Avaya S9rm Uninterruptible Power Systems Site Preparation

   EMBED


Share

Transcript

Avaya S9RM Uninterruptible Power Systems Site Preparation, Installation and Operator’s Manual www.powerware.com/avaya Avaya S9RM Uninterruptible Power Systems Site Preparation, Installation and Operator’s Manual www.powerware.com/avaya US Patent 6,160,722 Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: S Harmonized Standards: EN 62040-1-1 and EN 50091-2; IEC 60950-1 S EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Eaton Power Quality Oy Koskelontie 13 FIN-02920 Espoo Finland Phone: +358-9-452 661 Fax: +358-9-452 665 68 Avaya and the Avaya logo are trademarks of Avaya Inc. and may be registered in certain jurisdictions. Powerware and ABM are registered trademarks and ConnectUPS is a trademark of Eaton Electrical Inc. HyperTerminal is a registered trademark of Hilgraeve. ECopyright 2001–2006 Avaya Inc. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Avaya Inc. Class B EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: S Reorient or relocate the receiving antenna. S Increase the separation between the equipment and the receiver. S Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. S Consult the dealer or an experienced radio/TV technician for help. ICES-003 This Class B Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES-003. Cet appareil numérique de la classe B respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada. VCCI Notice Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for additional information, such as important operating and maintenance instructions. RJ-45 RECEPTACLE - For 230V models only: this receptacle provides network interface connections. Do not plug telephone or telecommunications equipment into this receptacle. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly. For more information, contact your local recycling/reuse or hazardous waste center. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. Table of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Inspecting the Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the UPS Internal Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UPS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack-Mount Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tower Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote Emergency Power-off Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UPS Rear Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 19 20 21 22 25 27 29 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Turning the UPS On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starting the UPS on Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turning the UPS Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initiating the Self-Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Battery Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bypass Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standby Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 31 32 32 33 34 35 36 36 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing ERM Configurator with a ConnectUPS-X Web/SNMP Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Placing the Card into Serial Pass-Through Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exiting Serial Pass-Through Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 40 40 42 Additional UPS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 ConnectUPS-X Web/SNMP Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Alarm Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network Transient Protector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Load Segments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 44 46 47 4 5 6 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C i TABLE OF CONTENTS 7 UPS Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 UPS and Battery Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Storing the UPS and Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . When to Replace Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replacing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Replace Internal Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Replace Extended Battery Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Testing New Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recycling the Used Battery or UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 49 50 50 51 52 54 54 8 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Audible Alarms and UPS Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silencing an Audible Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Obtaining Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 59 62 ii Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 1 Introduction The Avayat S9RM uninterruptible power system (UPS) protects your sensitive electronic equipment from the most common power problems including power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variations, switching transients, and harmonic distortion. Power outages can occur when you least expect it and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work sessions, and damage hardware — causing hours of lost productivity and expensive repairs. With the Avaya S9RM, you can safely eliminate the effects of power disturbances and guard the integrity of your equipment. Figure 1 shows the Avaya S9RM UPS with an optional Extended Battery Module (EBM). Figure 1. The Avaya S9RM UPS with Optional EBM Providing outstanding performance and reliability, the Avaya S9RM’s unique benefits include the following: S Online UPS design with pure sine wave output. The UPS filters and regulates incoming AC power and provides consistent power to your equipment without draining the battery. S 2U rack height that conserves valuable rack space. S Two-in-one form factor for using the UPS in a rack-mount configuration or as a standalone cabinet. S ABM® technology that uses advanced battery management to increase battery service life, optimize recharge time, and provide a warning before the end of useful battery life. S Hours of extended runtime with up to four EBMs or with up to three Extended Battery Cabinets (EBC48s). Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 1 INTRODUCTION S Start-on-battery capability for powering up the UPS even if utility power is not available. S Hot-swappable batteries that simplify maintenance by allowing you to replace batteries safely without powering down the critical load. S Emergency shutdown control through the remote emergency power-off (REPO) port. S Network power management with the ConnectUPSt-X Web/SNMP Card, providing SNMP and HTTP capabilities, monitoring through a Web browser interface, and connection to a twisted-pair Ethernet (10/100BaseT) network. S Network transient protector that guards your network communications equipment from surges. Low voltage models can also protect modems, fax machines, or other telecommunications equipment. S Advanced power management with the Software Suite CD for graceful shutdowns and power monitoring. S Sequential shutdown and load management through separate receptacle groups, called load segments. S Backed by worldwide agency approvals. 2 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 2 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference. DANGER This UPS contains LETHAL VOLTAGES. All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the UPS. WARNING S This UPS contains its own energy source (batteries). The output receptacles may carry live voltage even when the UPS is not connected to an AC supply. S For 220–240V models, the output receptacles may remain electrically live. If the input power source in your application is wired line-to-neutral (as in most European applications), the voltage to the output receptacles is 0V. With line-to-line input wiring, the voltage to the output receptacles is 110–120V (measured from line-to-ground or line-to-neutral, depending on the UPS wiring). S Do not remove or unplug the input cord when the UPS is turned on. This removes the safety ground from the UPS and the equipment connected to the UPS. S To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40°C (104°F). Do not operate near water or excessive humidity (95% maximum). S To comply with international standards and wiring regulations, the total equipment connected to the output of this UPS must not have an earth leakage current greater than 1.5 milliamperes. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 3 SAFETY WARNINGS CAUTION S Batteries can present a risk of electrical shock or burn from high short-circuit current. Observe proper precautions. Servicing should be performed by qualified service personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from batteries. S Proper disposal of batteries is required. Refer to your local codes for disposal requirements. S Never dispose of batteries in a fire. Batteries may explode when exposed to flame. Sikkerhedsanvisninger VIGTIGE SIKKERHEDSANVISNINGER GEM DISSE ANVISNINGER Denne manual indeholder vigtige instruktioner, som skal følges under installation og vedligeholdelse af UPS’en og batterierne. Læs venligst alle instruktioner inden betjening af udstyret og gem denne manual mhp. fremtidige opslag. FARE Denne UPS indeholder LIVSFARLIG HØJSPÆNDING. Alle reparationer og vedligeholdelse bør kun udføres af en AUTORISERET SERVICETEKNIKER. Ingen af UPS’ens indvendige dele kan repareres af brugeren. ADVARSEL! S Denne UPS indeholder sin egen energikilde (batterier). Udgangsstikkene kan endog være strømførende, når UPS’en ikke er koblet til en vekselstrømsforsyning. S På 220–240V-modeller kan udgangsstikkene være strømførende. Hvis ledningsføringen til indgangsstrømkilden på din enhed er fase-til-neutral (som på de fleste europæiske enheder), er spændingen til udgangsstikkene 0V. Med en fase-til-fase indgangsledningsføring er spændingen til udgangsstikkene 110–120V (målt fra fase-til-jord eller fase-til-neutral, afhængig af UPS-ledningsføringen). S Netledningen må ikke fjernes og stikket må ikke trækkes ud, mens UPS’en er tændt. Dette fjerner sikkerhedsjorden fra UPS’en og fra det udstyr, der er sat til. S Installér denne UPS i et temperatur- og fugtighedskontrolleret indendørsmiljø, frit for ledende forureningsstoffer for at formindske risikoen for brand og elektrisk stød. Rumtemperaturen må ikke overstige 40°C. UPS’en bør ikke betjenes nær vand eller høj fugtighed (maksimalt 95%). S I overensstemmelse med internationale normer og bestemmelser for el-installation må det udstyr, der er forbundet til udgangen af denne UPS, tilsammen ikke overskride en jordafdelingsspænding på mere end 1,5 milliampere. 4 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS ADVARSEL S Batterierne kan give risiko for elektrisk stød eller brandsår forårsaget af høj kortslutningsstrøm. Overhold gældende forsigtighedsregler. Servicering skal udføres af kvalificeret servicepersonale med kendskab til batterier og gældende forsigtighedsregler. Hold uautoriseret personale væk fra batterierne. S Korrekt bortskaffelse af batterier er påkrævet. Overhold gældende lokale regler for bortskaffelsesprocedurer. S Skaf dig aldrig af med batterierne ved at brænde dem. Batterierne kan eksplodere ved åben ild. Belangrijke Veiligheidsinstructies BELANGRIJKE VEILIGHEIDSINSTRUCTIES BEWAAR DEZE INSTRUCTIES Deze handleiding bevat belangrijke instructies die u dient te volgen tijdens de installatie en het onderhoud van de UPS en de accu’s. Lees alle instructies voordat u de apparatuur in bedrijf neemt en bewaar deze handleiding als naslagwerk. GEVAAR Deze UPS bevat LEVENSGEVAARLIJKE ELEKTRISCHE SPANNING. Alle reparaties en onderhoud dienen UITSLUITEND DOOR ERKEND SERVICEPERSONEEL te worden uitgevoerd. Er bevinden zich GEEN ONDERDELEN in de UPS die DOOR DE GEBRUIKER kunnen worden GEREPAREERD. WAARSCHUWING S Deze UPS bevat een eigen energiebron (batterijen). De uitgangscontactdoos kan onder spanning staan, zelfs wanneer de UPS niet is aangesloten op de netspanning. S Bij de modellen van 220–240V kan de uitgangscontactdoos onder spanning blijven staan. Als de bedrading van de ingangsspanningsbron in uw systeem loopt van fase naar aarde (zoals bij de meeste Europese systemen) dan bedraagt de spanning op de uitgangscontactdozen 0 V. Als de ingangsbedrading loopt van fase naar fase dan bedraagt de spanning op de uitgangscontactdozen 110–120V (gemeten tussen fase en aarde of tussen fase en neutraal, afhankelijk van de UPS-bedrading). S Verwijder de ingangsnoer niet of haal de stekker van de ingangsnoer er niet uit terwijl de UPS aan staat. Hierdoor zou de UPS en uw aangesloten apparatuur geen aardebeveiliging meer hebben. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 5 SAFETY WARNINGS S Teneinde de kans op brand of elektrische schok te verminderen dient deze UPS in een gebouw met temperatuur- en vochtigheidregeling te worden geïnstalleerd, waar geen geleidende verontreinigingen aanwezig zijn. De omgevingstemperatuur mag 40°C niet overschrijden. Niet gebruiken in de buurt van water of bij zeer hoge vochtigheid (max. 95%). S Om aan de internationale normen en bedradingsvoorschriften te voldoen mag de gehele apparatuur die op de uitgang van deze UPS is aangesloten, geen aardlekstroom van meer dan 1,5 milliampère hebben. OPGELET S Batterijen leveren gevaar op voor elektrische schokken en kunnen brandwonden veroorzaken door een grote kortsluitstroom. Neem de juiste voorzorgsmaatregelen in acht. Het onderhoud moet worden uitgevoerd door bevoegde onderhoudsmonteurs die verstand hebben van accu’s en op de hoogte zijn van de vereiste voorzorgsmaatregelen. Houd onbevoegden uit de buurt van de accu’s. S De batterijen moeten op de juiste wijze worden opgeruimd. Raadpleeg hiervoor uw plaatselijke voorschriften. S Nooit batterijen in het vuur gooien. De batterijen kunnen ontploffen. 6 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS Tarkeita Turvaohjeita TÄRKEITÄ TURVAOHJEITA - SUOMI SÄILYTÄ NÄMÄ OHJEET Tämä käyttöohje sisältää tärkeitä ohjeita, joita on noudatettava UPS-virtalähteen ja akkujen asennuksen ja huollon yhteydessä. Lue kaikki ohjeet ennen laitteiston käyttöä ja säilytä ohje myöhempää tarvetta varten. VAARA Tämä UPS sisältää HENGENVAARALLISIA JÄNNITTEITÄ. Kaikki korjaukset ja huollot on jätettävä VAIN VALTUUTETUN HUOLTOHENKILÖN TOIMEKSI. UPS ei sisällä MITÄÄN KÄYTTÄJÄN HUOLLETTAVIA OSIA. VAROITUS S Tässä UPS-virtalähteessä on oma energianlähde (akut). Lähtövastakkeissa voi olla jännite, vaikka UPS-virtalähdettä ei ole kytketty verkkovirtaan. S 220–240V -malleissa lähtövastakkeissa voi säilyä jännite. Jos sovelluksen tulovirtalähde on johdotettu linjasta neutraaliin (kuten useimmissa eurooppalaisissa sovelluksissa) lähtövastakkeiden jännite on 0 V. Linjasta linjaan –tulojohdotuksessa lähtövastakkeiden jännite on 110–120V (mitataan linjasta maahan tai linjasta neutraaliin, UPS-virtalähteen johdotuksesta riippuen). S Älä poista tai irrota sisääntulojohtoa, kun UPS on kytkettynä. Tämä poistaa turvamaadoituksen UPS-laitteesta ja siihen liitetystä laitteistosta. S Vähentääksesi tulipalon ja sähköiskun vaaraa asenna tämä UPS sisätiloihin, joissa lämpötila ja kosteus on säädettävissä ja joissa ei ole virtaa johtavia epäpuhtauksia. Ympäristön lämpötila ei saa ylittää 40 °C. Älä käytä lähellä vettä ja vältä kosteita tiloja (95 % maksimi). S Kansainväliset normit ja johdotusmääräykset vaativat, että kaikkien tämän UPS-laitteen ulostulokytkentöjen yhteinen maavuotovirta ei ylitä 1,5 milliampeeria (mA). VARO S Akut voivat aiheuttaa sähköiskun tai palovammojen vaaran johtuen suuresta oikosulkuvirrasta. Noudata kaikkia asianmukaisia varotoimia. Laitteen saa huoltaa vain ammattitaitoinen huoltohenkilökunta, joka tuntee akut ja niihin liittyvät varotoimet. Älä päästä valtuuttamatonta henkilöstöä lähelle akkuja. S Akusto täytyy hävittää säädösten mukaisella tavalla. Noudata paikallisia määräyksiä. S Älä koskaan heitä akkuja tuleen. Ne voivat räjähtää. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 7 SAFETY WARNINGS Consignes de sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS Ce manuel comporte des instructions importantes que vous êtes invité à suivre lors de toute procédure d’installation et de maintenance des batteries et de l’onduleur. Veuillez consulter entièrement ces instructions avant de faire fonctionner l’équipement et conserver ce manuel afin de pouvoir vous y reporter ultérieurement. DANGER! Cet onduleur contient des TENSIONS MORTELLES. Toute opération d’entretien et de réparation doit être EXCLUSIVEMENT CONFIÉE A UN PERSONNEL QUALIFIÉ AGRÉÉ. AUCUNE PIÈCE RÉPARABLE PAR L’UTILISATEUR ne se trouve dans l’onduleur. AVERTISSEMENT! S Cette onduleur possède sa propre source d’alimentation (batteries). Il est possible que les prises de sortie soient sous tension même lorsque l’onduleur n’est pas connectée à une alimentation CA. S En ce qui concerne les modèles 220–240 V, il est possible que les prises de sortie restent sous tension. Si la source d’alimentation de votre application est câblée phase et neutre (comme dans la majorité des applications européennes), la tension vers les prises de sortie est de 0 V. Avec un câblage d’entrée phase à phase, la tension vers les prises de sortie est de 110–120 V (mesurée entre phase et terre ou phase et neutre suivant le câblage de l’onduleur). S Ne pas retirer le cordon d’alimentation lorsque l’onduleur est sous tension sous peine de supprimer la mise à la terre de l’onduleur et du matériel connecté. S Pour réduire les risques d’incendie et de décharge électrique, installer l’onduleur uniquement à l’intérieur, dans un lieu dépourvu de matériaux conducteurs, où la température et l’humidité ambiantes sont contrôlées. La température ambiante ne doit pas dépasser 40 °C. Ne pas utiliser à proximité d’eau ou dans une atmosphère excessivement humide (95 % maximum). S Afin d’être conforme aux normes et règlements internationaux de câblage, le courant de fuite à la terre de la totalité du matériel branché sur la sortie de l’onduleur ne doit pas dépasser 1,5 mA. 8 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS ATTENTION! S Les batteries peuvent présenter un risque de choc électrique ou de brûlure provenant d’un courant de court-circuit haute intensité. Observez les précautions appropriées. L’entretien doit être réalisé par du personnel qualifié connaissant bien les batteries et les précautions nécessaires. N’autorisez aucun personnel non qualifié à manipuler les batteries. S Une mise au rebut réglementaire des batteries est obligatoire. Consulter les règlements en vigueur dans votre localité. S Ne jamais jeter les batteries au feu. L’exposition aux flammes risque de les faire exploser. Sicherheitswarnungen WICHTIGE SICHERHEITSANWEISUNGEN AUFBEWAREN Dieses Handbuch enthält wichtige Anweisungen, die Sie während der Installation und Wartung des USV (Unterbrechungsfreies Stromversorgungssystem) und der Batterien befolgen müssen. Bitte lesen Sie alle Anweisungen des Handbuches bevor sie mit dem Gerät arbeiten. Bewaren Sie das Handbuch zum Nachlesen auf. WARNUNG Die USV führt lebensgefährliche Spannungen. Alle Reparatur- und Wartungsarbeiten sollten nur von Kundendienstfachleuten durchgeführt werden. Die USV enthält keine vom Benutzer zu wartenden Komponenten. ACHTUNG S Dieses USV (Unterbrechungsfreies Stromversorgungssystem) enthält eine eigene Energiequelle (Batterien). Die Ausgangssteckdosen können Spannung führen, auch wenn das USV nicht an eine Wechselstromquelle angeschlossen ist. S Bei Modellen mit 220–240 Volt können die Ausgangssteckverbinder stromführend bleiben. Wenn die Eingangsstromquelle in Ihrer Anlage mit Masseleitung verkabelt ist (wie in den meisten europäischen Anlagen), beträgt die Spannung an den Ausgangssteckverbindern 0 Volt. Bei einer Verkabelung mit Außenleitern beträgt die Spannung an den Ausgangssteckverbindern 110–120 Volt (gemessen von Leitung zu Masse oder Leitung zu Masseleiter, abhängig von der USV-Verkabelung. S Das Eingangskabel nicht entfernen oder abziehen, während die USV eingeschaltet ist, weil hierdurch die Sicherheitserdung von der USV und den daran angeschlossenen Geräten entfernt wird. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 9 SAFETY WARNINGS S Um die Brand- oder Elektroschockgefahr zu verringern, diese USV nur in Gebäuden mit kontrollierter Temperatur und Luftfeuchtigkeit installieren, in denen keine leitenden Schmutzstoffen vorhanden sind. Die Umgebungstemperatur darf 40°C nicht übersteigen. Die USV nicht in der Nähe von Wasser oder in extrem hoher Luftfeuchtigkeit (max. 95 %) betreiben. S Um internationale Normen und Verdrahtungsvorschriften zu erfüllen, dürfen die an den Ausgang dieser USV angeschlossenen Geräte zusammen einen Erdableitstrom von insgesamt 1,5 Milliampere nicht überschreiten. VORSICHT! S Batterien können das Risiko eines elektrischen Schlags bergen oder durch hohen Kurzschlussstrom in Brand geraten. Die richtigen Vorsichtsmaßnahmen beachten. Die Wartung muss von qualifiziertem Wartungspersonal durchgeführt werden, das im Umgang mit Batterien geübt ist und über gute Kenntnisse der erforderlichen Vorsichtsmaßnahmen verfügt. Nicht autorisiertes Personal von Batterien fern halten. S Die Batterien müssen ordnungsgemäß entsorgt werden. Hierbei sind die örtlichen Bestimmungen zu beachten. S Batterien niemals verbrennen, da sie explodieren können. Avvisi di sicurezza IMPORTANTI ISTRUZIONI DI SICUREZZA CONSERVARE QUESTE ISTRUZIONI Il presente manuale contiene importanti istruzioni da seguire durante l’installazione e la manutenzione dell’UPS e delle batterie. Leggere integralmente le istruzioni prima di utilizzare l’apparecchiatura e conservare il presente manuale per futuro riferimento. PERICOLO La TENSIONE contenuta in questo gruppo statico di continuità è LETALE. Tutte le operazioni di riparazione e di manutenzione devono essere effettuate ESCLUSIVAMENTE DA PERSONALE TECNICO AUTORIZZATO. All’interno del gruppo statico di continuità NON vi sono PARTI RIPARABILI DALL’UTENTE. 10 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS AVVERTENZA S L’UPS contiene la propria fonte di energia (batterie). Le prese d’uscita possono essere sotto tensione anche quando l’UPS non è collegato all’alimentazione elettrica CA. S Nei modelli da 220–240 V è possibile che le prese d’uscita rimangano sotto tensione. Se la fonte di alimentazione in entrata dell’installazione è costituita da un collegamento linea-neutro (come accade nella maggior parte delle installazioni europee), la tensione delle prese d’uscita è pari a 0 V. Con un cablaggio in entrata del tipo linea-linea, la tensione sulle prese d’uscita è 110–120 V (con misurazione effettuata da linea a terra o da linea a neutro in base al cablaggio dell’UPS). S Non rimuovere nè scollegare il cavo di ingresso quando il gruppo statico di continuità è acceso poichè in tal modo si disattiverebbe il collegamento a terra di sicurezza del gruppo statico di continuità e dell’apparecchiatura ad esso collegata. S Per ridurre il rischio di incendio o di scossa elettrica, installare il gruppo statico di continuità in un ambiente interno a temperatura ed umidità controllata, privo di agenti contaminanti conduttivi. La temperatura ambiente non deve superare i 40°C. Non utilizzare l’unità in prossimità di acqua o in presenza di umidità eccessiva (95% max). S Per conformità con gli standard internazionali e con le norme in merito al cablaggio, tutta l’apparecchiatura collegata con l’uscita del gruppo statico di continuità non deve avere una corrente di dispersione di terra superiore a 1,5 milliampere. ATTENZIONE S Le batterie possono comportare un rischio di scossa elettrica o di ustione in seguito a un’elevata corrente di corto circuito. Osservare le dovute precauzioni. L’assistenza deve essere eseguita da personale qualificato esperto di batterie e delle necessarie precauzioni. Tenere il personale non autorizzato lontano dalle batterie. S Le batterie devono essere smaltite in modo corretto. Per i requisiti di smaltimento fare riferimento alle disposizioni locali. S Non gettare mai le batterie nel fuoco poichè potrebbero esplodere se esposte alle fiamme. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 11 SAFETY WARNINGS Viktig Sikkerhetsinformasion VIKTIGE SIKKERHETSINSTRUKSJONER GJEM DISSE INSTRUKSJONENE Denne håndboken inneholder viktige instruksjoner som du bør overholde ved montering og vedlikehold av UPS-enheten og batteriene. Les alle instruksjoner før utstyret tas i bruk, og gjem håndboken til fremtidig referanse. FARLIG Denne UPS’en inneholder LIVSFARLIGE SPENNINGER. All reparasjon og service må kun utføres av AUTORISERT SERVICEPERSONALE. BRUKERE KAN IKKE UTFØRE SERVICE PÅ NOEN AV DELENE i UPS’en. FARLIG S UPS-enheten inneholder sin egen energikilde (batterier). Utgangsstikkene kan være strømførende selv når UPS-enheten ikke er koblet til et strømuttak. S Utgangsstikkene kan være strømførende for 220–240V modellene. Spenningen til utgangsstikkene vil være 0 V dersom din enhets strømkilde er fase-til-nøytral (som på de fleste europeiske enheter). Med ledningsført fase-til-fase inngang vil spenningen til utgangsstikkene være 110–120V (målt fra fase-til-jord eller fase-til-nøytral, avhenging av UPS-ledningsføringen). S Strømforsyningskabelen må ikke fjernes eller trekkes ut når UPS’en er på, slik at ikke sikkerhetsjordingen fjernes fra UPS’en og det utstyret som er forbundet med den. S For å redusere fare for brann eller elektriske støt, bør denne UPS’en installeres i et innendørs miljø med kontrollert temperatur og luftfuktighet som er fritt for ledende, forurensende stoffer. Romtemperaturen må ikke overskride 40°C. Den må ikke brukes i nærheten av vann eller ved meget høy luftfuktighet (95% maks.). S Alt utstyr som er forbundet med utgangen av denne UPS’en må ikke ha en sterkere total lekkasjestrøm enn 1,5 milliampere for å være i overensstemmelse med internasjonale standarder og forkablingsbestemmelser. 12 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS FORSIKTIG S Batterier kan utgjøre en fare for elektrisk støt eller brannsår pga. høy kortsluttingsstrøm. Treff passende forholdsregler. Service bør utføres av kvalifisert servicepersonale med kjennskap til batterier og nødvendige forholdsregler. Hold uautorisert personale borte fra batteriene. S Batterier må fjernes på korrekt måte. Se lokale forskrifter vedrørende krav om fjerning av batterier. S Kast aldri batterier i flammer, da de kan eksplodere, hvis de utsettes for åpen ild. Regulamentos de Segurança INSTRUÇÕES DE SEGURANÇA IMPORTANTES GUARDE ESTAS INSTRUÇÕES Este manual contém instruções importantes que devem ser seguidas durante a instalação e manutenção do no-break e das baterias. Leia todas as instruções antes de operar o equipamento e guarde este manual para consultá-lo futuramente. CUIDADO A UPS contém VOLTAGEM MORTAL. Todos os reparos e assistência técnica devem ser executados SOMENTE POR PESSOAL DA ASSISTÊNCIA TÉCNICA AUTORIZADO. Não há nenhuma PEÇA QUE POSSA SER REPARADA PELO USUÁRIO dentro da UPS. ADVERTÊNCIA S Este no-break possui sua própria fonte de energia (baterias). As tomadas de saída podem estar energizadas mesmo que o no-break não esteja conectado a uma fonte de energia elétrica. S Nos modelos 220–240V, pode ser que as tomadas de saída permaneçam energizadas. Se a alimentação da sua aplicação for do tipo fase-neutro (como ocorre na maioria das aplicações na Europa), a tensão das tomadas de saída é de 0 V. Com a alimentação fase-fase, a tensão das tomadas de saída é de 110–120V (medida como fase-terra ou fase-neutro, dependendo da instalação elétrica do no-break). S Não remova ou desconecte o cabo de entrada quando a UPS estiver ligada. Isto removerá o aterramento de segurança da UPS e do equipamento conectado. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 13 SAFETY WARNINGS S Para reduzir o risco de incêndios ou choques elétricos, instale a UPS em ambiente interno com temperatura e umidade controladas e livres de contaminadores condutíveis. A temperatura ambiente não deve exceder 40°C. Não opere próximo a água ou em umidade excessiva (máx: 95%). S Para estar de acordo com os padrões internacionais e os regulamentos de fiação, o equipamento total conectado à saída desta UPS não deve ter uma corrente de fuga à terra maior que 1,5 miliampères. PERIGO S As baterias podem oferecer risco de choque elétrico ou queimadura, ocasionados por alta tensão com possibilidade de curto-circuito. Tome as precauções adequadas. A manutenção deve ser realizada por pessoal qualificado, com conhecimento sobre baterias e ciente das precauções exigidas. Mantenha o pessoal não autorizado afastado das baterias. S Siga as instruções apropriadas ao desfazer-se das baterias. Consulte os códigos do local para maiores informações sobre os regulamentos de descarte de produtos. S Nunca jogue as baterias no fogo, porque há risco de explosão. Предупреждения по мерам безопасности ВАЖНЫЕ УКАЗАНИЯ ПО МЕРАМ БЕЗОПАСНОСТИ СОХРАНИТЕ ЭТИ УКАЗАНИЯ В данном руководстве содержатся важные инструкции по установке и обслуживанию источника бесперебойного питания (ИБП) и батарей. Перед работой с оборудованием прочтите все инструкции. Сохраните данное руководство для дальнейшего использования. ОПАСНО В данном ИБП имеются СМЕРТЕЛЬНО ОПАСНЫЕ НАПРЯЖЕНИЯ. Все работы по ремонту и обслуживанию должны выполняться ТОЛЬКО УПОЛНОМОЧЕННЫМ ОБСЛУЖИВАЮЩИМ ПЕРСОНАЛОМ. Внутри ИБП нет узлов, ОБСЛУЖИВАЕМЫХ ПОЛЬЗОВАТЕЛЕМ. 14 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS ПРЕДУПРЕЖДЕНИЕ S В данном ИБП установлены собственные источники энергии (батареи). На выходных розетках может быть напряжение, даже если ИБП не подключен к сети переменного тока. S На выходных розетках моделей с напряжением 220-240 В может быть напряжение. Если устройство рассчитано на тип подключения “фаза-нейтраль” (как большинство устройств, изготавливаемых в Европе), напряжение на выходных розетках равно 0 В. При типе подключения “фаза-фаза” напряжение на выходных розетках составляет 110-120 В (при измерении “фаза-земля” или “фаза-нейтраль”, в зависимости от электрической схемы ИБП). S Не отсоединяйте сетевой шнур и не извлекайте его вилку из розетки при включенном ИБП. При этом защитное заземление отключается от ИБП и от оборудования, подключенного к ИПБ. S Для снижения опасности пожара или поражения электрическим током устанавливайте ИБП в закрытом помещении с контролируемыми температурой и влажностью, в котором отсутствуют проводящие загрязняющие вещества. Температура окружающего воздуха не должна превышать 40°С. Не эксплуатируйте устройство около воды или в местах с повышенной влажностью (макс. 95%). S Для обеспечения соблюдения требований международных стандартов и требований к разводке электрических цепей, суммарная величина тока утечки на землю всего оборудования, подключенного к выходу ИБП, не должна превышать 1,5 миллиампера. ОСТОРОЖНО S Высокое напряжение, вызванное коротким замыканием в батарее, может привести к поражению электрическим током или ожогу. Соблюдайте меры предосторожности. Техническое обслуживание должно осуществляться квалифицированным персоналом по работе с источниками питания, знакомым с мерами предосторожности. Не допускайте к работе с батареями посторонних. S Необходимо соблюдать правила утилизации аккумуляторов. Обратитесь к местным нормативным актам за информацией о требованиях к утилизации. S Никогда не бросайте аккумуляторы в огонь. Аккумуляторы могут взорваться под воздействием огня. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 15 SAFETY WARNINGS Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones importantes que debe seguir durante la instalación y el mantenimiento del SIE y de las baterías. Por favor, lea todas las instrucciones antes de poner en funcionamiento el equipo y guarde este manual para referencia en el futuro. PELIGRO Este SIE contiene VOLTAJES MORTALES. Todas las reparaciones y el servicio técnico deben ser efectuados SOLAMENTE POR PERSONAL DE SERVICIO TÉCNICO AUTORIZADO. No hay NINGUNA PARTE QUE EL USUARIO PUEDA REPARAR dentro del SIE. ADVERTENCIA S Este SIE contiene su propia fuente de energía (baterías). Los receptáculos de salida pueden transportar voltaje activo aun cuando el SIE no esté conectado con una fuente de CA. S Para los modelos 220–240V, es posible que los receptáculos de salida permanezcan eléctricamente activos. Si la fuente de energía de entrada de su aplicación está cableada de línea a neutro (como la mayoría de las aplicaciones europeas), el voltaje a los receptáculos de salida es 0V. Con cableado de entrada de línea a línea, el voltaje hacia los receptáculos de salida es 110–120V (medido de línea a tierra o de línea a neutro, lo que dependerá del cableado del SIE). S No retire o desenchufe el cable de entrada mientras el SIE se encuentre encendido. Esto suprime la descarga a tierra de seguridad del SIE y de los equipos conectados al SIE. S Para reducir el riesgo de incendio o de choque eléctrico, instale este SIE en un lugar cubierto, con temperatura y humedad controladas, libre de contaminantes conductores. La temperatura ambiente no debe exceder los 40°C. No trabaje cerca del agua o con humedad excesiva (95% máximo). S Para cumplir con los estándares internacionales y las normas de instalación, la totalidad de los equipos conectados a la salida de este SIE no debe tener una intensidad de pérdida a tierra superior a los 1,5 miliamperios. 16 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SAFETY WARNINGS PRECAUCIÓN S Las baterías pueden constituir un riesgo de descarga eléctrica o quemaduras por corriente alta de corto circuito. Adopte las precauciones debidas. Personal calificado de servicio que conozca de baterías y esté al tanto de las precauciones requeridas debe darle servicio al equipo. Mantenga al personal no autorizado alejado de las baterías. S Es necesario desechar las baterías de un modo adecuado. Consulte las normas locales para conocer los requisitos pertinentes. S Nunca deseche las baterías en el fuego. Las baterías pueden explotar si se las expone a la llama. Säkerhetsföreskrifter VIKTIGA SÄKERHETSFÖRESKRIFTER SPARA DESSA FÖRESKRIFTER Den här anvisningen innehåller viktiga instruktioner som du ska följa under installation och underhåll av UPS-enheten och batterierna. Läs alla instruktioner innan du använder utrustningen och spara den här anvisningen för framtida referens. FARA Denna UPS-enhet innehåller LIVSFARLIG SPÄNNING. ENDAST AUKTORISERAD SERVICEPERSONAL får utföra reparationer eller service. Det finns inga delar som ANVÄNDAREN KAN UTFÖRA SERVICE PÅ inuti UPS-enheten. VARNING S Den här UPS-enheten innehåller sin egen energikälla (batterier). Uttagen kan vara spänningsförande även då UPS-enheten inte är ansluten till spänningsnätet. S På modellerna 220 – 240 V kan de utgående uttagen fortfarande vara strömförande. Om den ingående strömkällan i din applikation är kopplad ledare-till-nolla (det vanligaste i Europa) är spänningen till de utgående uttagen 0 V. Är den ingående strömkällan kopplad ledare-till-ledare är spänningen i de utgående uttagen 110–120 V (uppmätt från ledare-till-jord eller ledare-till-nolla beroende på UPS:ens anslutning). S Ta aldrig bort nätsladden när UPS-enheten är påslagen. Detta tar bort skyddsjordningen från både UPS-enheten och den anslutna utrustningen. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 17 SAFETY WARNINGS S Minska risken för brand eller elektriska stötar genom att installera denna UPS-enhet inomhus, där temperatur och luftfuktighet är kontrollerade och där inga ledande föroreningar förekommer. Omgivande temperatur får ej överstiga 40°C. Använd inte utrustningen nära vatten eller vid hög luftfuktighet (max 95 %). S För att överensstämma med internationell standard och installationsföreskrifter får inte den totala utrustning som anslutits till uttagen på denna UPS-enhet ha läcksström som överstiger 1,5 milliampere. VIKTIGT S Batterierna kan innebära en risk för elektrisk stöt eller brännskada från kortsluten starkström. Iakttag lämpliga försiktighetsåtgärder. Service ska utföras av utbildad servicepersonal med kunskap om batterierna och nödvändiga försiktighetsåtgärder. Håll ej behörig personal borta från batterierna. S Batterierna måste avyttras enligt anvisningarna i lokal lagstiftning. S Använda batterier får aldrig brännas upp. De kan explodera. 18 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 3 Installation This section explains: S Equipment inspection S UPS internal battery connection S UPS setup and installation, including Extended Battery Modules (EBMs) S Remote emergency power-off (REPO) installation S UPS rear panels Inspecting the Equipment If any equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier or place of purchase and immediately notify your Avaya service representative. NOTE Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your Avaya service representative. Connecting the UPS Internal Battery To ensure proper battery operation: 1. Verify that the UPS is off and unplugged. 2. Remove the UPS front cover (see Figure 2). Figure 2. Removing the UPS Front Cover 3. Connect the internal battery connector (see Figure 3). Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 19 INSTALLATION Figure 3. Connecting the Internal Battery Connector 4. Replace the UPS front cover (see Figure 4). Figure 4. Replacing the UPS Front Cover 5. Continue to the following section, “UPS Setup.” UPS Setup The Avaya S9RM UPS is designed for flexible configurations and can be installed in a rack or as a standalone cabinet. If you are installing the UPS in a rack, continue to the following section “Rack-Mount Setup;” otherwise, continue to “Tower Setup” on page 22. 20 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C INSTALLATION Rack-Mount Setup The UPS can be installed in 19- or 23-inch racks and needs only 2U of valuable rack space. CAUTION The UPS and EBM are heavy (see page 56). A minimum of two people are required to lift the cabinets into the rack. NOTE Mounting rails are required for each UPS and EBM cabinet. If rails are not already installed in your rack, contact your local distributor to order rail kits. To install the UPS and optional EBMs in a rack: 1. Place the UPS on a flat, stable surface with the front of the UPS facing toward you. 2. Attach the supplied mounting handles to the mounting brackets and secure with the supplied screws (see Figure 5). 3. Align the mounting brackets with the screw holes on the sides of the UPS and secure with the supplied screws (see Figure 5). 4. If installing optional EBMs, repeat Steps 1 through 3 for each cabinet. Mounting Handle Mounting Bracket Figure 5. Installing the Mounting Handles and Brackets Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 21 INSTALLATION NOTE The EBMs must be installed below the UPS as shown in Figure 6. 5. Slide the UPS and any optional EBMs into the rack. 6. Secure the cabinets to the rack according to the rail kit instructions. 7. Continue to “Installing the UPS” on page 25 to complete the installation. UPS Optional EBMs Figure 6. Rack-Mount UPS with EBMs Tower Setup The tower setup varies depending on the number of cabinets you are installing: 1. For one cabinet, the pedestals must be installed. Continue to Step 2. For two or more cabinets, the joining brackets must be installed. Skip to Step 6. 2. Place the UPS cabinet horizontally so that the left end of the cabinet is accessible (see Figure 7). 3. Slide and align the UPS pedestals with the screw holes on the end of the UPS cabinet. Secure the pedestals with the screws provided in the accessory kit. Figure 7. Installing the UPS Pedestals 22 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C INSTALLATION 4. Carefully position the cabinet upright with the air vents at the top (see Figure 8). 5. Continue to “Installing the UPS” on page 25 to complete the installation. Air Vents Figure 8. UPS with Pedestals 6. Carefully position the cabinets upright with the air vents at the top (see Figure 9). Air Vents Figure 9. Tower UPS with EBMs Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 23 INSTALLATION 7. Remove the adjacent corner screws from the rear panels as shown in Figure 10 to install the joining brackets. Discard the screws. 8. Align each joining bracket with the screw holes and secure with the screws provided in the accessory kit. 9. If installing additional EBMs, repeat Steps 7 and 8 for each cabinet. 10. Continue to the following section, “Installing the UPS,” to complete the installation. Joining Bracket EBM UPS Joining Bracket Figure 10. Installing the Joining Brackets 24 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C INSTALLATION Installing the UPS NOTE Do not make unauthorized changes to the UPS or accessories; otherwise, damage may occur to your equipment and void your warranty. Figure 11 shows a typical installation only. See “UPS Rear Panels” on page 29 for the rear panel of each model. To install the UPS and optional EBMs: 1. If installing an optional EBM, continue to Step 2; otherwise, skip to Step 3. 2. Plug the EBM cable(s) into the battery connector(s) as shown in Figure 11. Up to four EBMs may be connected to the UPS. ConnectUPS-X Web/SNMP Card Power Cord Output Receptacles UPS UPS Battery Connector EBM Cable EBM EBM EBM Battery Connectors Figure 11. Typical UPS Installation with Two EBMs 3. Plug the equipment to be protected into the appropriate UPS output receptacles (see page 47 for more information on load segments). NOTE DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating elements. 4. If an emergency power-off (disconnect) switch is required by local codes, see the following section, “Remote Emergency Power-off Installation,” to install the REPO switch before powering on the UPS. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 25 INSTALLATION 5. For 230V models only. Plug the detachable UPS power cord into the input connector on the UPS rear panel. 6. Plug the UPS power cord into a power outlet. All front panel indicators flash briefly and the UPS conducts a indicator flashes, self-test. When the self-test is complete, the indicating the UPS is in Standby mode with the equipment offline. If or indicator flashes, see page 61. the μ Battery Service Indicator Site Wiring Fault Indicator Figure 12. Fault Indicators 7. Press the On button. μ The indicator illuminates solid and the bar graph indicators display the percentage of load being applied to the UPS. The UPS is now in Normal mode and supplying power to your equipment. To change the factory-set defaults, see “Configuration Mode” on page 37. NOTE The batteries charge to 80% capacity in approximately 2 hours. However, it is recommended that the batteries charge for 36 hours after installation or long-term storage. NOTE If you installed power management software and optional EBMs, ensure maximum battery runtime by using the ERM Configurator tool on the Software Suite CD and connecting a minimum load of 10% (15% recommended) to the UPS. See page 40 to install the ERM Configurator tool with a ConnectUPS-X Web/SNMP Card. 26 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C INSTALLATION Remote Emergency Power-off Installation The Avaya S9RM includes a REPO port that allows power to be switched off at the UPS output receptacles from a customer-supplied switch in a remote location. The REPO feature shuts down the protected equipment immediately and does not follow the orderly shutdown procedure initiated by any power management software. Any devices that are operating on battery power are also shut down immediately. When the REPO switch is reset, the equipment will not return to battery power until the UPS is manually restarted. button is pressed after the REPO is activated, the UPS If the Off remains in Standby mode when restarted until the On button is pressed. WARNING The REPO circuit is an IEC 60950 safety extra low voltage (SELV) circuit. This circuit must be separated from any hazardous voltage circuits by reinforced insulation. CAUTION To ensure the UPS stops supplying power to the load during any mode of operation, the input power must be disconnected from the UPS when the emergency power-off function is activated. NOTE The REPO function activates when the REPO contacts close. NOTE For Europe, the emergency switch requirements are detailed in Harmonized document HD-384-48 S1, “Electrical Installation of the Buildings, Part 4: Protection for Safety, Chapter 46: Isolation and Switching.” To install the REPO switch: 1. Verify that the UPS is off and unplugged. 2. Remove the REPO connector from the accessory kit. 3. Connect isolated, normally-open, dry contacts (rated to handle 60 Vdc maximum, 30 Vac RMS maximum, and 20 mA maximum) across the REPO device to Pin 1 and Pin 2 (see Figure 13). Use stranded, non-shielded wiring, size 0.75 mm2–0.5 mm2 (18–20 AWG). Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 27 INSTALLATION NOTE A separate contact must simultaneously cause UPS input AC power to be removed. Pin 1 Pin 2 Figure 13. REPO Connector 4. Connect the REPO connector to the REPO port on the UPS rear panel. 5. Verify that the externally-connected REPO switch is not activated to enable power to the UPS output receptacles. 6. Plug in the UPS and start the UPS by pressing the On button. 7. Activate the external REPO switch to test the REPO function. 8. De-activate the external REPO switch and restart the UPS. 9. If you are installing power management software, refer to the ConnectUPS Web/SNMP Card Quick Start Instructions and ConnectUPS Web/SNMP Card User’s Guide on the Software Suite CD for configuration instructions. For 2000 VA models with an Alarm Adapter, connect your computer to the UPS communication port using the supplied communication cable. 28 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C INSTALLATION UPS Rear Panels This section shows the rear panels of the Avaya S9RM models. ConnectUPS-X Web/SNMP Card 5-15 Receptacles Network Transient Protector Battery Connector Power Cord with 5-15 Plug REPO Port Figure 14. 1000–1500 VA, 120V Rear Panel Circuit Breakers 9-Pin Communication Port 25-Pin Communication Port 5-20 Receptacles Alarm Adapter 5-15 Receptacles Network Transient Protector Battery Connector Power Cord with 5-20 Plug REPO Port Figure 15. 2000 VA, 120V Rear Panel (with 5-20R) ConnectUPS-X Web/SNMP Card IEC-320 Input Connector IEC-320 Receptacles Battery Connector REPO Port Network Transient Protector Figure 16. 700–1500 VA, 230V Rear Panel Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 29 INSTALLATION 30 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 4 Operation This section describes: S Turning the UPS on and off S Starting the UPS on battery S Initiating the self-test S Operating modes Turning the UPS On After the UPS is connected to a power outlet, it conducts a self-test and enters Standby mode. To turn on the UPS, press the On button on the front panel. The indicator illuminates solid and the bar graph indicators display the percentage of load being applied to the UPS. μ Starting the UPS on Battery To turn on the UPS without using utility power, press and hold the On button for at least four seconds. The UPS starts up in Battery mode and supplies battery power to your equipment. When the UPS starts on battery, it does not conduct a self-test to conserve battery power. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 31 OPERATION Turning the UPS Off NOTE Pressing the Off down immediately. button while the UPS is in Battery mode causes the UPS to shut To turn off the UPS: 1. Prepare your equipment for shutdown. 2. Press and hold the Off button for approximately three seconds. The UPS transfers to Standby mode (if utility power is available) and removes power from your equipment. 3. Unplug the UPS; the UPS shuts down in five seconds. All front panel indicators flash briefly twice prior to shutdown. If you do not unplug the UPS, it remains in Standby mode. Initiating the Self-Test NOTE The batteries must be fully charged and the UPS must not be in Battery mode to perform the self-test. NOTE Load must be applied to the UPS to perform the battery test. Apply the following load amounts according to the UPS rating: 50% load for 700 VA; 35% load for 1000 VA; 38% load for 1500 VA; or 25% load for 2000 VA. Press and hold the button for three seconds to initiate the self-test. During the five-second test, the bar graph indicators cycle through twice. If the alarm beeps or a UPS alarm indicator stays on, see Table 11 on page 60. 32 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C OPERATION Operating Modes The Avaya S9RM front panel indicates the UPS status through the UPS indicators. Figure 17 shows the UPS front panel indicators and controls. Normal Mode Indicator Alarm Indicators (see page 59) Battery Mode Indicator Bar Graph Indicators Bypass Mode Indicator Indicator Legend Unlit Test/Alarm Reset Button Lit Flashing Off Button On Button Figure 17. UPS Front Panel Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 33 OPERATION Normal Mode μ During Normal mode, the indicator illuminates and the front panel displays the percentage of UPS load capacity being used by the protected equipment (see Figure 18). The UPS monitors and charges the batteries as needed and provides power protection to your equipment. <10% 10–25% 26–50% 51–75% 76–100% >100% Figure 18. Load Level Indicators When all of the bar graph indicators are illuminated and the indicator flashes, power requirements exceed UPS capacity; see page 62 for more information. 34 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C OPERATION Battery Mode When the UPS is operating during a power outage, the alarm beeps once per second and the + --- indicator illuminates. The front panel displays the approximate percentage of battery capacity remaining (see Figure 19). >75% >50% >25% Low Battery Warning Shutdown Imminent Figure 19. Battery Capacity Indicators If battery capacity becomes low while in Battery mode, the indicator starts flashing and the alarm becomes continuous. This warning is approximate, and the actual time to the Shutdown Imminent warning may vary significantly. NOTE Depending on the UPS load and number of Extended Battery Modules (EBMs), the Low Battery warning may occur before the batteries reach 25% capacity. See Table 10 on page 58 for estimated runtimes. When shutdown is imminent, the indicator flashes. Immediately complete and save your work to prevent data loss and similar difficulties. If utility power returns before UPS shutdown, the UPS transfers to Normal mode operation while the battery recharges. If utility power returns after UPS shutdown, the UPS automatically restarts. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 35 OPERATION Bypass Mode In the event of a UPS overload or internal failure, the UPS transfers your equipment to utility power. Battery mode is not available; however, the utility power continues to be passively filtered by the UPS. The indicator illuminates. The UPS transfers to Bypass mode when: S The UPS has an overtemperature condition. S The UPS has an overload condition of 101 to 110% for 2 minutes. S The UPS has an overload condition of 111 to 150% for 30 seconds. S The UPS detects a fault in the battery or UPS electronics. Standby Mode When the UPS is turned off and remains plugged into a power outlet, indicator flashes and the bar graph the UPS is in Standby mode. The indicators are off, indicating that power is not available to your equipment. The battery recharges when necessary. μ NOTE For 220–240V models, the output receptacles may remain electrically live (up to 110–120V). Unplug the UPS to ensure power is not available to the output receptacles. 