Preview only show first 10 pages with watermark. For full document please download

Atersa Driver Item No.: 421.055 Description Of Functions

   EMBED


Share

Transcript

ATERSA DRIVER Item No.: 421.055 DESCRIPTION OF FUNCTIONS WEB’log driver for supporting Atersa inverters. TECHNICAL DATA Max. number of inverters: Active power control via WEB´log Pro: Active power control via PCU: Reactive power control via PCU: Communication interface: Bus speed: Protocol (transmission): Current sensor compatibility: i’checker: i’catcher: INV manufacturer: Modbus periphery (sensor systems, meters…): Modbus: Periphery interface: 31 None None None RS485 38400 bps 8N1 Max. 100 i’checkers Max. 64 Geräte None max. 64 devices Ethernet (TCP) RS422 (RTU) – The interface is used as an RS485 interface by connecting pin 2 to pin 3 and pin 4 to pin 5. The Universal RS Cable (Item No. 422.537) can also be used for this purpose. RESTRICTIONS Maximum number of Modbus devices A maximum of 64 devices can be queried, the type or communication interface is irrelevant. Modbus sensor compatibility For details of what devices are already supported, please see the sensor datasheets. Modbus RTU Various Modbus devices can only be queried together if the serial communication parameters are identical (baud rate, number of data bits, parity, stop bits). Measurement values recorded The measurement values actually recorded may vary depending on the inverter model or the inverter firmware. Information subject to change, errors and omissions excepted / As at 07-2014 1/2 MEASUREMENT VALUES RECORDED P_AC U_ACMAX I_ACMAX U_ACMIN I_ACMIN U_AC U_DCMAX U_DC I_DC E_INT I_LEAK E_TOTAL R_ISO E_MAX I_LEAKMAX t_MIN F_AC Z_AC U_VCCMAX D_DIS T_WR AC power AC maximum voltage AC maximum current AC minimum voltage AC minimum current AC voltage DC maximum voltage DC voltage DC current Energy interval Leakage current Total energy Insulation resistance Maximum energy Maximum leakage current Minimum time for alarm Grid frequency Grid impedance Vcc maximum Distortion reactive power Inverter temperature SUPPORTED INVERTERS Grid-coupled systems CICLO 3000 CICLO 6000 Please contact Sales for details of compatibility with inverters not listed. Telephone +49 (0)821 34666 - 80 E-mail [email protected] meteocontrol GmbH | Spicherer Straße 48 | 86157 Augsburg | Telephone +49 (0)821 34666 - 0 | Fax +49 (0)821 34666 - 11 E-Mail [email protected] | Web www.meteocontrol.com Information subject to change, errors and omissions excepted / As at 07-2014 2/2