Aution Micro Operating Manual

   EMBED


Share

Transcript

Compact Urine Analyzer Operating Manual DOC. No. OM-28373 REV.5 06/05 AUTION MICRO PU-4210 OPERATING MANUAL Premise This manual contains important information on the functions of the AUTION MICRO PU-4210. Supplied by : ARKRAY, Inc. distributed by : A. Menarini I.F.R. srl Diagnostic Division This manual has been issued by: ARKRAY, Inc. Read carefully prior to starting up the instrument. It is recommended to retain this manual for future use. This product conforms to European Directive 98/79/EC. e 1 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.5 06/05 Introduction This manual contains outlines, instructions for the operation, maintenance and troubleshooting for the AUTION MICRO PU-4210. Read this manual carefully before use the Analyzer in order to operate it correctly. After you read the manual, keep it near the Analyzer to refer to it when necessary. This instrument uses urine as a sample. Urine may be contaminated by pathogenic microbes that cause infectious diseases. Always be careful when handling urine samples. If operated incorrectly, there is a danger of infection to you and those around you by pathogenic microbes. ● Never touch places where samples may be contacted with bare hands. When you perform maintenance, always wear protective gloves to prevent exposure to pathogenic microbes. ● Separate used Test Strips, etc. from general waste and dispose of them according to local regulations on biohazardous waste. ● ● This instrument may become infectious in the course of use. Discard the product in accordance with local regulations for biohazardous waste. e AUTION MICRO 2 DOC. No. OM-28373 REV.5 06/05 AUTION MICRO PU-4210 OPERATING MANUAL Caution Marks Pay careful attention to these caution marks in this Operating Manual. Regarding accidents resulting injury. To prevent infection of operator or others from pathogenic microbes, follow the instructions described. To prevent injuries to operator or others, or material damages, follow the instructions described. Regarding damage and performance of Analyzer. Important Note Reference Failure to follow the instructions may lead to incorrect results. To prevent damage to the unit and assist you in making best use of the capabilities of the Analyzer, additional explanations and notes are provided herein. Reference information on operation, additional explanations and related functions are provided herein. e 3 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Precautions for Installation ■For installation, read the following precautions carefully and always follow safety measures. ● Place the Analyzer on a stable and level surface, free of vibration. ●Do NOT place the Analyzer where it may be affected by chemicals, corrosive gases and electronic noise. ●Select a room in which to set up the Analyzer where the temperature can be controlled between 10℃ and 30℃, and humidity in a range of 20 to 80 %. ●Do NOT place the Analyzer where it may be affected by direct sunlight or wind. ●Do NOT place the Analyzer where it may be affected by magnetic materials including magnets or speakers. AUTION MICRO 4 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Precautions for Installation ●Plug in an exclusive AC adapter. ●When the instrument is not in use, unplug the AC adapter. ●Should the Analyzer stop functioning, contact your distributor for repairs. Do NOT attempt to repair it your self. Doing so may result in damaging the Analyzer or injury. ●If an abnormal sound, odor or smoke is found, turn the power off immediately and consult your distributor after making sure that the abnormal situation is not continuing. ●Do NOT place the Analyzer where it may be affected by water. Samples may cause damage to the Analyzer. ●Do NOT drop or hit the Analyzer. 