Preview only show first 10 pages with watermark. For full document please download

Arena Symphony

   EMBED


Share

Transcript

Arena Symphony AS149ZSB / 96239258 ARENA S T16 1X49 HF WL6 DSB 850 Times New Roman G5 49W T16 Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 1 x 49W T16 lamp(s). Electronic, fixed output control gear. Body: steel, white (close to RAL 9010). louvre: perforated highly reflective satinbrite aluminium. Electrical connection via 6 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 95 mm Total power: 52.2 W Weight: 22 kg TLG_ARNS_F_DSBLOUVRE.jpg 180° 150° 150° 120° 90° 120° 300 200 100 90° 60° 60° 30° cd/klm 30° 0° TLG_SP_0040665.ldt Lamp position: STD - standard Lamps: 1 x T16 / 49W Total luminous flux: 4300 lm Luminaire efficacy: 69 lm/W Colour Rendering Index min.: 80 LOR: 0,84 ULOR: 0,24 DLOR: 0,60 Lamp efficacy: 82 lm/W Ballast: 1x HF_ Tridonic PC T5 PRO LP Connected Load: 52.2 W Lambda = 0.98 Dimming: Fixed output CELMA EEI: A2 BAT Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting Arena Symphony AS149ZSB / 96239258 ARENA S T16 1X49 HF WL6 DSB 850 Times New Roman 180° 150° 150° 120° 90° 0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180° 120° 300 200 100 90° 60° 60° 30° 30° cd/klm C180 | C0 C270 | C90 0° Light output ratio Glare Evaluation C0 267 272 293 320 342 347 323 274 208 131 76 34 7 2 1 0 0 0 0 2 2 2 2 3 6 15 27 41 57 69 85 99 110 116 117 117 118 C90 C180 C270 267 267 267 265 272 265 262 293 262 255 320 255 244 342 244 234 347 234 217 323 217 200 274 200 183 208 183 155 131 155 117 76 117 61 34 61 19 7 19 1 2 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 3 2 3 11 2 11 19 2 19 27 2 27 38 3 38 48 6 48 57 15 57 66 27 66 75 41 75 85 57 85 91 69 91 99 85 99 104 99 104 108 110 108 113 116 113 116 117 116 117 117 117 118 118 118 Classification LOR 84 % X= 4 H, Y= 8 H ULOR 24 % Reflection factors 70/50/20 EN 65°<1000cd/m² DLOR 60 % UGR transversal <13 BZ BZ1 UGR axial <13 UTE FFR 0.40 (29:71) BLF 1.00 S = 1.00 H LiTG B63 0.60 B + 0.24 T CIE Flux Codes 72 99 100 71 84 Utilization Factors Room Reflectance Ceiling/Walls/Floor 0.75 1.00 1.25 1.50 Room Index 2.00 2.50 3.00 4.00 5.00 70 / 50 / 20 56 62 67 70 74 77 79 81 83 70 / 30 / 20 51 58 62 66 71 74 76 79 81 70 / 10 / 20 48 54 59 63 68 71 73 77 79 50 / 50 / 20 52 58 62 64 68 70 72 74 75 50 / 30 / 20 49 54 58 61 65 68 70 72 73 50 / 10 / 20 46 52 56 59 63 66 68 70 72 30 / 50 / 20 49 54 57 59 62 64 65 67 68 30 / 30 / 20 46 51 55 57 60 62 64 65 67 30 / 10 / 20 44 49 53 55 59 61 63 64 66 0/ 0/ 0 40 45 48 50 52 54 55 56 57 According to CIBSE Technical Memorandum No. 5 1980 SHR Nom = SHR Max = SHR Max TR = 1.50 1.70 1.83 Photometric data file: TLG_SP_0040665.ldt Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting