Preview only show first 10 pages with watermark. For full document please download

Battery Analyzer Ba5100

   EMBED


Share

Transcript

Bat t ery Anal yzer BA5100 CHARGE DISCHARGE EIS CYCLING WITH EIS Features - Programmable battery charger of 5V/100A - Programmable load 100A/400W continuous and peak pulse current up to 300A/1s for hybrid pulse power characteristic test - Impedance response analyzer for EIS measurements; 0.05Hz to 10KHz - Battery cycling test for estimating SoC and SoH - Impedance measurements; Nyquist plot, terminal resistance, charge transfer resistance, diffusion capacitance and cell's inductance - Simultaneously measurement of voltage, current, temperature and impedance - Precision coulomb counter for battery pack gas gauge calibration - EIS Analog Interface for external high power charger and load for stack measurements - Interface for external DC contactor in order to isolate the battery under test - Ultra-capacitor measurement - Standard Ethernet, USB and RS-232 interface for application software Specif icat ions CHARGE Programming Voltage Range 2 ~ 5V EIS (Electrochemical Impedance Spectroscope) Impedance Frequency Range 0.05 ~ 10KHz Resolution 1mV Resolution 0.01Hz Accuracy ± 0.05% +0.1% Amplitude Programming Current Range Galvano 0.1% to 20% of the current range 0 ~ 100A Accuracy 0.2% , 0.1° with auto-sampling interval Resolution 10mA Connection 4-terminals Accuracy ± 0.05% +0.1% Cutoff Condition Time, CC to CV+Time, Temp, Capacity GENERAL User Interface Display 20x2 characters OLED Input 16Keys and rotary Remote Interface Ethernet, USB, RS232 DISCHARGE Programming Current Range 0 ~ 100A, Pulse 0 ~ 300A/ 1s Resolution 10mA Mechanical and Environmental Dimension 44H x 445W x 568L mm Accuracy ± 0.05% +0.1% Weight 10KG Cutoff Condition Time, Vfinal, Capacity Operating Temperature 0 ~ 40? Mode Continuous, List, Pulse Storage Temperature -30 ~ 70? Power Requirement Voltage 90 ~ 250VAC MEASUREMENT Voltage Range 0 ~ 5.5V Frequency 50/ 60Hz Resolution 1mV Watt 700W @ 100A charging Accuracy ± 0.05% +0.1% Current Range -300A ~ +100A SOFTWARE Charge/ Discharge Test Mode Resolution 10mA Accuracy ± 0.05% +0.1% Temperature Range -40 ~ 100? Resolution 0.1? Accuracy ± 1? Coulomb Range -200 ~ +200Ah Resolution 0.001Ah Accuracy ±0.2% Parameter Setting EIS Display Mode I-V, Cycle life, Charge/ discharge rate CV charge, CC charge, CC discharge, Pulse current discharge, List mode for charge/ discharge, Cutoff condition Nyquist, Meter readout of voltage, current, Z(real) and Z(imaginary) Design and specifications subject to change without notice Biol ogic Technol ogy Inc. 5F., No. 93, Xinhu First Rd., Neihu Dist., Taipei City, Taiwan, 114 www.biologictek.com.tw +886-2-2792-6976 [email protected]