AutoFaucet® Parts List
Sensor Technology
Step 2 Guide the semi-assembled faucet spout through the 3-hole 4” or 8” center set in counter or sink. Step 3 Finish securing the cover plate from underneath by placing the two metal washers (E) on to each of the threaded studs. Secure with hex nut (F) and hex nut (II). Z G H
S
U
V
Cover Plates 4"
10"
8"
C
M use when not using mixing valve
W
E
S JJ
FF
LD CO
HO T
Installation & Maintenance
F L
IM P ORTA N T: PLEASE READ ENTIRE INSTRUCTIO N B O O K L E T BEFORE YOU BEGIN INSTALLATION!
X
Y
HH
Step 7 Hand tighten the valve control module assembly to the faucet shank. NOTE: Make sure the black rubber washer is in the white plastic nut before connecting the valve control module to the faucet shank
GG
II
P
Looks Clean - Is Clean.™
Step 7
Step 4
Step 8
Step 8 Mount the earth ground clamp to the cold water supply pipe.
KK BB
Step 3
Step 6 Connect the Y-Isolation Wire (GG) to one side of the brass U-tab. Then connect the Y-tab ground adapter to the other side of the U-tab. Finish connecting the two remaining grounding wires to the Y-tab.
N
EE
D
Step 6
Step 4 Secure the spout by using the following components in sequential order: a. Sink grounding tab washer (DD) b. Black bottom plastic insulator (Z) c. Lock washer (G) d. Brass mounting nut (H) e. Sensor wire connection washer (I) [IMPORTANT: Make sure this washer’s tab is rotated 180° from the sink grounding tab (DD).] f. Brass mounting nut (H) Step 5 Connect the two 12” supply hoses (L) to the mixing valve (N). Place the rubber washer (S) into the mixing valve’s brass nut fitting (as shown) and then tighten to bottom of the valve control module (K).
K
12"
Step 2
DD
H
Optional TC Faucet Universal Tool # 490142
Step 5
Step 1 Attach both threaded studs (D) to the bottom the semi-assembled cover plate.
I
Tools Required: Basin or Crescent wrench, slotted and Phillips screwdriver
Step 1
IMPORTANT - DO NOT USE PIPE DOPE OR TEFLON TAPE FOR ANY FAUCET OR SUPPLY CONNECTIONS!
LD CO
with Surround
Installing Your New Faucet
U. Valve Power Connector (Included with Valve Control A Module) 490251 V. Main Supply Line Hose 1/2” Female x 1/2” Female NPST (optional) 401627 W. Dirt Filter (optional) 490143 X. Earth Ground Kit 490244 Y. Drain Ground Assembly 490264 Z. Bottom Plastic Insulator (Included with Isolation Kit) 490254 AA. Top Plastic Insulator 490263 B BB. M4 x 12mm Screws (x2) (Included with Spout) 490320 CC. Rubber Spacer Gasket 490381 AA DD. Sink Grounding Tab Washer (Included with Installation Kit) 490254 BB EE. White Plastic Screw Spacers (x2) (Included with Coverplates) CC FF. M4 x 25mm Screws (x2) (Included with Coverplate) GG. Y-Isolation Wire (Included with Isolation Kit) 490254 SINK or COUNTERTOP HH. Split Lock Washer (Included with Isolation Kit) 490254 II. Nut (Included with Isolation Kit) 490254 J JJ. Y-tab Ground Adapter (Included with Installation Kit) KK. Thermostatic Mixing Valve (optional)402188
HO T
Milano AUTOMATIC FAUCET
A. Faucet Spout Assembly with 1.5 GPM Aerator 490230 B. Rubber Gasket for Faucet Spout Base 490145 C. 4" Domed Cover Plate (optional) 490286 8" Domed Cover Plate (optional) 490287 10" Flat Cover Plate (optional) 490238 12" Flat Cover Plate (optional) 490217 D. Threaded Cover Plate Studs (x2) 490139 E. Washers for Cover Plate (x2) 490138 F. Hex Nuts for Cover Plate (x2) 490139 G. Lock Washer (Included with Spout) 490320 H. Brass Mounting Nut (x2) 490272 I. Sensor Wire Connection Washer (Included with Isolation Kit) 490254 J. 6" Extention Hose 1/2” Male x 1/2” Female NPST (optional) 490137 K. Valve Control Box 490251 L. 12" Supply Hoses 3/8" x 3/8" (x2 optional) 490036 M. Sensor Wire (Included with Valve Control Module) 490251 N. Mixing Valve with Filter (optional) 490179 O. Battery Compartment 490157 P. Battery Compartment Screws and Anchors (x2) (Included with Battery Compartment) Q. Double-Side Foam Tape (Included with Battery Compartment) 490157 R. "D" Cell Alkaline Batteries (x4) S. Rubber Washers (x2) 490221 T. Battery Box Connector (Included with Battery Compartment) 490157
FF 12mm
25mm
x2
Q
R
x2
Instructions continued on reverse side
Optional Aerators Available:
Optional AC Adapters:
0.5 GPM (vandal resistant) #401190 1.5 GPM (vandal resistant) #401123 1.5 GPM Laminar flow #401214 2.0 GPM (vandal resistant) #401148
Single unit AC adapter 6 - unit AC adapter box AC wire assembly
#490099 #490071 #490100
NOTE: An AC wire assembly needs to be ordered for each faucet when purchasing the 6 - unit AC adapter box.
T
O
2
3
4
AutoFaucet® Parts List
Sensor Technology
Step 2 Guide the semi-assembled faucet spout through the 3-hole 4” or 8” center set in counter or sink. Step 3 Finish securing the cover plate from underneath by placing the two metal washers (E) on to each of the threaded studs. Secure with hex nut (F) and hex nut (II). Z G H
S
U
V
Cover Plates 4"
10"
8"
C
M use when not using mixing valve
W
E
S JJ
FF
LD CO
HO T
Installation & Maintenance
F L
IM P ORTA N T: PLEASE READ ENTIRE INSTRUCTIO N B O O K L E T BEFORE YOU BEGIN INSTALLATION!
X
Y
HH
Step 7 Hand tighten the valve control module assembly to the faucet shank. NOTE: Make sure the black rubber washer is in the white plastic nut before connecting the valve control module to the faucet shank
GG
II
P
Looks Clean - Is Clean.™
Step 7
Step 4
Step 8
Step 8 Mount the earth ground clamp to the cold water supply pipe.
KK BB
Step 3
Step 6 Connect the Y-Isolation Wire (GG) to one side of the brass U-tab. Then connect the Y-tab ground adapter to the other side of the U-tab. Finish connecting the two remaining grounding wires to the Y-tab.
N
EE
D
Step 6
Step 4 Secure the spout by using the following components in sequential order: a. Sink grounding tab washer (DD) b. Black bottom plastic insulator (Z) c. Lock washer (G) d. Brass mounting nut (H) e. Sensor wire connection washer (I) [IMPORTANT: Make sure this washer’s tab is rotated 180° from the sink grounding tab (DD).] f. Brass mounting nut (H) Step 5 Connect the two 12” supply hoses (L) to the mixing valve (N). Place the rubber washer (S) into the mixing valve’s brass nut fitting (as shown) and then tighten to bottom of the valve control module (K).
K
12"
Step 2
DD
H
Optional TC Faucet Universal Tool # 490142
Step 5
Step 1 Attach both threaded studs (D) to the bottom the semi-assembled cover plate.
I
Tools Required: Basin or Crescent wrench, slotted and Phillips screwdriver
Step 1
IMPORTANT - DO NOT USE PIPE DOPE OR TEFLON TAPE FOR ANY FAUCET OR SUPPLY CONNECTIONS!
LD CO
with Surround
Installing Your New Faucet
U. Valve Power Connector (Included with Valve Control A Module) 490251 V. Main Supply Line Hose 1/2” Female x 1/2” Female NPST (optional) 401627 W. Dirt Filter (optional) 490143 X. Earth Ground Kit 490244 Y. Drain Ground Assembly 490264 Z. Bottom Plastic Insulator (Included with Isolation Kit) 490254 AA. Top Plastic Insulator 490263 B BB. M4 x 12mm Screws (x2) (Included with Spout) 490320 CC. Rubber Spacer Gasket 490381 AA DD. Sink Grounding Tab Washer (Included with Installation Kit) 490254 BB EE. White Plastic Screw Spacers (x2) (Included with Coverplates) CC FF. M4 x 25mm Screws (x2) (Included with Coverplate) GG. Y-Isolation Wire (Included with Isolation Kit) 490254 SINK or COUNTERTOP HH. Split Lock Washer (Included with Isolation Kit) 490254 II. Nut (Included with Isolation Kit) 490254 J JJ. Y-tab Ground Adapter (Included with Installation Kit) KK. Thermostatic Mixing Valve (optional)402188
HO T
Milano AUTOMATIC FAUCET
A. Faucet Spout Assembly with 1.5 GPM Aerator 490230 B. Rubber Gasket for Faucet Spout Base 490145 C. 4" Domed Cover Plate (optional) 490286 8" Domed Cover Plate (optional) 490287 10" Flat Cover Plate (optional) 490238 12" Flat Cover Plate (optional) 490217 D. Threaded Cover Plate Studs (x2) 490139 E. Washers for Cover Plate (x2) 490138 F. Hex Nuts for Cover Plate (x2) 490139 G. Lock Washer (Included with Spout) 490320 H. Brass Mounting Nut (x2) 490272 I. Sensor Wire Connection Washer (Included with Isolation Kit) 490254 J. 6" Extention Hose 1/2” Male x 1/2” Female NPST (optional) 490137 K. Valve Control Box 490251 L. 12" Supply Hoses 3/8" x 3/8" (x2 optional) 490036 M. Sensor Wire (Included with Valve Control Module) 490251 N. Mixing Valve with Filter (optional) 490179 O. Battery Compartment 490157 P. Battery Compartment Screws and Anchors (x2) (Included with Battery Compartment) Q. Double-Side Foam Tape (Included with Battery Compartment) 490157 R. "D" Cell Alkaline Batteries (x4) S. Rubber Washers (x2) 490221 T. Battery Box Connector (Included with Battery Compartment) 490157
FF 12mm
25mm
x2
Q
R
x2
Instructions continued on reverse side
Optional Aerators Available:
Optional AC Adapters:
0.5 GPM (vandal resistant) #401190 1.5 GPM (vandal resistant) #401123 1.5 GPM Laminar flow #401214 2.0 GPM (vandal resistant) #401148
Single unit AC adapter 6 - unit AC adapter box AC wire assembly
#490099 #490071 #490100
NOTE: An AC wire assembly needs to be ordered for each faucet when purchasing the 6 - unit AC adapter box.
T
O
2
3
4
Sensor Technology
R. “D” Cell Alkaline Batteries (x4) S. Rubber Washers (x2) 490221 A T. Batter Box Connector (Included with Battery Compartment 490157) U. Valve Power Connector (Included with Valve Control Module 490251) V. Main Supply Line Hose ½”Female x ½” Female NPST(optional) 401627 W. Dirt Filter (optional) 490143 X. Earth Ground Kit 490244 Y. Drain Ground Kit 490264 Z. Bottom Plastic Insulator (Included with Isolation Kit 490254) AA. Top Plastic Insulator 490333 BB. M4 x 10mm Screws (x2) (Included with Spout 490319) SINK or COUNTERTOP CC. Rubber Spacer Gasket 490336 DD. Sink Grounding Tab Washer (Included with Isolation Kit 490254) EE. White Plastic Screw Spacers (x2) (Included with Cover Plates) FF. M4 x 25mm Screws (x2) (Included with Cover Plates) J GG. Y-Isolation Wire (Included with Isolation Kit 490254) HH. Split Lock Washer (Included with Isolation Kit 490254) II. Hex Nut (Included with Isolation Kit 490254) JJ. Y-Tab Ground Adapter (Included with Isolation Kit 490254) KK. Thermostatic Mixing Valve (optional) 402188
B
Step 2 Guide the semi-assembled faucet spout through the 3-hole 4” or 8” center set in counter or sink.
AA
BB
Step 3 Finish securing the cover plate from underneath by placing the two metal washers (E) on to each of the threaded studs. Secure with hex nut (F) and hex nut (II).
CC
DD
Z G H I H U
S
4"
M
X
W
8" LD
CO
T HO
Installation & Maintenance
E
Step 3
Step 7 Hand tighten the valve control module assembly to the faucet shank. NOTE: Make sure the black rubber washer is in the white plastic nut before connecting the valve control module to the faucet shank
L
HH
FF
F
GG
BB
KK
FF 10mm
II
Step 7
Step 4
Step 8
Step 8 Mount the earth ground clamp to the cold water supply pipe.
25mm
x2
P
x2
Looks Clean - Is Clean.™
Step 4 Secure the spout by using the following components in sequential order: a. Sink grounding tab washer (DD) b. Black bottom plastic insulator (Z) c. Lock washer (G) d. Brass mounting nut (H) e. Sensor wire connection washer (I) [IMPORTANT: Make sure this washer’s tab is rotated 180° from the sink grounding tab (DD).] f. Brass mounting nut (H)
JJ EE
D
IM P ORTA N T: PLEASE READ ENTIRE INSTRUCTIO N B O O K L E T BEFORE YOU BEGIN INSTALLATION!
Step 6
Step 6 Connect the Y-tab ground adapter to one side of the U-tab. Then connect the Y-Isolation Wire (GG) to the other side of the brass U-tab. Finish connecting the two remaining grounding wires to the Y-tab.
S N
C
Step 2
Step 5 Connect the two 12” supply hoses (L) to the mixing valve (N). Place the rubber washer (S) into the mixing valve’s brass nut fitting (as shown) and then tighten to bottom of the valve control module (K).
K
Tools Required: Basin or Crescent wrench, slotted and Phillips screwdriver Optional TC Faucet Universal Tool # 490142 Y
Step 5
Step 1 Attach both threaded studs (D) to the bottom of the semi-assembled cover plate.
V
Cover Plates
Step 1
IMPORTANT - DO NOT USE PIPE DOPE OR TEFLON TAPE FOR ANY FAUCET OR SUPPLY CONNECTIONS!
LD CO
with Surround
A. Faucet Spout Assembly with 1.5GPM Aerator 490319 B. Rubber Gasket for Faucet Spout Base 490330 C. 4” Cover Plate (optional) 490324 8” Cover Plate (optional) 490325 D. Threaded Cover Plate Studs (x2) 490139 E. Washers for Cover Plate (x2) 490138 F. Hex Nuts for Cover Plate (x2) 490139 G. Lock Washer (Included with Spout 490319) H. Brass Mounting Nut (x2) 490272 I. Sensor Wire Connection Washer (Included with Isolation Kit 490254) J. 6” Extension Hose ½”Male x ½”Female NPST (optional) 490137 K. Valve Control Module 490251 L. 12” Supply Hoses 3/8” x 3/8” compression (x2) (optional) 490036 M. Sensor Wire (Included with Valve Control Module 490251) N. Mixing Valve with Filter (optional) 490179 O. Battery Compartment 490157 P. Battery Compartment Screws and Anchors (x2) (Included with Battery Compartment 490157) Q. Double-Sided Foam Tape (Included with Battery Compartment 490157)
HO T
Verona AUTOMATIC FAUCET
Installing Your New Faucet
AutoFaucet® Parts List
Optional Aerators Available:
Optional AC Adapters:
0.5 GPM (vandal resistant) #401190 1.5 GPM (vandal resistant) #401123 1.5 GPM Laminar flow #401214 2.0 GPM (vandal resistant) #401148
Single unit AC adapter 6 - unit AC adapter box AC wire assembly
Q
Instructions continued on reverse side
#490099 #490071 #490100
NOTE: An AC wire assembly needs to be ordered for each faucet when purchasing the 6 - unit AC adapter box.
R
T
O
2
3
4
V. W. X. Y. Z. AA. BB. CC. DD. EE. FF. GG. HH. II. JJ. KK.
AA
BB
Step 3 Finish securing the cover plate from underneath by placing the two metal washers (E) on to each of the threaded studs. Secure with hex nut (F) and hex nut (II).
CC
DD
Z G H I H U
S
M
X
8" N T HO
E
Step 4 Secure the spout by using the following components in sequential order: a. Sink grounding tab washer (DD) b. Black bottom plastic insulator (Z) c. Lock washer (G) d. Brass mounting nut (H) e. Sensor wire connection washer (I) [IMPORTANT: Make sure this washer’s tab is rotated 180° from the sink grounding tab (DD).] f. Brass mounting nut (H)
Step 3
Step 7
JJ HH
EE
D
Step 7 Hand tighten the valve control module assembly to the faucet shank. NOTE: Make sure the black rubber washer is in the white plastic nut before connecting the valve control module to the faucet shank
L
FF
IM P ORTA N T: PLEASE READ ENTIRE INSTRUCTIO N B O O K L E T BEFORE YOU BEGIN INSTALLATION!
Step 6
Step 6 Connect the Y-Isolation Wire (GG) to one side of the brass U-tab. Then connect the Y-tab ground adapter to the other side of the U-tab. Finish connecting the two remaining grounding wires to the Y-tab.
S
C
Step 2
Step 5 Connect the two 12” supply hoses (L) to the mixing valve (N). Place the rubber washer (S) into the mixing valve’s brass nut fitting (as shown) and then tighten to bottom of the valve control module (K).
W
4"
Installation & Maintenance
Step 2 Guide the semi-assembled faucet spout through the 3-hole 4” or 8” center set in counter or sink.
B
K
Cover Plates
Step 5
Step 1 Attach both threaded studs (D) to the bottom the semi-assembled cover plate.
V
Tools Required: Basin or Crescent wrench, slotted and Phillips screwdriver Optional TC Faucet Universal Tool # 490142 Y
Step 1
IMPORTANT - DO NOT USE PIPE DOPE OR TEFLON TAPE FOR ANY FAUCET OR SUPPLY CONNECTIONS!
LD CO
U.
“D” Cell Alkaline Batteries (x4) Rubber Washers (x2) 490221 A Batter Box Connector (Included with Battery Compartment 490157) Valve Power Connector (Included with Valve Control Module 490251) Main Supply Line Hose ½”Female x ½”Female NPST(optional) 401627 Dirt Filter (optional) 490143 Earth Ground Kit 490244 Drain Ground Kit 490264 Bottom Plastic Insulator (Included with Isolation Kit 490254) Top Plastic Insulator 490334 M4 x 10mm Screws (x2) (Included with Spout 490320) SINK or COUNTERTOP Rubber Spacer Gasket 490337 Sink Grounding Tab Washer (Included with Isolation Kit 490254) White Plastic Screw Spacers (x2) (Included with Cover Plates) M4 x 25mm Screws (x2) (Included with Cover Plates) J Y-Isolation Wire (Included with Isolation Kit 490254) Split Lock Washer (Included with Isolation Kit 490254) Nut (Included with Isolation Kit 490254) Y-Tab Ground Adapter (Included with Isolation Kit 490254) Thermostatic Mixing Valve (optional) 402188
HO T
Sensor Technology
R. S. T.
LD
with Surround
A. Faucet Spout Assembly with 1.5GPM Aerator 490320 B. Rubber Gasket for Faucet Spout Base 490331 C. 4” Cover Plate (optional) 490326 8” Cover Plate (optional) 490327 D. Threaded Cover Plate Studs (x2) 490139 E. Washers for Cover Plate (x2) 490138 F. Hex Nuts for Cover Plate (x2) 490139 G. Lock Washer (Included with Spout 490320) H. Brass Mounting Nut (x2) 490272 I. Sensor Wire Connection Washer (Included with Isolation Kit 490254) J. 6” Extension Hose ½”Male x ½”Female NPS T (optional) 490137 K. Valve Control Module 490251 L. 12” Supply Hoses 3/8” x 3/8” compression (x2) (optional) 490036 M. Sensor Wire (Included with Valve Control Module 490251) N. Mixing Valve with Filter (optional) 490179 O. Battery Compartment 490157 P. Battery Compartment Screws and Anchors (x2) (Included with Battery Compartment 490157) Q. Double-Sided Foam Tape (Included with Battery Compartment 490157)
CO
Capri AUTOMATIC FAUCET
Installing Your New Faucet
AutoFaucet® Parts List
GG
F
II
BB
KK
FF 10mm
Step 4
Step 8
Step 8 Mount the earth ground clamp to the cold water supply pipe.
25mm
x2
P
x2
Looks Clean - Is Clean.™
Optional Aerators Available:
Optional AC Adapters:
0.5 GPM (vandal resistant) #401190 1.5 GPM (vandal resistant) #401123 1.5 GPM Laminar flow #401214 2.0 GPM (vandal resistant) #401148
Single unit AC adapter 6 - unit AC adapter box AC wire assembly
Q
Instructions continued on reverse side
#490099 #490071 #490100
NOTE: An AC wire assembly needs to be ordered for each faucet when purchasing the 6 - unit AC adapter box.
R
T
O
2
3
4
Figure 1
AutoFaucet®
Step 9
Step 9 Connect the longer green earth ground wire to the clamp tab.
Step 13
A
Note: Above counter parts come pre-assembled.
IMPORTANT: All Wires MUST BE connected as shown!
Step 12 Connect the ring terminal on the green Y-Isolation wire (GG) to the stud with the hex nut (II). Continue fastening with lock washer (HH) and hex nut (J). [NOTE: For single-hole mounted faucets remove the ring terminal wire with wire cutters.]
Step 10
Step 14
5.
G
I
3.
There is a temperature adjustment on the optional thermostatic mixing valve (KK). Use an allen wrench to turn adjustment screw to add hot or cold water.
Improper or poor connection to power supply
Check that the connection from the battery box (T) is fully inserted into the female connector on the valve control module (K) and assure the connector round thumbnut is fully fastened.
(No flashing red LED located on valve control module)
RESET BUTTON
Low batteries
(Red LED is flashing)
Water source valves turned off
Open water source valves and check that there is water flow.
Sensor shorted to ground or unit unable to calibrate
If red indicator is flashing once or multiple times every 4 seconds, there is a problem with the installation and the sensor is shorted. To verify the valve control module is working correctly, carefully disconnect the black sensor wire (M) from the connection washer (I). With the wire disconnected, touch the connector at the end of the black wire with your fingers. The sensor should activate and water should come on. Let go of the connector (M) and the water should shut off. If the unit works as described above, it malfunctions when you reconnect the black sensor wire to the spout assembly, then there is an error in the spout and cover plate installation. If the faucet does not activate as described when touching the sensor connector, then you have a grounding issue or there is a broken sensor wire (see troubleshooting below).
Improper ground connection
If you can touch any of the steel braided supply hoses, the brass fitting on the valve control module, or the mixing valve and it activates the unit, there is improper earth grounding (X). Verify that the ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a proper ground connection. Press reset button on valve control module after making any adjustments.
Broken or corrupt sensor wire or defective valve control module electronics.
If the connector has broken off of the black sensor wire or the valve control module appears to be defective please contact Technical Concepts. Do not attempt to repair the valve control module (K) or sensor wire (M).
Poor sensor washer and wire connection
Verify the brass nuts (H) that fasten the connection washer (I) are fully tightened. Reconnect the sensor wire (M) to the washer. Press reset button on valve control module after making any adjustments
Insufficient ground connection
Verify that the earth ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a robust ground connection. Press reset button on valve control module.
SST faucet components are in contact with metal parts of the sink or plumbing.
Be sure that all of the SST faucet components (cover plate, white plastic screw spacers, brass shank, metal washer, braided hoses) or any components for the sink (metal sink lip / mounting hardware) or countertop (i.e. metal support brackets / structural parts) are not in contact and are spaced from each other. Press reset button on valve control module after making any adjustments
Step 12
5
Intermittent cycling and /or faucet actuation is overly sensitive
Isolation parts are not installed or not installed correctly.
If you can touch the sink and the faucet activates, the unit installation is improper. Check that isolation components (AA, EE, & Z) are used and installed correctly. If the sink is of a metal composition, verify the sink ground connection (DD & GG) is in place and installed properly.
6
Faucet doesn’t shut off after you pull your hands away
Drain grounding not connected or assembled.
Check that the drain ground (Y) is assembled to the threaded portion of the metal drain ring (not on the pipe) and is connected to the tab on the valve control module (K). Press reset button on valve control module after making any adjustments.
Water stays on
There is sensor short to ground or unit is not calibrating.
Press reset button located on the face of the valve control module (K). The valve should close and the water will stop running. Let unit recalibrate for 20 seconds and verify faucet activation. If water continues to run, then there is an error in the installation and grounding scheme (see troubleshooting above).
Dial set to the "open" position or not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet by placing your hand near the spout. Water should stop running and unit will return to the normal idle operation mode when you remove your hand from the spout.
Debris or particulate matter is trapped in valve
Turn off water source valves. Remove aerator from end of the spout (A) and examine for dirt and particulates. Inspect and clean input dirt filter (W). Reinsert filter and turn water source back on. Actuate faucet several times without the aerator installed to flush any debris from the valve mechanism until dripping has ceased. Reinstall aerator.
Dial not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet several times by placing your hand near the spout. Water should stop running or dripping and unit will return to the normal idle operation mode once you remove your hand from the spout.
7
S
L CO
D
Drain Ground Wire
HO
IMPORTANT: Must have tight connection around drain!
Step 16
O
W
T
use when not using mixing valve
Y
MANUAL OVERRIDE DIAL
K
(gre en)
attach to drain
AUTO
(green)
Step 15
(gre en)
L
Leaky faucet
IMPORTANT: Must have tight connection to metal supply line!
8
9 N
10
X
11
C
H 6
Increase or decrease water flow Size of aerator or water supply flow Water temperature too hot or cold
No mixing valve installed or mixing valve needs adjustment
Flushing faucet for regulatory protocol
Required hygiene or sanitary procedure
First check that the water supply line valves are fully open and the lines are not restricted. If water flow is not as desired, optional sized aerators to control water flow (0.5 & 2.0 GPM) can be purchased. Install a mixing valve (N). Adjustments can be made to the valve by resetting the temperature control knob. If more precise or anti scald water temperature control is required, the optional thermostatic control valve (KK) may need to be purchased. Turn the knob on the side of the valve control module (K) to the "open" position to flush faucet. This is a mechanical override of the automatic sensing and will set the valve to a constant open position. Once the water is flushed as required, turn the knob back fully to the "auto" position (until it hits the stop) and cease water flow by placing hand near faucet and pulling hand away.
For technical assistance, please call 1-800-551-5155
W
5
If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries (R).
Faucet not working and no water flows when activated
RED INDICATOR
OPEN
Step 11
(green)
Drain Ground Wire
Setting Water Temperature Mix
Once you have the desired water mix temperature, lock the control knob in place with a screwdriver.
Remove cover from battery box (O) check that the batteries (R) have been inserted to the correct orientation and are making connection to the contacts. Refer to the battery icons located on the base of the battery box tray.
4
Verify water supply connections are not leaking.
2.
Batteries not inserted correctly
Intermittent cycling and/or water runs on after actuation
T
U
S
Turn water supply on. The water will automatically come on when you place your hand under the faucet. The water will stay on for a maximum of 15 seconds as long as your hands are under the faucet, and moving. The water will shut off after you remove your hands from the sensing zone or water stream.
There is a temperature dial on the mixing valve (N). Use a screwdriver to loosen the screw on the dial. [To add hot water, turn the knob to the right or to the left to add cold water. ]
Faucet not working
Black Sensor Wire
M GG
Remove battery compartment cover by unscrewing the two Phillips screws. Inside the battery compartment (O) there are two large screws and anchors (P). Place the battery compartment (O) in a convenient location ensuring easy access.
1.
Use the optional flexible 6" extension hose (J). It is to be placed between the spout shank (A) and the outlet of the valve control module (K). The faucet components can then be assembled off to one side of the drain or other plumbing. Do not add any plumbing or piping components not Included in this kit to the faucet installation as it may cause the faucet to not function or sense properly.
Z
H
II
Battery Compartment Installation
4.
H HH
NOTE: · If the optional 6” extension hose (J) is used between the valve control module (K) and the faucet shank connection (to lower the unit down for accessibility), the rubber washer (S) is not required. · If this is an AC adapter installation, skip “Battery Compartment Installation” and use instructions supplied with the AC adapter.
Install four (4) "D" cell alkaline batteries (R). Replace cover on battery compartment. Connect battery box connector (T) to valve power connector (U). Once power is established, you will hear a clicking sound when you place your hand under the faucet.
F D
Step 16 Connect the water supply hoses (L) to the valve stops. Turn on the hot and cold water supply and test faucet.
3.
Drain pipe or other plumbing under the sink or countertop is in the way.
EE
CC
Solution
Install issues due to drain pipe obstructions
DD
E
Step 15 Connect the black sensor wire to the sensor washer (I).
Secure to wall using screws and anchors (P) or double-sided tape (Q).
FF
AA
Cause
3
Step 14 See battery compartment installation instructions below. Then connect the battery power connector wires together. Test the black sensor wire with your fingers. There will be a clicking sound coming from the valve control module indicating that the faucet is installed properly.
2.
2
B
C
Step 13 Connect the other end of the green Y-Isolation wire (GG) to the sink grounding washer (DD).
1.
Problem
1
Step 10 Mount the drain ground clamp to the metal drain tail stock as close to the sink as possible. Step 11 Connect the shorter green drain ground wire to the clamp tab.
Troubleshooting Guide
Web: www.technicalconcepts.com Email:
[email protected]
7
Technical Concepts LLC. 1301 Allanson Road Mundelein, Illinois 60060 U.S.A. ☎ 847-837-4100 Fax: 1-800-551-5046
108070 Rev.A 6/06
Figure 1
AutoFaucet®
Step 9
Step 9 Connect the longer green earth ground wire to the tab.
Step 13
A
Note: Above counter parts come pre-assembled.
IMPORTANT: All Wires MUST BE connected as shown!
Step 12 Connect the ring terminal of the Y-Isolation wire (GG) to the stud with the hex nut (II). Continue fastening with lock washer (HH) and hex nut (J). [NOTE: For single-hole mounted faucets remove the ring terminal wire with wire cutters.]
Step 10
Step 14
5.
G
I
3.
There is a temperature adjustment on the optional thermostatic mixing valve (KK). Use an allen wrench to turn adjustment screw to add hot or cold water.
Improper or poor connection to power supply
Check that the connection from the battery box (T) is fully inserted into the female connector on the valve control module (K) and assure the connector round thumbnut is fully fastened.
(No flashing red LED located on valve control module)
RESET BUTTON
Low batteries
(Red LED is flashing)
Water source valves turned off
Open water source valves and check that there is water flow.
Sensor shorted to ground or unit unable to calibrate
If red indicator is flashing once or multiple times every 4 seconds, there is a problem with the installation and the sensor is shorted. To verify the valve control module is working correctly, carefully disconnect the black sensor wire (M) from the connection washer (I). With the wire disconnected, touch the connector at the end of the black wire with your fingers. The sensor should activate and water should come on. Let go of the connector (M) and the water should shut off. If the unit works as described above, it malfunctions when you reconnect the black sensor wire to the spout assembly, then there is an error in the spout and cover plate installation. If the faucet does not activate as described when touching the sensor connector, then you have a grounding issue or there is a broken sensor wire (see troubleshooting below).
Improper ground connection
If you can touch any of the steel braided supply hoses, the brass fitting on the valve control module, or the mixing valve and it activates the unit, there is improper earth grounding (X). Verify that the ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a proper ground connection. Press reset button on valve control module after making any adjustments.
Broken or corrupt sensor wire or defective valve control module electronics.
If the connector has broken off of the black sensor wire or the valve control module appears to be defective please contact Technical Concepts. Do not attempt to repair the valve control module (K) or sensor wire (M).
Poor sensor washer and wire connection
Verify the brass nuts (H) that fasten the connection washer (I) are fully tightened. Reconnect the sensor wire (M) to the washer. Press reset button on valve control module after making any adjustments
Insufficient ground connection
Verify that the earth ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a robust ground connection. Press reset button on valve control module.
SST faucet components are in contact with metal parts of the sink or plumbing.
Be sure that all of the SST faucet components (cover plate, white plastic screw spacers, brass shank, metal washer, braided hoses) or any components for the sink (metal sink lip / mounting hardware) or countertop (i.e. metal support brackets / structural parts) are not in contact and are spaced from each other. Press reset button on valve control module after making any adjustments
Step 12
5
Intermittent cycling and /or faucet actuation is overly sensitive
Isolation parts are not installed or not installed correctly.
If you can touch the sink and the faucet activates, the unit installation is improper. Check that isolation components (AA, EE, & Z) are used and installed correctly. If the sink is of a metal composition, verify the sink ground connection (DD & GG) is in place and installed properly.
6
Faucet doesn’t shut off after you pull your hands away
Drain grounding not connected or assembled.
Check that the drain ground (Y) is assembled to the threaded portion of the metal drain ring (not on the pipe) and is connected to the tab on the valve control module (K). Press reset button on valve control module after making any adjustments.
Water stays on
There is sensor short to ground or unit is not calibrating.
Press reset button located on the face of the valve control module (K). The valve should close and the water will stop running. Let unit recalibrate for 20 seconds and verify faucet activation. If water continues to run, then there is an error in the installation and grounding scheme (see troubleshooting above).
Dial set to the "open" position or not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet by placing your hand near the spout. Water should stop running and unit will return to the normal idle operation mode when you remove your hand from the spout.
Debris or particulate matter is trapped in valve
Turn off water source valves. Remove aerator from end of the spout (A) and examine for dirt and particulates. Inspect and clean input dirt filter (W). Reinsert filter and turn water source back on. Actuate faucet several times without the aerator installed to flush any debris from the valve mechanism until dripping has ceased. Reinstall aerator.
Dial not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet several times by placing your hand near the spout. Water should stop running or dripping and unit will return to the normal idle operation mode once you remove your hand from the spout.
7
S
L CO
D
Drain Ground Wire
HO
IMPORTANT: Must have tight connection around drain!
Step 16
O
W
T
use when not using mixing valve
Y
MANUAL OVERRIDE DIAL
K
(gre en)
attach to drain
AUTO
(green)
Step 15
(gre en)
L
Leaky faucet
IMPORTANT: Must have tight connection to metal supply line!
8
9 N
10
X
11
C
H 6
Increase or decrease water flow Size of aerator or water supply flow Water temperature too hot or cold
No mixing valve installed or mixing valve needs adjustment
Flushing faucet for regulatory protocol
Required hygiene or sanitary procedure
First check that the water supply line valves are fully open and the lines are not restricted. If water flow is not as desired, optional sized aerators to control water flow (0.5 & 2.0 GPM) can be purchased. Install a mixing valve (N). Adjustments can be made to the valve by resetting the temperature control knob. If more precise or anti scald water temperature control is required, the optional thermostatic control valve (KK) may need to be purchased. Turn the knob on the side of the valve control module (K) to the "open" position to flush faucet. This is a mechanical override of the automatic sensing and will set the valve to a constant open position. Once the water is flushed as required, turn the knob back fully to the "auto" position (until it hits the stop) and cease water flow by placing hand near faucet and pulling hand away.
For technical assistance, please call 1-800-551-5155
W
5
If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries (R).
Faucet not working and no water flows when activated
RED INDICATOR
OPEN
Step 11
(green)
Drain Ground Wire
Setting Water Temperature Mix
Once you have the desired water mix temperature, lock the control knob in place with a screwdriver.
Remove cover from battery box (O) check that the batteries (R) have been inserted to the correct orientation and are making connection to the contacts. Refer to the battery icons located on the base of the battery box tray.
4
Verify water supply connections are not leaking.
2.
Batteries not inserted correctly
Intermittent cycling and/or water runs on after actuation
T
U
S
Turn water supply on. The water will automatically come on when you place your hand under the faucet. The water will stay on for a maximum of 15 seconds as long as your hands are under the faucet, and moving. The water will shut off after you remove your hands from the sensing zone or water stream.
There is a temperature dial on the mixing valve (N). Use a screwdriver to loosen the screw on the dial. [To add hot water, turn the knob to the right or to the left to add cold water. ]
Faucet not working
Black Sensor Wire
M GG
Remove battery compartment cover by unscrewing the two Phillips screws. Inside the battery compartment (O) there are two large screws and anchors (P). Place the battery compartment (O) in a convenient location ensuring easy access.
1.
Use the optional flexible 6" extension hose (J). It is to be placed between the spout shank (A) and the outlet of the valve control module (K). The faucet components can then be assembled off to one side of the drain or other plumbing. Do not add any plumbing or piping components not Included in this kit to the faucet installation as it may cause the faucet to not function or sense properly.
Z
H
II
Battery Compartment Installation
4.
H HH
NOTE: · If the optional 6” extension hose (J) is used between the valve control module (K) and the faucet shank connection (to lower the unit down for accessibility), the rubber washer (S) is not required. · If this is an AC adapter installation, skip “Battery Compartment Installation” and use instructions supplied with the AC adapter.
Install four (4) "D" cell alkaline batteries (R). Replace cover on battery compartment. Connect battery box connector (T) to valve power connector (U). Once power is established, you will hear a clicking sound when you place your hand under the faucet.
F D
Step 16 Connect the water supply hoses (L) to the valve stops. Turn on the hot and cold water supply and test faucet.
3.
Drain pipe or other plumbing under the sink or countertop is in the way.
EE
CC
Solution
Install issues due to drain pipe obstructions
DD
E
Step 15 Connect the black sensor wire to the sensor washer (I).
Secure to wall using screws and anchors (P) or double-sided tape (Q).
FF
AA
Cause
3
Step 14 Connect the battery power connector wires together. Test the sensor wire with your fingers. There will be a clicking sound coming from the valve control module indicating that the faucet is installed properly. See battery compartment installation instructions below.
2.
2
B
C
Step 13 Connect the other end of the green Y-Isolation wire (GG) to the sink grounding washer (DD).
1.
Problem
1
Step 10 Mount the drain ground clamp to the metal drain tail stock as close to the sink as possible. Step 11 Connect the shorter green drain ground wire to the tab.
Troubleshooting Guide
Web: www.technicalconcepts.com Email:
[email protected]
7
Technical Concepts LLC. 1301 Allanson Road Mundelein, Illinois 60060 U.S.A. ☎ 847-837-4100 Fax: 1-800-551-5046
108070 Rev.A 6/06
Figure 1
AutoFaucet® Step 9 Connect the longer green earth ground wire to the tab.
Step 9
Step 13
A
2 Note: Above counter parts come pre-assembled.
Step 11 Connect the shorter green drain ground wire to the tab.
IMPORTANT: All Wires MUST BE connected as shown!
Step 12 Connect the ring terminal of the Y-Isolation wire (GG) to the stud with the hex nut (II). Continue fastening with lock washer (HH) and hex nut (J). [NOTE: For single-hole mounted faucets remove the ring terminal wire with wire cutters.]
Step 10
Step 14 Connect the battery power connector wires together. Test the sensor wire with your fingers. There will be a clicking sound coming from the valve control module indicating that the faucet is installed properly. See battery compartment installation instructions below.
CC
EE
F D
H HH
GG
G
I
T
U
AUTO
MANUAL OVERRIDE DIAL
O
(green)
Low batteries
(Red LED is flashing)
Water source valves turned off
Open water source valves and check that there is water flow.
Sensor shorted to ground or unit unable to calibrate
If red indicator is flashing once or multiple times every 4 seconds, there is a problem with the installation and the sensor is shorted. To verify the valve control module is working correctly, carefully disconnect the black sensor wire (M) from the connection washer (I). With the wire disconnected, touch the connector at the end of the black wire with your fingers. The sensor should activate and water should come on. Let go of the connector (M) and the water should shut off. If the unit works as described above, it malfunctions when you reconnect the black sensor wire to the spout assembly, then there is an error in the spout and cover plate installation. If the faucet does not activate as described when touching the sensor connector, then you have a grounding issue or there is a broken sensor wire (see troubleshooting below).
Improper ground connection
If you can touch any of the steel braided supply hoses, the brass fitting on the valve control module, or the mixing valve and it activates the unit, there is improper earth grounding (X). Verify that the ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a proper ground connection. Press reset button on valve control module after making any adjustments.
Broken or corrupt sensor wire or defective valve control module electronics.
If the connector has broken off of the black sensor wire or the valve control module appears to be defective please contact Technical Concepts. Do not attempt to repair the valve control module (K) or sensor wire (M).
Poor sensor washer and wire connection
Verify the brass nuts (H) that fasten the connection washer (I) are fully tightened. Reconnect the sensor wire (M) to the washer. Press reset button on valve control module after making any adjustments
Insufficient ground connection
Verify that the earth ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a robust ground connection. Press reset button on valve control module.
SST faucet components are in contact with metal parts of the sink or plumbing.
Be sure that all of the SST faucet components (cover plate, white plastic screw spacers, brass shank, metal washer, braided hoses) or any components for the sink (metal sink lip / mounting hardware) or countertop (i.e. metal support brackets / structural parts) are not in contact and are spaced from each other. Press reset button on valve control module after making any adjustments
5
Intermittent cycling and /or faucet actuation is overly sensitive
Isolation parts are not installed or not installed correctly.
If you can touch the sink and the faucet activates, the unit installation is improper. Check that isolation components (AA, EE, & Z) are used and installed correctly. If the sink is of a metal composition, verify the sink ground connection (DD & GG) is in place and installed properly.
6
Faucet doesn’t shut off after you pull your hands away
Drain grounding not connected or assembled.
Check that the drain ground (Y) is assembled to the threaded portion of the metal drain ring (not on the pipe) and is connected to the tab on the valve control module (K). Press reset button on valve control module after making any adjustments.
Water stays on
There is sensor short to ground or unit is not calibrating.
Press reset button located on the face of the valve control module (K). The valve should close and the water will stop running. Let unit recalibrate for 20 seconds and verify faucet activation. If water continues to run, then there is an error in the installation and grounding scheme (see troubleshooting above).
Dial set to the "open" position or not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet by placing your hand near the spout. Water should stop running and unit will return to the normal idle operation mode when you remove your hand from the spout.
Debris or particulate matter is trapped in valve
Turn off water source valves. Remove aerator from end of the spout (A) and examine for dirt and particulates. Inspect and clean input dirt filter (W). Reinsert filter and turn water source back on. Actuate faucet several times without the aerator installed to flush any debris from the valve mechanism until dripping has ceased. Reinstall aerator.
Dial not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet several times by placing your hand near the spout. Water should stop running or dripping and unit will return to the normal idle operation mode once you remove your hand from the spout.
Drain Ground Wire
HO
Step 16
Leaky faucet
S
LD CO
IMPORTANT: Must have tight connection around drain!
(gre en)
L
8 IMPORTANT: Must have tight connection to metal supply line!
9 10
N X
11
Setting Water Temperature Mix
C
H
If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries (R).
Faucet not working and no water flows when activated
W
T
Y
attach to drain
Step 12
use when not using mixing valve
Verify water supply connections are not leaking.
There is a temperature adjustment on the optional thermostatic mixing valve (KK). Use an allen wrench to turn adjustment screw to add hot or cold water.
Check that the connection from the battery box (T) is fully inserted into the female connector on the valve control module (K) and assure the connector round thumbnut is fully fastened.
7
Turn water supply on. The water will automatically come on when you place your hand under the faucet. The water will stay on for a maximum of 15 seconds as long as your hands are under the faucet, and moving. The water will shut off after you remove your hands from the sensing zone or water stream.
3.
Improper or poor connection to power supply
(No flashing red LED located on valve control module)
4
K
(gre en)
Install four (4) "D" cell alkaline batteries (R). Replace cover on battery compartment. Connect battery box connector (T) to valve power connector (U). Once power is established, you will hear a clicking sound when you place your hand under the faucet.
Once you have the desired water mix temperature, lock the control knob in place with a screwdriver.
Remove cover from battery box (O) check that the batteries (R) have been inserted to the correct orientation and are making connection to the contacts. Refer to the battery icons located on the base of the battery box tray.
RED INDICATOR
RESET BUTTON
Secure to wall using screws and anchors (P) or double-sided tape (Q).
2.
Batteries not inserted correctly
Intermittent cycling and/or water runs on after actuation
Black Sensor Wire
OPEN
Drain Ground Wire
(green)
Step 15
Remove battery compartment cover by unscrewing the two Phillips screws. Inside the battery compartment (O) there are two large screws and anchors (P). Place the battery compartment (O) in a convenient location ensuring easy access.
There is a temperature dial on the mixing valve (N). Use a screwdriver to loosen the screw on the dial. [To add hot water, turn the knob to the right or to the left to add cold water. ]
Faucet not working
Z
S
Battery Compartment Installation
1.
Use the optional flexible 6" extension hose (J). It is to be placed between the spout shank (A) and the outlet of the valve control module (K). The faucet components can then be assembled off to one side of the drain or other plumbing. Do not add any plumbing or piping components not Included in this kit to the faucet installation as it may cause the faucet to not function or sense properly.
3
M
Step 11
Drain pipe or other plumbing under the sink or countertop is in the way.
H
II
NOTE: · If the optional 6” extension hose (J) is used between the valve control module (K) and the faucet shank connection (to lower the unit down for accessibility), the rubber washer (S) is not required. · If this is an AC adapter installation, skip “Battery Compartment Installation” and use instructions supplied with the AC adapter.
5.
FF
Solution
Install issues due to drain pipe obstructions
DD
E
Step 16 Connect the water supply hoses (L) to the valve stops. Turn on the hot and cold water supply and test faucet.
4.
AA
Cause
Step 14
Step 15 Connect the black sensor wire to the sensor washer (I).
3.
B
C
Step 13 Connect the other end of the green Y-Isolation wire (GG) to the sink grounding washer (DD).
2.
Problem
1
Step 10 Mount the drain ground clamp to the metal drain tail stock as close to the sink as possible.
1.
Troubleshooting Guide
Increase or decrease water flow Size of aerator or water supply flow Water temperature too hot or cold
No mixing valve installed or mixing valve needs adjustment
Flushing faucet for regulatory protocol
Required hygiene or sanitary procedure
First check that the water supply line valves are fully open and the lines are not restricted. If water flow is not as desired, optional sized aerators to control water flow (0.5 & 2.0 GPM) can be purchased. Install a mixing valve (N). Adjustments can be made to the valve by resetting the temperature control knob. If more precise or anti scald water temperature control is required, the optional thermostatic control valve (KK) may need to be purchased. Turn the knob on the side of the valve control module (K) to the "open" position to flush faucet. This is a mechanical override of the automatic sensing and will set the valve to a constant open position. Once the water is flushed as required, turn the knob back fully to the "auto" position (until it hits the stop) and cease water flow by placing hand near faucet and pulling hand away.
For technical assistance, please call 1-800-551-5155 Web: www.technicalconcepts.com Email:
[email protected]
W
5
6
7
Technical Concepts LLC. 1301 Allanson Road Mundelein, Illinois 60060 U.S.A. ☎ 847-837-4100 Fax: 1-800-551-5046
107199 Rev. A 4/06
Figure 1
AutoFaucet® Step 9 Connect the longer green earth ground wire to the tab.
Step 9
Step 13
A
2 Note: Above counter parts come pre-assembled.
Step 11 Connect the shorter green drain ground wire to the tab.
IMPORTANT: All Wires MUST BE connected as shown!
Step 12 Connect the ring terminal of the Y-Isolation wire (GG) to the stud with the hex nut (II). Continue fastening with lock washer (HH) and hex nut (J). [NOTE: For single-hole mounted faucets remove the ring terminal wire with wire cutters.]
Step 10
Step 14 Connect the battery power connector wires together. Test the sensor wire with your fingers. There will be a clicking sound coming from the valve control module indicating that the faucet is installed properly. See battery compartment installation instructions below.
CC
EE
F D
H HH
GG
G
I
T
U
AUTO
MANUAL OVERRIDE DIAL
O
(green)
Low batteries
(Red LED is flashing)
Water source valves turned off
Open water source valves and check that there is water flow.
Sensor shorted to ground or unit unable to calibrate
If red indicator is flashing once or multiple times every 4 seconds, there is a problem with the installation and the sensor is shorted. To verify the valve control module is working correctly, carefully disconnect the black sensor wire (M) from the connection washer (I). With the wire disconnected, touch the connector at the end of the black wire with your fingers. The sensor should activate and water should come on. Let go of the connector (M) and the water should shut off. If the unit works as described above, it malfunctions when you reconnect the black sensor wire to the spout assembly, then there is an error in the spout and cover plate installation. If the faucet does not activate as described when touching the sensor connector, then you have a grounding issue or there is a broken sensor wire (see troubleshooting below).
Improper ground connection
If you can touch any of the steel braided supply hoses, the brass fitting on the valve control module, or the mixing valve and it activates the unit, there is improper earth grounding (X). Verify that the ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a proper ground connection. Press reset button on valve control module after making any adjustments.
Broken or corrupt sensor wire or defective valve control module electronics.
If the connector has broken off of the black sensor wire or the valve control module appears to be defective please contact Technical Concepts. Do not attempt to repair the valve control module (K) or sensor wire (M).
Poor sensor washer and wire connection
Verify the brass nuts (H) that fasten the connection washer (I) are fully tightened. Reconnect the sensor wire (M) to the washer. Press reset button on valve control module after making any adjustments
Insufficient ground connection
Verify that the earth ground clamp (X) has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a robust ground connection. Press reset button on valve control module.
SST faucet components are in contact with metal parts of the sink or plumbing.
Be sure that all of the SST faucet components (cover plate, white plastic screw spacers, brass shank, metal washer, braided hoses) or any components for the sink (metal sink lip / mounting hardware) or countertop (i.e. metal support brackets / structural parts) are not in contact and are spaced from each other. Press reset button on valve control module after making any adjustments
5
Intermittent cycling and /or faucet actuation is overly sensitive
Isolation parts are not installed or not installed correctly.
If you can touch the sink and the faucet activates, the unit installation is improper. Check that isolation components (AA, EE, & Z) are used and installed correctly. If the sink is of a metal composition, verify the sink ground connection (DD & GG) is in place and installed properly.
6
Faucet doesn’t shut off after you pull your hands away
Drain grounding not connected or assembled.
Check that the drain ground (Y) is assembled to the threaded portion of the metal drain ring (not on the pipe) and is connected to the tab on the valve control module (K). Press reset button on valve control module after making any adjustments.
Water stays on
There is sensor short to ground or unit is not calibrating.
Press reset button located on the face of the valve control module (K). The valve should close and the water will stop running. Let unit recalibrate for 20 seconds and verify faucet activation. If water continues to run, then there is an error in the installation and grounding scheme (see troubleshooting above).
Dial set to the "open" position or not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet by placing your hand near the spout. Water should stop running and unit will return to the normal idle operation mode when you remove your hand from the spout.
Debris or particulate matter is trapped in valve
Turn off water source valves. Remove aerator from end of the spout (A) and examine for dirt and particulates. Inspect and clean input dirt filter (W). Reinsert filter and turn water source back on. Actuate faucet several times without the aerator installed to flush any debris from the valve mechanism until dripping has ceased. Reinstall aerator.
Dial not turned to the full "auto" position
Turn the knob on the side of the valve control module (K) fully to the "auto" position (until it hits the stop) and actuate the faucet several times by placing your hand near the spout. Water should stop running or dripping and unit will return to the normal idle operation mode once you remove your hand from the spout.
Drain Ground Wire
HO
Step 16
Leaky faucet
S
LD CO
IMPORTANT: Must have tight connection around drain!
(gre en)
L
8 IMPORTANT: Must have tight connection to metal supply line!
9 10
N X
11
Setting Water Temperature Mix
C
H
If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries (R).
Faucet not working and no water flows when activated
W
T
Y
attach to drain
Step 12
use when not using mixing valve
Verify water supply connections are not leaking.
There is a temperature adjustment on the optional thermostatic mixing valve (KK). Use an allen wrench to turn adjustment screw to add hot or cold water.
Check that the connection from the battery box (T) is fully inserted into the female connector on the valve control module (K) and assure the connector round thumbnut is fully fastened.
7
Turn water supply on. The water will automatically come on when you place your hand under the faucet. The water will stay on for a maximum of 15 seconds as long as your hands are under the faucet, and moving. The water will shut off after you remove your hands from the sensing zone or water stream.
3.
Improper or poor connection to power supply
(No flashing red LED located on valve control module)
4
K
(gre en)
Install four (4) "D" cell alkaline batteries (R). Replace cover on battery compartment. Connect battery box connector (T) to valve power connector (U). Once power is established, you will hear a clicking sound when you place your hand under the faucet.
Once you have the desired water mix temperature, lock the control knob in place with a screwdriver.
Remove cover from battery box (O) check that the batteries (R) have been inserted to the correct orientation and are making connection to the contacts. Refer to the battery icons located on the base of the battery box tray.
RED INDICATOR
RESET BUTTON
Secure to wall using screws and anchors (P) or double-sided tape (Q).
2.
Batteries not inserted correctly
Intermittent cycling and/or water runs on after actuation
Black Sensor Wire
OPEN
Drain Ground Wire
(green)
Step 15
Remove battery compartment cover by unscrewing the two Phillips screws. Inside the battery compartment (O) there are two large screws and anchors (P). Place the battery compartment (O) in a convenient location ensuring easy access.
There is a temperature dial on the mixing valve (N). Use a screwdriver to loosen the screw on the dial. [To add hot water, turn the knob to the right or to the left to add cold water. ]
Faucet not working
Z
S
Battery Compartment Installation
1.
Use the optional flexible 6" extension hose (J). It is to be placed between the spout shank (A) and the outlet of the valve control module (K). The faucet components can then be assembled off to one side of the drain or other plumbing. Do not add any plumbing or piping components not Included in this kit to the faucet installation as it may cause the faucet to not function or sense properly.
3
M
Step 11
Drain pipe or other plumbing under the sink or countertop is in the way.
H
II
NOTE: · If the optional 6” extension hose (J) is used between the valve control module (K) and the faucet shank connection (to lower the unit down for accessibility), the rubber washer (S) is not required. · If this is an AC adapter installation, skip “Battery Compartment Installation” and use instructions supplied with the AC adapter.
5.
FF
Solution
Install issues due to drain pipe obstructions
DD
E
Step 16 Connect the water supply hoses (L) to the valve stops. Turn on the hot and cold water supply and test faucet.
4.
AA
Cause
Step 14
Step 15 Connect the black sensor wire to the sensor washer (I).
3.
B
C
Step 13 Connect the other end of the green Y-Isolation wire (GG) to the sink grounding washer (DD).
2.
Problem
1
Step 10 Mount the drain ground clamp to the metal drain tail stock as close to the sink as possible.
1.
Troubleshooting Guide
Increase or decrease water flow Size of aerator or water supply flow Water temperature too hot or cold
No mixing valve installed or mixing valve needs adjustment
Flushing faucet for regulatory protocol
Required hygiene or sanitary procedure
First check that the water supply line valves are fully open and the lines are not restricted. If water flow is not as desired, optional sized aerators to control water flow (0.5 & 2.0 GPM) can be purchased. Install a mixing valve (N). Adjustments can be made to the valve by resetting the temperature control knob. If more precise or anti scald water temperature control is required, the optional thermostatic control valve (KK) may need to be purchased. Turn the knob on the side of the valve control module (K) to the "open" position to flush faucet. This is a mechanical override of the automatic sensing and will set the valve to a constant open position. Once the water is flushed as required, turn the knob back fully to the "auto" position (until it hits the stop) and cease water flow by placing hand near faucet and pulling hand away.
For technical assistance, please call 1-800-551-5155 Web: www.technicalconcepts.com Email:
[email protected]
W
5
6
7
Technical Concepts LLC. 1301 Allanson Road Mundelein, Illinois 60060 U.S.A. ☎ 847-837-4100 Fax: 1-800-551-5046
107199 Rev. A 4/06