36 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 5 Configuration This section describes: S Using Configuration mode to change the input voltage, site wiring fault, and AC input alarm. S Using the ERM Configurator tool with a ConnectUPS-X Web/SNMP Card Configuration Mode When the UPS is in Configuration mode, the bar graph indicators represent the configuration options. Use the control buttons button) to modify the UPS configuration. Figure 20 (On button and shows the LEDs and Table 1 explains the corresponding options. NOTE The UPS can be configured while in Battery mode. If the UPS transfers to battery power while in Configuration mode, the UPS remains in Configuration mode and indicates Battery mode on the front panel after exiting Configuration mode. CAUTION DO NOT press the Off button while the UPS is in Configuration mode; pressing the Off button removes all power to your equipment immediately and the UPS enters Standby mode. To reconfigure the UPS default settings: 1. Press and hold the On button and the button simultaneously for approximately three seconds. The UPS transfers to Configuration mode. The LEDs flash briefly and then display the enabled options. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 37 CONFIGURATION 2. Press the On button to scroll through the options. Each time you press the button, the UPS beeps. The LED for the selected option indicates the current setting; flashing represents disabled options (see Figure 20 and Table 1). Scrolling past the last LED returns to the first configuration option. If you press the On button and nothing happens, the UPS is still in Operation mode. Repeat Step 1 to enter Configuration mode, and then perform Step 2. 3. button ONCE to select the Voltage option or to toggle Press the the Site Wiring Fault Alarm or AC Input Failure Alarm on or off. NOTE The UPS automatically exits Configuration mode after two minutes. 4. Press and hold the On button and the button simultaneously for three seconds to exit Configuration mode at any time. Configuration Mode LEDs 1 & 4 3 Press the Test/Alarm Reset button ONCE to select an option. Test/Alarm Reset Button On Button Press and hold the On and Test/Alarm Reset buttons simultaneously for three seconds to toggle between Configuration and Operation modes. 2 Press the On button to scroll to the next option. Figure 20. Using Configuration Mode 38 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C CONFIGURATION Table 1. Configuration Mode LEDs and Options Configuration Mode LEDs Option LED Status Explanation 120/230V Nominal Input Voltage On (default) Nominal input voltage is 120V for low voltage models and 230V for high voltage models. All other nominal input voltages are disabled. Flashing 120/230V is disabled; one of the other input voltage options is selected. On Nominal input voltage is 110V for low voltage models 220V for high voltage models. All other nominal input voltages are disabled. Flashing (default) 110/220V is disabled; one of the other input voltage options is selected. On Nominal input voltage is 127V for low voltage models and 240V for high voltage models. All other nominal input voltages are disabled. Flashing (default) 127/240V is disabled; one of the other input voltage options is selected. On (default) Alarm sounds when the polarity of the outlet is reversed or the ground connection is missing; have a qualified electrician repair the outlet wiring. Flashing* Alarm DOES NOT sound when the polarity of the outlet is reversed or the ground connection is missing. * For 230V models, Site Wiring Fault is not available (flashing is the only status). On (default) Alarm sounds when there is an AC input failure. Flashing Alarm DOES NOT sound when there is an AC input failure. 110/220V Nominal Input Voltage 127/240V Nominal Input Voltage Site Wiring Fault Alarm AC Input Failure NOTE 208V nominal input voltage is available. Contact your Avaya service representative for assistance. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 39 CONFIGURATION Installing ERM Configurator with a ConnectUPS-X Web/SNMP Card During normal operation, the ConnectUPS-X Web/SNMP Card controls the communication path to the UPS and allows network-based access to UPS data through the Web and SNMP. Some situations require direct serial communication to the UPS in a pass-through mode, such as running the ERM Configurator tool. The following instructions disable the card’s Normal mode of operation so that Serial Pass-Through mode is available. Placing the Card into Serial Pass-Through Mode NOTE Serial pass-through functionality is available only with the ConnectUPS-X Web/SNMP Card firmware v3.20 and higher (with older, non-RoHS hardware) and v4.20 and higher (with RoHS hardware). Updates to the ConnectUPS-X Web/SNMP Card firmware are available at www.powerware.com/avaya. To place the ConnectUPS-X Web/SNMP Card into Serial Pass-Through mode: 1. Note the current position of DIP switches on the card [the default setting for both switches is the 0 (off) position]. Write them here for later reference. DIP Switch 1 _____ 0 (off) _____ 1 (on) DIP Switch 2 _____ 0 (off) _____ 1 (on) 2. Set both DIP switches to the 1 (on) position for Serial Pass-Through mode. 3. Using a pen or paperclip, press the RESET switch on the card to restart the card in the Serial Pass-Through mode. 4. Locate the configuration cable (labeled “PC”) that was supplied with the ConnectUPS-X Web/SNMP Card. 5. Plug the RJ-45 end of the configuration cable into the COM port on the card. Verify that you have used the port labeled “COM.” The other ports on the card will not work for configuration. 6. 40 Plug the other end of the configuration cable into the serial COM port on the computer. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C CONFIGURATION 7. Set up the PC to communicate with the UPS serially: S Open your terminal emulation program (such as HyperTerminal®). S Select the appropriate serial connection (such as COM1). S Set the serial line to 9600 baud, No parity, 8 data bits, 1 stop bit, and no flow control. 8. From the Start menu select Programs, UPS, and then ERM Configurator. ERM Configurator opens. 9. Change the baud setting to 9600 by clicking Port, setting the baud rate, and clicking Apply. 10. Click Connect to establish communication with the UPS. The message “Connecting ... UPS Found ... Done” confirms that the UPS is connected, and the UPS Connection Status indicator changes from red to green. 11. To change the number of EBMs associated with the UPS, click ERM. The ERM Options screen opens (see Figure 21). Figure 21. ERM Options Screen 12. Select the correct number of EBMs. The number should reflect the number of EBMs associated with the UPS. Selecting “0” indicates the presence of only the UPS internal battery. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 41 CONFIGURATION 13. Click Apply to save the change. The Update ERM Configuration screen opens. 14. Confirm the change by clicking Yes. The update completes, and the ERM Options screen opens again. 15. Click Exit. Exiting Serial Pass-Through Mode After using the card in Serial Pass-Through mode, restart the card in Normal mode: 42 1. Disconnect the configuration cable from the card and PC. 2. Return the card’s switches to the original settings noted in Step 1 on page 40. 3. Using a pen or paperclip, press the RESET switch on the ConnectUPS-X Web/SNMP Card to restart the card in Normal mode. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 6 Additional UPS Features This section describes: S ConnectUPS-X Web/SNMP Card S The Alarm Adapter S Network transient protector S Load segments ConnectUPS-X Web/SNMP Card The ConnectUPS-X Web/SNMP Card is a network device for your UPS that provides both SNMP and HTTP compatibility. It has a built-in switching hub that allows three additional network devices to be connected to the network without the requirement of additional network drops. With the ConnectUPS-X card, you can monitor the UPS several different ways: S Using a Web browser such as MicrosoftR Internet Explorer to monitor and manage the connected UPS S Using your Internet-ready cell phone or PDA (personal digital assistant) S Using SNMP-compatible network management software (user-supplied) that monitors the UPS in a method similar to that of other network devices Refer to the Powerware ConnectUPS Web/SNMP Card User’s Guide on the Software Suite CD for more information. 10 Mb Network LEDs (yellow) Uplink Ethernet Connector Power LED (green) 100 Mb Network LEDs (green) Status LED (yellow) Off 1 2 On Additional Ethernet Connectors COM Port DIP Switch Reset Button Figure 22. ConnectUPS-X Panel Details Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 43 ADDITIONAL UPS FEATURES The Alarm Adapter The Alarm Adapter has a 9-pin and a 25-pin communication port. The 9-pin port provides standard serial communication, and the 25-pin port provides isolated signals. The cable pins are identified in NO TAG and the pin functions are described in Table 2 and Table 3. Alarm Adapter 5 4 3 9 13 12 11 10 9 25 24 23 22 8 8 21 2 7 7 1 6 6 5 4 20 19 18 17 16 3 2 1 15 14 Figure 23. The Alarm Adapter Table 2. 9-Pin Assignment 44 Pin Number Signal Name Function Direction from the UPS 1 — No connection — 2 TxD Transmit to external device Out 3 RxD Receive from external device In 4 DTR PnP (Plug and Play) from external device (tied to Pin 6) In 5 GND Signal common — 6 DSR To external device (tied to Pin 4) Out 7 — No connection — 8 — No connection — 9 Power Source +V (8 to 24 volts DC power) Out Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C ADDITIONAL UPS FEATURES Table 3. 25-Pin Assignment Pin Number Signal Name/Relay Function 7 GND Signal common 8 Power Source +V (8 to 24 volts DC power) 14 Normally Open Relay 2 Utility fail 15 Common Relay 2 Utility fail return 18 Common Relay 3 UPS on bypass return 19 Normally Open Relay 3 UPS on bypass 24 Normally Open Relay 4 Battery low 25 Common Relay 4 Battery low return NOTE No connection on pins 1-6, 9-13, 16, 17, and 20-23. To establish communication between the UPS and a computer, connect your computer to the UPS communication port using the supplied communication cable. When the communication cable is installed, power management software can exchange data with the UPS. The software polls the UPS for detailed information on the status of the power environment. If a power emergency occurs, the software initiates the saving of all data and an orderly shutdown of the equipment. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 45 ADDITIONAL UPS FEATURES Network Transient Protector The network transient protector, shown in Figure 24, is located on the rear panel and has jacks labeled IN and OUT. This feature accommodates a single RJ-45 (10BaseT) network connector. Low voltage models can also accommodate an RJ-11 telephone connector that provides protection for modems, fax machines, or other telecommunications equipment. As with most modem equipment, it is not advisable to use this jack in digital PBX (Private Branch Exchange) environments. NOTE DO NOT connect any telephone or fax/modem equipment to the 230V models; only network protection is available for 230V models. 1. Connect the network or telephone (low voltage models only) cable to the jack labeled IN. 2. Connect the input connector of the equipment you are protecting to the jack labeled OUT. IN OUT IN OUT NETWORK TRANSIENT PROTECTOR Figure 24. Network Transient Protector 46 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C ADDITIONAL UPS FEATURES Load Segments Load segments are sets of receptacles that can be controlled by power management software, providing an orderly shutdown and startup of your equipment. For example, during a power outage, you can keep key pieces of equipment running while you turn off other equipment. This feature allows you to save battery power. See your power management software manual for details (refer to the Software Suite CD or www.powerware.com/avaya for the latest information). NOTE If power management software is not used, the individual load segments cannot be controlled. Each UPS has two load segments as shown in Figure 25 and Figure 26. Figure 25 shows the load segments for all models except the PW9125 2000 20R model (shown in Figure 26). Load Segment 2 Load Segment 1 Figure 25. UPS Load Segments (120V Model Shown) Load Segment 1 Load Segment 2 Figure 26. UPS Load Segments for PW9125 2000 20R Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 47 ADDITIONAL UPS FEATURES 48 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 7 UPS Maintenance This section explains how to: S Care for the UPS and batteries S Replace the batteries S Test new batteries S Recycle used batteries or UPS UPS and Battery Care For the best preventive maintenance, keep the area around the UPS clean and dust-free. If the atmosphere is very dusty, clean the outside of the system with a vacuum cleaner. For full battery life, keep the UPS at an ambient temperature of 25°C (77°F). NOTE If the UPS requires any type of transportation, verify that the UPS is unplugged and turned off and then disconnect the UPS internal battery connector using the steps in “Connecting the UPS Internal Battery” on page 19 in reverse order. NOTE The batteries in the UPS are rated for a 3–5 year service life. The length of service life varies, depending on the frequency of usage and ambient temperature. Batteries used beyond expected service life will often have severely reduced runtimes. Replace batteries at least every 5 years to keep units running at peak efficiency. Storing the UPS and Batteries If you store the UPS for a long period, recharge the battery every 12 months by plugging the UPS into a power outlet. The batteries charge to 80% capacity in approximately 2 hours. However, it is recommended that the batteries charge for 36 hours after long-term storage. Check the battery recharge date on the shipping carton label. If the date has expired and the batteries were never recharged, do not use the UPS. Contact your Avaya service representative. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 49 UPS MAINTENANCE When to Replace Batteries When the indicator flashes, the batteries may need replacing. button for three Conduct a self-test by pressing and holding the seconds. NOTE The batteries must be fully charged and the UPS must not be in Battery mode to perform the self-test. NOTE Load must be applied to the UPS to perform the battery test. Apply the following load amounts according to the UPS rating: 50% load for 700 VA; 35% load for 1000 VA; 38% load for 1500 VA; or 25% load for 2000 VA. After the test is complete, the indicator should turn off (it may take a indicator continues to flash, contact few seconds to turn off). If the your Avaya service representative to order new batteries. Replacing Batteries NOTE DO NOT DISCONNECT the batteries while the UPS is in Battery mode. With the hot-swappable battery feature, UPS batteries can be replaced easily without turning the UPS off or disconnecting the load. If you prefer to remove input power to change the batteries, see “Turning the UPS Off” on page 32. Consider all warnings, cautions, and notes before replacing batteries. WARNING S Batteries can present a risk of electrical shock or burn from high short-circuit current. The following precautions should be observed: 1) Remove watches, rings, or other metal objects; 2) Use tools with insulated handles; 3) Do not lay tools or metal parts on top of batteries. S ELECTRIC ENERGY HAZARD. Do not attempt to alter any battery wiring or connectors. Attempting to alter wiring can cause injury. 50 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C UPS MAINTENANCE How to Replace Internal Batteries CAUTION Pull the battery out onto a flat, stable surface. The battery is unsupported when you pull it out of the UPS. To replace the UPS internal batteries: 1. Remove the UPS front cover (see Figure 27). NOTE DO NOT attempt to open the left side. Figure 27. Removing the UPS Front Cover 2. Unscrew and set aside the battery retaining bracket (see Figure 28). 3. Disconnect the battery cable from the UPS battery connector and remove the battery cable from the wire clips. Battery Connector Battery Retaining Bracket Wire Clips Figure 28. Accessing the UPS Internal Battery Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 51 UPS MAINTENANCE 4. Pull the battery out onto a flat, stable surface (see Figure 29). See “Recycling the Used Battery or UPS” on page 54 for proper disposal. Figure 29. Removing the Battery 5. Slide the new battery into the UPS. 6. Reconnect the battery cable and secure the battery cable in the wire clips. 7. Reinstall the battery retaining bracket and screws removed in Step 2. 8. Replace the UPS front cover. How to Replace Extended Battery Modules CAUTION The Extended Battery Module (EBM) is heavy (see page 56). A minimum of two people are required to lift the cabinets into the rack. To replace the EBMs: 1. Unplug the EBM cable from the UPS. If additional EBMs are installed, unplug the EBM cable from the battery connector on each EBM. 52 2. If the EBM is in a tower configuration, remove the joining brackets. 3. If the EBM is in a rack, install the supplied mounting handles and brackets on the new EBM. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C UPS MAINTENANCE 4. Replace the EBM. See “Recycling the Used Battery or UPS” on page 54 for proper disposal. 5. Reinstall the joining brackets if removed in Step 2. 6. Plug the new EBM into the UPS as shown in Figure 30. For additional EBMs, plug the EBM cable into the battery connector on the adjacent EBM. Joining Brackets EBM Battery Connectors UPS Battery Connector EBM Cables Figure 30. EBM Connections (120V Model Shown) NOTE The battery connectors are designed to ensure proper connection with the correct EBM model (use EBM model EBM 24 with 1000–1500 VA UPSs and EBM model EBM 48 with 700–1500 VA UPSs). Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 53 UPS MAINTENANCE Testing New Batteries NOTE The batteries must be fully charged and the UPS must not be in Battery mode to perform the self-test. NOTE Load must be applied to the UPS to perform the battery test. Apply the following load amounts according to the UPS rating: 50% load for 700 VA; 35% load for 1000 VA; 38% load for 1500 VA; or 25% load for 2000 VA. Press and hold the button for three seconds to initiate a self-test. indicator should turn off (it may take a After the test is complete, the indicator continues to flash, check few seconds to turn off). If the the battery connections. Call your Avaya service representative if the problem persists. Recycling the Used Battery or UPS Contact your local recycling or hazardous waste center for information on proper disposal of the used battery or UPS. WARNING S Do not dispose of the battery or batteries in a fire. Batteries may explode. Proper disposal of batteries is required. Refer to your local codes for disposal requirements. S Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. CAUTION Do not discard the UPS or the UPS batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly. For more information, contact your local recycling/reuse or hazardous waste center. CAUTION Do not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. 