5 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Table of Contents AUTION MICRO(PU-4210)Operating Manual Premise …………………………………………………………1 Introduction ……………………………………………………2 Caution Marks …………………………………………………3 Precautions for Installation …………………………………4 Table of Contents ……………………………………………6 Introduction Outline of AUTION MICRO …………………………………7 Shipping Carton ………………………………………………8 Parts Description and Functions ……………………………9 Display Screen and Key Arrangement ……………………10 Measurement Flow of Measurement ………………………………………11 Cautions ………………………………………………………12 Start Up ………………………………………………………14 Setting Up Parameters ……………………………………15 Normal Measurement ………………………………………16 Check Measurement ………………………………………19 Auxiliary Function ……………………………………………21 Special Parameters …………………………………………26 Printing Printer …………………………………………………………27 Printing Item …………………………………………………28 Maintenance and Maintenance …………………………………………………29 Troubleshooting ………………………………………………30 Troubleshooting AUTION MICRO 6 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Outline of PocketChem UA Introduction The AUTION MICRO (PU-4210) is a small portable urine-analyzing device which anyone can use anytime, anywhere. Since the Printer is removed from the Analyzer, you can operate it by a minimal key operation. The device is equipped with transmission capability to adapt to systematization. Characteristics Minimum Maintenance The only necessary maintenance item is cleaning the Strip Holder. Long Life Light Source Use of LED and short-time lighting enables a longer light source life. Temperature Correction Function An automatic correction function, which is provided by the internal thermal sensor, solves any errors caused by temperature changes in the environment. Power Source Use a dry battery or a AC adapter when using the Analyzer alone, and use the AC adapter when using it with a Printer. Regent Selection AUTION Sticks 10EA and Uriflet 9UB are available to use. 100 memories Maximum 100 measurement results can be stored. When more than 100 samples have been measured, older data will be automatically deleted in order. 7 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Shipping Carton Introduction Shipping carton of AUTION MICRO (PU-4210) contains the following. Make sure that all of the following are included: Analyzer Printer AC Adapter     Check Strip Set  Thermal Printer Paper  Operating Manual (this booklet) Compact Urine Analyzer Operating Manual Optional Accessories RS-232C Cable Optional Consumables Thermal Printer Paper    Check Strip Set Strip Holder AUTION MICRO 8 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Parts Description and Functions Introduction Parts description in this Operating Manual is as follows: Front 8 1 2 3 9 Bottom (Analyzer) Rear (Analyzer) 5 6 7 4     Name          Function ① Display Screen Displays measurement results and error codes ② Operator Panel For setting conditions and starting measurement ③ Optical System Measures samples ④ Power Input Terminal For connection of exclusive AC adapter ⑤ Connection Terminal For electrical connection to the Printer ⑥ DATA OUT Terminal Terminal for connection to a PC or other devices ⑦ Battery Box Place batteries here ⑧ FEED key Feeds printer paper ⑨ Lock Release Button Unlocks connection between the Analyzer and Printer 9 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Display Screen and Key Arrangement Introduction LCD 1. Memory 5. Date 4. Delete 2. ID 6. Time 3. No. 7. Test Strip 10. figure display 13 digits 8. Semiquantitative Symbol 9. Item Name 15. Battery Icon 11. Test Strip Icon 14. Printer Icon 13. Transmission Icon 12. Waiting Icon 1. Memory Displayed when the data is redisplayed. 2. ID Displayed (Blinks during ID setting) when ID is displayed. 3. No. Displayed (Blinks during No. setting) when No. is displayed. 4. Delete Blinks when the memory is deleted. For deletion, enter [ENT]. 5. Date Light is on (Blinks during Date setting) when the Date is displayed. 6. Time Light is on (Blinks during Time setting) when the Time is displayed. 7. Test Strip Displayed when the Test Strip type is displayed. Blinks during Test Strip type setting. 8. Semiquantitative Symbol Displayed according to measurement results when measurement results are displayed or redisplayed. 9. Item Name Displayed according to test items when measurement results are displayed or redisplayed. 10. Figure display 13 digits Measurement No., ID, Date, Time, Test Strip name, etc. are displayed. (13 digits) 11. Test Strip Icon Blinks when the Test Strip is dipped or the Test Strip Holder is moved. 12. Waiting Icon Displayed from the measurement start to finish. 13. Transmission Icon Displayed for the external output. 14. Printer Icon Displayed when printing is performed. 15. Battery Icon Displayed in three different signs depending on the degree of exhaustion. Key Arrangement Specification 1. Function Key or Numeric Key 2. Start Key, Enter Key or Power Switch 3. Stop Key or Hyphen Key AUTION MICRO 10 DOC. No. OM-28373 REV.5 06/05 AUTION MICRO PU-4210 OPERATING MANUAL Flow of Measurement Measurement Wear protective gloves to prevent exposure to pathogenic microbes. Separate used test papers, etc. from general waste and dispose of them according to local regulations on biohazardous waste. Flow chart of measurement The following flow chart explains a measurement procedure. Before measurement, understand the whole procedure. Turn on the main power. Enter Measurement No. and Patient ID. Select Test Strip Type Start Measurement Dip the Test Strip in the sample for 2 seconds in accordance with the alarm. Remove the excess sample. Set the Test Strip onto the Strip Holder. The Strip Holder moves inside of the Analyzer and measurement starts. Measurement Results are displayed and the Strip Holder comes out from the Analyzer. Continue measurement Dispose of Test Strip. Finish measurement Clean the Strip Holder, and turn off the main power. e 11 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL Cautions DOC. No. OM-28373 REV.0 04/01 Measurement Handling Samples ● Wear protective gloves to prevent exposure to pathogenic microbes. ● Use a fresh urine sample. If the sample urine is not measured within an hour after collection, cap it tightly and keep it refrigerated. Be sure to allow it to reach to room temperature before measurement. ● Mix the sample thoroughly before measurement. Do NOT centrifuge them. ● Prepare an adequate amount of samples so that the whole pad portion of the Test Strip can be immersed. ● Do NOT add any preservative, disinfectant, or detergent to the sample. ● Keep the sample out of direct sunlight. ● If samples containing ascorbic acid are measured, the measured values of glucose and occult blood are occasionally lower than the real values. ● If drug-administered urine or visually observed hematuria are measured, correct measurement results sometimes cannot be obtained. AUTION MICRO 12 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Cautions Measurement Handling Test Strips ● Do NOT use Test Strips of other manufacturers. Use only our Test Strips,“AUTION Sticks, Uriflet” . Read the attached manuals of the Test Strips. ● Do NOT use expired Test Strips. Do NOT use expired Test Strips and/or Test Strips if the reagent pads show any signs of discoloration, deformation or deterioration. ● Prepare Test Strips just before the measurement. Take out only the necessary number of Test Strips to use and close the cap. If Test Strips are left out for a long time, they may absorb humidity or collect dust, causing incorrect measurement results. ● Do NOT touch the reagent pad of the Test Strip. Do NOT touch the reagent pad of the Test Strip, otherwise correct measurement results may not be obtained. ● Set Test Strip type. Set the Test Strip type before measurement. If different Test Strips are used, correct measurement results may not be obtained. ● Keep the desiccant. Keep the desiccant contained in the Test Strip container until all Test Strips are used. 13 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL Start Up DOC. No. OM-28373 REV.5 06/05 Measurement Do NOT touch the optical system. Doing so may result in injury. 1. Preparation. ① When using the Printer, make sure that the Printer is connected to the Analyzer correctly and paper is loaded. If there is a red strip on the both sides of the paper, replace the roll. 2. Turn on the power. ① Connect the exclusive AC adapter with the power input terminal on the rear of the device (while using the AC adapter, battery is not consumed). When only the Analyzer is operated with batteries, insert batteries into the battery box at the bottom of the Analyzer. ② Press [START-ENT] on the operator panel to turn on the power. After initialization, the Ready Screen appears. There are two screens for the measurement-standby stage.(Ready Screen). In either case, press [START] to start measurement. Ready Screen 1 Ready Screen 2 The latest measurement result is displayed on the LCD. Parameters for the next measurement are displayed. (Measurement No., ID, Test Strips, Measurement Item for Test Strip) ③ Make sure that the Strip Holder is set up correctly. e AUTION MICRO 14 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Setting Up Parameters Measurement 1. Setting up the measurement number. ① Press [No.] from the Ready Screen. Measurement No. setting mode appears and“No.”and the cursor blinks. ② Enter any numbers using the numeric keys.(Max. 4 digits) ③ Press [ENT] to confirm the entry. Press [STOP] to cancel, and the Ready Screen is restored. Reference Measurement No. can be set arbitrarily. Once the Measurement No. is set, the number increases with every measurement. 2. Setting up of Patient ID. ① Enter [ID] from the Ready Screen. The patient ID setting mode appears and“ID”and the cursor blinks. ② Enter any numbers using the numeric keys. (Max. 13 digits including hyphens) ③ Press [ENT] to confirm the entry. The Ready Screen is restored. Reference 1: [STOP] functions as a hyphen key. To cancel the entry, press [ENT] once before re-entry. 2: When the patient ID is entered, the Ready or Measurement screen displays Measurement No. and Patient ID alternately. 3: Patient ID is included in the printing results and external transmission. (When not entered, -----------is displayed.) 3. Setting of Test Strip Type. ① Press [STRIP] from the Ready Screen, Test Strip type selection mode appears and“STRIP”blinks, and the Test Strip type and Item are displayed. ② To change the Test Strip type and Item, press [STRIP]. (10EA→9Ub(9UB)→C(CHECK)→10EA) ③ Press [ENT] to confirm the entry. Press [STOP] to cancel, and the Ready Screen is restored. 15 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.5 06/05 Normal Measurement Measurement Wear protective gloves to prevent exposure to pathogenic microbes. 1. Prepare sample. ① Prepare sample in a sample cup. Important Make sure that sample is enough to cover the whole reagent pads. Reagent Pads ② Stir sample well. Important Do NOT use a centrifuge for mixing. ③ Prepare tissue paper to wipe off excess urine. ① Take out only the necessary number of strips from the Test Strip container. ② Close the cap. Important C lo tl y 2. Prepare the Test Strip. s e th e lid ti g h Read the attached manuals for the Test Strip. e AUTION MICRO 16 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Normal Measurement Measurement 3. Press [START] to start Normal Measurement. Test Strip Icon blinks and the timer starts to count down the timing of dipping of the Test Strip from [3 sec]. (A timing buzzer also sounds in accordance with the count down.) Reference Important To stop the measurement, keep pressing [STOP] for 2-3 seconds during measurement. Do NOT move the Analyzer during measurement. If impact or shock is given to the Analyzer, measurement cannot be done correctly. The Test Strip may become jammed in the Analyzer. 4. Dip a Test Strip in the sample. Following the indicator timing (--sec), a timing buzzer sounds for 2 seconds. Keep dipping the Test Strip while the buzzer is sounding. Important Dip the Test Strip properly for 2 seconds following the sound of the timing buzzer. Shorter dipping time may result in insufficient coloring and longer dipping time may cause discharging of the reagent. 5. Remove the excess sample. When the timing buzzer stops, pull out the Test Strip and remove the excess sample with tissue paper. 17 AUTION MICRO Do NOT dip the black marker AUTION MICRO PU-4210 OPERATING MANUAL Normal Measurement DOC. No. OM-28373 REV.0 04/01 Measurement 6. Set the Test Strip. While the Test Strip Icon is blinking, place the Test Strip onto the Strip Holder. Reference Important A few seconds before the Strip Holder moves inside of the Analyzer, the Test Strip Icon stops blinking. When the Strip Holder is set inside the Analyzer, the Test Strip Icon disappears. If the Test Strip is not correctly set on the Strip Holder, correct measurement results cannot be obtained. Make sure that the tip of Test Strip reaches to the left end of the holder. 7. Measurement. The Strip Holder is pulled into the Analyzer and the measurement starts. 8. Finish Measurement. When measurement is completed,the measurement result is displayed and the Strip Holder comes out from the Analyzer. Discard the used Test Strip, and when finishing the whole measurement process, remove the Strip Holder from the Analyzer and clean it. 9. Turn off the power. Keep pressing [START] for 2-3 seconds to turn off the power (the Strip Holder is pulled into the Analyzer automatically). Reference When no key entry is made for more than 3 minutes, the power automatically turns off. AUTION MICRO 18 DOC. No. OM-28373 REV.5 06/05 AUTION MICRO PU-4210 OPERATING MANUAL Check Measurement Measurement For installation, read the following precautions carefully and always follow safety measures. Wear protective gloves to prevent exposure to pathogenic microbes. 1. Clean the Strip Holder. Wash the Strip Holder and dry it completely with the soft cloth. See“Maintenance”. Note Make sure the holder is clean, otherwise dirt may adhere to the Check Strip and damage it. 2. Set the Test Strip Type. Set the Test Strip Type to C (Check). See“Setting Up Parameters”. 