Preview only show first 10 pages with watermark. For full document please download

Austin Hughes Infrapower Single Phase Wi Monitored Kwh Outlet

   EMBED


Share

Transcript

PDU specification drawing Date : 1 Jan 16 Version : V2 1-Phase 230V 32A monitored PDU + outlet measurement : C13 x 30 + C19 x 6 1775mm Circuit B C4 C6 Resettable fuse 26mm C6 C4 C2 30 C2 28 30 26 28 24 26 22 22 20 24 18 20 16 18 14 16 12 14 10 10 12 8 8 6 6 4 4 A 1 3 5 7 9 11 13 17 15 19 21 23 25 27 29 C1 C5 C3 C1 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 1 x IP Dongle allows access to 16 levels M 3.58 226.2 TH 2 31.7 15.9 15.8 Main TH 1 For IP PDU access simply connect 1 x IP dongle kW Volt Access The PDU can be cascaded up to 16 levels Amp A B PDU Cascade functionality and Remote LINK 85 OUT B 2 2 C3 C5 Circuit A 3m IEC 60309 32A 2P+E PLUG MCB MCB or fuse : refer to the models below 32A model : Fuse MCB V30C13/6C19-32A-Wi/F_EN/3B-2 2 - V30C13/6C19-32A-Wi/CR_EN/3B-2 - 2 Input Rating Inlet Cordset Protection Circuit Details : : : : : 32A, 230V 32A IEC60309 2P+E plug 3 meter 4mm sq. H05V V-F cordset 16A resettable fuse or 16A hydraulic MCB x 2 < Circuit A > Output 16A max. C 1 3 # 1 - 2 9 ( o d d ) + C 1 9 # C 1 , C 3 , C 5 < Circuit B > Output 16A max. C 1 3 # 2 - 3 0 ( e v e n ) + C 1 9 # C 2 , C 4 , C 6 Single phase monitored PDU + outlet measurement Meter Features ( Wi Monitored PDU + Outlet Measurement ) Outlet : 10A Rated IEC320 C13 x 30 Local Display : Field replaceable 2.8” color LCD with touchscreen Bank Measurement : Current ( A ), Energy ( kWh ), Voltage ( V ) & Power factor 16A Rated IEC320 C19 x 6 Outlet Measurement : Current ( A ), Energy ( kWh ) The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication. Copyright 2016 Austin Hughes Electronics Ltd. All rights reserved. Accuracy : ±1% true RMS IP Access : via IP dongle, one IP Access up to 16 PDU Levels Cascade : Up to 16 PDU under single IP address via IP dongle SNMP : via IP dongle Sensor Port x 2 : Temp. Sensor / Temp. + Humid. Sensor EMC Compliance Safety Compliance Environment Compliance Operating Storage Operating Storage Humidity Dimension Material Color Temperature Temperature Altitude Altitude : : : FCC & CE certified CE / LVD certified RoHS2 & REACH : : : : : -5 to 60 °C -25 to 65 °C 0 to 2,000 m 0 to 15,000 m 8 to 95% RH, non-condensing : : : 85 (W) x 90 (D) x 1775 (H) mm Steel White ( outlet bracket ) Black ( chassis )