Arena Symphony AS235ZPC / 96239263 ARENA S T16 2X35 HF WL6 EDP PC 850 Times New Roman G5
35W T16
Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 2 x 35W T16 lamp(s). Electronic, fixed output control gear. Body: steel, white (close to RAL 9010). diffuser: reeded curved polycarbonate. Electrical connection via 4 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 135 mm Total power: 76 W Weight: 22 kg Luminaire efficacy: 72 lm/W
TLG_ARNS_F_CURVEDDIF.jpg
180° 150°
150°
120°
90°
120°
180
120
60
90°
60°
60°
30° cd/klm
30° 0° TLG_SP_0039116.ldt
Lamp position: STD - standard Lamps: 2 x T16 / 35W Total luminous flux: 6600 lm Luminaire efficacy: 72 lm/W Colour Rendering Index min.: 80 LOR: 0,83 ULOR: 0,25 DLOR: 0,58
Lamp efficacy: 87 lm/W Ballast: 1x HF_ HF-S Connected Load: 76 W Lambda = 0.95 Dimming: Fixed output CELMA EEI: A2
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting
Arena Symphony AS235ZPC / 96239263 ARENA S T16 2X35 HF WL6 EDP PC 850 Times New Roman
180° 150°
150°
120°
90°
0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180°
120°
180
120
60
90°
60°
60°
30°
30°
cd/klm
C180 | C0 C270 | C90
0°
Light output ratio
Glare Evaluation
C0 183 185 192 196 203 215 215 199 170 146 129 100 75 55 44 38 35 34 31 2 2 2 2 4 6 18 33 48 66 84 91 93 100 106 107 107 106
C90 C180 C270 183 183 183 182 185 182 179 192 179 176 196 176 169 203 169 162 215 162 152 215 152 139 199 139 124 170 124 107 146 107 88 129 88 67 100 67 47 75 47 31 55 31 19 44 19 12 38 12 7 35 7 4 34 4 2 31 2 4 2 4 12 2 12 21 2 21 31 2 31 40 4 40 49 6 49 58 18 58 66 33 66 73 48 73 80 66 80 86 84 86 92 91 92 97 93 97 100 100 100 103 106 103 104 107 104 106 107 106 106 106 106
Classification
LOR
83 %
X= 4 H, Y= 8 H
ULOR
25 %
Reflection factors
70/50/20
EN
DLOR
58 %
UGR transversal
<19
BZ
UGR axial
<19
UTE
0.58 D + 0.25 T
CIE Flux Codes
49 79 93 70 83
FFR
0.43 (30:70)
BLF
1.00
S = 1.00 H
LiTG
B43
BZ3/1.25/BZ4
Utilization Factors Room Reflectance Ceiling/Walls/Floor
0.75
1.00
1.25
1.50
Room Index 2.00
2.50
3.00
4.00
5.00
70 / 50 / 20
NA
52
57
61
66
70
72
75
77
70 / 30 / 20
NA
47
52
56
62
65
68
72
75
70 / 10 / 20
NA
43
48
52
58
62
65
69
72
50 / 50 / 20
NA
48
52
56
60
63
65
68
69
50 / 30 / 20
NA
44
48
51
56
60
62
65
67
50 / 10 / 20
NA
40
45
48
53
57
59
63
65
30 / 50 / 20
NA
44
48
50
54
57
59
61
62
30 / 30 / 20
NA
40
44
47
51
54
56
59
61
30 / 10 / 20
NA
37
41
45
49
52
54
57
59
0/ 0/ 0
NA
33
36
39
42
44
46
48
50
According to CIBSE Technical Memorandum No. 5 1980
SHR Nom = SHR Max = SHR Max TR =
1.75 1.78 2.07
Photometric data file: TLG_SP_0039116.ldt
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting