Transcript
Automotive Plug-in PCB Twin Power Relay Type CVF…A - CVF...B - CVF...C • • • •
30A to 80A continuous current capacity Automotive - oriented design Fully standardized QC size and layout Plastic cover for rough environment protection
CVF9
Typical Application • • • • •
Head lights Fog lamp Signal horn Blower motor control Starter relay
• • • •
Ordering Key Radiator cooling fan Power window ABS system Start bypass relay
CVF 93 A D 001 012/1
Type Mounting version Rating code Parallel Component Contact Form Coil Rated Voltage
Coil Data, DC (20°C) Rated voltage VDC
Winding resistance Ω±10%
Must Operate Voltage max. (VDC)
Allowable Voltage max. (VDC)
Must Release Voltage min. (VDC)
6.0 12.0 24.0
22 90 330
3.6 7.2 14.3
10.1 20.5 39.1
0.6 1.2 2.4
Contact Data CVF...A Form Max. Switching Current Material Initial Contact Resistance Max. Switching Voltage Max. Continuous Current Minimal Load Service Life
Make Break
Mechanical Electrical
1 Form A (100/100P) 1 Form C (001 120A NO120A/NC45A 40A NO40A/NC30A AgNi0,15; AgSnOInO 100mΩ max. at 0.1A, 6VDC See Curve 1, current dependent 30A NO30A/NC30A 0.1A, 12VDC 10 7 ops. 2 x 105 ops, see Note 4
Contact Data CVF...B Form Max. Switching Current Material Initial Contact Resistance Max. Switching Voltage Max. Continuous Current Minimal Load Service Life
14-16
Make Break
1 Form A (100/100P) 120A 60A
60A Mechanical Electrical
1 Form C (001) NO120A/NC45A NO60A/NC40A
AgCd0 100mΩ max. at 0.1A, 6VDC See Curve 1, current dependent NO60A/NC40A 0.5A, 12VDC 10 7 ops. 2 x 10 5 ops, see Note 4
Specifications are subject to change without notice
Automotive Plug-In PCB Twin Power Relay Type CVF…A - CVF...B - CVF...C
Contact Data CVF...C Form Max. Switching Current Material Initial Contact Resistance Max. Switching Voltage Max. Continuous Current Minimal Load Service Life
Make Break
1 Form A (100) 240A 80A
80A Mechanical Electrical
1 Form C (001) NO240A/NC180A NO80A/NC60A AgSnOInO 100mΩ max. at 0.1A, 6VDC See Curve 2, current dependent NO80A/NC60A 0.5A, 12VDC 10 7 ops. 2 x 10 5 ops, see Note 4
Contact Characteristics Operate Time Release Time Insulation Resistance Dielectric Strength Shock Resistance Vibration Resistance
7 ms. Typical 2 ms. Typical 100 MΩ, at 500 VDC, 50%RH 500 Vrms, 1 min.
Power Consumption
20 g, 11ms. 10-40Hz: DA 1.27mm; 40-70Hz: 5 g; 70-100Hz: DA 0.5mm; 100-500Hz: 10g.
Weight
Drop Resistance
Ambient Temperature
1 M height drop on concrete 1.6W, unsuppressed, 1.81W, with resistor -40°C to 105°C operating -40°C to 155°C storage 35 g. approx.
Dimensions
1. Power Lood Limit of CVF...A - CVF...B
Specifications are subject to change without notice
2. Power Lood Limit of CVF...C
14-17
Automotive Plug-In PCB Twin Power Relay Type CVF…A - CVF...B - CVF...C
Dimensions Plug-In Type 1 Form A (100)
1 Form A (100P) 1 Form C (001)
1 Form A (100)
1 Form C (001)
CVF...A, CVF...B
CVF...C
Covers 9 - Molded Bracket
14-18
93 - Skirted Cover + Metal Bracket 94 - Skirted Cover + Bent Metal Bracket
Specifications are subject to change without notice
Automotive Plug-In PCB Twin Power Relay Type CVF…A - CVF...B - CVF...C
Dimensions PCB Type CVF...C
CVF...A, CVF...B
Mounting Holes CVF...C
CVF...A, CVF...B 1 Form A (100)
1 Form C (001)
1 Form A (100)
1 Form C (001)
Wiring Diagrams 1 Form A (100)
1 Form A (100P)
1 Form C (001)
NOTES 1. All parameters, unless otherwise specified, are measured at ambient temperature 23°C. 2. Maximum make current refers to inrush current of lamp load. 3. At ambient temperature of 85°C, maximum allowable voltage should be reduced to 72%. 4. Electrical life obtained at resistive or inductive load at 20A, 15VDC for CVF…A; 40A, 15VDC for CVF…B; 80A, 15VDC for CVF…C with suitable arc-suppression circuit attached with operating frequency of 1 ops/sec. 5. Custom-made services available with operational quantity. Please let us know your special requirements. 6. Specifications subject to change without prior notice.
Specifications are subject to change without notice
14-19