Preview only show first 10 pages with watermark. For full document please download

Architectural Elite 8 Electric Heated Air Curtain Data Sheet

   EMBED


Share

Transcript

ARCHITECTURAL ELITE 8 ™ Electric Heated Air Curtain Data Sheet For Door Heights To 8’ (environmental separation) STANDARD CONSTRUCTION • • • • • • • • • Open helical element with point suspension • Thermal overload protection • Galvanized steel frame • Alternate kW: see sheet EP-232 11” high x 24” deep 1/2 hp three speed motor(s) Factory provided remote fan speed/heat switch White powder coated exterior (Optional: Custom Color) Top Mounting (Wall optional) High efficiency, low noise Pro-V Nozzle Optional: Wall mounting plate Optional: Decorative adaptor 2 Year Limited Warranty Max Vel. Avg. Air Outlet Power at Nozzle Outlet Volume Vel. Rating (fpm) Vel. (fpm) (cfm) Uniformity (kW) Max Motor(s) Electric @ hp Capacity (kW) Heater Output (MBH) Air Temp. Net Wt. Rise (lbs) (°F) MODEL Nozzle Width (in) AEC08-1036E 36.50 3,255 1,680 1,115 79% 0.34 1@½ 9.0 30.7 25° 130 AEC08-1042E 42.50 3,354 1,557 1,249 71% 0.37 1@½ 9.0 30.7 23° 145 AEC08-1048E 48.50 2,958 1,838 1,685 78% 0.49 1@½ 12.0 41.0 22° 168 AEC08-1060E 59.50 3,168 1,697 1,912 71% 0.56 1@½ 12.0 41.0 20° 195 NOTE: 1. Operation at 50 Hz will generate approximately a 17% reduction in air performance. 2. Performance data based on AMCA licensed data from unheated units. See sheet EP-232 for amp draws/total load requirements and alternate kW. MODEL NUMBER CONFIGURATION AEC08-1 036 E B-CC Series AEC08 # of Motors 1 Opening Width Heat Voltage 036” - 60” E=Electric Heated *B = 208/1/60 *J = 240/1/60 *V = 220/1/50 K = 120/480 L = 120/600 S = 208/480 M= 208/600 U= 240/480 N= 240/600 X = 208/3/60 Y = 240/3/60 O = 380/3/50 *Max 16kW See sheet EP-232 for available lengths and voltages Opt. Cabinet Finish CC=Custom Color Sound level measured 10’ (3m) from the unit in free field: AEC1036 & AEC1042: Low/Medium/High Speed: 59/60/62 dBA AEC1048 & AEC1060: Low/Medium/High Speed: 61/62/64 dBA Berner reserves the right to alter specifications without prior notice. www.berner.com Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA 800.245.4455 DS-232 June, 2015 ©Copyright, 2015 Berner International Corporation ARCHITECTURAL ELITE 8 ™ Electric Heated Air Curtain Electrical Performance Sheet 240/1/60 (voltage code J) or MODEL AEC08-1036E AEC08-1042E AEC08-1048E AEC08-1060E MODEL AEC08-1036E AEC08-1042E AEC08-1048E AEC08-1060E 208/1/60 (voltage code B) 220/1/50 (voltage code V) 208/3/60 (voltage code X) 240/3/60 (voltage code Y) MOTOR AMP DRAW = 4.0 each MOTOR AMP DRAW = 4.0 each MOTOR AMP DRAW = 4.0 each MOTOR AMP DRAW = 4.0 each *kW option Temp Rise °F # CKTS AMPS PER CIRCUIT (including motor) BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT (including motor) BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT (including motor) BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT (including motor) BREAKER RATING PER CIRCUIT 9 25 1 47.3 60 1 41.5 60 1 29.0 40 