3. Prepare a Check Strip. Remove 1 Check Strip from the Check Strip container. Important Do NOT touch the graycolored part of Check Strip. Check Strip(Gray) Semiquantitative Value Label e 19 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Check Measurement Measurement 4. Press [START] to start Check Measurement. While the Test Strip Icon is blinking, place the Check Strip onto the Strip Holder. Reference A few seconds before the Strip Holder moves inside of the Analyzer, the Test Strip Icon stops blinking. When the Strip Holder is set inside the Analyzer, the Test Strip Icon disappears. 5. Confirm the results. Compare the Check Measurement results with the ranges of semiquantitative values attached to the Check Strips container. ●When the Check Measurement results are within the range: The Analyzer is performing correctly. End Check Measurement. ●When the Check Measurement results are out of the range: Repeat the Check Measurement with the other Check Strip. 6. Repeat the Check Measurement with the other Check Strip. ●If the second Check Measurement results are within the range: The Check Strip used for the first measurement was defective. Do NOT use it again. ●If the second Check Measurement results are still out of the range: Contact your distributor. AUTION MICRO 20 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Auxiliary Function 1. Calendar Display and Setting. ① Press [DATE] from the Ready Screen, the current date is displayed. (The Ready Screen is restored in 2-3 seconds automatically.) ② Press [DATE] again while the date is displayed, the Date Setting Screen appears and“DATE” and cursor blink. ③ Enter the current date. ④ Press [ENT] to confirm the entry. Press [STOP] to cancel, and the Ready Screen is restored. 2. Time Display and Setting. ① Press [TIME] from the Ready Screen, current time is displayed. (The Ready Screen is restored in 2-3 seconds automatically). ② Press [TIME] again while the time is displayed, the Time Setting Screen appears and [TIME] and cursor blink. ③ Enter the current time. ④ Press [ENT] to confirm the entry. Press [STOP] to cancel, and the Ready Screen is restored. 21 AUTION MICRO Measurement AUTION MICRO PU-4210 OPERATING MANUAL Auxiliary Function DOC. No. OM-28373 REV.0 04/01 Measurement 3. Redisplay of Measurement Results. ① Press [MEMORY▲] or [MEMORY▼] from the Ready screen, the latest data is redisplayed ([MEMORY] is displayed at the top left of the screen). ② Press [MEMORY▼] again, one previous data is displayed. Repeat this procedure, if necessary. ③ Press [MEMORY▲], the next data is displayed. ④ Press [STOP], the Ready Screen is restored. Reference If No., ID, DATE and TIME are pressed during Redisplay of data, Measurement No., Patient ID, Measurement Date and Measurement Time on the Redisplayed data are displayed. (Measurement No. is displayed as default. This setting is reflected in all data during a series of redisplay operation.) AUTION MICRO 22 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Auxiliary Function 4. Delete Data. A: Delete Single Data. ① Press [DELETE] on the Redisplay screen of measurement results,“DELETE”blinks. (The measurement results are also displayed.) ② Press [ENT] to delete the displayed measurement data and the next data is displayed. To cancel it, press [STOP] and the Redisplay screen is restored. B: Delete All Data. ① Keep pressing [DELETE] on the Redisplay screen of the measurement results for 2-3 seconds, “DELETE”blinks and“ALL”is displayed. (Other displayed items disappear.) ② Press [ENT] to delete all measurement data in the memory. To cancel it, press [STOP] and the Redisplay screen is restored. 5. Retransmit. A: Retransmit Single Data. ① Press [SEND] on the Redisplay screen of the measurement results, the Transmission Icon blinks. (The measurement Results are also displayed.) ② Press [ENT] to transmit the displayed measurement data. To cancel it, press [STOP] and the Redisplay screen is restored. 23 AUTION MICRO Measurement AUTION MICRO PU-4210 OPERATING MANUAL Auxiliary Function DOC. No. OM-28373 REV.0 04/01 Measurement B: Retransmit All Data. ① Keep pressing [SEND] on the Redisplay screen of the Measurement Results for 2-3 seconds, the Transmission Icon blinks and“ALL”is displayed. (Other displayed items disappear.) ② Press [ENT] to transmit all measurement data in the memory from the latest data. To cancel it, press [STOP] and the Redisplay screen is restored. Reference To stop transmission, press [STOP] during transmission. 