Transcript
ATEX Compliant Solid-state Switch / Direct Mounting
D-M9N(V)-588•D-M9P(V)-588•D-M9B(V)-588 Auto Switch Specifications PLC: Programmable Logic Controller
D-M9쏔/D-M9쏔V (With indicator light) Auto switch part no.
D-M9N
D-M9NV
D-M9P
D-M9PV
D-M9B
D-M9BV
Electrical entry direction
In-line
Perpendicular
In-line
Perpendicular
In-line
Perpendicular
ATEX Category
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Wiring type NPN
Applicable load
PNP
—
IC circuit, Relay, PLC
24 VDC relay, PLC
Power supply voltage
5, 12, 24 VDC (4.5 to 28 VDC)
—
Current consumption
10 mA or less
Load voltage
—
28 VDC or less 40 mA or less
Load current Internal voltage drop Leakage current
24 VDC (10 to 28 VDC)
—
2.5 to 40 mA
0.8 V or less
4 V or less
100 µA or less at 24 VDC
0.8 mA or less
Indicator light
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
2-wire
3-wire
Output type
Red LED illuminates up.
• Lead wire: oil-proof heavy-duty vinyl cord 2.7 x 3.2 elipse, 0.15 mm2, 2 cores (D-M9B), or 3 cores (D-M9N and D-M9P) • This category 3 type autoswitch can only be used in zones 2 and 22.
How to Order Internal circuits
Standard Model Number
D-M9N, D-M9NV
D-M9 N V L -588
Switch main circuit
DC (+) Brown
OUT Black
Suffix for ATEX certified CAT.3
Series Model Number
Lead wire length
Wiring and output DC (–) Blue
D-M9P, D-M9PV Switch main circuit
DC (+) Brown
OUT Black DC (–) Blue
D-M9B, D-M9BV Switch main circuit
OUT (+) Brown
OUT (–) Blue
38
N P B
Nil L Z
3-wire NPN 3-wire PNP 2-wire
0.5m 3m 5m
Electrical entry Nil V
In-line Perpendicular
ATEX Compliant Solid State Switch/Band Mounting
D-H7A2-588 Specifications D-H7 (With indicator light)
Grommet
Auto switch model number ATEX Category
PLC: Programmable Logic Controller
D-H7A2 II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67 3 wire
Wiring Output
PNP IC circuit/Relay/PLC
Application
5/12/24V DC (4.5 to 28 VDC)
Power voltage
10mA or less
Current consumption Load voltage
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Load current
80mA or less
Internal voltage drop
0.8V or less
Current leakage
100µA or less at 24 VDC
Indicator light Lead wire
Red LED lights up
Oilproof heavy-duty vinyl cord, ø3.4, 0.2mm2, 3 cores (Brown, Black, Blue)
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
D-H7A2
-588 Suffix for ATEX certified CAT.3
Internal Circuit
Switch No.
D-H7A2
Main Circuit of switch
DC(+) Brown
Lead wire length No number L Z
0.5m 3m 5m
OUT Black
DC(–) Blue
39
ATEX Compliant Solid State Switch/Rail Mounting
D-F7P(V)-588 Specifications D-F7P, D-F7PV (With indicator light)
Grommet
Auto switch model number ATEX Category
PLC: Programmable Logic Controller
D-F7PV D-F7P II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Electrical entry 3 wire
Wiring Output
PNP IC circuit/Relay/PLC
Application
5/12/24V DC (4.5 to 28VDC)
Power voltage
10mA or less
Current consumption Load voltage Load current
80mA or less
Internal voltage drop
0.8V or less 100µA or less at 24VDC
Current leakage Indicator light Lead wire
Red LED lights up
Oilproof heavy-duty vinily cord, ø3.4, 0.2mm2, 3 cores (Brown, Black, Blue)
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
D-F7P
-588 Suffix for ATEX certified CAT.3
Switch No.
Internal Circuit Electrical entry
D-F7P, D-F7PV
Switch main circuit
DC(+) Brown
OUT Black DC(–) Blue
40
No number V
Right arm Perpendicular
Lead wire length No number L Z
0.5m 3m 5m
ATEX Compliant Solid State Switch/Tie-rod Mounting
D-F5P-588 Specifications D-F5P (With indicator light)
Grommet
PLC: Programmable Logic Controller
D-F5P
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category
3 wire
Wiring Output
PNP IC circuit/Relay/PLC
Application
5/12/24V DC (4.5 to 28VDC)
Power voltage
10mA or less
Current consumption Load voltage
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Load current
80mA or less
Internal voltage drop
0.8V or less ≤ 100µA at 24VDC
Current leakage
Red LED lights up
Indicator light Lead wire
Oilproof heavy-duty vinyl cord, ø4, 0.3mm2, 3 cores (Brown, Black, Blue)
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
Internal Circuit D-F5P
Main circuit of switch
DC(+) Brown
D-F5P
-588 Suffix for ATEX certified CAT.3
OUT Black DC(–) Blue
Switch No.
Lead wire length No number L Z
0.5m 3m 5m
41
ATEX Compliant Solid State Switch/Direct Mounting
D-Y7P(V)-588 Specifications
Grommet
PLC: Programmable Logic Controller
D-Y7P/D-Y7PV (With indicator light) ATEX Category
D-Y7P D-Y7PV II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Electrical entry
In-line
Auto switch model number
Perpendicular
Wiring
3 wire PNP
Output Application
IC circuit/Relay/PLC
Power voltage
5/12/24V DC (4.5 to 28VDC)
Current consumption
10mA or less
Load voltage Load current
80mA or less
Internal voltage drop
0.8V or less
Current leakage
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
100µA or less at 24VDC
Indicator light Lead wire
Red LED lights up
Oilproof heavy-duty vinyl cord, ø3.4, 0.15mm2, 3 cores (Brown, Black, Blue)
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
D-Y7P
-588
Internal Circuit D-Y7P, D-Y7PV
Main circuit of switch
DC(+) Brown
Electrical entry OUT Black DC(–) Blue
42
Suffix for ATEX certified CAT.3
Switch No.
No number V
Right arm Perpendicular
Lead wire length No number L Z
0.5m 3m 5m
ATEX Compliant Reed Switch/Band Mounting
D-C73/D-C80-588 Specifications
Grommet
PLC: Programmable Logic Controller
D-C7 (With indicator light) D-C73
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category Application
Relay/PLC 24V DC
Load voltage
5 to 40mA
Max. load current and range Contact protection circuit
None
Internal voltage drop
≤ 2.4V ON: When red light emitting diode
Indicator light
D-C8 (Without indicator light) D-C80
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Relay/PLC/IC circuit
Application 24V
Load voltage
AC DC
50mA
Max. load current
40mA None
Contact protection circuit
Internal Circuit ( ): If not applicable for IEC Standard
AC 48V DC
or less
1Ω or less (Including 3m lead wire) Internal resistance • This category 3 type autoswitch can only be used in zones 2 and 22.
D-C73 Reed switch
LED Brown(Red) Resistance
Contact protective box
OUT(+) Brown(Red)
How to order
CD-P11 Zener diode
CD-P12
OUT(–) Blue(Black)
Blue(Black)
D-C Contact protective box
-588
OUT(±) Brown(Red)
Suffix for ATEX certified CAT.3
CD-P11 CD-P12
±
Reed switch
D-C80
OUT( ) Blue(Black)
Note) q In the case operation load is an inductive load. w In the case the wiring length to load is more than 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
Switch No. 73 80
With indicator lamp Without indicator lamp
Lead wire length No number L Z
0.5m 3m 5m (Except D-C80)
43
ATEX Compliant Reed Switch/Rail Mounting
D-A73(H)/D-A80(H)-588 Specifications D-A73, D-A73H (With indicator light)
Grommet
PLC: Programmable Logic Controller
D-A73, D-A73H
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category Application
Relay/PLC 24V DC
Load voltage
5 to 40mA
Load current range
None
Contact protection circuit
≤ 2.4V
Internal voltage drop
ON: When red light emitting diode
Indicator light
D-A80, D-A80H (Without indicator light) D-A80, D-A80H
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category
Relay/IC circuit/PLC
Application 50mA
Max. load current
40mA None
Contact protection circuit
1Ω or less (Including 3m lead wire)
Internal resistance Lead wire
48V AC DC
AC 24V DC or less
Load voltage
Oilproof vinyl heavy insulation cable, ø3.4, 0.2mm2, 2 cores (Brown, Blue), 0.5m
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
-588
D-A
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Suffix for ATEX certified CAT.3 Switch No.
Internal Circuit ( ): If not applicable for IEC Standard
73 80
With indicator lamp Without indicator lamp
D-A73, D-A73H Reed switch
LED Brown(Red) Resistance
Electrical Entry OUT(+) Brown(Red)
Contact protection box
Zener diode
to
CD-P11
OUT(–) Blue(Black)
CD-P12 Blue(Black)
Contact protection box CD-P11 CD-P12
OUT(±) Brown(Red) to ±
Reed switch
D-A80, D-A80H
OUT( ) Blue(Black)
Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is “>” 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
44
H
Perpendicular In-line
Lead wire length No number L Z
0.5m 3m 5m (Except A80쐽)
ATEX Compliant Reed Switch/Tie-rod Mounting
D-A54/D-A67-588 Specifications D-A5 (With indicator light)
Grommet
PLC: Programmable Logic Controllar
D-A54
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category Application
Relay/PLC
Load voltage
24V DC
Max. load current 5 to 50mA
and range Contact protection circuit
Built-in 2.4V
Internal voltage drop
ON: When red light emitting diode
Indicator light
D-A6 (Without indicator light) D-A67
Auto switch model number ATEX Category
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Application
PLC/IC circuit
Load voltage
MAX. 24V DC
Max. load current
30mA
Contact protection circuit
None ≤ 1Ω (Including 3m lead wire)
Internal resistance Lead wire
Oilproof vinyl heavy insulation cable, ø4, 0.3mm2, 2 cores (Brown, Blue), 0.5m or ø4, 0.2mm2, 3 cores (Brown, Black, Blue), 0.5m
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
D-A
-588
Internal Circuit ( ): If not applicable for IEC Standard D-A54
Suffix for ATEX certified CAT.3
Zener diode
Switch No.
Choke coil OUT(–) to Blue(Black)
LED Reed switch Resistance
OUT(+) to Brown(Red)
54 67
With indicator lamp Without indicator lamp
Lead wire length No number L Z
0.5m 3m 5m
Surge absorber
45
ATEX Compliant Reed Switch/Direct Mounting
D-A90(V)/D-A93(V)-588 Specifications PLC: Programmable Logic Controller D-A90, D-A90V (Without indicator light)
Grommet
D-A90, D-A90V
Auto swich modle number ATEX Category
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Application
IC circuit/Relay/PLC 24V
Load voltage
AC DC
or less
50mA
Max. load current
AC DC
48V
or less
40mA
Contact protection circuit
None
Internal resistance
1Ω or less (Including 3m lead wire)
D-A93, D-A93V (With indicator light) D-A93, D-A93V
Auto switch model number ATEX Category
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Application
Relay/PLC
Load voltage
24V DC
Max. load current and load current range
5 to 40mA
Contact protection circuit
None ≤ 2.4V (up to 20mA)/≤ 3V (up to 40mA)
Internal voltage drop Indicator light
ON: When red light emitting diode
Lead wire D-A90(V)/D-A93(V)
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
Oilproof vinyl heavy insulation cable, ø2.7, 0.18mm2 X 2cores (Brown, Blue)
This category 3 type autoswitch can only be used in zones 2 and 22.
Dimensions
D-A
-588
Internal Circuit ( ): If not applicable for IEC Standard Reed switch
Contact protective box CD-P11 CD-P12
OUT(±) Brown(Red) to ±
D-A90 D-A90V
Suffix for ATEX certified CAT.3
OUT( ) Blue(Black)
Switch No. 93 90
With indicator lamp Without indicator lamp
D-A93, D-A93V Reed switch
LED
Brown(Red)
Resistance
Contact protective box
Zener diode
OUT(+) Brown(Red) to
CD-P11 CD-P12 Blue(Black)
OUT(–) Blue(Black)
Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is “>” 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
46
Electrical entry No number V
In line Perpendicular
Lead wire length No number L Z
0.5m 3m 5m (Except D-A90쐽)
ATEX Compliant Reed Switch/Direct Mounting
D-90A/D-93A-588 Grommet Lead wire: Heavy insulation cable
Specifications D-90A (Without indicator light)
PLC: Programmable Logic Controller
D-90A
Auto switch model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category Application
Relay/IC circuit/PLC 24V AC DC or less
Load voltage Max. load current
50mA
Internal resistance
1Ω or less (Including 3m lead wire)
D-93A (With indicator light) D-93A
Auto switch model number ATEX Category Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Application
Relay/PLC
Load voltage
24V DC 5 to 40mA
Load current range
≤ 2.4V
Internal voltage drop
ON: When red light emitting diode
Indicator light Lead wire
Oilproof vinyl heavy insulation cable, 0.2mm2, 2 cores (Brown, Blue), 0.5m
This category 3 type autoswitch can only be used in zones 2 and 22.
Internal Circuit ( ): If not applicable for IEC Standard D-90A
How to order Reed switch
CD-P11 CD-P12
OUT(±) Brown(Red) to ±
Contact protection box
D-
OUT( ) Blue(Black)
A
-588 Suffix for ATEX certified CAT.3
D-93A Reed switch
Brown (Red)
Contact protection box
Zener diode CD-P11
Resistance LED
CD-P12 Blue (Black)
OUT(+) Brown(Red) to OUT(–) Blue(Black)
Switch No. 93 90
With indicator lamp Without indicator lamp
Lead wire length No number L Z
0.5m 3m 5m
Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is “>” 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
47
ATEX Compliant Reed Switch/Direct Mounting
D-Z73/D-Z80-588 Specifications D-Z7 (With indicator light)
Grommet
PLC: Programmable Logic Controller
D-Z73
Auto swich model number
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
ATEX Category Application
Relay/PLC 24V DC
Load voltage
5 to 40mA
Max. load current and load current range
None
Contact protection circuit
≤ 2.4V (up to 20mA)/≤ 3V (up to 30mA)
Internal voltage drop
ON: When red light emitting diode
Indicator light
D-Z8 (Without indicator light) D-Z80
Auto switch model number ATEX Category
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67 Relay/PLC/IC circuit
Application
24V AC DC or less
Load voltage Max. load current
40mA
50mA None
Contact protection circuit
1Ω or less (Including 3m lead wire)
Internal resistance Lead wire
48V AC DC or less
Oilproof vinyl heavy insulation cable, ø3.4, 0.2mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5m
This category 3 type autoswitch can only be used in zones 2 and 22.
How to order
Internal Circuit ( ): If not applicable for IEC Standard
D-Z
-588
D-Z73 Reed switch
LED Brown(Red) Resistance Zener diode
to
CD-P11
OUT(–) Blue(Black)
CD-P12 Blue(Black)
CD-P11 CD-P12
OUT(±) Brown(Red) to ±
Reed switch
D-Z80 Contact protection box
OUT( ) Blue(Black)
Note) qIn the case operation load is an inductive load. wIn the case the wiring length to “>” 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
48
Suffix for ATEX certified CAT.3
OUT(+) Brown(Red)
Contact protection box
Switch No. 73 80
With indicator lamp Without indicator lamp
Lead wire length No number L Z
0.5m 3m 5m
ATEX Compliant Reed Switch/Direct Mounting
D-E73A/D-E80A-588 Specifications D-E73A (With indicator light)
Grommet
PLC: Programmable Logic Controller
D-E73A
Auto swich model number ATEX Category
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67
Application
Relay/PLC 24V DC
Load voltage
5 to 40mA
Max. load current and load current range Contact protection circuit
None
Internal voltage drop
≤ 2.4V ON: When red light emitting diode
Indicator light
D-E80A (Without indicator light) D-E80A
Auto switch model number ATEX Category
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67 Relay/PLC/IC circuit
Application
24V AC DC or less
Load voltage
50mA
Max. load current
Note) All other specifications (dimensions, drawings, etc.) are the same as the non ATEX type.
40mA None
Contact protection circuit
1Ω or less (Including 3m lead wire)
Internal resistance Lead wire
48V AC DC
Oilproof vinyl heavy insulation cable, ø3.4, 0.2mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5m
This category 3 type autoswitch can only be used in zones 2 and 22.
Internal Circuit ( ): If not applicable for IEC Standard
How to order
D-E73A Reed switch
LED
Brown(Red)
Resistance
Contact protection box
D-E
OUT(+) Brown(Red)
Zener diode
Suffix for ATEX certified CAT.3
OUT(–) Blue(Black)
CD-P12 Blue(Black)
Switch No. OUT(±) Brown(Red) to
73 80
With indicator lamp Without indicator lamp
Lead wire length No number L Z
0.5m 3m 5m (Except D-E80A)
±
Reed switch
D-E80A
CD-P11 CD-P12
-588
to
CD-P11
Contact protection box
A
OUT( ) Blue(Black)
Note) qIn the case operation load is an inductive load. wIn the case the wiring length to load is “>” 5m. Be sure to use the auto switch with the contact protection box in any case mentioned above.
49
Reed Switch/Direct Mounting Type
D-R73/D-R80 Applicable rotary actuator series Size 20, 30, 50, 80, 100 20, 30 7, 20
Series
Grommet Lead Wire: In-line
CDRB1 CDRBU MDSUB
Auto switch specificatoins D-R73쏔 (With indicator light) Auto switch model no. Applicable load Load voltage
D-R731/D-R732
D-쏔쏔쏔1
D-R801/D-R802 Relay, IC circuit, PLC
Relay, PLC 100V AC
Max. load current and 5 to 20mA load current range
D-쏔쏔쏔2
PLC: Programmable Logic Controller
D-R80쏔 (Without indicator light)
24V DC
AC 24V DC or less
AC 48V DC
AC 100V DC
5 to 40mA
50mA
40mA
20mA
Contact protection circuit
None 2.4V or less Internal voltage drop ON: Red light emitting diode Indicator light
None 0 None
Lead wire Oil proof vinyl heavy insulation cable 0.2mm2, X2 wire (Brown, blue) 0.5m Note 1) Refer to p.6-18 for common specifications of reed switch. Note 2) Refer to p.6-18 for lead wire length.
Left hand mounting Right hand mounting
Auto switch internal circuit ( ): Before IEC standard
D-R731/R732
Reed switch
Emitting diode
Brown (Red)
Resistance
Contact protection box
Dimensions D-R731: Right hand mounting
D-R732: Left hand mounting
D-R801: Right hand mounting
D-R802: Left hand mounting
OUT (+) Brown (Red)
~
Zener diode Blue (Black)
CD-P11 CD-P12
OUT (–) Blue (Black)
Reed switch
D-R801/R802
50
Contact protection box CD-P11 CD-P12
OUT (±) Brown (Red)
~ OUT (±) Blue (Black)
Reed Switch/Direct Mounting Type
D-R73쏔C/D-R80쏔C Applicable rotary actuator series Series
Connector Electrical Entry: In-line
Size 20, 30, 50, 80, 100 20, 30 7, 20
CDRB1 CDRBU MDSUB
Auto switch specifications D-R73쏔C ( With indicator light)
D-쏔쏔쏔쏔C
D-쏔쏔쏔쏔C
Auto switch model no. Applicable load Load voltage Load current range
D-R731C/D-R732C Relay, PLC
Contact protection circuit Internal voltage drop Indicator light
None 2.4V or less
PLC: Programmable Logic Controller
D-R80쏔C ( Without indicator light) D-R801C/D-R802C Relay, PLC AC 24V DC or less 50mA
24V DC 5 to 40mA
ON: Red light emitting diode
None 0 None
Lead wire Oil proof vinyl heavy insulation cable ø3.4, 0.2mm2 Note 1) Refer to p.6-18 for common specifications of reed switch. Note 2) Refer to p.6-18 for lead wire length.
Left hand mounting Right hand mounting
Dimensions D-R731C: Right Hand Mounting
D-R732C: Left Hand Mounting
D-R801C: Right hand mounting
D-R802C: Left hand mounting
Auto switch internal circuit ( ): Before IEC standard
D-R731/R732
Reed switch
Emitting diode
Brown (Red)
Resistance
Contact protection box
OUT (+) Brown (Red)
~
Zener diode Blue (Black)
CD-P11 CD-P12
OUT (–) Blue (Black)
Reed switch
D-R801/R802
Contact protection box CD-P11 CD-P12
OUT (±) Brown (Red)
~ OUT (±) Blue (Black)
Specific product precautions Caution Confirm that there is no looseness after wiring. The looseness will decrease water resistance.
51