Preview only show first 10 pages with watermark. For full document please download

Av Infrastructure Drawings

   EMBED


Share

Transcript

TECHNOLOGY SYMBOL LEGEND SYM FB5 FB7 FB9 FB12 J2 J3 J4 J5 J6 J8 J9 J11 J12 J14 J15 J16 J42 J43 J60 J68 J20 J21 J25 J27 J40 J41 J49 N1 N2 N3 N30 N31 N40                                  FUNCTION ENCLOSURE DESCRIPTION FLOOR BOX W/NETWORK AND POWER FLOOR CONDUIT STUB FLOOR RECESS POKE-THRU DEVICE CONDUIT CONSOLIDATION PULL BOX (BELOW SLAB) EQUIPMENT RACK PULL BOX AV I/O PANEL AV I/O PANEL - SMALL AV I/O PANEL - MEDIUM AV I/O PANEL - LARGE PROJECTION SCREEN CONTROL SWITCH (SINGLE) PROJECTION SCREEN CONTROL SWITCH (DUAL) FLAT PANEL DISPLAY WALL BOX ASSEMBLY WALL MOUNTED CAMERA WALL MOUNTED LOUDSPEAKER WALL MOUNTED LOUDSPEAKER WALL CONTROL PANEL WALL TOUCH PANEL 8" WALL TOUCH PANEL DOCK PROJECTION SCREEN CONTROL SWITCH (TRIPLE) ROOM SCHEDULER CONDUIT CONSOLIDATION PULL BOX CEILING MIC PULL BOX PROJECTION SCREEN CONTROL BOX LOUDSPEAKER PULL BOX CEILING MOUNTED VIDEO PROJECTOR CEILING MOUNTED VIDEO PROJECTOR NETWORK PULL BOX FOR ROOM SCHEDULER NETWORK OUTLET - FLOOR NETWORK WALL OUTLET FOR AV EQUIPMENT NETWORK OUTLET - FLAT PANEL DISPLAY NETWORK PULL BOX FOR VIDEO PROJECTOR NETWORK OUTLET FOR VIDEO PROJECTOR NETWORK PULL BOX FOR ROOM SCHEDULER CEILING BOXES WALL WIREMOLD EVOLUTION 8AT POKE-THRU DEVICE - FLUSH WITH FINISHED FLOOR STUB TO 3" ABOVE FINISHED FLOOR FLUSH WITH FINISHED FLOOR ABOVE ACCESSIBLE CEILING OF FLOOR BELOW 8-5/8"W x 4-1/2"H x 2-1/2"D PULL BOX W/RAISED THREE-DEVICE COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/RAISED TWO-DEVICE COVER 8"W x 6"H x 4"D PAINTED SCREW COVER PULL BOX 10"W x 8"H x 4"D PAINTED SCREW COVER PULL BOX 2-1/8"W x 4"H x 2-1/8"D UTILITY BOX 4-11/16" SQUARE x 2-1/8"D PULL BOX MOUNTED HORIZONTALLY 7-3/8"H x 10-15/16"W x 3-9/16"D PULL BOX HORIZONTALLY 4-11/16" SQUARE x 2-1/8"D PULL BOX W/RAISED TWO-DEVICE COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/RAISED SINGLE-DEVICE COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/RAISED SINGLE-DEVICE COVER 8-5/8"W x 4-1/2"H x 2-1/2"D PULL BOX W/RAISED THREE-DEVICE COVER BB-6L BACK BOX CRESTRON TPMC-8X DOCKING STATION 8-5/8"W x 4-1/2"D x 2-1/2"D PULL BOX W/RAISED THREE-DEVICE COVER 4"W x 2-/18"H x 2-1/8"D UTILITY BOX CRESTRON BB-6L BACK BOX CRESTRON TPMC-8X-DSW BACK BOX - 18" AFF - FLUSH (UNLESS OTHERWISE INDICATED) 18" AFF - FLUSH 18" AFF - FLUSH 18" AFF - FLUSH 48" AFF - FLUSH 48" AFF - FLUSH 66" AFF - FLUSH (UNLESS OTHERWISE INDICATED) 96"AFF - FLUSH (UNLESS OTHERWISE INDICATED) 90" AFF - FLUSH 102" AFF - FLUSH 48" AFF - FLUSH 48" AFF - FLUSH 48" AFF - FLUSH 48" AFF - FLUSH 48" AFF - FLUSH 18" ABOVE ACCESSIBLE CEILING 18" ABOVE LAY-IN CEILING COORDINATE W/PROJECTION SCREEN 18" ABOVE ACCESSIBLE CEILING 4" ABOVE ACCESSIBLE CEILING 4" ABOVE ACCESSIBLE CEILING 18" ABOVE ACCESSIBLE CEILING INSTALL IN FLOOR BOX PER MANUFACTURER DIRECTIONS 18" AFF - FLUSH PART OF J11 18" ABOVE ACCESSIBLE CEILING PART OF J40 18" ABOVE ACCESSIBLE CEILING 4" SQUARE X 4"D SCREW COVER PULL BOX 7-5/8"W x 3-7/8"H x 3-1/2"D - 14" SQUARE x 5"H PLENUM BOX 4-11/16" SQUARE X 2-1/8"D PULL BOX W/FLAT COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/FLAT COVER FLOOR BOX INDICATED BY FB-NUMBER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/RAISED SINGLE-DEVICE COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/FLAT COVER 4-11/16" SQUARE x 2-1/8"D PULL BOX W/FLAT COVER COORDINATE W/ASSOCIATED FLOOR BOX - WALL OUTLET FLOOR MOUNTING STYLE 12-1/8"L x 10"W x 6"D FLOOR BOX 1-1/4" EMT HARDWALL CONDUIT 8" DIAMETER x 16-3/4"D POKE-THRU DEVICE 12" SQUARE x 6"D BOX W/ FLAT COVER (PUNCH AS REQUIRED) CEILING OUTLET NETWORK ENCLOUSRE MAKE & MODEL P POWER Jx Jy POWER CKT DUPLEX RECEPTACLE FLOOR OUTLET Jx(Nx,Px) DENOTES DEVICES WHICH FALL ON THE SAME VERTICAL PLANE DBL-DUPLEX RECEPTACLE REFERENCE DETAIL LEGEND NOTES 4/AV501 5/AV501 7/AV501 1&2/AV502 4/AV502 4&5/AV501 7/AV501 4/AV502 1/AV502 - [A]+[B] [G] [E] [E] [C] [E] [E] [E] [E] [J] [J] [E] [F]+[J] [F] [H]+[G] [E]+[H]+[I] [C]+[H] [F]+[H] [F]+[H]+[J] - FBx(Nx,Px) DENOTES A DEVICE WHICH CONTAINS NETWORK & POWER OUTLETS [A] FLOOR BOXES AND FLOOR PENETRATIONS (GENERAL) VERIFY EXACT LOCATION, COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO INSTALLATION. IF THE LOCATION OF A FLOOR BOX INDICATED ON THE DRAWINGS CONFLICTS WITH EXISTING STRUCTURE, THE CONTRACTOR IS AUTHORIZED TO MOVE THE LOCATION OF THE FLOOR BOX UP TO 6IN. IN ANY DIRECTION TO CLEAR THE OBSTRUCTION. IF THE LOCATION MUST BE MOVED MORE THAN 6IN. IN ANY DIRECTION, THE CONTRACTOR SHALL CONSULT WITH THE ARCHITECT FOR FURTHER INSTRUCTIONS. [B] FB5(N1,P1) FLOOR BOX FSR INC. FL-500P FLOOR BOX. USE THE SINGLE GANG COMPARTMENT FOR DATA. USE THE TWO GANG COMPARTMENT FOR POWER AND RESERVE THE FOUR GANG COMPARTMENT FOR AV. PROVIDE POUR PAN FOR SLAB ON GRADE APPLICATIONS. PROVIDE APPROPRIATE COVER. VERIFY COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO INSTALLATION. REFER TO ELECTRICAL DRAWINGS IN SHELL AND CORE PACKAGE FOR EXACT LOCATIONS AND SPECIFICATIONS. RA Project No.:1266.A TYPE LEGEND NOTES [C] FLAT PANEL DISPLAY BOX J11(N3,P4) FSR PWB-100 WALL BOX. INCLUDES NETWORK OUTLET N3 AND POWER RECEPTACLE P4. ASSEMBLY COMES STANDARD WITH QTY-1 LOW VOLTAGE ENTRY BOX. ORDER ADDITIONAL LOW VOLTAGE ENTRY BOX FSR PART NO. PWB-100-CBB. TERMINATE CONDUITS TO UPPER OR LOWER LOW-VOLTAGE ENTRY BOX AS INDICATED ON THE CONDUIT RISER DRAWINGS. [D] EQUIPMENT RACK WIREWAY RECESS WIREWAY INTO WALL WITH REMOVABLE COVER FACING OUT. TERMINATE CONDUITS TO WIREWAY INSIDE WALL SPACE. Consultant: [E] RACO JUNCTION BOXES W/RAISED DEVICE COVERS PROVIDE A RAISED SINGLE OR MULTI DEVICE COVER AS SPECIFIED OF APPROPRIATE DEPTH TO MATCH WALL THICKNESS. [F] CEILING SUSPENDED VIDEO PROJECTOR THE LOCATION OF THE AUDIOVISUAL, POWER AND NETWORK JUNCTION BOXES IN RELATION TO THE PROJECTION SCREEN IS CRITICAL. FOR VIDEO PROJECTOR INFRASTRUCTURE LAYOUT INFORMATION SEE SHEET AV002 AND REFERENCED DETAILS. [G] FB9(N1,P1) POKE-THRU WIREMOLD (LEGRAND) EVOLUTION 8AT 8" POKE THROUGH DEVICE. INTERIOR OPTIONS: PROVIDE QTY(2)#68REC INSERT PLATE2 FOR OUTSIDE (POWER) COMPARTMENTS. PROVIDE QTY(2) #8B INSERT PLATES FOR THE RIGHT AND CENTER MIDDLE COMPARTMENT, RESERVING THIS COMPARTMENT FOR AUDIOVISUAL USE. PROVIDE QTY1#8ACT6A DEVICE MOUNTING PLATE FOR THE LEFT MIDDLE (DATA) COMPARTMENT. BOTTOM OPTIONS: PROVIDE QTY(1)#175CHA BOTTOM HOUSING ASSEMBLY AND QTY(1)#5BLH BOTTOM HOUSING ASSEMBLY FOR THE OUTSIDE POWER COMPARTMENTS (TUNNELS BETWEEN COMPARTMENTS). PROVIDE QTY(1)#22CHA BOTTOM HOUSING ASSEMBLY (OR) QTY(1)#1125CHA 1-1/4" CONDUIT RECEIVER BOTTOM HOUSING ASSEMBLY (+) QTY1#1BLH BOTTOM HOUSING ASSEMBLY FOR THE RIGHT AND CENTER MIDDLE (AV) COMPARTMENT AS REQUIRED PER ROOM. PROVIDE QTY1#1125CHA 1-1/4" CONDUIT RECEIVER FOR THE LEFT MIDDLE (DATA) COMPARTMENT. COVER OPTIONS: VERIFY COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO INSTALLATION. [H] NETWORK OUTLETS FOR AUDIOVISUAL SYSTEMS NETWORK OUTLETS SHOWN ON THE DRAWINGS ARE REPRESENTATIVE OF NETWORK CONNECTIVITY REQUIREMENTS IN SUPPORT OF AUDIOVISUAL SYSTEMS. REFER TO THE STRUCTURED CABLING SYSTEM SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION. [I] POWER RECEPTACLES ADJACENT STANDARD NETWORK WALL OUTLETS N2 STANDARD NETWORK WALL OUTLETS SHOULD HAVE A DUPLEX POWER RECEPTACLE LOCATED WITHIN 36" OF THE TELECOMMUNICATIONS WALL OUTLET. IDEALLY, THE NETWORK OUTLET BOX WILL BE MOUNTED TO ONE SIDE OF A STUD, AND THE POWER BOX TO THE OPPOSITE SIDE OF THE BOX. SEE DETAIL X/Txx FOR DETAILS. [J] NO SUBSTITUTION NO KNOWN EQUIVALENT FOR THIS DEVICE DENOTES A FLOOR BOX CONTAINING NETWORK & POWER OUTLETS GENERAL NOTES         DESCRIPTION TECHNOLOGY SYSTEMS FLOOR BOX POWER TECHNOLOGY SYSTEMS POWER TECHNOLOGY SYSTEMS POWER FLAT PANEL DISPLAY POWER VIDEO PROJECTOR POWER PULL BOX MOTORIZED PROJECTION SCREEN POWER PROJECTOR POWER VIDEO PROJECTOR POWER REQUIREMENTS DUPLEX RECEPTACLE INSIDE FLOOR BOX DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE WORKBOX W/PWR CKT WORKBOS W/PWR CKT DUPLEX RECEPTACLE WORKBOX W/PWR CKT (2) 120V, 20A, I.G. RECEPTACLE (NEMA 5-20R) 120V, 20A, I.G. RECPTACLE (NEMA 5-20R) (2) 120V, 20A, DEDICATED CKT. I.G. (NEMA 5-20R) 120V, 20A, I.G. RECEPTACLE (NEMA 5-20R) 120V, 20A I.G. RECEPTACLE (NEMA 5-20R) 120V, 20A CKT. 120V, 20A, I.G. RECEPTACLE (NEMA 5-20R) 120V, 20A I.G. RECEPTACLE (NEMA 5-20R) TYPE CABLING # ALL NETWORK OUTLETS FOR AUDIOVISUAL SUPPORT REQUIRE ONE CAT6 DROP. N-NUMBER DESIGNATES BOX TYPE & MTG STYLE 4&5/AV501 7/AV501 1&4/AV502 1/AV502 4/AV502 DETAIL CEILING OUTLET WALL OUTLET COORDINATE WITH FLOOR BOX 18" AFF - FLUSH 18" AFF - FLUSH PART OF J11 18" ABOVE ACCESSIBLE CEILING TERMINATE AT J25 PER MFG INSTRUCTIONS PART OF J40 FLUSH IN ACCESSIBLE CEILING DRAWING REFERENCE SYMBOLS TELECOMMUNICATION OUTLET SYMBOLS LEGEND SYMBOL REFERENCE DETAIL MOUNTING STYLE AV000 SECTION SYMBOL DETAIL# / SHEET # # AV000 ELEVATION SYMBOL DETAIL# / SHEET # # AV000 RISER CONDUIT RISER DETAIL# / SHEET # DISPLAY TYPE X NOTES [I] [F] [F] [F] SUBSTITUTIONS THE MANUFACTURER AND MODEL OF JUNCTION BOXES NAMED IN THE TECHNOLOGY SYMBOLS LEGEND HAVE BEEN LISTED TO ESTABLISH THE DESIRED LEVEL OF QUALITY AND PERFORMANCE FOR EACH DEVICE. UNLESS OTHERWISE INDICATED, THE INSTALLING CONTRACTOR MAY SUBSTITUTE THESE DEVICES WITH EQUIVALENT PRODUCT BY OTHER MANUFACTURERS. DEVICE MOUNTING DEVICE SPECIFIED MOUNTING STYLE ELEVATIONS ARE "ON CENTER" UNLESS OTHERWISE NOTED. JUNCTION BOX COVERS UNLESS OTHERWISE DIRECTED, ALL JUNCTION BOXES MUST BE PROVIDED WITH A COVER. WHERE RAISED DEVICE COVERS ARE SPECIFIED IN THE SCHEDULE, MATCH COVER DEPTH TO WALL THICKNESS. WHERE JUNCTION BOXES ARE MOUNTED AT OR ABOVE FINISHED CEILING HEIGHT, INSTALL JUNCTION BOX WITH OPEN SIDE FACING DOWN. CONDUIT RUNS: ALL CONDUIT RUNS SHALL BE STEEL, THIN-WALL ELECTRICAL METALLIC TUBING (EMT) UNLESS OTHERWISE INDICATED. CONDUIT SIZES AND TERMINATIONS SHALL BE AS INDICATED ON THE TECHNOLOGY SYSTEMS INFRASTRUCTURE DRAWINGS. CONDUIT ROUTING IS AT CONTRACTOR'S DISCRETION BUT THE CONTRACTOR SHALL PROVIDE A PULL BOX IMMEDIATELY BEFORE AND AFTER ANY CONDUIT RUN SECTION CONTAINING TWO NINETY-DEGREE TURNS, OR ANY SINGLE RUN EXCEEDING FIFTY FEET IN LENGTH REGARDLESS OF WHETHER PULL BOXES ARE SHOWN ON THE DRAWINGS OR NOT. ALL CONDUIT RUNS SHALL BE PROVIDED WITH A PULL STRING. University of Wisconsin - Eau Claire P1 P2 P3 P4 P8 P9 P30 P31 FUNCTION Division of State Facilities SYM Department of Administration TYPE State of Wisconsin AUDIOVISUAL & TECHNICAL POWER SYMBOLS LEGEND TECHNOLOGY INFRASTRUCTURE VS. TECHNOLOGY SYSTEMS THESE TECHNOLOGY DRAWINGS INCLUDE ONLY INFRASTRUCTURE ELEMENTS NEEDED TO ACCOMMODATE THE PLANNED AUDIOVISUAL SYSTEMS. INFRASTRUCTURE ELEMENTS INCLUDE SUCH ITEMS AS PROJECTION SCREENS, CONDUIT, J-BOXES, CABLE PATHWAYS, BLOCKING, MOUNTING, POWER, NETWORK CONNECTIONS, ETC. THAT NEED TO BE COORDINATED WITH THE BASE BUILDING CONSTRUCTION AND SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR OR ITS SUBCONTRACTORS. AUDIOVISUAL SYSTEMS (I.E. SPECIFIC EQUIPMENT AND/OR INDIVIDUAL TECHNOLOGY COMPONENTS) ARE NOT INCLUDED HEREIN AND WILL BE SPECIFIED UNDER A SEPARATE, INDEPENDENT SET OF BID DOCUMENTS. WHILE SOME EQUIPMENT (SUCH AS FLAT PANEL DISPLAYS) ARE INDICATED IN THIS DRAWING SET, THESE ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. N11 FLOOR OUTLET CONDUIT STUBS: PROVIDE A NYLON BUSHING ON ALL CONDUIT STUBS AND NON-TERMINATED CONDUIT ENDS TO PROTECT WIRE PULLS. FURNISH INSTALL AC POWER SYSTEMS, COUNDUIT, RACEWAYS, ELECTRICAL BACK BOXES, JUNCTION BOXES, PULL BOXES, FLOOR BOXES, CABLE TRAYS, AND OTHER CABLING INFRASTRUCTURE GC/EC GC/EC LOW VOLTAGE AV INTERFACES FOR LIGHT DIMMING SYSTEMS (AT DIMMER SIDE), CONTROL CABLE PATHWAY TO AUDIOVISUAL CONTROL SYSTEM EQUIPMENT RACK GC/EC GC/EC LOW VOLTAGE AV INTERFACES FOR ROOM DARKENING SHADES (AT CONTROLLER SIDE), CONTROL CABLE PATHWAY TO AUDIOVISUAL CONTROL SYSTEM EQUIPMENT RACK GC/EC GC/EC UNISTRUT, THREADED ROD, SUPPORT CABLE, FASTENERS OR OTHER HARDWARE REQUIRED TO ATTACH AUDIOVISUAL WALL OR CEILING MOUNTS TO STRUCTURE GC GC SPECIFIED PROJECTOR CEILING TILE MOUNTS (SEE AV502, DETAILS 3 & 4) GC GC PROJECTION SCREENS GC GC BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED AUDIOVISUAL COMPONENTS GC GC ROUGH OR FINISHED TRIM, CASEWORK, MILLWORK, EQUIPMENT RACK PEDESTALS, STRUCTURAL WORK FOR SPECIAL CONSTRUCTION GC GC TELECOMMUNICATIONS CABLING AND TERMINATION SERVING AUDIOVISUAL SYSTEMS SC SC CUSTOM TELECOMMUNICATIONS CONNECTOR INSERT PLATES FOR FLOOR BOXES SC SC CUSTOM AUDIOVISUAL CONNECTOR INSERT PLATES FOR FLOOR BOXES AVC AVC INDOOR CABLING FOR VIDEO AND AUDIO SYSTEMS AVC AVC CABLE TERMINATIONS FOR VIDEO AND AUDIO SYSTEMS AVC AVC VIDEO AND AUDIO SYSTEM COMPONENTS (PROJECTORS, FLAT PANEL DISPLAYS, MOUNTS, LOUDSPEAKERS, AND ASSOCIATED ELECTRONICS AVC AVC GC GC AVC AVC DEDICATED COMPUTERS AND SOFTWARE O O PROGRAMMING AND LICENSING FEES IF APPLICABLE O O CLASSROOM INSTRUCTOR STATIONS FURNITURE FOR VIDEO AND AUDIO SYSTEMS - E.G. STAND ALONE EQUIPMENT RACKS, ROLLING CARTS FIRESTOPPING: PROVIDE THROUGH-PENETRATION FIRE STOP SYSTEMS TO PREVENT THE SPREAD OF FIRE THROUGH OPENINGS MADE IN FIRE-RATED WALLS OR FLOORS TO ACCOMMODATE PENETRATING ITEMS SUCH AS CONDUIT, CABLES AND CABLE RACEWAYS. FIRE STOP SHALL RESTORE FLOOR AND WALL TO ORIGINAL FIRE RATED INTEGRITY AND SHALL BE WATERPROOF. THE FIRE STOP SYSTEMS AND PRODUCTS SHALL HAVE BEEN TESTED IN ACCORDANCE WITH UL PROCEDURES AND MATERIALS SHALL BE UL CLASSIFIED AS MATERIALS FOR USE IN THROUGH-PENETRATION FIRE STOPS. THE FIRE STOP SYSTEM SHALL COMPLY WITH THE NEC AND WITH NFPA 101-LIFE SAFETY CODE (LATEST EDITION) AND SHALL BE MADE AVAILABLE FOR INSPECTION BY THE LOCAL INSPECTION AUTHORITIES PRIOR TO CABLE SYSTEM ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE FIRE RATING OF ALL WALLS AND FLOORS HAVING CABLING PENETRATIONS. COORDINATE SEALANT INSTALLATION WITH WORK OF OTHER TRADES. REFER TO GENERAL AND/OR ELECTRICAL SPECIFICATION SECTIONS FOR FURTHER MATERIAL AND INSTALLATION PARAMETERS. COORDINATE INSTALLATION WITH THE GENERAL CONTRACTOR ON SITE. FIRE STOP SYSTEMS SHALL BE UL CLASSIFIED TO ASTM E814 (UL1479) AND SHALL BE APPROVED BY A QUALIFIED PROFESSIONAL ENGINEER (P.E.), LICENSED IN THE STATE WHERE THE WORK IS TO BE PERFORMED. A DRAWING SHOWING THE PROPOSED FIRE STOP SYSTEM, STAMPED/EMBOSSED BY THE P.E. SHALL BE PROVIDED TO THE OWNER'S TECHNICAL REPRESENTATIVE PRIOR TO INSTALLING THE FIRE STOP SYSTEM(S). TECHNOLOGY SYMBOLS AND LENGENDS ITEM OR TASK GROUND COMMUNICATIONS SYSTEMS AND EQUIPMENT IN ACCORDANCE WITH ANSI/TIA/EIA-607 GROUNDING STANDARD AND APPLICABLE NEC REQUIREMENTS EXCEPT WHERE THE DRAWINGS OR SPECIFICATIONS EXCEED NEC REQUIREMENTS. ALL RACKS, METALLIC BACKBOARDS, CABLE SHEATHS, METALLIC STRENGTH MEMBERS, SPLICE CASES, CABLE TRAYS, ETC. ENTERING OR RESIDING IN TECHNICAL EQUIPMENT SPACES SHALL BE GROUNDED TO THEIR RESPECTIVE GROUND SYSTEM USING A MINIMUM #6 AWG SOLID COPPER BONDING CONDUCTOR AND COMPRESSION CONNECTORS. ALL WIRES USED FOR TECHNICAL POWER SYSTEMS GROUNDING PURPOSES SHALL BE IDENTIFIED WITH GREEN INSULATION OR IDENTIFIED AT EACH TERMINATION POINT WITH A WRAP OF GREEN TAPE. ALL CABLES AND BUS BARS SHALL BE IDENTIFIED AND LABELED "TECHNICAL POWER SYSTEM GROUND". Sheet Title: DIVISION OF RESPONSIBILITIES RELATED TO AUDIOVISUAL SYSTEMS New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin POWER RECEPTACLES: POWER RECEPTACLES INDICATED ON THE TECHNOLOGY INFRASTRUCTURE DRAWINGS ARE SHOWN FOR COORDINATION PURPOSES ONLY. REFER TO THE ELECTRICAL DRAWINGS FOR COMPLETE POWER LAYOUTS AND CIRCUITING DETAILS. Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 KEY AVC* = AUDIOVISUAL CONTRACTOR EC = ELECTRICAL CONTRACTOR GC = GENERAL CONTRACTOR O = OWNER SC = STRUCTURED CABLING CONTRACTOR *THE AVC WILL BE ENGAGED TO INTEGRATE THE SPECIFIED AUDIOVISUAL SYSTEMS (WHICH ARE NOT INCLUDED HEREIN – SEE GENERAL NOTES FOR CLARIFICATION). THIS ENGAGEMENT WILL BE UNDER A SEPARATE BID PACKAGE/RFP TO BE ISSUED AT A LATER DATE, WITH THE SUCCESSFUL BIDDER TO BE CONTRACTED DIRECTLY THROUGH THE OWNER. PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV001 12' TYPE PST-C PST-D PST-E PST-J PST-M 50" 65" 72 1/2" 120" 54" FLAT PANEL DISPLAY TYPE SCHEDULE ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS ALL DIMENSIONS IN INCHES / WEIGHT IN POUNDS (CH) CASE SIZE (CW) (CD) WEIGHT 7" 7" 7" 7" 7" 117" 129" 142" 210" 121" 9" 9" 9" 9" 9" 103 115 128 631 107 80" 104" 116" 192" 96" INSTALLATION OPERATION CEILING RECESSED CEILING RECESSED CEILING RECESSED CEILING RECESSED CEILING RECESSED BASIS OF DESIGN MOTORIZED MOTORIZED MOTORIZED MOTORIZED MOTORIZED IMAGE SURFACE MATERIAL DRAPER ACCESS SERIES V DRAPER ACCESS SERIES V DRAPER ACCESS SERIES V DRAPER ACCESS XL SERIES V DRAPER ACCESS SERIES V M1300 M1300 M1300 M1300 AT GREY CONTROL DETAIL BUILT-IN LVC BUILT-IN LVC BUILT-IN LVC BUILT-IN LVC BUILT-IN LVC 1/AV501 1/AV501 1/AV501 1/AV501 TYPE FPD-A FPD-B FPD-D FPD-E RS NOTE: 1. 2. 3. 4. NOTE: 1. SEE ROOM PROJECTION SCREEN SCHEDULE ON THIS SHEET FOR LOCATIONS. 2. PROJECTION SCREEN CONTROL SWITCHES, MOUNTING HARDWARE, CONDUITS AND ELECTRICAL PROVIDED BY G.C. 3. REFER TO DETAILS LISTED IN THE LEGEND FOR EACH PROJECTION SCREEN TYPE. IMAGE SIZE (ID) (IH) (IW) 52" 25" 45" 60" 29" 52" 47" 23" 41" 88" 46" 74" 4 1/2" 2" 4" CASE SIZE (CH) (CW) (CD) 27 5/16" 47 1/2" 4 1/2" 31 1/4" 54 1/8" 4 7/16" 24 3/4" 42 5/8" 4 3/8" 50" 78" 1" 3 1/2" 6 3/16" 1 3/16" WEIGHT 62 77 56 82 2 DETAIL 6-7/AV501 6-7/AV501 6-7/AV501 6-7/AV501 6-7/AV501 PROVIDID FOR COORDINATION ONLY SEE ROOM DISPLAY SCHEDULE ON THIS SHEET FOR LOCATIONS. REFER TO DETAILS LISTED IN THE SCHEDULE FOR EACH FLAT PANEL DISPLAY TYPE. BACKING, JUNCTION BOXES, CONDUIT AND ELECTRICAL PROVIDED BY G.C. FLAT PANEL DISPLAYS, MOUNTING HARDWARE, AND CABLING PROVIDED BY THE AUDIOVISUAL SYSTEMS CONTRACTOR. RA Project No.:1266.A IMAGE SIZE (IH) (IW) PROJECTION SCREEN / DISPLAY TYPE SCHEDULE Consultant: PROJECTION / DISPLAY ROOM & MOUNTING STYLE SCHEDULE ALL DIMENSIONS IN INCHES MOUNT STYLE 1108 1204 1204 1415 1415 1614 1614 1704 1704 1804 1804 1916 1916 1917 1917 1920 1920 1924 2304 2304 2420 2614 2614 2704 2704 2804 2804 2904 2916 2917 PST-C PST-E PST-E PST-J PST-J PST-J PST-J PST-E PST-E PST-E PST-E PST-E PST-M PST-D PST-D PST-E PST-E PST-E PST-E PST-E PST-C PST-E PST-E PST-E PST-E PST-E PST-E PST-C PST-E PST-D 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MS2 MS2 MS2 MS1 MS1 MS1 MS1 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 BLACK DROP 38" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 18" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 12" 6" 6" DISTANCE [D1] 131" 190" 190" 269" 269" 291" 291" 219" 222" 222" 222" 147" 150" 160" 147" 170" 170" 161" 202" 202" 189" 214" 214" 231" 231" 231" 231" 124" 199" 189" 139" 198" 198" 277" 277" 299" 299" 227" 230" 230" 230" 155" 160" 169" 156" 179" 179" 175" 217" 217" 194" 222" 222" 240" 240" 240" 240" 132" 211" 194" 2917 2917 2920 2920 2924 2927 2927 2931 2931 3115B 3314 3502 3504 3504 3714 3714 3814 3814 3815 3916 3920 3924 3931 4301 4308 4415 4612 4705 4712 4712 PST-D PST-D PST-E PST-E PST-E PST-E PST-E PST-E PST-E PST-C PST-C PST-C PST-C PST-C PST-E PST-E PST-D PST-D PST-E PST-E PST-E PST-E PST-E PST-C PST-C PST-C PST-M PST-C PST-C PST-C SCREEN/DISPLAY QTY MOUNT STYLE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 MS2 BLACK DROP DISTANCE [D1] 6" 6" 6" 6" 6" 6" 6" 12 1/2" 12 1/2" 6" 6" 12" 18" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 6" 12" 6" 6" DISTANCE [D1x] 139" 162" 203" 203" 213" 205" 205" 202" 202" 149" 177" 158" 151" 159" 222" 222" 159" 159" 215" 180" 180" 180" 178" 137" 137" 138" 150" 158" 123" 131" DISTANCE [D2] ROOM NO. 144" 170" 209" 209" 218" 210" 210" 207" 207" 155" 180" 166" 159" 168" 230" 230" 167" 167" 224" 188" 188" 188" 186" 151" 151" 146" 161" 166" 131" 139" 517 1000 1015 1102 1106 1108 1420 1804 1917 2002 2208 2300-2 2415 2804 2916 2917 3002 3015A 3027 3114 3115 3315 3406 3504 3614 3713 3814 3914 3916 3916 3920 3924 3931 4415 4906 VIDEO PROJECTOR MOUNTING STYLE DETAILS FOR MOUNTING STYLE TYPE MS1 PROJECT CEILING MOUNT SEE DETAIL 1&2/AV502 AND NOTES BELOW FOR MOUNTING STYLE TYPE MS2 PROJECTOR IN CEILING LAY-IN MOUNT SEE DETAIL 3&4/AV502 AND NOTES BELOW PROJECTION SCREEN / VIDEO PROJECTOR RELATIONSHIP NOTES: 1) [D1]: !!! CRITICAL DISTANCE !!! - D1 IS THE DISTANCE FROM THE PROJECTION SCREEN SURFACE TO THE CENTER OF THE PROJECTOR CEILING MOUNT ASSEMBLY. FPD-D RS FPD-D FPD-D FPD-B FPD-B RS FPD-A FPD-A FPD-B FPD-A FPD-D FPD-E RS FPD-B FPD-B FPD-B FPD-A FPD-D RS FPD-B FPD-D RS FPD-E FPD-A FPD-A FPD-D FPD-D FPD-A FPD-B FPD-B FPD-E FPD-E FPD-E FPD-E FPD-D FPD-D 5 10 1 1 1 1 1 2 2 2 10 2 2 1 1 2 2 11 2 1 1 1 1 4 3 6 1 1 9 2 2 1 2 2 4 1 1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 FPD-1 AFF 48" 48" 48" 48" 48" 48" 48" 48" 48" 72" 54" 48" 30" 48" 48" 72" 72" 54" 48" 48" 48" 48" 48" 66" 48" 48" 48" 48" 48" 48" 48" 30" 30" 30" 30" 48" 48" University of Wisconsin - Eau Claire SCREEN/DISPLAY QTY Division of State Facilities SCREEN/DISPLAY TYPE UNITS OF MEASUREMENTS ARE IN INCHES SCREEN/DISPLAY SCREEN/DISPLAY MOUNT TYPE QTY STYLE Department of Administration ROOM NO. UNITS OF MEASUREMENTS ARE IN INCHES DISTANCE DISTANCE ROOM SCREEN/DISPLAY [D1x] [D2] NO. TYPE ROOM DISPLAY SCHEDULE State of Wisconsin ROOM PROJECTION SCREEN SCHEDULE FLAT PANEL DISPLAY MOUNTING STYLE DETAILS 2) [D1x]: IS THE ALLOWABLE +/- VARIANCE IN THE DISTANCE OF [D1] TO ACCOMMODATE STRUCTURAL OR OTHER OBSTRUCTIONS. EXAMPLE: THE PROJECTOR MOUNT FOR ROOM 101, PROJECTION SCREEN TYPE-A CAN BE LOCATED BETWEEN 318" TO 354", ON SCREEN CENTERLINE FROM THE PROJECTION SCREEN SURFACE. CONTACT THE AUDIOVISUAL CONSULTANT IF CONDITIONS WILL NOT PERMIT THE PROJECTOR MOUNT TO BE LOCATED WITHIN THE SCREEN-TO-MOUNT DISTANCE SPECIFIED BY [D1] AND VARIABLE [D1x]. FOR MOUNTING STYLE TYPE FPD1 WALL MOUNTED FLAT PANEL DISPLAY SEE DETAIL 6&7/AV501 POWER & LOW-VOLTAGE JUNCTION BOX (TYPICAL). LOCATION RELATIVE TO SCREEN CASE MAY VARY BY SCREEN TYPE. VERIFY BEFORE INSTALLATION. J25/P9 P LV PROJECTOR SUPPORT ASSEMBLY CENTERPOINT SEE SHEET AV502 FOR DETAILS (CW) 6~12" (TYP.) (CW) (CH) J41 90° (IW) (SCREEN CENTERLINE) J40(N31,P30) 90° PROJECTION SCREEN CASE N30 P P8 OR P P8 P P31 !!!CRITICAL DISTANCE!!! (D1) DISTANCE FROM CENTER OF CASE PROJECTION SCREEN MOTOR ROLLER HOUSING Revisions: N30 POWER, AV, & NETWORK PULL BOXES FOR PROJECTOR (CD) POWER & LOW-VOLTAGE JUNCTION BOX (TYPICAL). LOCATION RELATIVE TO SCREEN CASE MAY VARY BY SCREEN TYPE. VERIFY BEFORE INSTALLATION. Sheet Title: CEILING MOUNTED VIDEO PROJECTION SCREEN (TYP.) ( AUDIENCE VIEW ) AUDIOVISUAL NOTES AND SCHEDULES CEILING MOUNTED VIDEO PROJECTION SCREEN & PROJECTOR LAYOUT (TYP.) New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 3) [D2]: IS THE ESTIMATED DISTANCE FROM THE PROJECTION WALL TO THE CENTER OF THE PROJECTOR CEILING MOUNT ASSEMBLY. BLACK DROP CEILING RECESSED MOTORIZED PROJECTION SCREEN LAY-IN OR HARD CEILING No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 2/ 5/ 2013 CB 1060 (IH) (IW) NOTE: DISTANCE (D1) IS CRITICAL. IF DISTANCE (D2) MUST BE INCREASED OR DECREASED FOR ANY REASON, DISTANCE (D1) MUST BE MAINTAINED. TO CENTER OF UNISTRUT ASSEMBLY Graphic Scale (D2) DISTANCE FROM WALL TO DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV002 CENTER OF UNISTRUT ASSEMBLY FINISHED WALL 1 TYPICAL PROJECTION SCREEN AV002 12" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' 12' B C D E F G H I J K RA Project No.:1266.A A Consultant: 3 1123 1125 1127 1500B J15 DN DN DN DN FPD-A P2 N2 J11(N3,P4) J3 3 AV304 ASSISTANT DIRECTOR 6 RISER 1119 STORAGE Room-2 1117 3-2 1 RETENTION COORDINATOR FPD-A N2 P2 J11(N3,P4) J3 AV401 160 SEAT LECTURE HALL AV402 7 AV303 RISER 1415 COMPUTER LAB 1420 University of Wisconsin - Eau Claire 1121 VESTIBULE 1115 1015 RETENTION COORDINTOR 1111 DN FB5(N1,P1) 1113 DN DN DN MAIN TELECOM ROOM J15 J9 1613 1100A J11(N3,P4) 2 MEN'S RESTROOM FPD-B Space UP UP J9 J15 J15 1110A 515 FB5(N1,P1) WORK ROOM RECEPTION 7 1106 Space 516 1000A ELEVATOR RISER WOMEN'S RESTROOM AV401 DN LACTATIONCUSTODIAL ROOM CLOSET J68 RS 1000 1410.A J4 N2 P2 J11(N3,P4) J16 1000C 3 AV301 RISER FPD-A P2 N2 J3 J11(N3,P4) 3 FPD-B FB5(N1,P1) FB5(N1,P1) 1 AV401 5 1 AV302 AV401 RESOURCE CENTER 4 BLUGOLD BEGINNINGS DN UP UP DN 1204 1108 J3 J11(N3,P4) N2 P2 FPD-A 1102 1411 J14 J16 72 SEAT CLASSROOM RISER 2 1600A 1410 DN LOBBY VESTIBULE 4 AV301 1110 FPD-D J11(N3,P4) STAIR A 2 1412 ELECT. CLOSET New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin ELEVATOR J14 N2 J4 P3 J12 Sheet Title: CYBER CAFE J12 GEAR UP HOT DESK AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR PLAN A GEAR UP DIRECTOR Division of State Facilities OMA DIRECTOR State of Wisconsin FINANCIAL SPECIALIST GEAR UP ASSISTANT DIRECTOR Department of Administration 3 Revisions: 1 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 1 Graphic Scale A B C D E F G H I J K AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR PLAN A 1/8" = 1'-0" A B N PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV101.A L M N O P Q RA Project No.:1266.A R FPD-D FACULTY RESOURCE Consultant: J11(N3,P4) Room-7 1931 RESTROOM Space 3-7 1929 511 Space 510 UPUP LOADING/ STORAGE 1927 1 AV301 45 SEAT CLASSROOM RISER 1924 J12 6 MECHANICAL AV405 1923 J8 FB5(N1,P1) FPD-A P2J3N2 J11(N3,P4) 4 AV301 DN J12 3 AV304 FB5(N1,P1) AV412 FPD-A N2 J3 P2 J11(N3,P4) 6 FB5(N1,P1) 5 DN 1920 J12 3 J9 FB5(N1,P1) 6 RISER N2 J3 P2 J11(N3,P4) DN AV405 P2 J11(N3,P4) J3 N2 4 AV404 7 AV302 FPD-A DN 4 FPD-A FPD-A RISER 1614 DN P2 J11(N3,P4) J3 N2 P2 ACTIVE J11(N3,P4) J3 LEARNING N2 CLASSROOM 1917 FPD-A J14 FILM VIEWING J15 N2J2 P3 FPD-A J11(N3,P4) N2 J3 P2 J11(N3,P4) N2 J3 P2 FPD-A J9 45 SEAT CLASSROOM J14 2 J14 1916 2 1 AV303 J9 J15 4 AV301 2 J15 N2J2P3J9 J15 RISER FB5(N1,P1) FB5(N1,P1) 5 FB7 AV403 AV402 DN DN DN 72 SEAT CLASSROOM FB7 RISER J15 J12 J12 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 140 SEAT LECTURE HALL 60 SEAT CLASSROOM FPD-A N2 J3 P2 J11(N3,P4) FB5(N1,P1) State of Wisconsin RISER J12 8 AV303 6 AV403 RISER 8 FB7 J14 DN FB7 FB7 FB5(N1,P1) J9 J14 AV403 J14 J14 N2 J6 P3 7 FB7 72 SEAT CLASSROOM 1704 FB7 1804 FB7 UP UP FPD-D FB7 DN DN FB7 DN DN J11(N3,P4) FB7 FB7 J11(N3,P4) J12 J11(N3,P4) FPD-B FPD-B J12 University of Wisconsin - Eau Claire DN P2J3N2 J11(N3,P4) 3 Sheet Title: DN 1923A AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR PLAN B DN FPD-A 1923B Division of State Facilities J15 J9 EMERGENCY DISTRIBUTION Department of Administration 3 MAIN DISTRIBUTION Revisions: VESTIBULE 1900B 1 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 2 10/ 17/ 2012 CB 1034 1 Graphic Scale L M N O P Q R AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY A B N KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV101.B B C D E F G H I J K RA Project No.:1266.A A Consultant: 3 2123 2217 STUDENT SERVICE COORD. STUDENT SERVICE COORD. STUDENT SERVICE COORD. STUDENT SERVICE COORD. 2219 2221 2223 2421 2423 2425 2427 State of Wisconsin J12 STUDENT SERVICE COORD. 2117 C.F.W.E. DIRECTOR'S OFFICE TUTORING LAB-2 STUDENT SERVICE COORD. AV405 3 TUTORING LAB C.F.W.E. COORDINATOR OFFICE 2100 STUDENT SERVICE COORD. TUTORING LAB 2113 2200 J68 J8 RS ELEVATOR WORK ROOM UP UP 2208-1 2214 2114 Space J12 520 Space 2216 FB12 2 AV302 J12 519 517 60 SEAT CLASSROOM FB9(N1,P1) FB9(N1,P1) 2414 RISER Space TELECOM ROOM 505 2208 J11(N3,P4) TESTING ROOM 4 AV303 FPD-D 2 J11(N3,P4) 2412 RISER 1 2304 FPD-E MATH LAB 2104 2000A 2415 CUSTODIAL CLOSET 3 AV302 RESTROOM J9 RISER STAIR A MEETING ROOM 2613 ELECT. CLOSET RECEPTION Space AV405 J68 RS N2 J4 J16 P2 2100A MATH LAB-1 2 FPD-B J11(N3,P4) 2413 GROUP TUTORING FB12 RISER 2417 GROUP TUTORING 2 FB9(N1,P1) 1 AV301 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 2001 2420 2419 2300-2 2115 BALCONY 45 SEAT CLASSROOM WOMEN'S RESTROOM AV406 2609 2204 2 AV302 DN DN Space 2116 SSD RECEPTION N2 P3 N2 P3 FPD-D J11(N3,P4) J4 J11(N3,P4) J4 FPD-D 2106 FPD-D 2 AV302 J11(N3,P4) RISER P2 J4 N2 2 AV302 RISER RISER MEN'S RESTROOM 1 RISER HALL 2 AV302 AV405 2410 FPD-E 522 J11(N3,P4) 2 AV302 DN DN MATH LAB RISER FACULTY TESTING COORDINATOR OFFICE ROOM TESTING ROOM TESTING ROOM 2108 2110 2112 J12 J12 J12 University of Wisconsin - Eau Claire 2121 STUDENT SERVICE COORD. 2206 J12 Sheet Title: 2119 DIRECTOR OFFICE STUDENT SERVICE COORD. AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR PLAN A DIRECTOR OFFICE STUDENT SERVICE COORD. Division of State Facilities RESOURCE ROOM STUDENT SERVICE COORD. Department of Administration 3 Revisions: COLLABORATIVE LEARNING No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 2002 1 1 Graphic Scale A A B C D E F G H I J B K N AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR PLAN A 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV102.A L M N O P Q RA Project No.:1266.A R FB9(N1,P1) J9 FB12 Consultant: 60 SEAT CLASSROOM AV407 2 DN DN 4 AV303 2931 RISER J12 UP UP 45 SEAT CLASSROOM 2924 N2 P2 J11(N3,P4) J3 J12 N2 P2 J11(N3,P4)J3 N2 P2 J11(N3,P4)J3 FB9(N1,P1) 60 SEAT CLASSROOM 1 AV301 RISER FB12 J12 J9 5 2927 P2 J11(N3,P4) J3 N2 FB12 2 AV414 FB9(N1,P1) 1 2 AV304 4 FB9(N1,P1) RISER P2 J11(N3,P4) J3 N2 3 J11(N3,P4) J3 N2 P2 4 AV303 FPD-A P2 N2 J3 J11(N3,P4) FPD-A RISER FPD-A 60 SEAT CLASSROOM N2 J11(N3,P4) J3 RISER 2920 WOMEN'S RESTROOM P2 100 SEAT CLASSROOM FB12 5 AV405 P2 J3 J11(N3,P4) N2 FPD-A J12 2614 N2 J11(N3,P4) J3 FB9(N1,P1) FB12 FPD-A J15 J3 J11(N3,P4) N2 5 AV410 P2 1 ACTIVE LEARNING CLASSROOM J60 UP FPD-D J12 ELECT. CLOSET FPD-A 2919 J9 UP AV406 J9 2917 3 4 FB9(N1,P1) P2 2 N2 J11(N3,P4) J3 FB12 FPD-A P2 FB9(N1,P1) 2923 FPD-A J11(N3,P4) J11(N3,P4) N2J3 P2 FPD-A N2 J3 P2 FPD-A J11(N3,P4) N2 J3 P2 9 AV301 AV CLOSET FPD-B FPD-B J11(N3,P4) J12 J11(N3,P4) FB7 FB7 2917A RISER FB7 2 P3 J6 N2 J9 FB12 J12 J12 J9 4 AV303 4 FB7 AV304 1 AV304 FB12 RISER RISER RISER FB9(N1,P1) N2 J6 P3 60 SEAT CLASSROOM FB9(N1,P1) 6 3 AV406 FB7 60 SEAT CLASSROOM AV406 FB7 2 2804 N2J2 P3 VENDING 2913 FB7 FB7 1 2916 AV407 FB7 9 J12 J12 FB7 N2J8P3 J6 2 AV301 FB7 FB12 FB9(N1,P1) J9 7 RISER FB7 2 45 SEAT CLASSROOM FB7 2704 FB7 FB7 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 4 AV303 UP UP AV406 FB7 FB7 STAIR D FB12 2900A DN DN FB7 FB7 J11(N3,P4) J12 J11(N3,P4) FPD-B FPD-B J12 FB9(N1,P1) CONFERENCE ROOM J42 2904 RS J68 OPEN STUDY Revisions: 2900B 1 Sheet Title: J15 University of Wisconsin - Eau Claire P2 J11(N3,P4) J3 N2 P2 AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR PLAN B J11(N3,P4) J3 N2 P2 Division of State Facilities P2 J3 J11(N3,P4) N2 N2 J11(N3,P4) J3 Department of Administration N2 J6 P3 FPD-A State of Wisconsin 3 FB12 J8 3 AV406 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 1 Graphic Scale L M N O P Q R A AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY B N KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV102.B B C D E F G H I J K L RA Project No.:1266.A A Consultant: AV407 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 3119 3123 3127 3131 3219 3223 3227 3231 3319 3323 3327 3329 3419 3423 3519 3523 3619 3027 PROFESSIONAL STAFF OFFICE RS J68 3023 FUTURE FUTURE FACULTY FACULTY 3029A 3121 3121 6 AV302 FULL TIME FACULTY TUTORING LAB-1 3129 WORK ROOM 3015A 3021 FPD-E N2 J4 J11(N3,P4) P2 2300-1 3029 RECEPTION FUTURE FACULTY 3015 5 2 AV301 3019 J16 RECEPTION J42 J8 ELEVATOR 3017 3100A 3115A 1 3417 3521 3330 FB12 J16 FPD-E N2 J4 J11(N3,P4) P2 STUDENT ORGANIZATION CONFERENCE ROOM FPD-E P2 J11(N3,P4)J4 N2 3309 3115B CUSTODIAL TELECOM ROOM 3414 3613 J16 ELECT. CLOSET N2 P3 J6 2 AV408 WORK ROOM 3315 FB9(N1,P1) J68 GENERAL STORAGE 2 FPD-E P2 J11(N3,P4) J4 N2 OFFICE STORAGE INSTRUCTIONAL MEDIA CENTER 3215 RISER ASSOCIATE DEAN'S OFFICE RISER AV407 RS SECURE STORAGE J16 3211 J68 RS FPD-D J11(N3,P4) New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin PROFESSIONAL HALL STAFF OFFICE SECURE STORAGE 2 RESTROOM 3412 UP UP GROUP STUDY Space 3114 523 FPD-D RS J68 5 AV413 FPD-D J3 J11(N3,P4) 7 J12 AV301 J11(N3,P4) WOMEN'S RESTROOM STORAGE VISITING FACULTY HOT DESK OFFICE 3112 3210 3310 J16 CENTER/INSTITUTE FOR EDUCATIONAL LEADERSHIP RISER RECEPTION 3102 3208 DN DN AV CART STORAGE SERVERY 3312 3609 3406.A 6 AV303 3314 VISITING FACULTY HOT DESK J4 P3 N2 J8 RESOURCE 3306 RISER PROJECT ROOM TECHNOLOGY LAB 3406.B 3406 P2 P2 J11(N3,P4) J3 N2 P3 N2 P3 FPD-D N2 J11(N3,P4) J4 J11(N3,P4) J4 FPD-D AV407 7 READING SPECIALIST PROJECT ROOM AV413 J3 N2 RS FPD-A N2P3 J6N2P3 J6 P2 J11(N3,P4) J3 N2 3206 HALL 3002 3214 3104 4 J68 3406.C COLLABORATIVE LEARNING ASSOCIATE DEAN'S OFFICE 6 AV301 PROJECT ROOM FB12 SEMINAR ROOM RISER ACADEMIC PROGRAM DIRECTOR ASSISTANT CERTIFICATION OFFICER ACADEMIC ADVISOR RECRUITER/ ADVISOR COMMUNITY LIASON OFFICE 3106 3108 3110 3202 3204 4 6 FPD-A 3406.D FPD-A P2 N2 J3 J11(N3,P4) Revisions: P2 FB9(N1,P1) P2 J11(N3,P4) J3 N2 FPD-A 6 3502 P2 J11(N3,P4) J3 N2 9 AV302 FPD-A RISER OFFICE AV407 AV408 5 3 FB9(N1,P1) 9 AV301 8 P2 J11(N3,P4) J3 N2 FPD-A J8 J3 N2 FPD-A FB12 SEMINAR ROOM 3504 RISER J42 3406.E J11(N3,P4) P2 J3 J12 N2 FPD-A P2 J11(N3,P4)J3 N2 AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR PLAN A 1/8" = 1'-0" D E F G H I J Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 2 1/ 17/ 2013 RFI 214 RESPONSE 3 2/ 5/ 2013 CB 1060 P2 J11(N3,P4) J3 N2 Graphic Scale A C Date: J3 N2 FPD-A 1 B No. P2 1 A University of Wisconsin - Eau Claire FULL TIME FACULTY Sheet Title: MEETING ROOM DEPARTMENT CHAIR AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR PLAN A J5 N2 P3 RISER Division of State Facilities FPD-B J11(N3,P4) 3 FB9(N1,P1) 3025 3 5 AV302 Department of Administration 4 DEAN'S OFFICE State of Wisconsin 3 K PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY L B N KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV103.A L M N O P Q RA Project No.:1266.A R J12 FPD-E J11(N3,P4) FPD-E OPEN STUDY J11(N3,P4) Consultant: 3900D SCIENCE METHODS STAIR C DNDN 3931 3900C 2 AV413 1 3 5 AV301 FB9(N1,P1) RISER FB12 FPD-E J11(N3,P4) FPD-E J11(N3,P4) FPD-E J8 J11(N3,P4) J12 EDUCATION METHODS LAB PREP STORAGE 3931A 3924 3931B 5 AV301 RISER FULL TIME FACULTY 5 3835 AV411 6 FULL TIME FACULTY RESOURCE LIBRARY 3831 FB9(N1,P1) FB12 J8 FPD-E J11(N3,P4) 3925 3 3 FULL TIME FACULTY FULL TIME FACULTY MATERIALS STORAGE 3619 3623 3719 3723 3727 3731 3819 3823 3827 FPD-E J11(N3,P4) 5 AV301 J12 MATH METHODS RISER 3 3920 AV411 J12 FUTURE FACULTY TESTING ROOM HOT DESKS 3621 3721 3725 3817 RESTROOM 4 3923 FB9(N1,P1) 3715 BUILDING SUPPORT 3614 8 AV302 AV413 J68 RS 2 5 5 J12 J11(N3,P4) J3 7 FPD-D AV301 RISER J16 FB12 GENERAL BUILDING STORAGE FB12 J8 SPECIAL EDUCATION METHODS 3917 3916 1 GROUP STUDY RS J68 3919 FB9(N1,P1) RISER J12 J11(N3,P4) J3 7 FPD-D AV301 J16 RISER FPD-B J11(N3,P4) J12 J11(N3,P4) FPD-B FB9(N1,P1) ELECT. CLOSET 1 3813 AV413 AV409 3815 3717 GROUP STUDY J11(N3,P4) 3921 FB12 J8 FPD-E New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin RECEPTION SUPPORT RESTROOM COMPUTER CLASSROOM 2 AV411 3713 AV CLOSET 3910 P3 J6 N2 J9 2 AV304 FB12 RISER 5 FB9(N1,P1) P2 J11(N3,P4) J3 N2 N2 P2 J11(N3,P4)J3 J9 FPD-A AV414 6 FPD-A FB9(N1,P1) FPD-A FPD-A J11(N3,P4) J3 N2 P2 J11(N3,P4) J3 N2 J12 FPD-A FPD-E J12 3912 7 P2 J3J11(N3,P4) N2 5 FPD-A P2 J11(N3,P4)J3 N2 P2 J3J11(N3,P4) N2 FPD-A P2 J11(N3,P4)J3 N2 P2 J11(N3,P4) J3 N2 P2 J11(N3,P4) RS FB12 J8 EQUIPMENT STORAGE P2 J3J11(N3,P4) N2 FPD-A P2 J11(N3,P4)J3 N2 J11(N3,P4) J3 N2 P2 J12 N2 J11(N3,P4) J3 P2 3 AV409 4 P2 FB9(N1,P1) RISER J68 3714 8 5 AV303 N2 J6 P3 FPD-A 60 SEAT CLASSROOM FB12 J11(N3,P4) J3 N2 N2 P2 J11(N3,P4)J3 2 2 9 AV301 FB12 FPD-A J43 RISER 3914 FB9(N1,P1) FB9(N1,P1) ACTIVE LEARNING CLASSROOM 3814 DNDN CONFERENCE ROOM N2 J11(N3,P4) J3 P2 FPD-B J11(N3,P4) UP Revisions: UP 4 AV302 RISER FPD-A J12 FPD-B J11(N3,P4) N2 J11(N3,P4) J3 P2 4 AV410 Sheet Title: GRAD ASSISTANTS University of Wisconsin - Eau Claire FULL TIME FACULTY AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR PLAN B FULL TIME FACULTY Division of State Facilities FULL TIME FACULTY Department of Administration DEPARTMENT CHAIR State of Wisconsin FULL TIME FACULTY INSTRUCTIONAL MEDIA CART STORAGE No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 2/ 5/ 2013 CB 1060 FB9(N1,P1) FB9(N1,P1) FPD-A J6 P3 N2 J11(N3,P4) J3 N2 FPD-A P2 1 1 Graphic Scale A L M N O P Q B R N AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV103.B RA Project No.:1266.A Consultant: DEPARTMENT CHAIR FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 4115 4117 4119 4121 4217 4219 4303 4307 4311 4315 4319 4417 4419 4503 4507 4511 4603 AV402 4600B 4415 4107 INSTRUCTIONAL ACADEMIC STAFF FT INSTRUCTIONAL ACADEMIC STAFF PT 4213 4214 ELEVATOR 6 GRAD ASSISTANTS 3 AV303 4322 OFFICE STORAGE 4100A RISER 4312 INSTRUCTIONAL ACADEMIC STAFF FT INSTRUCTIONAL ACADEMIC STAFF PT 4211 4212 WORK ROOM FUTURE FACULTY INSTRUCTIONAL ACADEMIC STAFF 4105 4209 4210 FUTURE FACULTY 4207 4208 TELECOM ROOM 4414 4613 FB9(N1,P1) RESTROOM 4412 N2J3P3 J8 J6 P3 N2 J11(N3,P4) J12 J11(N3,P4) J42 J42 WOMEN'S RESTROOM J8 FB9(N1,P1) 4 4609 3 3 AV402 AV412 RISER DN DN CUSTODIAL CLOSET FPD-D J11(N3,P4) 4 AV302 INSTRUCTIONAL ACADEMIC STAFF PT FPD-D P3 J3 J11(N3,P4) N2 J42 FB9(N1,P1) FB9(N1,P1) 4 CONFERENCE ROOM 1 8 FB12 AV301 RISER LIBRARY/RESEARCH CENTER 4301 4308 STUDENT ORG. FUTURE FACULTY INSTRUCTIONAL ACADEMIC STAFF PT 4112 4205 4206 University of Wisconsin - Eau Claire 7 STUDENT ORGANIZATION STAIR F HUMANITIES RESEARCH LAB 5 VENDING RECEPTION 4408 4508 FB9(N1,P1) J4P3 N2 RS J68 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY DEPARTMENT CHAIR FULL TIME FACULTY 4104 4106 4110 4114 4116 4202 4204 4302 4306 4310 4314 4318 4402 4404 4510 4602 Sheet Title: 4216 UP UP AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR PLAN A 4215 N2 J6 P3 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 4111 INSTRUCTIONAL ACADEMIC STAFF PT Division of State Facilities 4109 INSTRUCTIONAL ACADEMIC STAFF FT State of Wisconsin ELECT. CLOSET FULL TIME FACULTY Department of Administration 4113 Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 2 2/ 8/ 2013 CB 1060 AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR PLAN A 1/8" = 1'-0" Graphic Scale A B N PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV104.A RA Project No.:1266.A Consultant: FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY INSTRUCT. ACADEMIC STAFF FT 4603 4607 4703 4707 INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT FULL TIME FACULTY FULL TIME FACULTY 4711 4715 4817 4819 4821 4823 4919 4921 FULL TIME FACULTY 4923 J68 4815 4816 ELECT. CLOSET FULL TIME FACULTY 4915 4920 2 STORAGE CONFERENCE ROOM LIBRARY/FILM VIEWING STUDIO J42 4917 INSTRUCT. ACADEMIC STAFF PT FUTURE FACULTY 4813 4814 INSTRUCTIONAL ACADEMIC STAFF PT FUTURE FACULTY STUDENT ORGANIZATION 4811 4812 4911 FUTURE FACULTY TEACHING ASSISTANTS 4810 4909 J6 P3 N2 FULL TIME FACULTY State of Wisconsin FB9(N1,P1) 4918 4705 4612 N2P3 J6 3 J14 4 FULL TIME FACULTY 4916 AV403 1 1 AV303 J14 RISER J6 P3 N2 2 FB9(N1,P1) FB12 University of Wisconsin - Eau Claire 4605 RISER INSTRUCTIONAL ACADEMIC STAFF PT FULL TIME FACULTY 4914 2 LANGUAGE LABORATORY J14 4712 VISITING FACULTY INSTRUCTIONAL ACADEMIC STAFF PT 4808 4907 5 J14 J14 J14 J8 FULL TIME FACULTY 4912 RISER WORK ROOM GROUP J16 5 AV413 STUDY FPD-D 4906 J3 J11(N3,P4) 7 J12 AV301 VISITING FACULTY J9 J12 4606 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 2 AV303 4806 DN RISER DN RS J68 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 4602 4604 4702 4706 4710 4714 4802 4804 4902 4904 4908 4910 Sheet Title: J14 AV412 AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR PLAN B FB12 1 INSTRUCTIONAL ACADEMIC STAFF PT Division of State Facilities AV404 VISITING FACULTY J8 9 AV302 Department of Administration RS Revisions: AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR PLAN B 1/8" = 1'-0" No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 2 11/ 20/ 2012 CB 1042 3 2/ 5/ 2013 CB 1060 Graphic Scale A B N PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV104.B B C D E F G H I J K RA Project No.:1266.A A Consultant: 3 1121 1123 1125 1127 J27 J27 ASSISTANT DIRECTOR N30 P8 J40(N31,P30) PST-J 1119 STORAGE Room-2 1117 3-2 J25 P9 RETENTION COORDINATOR 1 N40 AV401 160 SEAT LECTURE HALL 3 AV304 AV402 6 N40 COMPUTER LAB 1415 RISER 1420 University of Wisconsin - Eau Claire GEAR UP DIRECTOR Division of State Facilities OMA DIRECTOR State of Wisconsin FINANCIAL SPECIALIST GEAR UP ASSISTANT DIRECTOR Department of Administration 3 1115 N30 P8 J40(N31,P30) PST-J RETENTION COORDINTOR GEAR UP HOT DESK 1113 1111 N40 J20 P9 J25 MAIN TELECOM ROOM N40 2 2 1412 ELECT. CLOSET J25P9 1110A P9J25 PST-E PST-E J20 WORK ROOM ELEVATOR 7 1110 RECEPTION AV401 1106 WOMEN'S RESTROOM 4 AV301 RISER 1600A 1410 J27 N40 VESTIBULE P31 J41 P8 N30 1000C BLUGOLD BEGINNINGS 1108 1102 1 3 AV301 RISER AV401 5 1 AV302 RISER 2 AV401 J25 P9 RESOURCE CENTER 3 P31 J41 P8 N30 P8 P31 J41 N30 72 SEAT CLASSROOM PST-C J27 1204 4 J20 N40 Sheet Title: MEN'S RESTROOM New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 1100A AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR CEILING PLAN A 1613 ELEVATOR Revisions: N40 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 J41 1 1 Graphic Scale A A B C D E F G H I J B K N AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR CEILING PLAN A 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV201.A L M N O P Q RA Project No.:1266.A R Consultant: FACULTY RESOURCE 1931 LOADING/ STORAGE 1927 N40 1 AV301 N30 RISER P8 J41 P31 PST-E 6 MECHANICAL 1923 45 SEAT CLASSROOM P9 J25 J20 J27 N40 3 MAIN DISTRIBUTION EMERGENCY DISTRIBUTION 1923B 1923A AV405 1924 N40 J27 J27 3 N30 P8 J41 P31 PST-E J27 PST-J J25 P9 4 J40(N31,P30) 140 SEAT LECTURE HALL P31 P8 3 AV304 1614 AV412 6 RISER P9 J25 N30 J41 ACTIVE LEARNING CLASSROOM PST-J 5 7 AV302 J40(N31,P30) RISER 4 AV301 RISER N30 P8 J41 P31 PST-E 4 1917 N30 P8 AV405 AV404 University of Wisconsin - Eau Claire N40 PST-D N30 P8 N40 J25P9 J20 P9 J25 3 J20 N40 N30 J41 6 P31 P8 N40 J20 N40 J25 2 J25 P9 PST-E J25 P9 P9J25 2 J20 J20 4 AV301 AV402 P9J25 PST-E PST-E 1916 PST-E PST-E 6 J27 5 RISER AV403 J27 N40 J27 8 8 AV303 J41 P8 N30 P31 P31J41 P8 N30 J41 P8 N30 P31 2 RISER P9 J25 AV403 PST-M P9 J25 11" CRITICAL DISTANCE 7 P31 J41 P8 N30 72 SEAT CLASSROOM 72 SEAT CLASSROOM 1704 1804 J27 N40 N30 P8 J41 P31 J41 P8 P31 AV403 N30 J20 RISER 1 AV303 J27 N40N40 Sheet Title: 45 SEAT FILM VIEWING CLASSROOM P9 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin PST-D AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR CEILING PLAN B J27 State of Wisconsin J27 Division of State Facilities 1920 J25 P9 Department of Administration 60 SEAT CLASSROOM Revisions: N40 VESTIBULE 1900B 1 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 1 Graphic Scale A L M N O P Q B R N AUDIOVISUAL INFRASTRUCTURE FIRST FLOOR CEILING PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV201.B B C D E F G H I J K RA Project No.:1266.A A Consultant: 3 2123 2217 STUDENT SERVICE COORD. STUDENT SERVICE COORD. STUDENT SERVICE COORD. STUDENT SERVICE COORD. 2219 2221 2223 2421 2423 2425 2427 N40 MATH LAB-3 C.F.W.E. DIRECTOR'S OFFICE 2208-3 TUTORING LAB-2 STUDENT SERVICE COORD. 45 SEAT CLASSROOM N30 P8 J41 P31 2419 AV405 2300-2 3 TUTORING LAB 2115 2420 C.F.W.E. COORDINATOR OFFICE 2100 STUDENT SERVICE COORD. TUTORING LAB 2113 2200 1 AV301 RISER J20 2417 P9 J25 N40 2 ELEVATOR 2100A J27 AV405 GROUP TUTORING MEETING ROOM 2413 2415 CUSTODIAL CLOSET N40 N40 TELECOM ROOM 2414 2613 N40 2 WORK ROOM GROUP TUTORING 2114 2214 MATH LAB-1 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 2117 N40 State of Wisconsin N40 STUDENT SERVICE COORD. 2 ELECT. CLOSET 2208-1 RESTROOM J25 P9 J25 P9 2216 J20 2412 J27 PST-E PST-E RECEPTION WOMEN'S RESTROOM 1 MATH LAB 2104 TESTING ROOM 2609 2208 AV406 4 AV303 RISER 2204 AV405 MEN'S RESTROOM 1 N30 P8 J41 P31 SSD RECEPTION 2106 TESTING ROOM TESTING ROOM 2108 2110 MATH LAB FACULTY TESTING COORDINATOR OFFICE ROOM 2112 2410 N30 P8 J41 P31 60 SEAT CLASSROOM 2304 2206 COLLABORATIVE LEARNING University of Wisconsin - Eau Claire 2121 STUDENT SERVICE COORD. N40 Sheet Title: 2119 DIRECTOR OFFICE STUDENT SERVICE COORD. AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR CEILNG PLAN A DIRECTOR OFFICE STUDENT SERVICE COORD. Division of State Facilities RESOURCE ROOM STUDENT SERVICE COORD. Department of Administration 3 Revisions: N40 2002 1 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 1 Graphic Scale A A B C D E F G H I J B K N AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR CEILING PLAN A 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV202.A L M N O P Q RA Project No.:1266.A R J27 4 AV303 J25 P9 J20 N40 RISER Consultant: N30 P8 J41 P31 PST-E AV407 60 SEAT CLASSROOM 2 P9 J25 2931 N30 P8 J41 P31 PST-E N40 N40 1 AV301 45 SEAT CLASSROOM RISER J27 J20 2 AV304 J25 P9 N40 N30 P8 J41 P31 PST-E 2924 RISER N30 P8 J41 P31 5 N40 PST-E 3 60 SEAT 2 CLASSROOM AV414 1 2927 P9 J25 AV406 J20 J27 P9 J25 4 N30 P8 J41 P31 PST-E 3 3 N40 J27 PST-E N40 4 AV303 N30 P8 J41 P31 RISER N30 P8 J41 P31 PST-E PST-D 100 SEAT CLASSROOM J25 P9 5 60 SEAT CLASSROOM N40 J25 P9 2917 J25 P9 P9 J25 WOMEN'S RESTROOM 2920 P31 N30 P8 J41 PST-E 2923 AV405 2614 P31 N30P8 J41 N30 P8 J41 P31 PST-E P9 J25 ACTIVE LEARNING CLASSROOM 4 J20 P9 J25 PST-D 9 AV301 RISER 5 2 4 AV303 N40 AV410 RISER MEN'S RESTROOM P31 N30 P8 J41 1 AV406 University of Wisconsin - Eau Claire P31 N30 P8 J41 J27 Division of State Facilities J27 State of Wisconsin N40 Department of Administration N40 J20 ELECT. CLOSET 2921 2919 3 N40 P9J25 P31 N30 P8 J41 2 J25 P9 J25 P9 P9 J25 P9 J25 PST-E PST-E PST-E J20 PST-E VENDING 3 4 AV303 1 AV304 AV406 RISER 2913 N40 RISER 2 N30 P8 J41 P31 N30 P8 J41 P31 AV407 J20 J27 PST-E 9 J25P9 J25 P9 PST-C PST-C J20 N30 P8J41P31 2 1 6 AV406 4 AV304 P31 N30 P8 J41 RISER J20 J27 2916 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 45 SEAT CLASSROOM N40 N30 P8 J41 P31 2 AV301 60 SEAT CLASSROOM 2704 2804 7 AV406 RISER J27 60 SEAT CLASSROOM P9 J25 N30 P8 J41 P31 CONFERENCE ROOM J27 2904 N40 N40 N40 Sheet Title: J27 PST-D AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR CEILING PLAN B N40 J20 Revisions: N40 N40 1 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 1 Graphic Scale A L M N O P Q B R N AUDIOVISUAL INFRASTRUCTURE SECOND FLOOR CEILING PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV202.B B C D E F G H I J K RA Project No.:1266.A A Consultant: AV407 3 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 3119 3123 3127 3131 3219 3223 3227 3231 3319 3323 3327 3329 3419 3423 3519 3523 3619 MEETING 5 AV302 ROOM RISER PROFESSIONAL STAFF OFFICE 3027 N40 3023 PROFESSIONAL HALL STAFF OFFICE SECURE STORAGE FUTURE FACULTY 3029A 3121 6 AV302 FULL TIME FACULTY WORK ROOM 3015A 3021 OFFICE STORAGE WORK ROOM 3417 3521 3330 2 AV408 1 2300-1 3029 J25 P9 3215 N40 3015 INSTRUCTIONAL MEDIA CENTER RECEPTION 5 RECEPTION FUTURE FACULTY RISER TUTORING LAB-1 3129 SECURE STORAGE University of Wisconsin - Eau Claire FULL TIME FACULTY J20 3315 AV407 CONFERENCE ROOM RISER ASSOCIATE DEAN'S OFFICE ELEVATOR GENERAL STORAGE 3017 3100A 3115A J41 P31 N30 P8 STUDENT ORGANIZATION 3115B 3309 CUSTODIAL TELECOM ROOM 3414 3613 ELECT. CLOSET J27 3211 2 2 RESTROOM 3412 N40 ELEVATOR N40 3600A N40 15 GROUP STUDY 3114 SK9 CB AV413 1060 WOMEN'S RESTROOM STORAGE VISITING FACULTY HOT DESK OFFICE 3112 3210 3310 7 AV301 SERVERY 3312 AV CART STORAGE 3609 MEN'S RESTROOM 3406.A RISER 3410 RECEPTION 3102 VISITING FACULTY HOT DESK RESOURCE 3306 3208 3314 COLLABORATIVE LEARNING READING SPECIALIST 3002 3406 3406.B 3214 J27 N40 N40 AV407 P31 J41 P8 N30 HALL 3104 PROJECT ROOM 7 P9 J25 PROJECT ROOM AV413 4 J25 P9 3406.C 3206 ASSOCIATE DEAN'S OFFICE J20 CENTER/INSTITUTE FOR EDUCATIONAL LEADERSHIP TECHNOLOGY LAB J27 PST-C 6 AV301 PST-C SEMINAR ROOM J20 3502 PROJECT ROOM N30 P8J41 P31 6 4 SEMINAR ROOM AV408 5 P31 N30 P8 ASSISTANT CERTIFICATION OFFICER ACADEMIC ADVISOR RECRUITER/ ADVISOR COMMUNITY LIASON OFFICE 3106 3108 3110 3202 3204 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 2 2/ 5/ 2013 CB 1060 3504 RISER ACADEMIC PROGRAM DIRECTOR Revisions: J41 6 3406.D Sheet Title: 2 AV301 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 3019 AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR CEILING PLAN A DEPARTMENT CHAIR Division of State Facilities 3 3025 Department of Administration 4 DEAN'S OFFICE State of Wisconsin 3 J27 AV407 N30 P8 J41 P31 2 AV301 8 RISER PST-C OFFICE 3406.E 9 AV301 J20 PST-C RISER P9J25 J25 P9 1 1 Graphic Scale A A B C D E F G H I J B K N AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR CEILING PLAN A 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV203.A L M N O P Q RA Project No.:1266.A R N40 SCIENCE METHODS OPEN STUDY 3931 Consultant: 3900D J27 P8 N30 J41P31 2 AV413 3 5 AV301 1 RISER J20 PST-E J25 P9 N40 LAB PREP EDUCATION METHODS 3931A 3924 5 AV301 RISER FULL TIME FACULTY P8 5 P31 J41 N30 J27 3835 AV411 6 N40 FULL TIME FACULTY RESOURCE LIBRARY 3831 J20 PST-E 3925 P9 J25 3 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY MATERIALS STORAGE 3619 3623 3719 3723 3727 3731 3819 3823 3827 N40 5 AV301 MATH METHODS RISER 3920 3 AV411 P8 J41 P31 N30 J27 GRAD ASSISTANTS FUTURE FACULTY TESTING ROOM HOT DESKS COMPUTER CLASSROOM 3621 3721 3725 3817 3815 4 J27 N40 P31 J41 N30 P8 PST-E RECEPTION 3717 AV409 RISER BUILDING SUPPORT ELECT. CLOSET 1 J21 3813 N40 TELECOM ROOM 3613 N40 GROUP STUDY GROUP STUDY N40 3713 7 AV301 3614 PST-E 7 AV301 GENERAL BUILDING STORAGE J20 J25 P9 SPECIAL EDUCATION METHODS 3917 RISER RISER 2 N40 3919 3916 N40 N40 N40 1 P8 J41 P31 N30 AV411 AV403 N40 N40 J25 P9 N40 N40 N40 2 2 J27 2 5 AV303 RISER PST-E P9 J25 J25 P9 N40 J25 P9 J20 PST-E 3912 5 8 AV414 P9 J25 EQUIPMENT STORAGE PST-D J20 PST-E J20 7 2 AV304 RISER 6 ACTIVE LEARNING CLASSROOM 5 J27 3 AV409 J27 2 J41N30 P31 P8 3814 P31 J41 N30 P8 CONFERENCE ROOM 9 AV301 4 P31 J41 N30 P8 SEMINAR ROOM J41 N30 P31 P8 J41 N30 P31 P8 3504 Revisions: 3914 RISER 60 SEAT CLASSROOM Sheet Title: 3616 P9 J25 8 AV302 3715 J20 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin VENDING SUPPORT University of Wisconsin - Eau Claire FULL TIME FACULTY AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR CEILING PLAN B FULL TIME FACULTY Division of State Facilities DEPARTMENT CHAIR State of Wisconsin FULL TIME FACULTY INSTRUCTIONAL MEDIA CART STORAGE Department of Administration 3 4 AV410 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 2 2/ 5/ 2013 CB 1060 3714 4 AV302 PST-D P9J25 RISER P9 J25 1 1 Graphic Scale A L M N O P Q B R N AUDIOVISUAL INFRASTRUCTURE THIRD FLOOR CEILNG PLAN B 1/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV203.B RA Project No.:1266.A Consultant: C D E F G H I J K L 3 3 DEPARTMENT CHAIR FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 4115 4117 4119 4121 4217 4219 4303 4307 4311 4315 4319 4417 4419 4503 4507 4511 4603 STORAGE 4109 4123 4111 INSTRUCTIONAL ACADEMIC STAFF FT INSTRUCTIONAL ACADEMIC STAFF PT INSTRUCTIONAL ACADEMIC STAFF PT INSTRUCTIONAL ACADEMIC STAFF PT 4215 4216 4316 4320 7 STUDENT ORGANIZATION AV402 EQUIP. HUMANITIES RESEARCH LAB 5 STAIR F 4400A 4600B 4416 4415 4107 ELEVATOR INSTRUCTIONAL ACADEMIC STAFF FT INSTRUCTIONAL ACADEMIC STAFF PT 4213 4214 6 GRAD ASSISTANTS GRAD ASSISTANTS 4322 OFFICE STORAGE 4100A 4321 INSTRUCTIONAL ACADEMIC STAFF FT INSTRUCTIONAL ACADEMIC STAFF PT 4211 4212 CUSTODIAL CLOSET TELECOM ROOM 4414 4613 Space 3 AV303 4312 2 J27 J41 P8 N30 P31 University of Wisconsin - Eau Claire ELECT. CLOSET Division of State Facilities FULL TIME FACULTY GENERAL BUILDING STORAGE Department of Administration N40 State of Wisconsin 4113 551 RISER 2 N40 RESTROOM PST-C 4412 P9 J25 ELEVATOR 4600A 4210 PST-C PST-C 4 MEN'S RESTROOM 3 3 AV402 AV412 RECEPTION FUTURE FACULTY INSTRUCTIONAL ACADEMIC STAFF PT 4207 4208 4102 4609 8 AV301 1 4410 RISER N30 J41 P31 P8 N30 4 J41 P31 P8 LIBRARY/RESEARCH CENTER STUDENT ORG. FUTURE FACULTY INSTRUCTIONAL ACADEMIC STAFF PT 4112 4205 4206 CONFERENCE ROOM J27 4308 4 AV302 RISER VENDING RECEPTION 4408 4508 4301 J20 J27 STORAGE 4508A N40 N40 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY COLLABORATIVE LEARNING DEPARTMENT CHAIR FULL TIME FACULTY 4104 4106 4110 4114 4116 4202 4204 4302 4306 4310 4314 4318 4402 4404 4502 4510 4602 Sheet Title: 4209 WOMEN'S RESTROOM J25 P9 AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR CEILING PLAN A 4105 J25 P9 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin WORK ROOM FUTURE FACULTY INSTRUCTIONAL ACADEMIC STAFF Revisions: 1 1 C D E F G H I J K No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 L AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR CEILING PLAN A 1/8" = 1'-0" Graphic Scale A B N PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV204.A RA Project No.:1266.A Consultant: L M N O P Q 3 3 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY INSTRUCT. ACADEMIC STAFF FT 4603 4607 4703 4707 INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT INSTRUCT. ACADEMIC STAFF FT FULL TIME FACULTY FULL TIME FACULTY 4711 4715 4817 4819 4821 4823 4919 4921 FULL TIME FACULTY AV404 1 P9 J25 J20 INSTRUCTIONAL ACADEMIC STAFF PT 4815 4816 4705 4605 J27 2 P8 J41 P31 N30 FULL TIME FACULTY 4915 4920 STORAGE PST-C 9 AV302 ELECT. CLOSET 4917 INSTRUCT. ACADEMIC STAFF PT FUTURE FACULTY 4813 4814 FULL TIME FACULTY 4918 RISER 2 N40 J27 3 4 J20 AV403 FUTURE FACULTY STUDENT ORGANIZATION 4811 4812 4911 FULL TIME FACULTY 4916 1 AV303 1 2 INSTRUCTIONAL ACADEMIC STAFF PT University of Wisconsin - Eau Claire VISITING FACULTY INSTRUCTIONAL ACADEMIC STAFF PT Division of State Facilities CONFERENCE ROOM State of Wisconsin N40 Department of Administration 4923 RISER 2P8 P31 J41 N30 FULL TIME FACULTY FUTURE FACULTY J27 4914 2 AV303 5 P8 4612 N30 J41 P31 J41 P31 N30 P8 LANGUAGE PST-M PST-C P9 J25 11" CRITICAL DISTANCE P9 J25 RISER J20 VISITING FACULTY INSTRUCTIONAL ACADEMIC STAFF PT 4808 4907 FULL TIME FACULTY 4912 LABORATORY 4712 WORK ROOM 4606 PST-C VISITING FACULTY GROUP STUDY 4806 4906 P9J25 N40 N40 N40 FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY FULL TIME FACULTY 4602 4604 4702 4706 4710 4714 4802 4804 4902 4904 4908 4910 1 1 Sheet Title: AV412 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 2 AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR CEILING PLAN B 4810 LIBRARY/FILM VIEWING STUDIO Revisions: L M N O P No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 2 2/ 5/ 2013 CB 1060 Q AUDIOVISUAL INFRASTRUCTURE FOURTH FLOOR CEILNG PLAN B 1/8" = 1'-0" Graphic Scale A B N PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY KEY PLAN 0' 2' 4' 8' 12' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV204.B (1)3/4"C (1)1-1/4"C TO LIGHTING CONTROL (1)3/4"C (1)1-1/4"C J20 A N CEILING J25 A P J41 N30 P31 P8 PROJECTOR J27 P9 A P A M A N CEILING J20 A P J25 P9 A P LOUDSPEAKERS (SEE PLAN FOR QUAN.) N40 N J27 M A LOUDSPEAKERS SCREEN J41 N30 P31 P8 PROJECTOR CEILING SCREEN (1)3/4"C N40 N CEILING CEILING CEILING J12 A CAMERA (2)1-1/4"C (1)3/4"C N3 P4 J11 N A FLAT PANEL HALLWAY (1)3/4"C RA Project No.:1266.A (1)3/4"C HALLWAY (1)3/4"C (1)3/4"C (2)1-1/4"C J8 A J8 SCREEN SWITCH A SCREEN SWITCH FLOOR N2 P3 N (OR) AS INDICATED ON PLAN FB5(N1,P1) FB12 A (1)2"C FLOOR J6 J68 A ROOM SCHEDULER A (1)2"C N1 (1)1-1/4"C A (1)1-1/4"C FLOOR (1)1-1/4"C (1)3/4"C (1)3/4"C A N1 J20 A N P J41 N30 P31 P8 PROJECTOR J25 A P J41 N30 P31 P8 PROJECTOR P9 A P J25 M SCREEN (1)3/4"C P9 A P J27 M A N CEILING SCREEN J25 P9 A P (1)3/4"C (1)1-1/4"C (1)3/4"C J27 M A J20 CEILING SCREEN J41 N30 P31 P8 PROJECTOR A BLUGOLD BEGINNINGS 1102 RISER NTS (1)3/4"C A P FLOOR N1 (2)1-1/4"C (1)3/4"C J20 CEILING FB5(N1,P1) FLOOR 3 AV301 (1)1-1/4"C (1)1-1/4"C Consultant: P3 N2 J4 N A 2 CONFERENCE ROOM TYPE 1 RISER AV301 NTS TO SHADE & LIGHTING CONTROL (100, 140, 160 SEAT ROOMS ONLY) J68 A ROOM SCHEDULER J41 A FB9(N1,P1) A 1 TYPICAL 45 CLASSROOM RISER AV301 NTS CEILING FB12 FLOOR FB9(N1,P1) A A N1 A A N (1)3/4"C J42 A A N CEILING A P J25 (1)3/4"C P9 A P J41 N30 P31 P8 PROJECTOR J27 M A CEILING SCREEN LOUDSPEAKERS (SEE PLAN FOR QUAN.) (1)3/4"C (1)3/4"C (2)1-1/4"C (2)1-1/4"C ELECTRONIC WHITEBOARD J9 J8 A A SCREEN SWITCH ELECTRONIC WHITEBOARD (TYP. OF 2) (2)1-1/4"C (3931 ONLY) (1)1-1/4"C N2 P3 J4 N A (1)1-1/4"C FB12 FLOOR FB9(N1,P1) A FB5(N1,P1) FLOOR N3 P4 J11 N A ELECTRONIC WHITEBOARD (1)1"C (1)1-1/4"C A SCREEN SWITCH J8 (1)3/4"C N3 P4 J11 N A FLOOR A (1)2"C FLOOR FLOOR FLOOR University of Wisconsin - Eau Claire N3 P4 J11 N A N1 A N1 A 6 TYPICAL METHODS RISER AV301 NTS AV301 CENTER/INSTITUTE FOR EDUCATIONAL LEADERSHIP 3314 RISER NTS (1)1-1/4"C (1)3/4"C TO LIGHTING CONTROL (1)3/4"C (1)3/4"C (1)1-1/4"C (1)3/4"C J20 J27 A N N40 N CEILING N40 N CEILING P J20 A J41 N30 P31 P8 PROJECTOR J25 P9 A P J27 M CEILING A CEILING SCREEN LOUDSPEAKERS A N A A N P J41 N30 P31 P8 PROJECTOR (2917 ONLY) A N P J41 N30 P31 P8 PROJECTOR J25 A P P9 A P J41 N30 P31 P8 PROJECTOR (2)1-1/4"C J25 M P9 A P SCREEN J25 M P9 A P SCREEN M CEILING SCREEN (2917 ONLY) CEILING (1)3/4"C (1)3/4"C J12 A CAMERA (1)3/4"C AV CLOSET 2917A or 3910 or IN-ROOM RACK (3)1-1/4"C (1)1"C (1)1-1/4"C J8 HALLWAY J11 N3 P4 N A FLAT PANEL (1)1-1/4"C J12 A J42 A J16 A (1)1"C (1)3/4"C A SCREEN SWITCH (1)3/4"C A J9 (J60 IN 2917) (1)3/4"C J68 A ROOM SCHEDULER J4 N2 P3 A N (1)1"C J3 A FLOOR FB12 FB9(N1,P1) A A FLOOR 7 GROUP STUDY RISER AV301 NTS FLOOR (1)2"C 8 AV301 LIBRARY/RESEARCH CENTER 4301 RISER NTS N3 P4 J11 N A A FLOOR FLOOR CENTER OF ROOM PODS (SEE PLAN FOR QUANTITY) FB9(N1,P1) A FB12 CENTER OF ROOM PODS (SEE PLAN FOR QUANTITY) FB9(N1,P1) A N1 (1)2"C A INSTRUCTOR FB9(N1,P1) FB12 A N1 (1)2"C A (1)2"C FLAT PANEL (SEE PLANS FOR QUAN.) (1)1"C Sheet Title: 5 TYPICAL STANDARD CLASSROOM RISER AV301 NTS New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 4 AUDIOVISUAL ROOM RISER DIAGRAMS (1)3/4"C Division of State Facilities J12 A Department of Administration J12 A CAMERA State of Wisconsin J15 A LOUDSPEAKER (TYP. OF 2, 72-SEAT ONLY) Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 2/ 5/ 2013 CB 1060 J6 N2 P3 N A N2 P2 J3 N A (SEE PLANS FOR QUAN.) FLOOR (1)1-1/4"C N1 N1 9 TYPICAL ACTIVE LEARNING CLASSROOM RISER - UPPER FLOORS AV301 NTS PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY (2)1-1/4"C Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV301 12' (1)1-1/4"C (1)3/4"C J20 A N CEILING J25 A P P9 A P J40 N30 P30 P8 PROJECTOR N40 N M CEILING CEILING CEILING SCREEN (1)3/4"C CEILING (1)3/4"C N3 P4 J11 N A FLAT PANEL J12 A CAMERA (TYP. OF 5 ROOMS) (1)1-1/4"C (1)1"C N3 P4 J11 N A FLAT PANEL (TYP OF 2) J41 A TOUCHPANEL (1)1-1/4"C (1)1"C SSD RECEPTION HALLWAY TESTING ROOMS J41 A (1)3/4"C (1)1-1/4"C J3 N2 A N (TYP OF 2) P2 P3 J4 N2 A N P3 (1)1-1/4"C FB5(N1,P1) FLOOR A N CEILING J4 N2 A N Consultant: (1)1-1/4"C FB9(N1,P1) A FLOOR 2 AV302 (1)1-1/4"C (1)1-1/4"C FLOOR RESOURCE CENTER 1108 RISER NTS J68 A ROOM SCHEDULER P2 N2 J4 N A FLOOR A N1 A 1 AV302 RA Project No.:1266.A CEILING J14 A LOUDSPEAKER (TYP OF 2) FLOOR N1 FLOOR 3 MEETING ROOM 2415 RISER AV302 NTS SSD RECEPTION AND TESTING ROOMS RISER NTS (1)3/4"C J25 P9 A P P J41 N30 P31 P8 PROJECTOR N40 N J27 A M SCREEN N40 N CEILING LOUDSPEAKERS CEILING CEILING (1)3/4"C CEILING CEILING (4306 ONLY) J68 A ROOM SCHEDULER J6 P3 N2 N A (1)2"C FB9(N1,P1) FLOOR A FB9(N1,P1) A N1 FB9(N1,P1) A N1 FLOOR (1)1"C J16 A J5 (1)1-1/4"C A (1)2"C FLOOR N1 FB9(N1,P1) A 4 CONFERENCE ROOM 3914/4308 RISER AV302 NTS ELECTRONIC WHITEBOARD N3 P4 J11 N A P2 N2 J4 N A FLOOR N1 ELECTRONIC WHITEBOARD N3 P4 J11 N A (1)1"C J16 A (1)1-1/4"C P2 N2 J4 N A ELECTRONIC WHITEBOARD N3 P4 J11 N A (1)1"C J16 A (1)1-1/4"C P2 N2 J4 N A (1)1"C J16 A (1)1-1/4"C P2 N2 J4 N A FLOOR 5 MEETING ROOM 3027 RISER AV302 NTS FLOOR 6 INSTRUCTIONAL MEDIA CENTER 3315 RISER AV302 NTS (1)3/4"C (1)1-1/4"C TO LIGHTING CONTROL (1)1-1/4"C J20 A N CEILING A N P J41 N30 P31 P8 PROJECTOR J25 A P P9 A P J41 N30 P31 P8 PROJECTOR J25 M SCREEN P9 A P (1)1-1/4"C (1)3/4"C J27 SCREEN J20 A M LOUDSPEAKERS A N CEILING CEILING P A J25 P9 A P J41 N30 P31 P8 PROJECTOR J27 A M A N CEILING CEILING J20 A P J41 N30 P31 P8 PROJECTOR SCREEN LOUDSPEAKERS (1)3/4"C J27 J25 A LOUDSPEAKERS P9 A P N40 N M CEILING SCREEN (1)3/4"C (1)3/4"C CAMERA J12 A (3)1-1/4"C HALLWAY N3 P4 J11 N A (1)3/4"C J9 N2 P3 N FLOOR J2 A A IN-ROOM EQUIPMENT RACK INSTRUCTOR FB5(N1,P1) FB5(N1,P1) FLAT PANEL (SEE PLANS FOR QUAN.) (1)1"C (1)1-1/4"C (2)1-1/4"C 7 AV302 ACTIVE LEARNING CLASSROOM 1917 RISER NTS (2)1-1/4"C (1)3/4"C J8 A SCREEN SWITCH (1)1"C J42 A N2 P2 J3 N A (SEE PLANS FOR QUAN.) J8 A SCREEN SWITCH (1)1"C FLOOR FLOOR A N1 A (2)1-1/4"C (2)1-1/4"C A N1 A INSTRUCTOR FB9(N1,P1) FB12 A A (1)2"C (1)1-1/4"C 8 COMPUTER CLASSROOM 3815 RISER AV302 NTS FLOOR FLOOR FB9(N1,P1) A N1 N2 P3 N FB12 J6 J68 A ROOM SCHEDULER Sheet Title: (1)1-1/4"C ELECTRONIC WHITEBOARD N3 P4 J11 N A (1)1-1/4"C J68 A ROOM SCHEDULER University of Wisconsin - Eau Claire (1)1"C State of Wisconsin (1)1-1/4"C (1)1"C P3 N2 N HALLWAY FLAT PANEL AUDIOVISUAL ROOM RISER DIAGRAMS HALLWAY A SCREEN SWITCH J43 A N3 P4 J11 N A New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin J8 (1)3/4"C Division of State Facilities FLAT PANEL (1)3/4"C N3 P4 J11 N A FLAT PANEL Department of Administration CAMERA N3 P4 J11 J12 A N A Revisions: A No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 FLOOR A N1 (1)2"C (3)1-1/4"C 9 CONFERENCE ROOM 4705 / SEMINAR ROOM 3502 RISER AV302 NTS Graphic Scale PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV302 12' (1)3/4"C (1)1-1/4"C (1)1-1/4"C J20 A N CEILING A N P J41 N30 P31 P8 PROJECTOR (1916 ONLY) P J25 A P9 A P J41 N30 P31 P8 PROJECTOR J25 M P9 A P J12 A J27 M CEILING A CEILING PROJECTION LOUDSPEAKERS SCREEN (1916 ONLY) PROJECTION SCREEN J14 LOUDSPEAKER A (TYP. OF 7) A N P J41 N30 P31 P8 PROJECTOR TO LIGHTING CONTROL (1)3/4"C A N P J27 A J20 A J25 P9 A P J41 N30 P31 P8 PROJECTOR P9 A P J25 M SCREEN (1)3/4"C J25 P9 A J27 A P M CEILING SCREEN A N CEILING P J41 N31 P30 P8 PROJECTOR M CEILING SCREEN RA Project No.:1266.A (1)3/4"C (1)3/4"C (1)1-1/4"C TO LIGHTING CONTROL (1)3/4"C TO LIGHTING CONTROL J12 A CAMERA CAMERA (1916 ONLY) (1)1-1/4"C (1)3/4"C (1)3/4"C (1)3/4"C (2)1-1/4"C (2)1-1/4"C (1)3/4"C (1)1-1/4"C (1)1"C N3 P4 J11 N A (1)3/4"C J9 (1)1"C FLAT PANEL A N2 P3 N (1)1"C J6 A N2 P3 N 1 TYPICAL LIBRARY/FILM VIEWING STUDIO RISER AV303 NTS A N1 (1)2"C A (3)1-1/4"C A N P J41 N30 P31 P8 PROJECTOR A P J41 N30 P31 P8 PROJECTOR P9 A P J25 M P9 A P J20 SCREEN (1)3/4"C J15 A LOUDSPEAKER (SEE PLAN FOR QUANTITY) SCREEN A N A CEILING J27 M (1)3/4"C (1)1-1/4"C J25 A P P9 A P J41 N30 P31 P8 PROJECTOR A CEILING J27 M A CEILING SCREEN LOUDSPEAKERS (SEE PLAN FOR QUAN.) (1)1"C J12 A CAMERA (2)1-1/4"C (1)3/4"C CAMERA N3 P4 J11 J12 N A A (3)1-1/4"C FLAT PANEL DISPLAY CAMERA J12 A N3 P4 J11 N A (1)3/4"C (1)1-1/4"C A A (1)2"C FB9(N1,P1) (1)1-1/4"C (1)1"C (1)1"C FB12 A (1)2"C A N1 A (1)1-1/4"C FB12 FB9(N1,P1) A FLOOR 4 TYPICAL UPPER FLOOR LECTURE HALL AND STANDARD CLASSROOM RISER AV303 NTS ELECTRONIC WHITEBOARD A SCREEN SWITCH FLOOR FB12 N3 P4 J11 N A J8 FLAT PANEL DISPLAY J9 FLOOR State of Wisconsin A N CEILING J25 TO LIGHTING CONTROL (1)3/4"C TO LIGHTING CONTROL (LECTURE HALL ONLY) J21 J20 FB9(N1,P1) A A N1 (1)2"C (1)2"C FLOOR N1 5 SPECIAL METHODS RISER AV303 NTS (1)1-1/4"C (1)3/4"C A N CEILING CEILING CEILING CEILING A N P J41 N30 P31 P8 PROJECTOR J41 N30 P31 P8 PROJECTOR CEILING N3 P4 J11 N3 P4 J11 N N A CONFIDENCE MONITORS N (1)1-1/4"C P2 N2 J3 N A FLOOR 6 TECHNOLOGY LAB 3406 RISER AV303 NTS FLAT PANEL DISPLAY N3 P4 J11 A N (1)1-1/4"C P2 N2 J3 N A FLAT PANEL DISPLAY N3 P4 J11 FLAT PANEL DISPLAY N3 P4 J11 A N N A (1)1-1/4"C (1)1-1/4"C A N P2 N2 J3 N A FLOOR 7 COMPUTER LAB 1420 RISER AV303 NTS J27 M SCREEN A CEILING LOUDSPEAKERS (SEE PLAN FOR QUAN.) J12 A CAMERA (TYPICAL OF 3) (1)3/4"C Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 J9 (1)1-1/4"C A SCREEN SWITCH J2 P2 N2 J3 N A A FB7 TYPICAL OF 12 (1)1-1/4"C FLOOR (2)1-1/4"C FLOOR M P9 A P (1)3/4"C A N2 P3 N P2 N2 J3 N A J25 (2)1-1/4"C (1)1-1/4"C FLAT PANEL DISPLAY N3 P4 J11 P9 A P SCREEN (1)3/4"C J15 A LOUDSPEAKER (TYP. OF 2) A J25 A P TO LIGHTING & SHADE CONTROL (1)3/4"C J20 FLAT PANEL DISPLAY N3 P4 J11 N1 3 HUMANITIES RESEARCH LAB 4415 RISER AV303 NTS (1)3/4"C (1)3/4"C FLOOR (1)2"C 2 LANGUAGE LABORATORY 4712 RISER AV303 NTS (1)3/4"C FB9(N1,P1) FLOOR University of Wisconsin - Eau Claire A N1 A FLOOR Sheet Title: A FB12 AUDIOVISUAL ROOM RISER DIAGRAMS (1)1-1/4"C FLOOR FB9(N1,P1) (1)1-1/4"C A Division of State Facilities FLOOR FLOOR N2 P3 J3 N A J6 N2 P3 N A FB5(N1,P1) (1916 ONLY) (1)1-1/4"C J3 A Department of Administration J6 SCREEN SWITCH New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin N2 P3 N SCREEN A SWITCH J9 (J8 IN 4612) Consultant: J42 J8 A A SCREEN TOUCHPANEL SWITCH FLOOR FB5(N1,P1) A N1 A 8 72 SEAT CLASSROOM WITH DISTANCE EDUCATION AV303 NTS PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY FLOOR Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV303 12' (1)3/4"C (1)3/4"C (1)1-1/4"C TO LIGHTING CONTROL J20 N3 P4 J11 N A J41 N30 P31 P8 PROJECTOR M SCREEN (1)3/4"C J15 A LOUDSPEAKER (SEE PLAN FOR QUANTITY) N3 P4 J11 N A J25 P9 A P J27 M A CEILING SCREEN (1)1-1/4"C J27 A N A CEILING J20 A N P J41 N30 P31 P8 PROJECTOR LOUDSPEAKERS (SEE PLAN FOR QUAN.) J25 A P P9 A P J41 N30 P31 P8 PROJECTOR J25 M P9 A P SCREEN J12 A CAMERA SCREEN (1)3/4"C CEILING Consultant: N3 P4 J11 N A J9 A J9 (J60 IN 2917) J6 N2 P3 N A FB7 (TYPICAL OF 10) FB12 FLOOR FB9(N1,P1) A FLOOR A N1 A (1)2"C CENTER OF ROOM POSITION FB9(N1,P1) FLOOR A (1)1-1/4"C 2 AV304 DISTANCE LEARNING CLASSROOM RISER NTS FB12 A A (1)2"C (1)2"C (1)1"C J6 N2 P3 or IN-ROOM RACK N A 2972 N2 P2 J3 N A (SEE PLANS FOR QUAN.) INSTRUCTOR FB9(N1,P1) A (2)1-1/4"C FLAT PANEL (SEE PLANS FOR QUAN.) FLOOR (1)1-1/4"C N1 (2)1-1/4"C 60 SEAT CLASSROOM WITH FUTURE ACTIVE LEARNING RISER NTS (1)3/4"C (1)1-1/4"C TO SHADE & LIGHTING CONTROL (1)3/4"C N1 FB12 AV CLOSET 3910 (2)1-1/4"C A SCREEN SWITCH (1)1"C A CAMERA (1)3/4"C (1)3/4"C M SCREEN (2917 ONLY) J12 AV CLOSET 2917A (2)1-1/4"C (1)1-1/4"C M (1)3/4"C P9 A P (1)3/4"C CONFIDENCE MONITORS TO LIGHTING CONTROL (1)3/4"C (1)1-1/4"C CEILING J40(N31,P30) PROJECTOR A N J40(N31,P30) PROJECTOR J20 P8 N30 P N J25 A P9 A P M SCREEN (1)3/4"C J15 A LOUDSPEAKER (TYP. OF 2, LECTURE HALL ONLY) J25 P9 A P J20 J27 M A A N CEILING SCREEN CEILING P J41 N30 P31 P8 PROJECTOR (FUTURE) LOUDSPEAKERS (SEE PLAN FOR QUAN.) A N J25 A P J41 N30 P31 P8 PROJECTOR M P9 A P J27 M SCREEN (FUTURE) A CEILING LOUDSPEAKERS (SEE PLAN FOR QUAN.) (1)3/4"C J12 A CAMERA (1)3/4"C N3 P4 J11 N3 P4 J11 N N A J12 A CAMERA (TYPICAL OF 3) A (2)1-1/4"C (3)1-1/4"C J9 J9 A SCREEN SWITCH J2 SCREEN SWITCH N2 P3 N FB7 (TYPICAL OF 9) FB5(N1,P1) FLOOR A (2)1-1/4"C FLOOR (1)1-1/4"C A N1 A FB12 A (1)2"C 4 AV304 (1)3/4"C (1)3/4"C A 3 FIRST FLOOR LECTURE HALL RISER AV304 NTS J25 SCREEN CONFIDENCE MONITORS FLOOR P9 A P State of Wisconsin A N P8 N30 P N FB9(N1,P1) A FLOOR N1 45 SEAT CLASSROOM DISTANCE LEARNING ENABLED RISER NTS New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 1 AV304 J25 University of Wisconsin - Eau Claire J41 N30 P31 P8 PROJECTOR A P P9 A P Sheet Title: P J25 AUDIOVISUAL ROOM RISER DIAGRAMS CEILING A N Division of State Facilities A N (2)1-1/4"C (1)3/4"C (1)3/4"C Department of Administration (1)1-1/4"C RA Project No.:1266.A TO LIGHTING CONTROL (1)1-1/4"C Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 Graphic Scale PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV304 12' RA Project No.:1266.A 44" 71" 49" Consultant: FPD-B FPD-A J11(N3,P4) J11(N3,P4) J16 54" 48" 54" 18" 1 AV401 2 AV401 Elevation BluGold 1102 North Wall 3/8" = 1'-0" P2 J4 N2 P2 3 AV401 Elevation BlueGold 1102 West Wall 3/8" = 1'-0" J3 N2 18" Elevation Resource Center 1108 North Wall 3/8" = 1'-0" 33" 72" 73" 35" 31" J3 90" N218" J11(N3,P4) J16 48" 5 AV401 Elevation Resource Center 1108 South Wall 3/8" = 1'-0" 58" 30" 126" 144" 126" J11(N3,P4) 56" 54" 18" 4 AV401 FPD-A Elevation Resource Center 1108 East Wall 3/8" = 1'-0" N2 J4 P3 N2 6 AV401 J3 P2 18" J15 N2 J3 P2 18" Elevation Computer Lab 1420 East Wall NTS 87" 6" PROJECTION SCREEN TYPE PST-E 54" University of Wisconsin - Eau Claire P2 FPD-A 70" PROJECTION SCREEN TYPE PST-E J15 Sheet Title: 54" 145" AUDIOVISUAL ROOM ELEVATIONS J11(N3,P4) 70" J14 Division of State Facilities J14 State of Wisconsin PROJECTION SCREEN TYPE PST-C New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin FPD-A Department of Administration 84" Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 3/ 8/ 2012 ADDENDUM NO. 2 102" J9 78" 48" Graphic Scale 7 AV401 Elevation 72 Seat Classroom Typical 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV401 12' 123" 123" 211" 138" 138" RA Project No.:1266.A 6" PROJECTION SCREEN TYPE PST-C 34" 34" 6" J12 J11(N3,P4) J11(N3,P4) Consultant: PROJECTION SCREEN TYPE PST-J 66" 60" PROJECTION SCREEN TYPE PST-J 18" 64" 83" J15 J15 4 AV402 102" Elevation Conference Room 4308 North Wall 3/8" = 1'-0" 102" J9 78" 48" 1 Elevation 160 Seat Lecture Hall 1415 West Wall AV402 3/8" = 1'-0" 33" 54" 64" 22" 128" 143" 86" 128" 5 AV402 P3 J3 N2 State of Wisconsin 18" 48" Elevation Humanities Research Lab 4415 East Wall NTS 6" J15 PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-E 117" University of Wisconsin - Eau Claire J42 Division of State Facilities J11(N3,P4) Department of Administration FPD-D 117" J15 6" 102" EQ EQ 78" 48" J8 48" 64" 18" P3 6 AV402 J3 N2 Elevation Humanities Research Lab 4415 South Wall NTS 2 Elevation 72 Seat Classroom 1704 North Wall AV402 3/8" = 1'-0" Sheet Title: 102" AUDIOVISUAL ROOM ELEVATIONS J9 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin PROJECTION SCREEN TYPE PST-C Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 45" J42 48" 18" N2 P3 J6 Graphic Scale 18" 3 Elevation Conference Room 4308 West Wall AV402 3/8" = 1'-0" 7 AV402 Elevation Humanities Research Lab 4415 West Wall NTS PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY P3 J6 N2 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV402 12' 53" 66" 66" RA Project No.:1266.A 68" 99" N2 11" P3 J6 6" 115" 124" 103" J14 J14 J14 J14 3 AV403 J14 Consultant: Elevation Library/Film Viewing Studio 4612 North Wall 3/8" = 1'-0" PROJECTION SCREEN TYPE PST-M 83" 83" J8 53" 41" 103" 124" J14 J14 90" 2 Elevation Library/Film Viewing Studio 4612 South Wall AV403 3/8" = 1'-0" 46" 40" 143" 128" 72" 127" 22" 93" 35" 80" 87" 72" 6" State of Wisconsin 6" 6" PROJECTION SCREEN TYPE PST-E J15 J12 PROJECTION SCREEN TYPE PST-E J15 PROJECTION SCREEN TYPE PST-E J14 J14 J12 90" J9 J9 102" 48" 66" 48" 5 Elevation 72 Seat Classroom 1804 North Wall AV403 3/8" = 1'-0" 6 AV403 143" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 18" Elevation 45 Seat Classroom 1916 West wall 3/8" = 1'-0" 174" 18" PROJECTION SCREEN TYPE PST-M 66" 66" 144" 107" EQ EQ J14 J14 EQ EQ EQ EQ J14 FPD-B J11(N3,P4) J11(N3,P4) FPD-B Sheet Title: P3 AUDIOVISUAL ROOM ELEVATIONS N2 66" 102" 102" 96" 66" J2 University of Wisconsin - Eau Claire 14" Elevation Library/Film Viewing Studio 4612 West Wall 3/8" = 1'-0" Division of State Facilities 4 AV403 Department of Administration 1 Elevation Library/Film Viewing Studio 4612 East Wall AV403 3/8" = 1'-0" Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 J12 90" 72" P3 J6 N2 102" 18" Graphic Scale 7 Elevation 45 Seat Classroom 1916 South Wall AV403 3/8" = 1'-0" 8 Elevation 72 Seat Classroom 1804 South Wall AV403 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV403 12' RA Project No.:1266.A 116" 116" 12" PROJECTION SCREEN TYPE PST-C Consultant: 10" 87" J8 J42 48" 58" 41" N2 1 Elevation Conference Room 4705 East Wall AV404 3/8" = 1'-0" P3 J6 11" 2 Elevation Conference Room 4705 North Wall AV404 3/8" = 1'-0" 160" 58" 58" 159" FPD-A 121" FPD-A J11(N3,P4) 111" FPD-A J11(N3,P4) J11(N3,P4) FPD-A FPD-A J11(N3,P4) J11(N3,P4) 73" 54" J3 N2 P2 P2 J3 N2 J3 N2 P2 54" P2 18" 3 Elevation Active Learning Classroom 1917 East Wall AV404 3/8" = 1'-0" J3 N2 P2 J3 N2 University of Wisconsin - Eau Claire 121" State of Wisconsin 111" Division of State Facilities PROJECTION SCREEN TYPE PST-D Department of Administration 6" 18" 60" 158" 6" PROJECTION SCREEN TYPE PST-D 156" 120" 121" 156" Sheet Title: 60" AUDIOVISUAL ROOM ELEVATIONS 158" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 4 Elevation Active Learning Classroom 1917 North Wall AV404 3/8" = 1'-0" Revisions: FPD-A FPD-A FPD-A J11(N3,P4) FPD-A No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS FPD-A J11(N3,P4) J9 J11(N3,P4) J11(N3,P4) J11(N3,P4) 30" 30" 30" 73" 30" 54" 18" 5 Elevation Active Learning Classroom 1917 West Wall AV404 3/8" = 1'-0" P2 J3 N2 30" P2 J3 30" N2 30" P2 30" J3 48" 54" N2 P3 18" P2 J3 N2 18" P2 J3 N2 6 Elevation Active Learning Classroom 1917 South Wall AV404 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY J2 N2 18" Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV404 12' 151" 151" 66" FPD-E RA Project No.:1266.A 151" 73" FPD-E J11(N3,P4) FPD-B J11(N3,P4) J11(N3,P4) J16 66" Consultant: 48" 54" 30" P2 1 Elevation Math Lab 2208 East Wall AV405 3/8" = 1'-0" 2 AV405 J4 N2 18" Elevation Meeting Room 2415 West Wall 3/8" = 1'-0" 16" 249" 130" 142" 143" 249" 6" J9 66" 57" 48" 4 AV405 Elevation 60 Seat Classroom 1920 West Wall 3/8" = 1'-0" 7" 76" 85" 144" 85" 111" 76" 6" J15 119" 6" PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-E J15 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 3 Elevation 45 Seat Classroom 2420 South Wall AV405 3/8" = 1'-0" Sheet Title: 48" AUDIOVISUAL ROOM ELEVATIONS J8 State of Wisconsin PROJECTION SCREEN TYPE PST-C University of Wisconsin - Eau Claire PROJECTION SCREEN TYPE PST-E Division of State Facilities PROJECTION SCREEN TYPE PST-E Department of Administration 6" Revisions: 102" 8" No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS J8 J9 66" 66" 48" 48" Graphic Scale 5 Elevation 100 Seat Classroom 2614 West Wall AV405 3/8" = 1'-0" 6 Elevation 45 Seat Classroom 1924 West Wall AV405 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV405 12' RA Project No.:1266.A 141" 21" 162" 192" 6" 36" 36" 36" Consultant: FPD-B PROJECTION SCREEN TYPE PST-E FPD-B J11(N3,P4) PROJECTION SCREEN TYPE PST-E J12 J11(N3,P4) J9 102" 54" 48" 1 Elevation 60 Seat Classroom 2304 North Wall AV406 3/8" = 1'-0" 2 Elevation 60 Seat Classroom 2804 South Wall AV406 3/8" = 1'-0" 169" 170" 186" 6" PROJECTION SCREEN TYPE PST-E J12 PROJECTION SCREEN TYPE PST-E J9 6" PROJECTION SCREEN TYPE PST-E J12 PROJECTION SCREEN TYPE PST-E 66" 90" 54" State of Wisconsin 6" University of Wisconsin - Eau Claire 84" 4 Elevation 60 Seat Classroom 2920 West Wall AV406 3/8" = 1'-0" 147" 142" 142" 20" 185" 168" 132" 131" 6" 6" 20" Sheet Title: 3 Elevation 60 Seat Classroom 2804 North Wall AV406 3/8" = 1'-0" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 48" AUDIOVISUAL ROOM ELEVATIONS 84" Division of State Facilities 168" Department of Administration 138" 24" 144" Revisions: PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-C PROJECTION SCREEN TYPE PST-E J9 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 J8 66" 48" 54" 63" N2 J6 P3 48" 18" Graphic Scale 5 Elevation 45 Seat Classroom 2924 West Wall AV406 3/8" = 1'-0" 6 Elevation 60 Seat Classroom 2704 North Wall AV406 3/8" = 1'-0" 7 AV406 Elevation Conference Room 2904 North Wall 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV406 12' 142" RA Project No.:1266.A 98" 123" Consultant: 11" 36" 36" 96" PROJECTION SCREEN TYPE PST-E PROJECTION SCREEN TYPE PST-E 102" 61" J9 48" 2 Elevation 60 Seat Classroom 2931 East Wall AV407 3/8" = 1'-0" 117" 78" State of Wisconsin 6" FPD-B PROJECTION SCREEN TYPE PST-C J11(N3,P4) 60" J5 J42 J8 18" 48" 3 AV407 4 Elevation Meeting Room 3027 West Wall AV407 3/8" = 1'-0" Elevation Meeting Room 3027 South Wall 3/8" = 1'-0" 5 AV407 18" 57" 6 AV407 Elevation Conference Room 3115B North Wall 3/8" = 1'-0" 160" 110" 242" 6" P3 J6 Elevation Seminar Room 3502 North Wall 3/8" = 1'-0" 191" 50" N2 83" 108" 110" PROJECTION SCREEN TYPE PST-E 12" J12 PROJECTION SCREEN TYPE PST-C 8" Sheet Title: N2 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin P3 University of Wisconsin - Eau Claire 102" AUDIOVISUAL ROOM ELEVATIONS 15" Division of State Facilities Elevation 45 Seat Classroom 2916 North Wall 3/8" = 1'-0" Department of Administration 1 AV407 Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 J12 PROJECTION SCREEN TYPE PST-C 33" J9 90" J8 J8 57" 41" J4 P3 N2 7 AV407 48" 58" 48" 66" 11" Elevation Center/Institute for Educational Leadership 3314 East Wall 3/8" = 1'-0" Graphic Scale 8 Elevation Seminar Room 3502 South Wall AV407 3/8" = 1'-0" 9 AV407 Elevation 45 Seat Classroom 2916 South Wall 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV407 12' 53" J16 136" 52" J11(N3,P4) J11(N3,P4) PROJECTION SCREEN TYPE FPD-E PROJECTION SCREEN TYPE FPD-E J16 67" 99" 52" J16 122" 52" 119" J11(N3,P4) J11(N3,P4) PROJECTION SCREEN TYPE FPD-E PROJECTION SCREEN TYPE FPD-E J16 RA Project No.:1266.A 65" Consultant: 66" 66" 48" 48" 30" P2 J4 N2 P2 18" J4 N2 J4 P2 1 Elevation Instructional Media Center 3315 East Wall AV408 3/8" = 1'-0" 2 AV408 P2 J4 N2 18" Elevation Instructional Media Center 3315 West Wall 3/8" = 1'-0" 141" 315" 30" N2 155" 178" 18" PROJECTION SCREEN TYPE PST-C 31" J11(N3,P4) 69" 31" 30" 56" 54" P2 J3 N2 J3 P2 N2 N2 3 Elevation Seminar Room 3504 East Wall AV408 3/8" = 1'-0" P3 J6 J3 P2 20" N2 4 Elevation Seminar Room 3504 North Wall AV408 3/8" = 1'-0" 14" PROJECTION SCREEN TYPE PST-C 55" 53" 76" 121" 130" 7" J12 FPD-A FPD-A J11(N3,P4) FPD-A J11(N3,P4) 81" 29" 72" 45" 30" J11(N3,P4) 31" Revisions: 31" 54" 54" 18" N2 5 Elevation Seminar Room 3504 South Wall AV408 3/8" = 1'-0" J3 P2 N2 J3 P2 N2 J3 New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 20" Sheet Title: 31" J11(N3,P4) University of Wisconsin - Eau Claire J11(N3,P4) FPD-A AUDIOVISUAL ROOM ELEVATIONS FPD-A Division of State Facilities FPD-A 63" Department of Administration 122" State of Wisconsin 129" P2 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 18" 6 Elevation Seminar Room 3504 West Wall AV408 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV408 12' 130" RA Project No.:1266.A 10" 138" 6" Consultant: PROJECTION SCREEN TYPE PST-E J8 48" 42" 1 Elevation Computer Classroom 3815 South Wall AV409 3/8" = 1'-0" 237" 237" 59" PROJECTION SCREEN TYPE PST-D 120" 118" 177" FPD-A FPD-A J9 FPD-A J11(N3,P4) J11(N3,P4) 30" 30" 30" 30" 30" 54" 18" N2 J3 P2 N2 J3 54" 56" 50" 54" J11(N3,P4) 75" 54" N2 P2 18" J3 20" N2 J3 N2 P2 J3 P2 18" P2 18" 2 Elevation Active Learning Classroom 3814 East Wall AV409 3/8" = 1'-0" 3 Elevation Active Learning Classroom 3814 North Wall AV409 3/8" = 1'-0" 230" 40" 132" 59" 6" PROJECTION SCREEN TYPE PST-D 108" 120" 120" 181" Sheet Title: J11(N3,P4) J11(N3,P4) FPD-A New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin FPD-A University of Wisconsin - Eau Claire 108" AUDIOVISUAL ROOM ELEVATIONS 120" Division of State Facilities 120" Department of Administration 181" State of Wisconsin 6" Revisions: J12 FPD-A FPD-A J11(N3,P4) FPD-A FPD-A J11(N3,P4) J11(N3,P4) 73" No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS J11(N3,P4) 72" 34" 56" 54" N2 J3 P2 18" 20" N2 J3 P2 N2 J3 P2 N2 J3 P2 Graphic Scale 4 Elevation Active Learning Classroom 3814 South Wall AV409 3/8" = 1'-0" 5 Elevation Active Learning Classroom 3814 West Wall AV409 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV409 12' 128" 174" RA Project No.:1266.A 6" PROJECTION SCREEN TYPE PST-D 50" 39" FPD-A FPD-A 326" FPD-A FPD-A Consultant: J11(N3,P4) J11(N3,P4) 66" 54" P2 J3 N2 J11(N3,P4) 73" 120" J3 P2 18" J11(N3,P4) 54" N2 116" 54" J3 18" N2 P2 P2 1 Elevation Active Learning Classroom 2917 East Wall AV410 3/8" = 1'-0" 2 AV410 126" 279" 114" 116" J3 N2 18" Elevation Active Learning Classroom 2917 North Wall 3/8" = 1'-0" 37" 6" PROJECTION SCREEN TYPE PST-D 133" 3 AV410 N2 30" J3 P2 30" 54" P2 N2 J3 N2 48" J11(N3,P4) 60" 18" N2 P3 J6 18" Elevation Active Learning Classroom 2917 South Wal 3/8" = 1'-0" Elevation Conference Room 3914 West Wall 3/8" = 1'-0" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 4 AV410 215" 6" PROJECTION SCREEN TYPE PST-D 30" 30" 30" FPD-A 30" 30" FPD-A J11(N3,P4) FPD-A 73" J11(N3,P4) FPD-A J11(N3,P4) 30" 121" P2 J3 N2 J11(N3,P4) P2 J3 N2 121" P2 J3 N2 Revisions: 54" 30" 119" 94" P2 J3 University of Wisconsin - Eau Claire J3 P2 30" J12 Sheet Title: 32" J11(N3,P4) J60 AUDIOVISUAL ROOM ELEVATIONS 28" J11(N3,P4) J11(N3,P4) FPD-B Division of State Facilities J11(N3,P4) FPD-B FPD-A 130" Department of Administration FPD-A 38" State of Wisconsin FPD-A 38" No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS N2 18" 5 Elevation Active Learning Classroom 2917 West Wall AV410 3/8" = 1'-0" Graphic Scale PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV410 12' 82" 83" 120" RA Project No.:1266.A 36" 59" 6" 153" 37" 36" 160" PROJECTION SCREEN TYPE PST-E J12 FPD-B FPD-B J11(N3,P4) Consultant: J11(N3,P4) J11(N3,P4) 96" J12 J8 FPD-E 66" 65" 54" 48" 30" 1 Elevation Special Education Methods 3916 North Wall AV411 3/8" = 1'-0" 2 Elevation Special Education Methods 3916 South Wall AV411 3/8" = 1'-0" 118" 45" 90" 114" State of Wisconsin PROJECTION SCREEN TYPE PST-E J12 FPD-E FPD-E J11(N3,P4) J11(N3,P4) 96" J8 66" University of Wisconsin - Eau Claire 85" 66" 66" 49" 4 Elevation Math Methods 3920 South Wall AV411 3/8" = 1'-0" 115" 46" 90" 116" 6" 194" 89" 100" PROJECTION SCREEN TYPE PST-E Sheet Title: 3 Elevation Math Methods 3920 North Wall AV411 3/8" = 1'-0" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 30" AUDIOVISUAL ROOM ELEVATIONS 90" Division of State Facilities 192" Department of Administration 6" Revisions: J12 No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS FPD-E FPD-E J11(N3,P4) J11(N3,P4) 96" J8 66" 66" 66" 48" 30" 30" Graphic Scale 5 Elevation Education Methods 3924 North Wall AV411 3/8" = 1'-0" 6 Elevation Education Methods 3924 South Wall AV411 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV411 12' RA Project No.:1266.A 191" 162" 6" PROJECTION SCREEN TYPE PST-C 19" Consultant: J8 J12 69" 48" J9 72" 64" 48" 18" 1 AV412 P3 J6 2 Elevation Language Lab 4712 West Wall AV412 3/8" = 1'-0" Elevation Library/Research Center 4301 East Wall 3/8" = 1'-0" 154" N2 157" 184" 206" 6" J42 64" 48" N2 P3 J4 64" 18" 81" 0" 5 Elevation Language Lab 4712 South Wall AV412 3/8" = 1'-0" 128" 212" 129" 73" 6" PROJECTION