Transcript
REVISIONS NOTES: 1
THESE SIGNALS NOT AVAILABLE
ON 2015333-XXX/2100204-001 (CB195) & 2102838-XXX (XFC G4)
NOT CONNECTED ON RS485
3
SEE SH 2
4
SEE SH 4 & 7
5
SEE SH 4 & 7
6
SEE SH 4 & 7
7
SEE SH 4 & 7
8
GLOSSARY OF TERMS
9
SEE SH 4 & 7
ACTION
DRAWN
CHECKED
APPROVED
DATE
AK
D10240
KASTNER
KASTNER
HOLLAND
00/09/08
AL
D11820
KASTNER
KASTNER
HOLLAND
01/09/07
AM
D20706
KASTNER
KASTNER
BUSHNELL
07/08/22
FCU MODEL 6410/6411/6413/6414
UNLESS COMM MODULE IS USED. 2
REV
J4 GND
1
VBATT
2
SWVBATT
3
TXD(+)
4
TXD(-)
5
RXD(+)
6
RXD(-)
7
RTS
8
CTS
9
DTR
10
CD
11
TXAO
12
RXAO
13
RTSO
14
CTSO
15
OPER
16
NOT CONNECTED ON RS232
NOT CONNECTED ON RS232
2
1
2
ITEM
ASSEMBLY/QUANTITY DO
NOT
SCALE
DRAWING
UNLESS
OTHERWISE
DIMENSIONS THIRD ANGLE PROJECTION
PART
NO. ARE
TOLERANCES
IN
BREAK
DESIGN
ALL
DIMENSIONS
G.
ANGULAR
B.
R
HOLLAND
3 94/12/05
ROBERTSON 94/12/02
CHECKED
WIDENER APPLY
CORNERS BEFORE
AND FINISH
EDGES
APPROVED
G.
HOLLAND
UNIT MEAS
LEVEL
---
SHARP
MATERIAL
TOTALFLOW Products
DATE
DRAWN
--
--
.XXX
LINE
TOTALFLOW
INCHES
ARE:
DECIMAL .XX
PRODUCT
SPECIFIED
REF/ZONE DESIG
DESCRIPTION
NUMBER
94/12/15 94/12/05
TITLE
WIRING INTERCONNECT
RS485/RS232 FOR FCU (64XX/67XX), RTU (6490/6790/6890) WI
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING
NO.
REV
2015225 AM
SHEET
1
OF
15
3
COMM MODULE CANNOT BE USED IN REMOTE COMM 1 IF A RS232 OR RS485 TYPE CARD
IS USED IN I/O INTERFACE OPTION.
FCU MODEL 6713/6714 (CB181 PCBA) REMOTE COMM 1 MODULE
REMOTE COMM 2
3 CARD
REMOTE COMM 3
MODULE
MODULE
J4
RS232
RS485
RS232
RS485
J5
RS232
RS485
J6
RS232
RS485
1
VBATT
VBATT
VBATT
VBATT
1
VBATT
VBATT
1
VBATT
VBATT
2
GND
GND
GND
GND
2
GND
GND
2
GND
GND
3
SWVBAT
SWVBAT
SWVBAT
SWVBAT
3
SWVBAT
SWVBAT
3
SWVBAT
SWVBAT
4
TXD
BUS(+)
TXD
TRM(-)
4
TXD
BUS(+)
4
TXD
BUS(+)
BUS(+)
5
BUS(-)
6
BUS(-)
7
RRTS
8
RTS
BUS(+)
5
6
RXD
BUS(-)
5
BUS(-)
6
TRM(+)
7
RTS
BUS(+)
8
RTS
RXD
BUS(-)
7
8
RTS
RRTS
RXD
BUS(+) BUS(-)
9
CTS
CTS
AO(-)
9
CTS
9
CTS
10
DTR
DTR
RRTS
10
DTR
10
DTR
11
DCD
DCD
AO(+)
11
DCD
11
DCD
12
OPER
OPER
OPER
12
OPER
12
OPER
13
GND
13
GND
13
GND
OPER
OPER
BUS(-)
RXD
SCALE
NONE
RRTS
OPER
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
2
OF
RTU195 PCBA (2100355-XXX) 2103022-XXX (XRC G4) REMOTE COMM 1
REMOTE COMM 2
MODULE
MODULE
J6
RS232
RS485
J6
RS232
RS485
1A
VBATT
VBATT
1B
VBATT
VBATT
2A
GND
GND
2B
GND
GND
3A
SWVBAT
SWVBAT
3B
SWVBAT
SWVBAT
4A
OPER
OPER
4B
OPER
OPER
5A
RTS
RRTS
5B
RTS
RRTS
6A
DCD
BUS(-)
6B
DCD
BUS(-)
7A
RXD/
BUS(-)
7B
RXD/
BUS(-)
8A
CTS/
BUS(+)
8B
CTS/
BUS(+)
9A
TXD/
BUS(+)
9B
TXD/
BUS(+)
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
3
OF
OPTIONAL EQUIPMENT RS485 SPECIFICATIONS: 4
ALL FCU OF SAME MODEL ARE WIRED IDENTICAL EXCEPT THE LAST FCU.
5
66XX FCU's AND 64XX FCU's MAY BE MIXED TOGETHER.
6
MAX NUMBER OF LOADS THAT MAY BE CONNECTED IN SERIES IN THIS SITUATION USING RS485 COMMUNICATION IS 10.
7
TOTAL LENGTH OF RS485 CABLE IN THIS SITUATION NOT TO EXCEED 1000 FEET.
9
JUMPERS NOT NEEDED IF I/O OPTION BD IS RS485 EXPIO: 2015452-001
2017475-001/002/003 RS485 DEVICE
FCU/RTU
FCU/RTU
MODEL
MODEL
66XX
66XX
64XX
BLK
67XX
64XX
BLK
67XX WHT
68XX
68XX
WHT
CABLE BELDEN #9841
OR EQUIV
4
5
6
7
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING
NO.
REV
2015225 AM
SHEET
4
OF
LAST FCU/RTU
2 WIRE CONFIG 64XX
64XX REMOTE COMM 1 SHLD 3 2 1
6
BLK
4
WHT
REMOTE COMM 2
66XX
6400 DB PCBA
TERM BD
2015333-XXX OR
2010232-001 TB1
2100204-XXX (CB195) 2102838-XXX (XFC G4)
COMM SHLD
1
GRN
5
BRN
6
BLK
RED
7
WHT
BLU
8
W/COMM MODULE
J4
SHLD
3
13
2
J11
BLK
J4
1
12
WHT
J12
JUMPER
JUMPER ON J11 TO BE
JUMPER ON J12 TO BE
PLACED ON PINS 1 & 2
PLACED ON PINS 1 & 2
6713/6714
1212006-702
J4 OR J5 OR J6
W/ RS485 MODULE
9
2X
6490/6890 RTU W/RS485 MODULE
6490/6890 RTU W/RS485 MODULE
REMOTE COMM 1
REMOTE COMM 2 J6
BUS (-)
6
BLK
BUS (+)
4
WHT
6713/6714 W/RS485 I/O OPTION CARD
TRM (-)
4
2
BUS (-)
6
BLK
3
BUS (+)
8
WHT
TRM (+)
7
J18 (J4) J19 (J5) J20 (J6) JUMPER TO BE PLACED ON PINS 1 & 2
8A
WHT
BUS(-)
6A
BLK
J4
1
JUMPER
9
1
2
J6
BUS(+)
3
1
J7
2
BUS(+)
8B
WHT
BUS(-)
6B
BLK
3
J10
JUMPER ON J7 TO BE
JUMPER ON J10 TO BE
PLACED ON PINS 1 & 2
PLACED ON PINS 1 & 2
2X
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
5
OF
FIRST OR INTERMEDIATE 2 WIRE CONFIG 64XX
64XX
REMOTE COMM 1
2015333-XXX OR
5
6 BLK
2100204-XXX (CB195) 2102838-XXX (XFC G4)
BLK
COMM SHLD
1
BLK
BRN
6
BLK
WHT
RED
7
WHT
W/COMM MODULE
7
3
TB1
6400 DB PCBA
WHT
4 WHT
66XX FCU
REMOTE COMM 2
J4
SHLD
3
2
2
1
1
J11
J12
12
WHT
13
BLK
SHLD
JUMPER ON J11 TO BE PLACED ON PINS 2 & 3 JUMPER ON J12 TO BE PLACED ON PINS 2 & 3 6713/6714
J4 OR J5 OR J6
W/ RS485 MODULE
6490/6890 RTU
6490/6890 RTU
W/RS485 MODULE
W/RS485 MODULE
REMOTE COMM 1
REMOTE COMM 2 J6
WHT
BLK
BUS (+)
4
BUS (+)
5
BUS (-)
6
BUS (-)
7
WHT
6713/6714
BLK
J6
BUS(+)
8A
WHT
BUS(-)
6A
BLK
BUS(+)
8B
WHT
BUS(-)
6B
BLK
W/ RS485 CARD J4
1
WHT
2
BLK
1
BUS (+)
8
WHT
BUS (-)
6
BLK
2
3
1
J7
2
3
J10
3
J18 (J4) J19 (J5) J20 (J6)
JUMPER ON J7 TO BE
JUMPER ON J10 TO BE
PLACED ON PINS 2 & 3
PLACED ON PINS 2 & 3
JUMPER TO BE PLACED ON PINS 2 & 3
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
6
OF
OPTIONAL EQUIPMENT RS485 SPECIFICATIONS: 4
ALL FCU OF SAME MODEL ARE WIRED IDENTICAL EXCEPT THE LAST FCU.