1 25.7 35 6.8 19 1 36.7 50 1 32.3 45 1 22.9 30 1 20.4 30 5.1 14 1 28.5 40 1 25.3 35 1 18.2 25 1 16.3 25 4 11 1 23.2 30 - N/A N/A 1 15.1 20 - N/A N/A 12 23 2 23.2/38.5 30/50 2 20.7/33.3 30/45 1 37.3 50 1 32.9 45 9 17 1 47.3 60 1 41.5 60 1 29.0 40 1 25.7 35 6.8 13 1 36.7 50 1 32.3 45 1 22.9 30 1 20.4 30 5.1 10 1 28.5 40 1 25.3 35 1 18.2 25 1 16.3 25 *kW option Temp Rise °F # CKTS 9 25 6.8 120/1/60 - 480/3/60 (voltage code K) 208/1/60 - 480/3/60 (voltage code S) 240/1/60 - 480/3/60 (voltage code U) 380/3/50 (voltage code O) 120V MOTOR AMP DRAW = 7.2 each 208V MOTOR AMP DRAW = 4.0 each 240V MOTOR AMP DRAW = 4.0 each MOTOR AMP DRAW = 4.0 each AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT 120V/1 480V/3 120V/1 480V/3 2 7.2 10.8 15 15 19 2 7.2 8.2 15 5.1 14 - N/A N/A 4 11 - N/A 12 23 2 9 17 6.8 5.1 # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT # CKTS AMPS PER CIRCUIT (including motor) BREAKER RATING PER CIRCUIT 15 1 17.7 25 15 15 1 14.3 20 N/A N/A N/A 1 11.7 15 N/A N/A N/A N/A - N/A N/A 2 4.0 14.4 15 20 1 22.2 30 15 2 4.0 10.8 15 15 1 17.7 25 15 15 2 4.0 8.2 15 15 1 14.3 20 N/A N/A - N/A N/A N/A N/A 1 11.7 15 208V/1 480V/3 208V/1 480V/3 2 4.0 10.8 15 15 15 2 4.0 8.2 15 N/A N/A - N/A N/A N/A N/A N/A - N/A 7.2 14.4 15 20 2 2 7.2 10.8 15 15 13 2 7.2 8.2 15 10 - N/A N/A N/A # CKTS 240V/1 480V/3 240V/1 480V/3 2 4.0 10.8 15 15 2 4.0 8.2 N/A N/A - N/A N/A N/A N/A - 4.0 14.4 15 20 2 4.0 10.8 15 15 2 4.0 8.2 N/A - N/A N/A Page 1 of 2 Berner reserves the right to alter specifications without prior notice. www.berner.com Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA 800.245-4455 EP-232 June, 2015 ©Copyright, 2015 Berner International Corporation ARCHITECTURAL ELITE 8 ™ MODEL AEC08-1036E AEC08-1042E AEC08-1048E AEC08-1060E *kW option Temp Rise °F # CKTS 9 25 6.8 Electric Heated Air Curtain Electrical Performance Sheet 120/1/60 - 600/3/60 (voltage code L) 208/1/60 - 600/3/60 (voltage code M) 240/1/60 - 600/3/60 (voltage code N) 120V MOTOR AMP DRAW = 7.2 each 208V MOTOR AMP DRAW = 4.0 each 240V MOTOR AMP DRAW = 4.0 each AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT 120V/1 600V/3 120V/1 600V/3 2 7.2 8.7 15 15 19 - N/A N/A N/A 5.1 14 - N/A N/A 4 11 - N/A 12 23 2 9 17 6.8 5.1 # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT 208V/1 600V/3 208V/1 600V/3 2 4.0 8.7 15 15 N/A - N/A N/A N/A N/A N/A - N/A N/A N/A N/A N/A - N/A 7.2 11.5 15 15 2 2 7.2 8.7 15 15 13 - N/A N/A N/A 10 - N/A N/A N/A # CKTS AMPS PER CIRCUIT BREAKER RATING PER CIRCUIT 240V/1 600V/3 240V/1 600V/3 2 4.0 8.7 15 15 N/A - N/A N/A N/A N/A N/A N/A - N/A N/A N/A N/A N/A N/A N/A - N/A N/A N/A N/A 4.0 11.5 15 15 2 4.0 11.5 15 15 2 4.0 8.7 15 N/A 2 4 8.7 15 15 N/A - N/A N/A N/A N/A - N/A N/A N/A N/A N/A - N/A N/A N/A N/A - N/A N/A N/A N/A Page 2 of 2 Berner reserves the right to alter specifications without prior notice. www.berner.com Berner International Corporation 111 Progress Ave. / New Castle / PA / 16101 / USA 800.245-4455 EP-232 June, 2015 ©Copyright, 2015 Berner International Corporation