Transcript
Arena Symphony AS149ZSB / 96239258 ARENA S T16 1X49 HF WL6 DSB 850 Times New Roman G5
49W T16
Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 1 x 49W T16 lamp(s). Electronic, fixed output control gear. Body: steel, white (close to RAL 9010). louvre: perforated highly reflective satinbrite aluminium. Electrical connection via 6 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 95 mm Total power: 52.2 W Weight: 22 kg
TLG_ARNS_F_DSBLOUVRE.jpg
180° 150°
150°
120°
90°
120°
300
200
100
90°
60°
60°
30° cd/klm
30° 0° TLG_SP_0040665.ldt
Lamp position: STD - standard Lamps: 1 x T16 / 49W Total luminous flux: 4300 lm Luminaire efficacy: 69 lm/W Colour Rendering Index min.: 80 LOR: 0,84 ULOR: 0,24 DLOR: 0,60
Lamp efficacy: 82 lm/W Ballast: 1x HF_ Tridonic PC T5 PRO LP Connected Load: 52.2 W Lambda = 0.98 Dimming: Fixed output CELMA EEI: A2 BAT
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting
Arena Symphony AS149ZSB / 96239258 ARENA S T16 1X49 HF WL6 DSB 850 Times New Roman
180° 150°
150°
120°
90°
0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180°
120°
300
200
100
90°
60°
60°
30°
30°
cd/klm
C180 | C0 C270 | C90
0°
Light output ratio
Glare Evaluation
C0 267 272 293 320 342 347 323 274 208 131 76 34 7 2 1 0 0 0 0 2 2 2 2 3 6 15 27 41 57 69 85 99 110 116 117 117 118
C90 C180 C270 267 267 267 265 272 265 262 293 262 255 320 255 244 342 244 234 347 234 217 323 217 200 274 200 183 208 183 155 131 155 117 76 117 61 34 61 19 7 19 1 2 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 3 2 3 11 2 11 19 2 19 27 2 27 38 3 38 48 6 48 57 15 57 66 27 66 75 41 75 85 57 85 91 69 91 99 85 99 104 99 104 108 110 108 113 116 113 116 117 116 117 117 117 118 118 118
Classification
LOR
84 %
X= 4 H, Y= 8 H
ULOR
24 %
Reflection factors
70/50/20
EN
65°<1000cd/m²
DLOR
60 %
UGR transversal
<13
BZ
BZ1
UGR axial
<13
UTE
FFR
0.40 (29:71)
BLF
1.00
S = 1.00 H
LiTG
B63
0.60 B + 0.24 T
CIE Flux Codes
72 99 100 71 84
Utilization Factors Room Reflectance Ceiling/Walls/Floor
0.75
1.00
1.25
1.50
Room Index 2.00
2.50
3.00
4.00
5.00
70 / 50 / 20
56
62
67
70
74
77
79
81
83
70 / 30 / 20
51
58
62
66
71
74
76
79
81
70 / 10 / 20
48
54
59
63
68
71
73
77
79
50 / 50 / 20
52
58
62
64
68
70
72
74
75
50 / 30 / 20
49
54
58
61
65
68
70
72
73
50 / 10 / 20
46
52
56
59
63
66
68
70
72
30 / 50 / 20
49
54
57
59
62
64
65
67
68
30 / 30 / 20
46
51
55
57
60
62
64
65
67
30 / 10 / 20
44
49
53
55
59
61
63
64
66
0/ 0/ 0
40
45
48
50
52
54
55
56
57
According to CIBSE Technical Memorandum No. 5 1980
SHR Nom = SHR Max = SHR Max TR =
1.50 1.70 1.83
Photometric data file: TLG_SP_0040665.ldt
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting