Preview only show first 10 pages with watermark. For full document please download

Batteries Rechargeable Batteries Lead Acid Vrla Batteries Lc Series Lcr067r2p Data Sheet

   EMBED


Share

Transcript

VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET LC-R067R2P For main and standby power supplies. Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C. Dimensions (mm) Terminal type: Faston 187 or Faston 250 + 1.339 - 0.059 0.020 34 -+ 1.5 0.5 + 0.236 (6) 5.945 - 0.059 0.020 + (151 - 1.5 0.5 ) + 0.059 0.354 (9) 3.701- 0.020 (94 +- 1.5 0.5 ) 5.13 (130.3) 0.012 (0.3) Photo/Label for reference only. 5.913 (150.2) Specifications Dimensions 6V 7.2Ah 5.945 inches (151.0 mm) Width 1.339 inches (34.0 mm) Height 3.702 inches (94.0 mm) Total Height* 3.937 inches (100.0 mm) Approx. mass Standard Terminals and Resin Optional Terminals and Resin 2.78 lbs. (1.26 kg) UL94HB Faston 187 LC-R067R2P UL94HB Faston 250 LC-R067R2P1 UL94HB Faston 187/250  LC-R067R2P2 Battery case resin: Standard (UL94HB) Color is black. Discharge characteristics 77°F (25°C) (Note) Terminal voltage (V) Nominal Voltage Rated Capacity (20 hour rate) Length 1.307 (33.2) 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 ♦ Please contact Panasonic for availability on optional items. Optional items may be subject to 2.88A 1.44A 11.52A 23.04A 0 1 minimum order quantities. 0.72A 0.36A 5.76A 2 4 6 8 10 20 40 60 2 4 (Minute) 6 8 10 20 40 (Hour) Discharge time Characteristics Self discharge 77˚F (25˚C) Charge Method (Constant Voltage) Cycle use (Repeating use) 3.5A 10 Approx. 20mΩ 102% 100% 85% 65% 91% 82% 64% Initial current 2.88 A or smaller Control voltage 7.25V to 7.45V (per 6V cell 25˚C) Initial current 1.08 A or smaller Control voltage 6.8V to 6.9V (per 6V cell 25˚C) Trickle use 20 15 (Hour) Temperature dependency of capacity (20 hour rate) (Note) 30 Duration of discharge Internal Resistance 7.2Ah 6.8Ah 6.3Ah 4.9Ah 104˚F (40˚C) 5 4 3 2 1.5 77˚F (25˚C) 32˚F (0˚C) 5˚F (-15˚C) 1 50 40 30 (Minute) Capacity (note) 77˚F (25˚C) Duration of discharge vs. Discharge current 20 hour rate (360mA) 10 hour rate (680mA) 5 hour rate (1260mA) 1 hour rate (4900mA) 1.5 hour rate discharge Cut-off voltage 5.25 V Fully charged battery 77˚F (25˚C) 104˚F (40˚C) 77˚F (25˚C) 32˚F (0˚C) 5˚F (-15˚C) Residual capacity after standing 3 months Residual capacity after standing 6 months Residual capacity after standing 12 months (Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values. VRLA BATTERIES 20 10 5 3 100 300 500 1 3 5 (mA) 10 30 50 (A) Discharge current AUGUST 2005 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.