Transcript
General-Use Potentiometer Tuning
HPX
High Sensitivity over a Long Scanning Distance of 800mm (Thru Scan Model), Easy-to-Use Functions/Structure, and High Reliability.
Series
Quick response (50µs) plus mark detection. Self-diagnostic LEDs plus self-diagnostic output. Fine-tuning of sensitivity using multi-turn potentiometer with indicator.
Operation mode
Timer function
Outout mode
Self-diagnostic output
Supply voltage
Self-diagnostic indication
Shape
Stability indication
Model
Sensitivity ajustment
AMPLIFIER UNIT ORDER GUIDE
○
○
○
○
○
NPN open collector
HPX-H1
High sensitivity
HPX-H2
PNP open collector Low hysteresis
10 to 30Vdc
NPN open collector PNP open collector
Light ON/ Light ON, selectable
HPX-A1 ○
○
○
○
○ HPX-A2 HPX-F1
NPN open collector Fast detection
○ PNP open collector
1
Catalog listing
○
○
○
○ HPX-F2
アンプユニッ ト仕様 AMPLIFIER UNIT
SPECIFICATIONS
2
FIBER UNIT AND AMPLIFIER COMBINATIONS Thru scan Group
Appearance
3
Long distance
Scanning distance (mm)
Amp
Features
Cable length (cuttable)
Long scanning distance
Cut to length 2m
Bend radius
HPF-T001
11
Core: 1.4 dia. (1)
M4
3
Catalog listing
800
HPX-H HPX-A HPX-F
400 160
R20
HPF-T002
15
Core: 1.4 dia. (1)
3 dia. Lens 3
HPF-T003
11
Core: 1 dia. (1)
M4
Sleeve 1.2 dia.
Lens 3
R20
Standard
HPF-T004
15
Core: 1 dia. (1)
3 dia.
Sleeve 1.2 dia.
Standard
10
HPX-H HPX-A HPX-F
10 65 ± 4
15
400
Cut to length 2m
200 80
M4
Core: 1 dia. (1)
10
Sleeve (flexible)
HPF-T005 R10/R20
HPF-T006
10 65 ± 4
15
3 dia.
Core: 1 dia. (1)
9.5 13.5
Core: 1 dia. (1)
Standard diameter and compact
R20
HPF-T045
Static installation, flexible, and small diameter
R1
HPF-T024
M3 HPX-H HPX-A HPX-F
11
Core: 0.5 dia. (1)
50 25 12
M3 Lens 3 ± 0.3
Ultra bend tolerant
HPF-T025
11
Core: 1 dia. (1)
M4
HPX-H HPX-A HPX-F
Static installation, flexible, and standard model
300 150 60
Cut to length 2m
R2
HPF-T031
8
Core: 1 dia. (1)
3 dia.
15 ± 3
12
HPX-H HPX-A HPX-F
Sleeve 1 dia.
20 10 3
R1
HPF-T026
Elbow
R20
HPF-T010
R1
HPF-T028
R5
HPF-T028LF
2.5 dia. 3
11
5 5
Lens
15
10
Space saving
300
HPX-H HPX-A HPX-F
60
HPX-H HPX-A HPX-F
50 25 12
Static installation, flexible, small diameter, and flat top view model
HPX-H HPX-A HPX-F
80 40 12
Static installation, flexible, standard, and flat side view model
HPX-H HPX-A HPX-F
60 30 12
Small diameter sleeve
Cut to length 2m
R15
HPF-T007
HPX-H HPX-A HPX-F
20 10 3
Fine diameter sleeve
Cut to length 1m
R5
HPF-T037
Standard diameter
Cut to length 2m
R20
HPF-T042
Fine diameter
Cut to length 2m
R15
HPF-T015
150
M4
Core: 1 dia. (1)
10
Core: 0.5 dia. (1) Front view 15 10
15 ± 3
2-M3
10
Core: 1 dia. (1)
Cut to length 2m
Side view 3.3
5
1.75 light axis center
Static installation, flexible, and side view model
12
Sleeve 1 dia.
2.5 dia.
15
15
Side view Sleeve 0.88 dia.
2.5 dia.
35
HPX-H HPX-A HPX-F
240 120 48
3 dia. Sleeve 0.5 dia.
Small diameter
5±2
Core: 0.25 dia. (1)
15
3 dia.
