Arena Symphony

   EMBED


Share

Transcript

Arena Symphony AS235ZPC / 96239263 ARENA S T16 2X35 HF WL6 EDP PC 850 Times New Roman G5 35W T16 Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 2 x 35W T16 lamp(s). Electronic, fixed output control gear. Body: steel, white (close to RAL 9010). diffuser: reeded curved polycarbonate. Electrical connection via 4 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 135 mm Total power: 76 W Weight: 22 kg Luminaire efficacy: 72 lm/W TLG_ARNS_F_CURVEDDIF.jpg 180° 150° 150° 120° 90° 120° 180 120 60 90° 60° 60° 30° cd/klm 30° 0° TLG_SP_0039116.ldt Lamp position: STD - standard Lamps: 2 x T16 / 35W Total luminous flux: 6600 lm Luminaire efficacy: 72 lm/W Colour Rendering Index min.: 80 LOR: 0,83 ULOR: 0,25 DLOR: 0,58 Lamp efficacy: 87 lm/W Ballast: 1x HF_ HF-S Connected Load: 76 W Lambda = 0.95 Dimming: Fixed output CELMA EEI: A2 Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting Arena Symphony AS235ZPC / 96239263 ARENA S T16 2X35 HF WL6 EDP PC 850 Times New Roman 180° 150° 150° 120° 90° 0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180° 120° 180 120 60 90° 60° 60° 30° 30° cd/klm C180 | C0 C270 | C90 0° Light output ratio Glare Evaluation C0 183 185 192 196 203 215 215 199 170 146 129 100 75 55 44 38 35 34 31 2 2 2 2 4 6 18 33 48 66 84 91 93 100 106 107 107 106 C90 C180 C270 183 183 183 182 185 182 179 192 179 176 196 176 169 203 169 162 215 162 152 215 152 139 199 139 124 170 124 107 146 107 88 129 88 67 100 67 47 75 47 31 55 31 19 44 19 12 38 12 7 35 7 4 34 4 2 31 2 4 2 4 12 2 12 21 2 21 31 2 31 40 4 40 49 6 49 58 18 58 66 33 66 73 48 73 80 66 80 86 84 86 92 91 92 97 93 97 100 100 100 103 106 103 104 107 104 106 107 106 106 106 106 Classification LOR 83 % X= 4 H, Y= 8 H ULOR 25 % Reflection factors 70/50/20 EN DLOR 58 % UGR transversal <19 BZ UGR axial <19 UTE 0.58 D + 0.25 T CIE Flux Codes 49 79 93 70 83 FFR 0.43 (30:70) BLF 1.00 S = 1.00 H LiTG B43 BZ3/1.25/BZ4 Utilization Factors Room Reflectance Ceiling/Walls/Floor 0.75 1.00 1.25 1.50 Room Index 2.00 2.50 3.00 4.00 5.00 70 / 50 / 20 NA 52 57 61 66 70 72 75 77 70 / 30 / 20 NA 47 52 56 62 65 68 72 75 70 / 10 / 20 NA 43 48 52 58 62 65 69 72 50 / 50 / 20 NA 48 52 56 60 63 65 68 69 50 / 30 / 20 NA 44 48 51 56 60 62 65 67 50 / 10 / 20 NA 40 45 48 53 57 59 63 65 30 / 50 / 20 NA 44 48 50 54 57 59 61 62 30 / 30 / 20 NA 40 44 47 51 54 56 59 61 30 / 10 / 20 NA 37 41 45 49 52 54 57 59 0/ 0/ 0 NA 33 36 39 42 44 46 48 50 According to CIBSE Technical Memorandum No. 5 1980 SHR Nom = SHR Max = SHR Max TR = 1.75 1.78 2.07 Photometric data file: TLG_SP_0039116.ldt Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting