Transcript
BEST IDEAS FOR IP INTERCOM SOLUTIONS
Многоабонентская вызывная панель
BAS-IP AA-03/AA-05
Setting and operation manual
Note For the correct installation, follow the instructions. If you have any difficulty with installation and operation, please contact your dealer for advice. The technical parameters and specifications mentioned here may vary slightly from those stated in the instructions of the devices. This is our company conducts constant upgrading and improvement of the functionality to improve the characteristics of current devices.
2
CONTENT Individual outdoor panels Appearance ............................................................................................................... 4 Main functions .......................................................................................................... 4 Technical parameters ............................................................................................ 5 Equipment ................................................................................................................. 6 Setting through WEB interface ......................................................................... 6 Connection scheme ............................................................................................... 11 Mounting .................................................................................................................... 14 Multi apartment outdoor panels Appearance ............................................................................................................... Connection ................................................................................................................ Equipment ................................................................................................................. Setting through WEB interface ......................................................................... Connection scheme ............................................................................................... Mounting ....................................................................................................................
16 17 17 18 25 28
Internal monitors Appearance ............................................................................................................... 29 Main functions .......................................................................................................... 30 Technical parameters ............................................................................................ 30 Setting through WEB interface ......................................................................... 31 Connection scheme ............................................................................................... 38 Installation ................................................................................................................. 39 Concierge monitor Appearance ............................................................................................................... 40 Main functions .......................................................................................................... 41 Technical parameters ............................................................................................. 41 Configuration via the monitor’s graphic interface ...................................... 42 Setting through WEB interface ......................................................................... 47 Connection scheme ................................................................................................ 51 Appearance ............................................................................................................... 52 Main functions .......................................................................................................... 53 Technical parameters ............................................................................................ 53 Configuration via the monitor’s graphic interface ...................................... 54 Notes ............................................................................................................................ 57
3
APPEARANCE
Model AV-01 (v2.0 and v3.0 SIP)
Model AV-01T (v2.0 and v3.0 SIP) LIGHT SENSOR
LIGHT SENSOR MICROPHONE
BACKLIGHT
CAMERA
MICROPHONE
BACKLIGHT
CAMERA READER FOR CONTACTLESS CARDS
SIGN WITH THE NUMBER
RING BUTTON
LOUDSPEAKER
SIGN WITH THE NUMBER
RING BUTTON
LOUDSPEAKER
Model: AV-02 v3.0 SIP
Model: AV-02FP
LIGHT SENSOR
LIGHT SENSOR
IN A FIRE BACKLIGHT
LIGHT SENSOR CAMERA
PRESS TO COMMUNICATE WITH A DISPATCHER
RING BUTTON
MICROPHONE
4
RING BUTTON
MICROPHONE
MAIN FUNCTIONS Interface
Authentication
WEB-interface
WEB-interface
Lock opening
Talking mode
By card, with the monitor
Double-sided
Access control
Talking time
Reader for contactless cards
Up to 240 seconds
EM-Marin or MIFARE
Additional functions
Integration with ACS
SIP P2P
Output WIEGAND-26
Place for the signature near the call
Buttons for quick dialing 1 call button Number of ringtones
button Stores up to 10,000 cards Recording cards available through software or using master card
4 polyphonic ringtones
TECHNICAL PARAMETERS Panel type
Protection class
Individual
IP65
Screen
Operating temperature
No
-40 – +65 °C
Camera
Power consumption
1/3”, adjustment of the camera
5,5 W, in standby – 2,5 W
direction
Power
Angle
+ 12 V
71° horizontal × 56° vertical
Body
Resolution
Metal
800 TVL
Colors
Output video
Titanium-grey
D1 (704×576), H.264 Main Profile,
Dimensions for installation
BaseLine Profile
180×104×60 mm
Night backlight
Dimensions of panel
6 LEDs
192×116×45 мм
Light sensitivity 0,01 lux
Installation Flush mount, wall mount
5
EQUIPMENT Model
Model KEY
MOUNTING SCREWS
PROTECTIVE COVER
WATERPROOF CAP AND PROTECTIVE CABLE COVER 1
KEY
PROTECTIVE CABLE COVER 2
PROTECTIVE CABLE COVER 1
PROTECTIVE CABLE COVER 2 WATERPROOF CAP AND PROTECTIVE CABLE COVER 1 PROTECTIVE CABLE COVER 3
MOUNTING SCREWS
PROTECTIVE CABLE COVER 3
SETTING THROUGH WEB INTERFACE Search for the IP-address of the outdoor panel. After you have connected the outdoor panel in the same local area network as your computer, run the program «Upgrade Tool» to determine the IP-address of the outdoor panel.
Press the button and the program window will display the IP-address of the outdoor panel and any other devices BAS-IP, which are connected to the local network.
SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it sing a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings. In the Internet browser in the address bar enter the IP-address of the outdoor panel, and then enter your username and password. The username to enter the settings: admin. The password required for entry must match the password for access to the outdoor panel settings and is an installer’s password, default: 123456. 1. Network Settings. Select «Network» to access the network configuration settings:
2. Device Settings. Select «Device» to access the configuration of the Logical address, the operating mode and ringtones:
7
SETTING THROUGH WEB INTERFACE BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number. Panel mode: Set the operating mode «Personal Panel». The number of the building, entrance, floor, and apartment must match the address of the internal monitor, which will receive a call from this outdoor panel. If you have several outdoor panels that have one logical address, then in the “No” field, enter a value of 2, 3, 4, 5 and so on, until 9. If the logical address of the outdoor panel corresponds to the logical address of the monitor, and the IP addresses of the devices are in the same network segment – the devices will find each other, and the call will occur correctly. 3. Registration of contactless cards via WEB-interface. Enter in the “Master-card” number 0, and then click “Apply”. Within 20 seconds, bring the required registration master card to the area of the outdoor panel’s reader – an alarm sounds ”BEEP”, which means that the master-card has been registered successfully. Now, each user card can be brought to the panel’s reader. After each user card, ”BEEP” will sound which indicates a successful registration of the card. The time between adding cards should not exceed 10 seconds. 4. SIP settings. Select «VOIP» for the transition to SIP account settings:
8
SETTING THROUGH WEB INTERFACE Proxy: SIP-server address. It can be specified as the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: The domain address of the SIP-server is often the same as the IP address of the SIP-server. Password: Enter the password for the SIP-account (SIP-number). Stun IP and Stun Port: indicates if this outdoor panel is mounted after NAT, for example, a router. Username: indicated directly SIP-account (SIP-number). 5. Making calls. Select «Forward» to go to the next interface.
This section is used to forward calls received at the internal monitors when the monitor is not available or if it is disabled on any given SIP-number. 1. “RoomNo” field – enter the number of the apartment (floor + room) after calling on which the call forwarding will occur. For example, if the floor = 1 and the apartment = 1 you must enter the field 0101. 2. “SIP-account” field – enter the required SIP-number to which the call will come from the outdoor panel when dialing the appropriate apartment. Since 2015, the functionality of P2P SIP calls, which allows you to make calls to SIP-clients within the local network without SIP PBX was added to the software of outdoor panels. So that the outdoor panel can make a call to a SIP-client for P2P networks, you need to enter the number of apartments (floor + room) in the ”RoomNo” field, after calling on which the call forwarding will occur, and in the “Account” field the number like «sip:
[email protected] », where 101 – is desired number to display, 192.168.1.223 – IP address SIP client (if using softphone – IP address of the device on which the softphone is installed). The device on which the call is forwarding must have a static IP address on the network.
9
SETTING THROUGH WEB INTERFACE Getting streaming video via RTSP: To display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, it is necessary to address the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where the address – is the IP-address of the current outdoor panel. The panel will then request a username and password (the default username: admin, password: 123456). You can just enter this username and password into the initialization string before the address, then the string of the receiving streaming video will look like the following example: rtsp://admin:
[email protected]:8554/ch01
10
CONNECTION SCHEME Connection by an external power supply (AV-01 and AV-01T) NETWORK SWITCH ONLY GND
Black
Data 1 Red Data 0 Yellow
“EXIT“ BUTTON
.
.
+12 V
GND
NO NC
OUTDOOR PANEL
COM
V
“EXIT“ CONTACT 1
“EXIT“ CONTACT 2
CAT 5e
LOCK
POWER SUPPLY
Connection by an uninterruptible power supply (AV-01 and AV-01T) NETWORK SWITCH ONLY GND
Black
Data 1 Red
Yellow
“EXIT“ CONTACT 2
“EXIT“ BUTTON
V
CAT 5e
“EXIT“ CONTACT 1
Data 0
+12V GND POWER SUPPLY ATTENTION: THE LOCK OPENING TIME IS SET BY ADJUSTING THE RESISTOR ON THE DELAY MODULE BOARD SH-40.
.
COM
.
LOCK
NO NC
OUTDOOR PANEL
SGND CTRL
V PGND
lock lock
DELAY MODULE
11
CONNECTION SCHEME Connection by an uninterruptible power supply (AV-01 and AV-01T) NETWORK SWITCH
ONLY GND
Black
Data 1 Red
Yellow
“EXIT“ BUTTON
V
“EXIT“ CONTACT 1
CAT 5e
“EXIT“ CONTACT 2
Data 0
GND +18 V CTRL
NO
.
+12 V
COM
OUTDOOR PANEL
LOCK 1
LOCK
LOCK 2
UPS DP/P
NETWORK SWITCH
CAT 5e
485485+ GND
NO NC
OUTDOOR PANEL
COM
V
V+
+12 V
GND
12
POWER SUPPLY
LOCK
CONNECTION SCHEME Connection by an uninterruptible power supply (AV-01 and AV-01T) NETWORK SWITCH
CAT 5e
485485+ GND
V
V+
GND
.
NO NC
.
+12 V
LOCK
COM
OUTDOOR PANEL
POWER SUPPLY
SGND CTRL
v PGND
Lock Lock
ATTENTION: THE LOCK OPENING TIME IS SET BY ADJUSTING THE RESISTOR ON THE DELAY MODULE BOARD SH-40.
Connection by an external power supply (AV-02 and AV-02FP) NETWORK SWITCH
CAT 5e
485485+ GND V+
GND
NO
.
COM
+12 V
V
OUTDOOR PANEL
+18 V
CTRL LOCK 1 LOCK 2 UPS DP/P
LOCK
13
MOUNTING MODEL
SOCKET
WATERPROOF COMPACTORS
WIRES
OUTDOOR PANEL
104
THE HOLES FOR THE SCREWS SCREWS
NICHE 60
GUTTER
PLATE WITH THE NUMBER BRACKET HOLE FOR WATER RUNOFF. PLEASE DO NOT COVER DURING MOUNTING.
14
PROTECTIVE COVER
MOUNTING
THE HOLES FOR THE SCREWS
SCREWS
46
GUTTER
BRACKET HOLE FOR WATER RUNOFF. PLEASE DO NOT COVER DURING MOUNTING.
15
APPEARANCE Model: BA-04 v3.0SIP Backlight Camera
Loudspeaker
Call button Microphone
Apartment number
Light sensor Concierge button Reader for contactless cards and keys
Model: BA-08 v3.0 SIP Backlight Camera
Loudspeaker
Call button Microphone
Apartment number
Light sensor Concierge button Reader for contactless cards and keys
16
SPECIFICATIONS Panel type Individual
Protection class
Screen
Operating temperature
No
-40 – +65 0С
Camera
Power consumption
1/3”, adjustment of the camera direction
5,5 W, in standby – 2,5 W
Angle
Power
71° horizontal × 56° vertical
+ 12 V
Resolution
Body
800 TVL
Metal
Output video
Colors
D1 (704×576), H.264 Main Profile,
Titanium-grey
BaseLine Profile
Dimensions for installation
IP65
180×104×60 mm Night backlight 6 LEDs
Dimensions of panel 192×116×45 mm
Light sensitivity
Installation
0,01 Lux
Flush mount, wall mount
EQUIPMENT
Key
Sealing ring
Set screws
17
SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it with a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings. In the Internet browser in the address bar, enter the IP-address of the outdoor panel, and then enter the username and password. The username to enter the settings: admin. The password required for entry must match the password for access to the outdoor panel settings and is an installer’s password, default: 123456.
1. Network Settings. Select «Network» to access the network configuration settings.
18
SETTING THROUGH WEB INTERFACE 2. Device Settings. Select «Device» to access the configuration of the logical address, the operating mode and ringtones:
BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number. Panel mode: Set the operating mode «Unit Panel». The number of the building, entrance, floor, and apartment must match the address of the internal monitor, which will receive a call from this outdoor panel. If you have several outdoor panels that have one logical address, then, enter a value of 2, 3, 4, 5 and so on, until 9 in the “No” field. If the logical addressing of the outdoor panel corresponds to the addressing of the monitor, and the IP addresses of the devices are in the same local network segment, the devices will find each other, and the call will occur correctly. To make a call via the internal protocol to the internal monitor you must put “0” in the “Floor” field. Then when you call from the outdoor panel, the call comes to the internal monitor.
19
SETTING THROUGH WEB INTERFACE 3. Access Settings. Select «Access» to setting the opening time and the delay time of delay forthe opening the door:
Registration for contactless cards via WEB-interface. Enter in the “Master-card” number 0, and then click «Apply». Within 20 seconds, bring the required fregistration master card to the area of the outdoor panel’s reader – an alarm sounds “BEEP”, which means that the master-card has been registered successfully. Now each user cards can be brought to the panel’s reader. After each user card, a ”BEEP” will sound which indicates a successful registration of the card. The time between adding cards should not exceed 10 seconds. 4. SIP settings. Select «VOIP» for the transition to SIP account settings:
20
SETTING THROUGH WEB INTERFACE Proxy: SIP-server address can be specified as both the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: the domain address of the SIP-server is often the same as the IP address of the SIP-server. Password: Enter the password for the SIP-account (SIP-number). Stun IP and Stun Port: indicates if this outdoor panel is mounted after NAT, for example, a router. Username: indicated directly SIP-account (SIP-number). 5. Making calls. Select «Forward» to go to the next interface.
21
SETTING THROUGH WEB INTERFACE The numbers of call buttons look as follows: 0001
0005
0002
0006
0001
0003
0003
0007
0002
0004
0004
0008
Also, this section may be used for forwarding calls made by the SIP protocol when there is no internal monitor, on any given SIP-account (SIP-number). 1. In the “Apartment” field, enter the number of the call button after clicking on which call forwarding will occur. The order of numbers of the call buttons is shown in the figure above. 2. In the “SIP-account”, enter the required SIP-number to which the call will come from the outdoor panel after pressing the corresponding button on it. 3. Click the “Apply” button to add values to the table. So that the outdoor panel canould make a call to multiple devices
After pressing the call button on the panel, the panel can call up to 8 devices simultaneously or in turn (switching to the call of the next number if the previous number does not respond within 25 seconds), depending on the selected divert mode in the tab “Device Settings”. So that the outdoor panel canould make a call to multiple devices, you need to enter the number of the apartment (floor + room) in the ”Room” field, after calling on which the call forwarding will occur, and in the “Account” field the numbers should be separated by a semicolon, like «sip:
[email protected] », where 101 – is the number you are calling, 192.168.1.99 – is the IP address of the SIP PBX or the IP address of the called SIP client (when the call is made on P2P).
22
SETTING THROUGH WEB INTERFACE 6. External Module settings (optional). Select «ExModule» to go to the following interface:
The address of the external VOIP-converter is set, which is transforms the SIP protocol in the PSTN (Public Switched Telephone Network). 7. Advanced settings. Select “Advanced” to enter the following interface:
Quick Call: Call the Concierge monitor address with the help of the direct dial button located on the front of the outdoor panel. Set in this format: «sip:
[email protected]», where 1234 – is a number of the building that has been set in the concierge monitor and 192.168.1.101 – is the IP-address of the concierge monitor. Note: In multi apartment outdoor panels, BA-04 and BA-08, it is necessary to put a check mark in front of the “Speed Dial” field. Otherwise these outdoor panels will not be able to make calls.
23
SETTING THROUGH WEB INTERFACE 8. Sign Out. Select «Sign Out» to enter the next interface:
Click «Apply» button to exit the WEB-interface of the outdoor panel. Getting streaming video via RTSP: To get display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, enter the address the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where address – is the IP-address of the current outdoor panel. Next, the panel will request a username and password (the default use name: admin, password: 123456).You can enter this username and password into the initialization string before the address, and then the string of receiving streaming video will look like the following example: rtsp://admin:
[email protected]:8554/ch01
24
CONNECTION SCHEME Connection using an external power supply. For connecting high power electric locks, you must use an additional power supply. The BA-04 and BA-08 connection diagram from the included power supply, with an electromechanical lock is presented below:
Network switch BLACK RED YELLOW
“EXIT“ COTACT 2
v
“EXIT“ COTACT 1
“EXIT“ BUTTON
v Lock Power supply
25
CONNECTION SCHEME Connection using an external power supply. For connecting high power electric locks, you must use an additional power supply. The BA-04 and BA-08 connection diagram from the included power supply, with an electromechanical lock is presented below:
Network switch
v
“EXIT“ CONTACT 1
“EXIT“ CONTACT 2
“EXIT“ BUTTON
LOCK
V
POWER SUPPLY
V
Attention: The opening time is set by adjusting the resistor on the delay module board SH-40.
26
Delay module SH-40
CONNECTION SCHEME Connection by a Uninterruptible Power Supply (UPS). For connecting high power electric locks you must use an additional power supply. The BA- 04 and BA-08 connection diagram from the uninterruptible power supply, with an electromechanical or electromagnetic lock is presented below:
Network switch
BLACK RED YELLOW
“EXIT“ CONTACT 2
V
“EXIT“ CONTACT 1
“EXIT“ BUTTON
Attention: 1. The lock opening time is set by djusting the resistor on the uninterruptible power supply board UPS – DP/P.
V V
2. The type of lock: electromechanical or electromagnetic is set by the switch on the uninterruptible power supply board UPS – DP/P.
LOCK
Uninterruptible power supply UPS – DP/P.
27
MOUNTING Model: BA-04/08 v3.0 SIP Wall mounting
Dimensions of the bracket = 142 × 245 × 55 мм
Outdoor panel
Screws
Attention: The hole in the bottom of the bracket is designed to drain off water, do not cover it. It is also necessary to put the discharge gutter at the bottom of the niche, which is used to drain the water out.
28
Bracket
APPEARANCE Multi apartment outdoor panels
BACKLIGHT
BACKLIGHT LOUDSPEAKER
CAMERA
LOUDSPEAKER
CAMERA
LCD DISPLAY
1
A
4D 7
LIGHT SENSOR
*
G
2
B
6F
8
9
0
H J
BUTTONS
3C
5E
BUTTONS
I
#
LIGHT SENSOR MICROPHONE
MICROPHONE
READER FOR CONTACTLESS CARDS AND KEYS
READER FOR CONTACTLESS CARDS AND KEYS
CAMERA BACKLIGHT
LOUDSPEAKER LCD DISPLAY
BUTTONS
MICROPHONE READER FOR CONTACTLESS CARDS AND KEYS
29
MAIN FUNCTIONS 1. The bright backlight of buttons and backlights for video cameras. 2. Graphic LCD display with backlight and support for the Rrussian language. 3. Color camera with night mode function. 4. Making calls to internal monitors, centralized remote concierge. 5. Multifunction possibilities of opening doors using access cards, contactless key fobs, password access, opening with individual monitors and remote concierge.
TECHNICAL PARAMETERS Power supply: + 12 V Operating temperature: -40 – +65 °C Power consumption in standby mode: 3.6 W Power consumption in operation mode: 6.5 W The camera angle: ± 15° vertical, ± 20° horizontal Video resolution: 700p Protection class: IP65 Dimensions of the panels without bracket: Model AA-01: 150×372×55 mm Model AA-03: 155×375×47 mm Model AA-05: 155×375×47 mm Type of protocol output for ACS: Wiegand 26
30
SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it with a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings. In the Internet browser in the address bar, enter the IP-address of the outdoor panel, and then enter the username and password. The username to enter the settings: admin. The password required for entry must match the password for access to the outdoor panel settings and is an installer’s password, default: 123456. 1. Network Settings. Select «Network» to access the network configuration settings:
2. Device Settings. Select «Device» to access the configuration of the logical address, the operating mode and ringtones:
31
SETTING THROUGH WEB INTERFACE BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number. Panel mode: Set the operating mode «Unit Panel». The number of the building, entrance, floor, and apartment must match the address of the internal monitor, which will receive a call from this outdoor panel. If you have several outdoor panels that have one Logical Adress , then enter a value of 2, 3, 4, 5 and so on, until 9 in the “No” field. If the logical adress of the outdoor panel corresponds to the logical adress of the monitor, and the IP addresses of the devices are in the same local network segment – the devices will find each other, and the call will occur correctly. 3. Access Settings. Select «Access» for setting the opening time and the delay time for opening the door:
Registration for contactless cards via WEB-interface. Enter in the “Master-card” number 0, and then click «Apply». Within 20 seconds, bring the required registration master card to the area of the outdoor panel’s reader – an alarm sounds and a “BEEP” means that the master-card has been registered successfully. Next, the user cards can be brought to the panel’s reader. After each user card , a ”BEEP” will sound which indicates a successful registration of the card. The time between adding of cards should not exceed 10 seconds.
32
SETTING THROUGH WEB INTERFACE 4. SIP settings. Select «VOIP» for the transition to SIP account settings:
Proxy: SIP-server address can be specified as both the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: domain address of SIP-server is often the same as the IP address of the SIP-server. Password: Enter the password for the SIP-account (SIP-number). Stun IP and Stun Port: indicates if this outdoor panel is mounted after NAT, for example, a router. Username: indicated directly SIP-account (SIP-number). 5. Making calls. Select «Forward» to go to the next interface.
33
SETTING THROUGH WEB INTERFACE This section is used to forward calls received at the internal monitors when the monitor is not available or it has been disabled on any given SIP-account (SIP-number). Apartment: enter the number of the apartment after calling on which the call forwarding will occur. The apartment number consists of 2 digits (number of the floor) plus 2 digits (number of the apartments) in the settings of the internal monitor. SIP-account: enter the required SIP-number that the call will come to from the outdoor panel when dialing the appropriate apartment. For example: If number 5 was entered into the “Apartment” field, and number 0005 in the “SIP-account” field when you type apartment #5 on the outdoor panel , the panel will make a call to the SIP-account of “0005”. If number 101 was entered into the “Apartment” field , and №12340575 was entered into the «SIP-account”, when you typed apartment #101 on the outdoor panel, the panel will make a call to the SIP-account “12340575”. Delete: Enter the check mark to remove forwarding to the SIP-number in the forwarding table, when dialing a certain apartment. For example: if number 234 was entered into the “Apartment” field, and there is a check mark in front of the “Delete” field, when you click «Confirm» the call forwarding to the specified SIP-number when dialing the apartment #234 will be deleted. The corresponding line in the forwarding table will also be deleted. Note: the outdoor panel will forward a call to the specified SIP-account only if there is no internal monitor corresponding to the number of this apartment. If there is an internal monitor in this apartment, then it will be able to forward the call to specified SIP-account by itself. Since 2015, the functionality of P2P SIP calls, which allows you to make calls to SIP-clients within the local network without SIP PBX was added to the software of outdoor panels. So that outdoor panel can make a call to SIP-client for P2P networks, you must enter the number of apartments (floor + room) in the “RoomNo” field, after calling on which the call forwarding will occur, and in the “Account” field the numbers like «sip:
[email protected] », where 0001 – is the desired number to display, 192.168.1.223 – IP address SIP client (if using softphone – IP address of the device on which the softphone is installed). The device on which the call is forwarding must have a static IP address on the network.
34
SETTING THROUGH WEB INTERFACE In the settings of the device on which the call is coming, you must create a SIP-account in where you specify the IP address of the outdoor panel as the SIP server address, the desired display number from the preceding paragraph as a login and leave the password field empty. After pressing the call button on the panel, the panel can call up to 8 devices simultaneously or in turn (switching to the call of the next number if the previous number does not respond within 25 seconds), depending on the selected divert mode in the tab “Device Settings”. So that the outdoor panel can make a call to multiple devices, enter the number of the apartment (floor + room) in the ”Room” field, after calling on which the call forwarding will occur, and in the “Account” field, separate the numbers with a semicolon, like «sip:
[email protected] », where 101 – is the number you are calling, 192.168.1.99 – IP address of the SIP PBX or IP address of the called SIP client (when the call is made on P2P). 6. External Module settings (optional). Select «ExModule» to go to the following interface:
The address of the external VOIP-converter is set, which is transforms the SIP protocol in the PSTN (Public Switched Telephone Network).
35
SETTING THROUGH WEB INTERFACE 7. Advanced settings. Select “Advanced” to enter the following interface:
Advertisement: set the advertising that will be displayed on the outdoor panel screen when the panel goes into standby mode. Time: set the time after which the advertising will begin to display. Address: specify the address of the page with ads for standby mode. Quick Call: the function of call instead of a concierge. If there is no concierge monitor in the house, you can specify an address in this tab to which a call will come. Set it in the format: «sip:
[email protected]», where 1234 – is a number of the building set in the monitor that will be used instead of the concierge monitor and 192.168.1.101 – is the IP-address of the monitor.
36
SETTING THROUGH WEB INTERFACE 8. Sign Out. Select «Sign Out» to enter the next interface:
Click the «Apply» button to exit the WEB-interface of the outdoor panel. Getting streaming video via RTSP: To display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, enter the address of the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where the address – is the IP-address of the current outdoor panel. Next, the panel will request a username and password (the default username: admin, password: 123456). You can just enter this username and password into the initialization string before the address, then the string of receiving streaming video will look like the following example: rtsp://admin:
[email protected]:8554/ch01
37
CONNECTION SCHEME
V
UPS - DP/P
2.GND 3.NC 4.CTRL 5.LOCK 6.GND
COM
COM
button
sensor
Door contact
Exit button
LOCK
1.EXIT 2.GND 3.GND 4.DOOR
RJ45
3
4
GND 485+ 485
12
Wiegand 26 Yellow
Data 0
Red
Data 1
Black
GND
Attention: 1. The lock opening time is set by adjusting the resistor on uninterruptible power supply board UPS – DP/P. 2. The type of lock: electromechanical or electromagnetic is set by the switch on the uninterruptible power supply board UPS – DP/P.
38
INSTALLATION Model: AA-01 (v2.0 and v3.0 SIP) Wall mounting
Dimensions of the bracket
39 × 350 ×
Outdoor panel
Niche The hole in the bottom of the bracket is designed to drain off water, do not cover it. It is also necessary to make the discharge gutter at the bottom of the niche, which will be used to drain the water out.
Bracket
Screws
Model Wall mounting
The hole in the bottom of the bracket is designed to drain off water, do not cover it. It is also necessary to make the discharge gutter at the bottom of the niche, which will be used to drain the water out.
Dimensions of the bracket
× 355 ×
Niche Screws
Bracket
39
APPEARANCE Internal monitors
Speakerphone Photo frame
Power indicator Message indicator
Concierge View Open
40
Security indicator Alarm indicator
MAIN FUNCTIONS 1. Touch screen made by SpeedRight technology. 2. Intuitive interface for management and configuration. Changeable wallpapers, passwords for the user and installer, additional settings via the WEB-interface. 3. Video intercom between the internal monitors. 4. Support of 8 loops of home alarm, which can be connected to any security sensors with NO or NC contacts. 5. Connect up to 16 IP cameras with ONVIF protocol support. 6. Support of 9 individual plus 9 multi apartment outdoor panels. 7. Integration with VOIP, PSTN, support of the SIP protocol. 8. Applications for smartphones and tablets (Android, iOS). 9. Connection of 8 additional monitors to the main one. 10. Recording of photo-, video- and audio file from the outdoor panels. 11. Receiving text and graphic messages from special software. 12. Answering machine with a record of video or audio messages. 13. Reproduction of audio, video and photos from the connected SD-card. 14. Management and connection of home automation modules. 15. Quick and easy connection via Ethernet and RJ45. 16. Use of protocol stack TCP/IP allows you to work in a standard local network without conflicting with other devices. 17. Operation in the picture frame mode or monitor to view IP cameras. 18. Simple software update via the SD-card or network.
TECHNICAL PARAMETERS 1. Power supply: +12 V 2. Operating temperature: 0 - 55 °C 3. Power consumption in operating mode: 6 W 4. Power consumption in standby mode: 2.5 W 5. Talking mode: speakerphone «Hands-Free» 6. Conversation time between internal monitors: up to 5 minutes 7. Conversation time with individual outdoor panel: 4 minutes 8. Conversation time with multi apartment outdoor panel: 4 minutes 9. The minimum required channel width in the Ethernet network: 1.5 Mbit 10. Storage temperature: -10 - +65 °C
41
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE
Main screen: Sequrity, VOIP, Smart, Service, Contacts, Media Player. Status icons: Service, the SIP status, Voice recorder, Security, Mute. The functionality of status icons: 1. Services: Order of services, access to the specified WEB-page, receiving news. Messages and status of the local network. 2. SIP Status: lights when connected successfully to the SIP server. 3. Voice recorder: quick access to voice records. 4. Security: blinks during when turning on the security mode, and glows during security mode. Time of turning on security mode: 100 seconds. 5. Mute: used to activate “Do Not Disturb”. 6. Messages: quick access to the received messages menu. 7. Network Status: displays the current status of the LAN connection.
42
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 1. Security. Depending on the model of the internal monitor, can be from 4 to 8 loops security alarm. Click the “Security” to enter the interface:
Alarms can be set in different modes: “Home”, “Out” and “Sleep”.
1.1 Switching security modes. 1.1.1 Switching security on. Press the “At home”, “Outside” or “Sleep” mode button to activate the appropriate protection. During arming, a predetermined time from 0 to 300 seconds, the tone of “beep-beep” will sound, and then the monitor will arm. 1.1.2 Switching the security off. To stop the armed mode, you must press the “Off” button, then the alarm will be disabled.
43
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 2. IP-cameras. Click the “Camera IP» button to enter the viewing interface IP-based cameras:
Press the “Right” or “Left” button to select the desired camera. Then, press the camera button to view it and pause button to stop. 3. Communication. Click “Link” to enter the following interface, consisting of the “Call”, “Browse”, “Record”, “Address”, “the SIP” and “Settings”.
44
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 3.1 Wieving outdoor panels. Push the “Monitor“ button to go to the following interfase.
By clicking on the word “Door01“ you can switch between personal panel and milti-apartment panel. Use the “Right” and “Left” buttons to choose the number of multi-apartment and individual panels.To view the selected panel, press the button “Watch”, and to complete - the button “Pause”. To open the door while viewing the selected panel, press the “Opening the lock” button. 3.2 Calls. 3.2.1 Calls between internal monitors. Enter from 1 to 4 digits of the house and click on “Building”, then enter the 2 digits of the front door and press the “door”, then enter 1 to 4 digits of the apartment and press the call button. To delete a digit entered incorrectly, use the “Delete” button.
45
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 3.2.2 Intercom. The system supports the function of the video intercom, through cameras that are built into the internal monitors. In order to transmit your image to another person, it is necessaryyou need to turn on a built-in camera. Answering machine: When the outdoor panel’s call button is pressed, the monitor, in addition to automatic recording of images, can also record audio and video. For this, you must turn on the appropriate buttons in the given settings. Recording audio and video files is made only on a removable SD-card. To access additional internal monitors or call the main monitor, select from the list (primary, Add.1 - Add.9) and press the call button. 3.2.3 Calls to SIP-numbers and mobile phone numbers. To make VoIP calls, simply you dial the SIP-address to which you want to make a call. To make a call on a cell phone is necessary to dial a mobile number in international format with “+” digit in the front of the number. 3.2.4 To answer the incoming call. During an incoming call the following interface will appear:
Press the “Answer” button to answer the call, and press the “End” to end the call. Press the “Open lock” button to open the door. W During a conversation with the visitor, press the “Photo” button to save the current image in the internal memory of the monitor. To record a video, click the “Video” and press the “microphone” button to disable the built-in microphone.
46
SETTING THROUGH WEB INTERFACE 1. Network Settings. Select «Network» to access the network configuration settings:
2. Device Settings. Select «Device» to access the configuration of the logical address, the operating mode and ringtones.
47
SETTING THROUGH WEB INTERFACE Building (House): specify the house number which must consist of numbers with values from 1 to 9999. Entrance: specify the entrance number which should be set within the range from 1 to 99. Floor: specify the floor number within the range of 0 to 99. Apartment: specify the apartment number within the range of 0 to 99. Note: The building, entrance, floor, and apartment number must match the address of the internal monitor, which will receive a call from the given outdoor panel. For example: If the outdoor panel has set the values like “Building” = 1, “Entrance” = 1, “Floor” = 0, “Apartment” = 5, it will make the call on the internal monitor which has exactly the same values address settings in “Building”, “Entrance”, “Floor” and “Apartment” fields. Panel number: the serial number of individual outdoor panel, which is set within the range from 1 to 9. The system password: specify a password for access to the panel settings which is also an installer password, which is the default 123456. Ringtone: select a call melody that will sound from the panel’s speaker as “Call confirmation melody” at the time of making a call to the internal monitor or SIP-client. 3. SIP settings. Select «VOIP» for the transition to SIP account settings:
Proxy: SIP-server address can be specified as both the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: domain address of SIP-server is often the same as the IP address of the SIP-server. Password: Enter the password for the SIP-account (SIP-number). Stun IP and Stun Port: indicates if this monitor is mounted after NAT, for example, a router. Username: indicated directly SIP-account (SIP-number).
48
SETTING THROUGH WEB INTERFACE 7. Advanced settings. Select “Advanced” to enter the following interface:
Forwarding: Enable or disable forwarding of incoming calls to a specified SIP-address (SIP-number). When this option is enabled, the internal monitor will simultaneously make a call to a given SIP-address when it receives any incoming call. You can set two SIP-addresses. 5. Adding IP cameras. Connect your computer to the same subnet as the internal monitor, then in the browser enter its IP-address (http: // IP-address of the internal monitor), to enter the set interface and add the IP cameras. Enter the user name and password (the default user name is «user», and the password is 1234). Then click the tab “Installation IPC», to configure the IP cameras:
49
SETTING THROUGH WEB INTERFACE The ONVIF string – should appear automatically as RTSP stream initialization string. If it does not appear, then the IP camera does not have a ONVIF, or its ONVIF specification does not meet the standards. In this case, the parameters must be filled manually, but you do not need to fill in the ONVIF field. Name: enter the name of the IP camera. User: enter the user name for access to the IP camera. Password: enter the user password to access the IP camera. CHI: you must enter the IP address of the camera and its RTSP initialization string. 6. Sign Out. Select «Sign Out» to enter the next interface:
Click «Apply» button to exit the WEB-interface of the internal monitor. You can find more detailed instructions on setting up the internal monitor functions on our website in the download section.
50
CONNECTION SCHEME
V+ V1+GND
NC1 NC2 NC3
UTP CAT 5e
NC4 NC5 NC6 NC7 +12VGND485+485-
NC8 GND
SH-61
Connection of the sockets on the back of the internal monitor.
51
APPEARANCE Model AM-01 v3.
Build-in camera (optionally) Handset
Power indicator
View button Door release button
52
MAIN FUNCTIONS 1. Touch screen. 2. Photo and video recording of visitors. 3. The connection between the internal monitors and outdoor panels. 4. Viewing all authorized outdoor panels and lock control.
TECHNICAL PARAMETERS 1. 9” TFT screen with touch control 2. Dimensions: 303×195×29.5 mm 3. Mounting type: desktop 4. Power supply: + 12 V 5. Operating temperature: 0 - 55 °C 6. Power consumption in operating mode: 6.7 W 7. Power consumption in standby mode: 4.7 W 8. Conversation time: 4 minutes 9. Viewing time: 30 seconds
53
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE Main screen
Communication: enter the calls menu View: enter the viewing outdoor panels menu. Call history: view the call history Applications: enter the additional functions menu Alarm records: view alarm messages System settings: access to the setup menu
54
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 1. Network settings.
IP addresses may not be identical withinin the same subnet. Network default: 255.255.255.000. Usually it is not necessary to change its values. To change the values of the required parameters, click, enter the required values, and click “Confirm”.
55
CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 2. The logical address settings.
1. In the “Building” field you must enter the logical adress of the concierge monitor. The IP-Address of the building must correspond to the building logical adress in the settings of the devices used. 2. Enter 0 in the “Main” field in the main concierge monitor. For additional monitors, enter values from 1 to 8. 3. The “Sync” field should match on the main and additional monitors. Enter 6 digits in this field that must be identical on the main concierge monitor and additional monitors. This field must be filled in order to get calls on the monitors simultaneously. 4. Configuring the logical adress. Click «Address» to enter the logical adress configuration interface. Note: If you do not program the «Call instead concierge» on internal monitors and multi apartment outdoor panels, this button will call the concierge monitors with the building number from 1 to 5. So that to internal monitors and outdoor panels can call the concierge monitor which has the same house number, you must program the concierge call button in the web interface settings of internal monitors and outdoor panels!
56
NOTES Technical maintenance of devices 1. Keep the devices clean and use a dry cloth for cleaning soft dust. 2. When cleaning the devices, please turn off the power. 3. If the device is very contaminated and cannot be cleaned with a dry cloth, please use a soft cloth dampened with diluted detergent, and then wipe it dry with a cloth. Do not use petrol, solvents or organic solutions for cleaning as, they may damage the body and change the device color. Note the following: 1. Carefully read the operating instructions. Be sure to save themit for future use. 2. Use only the supplied power supply units, and also make sure your network meets the listed power specifications intended for the power supply. If you are not sure – consult your dealer or your local power company. 3. Do not apply strong shocks and drop of devices. If the device has been damaged, immediately contact an authorized service center. 4. Do not operate the device in aggressive environments. The location must be selected away from electromagnetic fields. In order to avoid electromagnetic interference – do not place the device near high-power power supplies and power cables. 5. Do not install or operate the device in the direct sunlight, heavy rain, high temperatures, high humidity or dust sources. 6. Do not use the outdoor panels and monitors in areas of strong backlight or in direct sunlight. 7. Turn off the power during installation. 8. Do not disassemble the device by yourself. If repairs are required, please contact your dealer or authorized service center.
57
Terms of warranty 1. The warranty card must indicate the name of the model, serial number, purchase date, name of the seller, seal of the trade organization and the customer’s signature. Delivery to the warranty repair is the responsibility of the buyer. 3. Warranty repairs will be carried out only during the warranty period specified in the warranty card. 4. The service center is committed to do everything possible to carry out the repair warranty products, up to 24 working days. The period spent on the restoration of product functionality is added to the warranty period.
Breach of terms of warranty 1. This warranty is invalid if the serial number on the product is altered, deleted, removed or made illegible. 2. The warranty is invalid in case of any changes and adaptations in order to improve or expand the scope of device usage listed in the instruction manual. 3. The guarantee becomes invalid when the product has been used for other purposes or not in accordance with the manual for operation and maintenance. 4. The warranty becomes invalid in case of accidental or intentional contact with foreign objects, substances, liquids, vapors, corrosive gases, insects in the internal or external part of the product. 5. The warranty becomes invalid in case of a the wrong connection of the product with other systems, or incorrect mounting and installation. 6. The warranty does not cover defects and damages of any system in which the product has been implemented or in conjunction with which has been used. 7. The guarantee is invalid if there is mechanical damages on the product, splits, dents, cracks, traces of tampering, etc. 8. The guarantee does not apply to the product, if there is damage caused by the mismatch of the State standards of supply parameters, telecommunication, cable networks and other similar external factors. 9. This warranty does not apply to products which have internal or external damage due to external factors such as natural disasters, fires, floods, lightning, thunder, voltage fluctuations and other causes beyond the control of the manufacturer. 10. The guarantee becomes invalid when you try to repair products by unauthorized service centers or other individuals and organizations that do not have the legal authority to repair these products. 11. The warranty does not include accessories (batteries, an external power supply, connecting cables), as well as components and parts of the product which are out of order as a result of natural wear.
The warranty card number _______________
The model name
________________________
Serial number
________________________
Full name of the seller
________________________
With following stated terms of warranty is familiar, functional test was performed in my presence: Customer signature: _____________________________________________________
The warranty period of the product - 24 (twenty- four) months from the date of sale. - Transportation of the product must be in its original packaging or one supplied by the seller. - The product is accepted in warranty repair only with a properly filled warranty card and the presence of intact stickers or labels. - The product is accepted for examination in accordance with the cases provided by law, only in the original packaging, in a full complete set, and its appearance corresponding to the new equipment and presence of all relevant properly filled documents. - This warranty is in addition to the constitutional and other consumer rights and in no way restricts them.