Transcript
Technical Data TXG50c Digital Color Progressive Scan Camera
System:
Gigabit Ethernet
Art. No:
11002848 (OD108178)
Baumer TXG50c Revision 2.1
• • • • • • • • • • • • • • • • • •
Gigabit Ethernet progressive scan CCD camera 2448 x 2050 pixel Up to 15 full frames per second GigE Vision® standard compliant On board integrated color processor for high quality color calculation Outstanding image quality High sensitivity and dynamic range High quality slow scan mode for lowest readout noise True partial scan function (ROI) for increased frame rates External synchronization via industrial compliant process interface (trigger / flash) Integrated supplementary function for flexible integration Jumbo frames supported Integrated 32 MByte RAM for temporarily image data buffering Camera parameter programmable in real-time Ultra compact and lightweight aluminum housing Standard RJ45 connector Screw-lock type industrial connector Baumer-GAPI: Flexible, generic software interface for Windows / Linux
1. Overview Model Name Sensor Shutter / readout mode Number of pixel Scan area Pixel size Color filter Operation modes Trigger mode Free running mode Signal processing Pixel clock A/D converter Exposure control (texp) Gain control Offset (black level) Image data buffer
TXG50c 2/3“ interline progressive scan CCD global shutter / progressive scan readout 2448 x 2050 8.45 mm x 7.07 mm 3.45 µm x 3.45 µm RGB Bayer mosaic yes, overlapped operation yes, overlapped operation real-time software programmable 60 MHz fast scan / 30 MHz high quality (HQ) scan 14 bit total: 4 µsec .. 2 sec step: 1 µsec 0 .. 20 dB 0 .. 1023 LSB (14 bit) max. 1 image
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 1 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c Image acquisition Camera image format modes
Format (pixel)
GenCam standard
Format ID
Pixel format BayerRG8 BayerRG12 Mono8 YUV411 Packed YUV422 Packed **) YUV444 Packed RGB8 Packed BGR8 Packed BayerRG8 BayerRG12 Mono8 YUV411 Packed **) YUV422 Packed n.b. n.b. n.b.
Full frame HQ
slow
2448 x 2050
Vendor specific
00
Full frame
fast
2448 x 2050
yes
01
Standard features Image size controls Pixel format
Test image selector
Partial scan Analog controls Gain Black Level (Off set) Gamma Acquisition and Trigger Acquisition mode Acquisition frame rate
Trigger source Trigger delay Sequencer Digital I/O Lines Line source (outputs only) Line debouncer
Event Generation Events
Pixel clock MHz 30
Frames per sec. *) 7.5
133 msec
60
15
67 msec
treadout
BayerRG8, BayerRG12, Mono8, YUV411 Packed, YUV422 Packed, YUV444 Packed, RGB8 Packed, BGR8 Packed yes, in all modes Off, GreyHorizontalRamp, GreyVerticalRamp, HorizontalLineMoving, VerticalLineMoving HorizontalAndVerticalLineMoving yes, format freely programmable in all modes yes yes no Continuous yes, ON / OFF (only in freerunning mode) 0 .. 47 Hz, step: 0.01 Hz HardwareTrigger (Line0), SoftwareTrigger, CommandTrigger (ActionCommand), All or Off 0 .. 2 sec, 512 trigger can be tracked, step: 1 µsec no Input: Line0, Output: Line1 Line1: Off, ExposureActive, Timer1, ReadoutActive, User0, TriggerReady, TriggerOverlapped, TriggerSkipped yes, low and high signal separately selectable 0 .. 5 msec step: 1 µsec GigEVisionError, Heartbeattimeout, TemperatureExceeded, EventLost, Line0RisingEdge, Line0FallingEdge, Line1RisingEdge, Line1FallingEdge, ExposureStart, ExposureEnd, FrameStart, FrameEnd, TriggerReady, TriggerOverlapped, TriggerSkipped yes, ON / OFF
Event Notification Counters and Timers Framecounter
32
yes, 2 can be set by user yes, TimerSelector: Timer1 TimerTriggerSource: Off, Input: Line0, SoftwareTrigger, CommandTrigger (ActionCommand), ExposureStart, ExposureEnd, FrameStart, FrameEnd, TriggerSkipped TimerDelay: 0 µsec .. 2 sec, step: 1 µsec TimerDuration: 10 µsec .. 2 sec, step: 1 µsec
Timer
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 2 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c LUT Controls LUT selector Defect pixel correction (custom) Defect pixel list (custom) GigEVisionTransportLayer PayLoadsize TransmissionDelay (custom) UserSets User set selector UserSetDefaultSelector Advanced features Time stamp function Asynchronous message channel Concatenation function User defined identifier ActionCommand DeviceTemperature
Data quality Readout noise Dynamic range Optical interface Optical filter Process interface functions Async. Trigger
Exposure Active (External flash sync)
User Output Timer Software reset Asynchronous reset Image info header Electrical interface Data / control
no yes, ON / OFF yes, max. 256 pixel coordinates (x, y) can be stored 4 Byte .. 15.055.472 Byte 32 0 .. 2 -1 ticks Default (factory settings / read only) UserSet1, UserSet2, UserSet3 (read and write) yes, define the start up “UserSet” yes, 64 bit tick = 32 nsec yes yes yes, user programmable permanent identifier yes, ID 0 = Trigger yes, internal camera temperature range: -25 °C .. +100 °C accuracy: ±1 K (temperature value is notified as asynchronous message event) at 20 °C, gain = 1, exposure time = 32 msec, full frame mode, slow scan σ < 0.5 LSB (8 bit) typical typical > 54 dB C-Mount on request: CS-Mount Hoya E-CM500S on request: dust protection, daylight filter or no filter yes, trigger mode operation, “Off”, “software trigger”, “hardware trigger”, “command trigger” or “all” separately selectable (overtriggered signals and trigger signals during the readout time will be notified in the received image header) yes, delay_value (tdelay flash) ≤ 4 µsec, duration_value (tduration): slow mode = texp + 64 µsec fast mode = texp + 32 µsec yes, ON / OFF yes, Timer1 yes, delay up to 133 msec Full frame slow delay up to 45 msec fast 24 msec yes standard single cable 1000 Base-T, Cat6 recommended / minimum Cat5e option: screw lock type connector VCC: 8 VDC .. 30 VDC I: 615 mA .. 190 mA approx. 5.2 Watt Line 0: trigger signal, opto decoupled UIN(low) = 0 .. 4.5 VDC, UIN(high) = 11 .. 30 VDC IIN = 6 .. 10 mA / 7 mA typical rising edge (invert = false) ****) min. impulse length (tmin): 2 µsec trigger delay out of treadout (tdelay trigger): 3 µsec max. trigger delay during treadout (tdelay trigger): slow mode = 64 µsec fast mode = 32 µsec Line 1: opto decoupled UEXT = 5 .. 30 VDC / 24 VDC typical, IOUT = max. 16 mA high active (invert = false) ****)
Power Power consumption Digital input
Digital output
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 3 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c LED
1: green: yellow: 2: green: green flash: yellow: yellow/red flash:
Environmental Storage temperature Operating temperature
Housing operating temperature Humidity Conformity Housing Dimensions Weight 1000 Base-T interface Ethernet IP configuration Stream channel packet size Interpacketgap Multicast function Resend function Software
*) **) ***) ****)
Power on Readout active Link Phy (1 GBit) Ethernet RX Ethernet TX Ethernet RX/TX
-10 °C .. +70 °C +5 °C .. +50 °C ****) between +25 °C .. +50 °C, note the max. housing temperature see application note max. +50 °C 10 % .. 90 % non condensing CE, FCC Part 15 class B, UL, RoHS compliant aluminum, IP40 3 36 x 36 x 48 mm < 90 g 1000BASE-T (1000 Mbit / sec) persistent IP / DHCP / LLA 576 Byte (default) .. 65535 Byte jumbo frames supported 32 0 .. 2 -1 ticks yes yes Baumer-GAPI SDK with supported OS socket driver and Baumer filter driver / SDK for Windows XP (32 bit) / Windows Vista (32 bit / 64 bit) / Windows 7 (32 bit / 64 bit) / Linux Kernel 2.6.xx (64 bit / 32 bit) ® GigE Vision compatible programs and image processing libraries supported Windows / Linux depending on the actually driver software is used
maximum frame rate in free running mode, effective frame rate depending on camera image format mode settings and set exposure time (texp < treadout) default pixel format bandwidth of GigE interface is limiting frame rate can be inverted via software
2. Camera Factory Settings after Camera Start-up Camera factory settings after camera start-up free running mode
Operation modes Signal processing Exposure control Gain control Offset (black level) Image acquisition Camera image format mode Partial scan function Acquisition frame rate Timer Transmission delay Test image selector Defect pixel correction Electrical interface Digital input
1:
Digital output
1:
32 msec factor 1 = 0 dB 0 mode id = 01, full frame YUV411 Packed not active Off Off 0 ticks Off On Line0 disabled, digital output set to low status (high impedance) invert = false line source = Exposure Active Line1 disabled invert = false trigger source = Line0
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 4 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c 3. Timing Operation Modes Trigger Mode: start up time U UIN (high)
start active trigger 11 V
0V
tdelay trigger
t
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 5 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c Trigger Mode: trigger mode 0, overlapped trigger parameter * Frame n+1 effective
parameter * Frame n effective exposure time Frame n effective
trigger
exposure time Frame n+1 effective earliest possible Trigger
exposure time Frame n+2 effective earliest possible Trigger
tmin
tmin
tmin
tdelay trigger
tdelay trigger
tdelay trigger
exposure
texp(n)
texp(n+1)
readout
texp(n+2)
treadout(n+1)
treadout(n) Frame n
Frame n+1
tnot ready
ready for trigger **
tdelay flash flash
texp(n)
tdelay flash
texp(n+1)
tdelay flash
texp(n+2)
texp < treadout: tearliest possible trigger (n+1) = treadout(n) - texp(n+1) texp > treadout: tearliest possible trigger (n+1) = texp(n) texp < treadout: tnot ready (n+1)
= texp(n) + treadout(n) - texp(n+1)
texp > treadout: tnot ready (n+1)
= texp(n)
* image parameter:
offset global gain mode partial scan
** signal will be notified as event “TriggerReady” and is not available as digital output
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 6 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c Trigger Mode: trigger mode 0, overlapped trigger , when texp (n+2) > texp (n+1) parameter * Frame n effective exposure time Frame n effective
trigger
parameter * Frame n+1 effective
exposure time Frame n+1 effective earliest possible Trigger
exposure time Frame n+2 effective earliest possible Trigger
tmin
tmin
tmin
tdelay trigger
tdelay trigger
tdelay trigger
exposure
texp(n)
readout
texp(n+1)
texp(n+2)
treadout(n+1)
treadout(n) Frame n
Frame n+1
tnot ready
ready for trigger **
tdelay flash
tdelay flash
texp(n)
texp(n+1)
tdelay flash
flash texp(n+2)
texp < treadout: tearliest possible trigger (n+1) = treadout(n) - texp(n+1) texp > treadout: tearliest possible trigger (n+1) = texp(n) texp < treadout: tnot ready (n+1)
= texp(n) + treadout(n) - texp(n+1)
texp > treadout: tnot ready (n+1)
= texp(n)
* image parameter:
offset global gain mode partial scan
** signal will be notified as event “TriggerReady” and is not available as digital output
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 7 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c Trigger Mode: trigger mode 0, overlapped trigger , when texp (n+2) < texp (n+1) parameter * parameter * Frame n Frame n+1 effective effective exposure time exposure time Frame n+1 Frame n effective effective earliest possible Trigger
trigger
tmin
tmin
tdelay trigger
tdelay trigger
exposure
texp(n)
earliest possible Trigger tmin
texp(n+1)
readout
treadout(n+1)
treadout(n) Frame n
Frame n+1
tnot ready
ready for trigger **
tdelay flash
tdelay flash
texp(n)
texp(n+1)
flash
texp < treadout: tearliest possible trigger (n+1) = treadout(n) - texp(n+1)
Frame n+2 not started / overtriggered
texp > treadout: tearliest possible trigger (n+1) = texp(n) texp < treadout: tnot ready (n+1)
= texp(n) + treadout(n) - texp(n+1)
texp > treadout: tnot ready (n+1)
= texp(n)
* image parameter:
offset global gain mode partial scan
** signal will be notified as event “TriggerReady” and is not available as digital output
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 8 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c Free Running Mode: overlapped operation
parameter * parameter * parameter * Frame n-1 Frame n Frame n+1 effective effective effective exposure time exposure time Frame n Frame n effective effective
exposure
texp(n)
readout
flash
treadout(n-1)
treadout(n)
treadout(n+1)
Frame n-1
Frame n
Frame n+1
tdelay flash texp(n)
* image parameter:
texp(n+1)
tdelay flash texp(n+1)
offset global gain mode partial scan
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 9 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c 4. Housing
36 20
8,2 ±0,25 temperature measurement point 26
26
ø 30
48
Back View
36
1,7
4 - M3 depth 6
26
9,1 24,5 27
Side View
Front View
C-Mount 7
3,5
2 - M2 depth 5
8,1 18
8 - M3 depth 4,5
3,5
26
Top View
5. Connectors / Electrical Interfaces 5.1
Pin assignment: Type: RJ45 8P8C mod jack
Data / Control 1000 Base-T
8
1
1: 2: 3: 4: 5: 6: 7: 8:
MX1+ MX1MX2+ MX3+ MX3MX2MX4+ MX4-
2 4 1
Type: Lumberg RSMESD / 3 pin
Power
4 1
3
/ Type: Lumberg RSMESD 4pin.
Trigger Flash
1: Power VCC+ 3: Power GND 4: not used
Power cable wires color: 1 = brown 3 = blue 4 = black
3
*) resistor must be used, IOUT = 16 mA by UEXT = 24 VDC recommended, drawing shown above example for using high active signal
Trigger / Flash cable wires color *): 1 = brown 2 = white 3 = blue 4 = black *) shielded trigger / flash cable should be used and ordered separately
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 10 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213
Technical Data TXG50c 5.2
Flash sync sample UEXT = 24 VDC high active:
5.3
Flash sync sample UEXT = 24 VDC low active:
Technical specifications subject to change Baumer Optronic GmbH Last change: 22.12.2010
Badstrasse 30
DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Page 11 / 12
Fax +49 (0)3528 4386 86 www.baumer.com Version: TDS_TXG50c_v60e_101213