attention This installation manual includes specific instructions for unpacking, positioning the Chase, and hole locations for products being installed. All holes for mounting products should be drilled before installing products. For Product installation refer to instructions packaged with product. Installation must be done in the following order... A) Unpack and bolt chase to floor. B) Mount products to chase. C) Install soffit.
Chase Installation Unpacking and Installation.....................3 thru 9
TP200 Rev. A
Hole Location Information Upper Cabinet................................................ 10 Dressing Nook..................................................... 11 255/354/355 Light...............................12 thru 15 Midmark Dental Light..........................16 thru 19 Vet Vision DC.....................................20 thru 23 VMS/VME Anesthesia Machine and Monitor Mount..................................24 thru 29 VetPro 5000 Delivery..........................30 thru 34 Wet and Dry Peninsula Table......................... 35 Canis Major .......................................36 thru 39 Veterinary Folding Exam Table...........40 thru 47 Laptop Tray.............................................. 48 & 49
Soffit Installation Soffit Installation..........................................50 & 51
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
1
Style A
003-2443-00 Rev. E (12/30/14)
TP200 Rev. A © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
2
Style A
Applies to Models:
Chase Installation
8010 8011 VC (Veterinary Chase)
Special Tools:
Caution
Step Ladder Hammer Drill Drill & Bits for Floor Type Dolly Level
Chase must be mounted securely to the floor. Chase unit weighs 350 lbs (160 kgs), shipping weight 400 lbs (182 kgs). Midmark recommends minimum of two people to move chase unit. Use care when moving to prevent personal injury.
Note
Midmark recommends using a licensed professional to install required plumbing, air and electrical connections for products assembled to the Chase.
Step 1: Install plumbing and air connections.
A) Verify orientation, architectural layout and location of chase installation. B) Mark locations of plumbing, air and mounting holes using templates provided. C) Install plumbing and air connections. Note:
Refer to installation manuals for products that are being mounted to chase for air, water and electrical connection specifications.
TP200 Rev. A
Templates 003-2503-00 & 003-2509-00
Sample EXAMPLE © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
3
Style A
Sales Order and Build Date Label Locations Pentagonal Rectangular
TP200 Rev. A
Plumbing Access Cut-Out
Sales Order: Build Date: Item Number: Description:
10090599 12/24/2014 VC* 123456
Room:
Sales Order: Build Date: Item Number: Description:
Elavation:
Room:
10090599 12/24/2014 VC* 123456
Elavation:
VA1787i
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
4
Style A
Equipment Alert
To prevent damage, do not use tools to remove panel.
Step 2: Remove access panels.
Soffit
A) Pull bottom access panels out. B) Pull bottom of top access panels out, lift top up and out to release. C) Remove soffit (if applicable), top cover, and part bags from inside of chase.
Pentagonal Model Shown Top Cover Top Access Panel Bottom Access Panel
Soffit
Hardware
Rectangular Model Shown Top Cover
Top Access Panel
Bottom Access Panel Hardware
TP200 Rev. A
Panel Clips
Top Access Panel
Bottom Access Panel © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
5
Style A
Caution
Chase unit weighs 350 lbs (160 kgs). Midmark recommends minimum of two people to move unit. Failure to comply may result in personal injury.
Step 3: Position chase unit.
A) Raise chase up onto dolly, aligning floor brace supports with bottom of dolly. B) Verify at least one floor brace is supported by dolly before moving. C) Using architectural layout verify orientation of cabinet. D) Position chase over air and plumbing connections.
Floor Brace Supports Pentagonal Model Shown
TP200 Rev. A
Rectangular Model Shown Floor Brace Supports
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
6
Style A
Step 4: Mount and level Chase unit. A) B) C)
Drill six holes into floor through floor brace support mounting holes. Use appropriate drill for floor material. Install mounting bolts at six locations. Verify chase unit is level and all bolts, mounting and leveling are tightened. Refer to leveling procedure if necessary..
Rectangular Model Shown
Level
Adjusting Bolt
Support Bolts Mounting Bolt
Support Bolts
Adjusting Bolt
Mounting Bolt
TP200 Rev. A
Pentagonal Model Shown
Leveling Procedure
A) Loosen support bolts. B) Loosen / tighten thread to adjust. Right to lower, left to raise. C) Tighten support bolts. Note: There are four leveling assemblies on both models of chase cabinets.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
7
Style A
Note
There are two different sides to the chase unit for each model. Sides will be referred as “Fixed side” and “Removable side”. Use this page to help you identify sides.
Pentagonal Model
TP200 Rev. A
Fixed Side (2 sides)
Rectangular Model
Fixed Side (2 sides)
Removable Side (1 side)
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
8
Removable Side (2 sides)
Style A
Caution - Equipment Alert
Keep hands clear from front of panels when drilling holes.
Step 5: Mount products to chase. A) B) C) D)
Refer to the following pages for each product’s mounting location on rectangular and pentagonal models. Drill mounting holes in chase typically from the inside. Drill fixed sides first, then removable sides. Drill holes for all products that will be mounted, then refer to product manual for other product installation steps. Install access panels. Continue with Step 6 after mounting products to chase unit.
TP200 Rev. A
Note: Install products starting with the ones located closest to the top of the chase and work your way down, on the sides without access panels (“Fixed Sides” do not have access panels). Drill product mounting holes from inside chase so you are aligned with holes in the metal frame. Install tables last.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
9
Style A
Upper Cabinet Installation on Pentagonal or Rectangular on Removable OR Fixed Side A) B) C) D) E) F) G)
Install access panels. Center hanging bracket on panel, side to side. Note: Hole locations vary depending on width of hanging bracket / cabinet. Drill minimum of four, 3/16” holes from inside of chase. Mount hanging bracket with screws (#10 1-1/4”), washers, and nuts. Hang cabinet onto hanging bracket. Secure bottom of cabinet using wood screws. Door adjustments refer to modular casework installation manual.
Nut Washer
Note: Hardware for mounting is provided with chase.
Access Door Not Shown Hanging Bracket #10 (1-1/4”) Screw
Washer
VA1761i
24” Upper Cabinet Shown TP200 Rev. A
Access Door Not Shown
Wood Screw © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
10
Style A
VA1785i
Dressing Nook Installation on Pentagonal or Rectangular on Removable OR Fixed Side
TP200 Rev. A
A) B) C) D) E) F) G)
Install access panels. Center hanging bracket on panel, side to side. Note: Hole locations vary depending on width of hanging bracket / nook. Drill minimum of four, 3/16” holes from inside of chase. Mount hanging bracket with screws (#10 1-1/4”), washers, and nuts. Hang nook onto hanging bracket. Secure bottom of nook using wood screws. Door adjustments refer to modular casework installation manual.
Note: Hardware for mounting is provided with chase.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
11
Style A
255 / 354 / 355 Light to Chase (Removable Side Installation on Pentagonal) A) B) C) D)
Install access panels. Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to your Light‘s Installation Manual for mounting to wood instructions.
Access Door Not Shown for Clarity
355 Light Shown
TP200 Rev. A
Mounting Hardware is Provided with Light
Access Door Not Shown for Clarity To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
12
Style A
255 / 354 / 355 Light to Chase (Fixed Side Installation on Pentagonal)
A) B) C) D) E)
Drill three,13/32” holes from inside, on the 90 degree corner mounting side, aligned with holes in metal frame. Measure over from center of drilled holes 16” and mark. Measure distance down from top of chase to drilled holes. Verify distance from top of chase to marks are the same measurement from top to drilled holes. Drill three 13/32” holes at marked locations from front of panel on door mounting side. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to your Light‘s Installation Manual for mounting to wood instructions..
Note: There is no access for a drill behind the door side. Must measure over from first set of holes and drill from front.
Access Door Not Shown for Clarity
Access Door Not Shown for Clarity
16
”
355 Light Shown Door Mounting Side To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out
TP200 Rev. A
Mounting Hardware is Provided with Light
90 Degree Corner Mounting Side Drill First © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
13
Style A
255 / 354 / 355 Light to Chase (Removable Side Installation on Rectangular)
TP200 Rev. A
A) B) C) D)
Install access panel on side you are drilling in. Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to your Light‘s Installation Manual for mounting to wood instructions.
Mounting Hardware is Provided with Light
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
14
Style A
255 / 354 / 355 Light to Chase (Fixed Side Installation on Rectangular)
A) Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. B) Cut square opening in wood panel of chase to conceal light power cord. (optional) C) Refer to your Light‘s Installation Manual for mounting to wood instructions.
TP200 Rev. A
355 Light Shown
Mounting Hardware is Provided with Light
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
15
Style A
Midmark Dental Light to Chase (Removable Installation on Pentagonal) A) B) C) D)
Install access panels. Drill four, 13/32” holes from inside so you are aligned with holes in metal frame. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to Midmark Dental Light installation manual, wall mount instructions. Access Door Not Shown for Clarity
Midmark Dental Light Shown
TP200 Rev. A
Mounting Hardware is Provided with Chase
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
16
Style A
Access Door Not Shown for Clarity
Midmark Dental Light to Chase (Fixed Side Installation on Pentagonal) A) B) C) D) E)
Drill two,13/32” holes from inside, on the 90 degree corner mounting side, aligned with holes in metal frame. Measure over from center of drilled holes 16” and mark. Measure distance down from top of chase to drilled holes. Verify distance from top of chase to marked locations are the same measurement from top to drilled holes. Drill three 13/32” holes at marked locations on door mounting side. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to Midmark Dental Light installation manual, wall mount instructions.
Note: There is no access for a drill behind the door side. Must measure over from first set of holes and drill from front.
Access Door Not Shown for Clarity
Midmark Dental Light Shown
Access Door Not Shown for Clarity
16
”
Door Mounting Side
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out
TP200 Rev. A
Mounting Hardware is Provided with Chase
90 Degree Corner Mounting Side Drill First © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
17
Style A
Midmark Dental Light to Chase (Removable Side Installation on Rectangular) A) B) C) D)
Install access panel on side you are drilling in. Drill four, 13/32” holes from inside so you are aligned with holes in metal frame. Cut square opening in wood panel of chase to conceal light power cord. (optional) Refer to Midmark Dental Light installation manual, wall mount instructions.
Midmark Dental Light Shown
TP200 Rev. A
Mounting Hardware is Provided with Chase
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
18
Style A
Midmark Dental Light to Chase (Fixed Side Installation on Rectangular)
A) Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. B) Cut square opening in wood panel of chase to conceal light power cord. (optional) C) Refer to Midmark Dental Light installation manual, wall mount instructions.
Midmark Dental Light Shown
TP200 Rev. A
Mounting Hardware is Provided with Chase
To Conceal Power Cord, Route thru 1 5/8” x 2 1/2” Cut-out © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
19
Style A
Vet Vision DC to Chase (Removable Side Installation on Pentagonal)
A) Install access panels. B) Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. C) Refer to Vet Vision DC installation manual for mounting instructions.
Access Doors Not Shown for Clarity
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
20
Style A
Vet Vision DC to Chase (Fixed Side Installation on Pentagonal) A) B) C) D)
Drill three, 13/32” holes from inside, on the 90 degree corner mounting side, aligned with holes in metal frame. Measure over from center of drilled holes 16” and mark. Measure distance down from top of chase to drilled holes. Verify distance from top of chase to marked locations are the same measurement from top to drilled holes. Drill three 13/32” holes at marked locations on door mounting side. Refer to Vet Vision DC installation manual for mounting instructions.
Note: There is no access for a drill behind the door side. Must measure over from first set of holes and drill from front.
Access Door Not Shown for Clarity
TP200 Rev. A
Mounting Hardware is Provided with Chase
Access Door Not Shown for Clarity
90 Degree Corner Mounting Side Drill First © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
21
Style A
Vet Vision DC to Chase (Removable Side Installation on Rectangular) A) Install access panels on side you are drilling. B) Drill six, 13/32” holes from inside so you are aligned with holes in metal frame. B) Refer to Vet Vision DC installation manual for mounting instructions.
