Preview only show first 10 pages with watermark. For full document please download

Awaiting Image Ul 12-6

   EMBED


Share

Transcript

UL 12-6 6V 12AH General UL12-6 Awaiting Image Terminal Type Container Material Rated Capacity Part Number: UL12-6 Length: 151 ± 2 mm (5.94 inches) Width: 51 ± 2 mm (2.01 inches) Container Height: 94 ± 2 mm (3.70 inches) Total Height (with terminal): 100 ± 2 mm (3.94 inches) Approx Weight: Approx 1.62kg (2.57lbs) Normal Voltage 6V Normal Capacity (20HR) 12AH Standard Terminal F1 Optional Terminal F2 Standard Option ABS Flame Retardant Option (FR) UL94:VO 12.0 AH/0.60A (20hr, 1.80V/cell, 25°C / 77°F) 11.16 AH/1.12A (10hr, 1.80V/cell, 25°C / 77°F) 10.2 AH/2.04A (5hr, 1.75V/cell, 25°C / 77°F) 9.2 AH/3.06A (3hr, 1.75V/cell, 25°C / 77°F) 7.54 AH/7.54A (1hr, 1.60V/cell, 25°C / 77°F) Max Discharge Current 180A (5s) Internal Resistance Approx 15mΩ Discharge Characteristics Operating Temp. Range Discharge: -15 ~ 50°C (5 ~ 122°F) Charge: 0 ~ 40°C (5 ~ 104°F) Storage: -15 ~ 40°C (5 ~ 104°F) Nominal Operating Temp. Range 25 ± 3°C (77 ± 5°F) Cycle Use Initial Charging Current less than 3.6A.Voltage Standby Use No limit on Initial Charging Current Voltage Capacity affected by Temperature 40°C (104°F) 103% 25°C (77°F) 100% 0°C (32°F) 86% Design Floating Life at 20°C 5 Years Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher temperatures the time interval will be shorter. Dimensions 6.35 [0.2 5] 151 51 16.5 1 94 1 100 1 3.2 [0.12 6] 0. 8 [0. 031] 4. 75 [0. 187] F1 Terminal 1 ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE 1 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ISO9001 Constant Current Discharge (Amperes) at 25°C (77°F) F.V/Time 5 min 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 22.9 17.5 14.5 12.6 9.72 7.16 6.03 3.57 2.79 2.27 1.85 1.61 1.30 1.08 0.594 1.80V/cell 30.7 22.4 17.6 14.9 11.5 8.33 6.76 3.90 3.00 2.42 1.99 1.72 1.37 1.12 0.600 1.75V/cell 34.6 24.6 19.2 16.0 11.9 8.64 7.07 4.04 3.06 2.48 2.04 1.77 1.40 1.15 0.606 1.70V/cell 38.1 26.9 20.5 16.8 12.4 8.99 7.29 4.14 3.15 2.54 2.09 1.81 1.42 1.17 0.617 1.65V/cell 42.0 29.0 21.8 17.8 13.1 9.21 7.46 4.20 3.28 2.63 2.15 1.85 1.44 1.19 0.625 1.60V/cell 46.3 31.5 23.3 19.0 13.8 9.60 7.54 4.38 3.38 2.71 2.22 1.89 1.45 1.21 0.629 Constant Power Discharge (Watts) at 25°C (77°F) F.V/Time 5 min 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 41.8 32.4 27.1 23.7 18.5 13.8 11.6 6.93 5.44 4.44 3.63 3.16 2.56 2.14 1.18 1.80V/cell 55.5 40.9 32.3 27.6 21.5 15.9 13.0 7.51 5.82 4.71 3.88 3.37 2.71 2.21 1.19 1.75V/cell 61.2 44.3 34.9 29.4 22.2 16.3 13.5 7.76 5.91 4.80 3.97 3.46 2.75 2.26 1.20 1.70V/cell 65.6 47.1 36.7 30.7 22.9 16.9 13.9 7.94 6.06 4.92 4.06 3.52 2.78 2.31 1.22 1.65V/cell 71.3 50.4 38.7 32.3 24.0 17.2 14.1 8.01 6.29 5.07 4.16 3.59 2.82 2.35 1.23 1.60V/cell 76.8 53.5 40.8 34.1 25.2 17.8 14.2 8.31 6.45 5.21 4.28 3.65 2.84 2.37 1.24 Discharge Characteristics Float Charging Characteristics 4V Battery (V) Charge Volume % Temperature:25°C(77°F) 4.33 Terminal Voltage (V) 4.00 120 110 100 90 80 70 60 50 40 30 20 10 0 3.66 0.4C 3.33 1C 3.00 2.67 3C 1 2 4 0.207C 0.093C 0.05C 0.628C 2C 6 8 10 20 40 60 2 Min 4 6 8 10 20 Charging Current (XCA) 0.10 CA -2.25 V/cell temperature 25°C 0.25 0.15 5.5 Charging Current 0 4 8 12 Life Expectancy (year) Capacity (%) 0. 2 C A 1.0 CA 3.0 CA 2.0 CA -10 0 10 20 30 40 20 68 50 30 86 200 400 Remaining Capacity (%) Capacity(%) 30% DOD Ambient Temperature: 25°C (77°F) 600 800 50 °C 122 °F 1000 250C 60 B 300C 40 C 0 40 A C 20 0 2 4 6 8 10 Storage Time (Months) 12 A No supplementary required (Carryout supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use. Optional charging way as below: 1. Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell. 2. Charged for above 20 hours at limited current 0.25CA and constant voltage 2.25Vcell. 3. Charged for 8 ~ 10 hours at limited current 0.05 CA. C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles 100C 80 0 0 40 104 100 80 0 40 Self Discharge Characteristics 100 20 36 1 120 40 32 2 Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 50% DOD 28 Battery Temperature Cycle Life in Relation to Depth of Discharge 100% DOD 24 Charging voltage: 2.25V/cell Temperature (°C) 60 20 10 8 6 5 4 3 0.5 0 -20 16 Effect of Temperature on Long Term Float Life A 0.05 C 0.1 CA 20 6.0 After 100% Discharge 0.05 Charging Time (hours) 120 40 6.5 After 50% Discharge 0.10 0 Temperature Effects in Relation to Battery Capacity 60 7.0 Charge Voltage (Constant 2.25v/cell) h 80 7.5 Charged Volume 0.20 Discharge Time 100 Charging Voltage (V) ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE 2 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ISO9001