ARCHITECTURAL ELITE 8
™
Electric Heated Air Curtain Data Sheet
For Door Heights To 8’ (environmental separation) STANDARD CONSTRUCTION • • • • • • • •
• Open helical element with point suspension • Thermal overload protection • Galvanized steel frame • Alternate kW: see sheet EP-232
11” high x 24” deep 1/2 hp three speed motor(s) Factory provided remote fan speed/heat switch White powder coated exterior (Optional: Custom Color) Top Mounting (Wall optional) High efficiency, low noise Pro-V Nozzle Optional: Wall mounting plate Optional: Decorative adaptor
2 Year Limited Warranty
Max Vel. Avg. Air Outlet Power at Nozzle Outlet Volume Vel. Rating (fpm) Vel. (fpm) (cfm) Uniformity (kW)
Max Motor(s) Electric @ hp Capacity (kW)
Heater Output (MBH)
Air Temp. Net Wt. Rise (lbs) (°F)
MODEL
Nozzle Width (in)
AEC08-1036E
36.50
3,255
1,680
1,115
79%
0.34
1@½
9.0
30.7
25°
130
AEC08-1042E
42.50
3,354
1,557
1,249
71%
0.37
1@½
9.0
30.7
23°
145
AEC08-1048E
48.50
2,958
1,838
1,685
78%
0.49
1@½
12.0
41.0
22°
168
AEC08-1060E
59.50
3,168
1,697
1,912
71%
0.56
1@½
12.0
41.0
20°
195
NOTE: 1. Operation at 50 Hz will generate approximately a 17% reduction in air performance. 2. Performance data based on AMCA licensed data from unheated units. See sheet EP-232 for amp draws/total load requirements and alternate kW.
MODEL NUMBER CONFIGURATION
AEC08-1 036 E B-CC
Series
AEC08
# of Motors
1
Opening Width
Heat
Voltage
036” - 60”
E=Electric Heated
*B = 208/1/60 *J = 240/1/60 *V = 220/1/50 K = 120/480 L = 120/600 S = 208/480 M= 208/600 U= 240/480 N= 240/600 X = 208/3/60 Y = 240/3/60 O = 380/3/50 *Max 16kW See sheet EP-232 for available lengths and voltages
Opt. Cabinet Finish
CC=Custom Color
Sound level measured 10’ (3m) from the unit in free field: AEC1036 & AEC1042: Low/Medium/High Speed: 59/60/62 dBA AEC1048 & AEC1060: Low/Medium/High Speed: 61/62/64 dBA
Berner reserves the right to alter specifications without prior notice.
www.berner.com
Berner International Corporation
111 Progress Ave. / New Castle / PA / 16101 / USA
800.245.4455
DS-232 June, 2015
©Copyright, 2015 Berner International Corporation
ARCHITECTURAL ELITE 8
™
Electric Heated Air Curtain Electrical Performance Sheet
240/1/60 (voltage code J) or
MODEL
AEC08-1036E AEC08-1042E
AEC08-1048E AEC08-1060E
MODEL
AEC08-1036E AEC08-1042E
AEC08-1048E AEC08-1060E
208/1/60 (voltage code B)
220/1/50 (voltage code V)
208/3/60 (voltage code X)
240/3/60 (voltage code Y)
MOTOR AMP DRAW = 4.0 each
MOTOR AMP DRAW = 4.0 each
MOTOR AMP DRAW = 4.0 each
MOTOR AMP DRAW = 4.0 each
*kW option
Temp Rise °F
# CKTS
AMPS PER CIRCUIT (including motor)
BREAKER RATING PER CIRCUIT
# CKTS
AMPS PER CIRCUIT (including motor)
BREAKER RATING PER CIRCUIT
# CKTS
AMPS PER CIRCUIT (including motor)
BREAKER RATING PER CIRCUIT
# CKTS
AMPS PER CIRCUIT (including motor)
BREAKER RATING PER CIRCUIT
9
25
1
47.3
60
1
41.5
60
1
29.0
40
1
25.7
35
6.8
19
1
36.7
50
1
32.3
45
1
22.9
30
1
20.4
30
5.1
14
1
28.5
40
1
25.3
35
1
18.2
25
1
16.3
