www.contractorlighting.com Batteries 01S-C6V7 6V 7aH Sealed SPECIFICATIONS Nomial Voltage 6V Nomial Capacity (20HR) 7AH Dimension Length Width Container Height Total Height (with Terminal) 151 + -1mm (5.94 inches) 34 + -1mm (1.34 inches) 94+ -1mm (3.70 inches) 100+ -1mm (3.94 inches) 1.15 kg (2.54 lbs) Approximate Weight Terminal T1 / T2 Container Material ABS (20hr,1.80V/cell,25 0C/77 0F) (10hr,1.80V/cell,25 0C/77 0F) 0 0 (5hr,1.75V/cell,25 C/77 F) 0 0 (3hr,1.75V/cell,25 C/77 F) 0 0 (1hr,1.60V/cell,25 C/77 F) Rated Capacity 105A (5s) Internal Resistance Approx 1 m Operating Temp. Range Discharge : - 15~50 C (5~122 F) 0 0 Charge : 0~40 C (32~104 F) 0 0 Storage : - 15~40 C (5~104 F) Nominal Operating Temp. Range 0 0 25+ - 5 F) - 3 C (77+ Capacity affected by Temperature Self Discharge Electric wheelchairs, scooters, bikes Alarm and security systems 0 Standby Use Uninterruptible Power Supply (UPS) Electronic apparatus and equipment Max. Discharge Current Cycle Use APPLICATIONS 0 Emergency lighting Medical devices Electric carts Initial Charging Current less than 2.1. Voltage 0 0 Telecom equipment 0 7.2V~7.5V at 25 C (77 F) Temp. Coefficient -15mV/ C Switchgear No limit on Initial Charging Current Voltage Solar power systems 6.75V~6.9V at 250C (770 F) Temp. Coefficient -10mV/ 0C 40oC (104oF) 103% 100% 25oC (77oF) 86% 0 oC (32oF) National Battery batteries may be stored for up to 1 year 0 0 at 25 C (77 F) and then a freshening charge is recommended For higher temperatures the time interval will be shorter. Constant Current Discharge (Amperes) at 25 C (77F) Constant Power Discharge (Watts) at 25 C (77F) UL R LISTED www.contractorlighting.com Batteries 6V 7aH Sealed Lead Acid DIMENSIONS T1 Terminal 6.35 ( 0.25 ) Warning: Risk o f f ire, e xplosion, o r burns. Do n heat a bove t he 5 0 O C, o r incinerate. V V 2.55 A UL R LISTED No n-spillable B ATTE R Y M US T B E R EC Y CL ED NATIONAL BATTERY FLOAT CHARGING CHARACTERISTICS 12V 6V 4V 2V Battery Battery Battery Battery 0 Charge Charging Charging Volume Current Voltage 0 Temperature : 25 C ( 77 F) 6.5 4.33 151+ -1 ot d isassemble, DISCHARGE CHARACTERISTICS 13.0 34+ -1 CONSTANT VOLTAGE CHARGE Standby use: 6.75 -6.9 Cycle use: 7.2-7.5 Initial current: Less than 2.16 Terminal Voltage (V) % 12.0 6.0 4.00 2.00 11.0 5.5 3.66 1.84 0.093C 0.05C 120 110 100 90 80 0.207C 10.0 5.0 3.33 1.68 9.0 4.5 3.00 1.52 0.4C 4.0 2.67 50 40 30 20 1.36 3C 1 2 4 2C 6 8 10 40 60 20 (XCA) 2 6 8 10 4 Min 10 0 20 H Charging Voltage 0.10CA-2.25V/cell (V) (V) 15.0 7.5 14.0 7.0 2.33 Charge Voltage ( C onstant 2.25v/cell) 0.15 13.0 2.17 6.5 After 50% Discharge 0.10 12.0 6.0 0.05 11.0 5.5 2.00 After 100% Discharge 1.83 Charging Current 0 4 8 32 28 36 40 8 6 5 4 Life expectancy (year) Capacity % 24 EFFECTS OF TEMP. ON LONG TERM FLOAT LIFE A 0 .0 5 C A 0 .1 C 0. 2C A 60 1 .0 C A 40 2 .0 C 20 A 3. 0C A Charging voltage : 2.25V/cell 3 2 1 0.5 -10 0 10 30 20 40 50 30 86 20 68 0 Temperature ( C) 100 0 100 80 60 50% DOD 600 A 800 1000 25 C B 60 300C 0 40 C 40 C 20 0 30% DOD 2 4 6 8 10 12 Storage Time (Months) Ambient Termperature: 25oC (77oF) 400 10 C 80 Remaining Capacity (%) Ambient teperature:25 5 C 120 200 C F 0 0 0 20 0 SELF DISCHARGE CHARACTERISTICS Testing condition Discharging: current 0.17C (FV 1.7V/cell); Charging: current 0.25C max, voltage 2.45V/cell; Charging volume : 125% of discharged capacity. 100% DOD 50 122 40 104 Battery temperature CYCLE LIFE IN RELATION TO DEPTH OF DISCHARGE Capcity (%) 20 10 80 0 0 16 12 Charging Time (hours) 120 40 2.50 Charged Volume 0 TEMP. EFFECTS IN RELATION TO BATTERY CAPACITY 100 (V) 0.20 Discharge Time 0 -20 temperature 250C 0.25 70 60 0.628C 1C 8.0 4.5 3.2 ( 0.126 ) C18D (6V7 AH) BATTERY Maintenance-free Sealed Lead-acid Battery 94+ -1 100 + -1 0.8 (0.031) 4.75 (0.187) Unit: mm ( inches ) A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1. Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2. Charged for above 20 hours at limted current 0.25CA and constant volatge 2.45V/cell. 3. Charged for 8~10 hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles