Preview only show first 10 pages with watermark. For full document please download

Barco Projection Systems

   EMBED


Share

Transcript

BARCO PROJECTION SYSTEMS QLD(1.5-2:1) Kit R9840130 INSTALLATION MANUAL LENS QGD(1.5-2.0:1) FOR ELM SERIES Date : 151099 Rev : 0 Art. No. : R5976087 QLD(1.5-2.0:1) Lens R9840130 What has to be done This new lens has to be installed on an ELM series projector Necessary Tools no tool necessary Installing the Lens To install the lens, follow the next procedure or look into the owner’s manual : Step Lens Formula Action 1 Switch on the projector. 2 Push 3x on the HELP key. 3 Push the é key to open the lens bridge (motor part of the lens housing). 4 Take the lens out of its packing material and remove the lens covers. 5 Turn the lens into the lens holder by turning clockwise. 6 Push the ê key to close the lens bridge. 7 Press EXIT to return to operational mode. To calculate the distance between the projector frontside (metal plate) and the screen (PD) for a given screen width (SW), use the following formula for BarcoELM G10 : Metric system (PD and SW in meter) : PDmin = 1.91 x SW - 0.05 PDmax = 2.56 x SW - 0.07 Inch system (PD and SW in inch) : PDmin = 1.91 x SW - 1.97 PDmax = 2.56 x SW - 2.76 BarcoELM R12 : Metric system (PD and SW in meter) : PDmin = 1.53 x SW - 0.05 PDmax = 2.05 x SW - 0.07 Inch system (PD and SW in inch) : PDmin = 1.53 x SW - 1.97 PDmax = 2.05 x SW - 2.76 To be continued on next page. BARCO ——————————————————— 1 ————————————— Projection Systems QLD(1.5-2.0:1) Lens R9840130 (Continued) Lens Cleaning Procedure To minimize the possibility of damaging the optical coating or scratching exposed lens surface, we have developed recommendations for cleaning the lens. FIRST, we recommend you try to remove any material from the lens by blowing it off with clean, dry deionized air. DO NOT use any liquid to clean the lenses. A TorayseeTM cloth is included with the lens kit. Proceed as follows : Step Toraysee Cloth Order Number Action 1 Always wipe lenses with a CLEAN TorayseeTM cloth. 2 Always wipe lenses in a single direction. Do not wipe back and forwards across the lens surface as this tends to grind dirt into the coating. 3 Do not leave cleaning cloth in either an open room or lab coat pocket, as doing so can contaminate the cloth. 5 If smears occur when cleaning lenses, replace the cloth. Smears are the first indication of a dirty cloth. 5 Do not use fabric softener when washing the cleaning cloth or softener sheets when drying the cloth. 6 Do not use liquid cleaners on the cloth as doing so will contaminate the cloth. Order number for a new TorayseeTM cloth : R379058. BARCO ——————————————————— 2 ————————————— Projection Systems