VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET LC-P0612P For standby power supplies. Expected trickle life: Approx. 6 years at 25°C, Approx. 10 years at 20°C. Dimensions (mm) Terminal type: Faston 187 or Faston 250 + 0.039 1.969 - 0.020 50 +- 1.0 0.5 0.236 (6) 5.945 +- 0.059 0.020 151 +- 1.5 0.5 5.913 (150.2) Photo/Label for reference only. Specifications 6V 12Ah 5.945 inches (151.0 mm) Width 1.969 inches (50.0 mm) Height 3.702 inches (94.0 mm) Total Height* 3.937 inches (100.0 mm) Approx. mass 4.41 lbs. (2.0 kg) LC-P0612P1 UL94V-0 Faston 250 UL94V-0 Faston 187  LC-P0612P Discharge characteristics 77°F (25°C) (Note) Terminal voltage (V) Dimensions 7.2 6.9 6.6 6.3 6.0 5.7 5.4 5.1 4.8 4.5 4.2 3.9 * The total height with #250 terminal is 101.5mm. 12A 1 2 4 2 4 6 8 10 20 40 (Hour) Trickle use Control voltage 20 15 10 5.8A Approx. 15mΩ 102% 100% 85% 65% 91% 82% 64% (Note) 30 12Ah 11.3Ah 10.4Ah 8.1Ah (Hour) 20 hour rate (600mA) 10 hour rate (1130mA) 5 hour rate (2080mA) 1 hour rate (8100mA) 1.5 hour rate discharge Cut-off voltage 5.25 V Fully charged battery 77˚F (25˚C) 104˚F (40˚C) 77˚F (25˚C) 32˚F (0˚C) 5˚F (-15˚C) Residual capacity after standing 3 months Residual capacity after standing 6 months Residual capacity after standing 12 months Initial current Duration of discharge Self discharge 77˚F (25˚C) 40 60 Duration of discharge vs. Discharge current 104˚F (40˚C) 5 4 3 77˚F (25˚C) 2 1.5 32˚F (0˚C) 1 50 40 5˚F (-15˚C) 30 (Minute) Temperature dependency of capacity (20 hour rate) 20 Duration of discharge Characteristics Internal Resistance 6 8 10 (Minute) minimum order quantities. Capacity (note) 77˚F (25˚C) 1.2A 0.6A 3A 6A 24A 0 ♦ Please contact Panasonic for availability on optional items. Optional items may be subject to Charge Method (Constant Voltage) 1.937 (49.2) Battery case resin: Standard (UL94V-0) Color is grey. Nominal Voltage Rated capacity (20 hour rate) Length Standard Terminals and Resin Optional Terminals and Resin 0.012 (0.3) + 0.059 0.63 (16) 3.701- 0.020 (94 +- 1.5 0.5 ) 5.13 (130.3) 20 10 1.8 A or smaller 6.8V to 6.9V (per 6V cell 25˚C) 5 3 300 500 (Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values. (Note) For cycle use of the battery, please contact us in advance. VRLA BATTERIES (mA) 1 3 5 10 30 50 100 (A) Discharge current AUGUST 2005 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.