54 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 8 Specifications This section provides the following specifications: S Parts list S Weights and dimensions S Electrical input and output S Environmental and safety S Battery Table 4. Parts List Item Comcode Description 1000 Model UPS 700290273 1000 VA, 120V UPS Module 1500 Model UPS 194384 1500 VA, 120V UPS Module 2000 Model (with 5-20R) UPS 700019300 2000 VA, 120V UPS Module (with 5-20 receptacles) 700i Model UPS 408427409 700 VA, 230V UPS Module 1000i Model UPS 700404387 1000 VA, 230V UPS Module 1500i Model UPS 700395734 1500 VA, 230V UPS Module EBM 24 700404411 Battery Module for the 1000 Model EBM 48 700404429 Battery Module for the 1500 Model Rail Kit, 4-Post 700404502 4-Post Rail Kit Rail Kit, 2-Post 700404494 2-Post Rail Kit Seismic Kit, 3-Slot 700404510 3-Slot Earthquake Kit Seismic Kit, 5-Slot 700404528 5-Slot Earthquake Kit ConnectUPS-X Web/SNMP Card 700404759 ConnectUPS-X Web/SNMP Card Extended Battery Cabinet, 48 Vdc 700404486 48 Vdc Extended Battery Cabinet (XBU48) BDM 408357077 Bypass Distribution Module, 1000–1500 VA UPS, 120V BDM 408357093 Bypass Distribution Module, 2000 VA, 120V BDM 700404460 Bypass Distribution Module, 230V Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 55 SPECIFICATIONS Table 5. Weights and Dimensions Dimensions (WxDxH) Weights UPS Extended Battery Module (EBM) 43.2 x 49.3 x 8.9 cm 17.0” x 19.4” x 3.5” (2U) 43.2 x 49.3 x 8.9 cm 17.0” x 19.4” x 3.5” (2U) 700–1000 VA: 15 kg (34 lb) 1500–2000 VA: 23 kg (50 lb) 29.5 kg (65 lb) 120V Models 230V Models 120V default; 110, 120, 127V selectable* 230V default; 220, 230, 240V selectable* 80–144V for 110, 120, 127V nominal 160–288V for 220, 230, 240V nominal Table 6. Electrical Input Nominal Voltage Voltage Range Nominal Frequency Noise Filtering Connections 45–65 Hz, 50/60 Hz auto-sensing MOVs and line filter for normal and common mode noise 1000–1500 VA: 6-ft, 5-15P power cord 2000 VA: 6-ft, 5-20P power cord 10A, IEC 320-C14 input connector * 208V nominal input voltage is available. Contact your Avaya service representative for assistance. Table 7. Electrical Output 120V Models Power Levels (Rated at Nominal Inputs) 230V Models 1000 Model: 1000 VA, 700W 1500 Model: 1500 VA, 1050W 2000 Model (with 5-20R): 2000 VA, 1400W 700i Model: 700 VA, 490W 1000i Model: 1000 VA, 700W 1500i Model: 1500 VA, 1050W Regulation (Normal Mode) Nominal output voltage ±3% Regulation (Battery Mode) Nominal output voltage ±3% Voltage Waveform Output Receptacles 56 Normal mode: Sine wave; <5% THD with full PFC and nonlinear load (6) 5-15R 2000 Model (with 5-20R) only: (2) 5-20R, (4) 5-15R (6) IEC-320 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C SPECIFICATIONS Table 8. Environmental and Safety 120V Models Operating Temperature 230V Models 0°C to 40°C (32°F to 104°F) Optimal battery performance: 25°C (77°F) Storage Temperature 0°C to 25°C (32°F to 77°F) Transit Temperature -25°C to 55°C (-13°F to 131°F) Relative Humidity 5–90% noncondensing Operating Altitude Up to 3,000 meters above sea level Transit Altitude Heat Dissipation (Recharge Mode up to 8 Hours) Up to 10,000 meters above sea level 1000 VA: 601 BTU/hr 1500 VA: 986 BTU/hr 2000 VA: 1201 BTU/hr 700 VA: 472 BTU/hr 1000 VA: 601 BTU/hr 1500 VA: 986 BTU/hr Audible Noise Less than 45 dBA Normal mode, typical load Less than 50 dBA Battery mode Surge Suppression ANSI C62.41 Category B (formerly IEEE 587) Safety Conformance Agency Markings EMC (Class B) UL 1778, UL 497A; CSA C22.2, No. 107.1, 107.2; NOM-019-SCFI UL 1778, UL 497A; CSA C22.2, No. 107.1, 107.2; EN 62040-1-1 and IEC 60950-1; NOM-019-SCFI cULus, NOM cULus, CE, NOM, NEMKO FCC Part 15, ICES-003, VCCI EN 50091-2, FCC Part 15, ICES-003, VCCI Table 9. Battery UPS Configuration 700–1000 VA: (2) 12V, 9 Ah internal batteries 1500–2000 VA: (4) 12V, 9 Ah internal batteries EBM Configuration EBM 24: (8) 12V, 9 Ah EBM 48: (8) 12V, 9 Ah Type Charging Monitoring Sealed, maintenance-free, valve-regulated, lead-acid Internal battery: approximately 2 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge Advanced monitoring for earlier failure detection and warning Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 57 SPECIFICATIONS Table 10. Battery Runtimes (in Minutes) 700–1000 VA Models Load UPS Internal Batteries +1 EBM +2 EBMs 200 VA/140W 37 271 546 400 VA/280W 19 142 278 700 VA/490W 9 72 156 850 VA/595W* 6 59 124 1000 VA/700W* 5 48 104 +3 EBMs +4 EBMs * Runtimes do not apply for 700 VA models. 1500–2000 VA Models Load UPS Internal Batteries +1 EBM +2 EBMs +3 EBMs +4 EBMs 400 VA/280W 46 177 331 501 682 700 VA/490W 25 96 180 272 370 850 VA/595W 21 76 142 214 292 1000 VA/700W 16 61 115 174 237 1250 VA/875W 11 46 87 131 179 1500 VA/1050W 8 37 70 106 144 1800 VA/1260W** 6 30 57 85 116 2000 VA/1400W** 5 26 49 74 100 ** Runtimes do not apply for 1500 VA models. NOTE Battery times are approximate and vary depending on the load configuration and battery charge. 58 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C Chapter 9 Troubleshooting This section explains: S UPS alarms and conditions S How to silence an alarm S Service and support Audible Alarms and UPS Conditions The UPS has an audible alarm feature to alert you of potential power problems. Use Table 11 to determine and resolve the UPS alarms and conditions. NOTE Some alarms, such as the Overtemperature and Overload alarms, must be cleared by shutting down and restarting the UPS (see page 62 for more information). Site Wiring Fault Battery Service Overtemperature Overload Self-Test Indicator Legend Unlit Test/Alarm Reset Button Lit Flashing Figure 31. Alarm Indicators Silencing an Audible Alarm Before silencing an alarm, check the alarm condition and perform the applicable action to resolve the condition (see Table 11). button. If UPS To silence the alarm for an existing fault, press the status changes, the alarm beeps, overriding the previous alarm silencing. Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 59 TROUBLESHOOTING Table 11. Troubleshooting Guide Alarm or Condition Possible Cause μ The indicator is not on; The UPS internal battey is not connected. the UPS does not start. μ The indicator is flashing; power is not available at the UPS output receptacles. Action See “Connecting the UPS Internal Battery” on page 19. The power cord is not connected correctly. Check the power cord connections. The wall outlet is faulty. Have a qualified electrician test and repair the outlet. The remote emergency power-off (REPO) switch is active. Reset the REPO switch and restart the UPS. The UPS is in Standby mode. Press the On | button to supply power to the connected equipment. The UPS operates normally, The equipment is not but some or all of the connected to the UPS protected equipment is not correctly. on on. The output receptacle circuit breaker (2000 VA only) is open. Verify that the equipment is plugged into the UPS receptacles. Check the load. Disconnect faulty load equipment. Wait several minutes before resetting the UPS circuit breaker. One of the load segments Reactivate the segment with the software. has been turned off through the power management software. Output circuit breaker trips (2000 VA only). Load fault. Check the load. Disconnect faulty load equipment. Wait several minutes before resetting the UPS circuit breaker. The UPS does not provide the expected backup time. The battery needs charging or service. Plug the UPS into a power outlet for 36 hours to charge the battery. After charging the battery, press and hold the button for 3 seconds; then check the indicator. If the indicator is still flashing, see “Replacing Batteries” on page 50. Power management software shut down the UPS prematurely. Verify that the ERM Configurator tool on the Software Suite CD was installed (see page 40). Verify that the power management software settings are configured for the appropriate shut down times. 60 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C TROUBLESHOOTING Alarm or Condition Battery Intermittent audible alarm Possible Cause Action The UPS is on battery (see “Battery Mode” on page 35 for more information). The UPS is powering the equipment with battery power. Check the bar graph indicators for available battery capacity and prepare your equipment for shutdown. Low Battery warning. This warning is approximate, and the actual time to the Shutdown Imminent warning may vary significantly. Depending on the UPS load and number of Extended Battery Modules (EBMs), the Low Battery warning may occur before the batteries reach 25% capacity. See Table 10 on page 58 for estimated runtimes. Shutdown imminent. Prepare for a shutdown. Save your work and turn off your equipment. Warning - Low Battery Shutdown - Low Battery Bypass The UPS is in Bypass mode. The equipment is transferred to utility power; however, the utility power continues to be passively filtered by the UPS. Check for one of the following alarms: Overtemperature, Overload, or Battery Service. Bypass Bypass is not available. Input voltage is not within ±12% of nominal or input frequency is not within ±3% of nominal. The UPS is receiving utility power that may be unstable or in brownout conditions. The UPS continues to supply power to your equipment. If conditions worsen, the UPS may switch to battery power. The battery may be fully discharged. Plug the UPS into a power outlet for 36 hours to charge the battery. After charging the battery, press and hold the button for 3 seconds; then check the indicator. If the indicator is still flashing, see “Replacing Batteries” on page 50. The battery is not connected correctly. Check the battery connections. Call your Avaya service representative if the problem persists. Ground wire connection does not exist or the line and neutral wires are reversed in the wall outlet. Have a qualified electrician correct the wiring. To disable this alarm, see “Configuration” on page 37. UPS internal temperature is too high. The UPS transfers to Bypass mode, allowing the UPS to cool. Turn off and unplug the UPS. Clear vents and remove any heat sources. Ensure the airflow around the UPS is not restricted. Wait at least five minutes and restart the UPS. If the condition persists, contact your Avaya service representative. Battery Service Site Wiring Fault (120V models only) Overtemperature Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C 61 TROUBLESHOOTING Alarm or Condition Overload Continuous audible alarm Self-Test Possible Cause Action Power requirements exceed UPS capacity (101–110% for 2 minutes or 111–150% for 30 seconds) or the load is defective. Turn off and unplug the UPS. Remove some of the equipment from the UPS. Wait at least five seconds until all LEDs are off and restart the UPS. You may need to obtain a larger capacity UPS. The self-test has not completed properly. Verify that the proper amount of load is applied to the UPS before starting the self-test: 50% load for 700 VA; 35% load for 1000 VA; 38% load for 1500 VA; or 25% load for 2000 VA. UPS fault condition. Save your work and turn off your equipment. Turn off and unplug the UPS. Contact your Avaya service representative. The alarm cannot be silenced. Obtaining Service The troubleshooting chart covers most of the difficulties you may encounter during normal operations. If you have any questions or problems with your UPS, call your Avaya service representative or the appropriate telephone number on the service label of your UPS. Please have the following information ready when you call: S Material code S Serial number S Version number (if available) S Date of failure or problem S Symptoms of failure or problem S Customer return address and contact information 62 Avayat S9RM UPS Site Preparation, Installation and Operator’s Manual S 05147387 Rev C *05147387C* 05147387 C