Transcript
Signal Relays
AXICOM
IM - A/B Relay board-space 60mm2 n Slim line 10x6mm (0.39x0.24”) and low profile 5.65mm (0.222”) n Switching power 60W/62.5VA n Switching voltage 220VDC/250VAC n Switching current 2A n Bifurcated contacts n High mechanical shock resistance up to 300g functional and 500g survival n Minimum
IM_AB
Typical applications Telecommunication, access and transmission equipment, optical network terminals, modems, office and business equipment, consumer electronics, measurement and Test equipment, industrial control, medical equipment, automotive applications Approvals UL 508 File No. E 111441
AXICOMÊSignalÊRelays
IM Relay
Technical data of approved types on request
Contact Data Contact Data
U 108-98001 Rev. M
Contact data (continued)
Contact ratings, UL contact rating 220VDC, 0.24A, 60W AXICOMÊSignalÊRelays 125VDC, 0.24A, 30W 250VAC, 0.25A, 62.5VA IM Relay 125VAC, 0.5A, 62.5VA 30VDC, 2A, 60W IM-C Mechanical IM-Dendurance IM-E 108 operations Coil Operating Range
Max. DC Load Breaking Capacity Max. DC load breaking capacity
Coil Voltage [U/Unom]
Coil Voltage [U/Unom]
Contact arrangement 1 form A (1 NO) 1 formIM-A B (1 NC) IM-B Number of contacts and type 1ÊPoleÊbreak 1ÊPoleÊmake 1ÊPoleÊÊ 2ÊPoleÊbreak 2ÊPoleÊmake 220VDC, 250VAC Max. switching voltage changeover Rated current 2A Contact assembly BifurcatedÊcontacts Unom 2A Limiting continuous current Coil Data 3.4 50mW coil Contact material Palladium-ruthenium,Êgold-covered 3.2 Umax. 100mW coil Switching power 60W,2ÊA 62.5VA Magnetic system monostable, bistable Limiting continuous current 2ÊA 4ÊA 2ÊA 2ÊA 3 at max. ambient temperature Umax. at 2x1A PdRu Contact material Coil voltage range 1.5 to 24VDC Umax. at 0A 2.8 Maximum switching current 2ÊA 2ÊA 3ÊA Max. coil temperature 2ÊA 2ÊA 2.6 Au covered 125°C Maximum swichting voltage 2.4 Umax. at 0A 220ÊVdc Uop. min. twin contacts Contact style Thermal resistance <150K/W 2.2 250ÊVac Minimum switching voltage 100µV 2 Maximum switching capacity 60ÊW,Ê62.5ÊVA 1.8 <100mΩ at 10mA/20mV Initial contact resistance Coil versions, standard version, monostable, 1 coil Umax. at 2x2A Thermoelectric potential <Ê10ʵV 1.6 ThermoelectricMinimum potential <10µV Rated Operate Release Coil Rated coil switching voltage 1.4 100ʵV Coil 1.2 Unom. nominal coil voltage typ. 1ms, 3ms Operate time code voltage voltage voltage resistance power Urel. min. Initial contact resistance / < 100 max. mΩ < 100 mΩ NO < 100 mΩ < 50 mΩ < 50 mΩ 1 Release time measuring condition: 10 mA / 20 mV VDC VDC VDC Ω±10% mW 0.8 Electrical CC0 Contact category 0 Uop min. without diode in parallel typ. 1ms, max. 3ms 01 3.0 2.25 0.30 64 140 0.6 endurance (≤ 30 mV / ≥ 10 mA) min.Ê2.5ÊxÊ106Êoperations 0.4 with diode in parallel typ. 3ms, max. 5ms 02 4.5 3.38 0.45 Urel. min. 145 140 cable load open end min.Ê2.0ÊxÊ106Êoperations 0.2 typ. 1ms, max. 5ms Bounce time max. 03 5.0 0 3.75 0.50 178 140 Resistive load at 125 Vdc / 0.24 A - 30 W min.Ê5ÊxÊ105Êoperations -50 -40 -30 -20 9.00 1.20 -10 0 10 20 30 40 50 60 70 1029 140 80 90 10 0 1 10 12 0 Electrical endurance 06 12.0 at 220 Vdc / 0.27 A - 60 W min.Ê1ÊxÊ105Êoperations Ambient Temperature [°C] All figures are given for coil without pre-energization, at ambient temperature +23°C at contact application 0 at 250 Vac / 0.25 A - 62.5 min.Ê1ÊxÊ105Êoperations min.Ê5ÊxÊ105Êoperations (≤ 30mV / ≤VA10mA) min. 2.5x106 operations at 30 Vdc / 1 A - 30 W min.Ê1ÊxÊ105Êoperations 6 cable load open end Coil operating range, standard version at 30 Vdc / 2 A - 60 Wmin. 2.0x10 operations Mechanical 3.4 typ.Ê108Êoperations resistive, 125VDC / endurance 0.24A - 30W min. 5x105 operations 3.2 140mW coil UL contact 220 Vdc / 0.24 A - 60 W resistive, 220 VDC /ratings 0.27A - 60W min. 1x105 operations 3 200mW coil 125 Vdc / 0.24 A - 30 W 2.8 resistive, 250VAC / 0.25A - 62.5VA min. 1x105 operations Umax. at 2x1A 250 Vac / 0.25 A - 62.5 VA 2.6 125 Vac / 0.5 A - 62.5 VA resistive, 30VDC / 1A - 30W min. 5x105 operations 2.4 Umax. at 0A 30 Vdc / 2 A - 60 W resistive, 30VDC / 2A - 60W min. 1x105 operations 2.2 Umax. at 0A
2 1.8 1.6
Umax. at 2x2A
1.4 1.2
Unom. nominal coil voltage
1 0.8 0.6
Urel. min.
0.4 0.2 0
resistive load DC Voltage [Vdc]
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
90
100 110 120
DC current [A]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
12-2011, Rev. 1211 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Coil Voltage [U/Unom]
Ambient Temperature [°C]
3.4 3.2 3 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0
Umax. - 5%coil duty at 2x2A (100mW)
Umax. - 100% coil duty at 0A (100mW)
Umax.-5%coil duty at 0A(100mW) Umax.-5%coil duty at 0A (200mW)
Umax. - 100% coil duty at 0A (200mW)
Umax. -5% coil duty at 2x1A (100mW)
21 of 28 Unom. nominal coil voltage
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions -50 -40 -30 -20 -10 0 10 20
Usetproduct min. Datasheets, data, ‘Definitions’ secmW Latching tion, application100 notes and all specifications 200 mW Latching are subject to change. 30
40
50
60
70
80
Ambient Temperature [°C]
90 100 110 120 130 140
1
= =
=
=
Signal Relays
AXICOM
Terminal Assignment
IM - A/B Relay Relay(Continued) – top view
Non-Latching Type
Terminal Assignment Relay – top view
Non-Latching Type
Latching Type, 1 Coil
not energized condition reset condition Terminal assignment C not energized condition TOP view on relay high dielectric version Initial dielectric strength between open contacts 2500Vrms IM-A, 1 form B (NC) IM-B, 1 form A (NO) between contact and coil 3500Vrms Initial surgeAssignment withstand voltage Terminal between open contacts Terminal Assignment 3500V – top view and coil Relay between contact 4900V Relay – top view Initial insulation resistance Non-Latching Type Latching Type, 1 Coil 9Ω between insulated elements Non-Latching >10Type Latching Type, 1 Coil not energized condition reset condition Capacitance reset condition between open contacts not energized max.condition 1pF between contact and coil max. 2pF between adjacent contacts max. 2pF
Insulation
RF Data
Isolation at 100MHz/900MHz Insertion loss at 100MHz/900MHz Voltage standing wave ratio (VSWR) at 100MHz/900MHz
-37.0dB/-18.8dB -0.03dB/-0.33dB
All specifications subject to change. Consult Tyco Electronics for latest specifications. All specifications subject to change. Consult Tyco Electronics for latest
1.06/1.49
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Contacts are shown in reset refer to the Product Compliance Support Center at condition. Contact position might www.te.com/customersupport/rohssupportcenter change during transportation and must be reset before use. Ambient temperature -40°C to +85°C Dimensions 10 of 28 All specifications subject to change. Consult Tyco Electronics for latest specifications. Thermal resistance < 150K/W Electronics for latest specifications. 12 of 28 Category of environmental protection All specifications subject to change. Consult TycoTHT version Standard version IEC 61810 RT V - hermetically sealed Degree of protection IEC 60529 IP 67, immersion cleanable Vibration resistance (functional) 20g, 10 to 500Hz 50g Shock resistance (functional), half sinus 11ms Shock resistance (destructive), half sinus 0.5ms 500g max. 0.75g Weight Resistance to soldering heat THT IEC 60068-2-20 265°C/10s 108-98001 R 108-98001 Rev. M AXICOMÊSignalÊRelays AXICOMÊSignalÊRelays Resistance to soldering heat SMT IEC 60068-2-58 265°C/10s IM-A Relay 1 Pole / 1/ Form / SPST NC IM-A Relay 1 Pole Break / 1 Break Form B SPST B NC Moisture sensitive level, JEDEC J-Std-020D MSL3 not recommended Ultrasonic cleaning Gull wings SMT version IM-A Dimensions in mm Dimensions in mm IM-A Packaging/unit DimensionsDimensions THT version tube/50pcs., box/1000 pcs. SMT version reel/1000 pcs., box/1000 or 5000 pcs.THT Version THT Version SMT VersionSMT Version Standard Version Standard Version
0.75
0.75 5.65-0.2 3.2
5.65-0.2 3.2
0.4 5.4±0.15
10.0±0.08 6.0±0.08
0.4 5.4±0.15 5.08±0.1
Holelayout Layout Mounting HoleMounting LayoutPCB
0.4 5.08±0.1
6.0±0.0
5.65-0.2
10.0±0.08 6.0±0.08
10.0±0.08
IMÊTHT IMÊSMT IMÊTHT IMÊSMT Standard GullÊWings Standard GullÊWings mm inch mm inch mm inch mm inch 6.0±0.08 10.0±0.08 10.00ʱÊ0.08 0.393ʱÊ0.003 10.00ʱÊ0.08 0.393ʱÊ0.003 L 10.00ʱÊ0.08 L 0.393ʱÊ0.003 10.00ʱÊ0.08 0.393ʱÊ0.003 6.00ʱÊ0.08 0.236ʱÊ0.003 ÊÊ6.00ʱÊ0.08 0.236ʱÊ0.003 W 6.00ʱÊ0.08 W 0.236ʱÊ0.003 ÊÊ6.00ʱÊ0.08 0.236ʱÊ0.003 5.65ÊÐÊ0.20 0.222ÊÐÊ0.008 ÊÊ5.65ÊÐÊ0.20 0.222ÊÐÊ0.008 H 5.65ÊÐÊ0.20 H 0.222ÊÐÊ0.008 ÊÊ5.65ÊÐÊ0.20 0.222ÊÐÊ0.008 T 3.2 0.125 N/A N/A T 3.2 0.125 N/A T1 N/A N/A 7.50ʱÊ0.30 0.295ʱÊ0.011 T1 N/A N/A 7.50ʱÊ0.30 0.295ʱÊ0.011 0.4 5.08ʱÊ0.10 0.200ʱÊ0.004 5.08ʱÊ0.10 0.200ʱÊ0.004 T2 5.08ʱÊ0.10 T2 0.200ʱÊ0.004 5.08ʱÊ0.10 0.200ʱÊ0.004 5.4±0.15 3.20ʱÊ0.15 0.126ʱÊ0.006 3.20ʱÊ0.15 0.126ʱÊ0.006 D1 3.20ʱÊ0.15 D1 0.126ʱÊ0.006 3.20ʱÊ0.15 0.126ʱÊ0.006 Coplanarity ≤0.1mm 5.08±0.1 2.20ʱÊ0.15 0.087ʱÊ0.006 2.20ʱÊ0.15 0.087ʱÊ0.006 D2 2.20ʱÊ0.15 D2 0.087ʱÊ0.006 2.20ʱÊ0.15 0.087ʱÊ0.006 Tw 0.40 0.015 0.4 0.015 Tw 0.40 0.015 0.4 0.015 S 0.75 0.029 N/A N/A S 0.75 0.029 N/A
5.4±0.15 7.5±0.3
Coplanarity ≤0.1mm
5.08±0.
7.5±0.
Coplanarity ≤ 0.1mm Coplanarity ≤ 0.1mm
Solder Pad Layout Solder Pad Layout
TOP view on component side of PCB
View onto the component the PCB (top view) View onto the component the PCB (top view View onto the component side of the PCBside (topofview) View onto the component side of the PCBside (topofview)
THT mounting holes
2
12-2011, Rev. 1211 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
SMT - solder pads
Terminal Assignment Terminal Assignment Datasheets and product data is subject to the Datasheets and product specification Datasheets, product data, ‘Definitions’ secRelay –terms top view of the disclaimer and all chapters of according to IEC 61810-1 andRelay to be– used tion, application notes and all specifications top view the ‘Definitions’ only together with the ‘Definitions’ section. Non-Latching are subject to change. Type section, available at Non-Latching Type Latching Type,Latching 1 Coil Type, 1 Coil http://relays.te.com/definitions not energized condition not energized condition
reset conditionreset condition
AXICOMÊSignalÊRelays
Packing
Dimensions in
IMConditions Relay Recommended Soldering AXICOMÊSignalÊRelays Soldering conditions according IEC 60058-2-58 and Signal Relays IPC/JEDEC J-STD-020B Recommended Soldering Conditions
108-98001 Rev. M
AXICOM
IM Relay
AXICOMÊSignalÊRelays
Soldering conditions according IEC 60058-2-58 andRelay (Continued) IM - typical A/B Full line: 20-40sec IPC/JEDEC J-STD-020B Dottedline: processlimits
AXICOMÊSignalÊRelays
IM Relay
IM Relay
240°C Recommended Soldering Conditions
Processing 20-40sec Soldering conditions according Recommended soldering conditions 180°C
Temperature °C Temperature °C
IPC/JEDEC J-STD-020B 240°C
Temperature °C
100°C
Tube for THT version 50 relays per tube 1,000 relays per box
Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Time (s)
130°C 100°C
Tube for THT version 50 relays per tube, 1000 relays per box
forced cooling
Full line: typical Dottedline: processlimits forced cooling
20-40sec
130°C240°C
180°C
Packing Packing
Dottedline: processlimits
Soldering130°C conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B 100°C 180°C
Packing
line: typical and IECFull60058-2-58
forced cooling Time (s)
Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Vapor Phase Soldering:
Recommended Reflow Soldering Profile temperature/time profile (lead
and housing peak temperature)
Tube fo Tub 50 relay 50re r 1,000
Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Recommended Reflow Soldering Time (s) Profile
1,00
Tape and reel for SMT version 1000 relays per reel, 1000 or 5000 relays per box
Recommended Reflow Soldering Profile
Temperature °C
Temperature °C Temperature °C
Recommended reflow soldering profile
Tape and reel for SMT version 1,000 relays per reel 1,000 or 5,000 relays per box
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Time (s)
Reel Dimension
Time (s)- Reflow Profile Resistance to Soldering Heat Infrared Soldering: temperature/
Resistance to soldering heat - Reflow profile
time profile (lead and housing peak temperature)
Resistance to Soldering Heat - Reflow Profile
Resistance to Soldering Heat - Reflow Profile
Tape an 1,000 re Tap 1,000 o
Reel Dimension Infrared Soldering: Temperature/Time Profile and Housing Peak Temperature) Reel (Lead dimensions
1,00 1,00
Reel Dimension
Reel Dimension
Temperature °C
Temperature °C Temperature °C
Time (s)
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Time (s)
All specifications subject to change. Consult Tyco Electronics for latest specifications. Infrared Soldering: Temperature/Time
Profile (Lead and Housing Peak Temperature)
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Time (s)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Time (s)
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
All specifications subject to change. Consult Tyco Electronics for latest specifications. 25 of 28 All specifications subject to change. Consult Tyco Electronics for latest specifications.
All specifications subject to change. Consult Tyco Electronics for latest specifications. 12-2011, Rev. 1211 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
All specifications subject to change. Consult Tyco Electronics for latest specifications.
25 of 28 Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
3
25 of 28
Signal Relays
AXICOM
IM - A/B Relay (Continued)
Product code structure Type IM Signal Relays IM Series IMA/IMB Contact arrangement A 1 form B, 1 NC B 1 form A, 1 NO Coil Coil code: please refer to coil versions table Performance type Blank Standard version Terminals T THT - standard Packing S Tube
Product code
IM
Typical product code
Arrangement
B
03
G
R
C High Dielectric Version G SMT-gull wing R Reel
Perf. type
Coil
Coil type
Terminals
Part Number
IMA01CGR 1 form B, High dielectric 3VDC Monostable SMT gull wing 1462040-1 IMA01CTS 1 NC THT standard 1462040-5 IMA02CGR contact 4.5VDC SMT gull wing 1462040-2 IMA02CTS THT standard 1462040-6 IMA03CGR 5VDC SMT gull wing 1462040-3 IMA03CTS THT standard 1462040-7 IMA06CGR 12VDC SMT gull wing 1462040-4 IMA06CTS THT standard 1462040-8 IMB01CGR 1 form A, 3VDC SMT gull wing 1462041-1 IMB01CTS 1 NO THT standard 1462041-4 IMB02CGR contact 4.5VDC SMT gull wing 1462041-2 IMB02CTS THT standard 1462041-5 IMB03CGR 5VDC SMT gull wing 1462041-7 IMB03CTS THT standard 1462041-8 IMB04CGR 6VDC SMT gull wing 1462041-9 IMB06CGR 12VDC 1462041-3 IMB06CTS THT standard 1462041-6 IMB07CGR 24VDC SMT gull wing 1-1462041-3 IMB07CTS THT standard 1-1462041-4 IMB42CGR 4.5VDC Bistable SMT gull wing 1-1462041-6 IMB42CTS THT standard 1-1462041-5
4
12-2011, Rev. 1211 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.