card Micro USB Cable Protective Arc Chaser Case
Power
Wall Power voltage input Range: 10→28V, 20W (Arc Chaser will run with wall power down to 4V, however batteries will not charge unless input voltage is greater than 10V.) Totex Battery Pack, with four LIO Rechargeable Cells. Full Screen Brightness, Dynamic Test, 7.8V battery: 335mA. 0→100% brightness, @7.8V: 90mA Typical battery current: 185mA Low Power mode (or timed out): 70mA; Off mode: 420 µA board (+500uA Battery Pack circuitry.)
Battery Life
Battery Pack, initial 5200 mA-hr (typical): Operating at static screen, or occasional static test: 185mA (assuming 65% LCD brightness) Dynamic Operation : 280mA (assuming 65% LCD brightness) Low Power – 70mA, assuming full charge of 5000mAH, 71 hours. Off - 420 µA board (+500uA Battery Pack circuitry.)
Altitude
10,000 feet (3,050 meters)
Temperature
Operating: (-10 if standard crystal) -20 to 70°C); Storage: (-30 to 80°C)
Humidity
10 to 90% non-condensing
Enclosure
High-strength ABS plastic V0 with boot
Size
9.03” x 4.18” x 2.41”
Weight
With batteries: 1.9 lbs
Safety Compliances
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSAC22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, EMC EN61326-1
Optional Accessories Number KitPart Includes
Description
Protective Arc Chaser Case
TBD
Norsk importør:
LiveWire Innovation 575 E 4500 South #B-125 Salt Lake City, Utah 84107 USA
Tel: +1 801 293 8300 livewireinnovation.com
Eskeland Electronics AS Haugenvn. 10 1400 SKI Tlf: 64 94 30 70 Web: www.detektor.no