6. Reprint. (when the Printer is connected.) A: Reprint Single Data. ① Press [PRINT] on the Redisplay screen of the measurement results, the Printer Icon blinks. (The measurement results are also displayed.) ② Press [ENT] to print the displayed measurement data. To cancel it, press [STOP] and the Redisplay screen is restored. B: Reprint All Data. ① Keep pressing [PRINT] on the Redisplay screen of the measurement results for 2-3 seconds, the Printer Icon blinks and [All] is displayed. (Other displayed items disappear.) AUTION MICRO 24 DOC. No. OM-28373 REV.01 01/01 AUTION MICRO PU-4210 OPERATING MANUAL Auxiliary Function Measurement ② Press [ENT] to print all measurement data in memory from the latest data. To cancel it, press [STOP] and the Redisplay screen is restored. Reference To stop printing, press [STOP] during printing. To print the latest data,press [PRINT] on the Ready Screen. 7. Battery Icon. A battery icon at the lower right of the analyzer display tells you the timing of battery exchange. Follow the instructions below, and replace the battery to a new one if necessary. The supplied AC adapter can be used as well. ① The battery is full with power. ① ②③ Although measurement can be continued with this battery, the power is getting ② short. Prepare a new battery. Note ④ This icon sometimes changes to the next icon (blinking) even if enough power remains in. The battery runs out. ③ ④ To continue measurement, replace the battery to a new one. 25 AUTION MICRO (Blinking) AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Special Parameters Measurement The following special parameters are available to set with the PU-4210. (The parameters are stored until the settings are changed.) ●Orientation of the Test Strip set. Setting of Test Strip from the right side or from the left side of the Analyzer (default is set to the right side). Note To change the Test Strip orientation, remove the Strip Holder from the Analyzer beforehand. ●Date Order. Choose Date order among Y-M-D, M-D-Y, and D-M-Y. (The default setting is Y-M-D). Setting is reflected on the screen display and printing. (Fixed for external output.) ●Setting of measurement units and symbols for semi-quantitative ranks. Set the measurement units for the measurement results (SI or usual) and format of semi-quantitative ranks ( +++ or +n ) ( default is set to usual, +++). Setting is reflected on the printing and external output. (Fixed for the screen display.) 1. Operation. ① Turn on the power while pressing [STOP]. (Keep pressing [STOP] during initialization.) ② After initialization, the entry screen for 3 digits numbers is displayed and the parameter setting mode appears. ③ The numeral of each digit corresponds to the following. Input the numerals for the desired setting. In this case, if numerals other than the designated ones are input, they are not accepted. previous setting Hundreds 1:Right setting 2:Left setting Tens 1:Y-M-D 2:M-D-Y 3:D-M-Y Ones 1:mg/dl,+++ 2:mg/dl,+n 3:mmol/l,+++ 4:mmol/l,+n ④ Press [ENT] after the entry to change the settings. The Ready Screen is restored. e.g.) Change from the default (Right setting, Y-M-D, mg/dl,+++) ●When“232”is entered,(Left setting, D-M-Y, mg/dl, +n) is set. Then the Ready Screen is restored. ●When“063”is entered,(Right setting, Y-M-D, mmol/l, +++) is set. Then the Ready Screen is restored. AUTION MICRO 26 DOC. No. OM-28373 REV.0 04/01 AUTION MICRO PU-4210 OPERATING MANUAL Printer Printing 1. Attachment or Removal of Printer. When connecting the Printer to the Analyzer, insert the hook of the Printer in the hole at the bottom of the Analyzer, and then slide it firmly enough to achieve a secure fit. When removing the Printer, slide the Analyzer lock release button to the front while pressing the lock release button of the Printer. Note Before you attach or remove the Printer, make sure to turn off the power and pull out the AC adapter of the Printer. 2. Paper Jam. When paper is jammed, press [FEED] of the Printer to remove the paper. 3. Loading of Paper. After confirming the face and the back of the paper, put the thermal printer paper into the insertion position, and then the paper will be fed automatically. Note When inserting a new thermal Printer paper, cut the edge with scissors to make it even, and set it in the position. 4. Error Comments. When an error occurs, error codes and error comments are printed. (Only error codes are displayed on the screen.) ※See“Troubleshooting”. 