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
22
Style A
Vet Vision DC to Chase (Fixed Side Installation on Rectangular)
A) Drill six, 13/32” holes from inside, so you are aligned with holes in metal frame. B) Refer to Vet Vision DC installation manual for mounting instructions.
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
23
Style A
VMS,VME Anesthesia Machine or Monitor to Chase (Removable Side Installation on Pentagonal) A) B) C) D) E) F) D)
Verify with user if they want unit to be left hand or right hand mounted for VMS or Monitor models. Install access panel. Mark holes with pencil from inside chase. Remove panels. Drill two 11/32” holes on pencil marks. Install panel on chase. Refer to Midmark Anesthesia or Monitor installation manual, wall mount instructions.
VME
Note: Refer to drawing below for VMS, VME, and Monitor hole locations.
VMS
VMS or Monitor Left Hand Mount Location ®
Ve
ter ina
ry Mo nito
r
Monitor
Mounting Hardware is Provided with Chase
TP200 Rev. A
VMS or Monitor Right Hand Mount Location
Access Doors Not Shown for Clarity
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
24
Style A
Mounting Hardware is Provided with Chase
VME
VME Anesthesia Machine to Chase (Fixed Side Installation on Pentagonal) A) B) C) D) E)
Drill one 11/32” hole from inside, on the 90 degree corner mounting side, aligned with holes in metal frame. Measure over from center of drilled holes 16” and mark. Verify distance from top of chase to mark is the same measurement from top to drilled hole. Drill one 11/32” hole at marked location from front of panel on door mounting side. Refer to Midmark Anesthesia installation manual, wall mount instructions.
90 Degree Corner Drill First
Note: There is no access for a drill behind the door side. Must measure over from first set of holes and drill from front. Refer to drawing for VME hole locations.
TP200 Rev. A
Door Mounting Side
Access Doors Not Shown for Clarity
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
25
Style A
VMS Anesthesia Machine or Monitor to Chase (Fixed Side Installation on Pentagonal) For 90 Degree Corner Side installation of VMS or Monitor... A) B) C)
Verify with user if they want unit to be Door side or 90 Degree corner side mounted. Door side installation is on next page. Drill two 11/32” holes from inside so you are aligned with holes in metal frame. Refer to Midmark Anesthesia or Monitor installation manual, wall Mount instructions.
Note: Refer to drawing for VMS or Monitor hole locations.
90 Degree Corner Side Mount Location
VMS
®
Ve
ter
ina
ry Mo
nito
r
TP200 Rev. A
Monitor
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
26
Style A
VMS Anesthesia Machine or Monitor to Chase (Fixed Side Installation on Pentagonal) For Door Side installation of VMS or Monitor... A) B) C)
Measure down from top of panel and mark at 33 1/2” and 39 3/16” at 4 5/32” from side. Drill two 11/32” holes at marked locations. Refer to Midmark Anesthesia or Monitor installation manual, wall mount instructions.
Door Side Mount Location
Note: Refer to drawing below for hole locations.
VMS
®
Ve
ter
ina
ry Mo
nito r
Monitor
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
27
Style A
VMS, VME Anesthesia Machine or Monitor to Chase (Removable Side Installation on Rectangular) A) B) C) D)
VME
Verify with user if they want unit to be left hand or right hand mounted. Install access panel on side you are drilling in. Drill two 11/32” holes from inside so you are aligned with holes in metal frame. Refer to Midmark Anesthesia or Monitor installation manual, wall mount instructions.
Note: Refer to drawing below for VMS, VME and Monitor hole locations.
VMS
Left Hand Mount Location
®
Ve ter ina ry Mo nito r
Monitor
Mounting Hardware is Provided with Chase
TP200 Rev. A
Right Hand Mount Location
VA1744i
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
28
Style A
VMS, VME Anesthesia Machine or Monitor to Chase (Fixed Side Installation on Rectangular) A) B) C)
Verify with user if they want unit to be left hand or right hand mounted. Drill two 11/32” holes from inside so you are aligned with holes in metal frame. Refer to Midmark Anesthesia or Monitor installation manual, wall mount instructions.
VME
Note: Refer to drawing below for VMS, VME and Monitor hole locations.
VMS
Left Hand Mount Location ®
Ve
ter ina
ry Mo
nito
r
Monitor
Mounting Hardware is Provided with Chase
TP200 Rev. A
Right Hand Mount Location
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
29
Style A
Access Door Not Shown for Clarity VetPro 5000 Cabinet Mount Shown
VetPro 5000 to Chase (Removable Side Installation on Pentagonal) A) B) C) D)
Verify with user if they want unit to be left hand or right hand mounted. Install access panel. Drill four, 5/16” holes from inside so you are aligned with holes in metal frame. Refer to VetPro 5000, cabinet installation manual.
Left Hand Mount Location
Access Door Not Shown for Clarity Right Hand Mount Location
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
30
Style A
VetPro 5000 to Chase For Right Hand Side installation (Fixed Side Installation on Pentagonal)
A) Verify with user if they want unit to be left hand or right hand mounted. Left mounted is on next page. C) Drill four 5/16” holes from inside so you are aligned with holes in metal frame. D) Refer to Midmark Anesthesia installation manual, wall mount instructions.
Access Door Not Shown for Clarity
Note: Drill is able to access this hole pattern from inside chase at the 90 degree corner.
VetPro 5000 Cabinet Mount Shown
Right Hand Mount Location
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
31
Style A
VetPro 5000 to Chase For Left Hand Side installation (Fixed Side Installation on Pentagonal) A) B) C)
Measure down from top of panel and mark a line at 59 1/2” and 4 7/8” from the side of chase. Measure over 3 5/8” and make another mark. Repeat at 51 1/2” from top. Drill four, 5/16” holes at marked locations from outside the chase. Refer to VetPro 5000, cabinet installation manual.
Left Hand Mount Location
Mounting Hardware is Provided with Chase
TP200 Rev. A
VetPro 5000 Cabinet Mount Shown
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
32
Style A
VetPro 5000 to Chase (Removable Side Installation on Rectangular)
A) B) C) D)
Verify with user if they want unit to be left hand or right hand mounted. Install access panel on side you are drilling in. Drill four, 5/16” holes from inside so you are aligned with holes in metal frame. Refer to VetPro 5000, cabinet installation manual.
VetPro 5000 Cabinet Mount Shown Left Hand Mount Location
Right Hand Mount Location
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
33
Style A
VetPro 5000 to Chase (Fixed Side Installation on Rectangular)
VetPro 5000 Cabinet Mount Shown
A) Verify with user if they want unit to be left hand or right hand mounted. B) Drill four, 5/16” holes from inside so you are aligned with holes in metal frame. C) Refer to VetPro 5000, cabinet installation manual.
Left Hand Mount Location
Right Hand Mount Location
TP200 Rev. A
Mounting Hardware is Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
34
Style A
Wet or Dry Peninsula Table (All Sides) A) B) C) D)
Hole Locations - All Models
Install filler panel on both sides of table. Center table against chase panel. Level table per table installation instructions. Drill four, 3/16” holes from inside of table, which will locate in slotted holes. Refer to Midmark Wet or Dry Treatment Table installation manual, casework (flush mount) and wall mount instructions.
Wet Peninsula Table
Provided With Table
VA1751i
TP200 Rev. A
Mounting Hardware is Provided with Chase Filler Panel
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
35
Style A
Canis Major to Chase (Removable Side Installation on Pentagonal) (Step A for Wet Tables ONLY)
TP200 Rev. A
A) Install water inlet manifold (installer supplied). Saw opening at 44” from floor. B) Refer to Canis Major Wet / Table installation manual for instructions.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
36
Style A
Canis Major to Chase (Fixed Side Installation on Pentagonal) (Step A for Wet Tables ONLY)
TP200 Rev. A
A) Install water inlet manifold (installer supplied). Saw opening at 44” from floor. B) Refer to Canis Major Wet / Table installation manual for instructions.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
37
Style A
Canis Major to Chase (Removable Side Installation on Rectangular) (Step A for Wet Tables ONLY)
TP200 Rev. A
A) Install water inlet manifold (installer supplied). Saw opening at 44” from floor. B) Refer to Canis Major Wet Table installation manual for instructions to connect water to table.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
38
Style A
Canis Major to Chase (Fixed Side Installation on Rectangular) (Step A for Wet Tables ONLY)
TP200 Rev. A
A) Install water inlet manifold (installer supplied). Saw opening at 44” from floor. B) Refer to Canis Major Wet Table installation manual for instructions to connect water to table.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
39
Style A
Equipment Alert
If Bottom four mounting holes are present in steel frame of Pentagonal Chase cabinet, refer to the next page for instructions.
Veterinary Folding Exam Table to Chase (Removable Side Installation on Pentagonal) A) B) C) D)
Install bottom access panel. Drill top two holes, 13/32”, toward the top of the slots, from inside the chase. Ensure locations of holes are level to each other. From outside of chase, measure down 4 3/8” from drilled holes to locate second set of holes. Measure down 4 3/8” from this marked location to locate bottom set of holes. Drill bottom four holes, 13/32”, at marked locations. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
Mounting Hardware Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
40
Style A
Equipment Alert
If Bottom four mounting holes are not present in steel frame of Pentagonal Chase cabinet, refer to the previous page for instructions.
Veterinary Folding Exam Table to Chase (Removable Side Installation on Pentagonal) A) B) C) D)
Install bottom access panel. Drill bottom four holes, 13/32”, from inside so you are aligned with holes in metal frame. Measure up 4 3/8” from drilled holes to locate top two holes. Drill two 13/32” holes within slot area. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
Mounting Hardware Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
41
Style A
Equipment Alert
If Bottom four mounting holes are present in steel frame of Pentagonal Chase cabinet, refer to the next page for instructions.
Veterinary Folding Exam Table to Chase (Fixed Side Installation on Pentagonal) A) B) C)
Drill top two holes, 13/32”, toward the top of the slots, from inside the chase. Ensure locations of holes are level to each other. From outside of chase, measure down 4 3/8” from drilled holes to locate second set of holes. Measure down 4 3/8” from this marked location to locate bottom set of holes. Drill bottom four holes, 13/32”, at marked locations. Refer to Veterinary Folding Exam Table installation manual.
Mounting Hardware Provided with Chase
Access Door Not Shown for Clarity
TP200 Rev. A
Veterinary Folding Exam Table Shown
90 Degree Corner Mounting Side Drill First © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
42
Style A
Mounting Hardware Provided with Chase
Equipment Alert
If Bottom four mounting holes are not present in steel frame of Pentagonal Chase cabinet, refer to the previous page for instructions.
Veterinary Folding Exam Table to Chase (Fixed Side Installation on Pentagonal)
A) Drill bottom four holes, 13/32”, from inside so you are aligned with holes in metal frame. B) Measure up 4 3/8” from drilled holes to locate top two holes. Drill two 13/32” holes within slot area. C) Refer to Veterinary Folding Exam Table installation manual. Note: Drill is able to access this hole pattern from inside chase at the 90 degree corner. However, there is no access for a drill behind the door side. Must measure over from first set of holes and drill from front.
Access Door Not Shown for Clarity
TP200 Rev. A
Veterinary Folding Exam Table Shown
90 Degree Corner Mounting Side Drill First © 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
43
Style A
Equipment Alert
If Bottom four mounting holes are present in steel frame of Rectangular Chase cabinet, refer to the next page for instructions.
Veterinary Folding Exam Table to Chase (Removable Side Installation on Rectangular) A) B) C) D)
Install bottom access panel. Drill top two holes, 13/32”, toward the top of the slots, from inside the chase. Ensure locations of holes are level to each other. From outside of chase, measure down 4 3/8” from drilled holes to locate second set of holes. Measure down 4 3/8” from this marked location to locate bottom set of holes. Drill bottom four holes, 13/32”, at marked locations. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
Mounting Hardware Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
44
Style A
Equipment Alert
If Bottom four mounting holes are not present in steel frame of Rectangular Chase cabinet, refer to the previous page for instructions.
Veterinary Folding Exam Table to Chase (Removable Side Installation on Rectangular) A) B) C) D)
Install bottom access panel. Drill bottom four holes, 13/32”, from inside so you are aligned with holes in metal frame. Measure up 4 3/8” from drilled holes to locate top two holes. Drill two 13/32” holes within slot area. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
Mounting Hardware Provided with Chase
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
45
Style A
Mounting Hardware Provided with Chase
Equipment Alert
If Bottom four mounting holes are present in steel frame of Rectangular Chase cabinet, refer to the next page for instructions.
Veterinary Folding Exam Table to Chase (Fixed Side Installation on Rectangular) A) B) C)
Drill top two holes, 13/32”, toward the top of the slots, from inside the chase. Ensure locations of holes are level to each other. From outside of chase, measure down 4 3/8” from drilled holes to locate second set of holes. Measure down 4 3/8” from this marked location to locate bottom set of holes. Drill bottom four holes, 13/32”, at marked locations. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
46
Style A
Mounting Hardware Provided with Chase
Equipment Alert
If Bottom four mounting holes are not present in steel frame of Rectangular Chase cabinet, refer to the previous page for instructions.
Veterinary Folding Exam Table to Chase (Fixed Side Installation on Rectangular) A) B) C)
Drill bottom four holes, 13/32”, from inside so you are aligned with holes in metal frame. Measure up 4 3/8” from drilled holes to locate top two holes. Drill two 13/32” holes within slot area. Refer to Veterinary Folding Exam Table installation manual.
TP200 Rev. A
Veterinary Folding Exam Table Shown
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
47
Style A
Laptop Tray to Chase (Fixed Side Installation on Pentagonal)
A) Find bottom center hole in frame. B) Drill hole from inside Chase using a 5/16” drill bit through hole in frame and panel. C) Use a level to measure down 4-1/2” and drill second hole. D) Refer to Laptop Tray installation manual.
TP200 Rev. A
Mounting Hardware is Provided with Tray
VA1819i
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
48
Style A
Laptop Tray to Chase (Installation on Panels)
A) Locate center of panel. B) Drill top hole at 27-3/4 from floor using a 5/16” drill bit. C) Use a level to measure down 4-1/2” and drill second hole. D) Refer to Laptop Tray installation manual.
TP200 Rev. A
Mounting Hardware is Provided with Tray
VA1820i
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
49
Style A
Install Soffit - for Rectangular Chase Step 6: Install top panel and soffit around utilities supplied through ceiling. A) B) C) D)
Install top panel by bending split and maneuvering around the utilities dropping from ceiling. Screw top panel to the chase and install angle brackets onto the top panel. Screw soffits onto the angle brackets. Fit the soffit covers together and screw in place surrounding the utilities supplied from the ceiling.
Utilities
Note: Soffit assembly parts for 8010 Model are slightly different than shown here but installation will be similar.
Top Panel
Chase Soffit
A) Angle Brackets (4) Top Panel for Chase with utilities supplied through the floor
TP200 Rev. A
Solid Top Panel
B)
C)
D)
Note:
Soffit may need to be secured to ceiling to prevent it from flexing or shifting. Midmark recommends two people for soffit installation.
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
50
Style A
Install Soffit - for Pentagonal Chase Step 6: Install top panel and soffit around utilities supplied through ceiling. A) B) C) D)
Break apart the top panel and screw one half to the top of the chase. Screw the second half of the top panel onto the chase*. Install angle bracket(s) onto the top panel. Install the soffit covers to surround the utilities routed down from the ceiling.
Top Panel
Utilities
* Study how the soffit assembly pieces will fit against the ceiling and install them in the order that works best for this installation. You may have to vary from the order shown here. Note: Soffit assembly parts for 8011 Model are slightly different than shown here but installation will be similar.
Chase
A)
Soffit
Top Panel for Chase with utilities supplied through the floor
Angle Brackets (3)
TP200 Rev. A
Solid Top Panel
C)
B)
D)
Note:
Soffit may need to be secured to ceiling to prevent it from flexing or shifting. Midmark recommends two people for soffit installation.