5
66XX FCU's AND 64XX FCU's MAY BE MIXED TOGETHER.
6
MAX NUMBER OF LOADS THAT MAY BE CONNECTED IN SERIES IN THIS SITUATION USING RS485 COMMUNICATION IS 10.
7
TOTAL LENGTH OF RS485 CABLE IN THIS SITUATION NOT TO EXCEED 1000 FEET.
9
JUMPERS NOT NEEDED IF I/O OPTION BD IS RS485 EXPIO: 2015452-001
RS485 DEVICE
FCU/RTU
FCU/RTU
MODEL
MODEL
66XX
66XX
64XX
BRN
67XX
RED
68XX
2017475-001/002/003
4
5
6
7
64XX 67XX 68XX
BRN RED
VIO
VIO
BLK
BLK
GRA
GRA
RS485
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
7
OF
64XX
LAST FCU/RTU
REMOTE COMM 2 64XX
66XX
6400 DB PCBA
REMOTE COMM 1
TERM BD
2015333-XXX
2010232-001
OR
SHLD 6
6
BRN
2100204-XXX (CB181) 2102838-XXX (XFC G4)
1212006-702
W/COMM MODULE
3
J4
2
4
4
RED
8
8
VIO
1
1
BLK
1
16 16
J11
GRA
J4
TB1
JUMPER 2X
5
12 12
RED
BRN
6
BRN
14 14
VIO
RED
7
RED
BLK
BLU
8
VIO
11
VIO
BLK
3
BLK
2
GRA
2
1
16 16
GRA
RESISTOR ASSY 2011698-001
SHLD
JUMPER ON J11 TO BE
GRN
PLACED ON PINS 1 & 2 1.5K
JUMPER ON J12 TO BE PLACED ON PINS 1 & 2
6713/6714
WHT
W/RS485 I/O OPTION CARD J4
GND
2
BLK
BUS(+)
4
RED
BUS(+)
5
BUS(-)
6
BUS(-)
7
RRTS
8 12
OPER 1
2
3
J18 (J4) J19 (J5) J20 (J6)
JUMPER
GND
2
TRM(-)
4
OPER
12
GRA
BUS(-)
6
BRN
TRM(+)
7
VIO
BUS(+)
8
GRA
AO(-)
9
BRN
4
6713/6714
J4 OR J5 OR J6
W/ RS485 MODULE
CABLE, RS485, SPECIAL 2011648-001
BRN
1
1
1
13 13
3
J12
COMM SHLD
JUMPER
9
9
BLK
6490/6890 RTU W/ RS485 MODULE
6490/6890 RTU W/ RS485 MODULE
REMOTE COMM 1
RRTS
10
AO(+)
11
REMOTE COMM 2 J6
RED
J6
BUS(+)
8A
RED
BUS(-)
6A
BRN
RRTS
BUS(+)
8B
RED
BUS(-)
6B
BRN
5A
VIO
RRTS
5B
VIO
GND
2A
BLK
GND
2B
BLK
OPER
4A
GRA
OPER
4B
GRA
VIO 1
2
3
1
J7
2
3
J10
JUMPER ON J7 TO BE
JUMPER ON J10 TO BE
PLACED ON PINS 1 & 2
PLACED ON PINS 1 & 2
JUMPER TO BE PLACED ON PINS 1 & 2 SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
8
OF
FIRST OR INTERMEDIATE FCU/RTU
64XX 64XX
REMOTE COMM 1
REMOTE COMM 2
SHLD J4 BRN
RED
6
6
7
7
4
4
5
5
TB1
2015333-XXX
W/COMM MODULE J4
RED
VIO
8
8
VIO
BLK
1
1
BLK
GRA
66XXY FCU
6400 DB PCBA
BRN
3
GRA
16 16 3
5
12 12
RED
BRN
BRN
6
BRN
VIO
RED
RED
7
RED
1
BLU
8
VIO
VIO
11
VIO
BLK
BLK
3
BLK
2
GRA
BLK
16 16
J12
GRN
GRA
SHLD
2
GRA
1
1.5K
JUMPER ON J12 TO BE
J11
CABLE, RS485, SPECIAL 2011648-001
BRN
1
1
1
13 13
14 14
2
COMM SHLD
PLACED ON PINS 2 & 3
4
WHT
JUMPER ON J11 TO BE PLACED ON PINS 2 & 3
RESISTOR ASSY 2011698-001
6713/6714 W/ RS485 MODULE
6713/6714 W/RS485 I/O OPTION CARD
J4 OR J5 OR J6
J4 GND
2
BLK
BUS(+)
4
RED
BUS(+)
5
BLK
RED
BUS(-)
6
BRN
BUS(-)
7
VIO
RRTS
8
VIO
12
GRA
OPER
GRA 1
2
3
J18 (J4) J19 (J5) J20 (J6)
BRN
GND
2
TRM(-)
4
GRA
OPER
12
GRA
BRN
BUS(-)
6
TRM(+)
7
BUS(+)
8
AO(-)
9
BLK
RED
VIO
RRTS
10
AO(+)
11
BLK
6490/6890 RTU W/ RS485 MODULE
6490/6890 RTU W/ RS485 MODULE
REMOTE COMM 1
REMOTE COMM 2 J6
J6
BUS(+)
8A
RED
BRN
BUS(-)
6A
BRN
RRTS
5A
RED
GND OPER
VIO
1
2
3
BUS(+)
8B
RED
BUS(-)
6B
BRN
VIO
RRTS
5B
VIO
2A
BLK
GND
2B
BLK
4A
GRA
OPER
4B
GRA
1
J7
2
3
J10
JUMPER ON J7 TO BE
JUMPER ON J10 TO BE
PLACED ON PINS 2 & 3
PLACED ON PINS 2 & 3
JUMPER TO BE PLACED ON PINS 2 & 3
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
2015225 AM
SHEET
9
OF
8
GLOSSARY OF TERMS DEFINITION
TITLE
PART NUMBER
LAST FCU
LAST FLOW COMPUTER ON THE RS-485 COMMUNICATIONS BUS
6410 FCU
FLOW COMPUTER UNIT WITH 6400 DIGITAL BOARD (P/N 2015189-005/006 OR 2015333-002/003), GAS ORIFICE
6411 FCU
FLOW COMPUTER UNIT WITH 6400 DIGITAL BOARD (P/N 2015189-005/006 OR 2015333-002/003), PULSE INPUT
6413 FCU
6414 FCU
6713 FCU
6714 FCU
FLOW COMPUTER UNIT WITH 6400 DIGITAL BOARD (P/N 2015189-005/006 OR 2015333-002/003), GAS ORIFICE WITH COMMUNICATIONS OPTION
FLOW COMPUTER UNIT WITH 6400 DIGITAL BOARD (P/N 2015189-005/006 OR 2015333-002/003), PULSE INPUT WITH COMMUNICATIONS OPTION
FLOW COMPUTER UNIT WITH CB181 ELECTRONIC BOARD (P/N 2015382-001/002), GAS ORIFICE, WITH COMMUNICATIONS AND VALVE CONTROL OPTION
FLOW COMPUTER UNIT WITH CB181 ELECTRONIC BOARD (P/N 2015382-001/002), PULSE INPUT, WITH COMMUNICATIONS AND VALVE CONTROL OPTION
6610 FCU
GAS ORIFICE FLOW COMPUTER UNIT IN CAST ALUMINUM CASE
6611 FCU
PULSE INPUT FLOW COMPUTER UNIT IN CAST ALUMINUM CASE
6612 FCU
LIQUID ORIFICE FLOW COMPUTER UNIT IN CAST ALUMINUM CASE
6613 FCU
GAS ORIFICE FLOW COMPUTER UNIT IN CAST ALUMINUM CASE WITH REMOTE COMMUNICATIONS OPTION
6614 FCU
PULSE INPUT FLOW COMPUTER UNIT IN CAST ALUMINUM CASE WITH REMOTE COMMUNICATIONS OPTION
6615 FCU
LIQUID ORIFICE FLOW COMPUTER UNIT IN CAST ALUMINUM CASE WITH REMOTE COMMUNICATIONS OPTION
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS) MODEM 1000
1181027-CS
MDS 1000 W/O MODEM
1181028-CS
JOHNSON RADIO W/O MODEM
TOTALFLOW PART NUMBER FOR JOHNSON TRANSCEIVER WITHOUT INTERNAL MODEM
1181037-CS
REPCO RADIO W/O MODEM
TOTALFLOW PART NUMBER FOR REPCO TRANSCEIVER WITHOUT INTERNAL MODEM
1181043-CS
RNET RADIO W/O MODEM
TOTALFLOW PART NUMBER FOR MOTOROLA RNET TRANSCEIVER WITHOUT INTERNAL MODEM
1193950-001
RS232/RS485 PATTON CONVERTER
MODEL 285 PATTON RS-232 TO RS-485 OR 422 CONVERTER (OBSOLETE, REPLACED BY 1193950-002)
1193950-002
RS232/RS485 PATTON CONVERTER
MODEL 2085 PATTON RS-232 TO RS-485 OR 422 CONVERTER
TRANSCEIVER WITH INTERNAL MODEM
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING
NO.
REV
SHEET
2015225 AM 10
OF
8
GLOSSARY OF TERMS (CONT) DEFINITION
TITLE
PART NUMBER
1467000-001
SAMPLER, Y-Z
THIRD PARTY PROPORTIONAL SAMPLER SUPPLIED BY Y-Z INDUSTRIES
1468001-001
ACTUATOR, E TO P
THIRD PARTY ELECTRICAL-TO-PNEUMATIC CONVERTER PROVIDING 3 TO 15 PSI OUTPUT FOR PNEUMATIC VALVE
1468001-002
ACTUATOR, E TO P
THIRD PARTY ELECTRICAL-TO-PNEUMATIC CONVERTER PROVIDING 6 TO 30 PSI OUTPUT FOR PNEUMATIC VALVE
2000003-001
COMM INTERFACE PCBA
RS-232 INTERFACE BOARD (COMPATIBLE WITH 6600 AND 6700 FLOW COMPUTER UNITS SUPPORTING 50 PIN INTERFACE CONNECTOR) REPLACED BY 2012878-001
2010124-001
XDCR TEMP SENSOR
TRANSDUCER TEMPERATURE SENSOR
2010210-002/003
RS485 COMM PCBA
RS-485 INTERFACE BOARD (COMPATIBLE WITH 6600 AND 6700 FLOW COMPUTER UNITS SUPPORTING 50 PIN INTERFACE CONNECTOR)
2010210-004
RS485 COMM PCBA W/DIODE
RS-485 INTERFACE BOARD WITH REQUEST-TO SEND (RTS) ISOLATION DIODE INCLUDED ON BOARD (COMPATIBLE WITH 6600 AND 6700 FLOW COMPUTER UNITS SUPPORTING 50 PIN INTERFACE CONNECTOR)
2010232-001
TERMINATION BOARD ASSY
STANDARD TERMINATION BOARD FOR 66XX FLOW COMPUTER
2010282-001
ELECTRONIC BOARD ASSY
ELECTRONIC BOARD (282 BOARD) FOR 66XX FLOW COMPUTER
2010283-003/004
VCI PCBA
2011613-001
RADIO MODEM ASSY
RS-485 TO MODTONE CONVERTER (SUPPORTS FSK MODULATION AT 1200 BAUD)
2011690-001
EXPIO PCBA, RS485
PLUG-IN RTU BOARD RS-485 VERSION (OBSOLETE, REPLACED BY 2012901-001 AND 2015452-001)
2011690-002
EXPIO PCBA, RS232
PLUG-IN RTU BOARD RS-232 VERSION (OBSOLETE, REPLACED BY 2012901-002 AND 2015452-002)
2011720-003
AC PWR SPLY
110 VOLT AC TO 12 VOLT DC CHARGER POWER SUPPLY (160 MA OUTPUT CURRENT MAX.)
2011720-004
AC PWR SPLY, 110V/10W
110 VOLT AC TO 12 VOLT DC CHARGER POWER SUPPLY (500 MA OUTPUT CURRENT MAX.)
2011720-005
AC PWR SPLY, 240V/10W
240 VOLT AC TO 12 VOLT DC CHARGER POWER SUPPLY (500 MA OUTPUT CURRENT MAX.)
2011722-001 THRU -006
PCBA ASSY, DACU
W/D, REPLACED BY 2012692-XXX
2011772-001
ELECTRONIC BOARD ASSY
ELECTRONIC BOARD (772 BOARD) FOR 66XX FCU, ALSO USED IN PULSE METER
2011855-001
PULSER, 50 REV, IMAC
2011855-002
PULSER, 100 REV, IMAC
VERSATILE COMMUNICATIONS INTERFACE (VCI) BOARD. PRIMARY FUNCTION IS DIGITAL VALVE CONTROL. INTERFACE BOARD HAS 4 DIGITAL INPUTS AND OUTPUTS.
CAN BE ADDED TO 66XX OR 6713 FLOW COMPUTER TO PROVIDE VALVE CONTROL FUNCTION.
THIRD PARTY IMAC MECHANICAL TO ELECTRICAL PULSER FOR PULSE INPUT FLOW COMPUTER UNITS.
(50 PULSES PER REVOLUTION) THIRD PARTY IMAC MECHANICAL TO ELECTRICAL PULSER FOR PULSE INPUT FLOW COMPUTER UNITS.
(100 PULSES PER REVOLUTION)
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
SHEET
2015225 AM 11
OF
8
GLOSSARY OF TERMS (CONT) DEFINITION
TITLE
PART NUMBER
2011903-001/002
RS485/SINGLE AO PCBA
OBSOLETE, REPLACED BY 2011903-003
2011903-003
RS485/SINGLE AO PCBA W/DIODE
RS-485 INTERFACE BOARD WITH SINGLE ANALOG OUTPUT
2011905-XXX
RTD PROBE
TEMPERATURE PROBE FOR THE FLOW COMPUTER UNIT (100 OHM PLATINUM)
2011982-XXX
RS485/RS232 CONV
RS-485/RS-232 BARRIER CONVERTER (DIV 1 BARRIER)
2012511-001
EXP TERM BOARD
PLUG-IN RTU REMOTE TERMINATION BOARD (REPLACED BY 2017220-001/002)
2012630-003
UCI, RADIO DIV 2
UNIVERSAL COMMUNICATIONS INTERFACE (UCI). USED TO INTERFACE RADIO EQUIPMENT WITH TOTALFLOW HARDWARE. (CAN CONVERT RS-232 TO RS-485, RS-485 TO MODTONES OR RS-232 TO MODTONE SIGNALS) MODEM SUPPORTS FSK MODULATION AT 1200 BAUD ONLY.
2012692-XXX
DACU PCBA
REPLACED BY 2015080-XXX
2012803-004
COMPUTER BOARD 180 PCBA
ELECTRONIC BOARD (CB-180 BOARD) FOR 66XX FCU
2012824-001
SURGE SUPPRESSOR MODULE
RS-485 SURGE SUPPRESSOR MODULE
2012826-001
VCI TERM BOARD
VALVE CONTROL INTERFACE BOARD FOR 6600 FLOW COMPUTER (OBSOLETE, REPLACED BY 2012826-002) W/FDA200
2012826-002
VCI TERM BOARD
VALVE CONTROL INTERFACE BOARD FOR 6600 FLOW COMPUTER
2012878-001
COMM INTERFACE PCBA
RS-232 INTERFACE BOARD (COMPATIBLE WITH 6600 OR 6700 FLOW COMPUTER UNITS SUPPORTING 50 PIN INTERFACE CONNECTOR)
2012881-001
CONVERTER, M/P
2012901-001
EXPIO PCBA, RS485
PLUG-IN RTU BOARD RS-485 VERSION (OBSOLETE, REPLACED BY 2015452-001)
2012901-002
EXPIO PCBA, RS232
PLUG-IN RTU BOARD RS-232 VERSION (OBSOLETE, REPLACED BY 2015452-002)
2012903-001
RS485 COMM W/SINGLE AO
SINGLE ANALOG OUTPUT INTERFACE BOARD (OPTION ON 6600 AND 6700 FLOW COMPUTER)
2012911-001
COMM INTERFACE W/AO PCBA
QUAD ANALOG OUTPUT INTERFACE BOARD (OPTION ON 6600 AND 6700 FLOW COMPUTER)
2012925-001
SWITCH ASSY VALVE DISABLE
SPECIAL ON/OFF SWITCH USED TO DISABLE VALVE CONTROL
2012948-001
TERM BD-CIAO
TERMINATION BOARD FOR QUAD ANALOG OUTPUT INTERFACE FIELD WIRING
2015051-
CHGR/REG ASSY
THIRD PARTY SOLAR CHARGER REGULATOR ASSEMBLY (8 AMP CHARGING CAPABILITY)
2015080-XXX
RTU PCBA
REPLACED BY 2017245-XXX
THIRD PARTY FAIRCHILD ELECTRICAL-TO-PNEUMATIC CONVERTER PROVIDING 3 TO 15 OR 6 TO 30 PSI OUTPUT FOR PNEUMATIC VALVE.
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
SHEET
2015225 AM 12
OF
8
GLOSSARY OF TERMS (CONT) DEFINITION
TITLE
PART NUMBER
2015133-001
RS232 COMM INTERFACE
RS-232 INTERFACE BOARD FOR THE 6400 FLOW COMPUTER (WITHOUT REQUEST-TO-SEND ISOLATION FUSE)
2015189-XXX
6400 DIGITAL PCBA
MODEL 6400 ELECTRONIC BOARD (REPLACED BY 2015333-XXX)
2015192-001
RS232 COMM MODULE
RS-232 COMMUNICATIONS MODULE FOR 6400 OR 6700 FLOW COMPUTER UNIT
2015193-001
RS485 COMM MODULE
2015193-002
RS485 COMM MODULE
2015247-001
RELAY ASSY, TQ2E-12
SPECIAL FORM "C" RELAY PROVIDING UP TO 1 AMP AT 12 VDC CURRENT CARRYING CAPABILITY
2015333-XXX
6400 DIGITAL PCBA II
MODEL 6400 ELECTRONIC BOARD
2015382-XXX
CB181 PCBA
MODEL 6700 ELECTRONIC BOARD
2015440-001
PWR SPLY ASSY, 120V
120 VOLT AC TO 12 VOLT DC CHARGER FOR BTU TRANSMITTER
2015440-003
PWR SPLY ASSY, 230V
230 VOLT AC TO 12 VOLT DC CHARGER FOR BTU TRANSMITTER
2015440-005
PWR SPLY ASSY, 120V/12VDC
120 VOLT AC TO 12 VOLT DC CHARGER FOR BTU TRANSMITTER
2015440-006
PWR SPLY ASSY, 230V/12VDC
230 VOLT AC TO 12 VOLT DC CHARGER FOR BTU TRANSMITTER
2015440-007
PWR SPLY ASSY, DC/DC
24 VOLT DC TO 12 VOLT DC CHARGER POWER SUPPLY FOR BTU TRANSMITTER
2015445-002
RS232/RS485 PATTON CONVERTER
2015445-003
RS232/RS485 PATTON CONVERTER
2015452-001
EXPIO PCBA, RS485
PLUG-IN RTU BOARD RS-485 (REPLACES 2011690-001 AND 2012901-001)
2015452-002
EXPIO PCBA, RS232
PLUG-IN RTU BOARD RS-232 (REPLACES 2011690-002 AND 2012901-002)
2017220-001
EXP TERM BOARD
PLUG-IN RTU REMOTE TERMINATION BOARD
2017220-002
EXP TERM BOARD
PLUG-IN RTU REMOTE TERMINATION BOARD WITH PLUGGABLE PHOENIX TYPE CONNECTORS
2017240-001
PREAMP ASSY
2017245-XXX
RTU PCBA
RS-485 COMMUNICATIONS MODULE FOR 6400 OR 6700 FLOW COMPUTER UNIT
(REPLACED BY 2015193-002) RS-485 COMMUNICATIONS MODULE FOR 6400 OR 6700 FLOW COMPUTER UNIT
WITH REQUEST-TO-SEND (RTS) ISOLATION DIODE ON BOARD
MODEL 285 PATTON RS-232 TO RS-485 OR 422 CONVERTER MOUNTED
ON BRACKET WITH CABLE ASSY (OBSOLETE, REPLACED BY 2015445-003) TOTALFLOW ASSY, MODEL 285 PATTON RS-232 TO RS-485 OR 422 CONVERTER MOUNTED ON BRACKET WITH CABLE ASSY
AMPLIFIER ASSEMBLY FOR CONVERTING LOW LEVEL SIGNALS FROM LINEAR PRIMARY FOR PULSE INPUT FLOW COMPUTER UNITS. RTU ELECTRONIC BOARD
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
SHEET
2015225 AM 13
OF
8
GLOSSARY OF TERMS (CONT) DEFINITION
TITLE
PART NUMBER
2017226-001/002
MODEM D/C, 2400 BAUD OR 9600 BAUD
MODEM DATEL WITH CERMETEK MODEM CHIP
2012630-005
UCI, DESKTOP
UNIVERSAL COMMUNICATIONS INTERFACE (UCI). USED TO INTERFACE DESKTOP PC TO TOTALFLOW HARDWARE. (CAN CONVERT RS-232 TO RS-485, RS-485 TO MODTONES OR RS-232 TO MODTONE SIGNALS) MODEM SUPPORTS FSK MODULATION AT 1200 BAUD ONLY.
2012630-006
UCI, MODEM
UNIVERSAL COMMUNICATIONS INTERFACE (UCI). USED TO INTERFACE A DIAL-UP MODEM TO TOTALFLOW EQUIPMENT. (RS-232/RS-485)
2017273-001
RS485 MODEM INTERFACE
RS-232 TO RS-485 CONVERTER USED WITH THE DATEL MODEM
DGH BOX
THIRD PARTY RS-232/RS-485 CONVERTER FOR OFFICE
TRANSPONDER
OBSOLETE
SOLAR PANEL 12V, 5W
NO DESCRIPTION REQUIRED
SOLAR PANEL 12V, 10W
NO DESCRIPTION REQUIRED
SOLAR PANEL 12V, 20W
NO DESCRIPTION REQUIRED
SOLAR PANEL 12V, 30W
NO DESCRIPTION REQUIRED
PWR SPLY, 24VIN/12VOUT
24 VOLT DC TO 12 VOLT DC CHARGER POWER SUPPLY
MODEL 8000 BTU-XMTR
GP - DIV2 NRTL/C - DIV 1 NRTL/C
MODEL 8100 BTU-XMTR
CENELEC-GOST
2012546-003
ANALYZER INTERFACE UNIT, INTERFACES BETWEEN BTU TRANSMITTER AND
6680 AIU
FLOW COMPUTER UNITS SUPPLYING GAS COMPOSITION INFORMATION FOR VOLUME CALCULATIONS.
