RF Signal Relays
AXICOM
HF3 Relay n Y-Design n Frequency
range DC to 3GHz n Impedance 50Ω or 75Ω n Small dimensions (14.6x7.2x10mm) n 1 form C contact (1 changeover contact) n Immersion cleanable n Low power consumption (≤140mW) Typical applications Cable modems and linecards/ CATV, Tabs, measurement and test equipment ATE, satellite / audio / video tuners, wireless base stations and antennas, switching boards Contact Data
Contact arrangement Max. switching voltage Rated current Limiting continuous current, 23°C Switching power Max. continuos RF-power, 23°C Contact material Minimum switching voltage Initial contact resistance Operate time Release time without diode in parallel with diode in parallel Bounce time Duration of set/reset pulse min. Mechanical endurance
Coil Data
Coil voltage range
1 form C, 1 CO 220VDC, 250VAC 2A 2A 60W, 62.5VA, 50W (2.5GHz) 50W (2.5GHz) Ag, Au covered 100µV <100mΩ at 10mA, 30mV typ. 3ms, max. 5ms typ. 2ms, max. 5ms typ. 4ms, max. 6ms typ. 1ms, max. 3ms 20ms 107 operations
3 to 24VDC
Coil Data (continued) Coil versions, bistable Coil Rated Set Limiting Reset Coil Rated coil code voltage voltage voltage voltage resistance power VDC VDC VDC VDC Ω±10% mW 50Ω version, bistable, 1 coil 71 3 2.25 9.20 -2.25 128 70 72 4.5 3.38 13.85 -3.38 289 70 73 5 3.75 15.30 -3.75 357 70 74 6 4.50 18.50 -4.50 514 70 75 9 6.75 27.70 -6.75 1157 70 76 12 9.00 37.00 -9.00 2057 70 77 24 18.00 74.00 -18.00 8228 70 50Ω version, bistable, 2 coils 91 3 2.25 6.50 2.25 64 140 92 4.5 3.38 9.80 3.38 145 140 93 5 3.75 10.90 3.75 178 140 94 6 4.50 13.00 4.50 257 140 95 9 6.75 19.60 6.75 574 140 96 12 9.00 26.10 9.00 1028 140 97 24 18.00 52.30 18.00 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil versions, monostable Coil Rated Operate Limiting Release Coil Rated coil code voltage voltage voltage voltage resistance power VDC VDC VDC VDC Ω±10% mW 50Ω version, monostable, 1 coil 51 3 2.25 6.50 0.30 64 140 52 4.5 3.38 9.80 0.45 145 140 53 5 3.75 10.90 0.50 178 140 54 6 4.50 13.00 0.60 257 140 55 9 6.75 19.60 0.90 574 140 56 12 9.00 26.10 1.20 1028 140 57 24 18.00 52.30 2.40 4114 140 75Ω version, monostable, 1 coil 01 3 2.25 6.50 0.30 64 140 02 4.5 3.38 9.80 0.45 145 140 03 5 3.75 10.90 0.50 178 140 04 6 4.50 13.00 0.60 257 140 05 9 6.75 19.60 0.90 574 140 06 12 9.00 26.10 1.20 1028 140 07 24 18.00 52.30 2.40 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil Data (continued) Coil versions, bistable Coil Rated Set Limiting Reset Coil Rated coil code voltage voltage voltage voltage resistance power VDC VDC VDC VDC Ω±10% mW 75Ω version, bistable, 1 coil 21 3 2.25 9.20 -2.25 128 70 22 4.5 3.38 13.85 -3.38 289 70 23 5 3.75 15.30 -3.75 357 70 24 6 4.50 18.50 -4.50 514 70 25 9 6.75 27.70 -6.75 1157 70 26 12 9.00 37.00 -9.00 2057 70 27 24 18.00 74.00 -18.00 8228 70 75Ω version, bistable, 2 coils 41 3 2.25 6.50 2.25 64 140 42 4.5 3.38 9.80 3.38 145 140 43 5 3.75 10.90 3.75 178 140 44 6 4.50 13.00 4.50 257 140 45 9 6.75 19.60 6.75 574 140 46 12 9.00 26.10 9.00 1028 140 47 24 18.00 52.30 18.00 4114 140 All figures are given for coil without pre-energization, at ambient temperature +23°C.
06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
1
Contacts in reset position. Contact position might change during transportation and must be reset before use.
RF Signal Relays
HF3 Relay (Continued)
Coil Operating Range 140 mW
70 mW
RF Data
Coil operating Range
Isolation 3.5 at 100MHz/900MHz 80dB/72dB 70 mW at 3GHz 45dB 3 Insertion loss Umax. at 0 A at 100MHz/900MHz 0.03dB/0.12dB 2.5 at 3GHz 0.35dB Voltage standing wave ratio (VSWR) 2 at 100MHz/900MHz/3GHz 1.05/1.20/1.20
140 mW
Coil Voltage [U/Unom]
Coil Voltage [U/Unom]
Umax. at 0 A
eset position. Contact pochange during transportat be reset before use. Unom. nominal coil voltage
Urel. min.
Ambient Temperature [°C]
Unom3.5= Umax. = 3
Coil Voltage [U/Unom]
Uop. min. = 2.5
2
Urel. min. = 1.5
1
80dB/72dB 40dB 0.03dB/0.12dB 0.40dB 1.05/1.20/1.40
1.5
Other Data 1 Unom. nominal coil voltage
Uop. min.
70 mW
AXICOM
Nominal coil voltage Upper limit of the operative range 70 mWof the coil voltage (limiting voltage) Lower limit of the operative of Umax. atrange 0A the coil voltage (reliable operate voltage) For latching relays Uset min. resp. Ureset min. Lower limit of the operative range of the coil voltage (reliable release voltage)
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content 0.5 refer to the Product Compliance Support Center at Uop. min. www.te.com/customersupport/rohssupportcenter 0 Ambient temperature -55°C to +85°C -55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75 85 95 105 115 125 135 Thermal resistance <165K/W Ambient Temperature [°C] Category of environmental protection IEC 61810 RT III - wash tight Degree of protection, IEC 60529 IP 67, immersion cleanable Vibration resistance (functional) 35g, 10 to 1000Hz Shock resistance (functional), half sinus 11ms 50g Shock resistance (destructive), half sinus 0.5ms 150g Terminal type SMT Weight max. 2.5g Resistance to soldering heat SMT Peak Value IEC 60068-2-58 265°C Moisture sensitive level, JEDEC J-Std-020D MSL3 Ultrasonic cleaning not recommended Packaging/unit reel/400 pcs., box/400 or 2000 pcs.
Unom. nominal coil voltage
All specifications subject to change. Consult Tyco Electronics for latest specifications. 0.5 Uop. min.
5 of 12
0 -55 -45 -35 -25 -15
-5
5
15 25 35
45 55 65 75 85 95 105 115 125 135
Ambient Temperature [°C]
Insulation Data
50Ω version
Initial dielectric strength between open contacts between contact and coil Initial surge withstand voltage between open contacts between contact and coil
min.
est specifications.
2
06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
75Ω version
600Vrms 1000Vrms 1000V 1500V
5 of 12
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
RF Signal Relays
AXICOM
HF3 Relay (Continued) Typical RF performance, 75Ω version
0
0
-20
-20 Isolation [dB]
Isolation [dB]
Typical RF performance, 50Ω version
-40 NO
-60
NC
-80
-40 -80
NC
-100
-100
-120
-120 0
500
1000
1500
2000
2500
3000
0
Frequency [Mhz]
Insertion-loss [dB]
0.0 NC
-0.2
NO
-0.3 -0.4 0
500
1000
1500
1000
1500
2000
2500
2000
2500
2000
2500
Typical RF performance, 75Ω version (continued) 0.1
0.1
-0.1
500
Frequency [Mhz]
Typical RF performance, 50Ω version (continued)
Insertion-loss [dB]
NO
-60
2000
2500
0.0
NO
-0.1
NC
-0.2 -0.3 -0.4
3000
0
Frequency [Mhz]
500
1000
1500
1.25
1.20
1.20
1.15
1.15
VSWR
VSWR
Frequency [Mhz] 1.25
1.10 NC 1.05 NO 500
1000
1500
2000
NO
1.05
1.00 0
NC
1.10
2500
3000
Frequency[Mhz]
1.00 0
500
1000
1500
Frequency[Mhz]
Terminal assignment TOP view on component side of PCB Monostable
Bistable, 1 coil
Bistable, 2 coils
+
set
-
-
reset
+
22 21 20 19 18 17 16 15 14 13 12
1
Contacts are shown in reset condition. Contact position might change during transportation and must be reset before use.
2
3
4
5
6
7
8
9
+
reset
-
-
set
+
10 11
HF3-PIN-
06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
3
RF Signal Relays
AXICOM
HF3 Relay (Continued) PCB layout TOP view on component side of PCB 50Ω version
75Ω version
THIS DRAWING IS A CONTROLLED DOCUMEN
HJ
REVISIONS
DIST
HJ Dimensions
P
LTR
DESCRIPTION
C D D1 D2
DATE
Printing Printing REVIESED PER eco-11-005150 50Ω version REVISED PER ECO-11-017072 (ECR-13-009645)
21JUL2009 09JUL2010 09JUL2010 14JUN2013
P
APVD LOC
HD HD HMR AK
DIST
HJ
-
LTR
P
C D
+0.1 14.6 D1 -0.1
A
DESCRIPTION
DATE
75Ω version
Printing REVISED PER ECO-11-005150 REVISED PER ECO-11-017072 (ECR-13-009645)
UKo UKo UKo
09JUL2010 +0.1 -0.1 25MAR2011
7.2
14JUN2013
7.2+0.1 -0.1
0.8 1.27+0.1 -0.1 5.08+0.1 -0.1
0.95
6.35+0.15 -0.15
C
mm DIN 7168-m
ES
5 (3/11)
-
5
6
7
8
CHK
16AUG2002
APVD
16AUG2002
HD 9121 HD 9121 PRODUCT SPEC
-
9 10 11
0.9
1.27
Relay housing 0.7
DRAWING ALIAS:
16AUG2002
MATERIAL
FINISH
-
-
A-A
SIZE
HF3-Relay 50 Dimensions CAGE CODE DRAWING NO
0.5
0.8
10+0.5 0
0.4
5.08+0.1 -0.1
XX = Relay type zz = nominal voltage YYWW = Date code NNNN = Lot number
mm
1.27
6.35+0.15 -0.15 0.5
5.08+0.1 -0.1 6.35+0.15 -0.15
TOLERANCES UNLESS OTHERWISE SPECIFIED:
0 PLC 1 PLC 2 PLC 3 PLC 4 PLCDIMENSIONS: ANGLES -
0.5 +0.1 -0.1
1.27
+0.15
6.35-0.15 16AUG2002
CHK
16AUG2002
HD 9121
mm
0 PLC 1 PLC 2 PLC 3 PLC RESTRICTED- TO 4 PLC ANGLES
DWN
UKo 9193 -
HD 9121
7.2
5
7
-
8
9 10 11
0.9 Relay housing 1 2 3 4 5 6 7 8 0.6
9 10 11
0.9
0.9 0.5
Relay housing
1.27 MATERIAL
-
A-A
FINISH
-
2.54
0.6
TE Connectivity NAME
SIZE 16AUG2002
HF3-Relay 75 Dimensions MATERIAL CAGE CODE DRAWING NO
A4
16AUG2002 00779
NAME
APPLICATION SPEC SIZE
A4
Datasheets andWEIGHT product- data is subject to the SCALE SHEET REV OF 1 according to IEC 61810-1 3:1 and to1 be used D2terms of the disclaimer and all chapters of CUSTOMER DRAWING the ‘Definitions’ section, available at only together with the ‘Definitions’ section. 1469-35 (3/11) http://relays.te.com/definitions
A-A
FINISH
-
RESTRICTED TO
1462050-2 SCALE
HD 9121
-
6
5
1.27
CUSTOMER DRAWING16AUG2002 APVD PRODUCT SPEC
-
4
16AUG2002
APPLICATION SPEC
WEIGHT CHK
TOLERANCES UNLESS OTHERWISE SPECIFIED:
3
2.54
5.08+0.1 -0.1
DWN
UKo 9193
2
0.5
5.08+0.1 -0.1
+0.1 -0.1
1
0.9
1.27+0.1 -0.1
+0.15 0.950.8 6.35-0.15
0.95
0.5
0.5 1.27+0.1 -0.1
7.2
0.8
DIMENSIONS:
-
0.5
22 21 20 19 18 17 16 15 14 13 12
DIN 7168-m
1462051-2 A4 00779Datasheets and product specification
0.7
0.95
22 21 20 19 18 17 16 15 14 13 12
1469-35 (3/11)
NAME
0.4 2.54+0.1 -0.1
0.8
XX = Relay type APVD HD 9121 zzDIN=7168-m nominal voltage PRODUCT SPEC YYWW = Date code H2000-DOK02 NNNN = Lot number
TE Connectivity
06-2015, Rev. 0615 CUSTOMER DRAWING www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company WEIGHT
4
2.54
DWN
1
3
0.9
6.35+0.15 -0.15
APPLICATION SPEC
4
2
0.9
5.08+0.1 -0.1
UKo 9193
TOLERANCES UNLESS OTHERWISE SPECIFIED:
7.2 1
XX = Relay type zz = nominal voltage YYWW = Date code NNNN = Lot number DIMENSIONS:
5
0.5
1.27+0.1 -0.1
THIS DRAWING IS UNPUBLISHED.
COPYRIGHT2005 BY TE Connectivity
0.8
6
10
22 21 20 19 18 17 16 15 14 13 12
0.5 0.5
0.95
6
0.9
0.5 2.54+0.1 -0.1
3.81+0.1 -0.1
0.9
0.7
0.5
5
0.95
0.4
-0.1
2.54+0.1 -0.1
14.6
0.9
+0.1 5.08 -0.1+0.1 3.81
10
0.8
5.08+0.1 -0.1
6
0.8
0.7
0.1 A
14.6
10
0.9
2.54+0.1 -0.1
COPYRIGHT2005 BY TE Connectivity THIS DRAWING IS UNPUBLISHED.
2.54+0.1 -0.1
5.08+0.1 -0.1
+0.1 +0.1 3.81 2.54 -0.1 -0.1
ALL RIGHTS RESERVED.
0.9
3.81+0.1 -0.1
9.4+0.2 -0.2
9.4+0.2 -0.2
C
3.81+0.1 -0.1
5.08+0.1 -0.1 3.81+0.1 -0.1
COPYRIGHT2005 BY TE Connectivity
14.6
5.08+0.1 -0.1
4.9 6.7
6.7 0.1 A
C
0.1 A
ALL RIGHTS RESERVED.
9.4
RELEASED FOR PUBLICATION
RELEASED FOR PUBLICATION
6.7 +0.2 -0.2
5.08+0.1 -0.1
0.9+0.1 -0.1
3° 2
3° 2005
10+0.5 0
2005
0.9+0.1 -0.1
2
3°
Coplanarity<=0.10mm
AP
HD HD HM AK
A
4.9
Coplanarity<=0.10mm Coplanarity<=0.10mm
UKo UKo UKo UKo
HD HMR A AK
2
14.6+0.1 -0.1
4.9
DWN
21JUL2009 Printing C THIS DRAWING IS A CONTROLLED DOCUMENT. 09JUL2010 Printing D REVISIONS 25MAR2011 REVISED PER ECO-11-005150 D1 LTR DESCRIPTION DATE DWN APVD 14JUN2013 D2PrintingREVISED PER ECO-11-017072 (ECR-13-009645) 21JUL2009 UKo HD
D2
7.2+0.1 -0.1
14.6+0.1 -0.1
DWN
UKo UKo RK UKo
-
10+0.5 0
THIS DRAWING IS A CONTROLLED DOCUMENT. LOC
REVISIONS
DIST
0.9+0.1 -0.1
LOC
3:1
-
SHEET
1
OF
1TE Connectivity D2 REV
HF3-Relay 75 Dimensions
RESTRICTED T
CAGE CODE DRAWING NO
Datasheets, data, ‘Definitions’ sec00779 product 1462050-2 tion, application notesSCALE and all specifications SHEET 1 3:1 are subject to change.
OF
1
REV
D
RF Signal Relays
AXICOM
HF3 Relay (Continued) Processing
Packing
Tape and reel for SMT
Resistance to soldering heat
Reel dimensions
Infrared soldering
Temperature [°C]
temperature/time profile (lead and housing peak temp.)
Time [s]
Recommended soldering conditions Vapour phase soldering 20 to 40s 240°C
full line: typical dotted line: process limits
Temperature [°C]
180°C 130°C external preheating 100°C
forced cooling
Vapour phase soldering temperature/time profile (lead and housing peak temp.)
Time [s]
06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
5
RF Signal Relays
AXICOM
HF3 Relay (Continued) Product code structure
Typical product code HF3 53
Type HF3 Signal Relays HF3 Series 1 form C, 1 CO Coil Coil code: please refer to coil versions table Performance type 5x 50Ω version, monostable 1coil 7x 50Ω version, bistable 1coil 9x 50Ω version, bistable 2coils
Product code
Arrangement
0x 2x 4x
75Ω version, monostable 1coil 75Ω version, bistable 1coil 75Ω version, bistable 2coils
Version
Coil
Coil type
Part number
HF3 51 1 form C (1 CO) 50ohm 3VDC Monostable 1462051-1 HF3 52 4.5VDC 1-1462051-6 HF3 53 5VDC 1462051-2 HF3 54 6VDC 1-1462051-7 HF3 55 9VDC 1462051-3 HF3 56 12VDC 1462051-4 HF3 57 24VDC 1462051-5 HF3 71 1 form C (1 CO) 50ohm 3VDC Bistable 1 coil 1462051-6 HF3 72 4.5VDC 1-1462051-8 HF3 73 5VDC 1462051-7 HF3 76 12VDC 1462051-9 HF3 91 1 form C (1 CO) 50ohm 3VDC Bistable 2 coils 1-1462051-1 HF3 92 4.5VDC 2-1462051-0 HF3 93 5VDC 1-1462051-2 HF3 95 9VDC 1-1462051-3 HF3 96 12VDC 1-1462051-4 HF3 97 24VDC 1-1462051-5 HF3 01 1 form C (1 CO) 75ohm 3VDC Monostable 1462050-1 HF3 02 4.5VDC 1-1462050-6 HF3 03 5VDC 1462050-2 HF3 06 12VDC 1462050-4 HF3 07 24VDC 1462050-5 HF3 21 1 form C (1 CO) 75ohm 3VDC Bistable 1 coil 1462050-6 HF3 23 5VDC 1462050-7 HF3 26 12VDC 1462050-9 HF3 41 1 form C (1 CO) 75ohm 3VDC Bistable 2 coils 1-1462050-1 HF3 43 5VDC 1-1462050-2 HF3 46 12VDC 1-1462050-4 HF3 47 24VDC 1-1462050-5 This list represents the most common types and does not show all variants covered by this data sheet. Other types on request
6
06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company