25
4
11
1
23.2
30
-
N/A
N/A
1
15.1
20
-
N/A
N/A
12
23
2
23.2/38.5
30/50
2
20.7/33.3
30/45
1
37.3
50
1
32.9
45
9
17
1
47.3
60
1
41.5
60
1
29.0
40
1
25.7
35
6.8
13
1
36.7
50
1
32.3
45
1
22.9
30
1
20.4
30
5.1
10
1
28.5
40
1
25.3
35
1
18.2
25
1
16.3
25
*kW option
Temp Rise °F
# CKTS
9
25
6.8
120/1/60 - 480/3/60 (voltage code K)
208/1/60 - 480/3/60 (voltage code S)
240/1/60 - 480/3/60 (voltage code U)
380/3/50 (voltage code O)
120V MOTOR AMP DRAW = 7.2 each
208V MOTOR AMP DRAW = 4.0 each
240V MOTOR AMP DRAW = 4.0 each
MOTOR AMP DRAW = 4.0 each
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
120V/1
480V/3
120V/1
480V/3
2
7.2
10.8
15
15
19
2
7.2
8.2
15
5.1
14
-
N/A
N/A
4
11
-
N/A
12
23
2
9
17
6.8 5.1
# CKTS
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
# CKTS
AMPS PER CIRCUIT (including motor)
BREAKER RATING PER CIRCUIT
15
1
17.7
25
15
15
1
14.3
20
N/A
N/A
N/A
1
11.7
15
N/A
N/A
N/A
N/A
-
N/A
N/A
2
4.0
14.4
15
20
1
22.2
30
15
2
4.0
10.8
15
15
1
17.7
25
15
15
2
4.0
8.2
15
15
1
14.3
20
N/A
N/A
-
N/A
N/A
N/A
N/A
1
11.7
15
208V/1
480V/3
208V/1
480V/3
2
4.0
10.8
15
15
15
2
4.0
8.2
15
N/A
N/A
-
N/A
N/A
N/A
N/A
N/A
-
N/A
7.2
14.4
15
20
2
2
7.2
10.8
15
15
13
2
7.2
8.2
15
10
-
N/A
N/A
N/A
# CKTS
240V/1
480V/3
240V/1
480V/3
2
4.0
10.8
15
15
2
4.0
8.2
N/A
N/A
-
N/A
N/A
N/A
N/A
-
4.0
14.4
15
20
2
4.0
10.8
15
15
2
4.0
8.2
N/A
-
N/A
N/A
Page 1 of 2
Berner reserves the right to alter specifications without prior notice.
www.berner.com
Berner International Corporation
111 Progress Ave. / New Castle / PA / 16101 / USA
800.245-4455
EP-232 June, 2015 ©Copyright, 2015 Berner International Corporation
ARCHITECTURAL ELITE 8
™
MODEL
AEC08-1036E AEC08-1042E
AEC08-1048E AEC08-1060E
*kW option
Temp Rise °F
# CKTS
9
25
6.8
Electric Heated Air Curtain Electrical Performance Sheet
120/1/60 - 600/3/60 (voltage code L)
208/1/60 - 600/3/60 (voltage code M)
240/1/60 - 600/3/60 (voltage code N)
120V MOTOR AMP DRAW = 7.2 each
208V MOTOR AMP DRAW = 4.0 each
240V MOTOR AMP DRAW = 4.0 each
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
120V/1
600V/3
120V/1
600V/3
2
7.2
8.7
15
15
19
-
N/A
N/A
N/A
5.1
14
-
N/A
N/A
4
11
-
N/A
12
23
2
9
17
6.8 5.1
# CKTS
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
208V/1
600V/3
208V/1
600V/3
2
4.0
8.7
15
15
N/A
-
N/A
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
N/A
-
N/A
7.2
11.5
15
15
2
2
7.2
8.7
15
15
13
-
N/A
N/A
N/A
10
-
N/A
N/A
N/A
# CKTS
AMPS PER CIRCUIT
BREAKER RATING PER CIRCUIT
240V/1
600V/3
240V/1
600V/3
2
4.0
8.7
15
15
N/A
-
N/A
N/A
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
4.0
11.5
15
15
2
4.0
11.5
15
15
2
4.0
8.7
15
N/A
2
4
8.7
15
15
N/A
-
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
-
N/A
N/A
N/A
N/A
Page 2 of 2 Berner reserves the right to alter specifications without prior notice.
www.berner.com
Berner International Corporation
111 Progress Ave. / New Castle / PA / 16101 / USA
800.245-4455
EP-232 June, 2015 ©Copyright, 2015 Berner International Corporation