Preview only show first 10 pages with watermark. For full document please download

Axicom P1 Relay V23026 Signal Relays

   EMBED


Share

Transcript

Signal Relays AXICOM P1 Relay V23026 n Directly triggerable with TTL standard modules as ALS, HCT & ACT line 13.5x7.85mm (0.531x0.309”) n Switching current 1 A n Bifurcated 1 form C (CO) contact n Immersion cleanable AXICOM n High sensitivity results in low nominal power Telecom-, Signal consumption, and RF Relays 65 to 130mW for monostable and 30 to 150mW for bistable (latching) n Initial surge withstand voltage P1 V23026 Relay 2.5kV (2/10μs) meets the Bellcore Requirement GR-1089 1.5kV (10/160μs) meets FCC Part 68 n Slim 108-98009 Rev. E P1_THTSMD Contact Data Typical applications Automotive CANtype bus, imobilizer, office equipment, measurement Number ofequipment, contacts and and control equipment, medical equipment, safety equipment Contact assembly Contact material Z 1 changeover contact Bifurcated contact Palladium nickel, gold-rhodium covered Approvals Limiting continuous current at max. ambient temperature UL 508 File No. E 111441 Technical data of approved types on request Maximum switching current Maximum swichting voltage Contact Data Contact arrangement 1 form C (CO) Maximum switching capacity Max. switching voltage 125VDC, 150VAC Rated current 1A Thermoelectric potential Limiting continuous current, 85°C 1A Initial contact resistance / measuring condition: 10 / 20 mV Breaking capacity max. see max. DC loadmA breaking capacity Contact material Palladium nickel, Electrical endurance at 12 V / 10 mA at 6 V / 100 mA gold-rhodium covered Contact style at 30 V / 1000 mA bifurcated contact Min. recommended contact load 10mA at 20mV Initial contact resistance ≤50mΩ at 10mA/20mV Mechanical Frequency of endurance operation without load 200 ops./s Operate/release time max. 2ms UL contact ratings Set/reset time max. 2ms Bounce time max. 3ms Electrical endurance at 12V/10mA typ. 50x106 operations at 6V/100mA typ. 10x106 operations at 30V/1000mA typ. 10x103 operations Contact ratings UL contact ratings 30VDC/1A 65VDC/0.46A 150VAC/0.46A Mechanical endurance typ. 109 operations Max. DC Load Breaking Capacity Max. DC load breaking capacity Coil Data 1A Magnetic system polarized Coil voltage range 3 to 24VDC 1A other coil voltages on request 125 Vdc Operative range, IEC 61810 see coil operative range 150 Vac Max. coil temperature 85°C Thermal resistance <130K/W 30 W, 60 VA Coil versions, THT, monostable < 100 µV Coil Rated Operate Release Coil Rated coil < 50 m code voltage voltage voltage resistance power VDC Ω ±10% mW 7 operations min. VDCmin. typ. 5 x 10VDC 006 3 137 66 typ. 1 x 107 2.25 operations 0.3 001 5 370 68 operations 0.5 typ. 1 x 104 3.75 005 9 6.75 0.9 1165 70 002 12 9.00 1.2 2250 34 typ. 109 operations 004 24 18.00 2.4 4500 128 All figures are given for coil without pre-energization, at ambient temperature +23°C. 30 Vdc / 1 A 65 Vdc / 0.46 A Coil versions, SMT, monostable / 0.46 A Release Coil Rated 150 Vac Operate Coil Rated coil code voltage voltage voltage AXICOM resistance power VDC VDCmin. VDC ΩRelays ±10% mW min. and RF Telecom-, Signal 026 3 2.25 0.3 113 80 021 5 3.75 P1 V23026 0.5 313 80 Relay 025 9 6.75 0.9 1015 80 022 12 9.00 1.2 1800 80 024 24 18.00 2.4 4500 128 Coil Operating Range All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil operative range, monostable DC coil Unom Coil Voltage [U/Unom] 65 mW 130 mW Umax. at 0 A Umax. at - 1 A Umax. at 0 A Umax. Uop. min. Urel. min. Unom. nominal coil voltage Uop. min. Urel. min. Ambient Temperature [°C] Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Umax. - 5 % coil duty at 1 A Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions [U/Unom] 02-2012, Rev. 0212 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company 65 mW Latching Datasheets, data, ‘Definitions’ sec32product mW Latching tion, application notes and all specifications are subject to change. Umax. - 100 % coil duty at 0 A 1 Signal Relays AXICOM P1 Relay V23026 (Continued) Coil data (continued) Insulation Data Coil versions, THT and SMT, bistable 2 coils Coil Rated Set Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω ±10% mW 106 3 2.25 2.25 130 69 101 5 3.75 3.75 390 64 105 9 6.75 6.75 1200 68 102 12 9.00 9.00 1500 96 241) All figures are given for coil without pre-energization, at ambient temperature +23°C. Coils I and II are identical. 1) A nominal voltage of 24VDC is feasible with a 12VDC coil with a series resistor (1500Ω) Initial dielectric strength between open contacts between contact and coil Initial surge withstand voltage between contact and coil Capacitance between open contacts between contact and coil Clearance/creepage between contact and coil between adjacent contacts RF Data Coil data (continued) AXICOM Isolation at 100MHz/900MHz Insertion loss at 100MHz/900MHz Voltage standing wave ratio (VSWR) at 100MHz/900MHz 500Vrms 1500Vrms 2500V max. 5pF max. 6pF 0.75mm 0.75mm -30.0dB/-18.0dB -0.12dB/-1.9dB Coil Voltage [U/Unom] 1.06/1.75 Coil versions, THT, bistable 1 coil Telecom-, Signal and RF Relays 108-98009 Rev. E Coil Rated Set Reset Coil Rated coil code voltage voltage voltage resistance power P1 V23026 Relay mW VDC VDC VDC Ω ±10% Other Data 056 3 2.25 -2.25 300 30 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 051 5 3.75 -3.75 740 34 refer to the Product Compliance Support Center at 057 9 6.75 -6.75 2160 38 www.te.com/customersupport/rohssupportcenter Coil Operating Range 052 12 9.00 -9.00 4500 32 Ambient temperature -40 to +85°C 054 24 18.00 -18.00 4500 128 U Category environmental protection, = ofNominal coil voltage nom IEC 61810 RT III - immersion cleanable 65 mW = resistance Upper limit of the operative range of 200 to 2000Hz Umax.Vibration (functional) 20g, 130 mW the coil voltage (limiting voltage) 40g, 10 to 200Hz Shock resistance (functional) Coil data (continued) when coils are continously energized Umax. at 0 A IEC 60068-2-27 (half sine) 50 g Lower limit of the operative range of Uop. min. max. atbistable 0A Umax. at - 1 A Terminal= type PCB terminals and SMT terminals Coil versions,USMT, 1 coil the coil voltage (reliable operate Weight max. 2g Coil Rated Set Reset Coil Rated coil Resistancevoltage) to soldering heat THT code voltage voltage voltage resistance power IEC 60068-2-20 265 °C/10s VDC VDC VDC Ω ±10% mW = Lower limit ofheat the SMT operative range of Urel. min. Resistance to soldering 051 5 3.75 -3.75 740 34 the coil voltage (reliable release see reflow profile IEC 60068-2-58 052 12 9.00 -9.00 4500 32 voltage)level, JEDEC J-Std-020D Moisture sensitive MSL3 A nominal voltage of 24V is feasible with a 12V coil with a series resitor (4500Ω) nom. nominal coil voltage Other coil voltagesUon request Washing not recommended All figures are given for coil without pre-energization, at ambient temperature +23°C. Ultrasonic cleaning possible Uop. min. Coils I and II are identical. Packaging unit Urel. min. THT 2000 pcs. SMT 2400 pcs. Coil operative range, Ambient bistable Temperature [°C] Umax upper limit of the operative range of the coil voltage (limiting voltage) when coils are 65 mW Latching 32 mW Latching Coil Voltage [U/Unom] Umax. - 5 % coil duty at 1 A Umax. - 100 % coil duty at 0 A Umax. - 5 % coil duty at 0A Unom. nominal coil voltage Uset min. Ambient Temperature [°C] continuously energized. Uop min lower limit of the operative range of the coil voltage (reliable operate voltage). Urel min lower limit of the operative range of the coil voltage (reliable release voltage). 2 02-2012, Rev. 0212 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 8.0-0.2 5.08±0.15 5.08±0.15 10.9-0.5 10.9-0.5 0.2-0.15 10.9-0.5 8.0-0.2 0.85±0.1 5.08±0.15 0.2-0.15 5.08±0.15 SMT version 13.4±0.1 13.4±0.1 0.429 0.429 –– 0.020 0.020 0.200 0.200 ±± 0.006 0.006 N/A N/A 0.033 AXICOM 0.033 ±± 0.004 0.004 –– 7.75±0.1 0.006 13.4±0.1 7.75±0.10.008 13.4±0.1 7.75±0.1 0.008 0.006 7.75±0.1 7.75±0.1 0.2-0.15 0.2-0.15 8.0-0.2 8.0-0.2 7.60±0.1 7.60±0.1 0.315 – 0.008 0.315 0.033 0.033– ± ±0.008 0.004 0.004 8.0-0.2 0.85±0.1 8.0-0.2 0.2-0.15 8.0-0.2 0.85±0.1 6.9-0.2 3.5-0.2 SMT SMT Version Version 13.4±0.1 13.4±0.1 5.08±0.15 Mounting hole Mounting layout hole Mounting layout hole layout 5.08±0.15 5.08±0.15 0.3±0.1 0.3±0.1 10.90 10.90 –– 0.50 0.50 5.08 5.08 ±± 0.15 0.15 N/A N/A 0.85 SMT SMTVersion Version 0.85 ±± 0.10 0.10 7.60±0.1 0.20 –– 0.15 13.4±0.1 0.20 0.15 0.85±0.1 0.85±0.1 6.9-0.2 6.9-0.2 0.3±0.1 5.08±0.15 8.00 – 0.20 8.00 0.20 0.85 0.85– ± ±0.10 0.10 N/A N/A SMT 0.20 Version SMT Version SMT0.008 Version N/A– –0.15 N/A 0.20 0.15 0.008 – –0.006 0.006 7.75±0.1 5.08±0.15 5.08±0.15 7.75±0.1 Solder pad layout Solder10.9-0.5 pad layout Solder pad layout 10.9-0.5 0.85±0.1 0.85±0.1 13.0±0.1 13.0±0.1 3.5-0.2 THT version 7.60±0.1 7.60±0.1 3.5-0.2 0.3±0.1 0.3±0.1 Dimensions 0.3±0.1 13.0±0.1 13.0±0.1 6.9-0.2 6.9-0.2 THT THT Version Version 6.9-0.2 3.5-0.2 6.9-0.2 3.5-0.2 3.5-0.2 3.5-0.2 0.3±0.1 H 6.90 –– 0.20 0.272 –– 0.008 HS1 6.90 0.20 0.272N/A 0.008 S1 N/A N/A N/A 0.138 – 0.008 T 3.50 – 0.20 THT Version THT Version THT Version 0.138N/A –N/A 0.008 TS2 3.50 – 0.20 N/A N/A S2 T1 N/A N/A T1 N/A N/A T2 5.08 0.200 T2 5.08 ±± 0.15 0.15 0.200 ±± 0.006 0.006 0.012 S 0.30 0.012 ±± 0.004 0.004 S 0.30 ±± 0.10 0.10 S1 N/A THT THTVersion Version N/A S1 N/A N/A 13.0±0.1 13.0±0.1 13.0±0.1 7.60±0.1 7.60±0.1 N/A N/A S2 N/A N/A S2 Solder Solderpad padlayout layout 5.08±0.15 5.08±0.15 5.08 5.08 View View onto onto the the component component side side of of the the PCB PCB (top view) (top view) 5.08 5.08 Solder pad SMT version Solder pad layout layout View View onto onto the the component component side side of of the the PCB PCB (top view) (top view) 5.08 5.08 5.08 TOP view on component side of PCB Mounting hole THT version Mounting hole layout layout 10.9-0.5 10.9-0.5 View Viewonto ontothe thecomponent componentside sideofofthe thePCB PCB (top (topview) view) 5.08 View Viewonto ontothe thecomponent componentside sideofofthe thePCB PCB (top (top view) view) PCB layout 5.08±0.15 5.08 Mounting Mountinghole holelayout layout 0.2-0.15 0.2-0.15 View onto theView component onto theside View component ofonto the the PCB side component of the PCB side of the PCB View onto theView component onto theside View component ofonto the the PCB side component of the PCB side of th (top view) (top view) (top view) (top view) (top view) 5.08±0.15 (top view) Relay – top view Relay – top view Relay – top view Contact release Contact or reset release condition, Contact or reset release coilcondition, polarity or reset tocoil set condition, polarity the relay tocoil setpolarity the relay to set the relay 5.08 5.08 5.08 5.08 Terminal assignment Terminal assignment Terminal assignment Terminal Terminalassignment assignment Latching type, Latching 1 coil type, Latching 1 Latching coil type, type, 1 coil Latching 2 coils type, Latching 2 coils type, 2 coils Non-latchingNon-latching type Non-latching type type Relay Relay – –top top view view Terminal assignment reset condition reset condition reset condition condition reset condition reset condition not release energized not condition energized not condition energized condition Contact Contact releaseoror reset reset condition, condition, coil coilpolarity polarity toto set setthe the relay relayreset Bistable version, 2 coils are shown Bistable version, 1 coil Monostable version Contacts Contacts in are Co sh reset condition reset condition condition Terminal assignment Terminalrest assignment reset condition. reset Both condition. res Latching Latchingtype, type,1 1coil coil Latching Latchingtype, type,2 2coils coils Non-latching Non-latchingtype type coils can be used coilseither can be use co Relay – top view Relay – top view reset reset condition condition reset reset condition condition as set or reset as coil. set or reset asc not notenergized energizedcondition condition Contact Contacts Contactsare areshown showninin Contact release release or or reset reset condition, condition, coil coil polarity polarity to to set set the the relay relay reset resetcondition. condition.Both Both Latching type, 11 coil Latching type, 22are coils Contacts shown in reset Non-latching type coils coils can can be be used used either either Latching type, coil Latching type, coils Non-latching type condition. Both coils can be used either as set or reset coil. as as set set or or reset reset coil. coil. reset reset not reset condition condition reset condition condition Contact position might change not energized energized condition condition Contacts during transportation and must be Contacts are are shown shown in in reset before use. reset condition. reset condition. Both Both 4 of 12 All specifications All subject specifications to change. All subject Consult specifications to change. Tyco Electronics subject Consult to change. Tyco for latest Electronics Consult specifications. Tyco for latest Electronics specifications. for latest specifications. coils coils can can be be used used either either as set or reset coil. as set or reset coil. AllAll specifications specifications subject subject toto change. change. Consult Consult Tyco Tyco Electronics Electronics forfor latest latest specifications. specifications. 4 4ofof1212 All specifications subject to change. Consult Tyco Electronics for latest specifications. All specifications subject to change. Consult Tyco Electronics for latest specifications. 44 of of 12 12 02-2012, Rev. 0212 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3 P1 V23026 Relay Recommended Soldering Conditions AXICOM Telecom-, Signal and RF Relays Soldering conditions according IEC 60058-2-58 Signaland Relays Recommended Soldering Conditions IPC/JEDEC J-STD-020B P1 V23026 Relay Packing P1 V23026 Relay 20 - 40 sec Processing 20 - 40 sec Soldering130 conditions according IEC 60058-2-58 and °C IPC/JEDEC J-STD-020B 180°C °C 100 20 - 40 sec 130 °C 240 °C 100 °C forced cooling AXICOM Telecom-, Signal and RF Relays P1 V23026 Relay P1 V23026 Relay Packing Packing Packing Tube for 40 relays 2‘000 re Tube for THT version 40 relays per tube, 2000 relays per box Full line: typical Dotted line: forced process limits cooling Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) 180 °C 130 °C forced cooling 100 °C 13.8±0.2 Resistance to soldering heat - Reflow profile Resistance to soldering heat - Reflow profile Vapor Phase Soldering: temperature/time profile (lead and housing peak temperature) Temperature °C Temperature °C Resistance to soldering heat - Reflow profile Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Vapor Phase Soldering: Temperature/Time Profile (Lead Housing Peak Temperature) Tape andand reel for SMT version 480 relays per reel, 2400 relays per box 11.6±0.2 13.8±0.2 Temperature °C Temperature °C Temperature °C Soldering conditions according Recommended soldering conditions IEC 180 240°C °C IPC/JEDEC J-STD-020B Full line: typical 60058-2-58 andlimits Dotted line: process AXICOM Telecom-, Signal and RF Relays Soldering conditions according IEC 60058-2-58 and V23026 (Continued) P1 Relay IPC/JEDEC J-STD-020B Full line: typical Dotted line: process limits Recommended Soldering Conditions 240 °C 108-98009 Rev. E AXICOM Resistance to soldering heat - Reflow profile Temperature °C Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) Time (s) Infrared Soldering: Temperature/Time Profile Reel dimension 11.6±0.2 Recommended reflow soldering profile Infrared Soldering: temperature/ time profile (lead and housing peak temperature) Recommended reflow soldering profile Recommended reflow soldering profile 11.6±0.2 (Lead and Housing Peak Temperature) Reel dimensions Infrared Soldering: Temperature/Time Profile Time (s) Temperature °C °C Temperature °C Temperature 13.8±0.2 Time (s) 13.8±0.2 11.6±0.2 Reel dimension Reel dimension (Lead and Housing Peak Temperature) Reel dimension Recommended reflow soldering profile All specifications subject to change. Consult Tyco Electronics for latest specifications. Time (s) Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) All specifications subject to change. Consult Tyco Electronics for latest specifications. Time (s) Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature) All specifications subject to change. Consult Tyco Electronics for latest specifications. Time (s) Infrared Soldering: Temperature/Time Profile (Lead andsubject Housing Peak Temperature) All specifications to change. Consult Tyco Electronics for latest specifications. All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 12 All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 12 4 02-2012, Rev. 0212 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions All specifications subject to change. Consult Tyco Electronics for latest specifications. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 9 of 12 Tape and 480 rela 2‘400 pe Signal Relays AXICOM P1 Relay V23026 (Continued) Product code structure Typical product code V23026 A1 002 B201 Type V23026 P1 Series Signal Relay Version A1 THT, monostable D1 SMT, monostable B1 THT, bistable (latching), 2 coils E1 SMT, bistable (latching), 2 coils C1 THT, bistable (latching), 1 coil F1 SMT, bistable (latching), 1 coil Coil Coil code: please refer to coil versions table Contacts B201 1 form C, 1 CO Product Code Version Coil V23026A1006B201 THT version monostable V23026A1001B201 V23026A1005B201 V23026A1002B201 V23026A1004B201 V23026B1106B201 bistable, 2 coils V23026B1101B201 V23026B1105B201 V23026B1102B201 V23026C1056B201 V23026C1051B201 V23026C1057B201 V23026C1052B201 V23026C1054B201 V23026D1026B201 SMT version monostable V23026D1021B201 V23026D1025B201 V23026D1022B201 V23026D1024B201 V23026E1106B201 bistable, 2 coils V23026E1101B201 V23026E1105B201 V23026E1102B201 V23026F1051B201 V23026F1052B201 02-2012, Rev. 0212 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Coil voltage 3VDC 5VDC 9VDC 12VDC 24VDC 3VDC 5VDC 9VDC 12VDC 3VDC 5VDC 9VDC 12VDC 24VDC 3VDC 5VDC 9VDC 12VDC 24VDC 3VDC 5VDC 9VDC 12VDC 9VDC 12VDC Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Part Number 1-1393774-7 1393774-1 1-1393774-5 1393774-8 1-1393774-2 1393775-3 3-1393774-4 1393775-2 3-1393774-5 2-1393774-6 2-1393774-0 2-1393774-7 2-1393774-1 2-1393774-4 1393776-8 1393776-3 1422015-9 1393776-4 1393776-7 1393777-3 1422015-6 1393777-2 1393776-9 1422015-8 4-1393774-3 Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 5