SCREEN TYPE PST-J PROJECTION SCREEN TYPE PST-J J15 J15 Sheet Title: 4 Elevation Library/Research Center 4301 South Wall AV412 3/8" = 1'-0" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 3 Elevation Library/Research Center 4301 North Wall AV412 3/8" = 1'-0" University of Wisconsin - Eau Claire State of Wisconsin 123" AUDIOVISUAL ROOM ELEVATIONS PROJECTION SCREEN TYPE PST-C Division of State Facilities PROJECTION SCREEN TYPE PST-C Department of Administration 6" Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 10/ 17/ 2012 CB 1034 102" 102" J9 48" 54" Graphic Scale 6 Elevation 140 Seat Lecture Hall 1614 West Wall AV412 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV412 12' 43" 120" 118" RA Project No.:1266.A 73" 118" 6" PROJECTION SCREEN TYPE PST-E J11(N3,P4) J11(N3,P4) J11(N3,P4) 66" FPD-E Consultant: 60" FPD-E FPD-E J8 66" 66" 48" 30" 30" 30" 1 Elevation Science Methods 3931 South Wall AV413 NTS FPD-A J11(N3,P4) FPD-E 26" 26" 26" 54" 4 AV413 J3 N2 P2 J3 N2 P2 Elevation Technology Lab 3406 East Wall NTS 20" J12 FPD-D J11(N3,P4) N2 18" Revisions: J16 54" J3 Sheet Title: 3 Elevation Science Methods 3931 East Wall AV413 NTS 44" 26" J11(N3,P4) New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin P2 18" J11(N3,P4) 66" 30" 33" 26" FPD-A University of Wisconsin - Eau Claire FPD-A 113" AUDIOVISUAL ROOM ELEVATIONS J11(N3,P4) 113" Division of State Facilities 221" State of Wisconsin 45" Department of Administration 2 Elevation Science Methods 3931 West Wall AV413 NTS No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 2/ 5/ 2013 CB 1060 48" J3 18" 5 Elevation Group Study Room Typical AV413 NTS Graphic Scale PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV413 12' 96" 96" 143" 6" PROJECTION SCREEN TYPE PST-E 126" 126" PROJECTION SCREEN TYPE PST-E J11(N3,P4) J11(N3,P4) 65" N2 J6 P3 N2 3 AV414 Elevation 60 Seat Classroom 2927 East Wall 3/8" = 1'-0" J3 P2 123" 25" 34" J9 54" N2 18" P2 J3 54" N2 18" J3 P2 48" 18" Elevation 60 Seat Classroom 2927 North Wall 3/8" = 1'-0" 75" 9" Consultant: J11(N3,P4) 54" 18" 1 AV414 84" RA Project No.:1266.A 66" 129" 129" 98" 35" 34" J12 J11(N3,P4) J11(N3,P4) P2 N2 18" P2 J3 N2 4 AV414 105" P2 18" Elevation 60 Seat Classroom 2927 West Wall 3/8" = 1'-0" 61" J3 144" N2 18" P2 J3 N2 18" J3 P2 18" Elevation 60 Seat Classroom 2927 South Wall 3/8" = 1'-0" 164" University of Wisconsin - Eau Claire 2 AV414 J3 54" State of Wisconsin N2 54" 54" 6" 181" 120" J9 120" J11(N3,P4) 113" J11(N3,P4) J11(N3,P4) 66" 48" 54" P2 5 AV414 7 AV414 Elevation 60 Seat Classroom 3714 North Wall 3/8" = 1'-0" J3 N2 54" P2 18" J3 N2 54" P2 18" J3 N2 18" Elevation 60 Seat Classroom 3714 East Wall 3/8" = 1'-0" Sheet Title: PROJECTION SCREEN TYPE PST-E New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin PROJECTION SCREEN TYPE PST-E AUDIOVISUAL ROOM ELEVATIONS 54" 54" Division of State Facilities J11(N3,P4) 96" J11(N3,P4) Department of Administration J11(N3,P4) Revisions: 10" 111" No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 65" 109" 46" 120" 120" 181" J12 96" J11(N3,P4) J11(N3,P4) J11(N3,P4) 54" 54" N2 6 AV414 Elevation 60 Seat Classroom 3714 South Wall 3/8" = 1'-0" J3 J11(N3,P4) N2 P2 18" 8 AV414 J3 P2 18" Graphic Scale 54" N2 J3 P2 18" 54" N2 J3 P2 18" Elevation 60 Seat Classroom 3714 West Wall 3/8" = 1'-0" PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV414 12' MOUNTING WITH DRYWALL CEILING POWER 1" OR 1-1/4" AV OR TELECOM 3/8 DIA. LAG BOLTS INTO BLOCKING. [J12] J-BOX SHOW WITH 3/8" THREADED ROD. OTHER MOUNTING HARDWARE OPTIONS ARE FEASIBLE. 16"W x 18"H x 3/4"THK PLYWOOD OR METAL BACKING 7" 10-1/2" 8" TRIM FLANGE 8-9/16" WOOD OR METAL STUDS ELECTRICAL CONNECTION TO INTERNAL SPLICE BOX ON LEFT END OF CASE. 7/8" KNOCKOUT FOR 1/2" CONDUIT. 12-1/2" 7-9/16" 6" MOUNTING WITH SUSPENDED CEILING (12) 1" & 1-1/4" CONDUIT KNOCKOUTS 7" 3/8" DIA. THREADED ROD OR OTHER. 3 7/16" RA Project No.:1266.A DRYWALL CEILING 6 5/8" AUDIENCE 1. BACKING AND J-BOX FOR WALL MOUNTED VIDEO CAMERA. 2. SEE PARTITION TYPES FOR STUD SIZE AND GAUGE. 3. VERIFY LOCATIONS OF BACKING PLATES WITH PLANS & ROOM ELEVATIONS. 4. FASTEN PLYWOOD OR METAL BACKING FLUSH WITH FACE OF STUDS. 5. ALWAYS SPAN BETWEEN TWO STUDS. 6. CAMERA AND MOUNTING BRACKETS BY AV CONTRACTOR. CEILING TILE 2 AV501 8" 8" TRIM FLANGE FSR FL-500P -6 1" OR 1-1/4" AUDIOVISUAL 4 AV501 DETAIL - WALL MOUNTED CAMERA BACKING NTS Consultant: DETAIL - FSR FL-500P-6 NTS 9" ELECTRICAL CONNECTION ON TOP OF LEFT END. POWER AV DATA POWER MOUNTING FLANGE CASE WIDTH (CW) 7" 17" [J14] OR [J15] J-BOX 8" 16"W x 18"H x 3/4"THK PLYWOOD OR METAL BACKING IMAGE SURFACE MOTORIZED PROJECTION SCREEN IMAGE SURFACE: HI-DEF GREY SEE SHEET AV002 FOR SIZES DATA POWER POWER AV 1. BACKING AND J-BOX FOR WALL MOUNTED LOUDPSEAKER. 2. SEE PARTITION TYPES FOR STUD SIZE AND GAUGE. 3. VERIFY LOCATIONS OF BACKING PLATES WITH PLANS & ROOM ELEVATIONS. 4. FASTEN PLYWOOD OR METAL BACKING FLUSH WITH FACE OF STUDS. 5. ALWAYS SPAN BETWEEN TWO STUDS. 6. LOUDSPEAKERS AND MOUNTING BRACKETS BY AV CONTRACTOR. PJX TYPE-C,D,E,&M DRAPER ACCESS SERIES-V MOTORIZED PROJECTION SCREEN 1 MOTORIZED PROJECTION SCREEN AV501 NTS 3 AV501 DETAIL - WALL MOUNTED SINGLE LOUDSPEAKER BOX NTS NEW WORK INSTALLATION WALL OPENING: 11" x 5-1/4" AV COMPARTMENT TOP AND/OR BOTTOM UPPER LOW-VOLTAGE ENTRY BOX NO.1 FOR AUDIOVISUAL CONNECTIONS SHIPPED STANDARD WITH ASSEMBLY (2 - #6-32 x 1/4" PAN HEAD SCREWS) POWER RECEPTACLE & NETWORK OUTLET WOOD OR METAL STUDS 3/4" PLYWOOD OR 16 GUAGE STEEL BACKING SECTIONS SPAN AT LEAST 3 STUDS (2) STUD BRACKET (2 - #6-32 x 1/4" PAN HEAD SCREWS) 16" STUD CENTERS STUD MOUNTING HARDWARE BY CUSTOMER (#6 SCREW, 1/2"x1" STAPLE, OR NAIL) FSR PWB-100 J11 ASSEMBLY [P4] AC OUTLET BOX (4 - #6-32 x 1/4" PAN HEAD SCREWS) [J11] ASSEMBLY STUD LOWER LOW-VOLTAGE ENTRY BOX N0.2 FOR AUDIOVISUAL CONNECTIONS - NOT SHOWN (MUST BE ORDERED SEPARATELY) FSR PWB-100 ASSY. Revisions: STUDS AND PLYWOOD BACKING BY G.C. No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS 1 5/ 31/ 2012 RFI 24 RESPONSE [N3] NETWORK OUTLET BOX NOT SHOWN (MUST BE ORDERED SEPARATELY) CUTOUT AND FSR ASSEMBLY BY E.C. 1. BACKING AND J-BOX FOR WALL MOUNTED FLATPANEL DISPLAY 2. BACKING MUST BE MIN 32"W AND 24"H WITH J-BOX CENTERED AT LOCATION 3. ALWAYS SPAN BETWEEN THREE STUDS. 4. SEE PARTITION TYPES FOR STUD SIZE AND GAUGE. 5. VERIFY LOCATIONS OF BACKING PLATES WITH PLANS & ROOM ELEVATIONS. 6. FASTEN PLYWOOD OR METAL BACKING FLUSH WITH FACE OF STUDS. 7. FLAT PANEL DISPLAYS AND MOUNTING BRACKETS BY AV CONTRACTOR. 6 DETAIL - FSR PWB-100 BACKING AV501 NTS University of Wisconsin - Eau Claire BOTTOM OPTIONS: PROVIDE QTY(1)#175CHA BOTTOM HOUSING ASSEMBLY AND QTY(1)#5BLH BOTTOM HOUSING ASSEMBLY FOR THE OUTSIDE POWER COMPARTMENTS (TUNNELS BETWEEN COMPARTMENTS). PROVIDE QTY(1)# 22CHA BOTTOM HOUSING ASSEMBLY (OR) PROVIDE QTY(2)#1125CHA 1-1/4" CONDUIT RECEIVER BOTTOM HOUSING ASSEMBLYS FOR THE RIGHT AND CENTER MIDDLE (AV) COMPARTMENT AS REQUIRED PER ROOM. PROVIDE QTY1#1125CHA 1-1/4" CONDUIT RECEIVER FOR THE LEFT MIDDLE (DATA) COMPARTMENT. COVER OPTIONS: VERIFY COVER STYLE AND FINISH WITH ARCHITECT PRIOR TO INSTALLATION. 5 DETAIL - EVOLUTION 8AT 8" POKE-THRU AV501 NTS Sheet Title: MASKING BORDER AUDIOVISUAL DETAILS FB9 POKE-THRU WIREMOLD (LEGRAND) EVOLUTION 8AT 8" POKE THROUGH DEVICE. INTERIOR OPTIONS: PROVIDE QTY(2)#68REC INSERT PLATES FOR OUTSIDE (POWER) COMPARTMENTS. PROVIDE QTY(2) #8B INSERT PLATES FOR THE RIGHT AND CENTER MIDDLE COMPARTMENT, RESERVING THIS COMPARTMENT FOR AUDIOVISUAL USE. PROVIDE QTY1#8ACT6A DEVICE MOUNTING PLATE FOR THE LEFT MIDDLE (DATA) COMPARTMENT. Division of State Facilities WOOD OR METAL STUDS Department of Administration TAB TENSIONING SYSTEM AV State of Wisconsin 8 11/16" 7 1/8" New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin 6 5/8" COVER CENTER SECTION (2 - #6-32 x 1/2" UNDERCUT FLAT HEAD SCREWS) COVER (4 PAINTED #6-32 x 3/4" OVAL HEAD SCREWS) 7 AV501 MOUNTING HOLES FOR 1/2" DRYWALL DIRECT-TO-STUD MOUNTING HOLES MOUNTING HOLES FOR 5/8" DRYWALL 1/2" - 5/8" WALL THICKNESS DETAIL - FSR PWB-100 BOX NTS PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY Graphic Scale 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV501 12' SIDE ELEVATION 1/2" MACHINE-THREAD SHIELDS AND BOLTS TO SECURE UNISTRUT TO UNDERSIDE OF DECK BY G.C. (8 PLACES MIN) PLAN VIEW !!! CRITICAL DISTANCE D1 !!! SEE PROJECTION SCHEDULE SHEET AV002 UNISTRUT ASSEMBLY VIEW FROM ABOVE HARD DECK CABLING PASS-THRU PULLBOXES FOR POWER, AV AND NETWORK -TYPICAL- UNISTRUT P-1000 SERIES CHANNEL 6FT. LENGTH (MIN) TWO PLACES BY G.C. 3/8" THREADED ROD BY G.C. LENGTH AS REQ'D. (4 PLACES MIN) UNISTRUT P-1000 SERIES CHANNEL 4FT. LENGTH (MIN) TWO PLACES BY G.C. CHIEF MANUFACTURING CMA-110 DISPLAY DECKPLATE BY G.C. UNISTRUT P-1000 SERIES SLOTTED CHANNEL 4FT. LENGTH (MIN) TWO PLACES BY G.C. 1/2" MACHINE-THREAD SHIELDS & BOLTS SECURE UNISTRUT TO UNDERSIDE OF DECK BY G.C. (8 PLACES MIN.) FLEXIBLE CONDUIT BY E.C. LENGTH AS REQUIRED TO ACCOMMODATE MOVEMENT OF J12 WITHIN FOOTPRINT OF UNISTRUT GRID 1 1/2" SCHED. 40 THREADED PIPE BY G.C. J40(N31,P30) NIGEL B DISPLAY JUNCTION BOX (SEE 2/AV502) NETWORK OUTLET, POWER RECEPTACLE BY E.C PROVISIONS BELOW THIS ELEVATION BY AV CONTRACTOR 1 1/2" SCHED. 40 THREADED PIPE BY AV CONTRACTOR ESCUTCHEON BY AV CONTRACTOR [N31] NETWORK OUTLET BOX FLEXIBLE CONDUIT APDTR FOR AC POWER TOP VIEW WITH COVER REMOVED Consultant: [N30] NETWORK PULL BOX N31 PROJECTION SCREEN CENTERLINE [P8] POWER PULL BOX P30 SECURE WITH DOUBLE LOCKING NUT BY G.C. (TYP FOR ALL) WORKBOX W/AC POWER RECEPTACLE (INCLUDED) RECEIVER TOP & BOTTOM FOR 1-1/2" THREADED PIPE NB-PEBPM PLENUM EQUIPMENT BOX W/POLE MOUNT BY NIGEL-B DESIGN SCREEN CABLE PASS-THRU TO SUPPORT PIPE FLEXIBLE CONDUIT BY E.C. LENGTH REQUIRED TO ACCOMODATE MOVEMENT OF [J40] WITHIN FOOTPRINT OF UNISTRUT GRID [J40] DISPLAY JUNCTION BOX BELOW AND ATTACHED TO PIPE BY E.C. ALSO SEE 2/AV502 FRONT VIEW WITH COVER REMOVED UNISTRUT P-1000 SERIES SLOTTED CHANNEL 8FT. LENGTH (MIN) TWO PLACES BY G.C. REMOVABLE COVER ADJUSTABLE SIDE SIDE BACK CABLE PASS-THRU & THREADED PIPE RECEIVER HOUSING CEILING 2 DETAIL - NEIGEL B AV502 NTS USE SUPPORT AND ANCHORING SYSTEMS APPROPRIATE FOR STRUCTURAL CONDITIONS. PROVIDE A SUPPORT SYSTEM ADEQUATE FOR A GROSS WEIGHT OF 30 LBS PLUS A SAFETY FACTOR OF AT LEAST FIVE. AIRCRAFT CABLE OR THREADED ROD VIEW FROM SIDE HARD DECK NETWORK (J41) & AV (N30) PULL BOXES SINGLE-GANG ELECTRICAL WORKBOX (P31) W/DUPLEX RECEPTACLE (DOWNWARD FACING) R 8 1/2" ADJUSTABLE IN THIS RADIUS CHIEF CMS-445 SPEED-CONNECT SUSPENDED CEILING PLATE ESCUTCHEON BY AV CONTRACTOR 23 5/8" 23 5/8" 94.5 GENERAL CONTRACTOR TO PROVIDE ALL ELEMENTS SHOWN, EXCEPTING THE ADJUSTABLE SUPPORT PIPE AND ESCUTCHEON RING. LAY-IN CEILING 1-1/2" NPT THREADED PIPE BY AV CONTRACTOR 4 X 1 1/8" !!! D1 - CRITICAL DISTANCE !!! SEE PROJECTION SCHEDULE SHEET AV002 3 DETAIL - CMS445-W CEILING TILE MOUNT AV502 NTS 4 DETAIL - PROJECTOR CHEIF CMA 470 AV502 NTS New Education Building University of Wisconsin-Eau Claire Eau Claire, Wisconsin AV AND NETWORK CABLE BUNDLE RUN DOWN INSIDE SUPPORT PIPE Sheet Title: 1.5" NPSM THREADS University of Wisconsin - Eau Claire POWER PULL BOX (P8) AUDIOVISUAL DETAILS 1" FLEX CONDUIT (36" LEGNTH MIN) AV & DATA EMT CONDUITS PER ROOM CONDUIT RISER DIAGRAMS Division of State Facilities HARD DECK Department of Administration 1 DETAIL - UNISTRUT WITH NIEGEL B AV502 NTS State of Wisconsin CONDUIT BY E.C. HARD DECK RA Project No.:1266.A METHOD FOR INSTALLING CEILING MOUNTED DISPLAY TO UNDERSIDE OF DECK (TYP) Revisions: No. Date: Description: BD 2/ 3/ 2012 BI D DRAWI NGS Graphic Scale PROVIDED TO AV CONTRACTOR FOR REFERENCE PURPOSES ONLY 0' 2' 4' 8' DSF Number 08A1Z Set Type CD Date Issued 04/27/2012 Sheet Number AV502 12'