HPX-H HPX-A HPX-F
12 6 2
3
Group
Appearance
Scanning distance (mm)
Amp HPX-H HPX-A HPX-F
6
Core: 0.25 dia. (1)
Features
12 6 2
Catalog listing
HPF-T038 Connector 0.5m
Sleeve 0.4 dia.
10
Bend radius
Fine diameter
1.0 dia.
5
Cable length (cuttable)
HPX-H HPX-A HPX-F
6 3
Fine diameter sleeve
HPX-H HPX-A HPX-F
12 6 2
Fine diameter sleeve
HPX-H HPX-A HPX-F
100 50 20
Small diameter
HPX-H HPX-A HPX-F
110 45
HPF-T039
Core: 0.125 dia. (1) Sleeve 0.4 dia.
Small diameter
60 ± 3
15
Core: 0.25 dia. (1)
R15
3 dia.
22
Core: 0.5 dia. (1)
Cut to length 2m
HPF-T043
2 dia.
11
Core: 0.75 dia. (1)
220
Small diameter and long scanning distance
HPF-T044
M3
HPF-T008
11
Core: 0.25 dia. (1)
M3
HPX-H HPX-A HPX-F
15
Elastic
HPF-T040
Core: 0.25 dia. (4)
100 40 20
Elastic small diameter
1.5 dia.
HPF-T009 Cut to length 2m
R4
HPF-T046
10
Core: 0.25 dia. (4)
1.5 dia.
Lens 3
11
Core: 0.25 dia. (16)
265
HPX-H HPX-A HPX-F
50
HPX-H HPX-A HPX-F
50
Elastic standard diameter
130
HPF-T033
M4
Lens 3
11
Core: 1 dia. (1)
To 105˚C
M4
1
Heat resistant
250 120
Core: 1.5 dia. (1)
400
R35
HPF-T017
200
To 150˚C
HPX-H HPX-A HPX-F
200 100 40
To 200˚C
Connector 1m
R15
HPF-T018
HPX-H HPX-A HPX-F
Heat and cold resistant from -60˚C to +350˚C
Connector 2m
R25
HPF-T014
50
80
M4
Lens 3
15
(10)
Glass fiber: 1 dia. (0.05 dia. x 320) (1)
M4
Lens 3
17 30
Glass fiber: 0.05 dia. (0.05 dia. x 370)
250 120
M4 (Lens incorporated)
17
1,500 HPX-H HPX-A HPX-F
11
750 300
Parallel beam top view
HPF-T019
M4
Narrow beam
HPF-T012
Cut to length 2m HPX-H HPX-A HPX-F
15 17
R25
1.3
R20 1,600
4.3
(Lens incorporated)
HPX-H HPX-A HPX-F
800 320
Parallel beam side view
Cut to length 2m
HPF-T020
4 dia. (Lens incorporated)
17
1,200 HPX-H HPX-A HPX-F
11
Narrow beam top view
600 240
R15
HPF-T023
R5
HPF-T030
M4
Mapping
(Lens incorporated)
Core: 1.5 dia. (1) 9
HPX-H HPX-A HPX-F
Narrow beam -1.5˚/+1.5˚max. side view
350 175 70
15
4
Cut to length 2m
Appearance
Amp 7.5 10 15
Group
7.5 8 15
HPX-H HPX-A HPX-F
Scanning distance (mm)
Features
250
Array
125
Bend radius
Catalog listing
R4
HPF-T021
50
38.3 14.5
1,200 HPX-H HPX-A HPX-F
15
240 Cut to length 2m
1,100
38.3 14.5
HPX-H HPX-A HPX-F
HPF-T021T
Beam 15mm wide
600
Wide beam 17
Cable length (cuttable)
Beam 15mm wide Side beam
550 200
R15
HPF-T021S
15
23
71.3
30
HPX-H HPX-A HPX-F
2,000 1,000 400
5
Beam 30mm wide
HPF-T021WT
Diffuse scan Group
Appearance
Scanning distance (mm)
Amp
Features
Cable length (cuttable)
Bend radius
Catalog listing
Long scanning distance
Cut to length 2m
R20
HPF-D001
Standard
Cut to length 2m
230
Long distance
HPX-H HPX-A HPX-F
3 20
Core: 1.4 dia. (2)
120 45
M6
HPF-D002
3 20
2.5 dia.
Standard
150
Core: 1 dia. (2)
M6 65 ± 4
20
HPX-H HPX-A HPX-F
80 30
R20
HPF-D003 Core: 1 dia. (2)
M6 HPX-H HPX-A HPX-F
11
Core: 0.5 dia. (2)
10 5 2
Small diameter
R1
HPF-D029
Standard
R2
HPF-D030
R10/R1
HPF-D031
Coaxial
R1/R4
HPF-D032
Standard diameter
R5
HPF-D044
R2
HPF-D045LF
M3
80
HPX-H HPX-A HPX-F
3 20
Core: 1 dia. (2)
40 15
M6
Sleeve 1.2 dia.
Ultra bend tolerant
40 ± 2
11
10
10
10
HPX-H HPX-A HPX-F
5 2
HPX-H HPX-A HPX-F
5
Lens 18
Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(4)
18 10
M3
30
80
HPX-H HPX-A HPX-F
15
HPX-H HPX-A HPX-F
For details, contact Yamatake Corporation.
40
3 dia.
Core: 1 dia. (2) 15 10
3.3 5
1.5 light axis center
10
Compact
Cut to length 2m
M4
Core: 0.5 dia. (2)
15
Small diameter sleeve (bendable)
2-M3
Core: 1 dia. (2)
Static installation, flexible, standard, and flat side-view model
Cut to length 2m
HPF-D004
11
Core: 0.5 dia. (2)
M3
Small diameter HPX-H HPX-A HPX-F
15
Core: 0.5 dia. (2)
40
HPF-D005
20 8
3 dia.
Cut to length 2m
Sleeve 1.2 dia. 65 ± 4
11
Small diameter sleeve
10
10
Core: 0.5 dia. (2)
Small diameter
HPF-D006
M4
15
Lens
Core: 0.75 dia. (2)
R15
Small diameter long scanning distance
80
HPX-H HPX-A HPX-F
40 15
HPF-D018
M4
Sleeve 0.82 dia. 15 ± 2
HPX-H HPX-A HPX-F
15
Core: 0.25 dia. (2)
4 2
Fine diameter sleeve
Cut to length 0.5m
HPF-D019
Small diameter sleeve
Cut to length 2m
HPF-D021
Fine diameter sleeve
Cut to length 0.5m
3 dia.
Sleeve 1.5 dia. 15 ± 2
HPX-H HPX-A HPX-F
10
Core: 0.5 dia. (2)
40 20 8
3 dia.
Sleeve 0.82 dia. 5±2
HPX-H HPX-A HPX-F
10
Core: 0.25 dia. (2)
4 2
R4
HPF-D039
R20
HPF-D009
R15
HPF-D010
2.5 dia.
150 3
Coaxial
HPX-H HPX-A HPX-F
20
Core: 1 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(16)
80
Cut to length 2m
Lens HPX-H HPX-A HPX-F
18
Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(4)
Coaxial
30
M6
40 20
Coaxial
8
M3
6
Group
Appearance
Scanning distance (mm)
Amp
Features
Cable length (cuttable)
Bend radius
Catalog listing
Connector 0.5m
R4
HPF-D034
Lens HPX-H HPX-A HPX-F
18 23
Core: 0.25 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(6)
25 13 5
M3 Lens
18
Coaxial
5
HPF-D035
Coaxial
Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9)
M3 Lens
50
HPX-H HPX-A HPX-F
25 10 Cut to length 2m
16
Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9)
R15
HPF-D038
M4
22 15
Sleeve 2 dia. Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9) 3 dia.
40
HPX-H HPX-A HPX-F
20 8
Small diameter coaxial
HPF-D042
Small diameter sleeve
HPF-D011
Sleeve 2 dia.
40 ± 4
15
3 dia.
Core: 0.5 dia. (2) Sleeve 2 dia. 15
15
HPX-H HPX-A HPX-F
15
R15
8 3
Small diameter short sleeve
Side view Core: 0.5 dia. (2)
Cut to length 2m
HPF-D041
2.8 dia.
35
HPX-H HPX-A HPX-F
50 32
R20
Standard diameter
12
HPF-D043
6 dia.
100
HPX-H HPX-A HPX-F
3 20
Core: 0.25 dia. (emitter core dia.)(16) Core: 0.25 dia. (receiver core dia.)(16)
50
10
Core: 0.25 dia. (emitter core dia.)(2) Core: 0.25 dia. (receiver core dia.)(2) 1.5 dia.
HPX-H HPX-A HPX-F
3
Connector 1m
Small diameter
Cut to length 2m
HPX-H HPX-A HPX-F
To 105˚C
Heat resistant
2
HPX-H HPX-A HPX-F
13 17
14
HPF-D037
80
To 150˚C
30
R25
HPF-D013
R35
HPF-D022
Cut to length 2m
150 3
HPF-D036
100 50 20
M6
Core: 1.5 dia. (2)
R4
M3
20
Core: 1 dia. (2)
Small diameter sleeve
HPF-D012
8 4
10
Core: 0.25 dia. (emitter core dia.)(2) Core: 0.25 dia. (receiver core dia.)(2)
Cut to length 2m
M6
6
Elastic
Standard
20
M6
HPF-D023
To 200˚C
10
M6
Glass fiber: 1.4 dia. Sleeve 2.1 dia.
HPX-H HPX-A HPX-F
50 50
Connector 1m
20
5 70
19
Glass fiber: 1.4 dia.
3
R15
Sleeve heat resistant to 200˚C
HPF-D024
M6
17 25
Glass fiber: 1.5 dia.
HPX-H HPX-A HPX-F
18
Heat and cold resistant from -60˚C to 350˚C
Cut to length 2m
R25
HPF-D015
HPX-H HPX-A HPX-F
20 20 12
Parallel beam reflection
Cut to length 2m
R15
HPF-D025
HPX-H HPX-A HPX-F
20
Array
Cut to length 2m
R4
HPF-D026
Limited reflection
Cut to length 2m
R15
HPF-D028
90 30
M6 (Built-in lens)
Parallel beam
(10.7)
20.5
1
15 10 13 20
12
(4.5)
Limited reflection
10
Wide beam
3
19
7
4
20
M5
HPX-H HPX-A HPX-F
100 50
2.5 ± 0.5 2.5 ± 0.5
7
2
Wet process Group
Appearance
Sensing type
Scanning distance (mm)
(Built-in lens) HPX-H HPX-A HPX-F
5 13.7
Core: 3 dia. (effective lens dia.)(1)
Features
Bend radius
Catalog listing
HPF-T029
750 300
4.7 dia. 14.8
Oil and chemicalproof
Cable length (cuttable)
1,500
PFA tube small diameter
5
HPX-H HPX-A HPX-F
340
R20 Cut to length 2m
170 70
HPF-T035
4.7 dia. HPX-H HPX-A HPX-F
16
Core: 1 dia. (2)
50 50 20
R20/R80
PFA tube
HPF-D014
6 dia.
Pipe-mounted. Light received when liquid present. 3 to 13mm dia. pipes.
28
Pipe-mounted. Light received when liquid absent. 8 to 19mm dia. pipes.
28
HPF-T032 Cut to length 5m
R4
HPF-T034
Liquid level Contact type. PFA tube 6mm dia.
20 (60)(Bending not allowed)
6 dia.
R25/R40
HPF-D027
R15/R30
HPF-D033
Cut to length 2m
Contact type. PFA tube 4mm dia.
15 (40)(Bending not allowed)
4 dia. 30.9 13
4
20
Liquid leak
Contact type
Cut to length 5m
R20
HPF-D040
Features
Cable length (cuttable)
Bend radius
Catalog listing
24
Vacuum Group
Appearance
Sensing type
Scanning distance (mm)
120
Lens
Thru scan
3
Glass fiber: 1.2 bundle dia. (1)
3
Diffuse scan
HPX-H HPX-A HPX-F
20 30
HPF-VT07
60 25
Heat resistant to 350˚C. Elbow connection
M4
20 35
Glass fiber: 1.7 bundle dia.
M6
HPX-H HPX-A HPX-F
2
10
R25
HPF-VD07
20 8
Heat resistant to 350˚C. Straight connection
3 20 35
Glass fiber: 1.7 bundle dia.
Connector 1m
35
HPF-VD09
M6
Air side (2 units)
10
Cut to length 2m
R20
HPF-VA01
Core: 1 dia. 8 6.8
1
7 2.5
(8)
22
Heat resistant to 200˚C. Light connector (2 units)
8
HPF-VJ03
2
EXTERNAL DIMENSIONS
(unit: mm)
Amplifier unit HPX-H, A, F (in common) When mounted on bracket (attached)
When mounted on DIN rail
1
9
2
OUTPUT CIRCUIT DIAGRAM
• NPN output type
• PNP output type
BASIC PRECAUTIONS
10