6690 RTU
STAND-ALONE REMOTE TERMINAL UNIT IN CAST ALUMINUM CASE
6670 OPTL EQUIP ENCL
REMOTE COMMUNICATIONS ENCLOSURE SUPPORTING DC POWER SYSTEM
6671 OPTL EQUIP ENCL
LARGE REMOTE COMMUNICATIONS ENCLOSURE SUPPORTING DC POWER SYSTEM
6790 RTU
STAND-ALONE REMOTE TERMINAL UNIT IN LIGHT WEIGHT ALUMINUM CASE
6890 RTU
STAND-ALONE REMOTE UNIT, CAPABLE OF HOLDING TWO 70AH BTRY'S.
MODEM, UDS212A.LP
THIRD PARTY AUTOANSWER MODEM (OBSOLETE)
CCU
CENTRAL COLLECTION UNIT (CCU) SOFTWARE. OFFICE BASED SOFTWARE PACKAGE USED TO COLLECT, ARCHIVE, EDIT AND REPORT ON FLOW COMPUTER DATA
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING
NO.
REV
SHEET
2015225 AM 14
OF
8
DEFINITION
TITLE
PART NUMBER
MDS 1000 W/MODEM MDS 1000U W/MODEM MDS 2310 W/O MODEM MDS 2310 W/MODEM RNET RADIO W/MODEM MDS 9310 W/MODEM METRICOM RADIO W/MODEM
2015404-001
GLOSSARY OF TERMS (CONT)
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS) MODEM 1000 TRANSCEIVER WITH INTERNAL MODEM
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS) MODEM 1000 SYNTHESIZED TRANSCEIVER WITH INTERNAL MODEM
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS) MODEM 2310 TRANSCEIVER WITHOUT INTERNAL MODEM
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS) MODEM 2310 TRANSCEIVER WITH INTERNAL MODEM
TOTALFLOW PART NUMBER FOR MOTOROLA RNET TRANSCEIVER WITH INTERNAL MODEM
TOTALFLOW PART NUMBER FOR MICROWAVE DATA SYSTEMS (MDS)
SPREAD SPECTRUM TRANSCEIVER WITH INTERNAL 4800 BAUD MODEM TOTALFLOW PART NUMBER FOR METRICOM'S SPREAD SPECTRUM TRANSCEIVER WITH INTERNAL 9600 BAUD MODEM
AAI EMS 12A
GAS CHROMATOGRAPH
DANIELS DANALYZER
DANIEL'S GAS CHROMATOGRAPH
SAMPLER, Y-Z
THIRD PARTY PROPORTIONAL SAMPLER SUPPLIED BY Y-Z INDUSTRIES (DANAPAK 2000 SERIES)
JAMESBURY VALVE
THIRD PARTY VALVE AND DC ACTUATOR
LEDEEN VALVE
THIRD PARTY VALVE AND DC ACTUATOR WITH TORQUE SWITCH
VALCON ACTUATOR
THIRD PARTY VALVE AND DC ACTUATOR
WORCHESTER ACTUATOR
THIRD PARTY VALVE AND DC ACTUATOR
CELLULAR TELEPHONE
MICROCOM CDL-100 (OBSOLETE)
AUX PORT ADAPTER
SECOND RS-232 OR RS-485 COMMUNICATIONS PORT FOR 2012803-004 (CB-180) ELECTRONICS BOARD
TERM BD ASSY AUX PORT
TERMINATION BOARD FOR SECOND COMMUNICATIONS PORT BOARD RS-485 INTERFACE BOARDS WHICH PLUG INTO THE 50 PIN EXPANSION CONNECTOR ON
RS485 I/O OPTION CARD
6600 OR 6700 FLOW COMPUTER UNITS. ALTERNATE METHOD OF DUTY CYCLING COMMUNICATIONS DEVICE POWER TO CONSERVE SYSTEM
COMM SCHEDULER FEATURE
BATTERY POWER. THIS METHOD WILL ALLOW THE USER TO SPECIFY SPECIFIC TIMES DURING THE DAY TO ENERGIZE THE COMMUNICATIONS DEVICE FOR A SPECIFIED PERIOD OF TIME.
REFER TO TECHNICAL BULLETIN #44 FOR SETUP DETAILS.
SCALE
NONE
SIZE
DOC TYPE
B
WI
DRAWING NO.
REV
SHEET
2015225 AM 15
OF