Preview only show first 10 pages with watermark. For full document please download

Asb 100

   EMBED


Share

Transcript

ACTIVE 4 - WAY SPLITTER ASB 100 SAT IF, LNC voltage bypass PRODUCT VARIANTS BLINE LED - “remote supply” ASB 100 9060.02 Active SAT IF splitter [950 … 2150 MHz] LNC SUPPLY SAT - IF IN SAT - IF Input Attenuation switch GAIN TEST OUT -15 dB Test output (-15 dB) ACTIVE 4 - WAY SPLITTER LNC REMOTE SUPPLY MODEL: ASB 100 ART.-No.:9060.02 SAT-IF-IN / OUT 950 … 2150 MHz GAIN 2 dB MAX. OUTPUT LEVEL (2 CH) 97 dBµV MAX. LNC SUPPLY 12 V / 0,4 A MAX. SUPPLY CURRENT (OUT OF LNC) 0,15 A Operating voltage control bus X1 GENERAL X2 The active SAT IF splitter ASB 100 is a module of the head end system B - Line, which is conceived as a complete system for middle sized distribution networks. SAT - IF OUT 1 EXT. LNC SUPPLY IN The module distributes a SAT - IF signal without level loss to the four outputs. OUT 2 The LNC remote supply voltage can be supplied internal or external via a "bypass". SAT IF output OUT 3 OUT 4 Fig. 01 FUNCTION DESCRIPTION A "bypass" is arranged at the SAT - IF input of the module to switch the LNC supply voltage to the input socket. With help of the jumper, the internal 12 V supply voltage of the module, or an external voltage, supplied over the output socket “OUT 1” (for example 13 / 15 / 17 V from a passive distributor PSB 100), can be selected. If the remote supply is active, a green LED next to the input socket is lit up. The remote supply can be deactivated. The electronic loss adjuster makes the adjustment of the optimal input level of the following processing units possible. With a directional coupler the input signal is uncoupled onto a test socket (-15 dB). The frequency response is compensated with a firm, internal equalizer. A two stage amplifier adjusts the splitter attenuation of the output four-way splitter. Additional information: Block diagram Conversion of the LNC supply voltage (Fig. 02) (Fig. 03) BLOCK DIAGRAM 5 4 1 Input Test output Output dB 3 2 + 12 V Fig. 02 TECHNICAL DATA RF parameter Frequency range Connector Impedance Amplification 950 ... 2.150 MHz F socket 75 W W 0 dB 2 dB 15 dB 950 MHz 2150 MHz Decoupling attenuation test point Max. output level at 2 - carrier - IMA = 35 dB Level adjustment range 97 dBµV - 10 dB Operating parameter Voltage / current Residual ripple of the supply voltage 12 V (±0,2 V) / 150 mA 10 mVss Environmental conditions Temperature range Relative humidity Mounting method Mounting location -10 ... +55 °C £ 80 % (not condensing) vertical squirting and dripping water protected Physical information Dimensions (l x w x h) without 19” - adapter with 19” - adapter Weight 50 x 276 x 148 mm 50 x 301 x 148 mm 1.156 g Delivery contents 1 x BUS connector CONVERSION OF THE LNC REMOTE SUPPLY Reference: To change the adjustments by the factory, the front cover has to be removed (pull to the front)! LED Input socket Attenuation switch Test output Ext. 12 V Ext. Ext. Aus No remote supply 12 V Aus Internal supply through 12 V operating voltage (factory setting) Jumper 12 V Aus External supply (the voltage must be applied at “OUT 1”) Fig. 03 SECURITY AND OPERATING INSTRUCTIONS When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in the instruction manual! The modules may only be installed and started up by authorized technical personnel! When assembling the modules into the receiving points, the adherence of the EMV regulations is to be secured! The assembly and wiring have to be done without voltage! All active modules may only be operated with the head end controller HCB 100 or bus extender BEB 100! The main voltage for all power supply units is 230 V, 50 Hz. With all work the defaults of the DIN EN 50083 have to be considered! Especially the safety relevant execution of the DIN EN 50083/1 is necessary! Part - No.: 9060.02 BLANKOM Antennentechnik GmbH Hermann - Petersilge - Str. 1 · 07422 Bad Blankenburg · Germany · Phone +49 (0) 36741/ 60-0 · Fax +49 (0) 36741/ 60-100