27 AUTION MICRO FEED AUTION MICRO PU-4210 OPERATING MANUAL DOC. No. OM-28373 REV.0 04/01 Printing Item Printing Measurement No. Abnormal Mark Patient ID Date・Time・ Type of Test Strip・ Temperature in Instrument Marks for abnormal values (Normal:Blank) Measurement Results Measurement Units Ranks (Semi-quantitative symbols) Measurement Item Abnormal Mark Concentration values When the measurement results is abnormal (Rank is more than“+1”.), sample abnormal mark‘●’is displayed. Measurement No. 4 digits Patient ID ID is entered using keys. When there is no ID, [------------------]is printed. Date, Time There are 3 printing patterns of the date YMD, MDY, DMY Example 2001-07-05 09:53       07-05-2001 09:53      05-07-2001 09:53 Type of Strip The Test Strip Type is displayed. Example 9UB Temperature in Temperature in the instrument is printed in ℃ Instrument Example 29℃ Measurement Abnormal Mark / Results When an abnormal measurement result (rank is over“+1”) is recognized, ‘*’is printed before the name of item. Measurement Item / GLU, URO, PRO, KET, BLD, BIL, NIT, LEU, pH, S.G. Ranks (Semi-quantitative symbols), Concentration, Measurement Units. AUTION MICRO 28 DOC. No. OM-28373 REV.5 06/05 Maintenance AUTION MICRO PU-4210 OPERATING MANUAL Troubleshooting and Maintenance Clean the Strip Holder after finishing measurement at the end of the day. Wear protective gloves to prevent exposure to pathogenic microbes. Discard used cotton swabs and used gloves according to local regulations for biohazardous waste. 1. Slide the Strip Holder to remove. 2. Wash the Strip Holder with detergent or alcohol and then rinse it with tap water. Especially, clean the groove with special care. 3. Dry the Strip Holder completely 4. Insert the Strip Holder completely with a soft cloth. by using grooves of the backside of the Strip Holder. e 29 AUTION MICRO AUTION MICRO PU-4210 OPERATING MANUAL Troubleshooting DOC. No. OM-28373 REV.0 04/01 Troubleshooting and Maintenance When measurement and/or printing trouble occurs, the Analyzer displays error codes. Perform the appropriate remedy described in the following chart. If measurement is still impossible, contact your distributor. Error Code Error Comment Cause Remedy Optical System does not function correctly. Make sure that the Strip Holder and Test Strip are set properly and turn on the power. Lamp intensity of LED is too strong. Clean the White Plate of the Strip Holder with a soft cloth moistened with water or alcohol and turn on the power. Lamp intensity of LED is too weak. Clean the White Plate of the Strip Holder with a soft cloth moistened with water or alcohol and turn on the power. E004 No Printer Paper Load printer paper. (Press [STOP] to restore the Ready Screen.) E005 Printer does not function correctly. Make sure that the Analyzer and the printer are connected correctly. (Press [STOP] to restore the Ready Screen.) E006 The Test Strip is not inserted correctly. Insert the Test Strip and Strip Holder correctly and start measurement again. (Press [STOP] to restore the Ready Screen.) E001 Optical Movement E002 Lamp Intensity High E003 Lamp Intensity Low Strip Error Important Test Strip type is not judged. AUTION MICRO 30 Specifications Analyzer No. Items Contents  1 2 3 4 Urine AUTION Sticks 10EA, Uriflet 9UB GLU, URO, PRO, KET, BLD, BIL, NIT, LEU, pH, S.G. Test strip Dual or Single (BLD only) Wavelength Reflectance Method Triple Wavelength, Individual LED (565, 632, 755nm) Manual Dipping Approx. 45 seconds/test Automatic Calibration by CAL pad LCD 12 keys 100 tests Automatic Correction Function (10-30℃) Automatic Correction according to pH measurement value Conformed to RS-232C Temperature:10∼30℃, Humidity:20∼80%RH 125(W)×87(D)×31(H) mm Approximately 300g Size AA alkali cells (×2) (Or AC adapter) 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Sample Test Strip Measurement Item Measurement Method Measurement Wavelength Sample Supply Reaction Time Calibration Function Display Operator Panel Memory Capacity Thermal Correction Function SG Correction Function External Output Measurement Environment Condition Dimensions Weight Power Supply Printer No. Items Contents  1 2 3 4 5 36 digits of half-sized characters, Line Thermal Printer Thermal Printer Paper 58mm (Width)×φ26mm 125(W)×163(D)×38(H) mm Approximately 300g AC adapter (Approximately 20W) Printer Printer Paper Dimensions Weight Power Supply 84-00259E