Transcript
ARCO A
AXIAL EXTRACT FAN
PRODUCT INFORMATION
ARCO A
AXIAL EXTRACT FAN
SPECIFICATION
Features / benefits
Casing The ABS fan casing provides a long lasting shockproof and robust construction. The units are finished in white RAL 9010 and are UV resistant.
IPX4 Splashproof, suitable for installation in Zones 1 and 2.
Motors Shaded pole induction type with integral fuse protection, mounted on sealed for life ball bearings. All fans are double insulated.
Automatic Shutter Silent operating front fascia automatic shutter powered by Thermo Actuator for air tightness. Unique Impeller Design BLADELET impeller for optimised flow rate and performance.
Impellers BLADELET impellers are provided with blades made from high quality reinforced polypropylene providing enhanced aerodynamic properties, low noise and increased efficiency.
Double Insulated No earth connections required.
Quality Management All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008.
Rigidity Optimised spigot support preventing distortion with strengthened guard and design to maximise airflow.
Totally Recyclable Plastic Components Environmentally friendly.
Reliability Capacitor type PCB power supply reducing PCB heat dissipation. Sealed for life ball bearings for increased motor life and cold climates.
applications & MODEL VERSIONS Model
Location
M
C
T
HT
HTC
ARCO A 100
Bathroom
∞
∞
∞
∞
∞
ARCO A 125
Utility
∞
∞
∞
∞
∞
ARCO A 150
Kitchen
∞
∞
∞
∞
∞
Tested to the Latest Standards Units are tested to EN 13141-4 (performance) and to BS 848 Pt 2:1985 (sound performance) at Elta Fans own test facility, meaning accurate, up to date information on performance and noise data that can be relied upon. Designed and manufactured in accordance with EN 60335-1, EN 60335-2-80 (electrical safety), EN 61000-3-3, EN 61000-3-2, EN 55014-1, EN 55014-2 (electromagnetic compatibility) and independently tested and certified by TÜV Rheinland. Warranty Each ARCO A has a THREE year warranty as standard.
M-Manual, C-Pull cord, T-Run on timer, HT-Humidistat/Timer, HTC-Humidistat/Cord/Timer.
PERFORMANCE DATA Model
Air flow L/s max
Power W max
SFP
Sound Pressure dB(A) @3m
Ambient Temperature °C max
ARCO A 100
21.5
11
0.49
33
50
ARCO A 125
41.9
16
0.35
38
50
ARCO A 150
88.1
26
0.28
43
50
220-240V. 50-60Hz. Air performance measured according to ISO 5801. All data measured in our TÜV Rheinland accredited laboratory.
A
DIMENSIONAL DATA
C
øB
D
Model
A
B
C
D
ARCO A 100
164
99
70
29
ARCO A 125
184
119
81
30
ARCO A 150
218
148
97
32
Dimensions in mm
PERFORMANCE CURVES ARCO A 100
ARCO A 125
30
ARCO A 150 60
45
40
25
50 35
40
15
10
Static Pressure - Pa
30
Static Pressure - Pa
Static Pressure - Pa
20
25
20
15
30
20
10
5
10 5
0
0
5
10
15
20
25
Volume L/s
0
0
5
10
15
20
25
30
35
40
45
0
0
20
Volume L/s
ARCO A 100
ARCO A 125
ARCO A 150
CONTROLS
External Fixed Grille
410-GE100
410-GE125
410-GE150
PIR Sensor
410-WKG100
410-WKG125
410-WKG 150
Ceiling Mount Kit
410-CG100
410-CG125
410-CG150
1A Control
350mm Tube
410-EKC242
410-EKC266
410-EKC660
Timer
3m Flexible Aluminium Duct Jubilee Clip
410-EA3M2PLY102 410-EA3M2PLY127 410-EKC264
410-EKC611
60
80
100
Volume L/s
ACCESSORIES Window Kit with External Fixed Grille
40
410-EA3M2PLY152 410-EKC674
Tamperproof Humidistat
Humidistat with Timer
149-SEN-PIR 149-HS2 149-SEN-REL1A 149-SEN-T 149-SEN-HY
TEL: +44 (0) 1384 275803, FAX: +44 (0) 1384 275810, E-MAIL:
[email protected] 46 THIRD AVENUE, PENSNETT TRADING ESTATE, KINGSWINFORD, WEST MIDLANDS, DY6 7US, UK WWW.homevent.co.uk Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.
EFR. ARCO A. 24.02.15.
A member of