Preview only show first 10 pages with watermark. For full document please download

Azbil Hpx Series Specs

   EMBED


Share

Transcript

General-Use Potentiometer Tuning HPX High Sensitivity over a Long Scanning Distance of 800mm (Thru Scan Model), Easy-to-Use Functions/Structure, and High Reliability. Series Quick response (50µs) plus mark detection. Self-diagnostic LEDs plus self-diagnostic output. Fine-tuning of sensitivity using multi-turn potentiometer with indicator. Operation mode Timer function Outout mode Self-diagnostic output Supply voltage Self-diagnostic indication Shape Stability indication Model Sensitivity ajustment AMPLIFIER UNIT ORDER GUIDE ○ ○ ○ ○ ○ NPN open collector HPX-H1 High sensitivity HPX-H2 PNP open collector Low hysteresis 10 to 30Vdc NPN open collector PNP open collector Light ON/ Light ON, selectable HPX-A1 ○ ○ ○ ○ ○ HPX-A2 HPX-F1 NPN open collector Fast detection ○ PNP open collector 1 Catalog listing ○ ○ ○ ○ HPX-F2 アンプユニッ ト仕様 AMPLIFIER UNIT SPECIFICATIONS 2 FIBER UNIT AND AMPLIFIER COMBINATIONS Thru scan Group Appearance 3 Long distance Scanning distance (mm) Amp Features Cable length (cuttable) Long scanning distance Cut to length 2m Bend radius HPF-T001 11 Core: 1.4 dia. (1) M4 3 Catalog listing 800 HPX-H HPX-A HPX-F 400 160 R20 HPF-T002 15 Core: 1.4 dia. (1) 3 dia. Lens 3 HPF-T003 11 Core: 1 dia. (1) M4 Sleeve 1.2 dia. Lens 3 R20 Standard HPF-T004 15 Core: 1 dia. (1) 3 dia. Sleeve 1.2 dia. Standard 10 HPX-H HPX-A HPX-F 10 65 ± 4 15 400 Cut to length 2m 200 80 M4 Core: 1 dia. (1) 10 Sleeve (flexible) HPF-T005 R10/R20 HPF-T006 10 65 ± 4 15 3 dia. Core: 1 dia. (1) 9.5 13.5 Core: 1 dia. (1) Standard diameter and compact R20 HPF-T045 Static installation, flexible, and small diameter R1 HPF-T024 M3 HPX-H HPX-A HPX-F 11 Core: 0.5 dia. (1) 50 25 12 M3 Lens 3 ± 0.3 Ultra bend tolerant HPF-T025 11 Core: 1 dia. (1) M4 HPX-H HPX-A HPX-F Static installation, flexible, and standard model 300 150 60 Cut to length 2m R2 HPF-T031 8 Core: 1 dia. (1) 3 dia. 15 ± 3 12 HPX-H HPX-A HPX-F Sleeve 1 dia. 20 10 3 R1 HPF-T026 Elbow R20 HPF-T010 R1 HPF-T028 R5 HPF-T028LF 2.5 dia. 3 11 5 5 Lens 15 10 Space saving 300 HPX-H HPX-A HPX-F 60 HPX-H HPX-A HPX-F 50 25 12 Static installation, flexible, small diameter, and flat top view model HPX-H HPX-A HPX-F 80 40 12 Static installation, flexible, standard, and flat side view model HPX-H HPX-A HPX-F 60 30 12 Small diameter sleeve Cut to length 2m R15 HPF-T007 HPX-H HPX-A HPX-F 20 10 3 Fine diameter sleeve Cut to length 1m R5 HPF-T037 Standard diameter Cut to length 2m R20 HPF-T042 Fine diameter Cut to length 2m R15 HPF-T015 150 M4 Core: 1 dia. (1) 10 Core: 0.5 dia. (1) Front view 15 10 15 ± 3 2-M3 10 Core: 1 dia. (1) Cut to length 2m Side view 3.3 5 1.75 light axis center Static installation, flexible, and side view model 12 Sleeve 1 dia. 2.5 dia. 15 15 Side view Sleeve 0.88 dia. 2.5 dia. 35 HPX-H HPX-A HPX-F 240 120 48 3 dia. Sleeve 0.5 dia. Small diameter 5±2 Core: 0.25 dia. (1) 15 3 dia. HPX-H HPX-A HPX-F 12 6 2 3 Group Appearance Scanning distance (mm) Amp HPX-H HPX-A HPX-F 6 Core: 0.25 dia. (1) Features 12 6 2 Catalog listing HPF-T038 Connector 0.5m Sleeve 0.4 dia. 10 Bend radius Fine diameter 1.0 dia. 5 Cable length (cuttable) HPX-H HPX-A HPX-F 6 3 Fine diameter sleeve HPX-H HPX-A HPX-F 12 6 2 Fine diameter sleeve HPX-H HPX-A HPX-F 100 50 20 Small diameter HPX-H HPX-A HPX-F 110 45 HPF-T039 Core: 0.125 dia. (1) Sleeve 0.4 dia. Small diameter 60 ± 3 15 Core: 0.25 dia. (1) R15 3 dia. 22 Core: 0.5 dia. (1) Cut to length 2m HPF-T043 2 dia. 11 Core: 0.75 dia. (1) 220 Small diameter and long scanning distance HPF-T044 M3 HPF-T008 11 Core: 0.25 dia. (1) M3 HPX-H HPX-A HPX-F 15 Elastic HPF-T040 Core: 0.25 dia. (4) 100 40 20 Elastic small diameter 1.5 dia. HPF-T009 Cut to length 2m R4 HPF-T046 10 Core: 0.25 dia. (4) 1.5 dia. Lens 3 11 Core: 0.25 dia. (16) 265 HPX-H HPX-A HPX-F 50 HPX-H HPX-A HPX-F 50 Elastic standard diameter 130 HPF-T033 M4 Lens 3 11 Core: 1 dia. (1) To 105˚C M4 1 Heat resistant 250 120 Core: 1.5 dia. (1) 400 R35 HPF-T017 200 To 150˚C HPX-H HPX-A HPX-F 200 100 40 To 200˚C Connector 1m R15 HPF-T018 HPX-H HPX-A HPX-F Heat and cold resistant from -60˚C to +350˚C Connector 2m R25 HPF-T014 50 80 M4 Lens 3 15 (10) Glass fiber: 1 dia. (0.05 dia. x 320) (1) M4 Lens 3 17 30 Glass fiber: 0.05 dia. (0.05 dia. x 370) 250 120 M4 (Lens incorporated) 17 1,500 HPX-H HPX-A HPX-F 11 750 300 Parallel beam top view HPF-T019 M4 Narrow beam HPF-T012 Cut to length 2m HPX-H HPX-A HPX-F 15 17 R25 1.3 R20 1,600 4.3 (Lens incorporated) HPX-H HPX-A HPX-F 800 320 Parallel beam side view Cut to length 2m HPF-T020 4 dia. (Lens incorporated) 17 1,200 HPX-H HPX-A HPX-F 11 Narrow beam top view 600 240 R15 HPF-T023 R5 HPF-T030 M4 Mapping (Lens incorporated) Core: 1.5 dia. (1) 9 HPX-H HPX-A HPX-F Narrow beam -1.5˚/+1.5˚max. side view 350 175 70 15 4 Cut to length 2m Appearance Amp 7.5 10 15 Group 7.5 8 15 HPX-H HPX-A HPX-F Scanning distance (mm) Features 250 Array 125 Bend radius Catalog listing R4 HPF-T021 50 38.3 14.5 1,200 HPX-H HPX-A HPX-F 15 240 Cut to length 2m 1,100 38.3 14.5 HPX-H HPX-A HPX-F HPF-T021T Beam 15mm wide 600 Wide beam 17 Cable length (cuttable) Beam 15mm wide Side beam 550 200 R15 HPF-T021S 15 23 71.3 30 HPX-H HPX-A HPX-F 2,000 1,000 400 5 Beam 30mm wide HPF-T021WT Diffuse scan Group Appearance Scanning distance (mm) Amp Features Cable length (cuttable) Bend radius Catalog listing Long scanning distance Cut to length 2m R20 HPF-D001 Standard Cut to length 2m 230 Long distance HPX-H HPX-A HPX-F 3 20 Core: 1.4 dia. (2) 120 45 M6 HPF-D002 3 20 2.5 dia. Standard 150 Core: 1 dia. (2) M6 65 ± 4 20 HPX-H HPX-A HPX-F 80 30 R20 HPF-D003 Core: 1 dia. (2) M6 HPX-H HPX-A HPX-F 11 Core: 0.5 dia. (2) 10 5 2 Small diameter R1 HPF-D029 Standard R2 HPF-D030 R10/R1 HPF-D031 Coaxial R1/R4 HPF-D032 Standard diameter R5 HPF-D044 R2 HPF-D045LF M3 80 HPX-H HPX-A HPX-F 3 20 Core: 1 dia. (2) 40 15 M6 Sleeve 1.2 dia. Ultra bend tolerant 40 ± 2 11 10 10 10 HPX-H HPX-A HPX-F 5 2 HPX-H HPX-A HPX-F 5 Lens 18 Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(4) 18 10 M3 30 80 HPX-H HPX-A HPX-F 15 HPX-H HPX-A HPX-F For details, contact Yamatake Corporation. 40 3 dia. Core: 1 dia. (2) 15 10 3.3 5 1.5 light axis center 10 Compact Cut to length 2m M4 Core: 0.5 dia. (2) 15 Small diameter sleeve (bendable) 2-M3 Core: 1 dia. (2) Static installation, flexible, standard, and flat side-view model Cut to length 2m HPF-D004 11 Core: 0.5 dia. (2) M3 Small diameter HPX-H HPX-A HPX-F 15 Core: 0.5 dia. (2) 40 HPF-D005 20 8 3 dia. Cut to length 2m Sleeve 1.2 dia. 65 ± 4 11 Small diameter sleeve 10 10 Core: 0.5 dia. (2) Small diameter HPF-D006 M4 15 Lens Core: 0.75 dia. (2) R15 Small diameter long scanning distance 80 HPX-H HPX-A HPX-F 40 15 HPF-D018 M4 Sleeve 0.82 dia. 15 ± 2 HPX-H HPX-A HPX-F 15 Core: 0.25 dia. (2) 4 2 Fine diameter sleeve Cut to length 0.5m HPF-D019 Small diameter sleeve Cut to length 2m HPF-D021 Fine diameter sleeve Cut to length 0.5m 3 dia. Sleeve 1.5 dia. 15 ± 2 HPX-H HPX-A HPX-F 10 Core: 0.5 dia. (2) 40 20 8 3 dia. Sleeve 0.82 dia. 5±2 HPX-H HPX-A HPX-F 10 Core: 0.25 dia. (2) 4 2 R4 HPF-D039 R20 HPF-D009 R15 HPF-D010 2.5 dia. 150 3 Coaxial HPX-H HPX-A HPX-F 20 Core: 1 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(16) 80 Cut to length 2m Lens HPX-H HPX-A HPX-F 18 Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(4) Coaxial 30 M6 40 20 Coaxial 8 M3 6 Group Appearance Scanning distance (mm) Amp Features Cable length (cuttable) Bend radius Catalog listing Connector 0.5m R4 HPF-D034 Lens HPX-H HPX-A HPX-F 18 23 Core: 0.25 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(6) 25 13 5 M3 Lens 18 Coaxial 5 HPF-D035 Coaxial Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9) M3 Lens 50 HPX-H HPX-A HPX-F 25 10 Cut to length 2m 16 Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9) R15 HPF-D038 M4 22 15 Sleeve 2 dia. Core: 0.5 dia. (emitter core dia.)(1) Core: 0.25 dia. (receiver core dia.)(9) 3 dia. 40 HPX-H HPX-A HPX-F 20 8 Small diameter coaxial HPF-D042 Small diameter sleeve HPF-D011 Sleeve 2 dia. 40 ± 4 15 3 dia. Core: 0.5 dia. (2) Sleeve 2 dia. 15 15 HPX-H HPX-A HPX-F 15 R15 8 3 Small diameter short sleeve Side view Core: 0.5 dia. (2) Cut to length 2m HPF-D041 2.8 dia. 35 HPX-H HPX-A HPX-F 50 32 R20 Standard diameter 12 HPF-D043 6 dia. 100 HPX-H HPX-A HPX-F 3 20 Core: 0.25 dia. (emitter core dia.)(16) Core: 0.25 dia. (receiver core dia.)(16) 50 10 Core: 0.25 dia. (emitter core dia.)(2) Core: 0.25 dia. (receiver core dia.)(2) 1.5 dia. HPX-H HPX-A HPX-F 3 Connector 1m Small diameter Cut to length 2m HPX-H HPX-A HPX-F To 105˚C Heat resistant 2 HPX-H HPX-A HPX-F 13 17 14 HPF-D037 80 To 150˚C 30 R25 HPF-D013 R35 HPF-D022 Cut to length 2m 150 3 HPF-D036 100 50 20 M6 Core: 1.5 dia. (2) R4 M3 20 Core: 1 dia. (2) Small diameter sleeve HPF-D012 8 4 10 Core: 0.25 dia. (emitter core dia.)(2) Core: 0.25 dia. (receiver core dia.)(2) Cut to length 2m M6 6 Elastic Standard 20 M6 HPF-D023 To 200˚C 10 M6 Glass fiber: 1.4 dia. Sleeve 2.1 dia. HPX-H HPX-A HPX-F 50 50 Connector 1m 20 5 70 19 Glass fiber: 1.4 dia. 3 R15 Sleeve heat resistant to 200˚C HPF-D024 M6 17 25 Glass fiber: 1.5 dia. HPX-H HPX-A HPX-F 18 Heat and cold resistant from -60˚C to 350˚C Cut to length 2m R25 HPF-D015 HPX-H HPX-A HPX-F 20 20 12 Parallel beam reflection Cut to length 2m R15 HPF-D025 HPX-H HPX-A HPX-F 20 Array Cut to length 2m R4 HPF-D026 Limited reflection Cut to length 2m R15 HPF-D028 90 30 M6 (Built-in lens) Parallel beam (10.7) 20.5 1 15 10 13 20 12 (4.5) Limited reflection 10 Wide beam 3 19 7 4 20 M5 HPX-H HPX-A HPX-F 100 50 2.5 ± 0.5 2.5 ± 0.5 7 2 Wet process Group Appearance Sensing type Scanning distance (mm) (Built-in lens) HPX-H HPX-A HPX-F 5 13.7 Core: 3 dia. (effective lens dia.)(1) Features Bend radius Catalog listing HPF-T029 750 300 4.7 dia. 14.8 Oil and chemicalproof Cable length (cuttable) 1,500 PFA tube small diameter 5 HPX-H HPX-A HPX-F 340 R20 Cut to length 2m 170 70 HPF-T035 4.7 dia. HPX-H HPX-A HPX-F 16 Core: 1 dia. (2) 50 50 20 R20/R80 PFA tube HPF-D014 6 dia. Pipe-mounted. Light received when liquid present. 3 to 13mm dia. pipes. 28 Pipe-mounted. Light received when liquid absent. 8 to 19mm dia. pipes. 28 HPF-T032 Cut to length 5m R4 HPF-T034 Liquid level Contact type. PFA tube 6mm dia. 20 (60)(Bending not allowed) 6 dia. R25/R40 HPF-D027 R15/R30 HPF-D033 Cut to length 2m Contact type. PFA tube 4mm dia. 15 (40)(Bending not allowed) 4 dia. 30.9 13 4 20 Liquid leak Contact type Cut to length 5m R20 HPF-D040 Features Cable length (cuttable) Bend radius Catalog listing 24 Vacuum Group Appearance Sensing type Scanning distance (mm) 120 Lens Thru scan 3 Glass fiber: 1.2 bundle dia. (1) 3 Diffuse scan HPX-H HPX-A HPX-F 20 30 HPF-VT07 60 25 Heat resistant to 350˚C. Elbow connection M4 20 35 Glass fiber: 1.7 bundle dia. M6 HPX-H HPX-A HPX-F 2 10 R25 HPF-VD07 20 8 Heat resistant to 350˚C. Straight connection 3 20 35 Glass fiber: 1.7 bundle dia. Connector 1m 35 HPF-VD09 M6 Air side (2 units) 10 Cut to length 2m R20 HPF-VA01 Core: 1 dia. 8 6.8 1 7 2.5 (8) 22 Heat resistant to 200˚C. Light connector (2 units) 8 HPF-VJ03 2 EXTERNAL DIMENSIONS (unit: mm) Amplifier unit HPX-H, A, F (in common) When mounted on bracket (attached) When mounted on DIN rail 1 9 2 OUTPUT CIRCUIT DIAGRAM • NPN output type • PNP output type BASIC PRECAUTIONS 10