Preview only show first 10 pages with watermark. For full document please download

Atis Q46t Turbidity Support Drawings

   EMBED


Share

Transcript

Model Q46T Turbidity Analyzer Enclosure Dimensions ANALYZER DIMENSIONS (WALL MOUNT SHOWN) Material: Polycarbonate Ratings: Nema 4X (IP-66) V-0 Fire Retardant ATI-0926 JUNCTION BOX ATI-0655 SS-Q46T, RD (4/15) Page 1 of 12 Model Q46T Turbidity Analyzer Enclosure Mounting Options PIPE MOUNTING ATI-0927 PANEL MOUNTING DIAGRAM ATI-0928 SS-Q46T, RD (4/15) Page 2 of 12 Model Q46T Turbidity Analyzer AIR-BLAST ASSEMBLY SS-Q46T, RD (4/15) Page 3 of 12 Model Q46T Turbidity Analyzer Sensor Options FLOW TYPE SENSOR (63-0109) AUTOCLEAN SENSOR HOLDER (00-1692) w/SENSOR (63-0109) SS-Q46T, RD (4/15) Page 4 of 12 Model Q46T Turbidity Analyzer FLOW TEE EXPLODED VIEW ATI-0542 SS-Q46T, RD (4/15) Page 5 of 12 Model Q46T Turbidity Analyzer IN-LINE INSTALLATION ATI-0513 SS-Q46T, RD (4/15) Page 6 of 12 Model Q46T Turbidity Analyzer STANDARD FLOWCELL (63-0038) Sensor Mounting RAW WATER FLOWCELL (00-1491) NOTE: RAW WATER FLOWCELL TO BE USED FOR HIGH TURBIDITY APPLICATIONS SENSOR HANDRAIL MOUNTING SENSOR HANDRAIL INSTALLATION SUBMERSIBLE SENSOR MOUNTING OPTIONS STANDARD SUBMERSIBLE (00-1690) SS-Q46T, RD (4/15) AUTOCLEAN SUBMERSIBLE (00-0624) Page 7 of 12 Model Q46T Turbidity Analyzer Electrical Connections POWER, RELAY, AND OUTPUT CONNECTIONS Optional Analog Output Wiring Optional Relay Board Wiring (30V Max.) ATI-0930, 0932, 0933 RELAY WIRING TB4,5,6 DETAIL ATI-0931 SS-Q46T, RD (4/15) Page 8 of 12 Model Q46T Turbidity Analyzer Electrical Connections SENSOR CONNECTIONS ATI-1025 SS-Q46T, RD (4/15) Page 9 of 12 Model Q46T Turbidity Analyzer Electrical Connections SENSOR CONNECTIONS - REMOTE JUNCTION BOX ATI-1026 SS-Q46T, RD (4/15) Page 10 of 12 Model Q46T Turbidity Analyzer MONITOR HANDRAIL INSTALLATION Auto-Clean Installation NOTES 1) Always mount sensor cleaner within 25 ft. of sensor if possible. Maximum air line distance is 50 ft. 2) Sun shade over monitor is recommended in hot climates. 3) Monitor Handrail Mounting Kit # 00-0930 supplies all hardware listed for mounting monitor. 4) Wall mounting requires customer supplied screws or bolts. 5) Sensor Pipe Mounting Kit # 00-0624 supplies mounting plate with hardware and PVC pipe mounting adaptor. ATI-0962 SS-Q46T, RD (4/15) Page 11 of 12 Model Q46T Turbidity Analyzer Auto-Clean Interconnections AUTOCLEAN SYSTEM - ELECTRICAL WIRING NOTE: DC ANALYZER PWR INPUTS INDICATE "+" AND "-" FOR INPUT CONNECTIONS. DO NOT ATTEMPT TO CONNECT AC PWR TO A DC ANALYZER AND VISE VERSA NOTE: IF UNITS ARE ORDERED WITHOUT OPTIONAL MOUNTING PLATE w/DISTRIBUTION BOX, THE TRANSMITTER AND Q-BLAST MUST BE WIRED INDIVIDUALLY. ATI-0966 SS-Q46T, RD (4/15) Page 12 of 12