Specifications for One (1) Fire Service Pumper Conventional 6 Man Crew Cab with Cross Controls for the R.M. of Blanshard, Oak River, MB
Request for Quotation As per specifications provided, you are invited to submit pricing and delivery for one (1) Triple Combination Pumper Apparatus with an Open Cross Control Pump Panel. Bidders are to reply to the specifications on the forms supplied, plus include detailed specifications for the apparatus. Bidders are advised to quote as per the outlined specifications. The R.M. of Blanshard has concluded on the design/equipment content, and is requesting complete adherence to the specifications. It is the intent of this Request for Quote to specify a Triple Combination Pumper Apparatus on a commercial chassis. The apparatus is intended as an operational response unit for the R.M. of Blanshard. The unit must be designed to withstand the rigours associated with off-highway emergency service, as well as all kinds of weather extremes. The vehicle is expected to perform suitably during emergency driving conditions at its gross weight rating without appreciable concerns for control (i.e.; sway, diminished handling, acceleration or braking distance). The unit shall be built and tested to meet the most recent edition of the NFPA 1901 Standard for Automotive Fire Apparatus (2009 Edition), and will have proof of this requirement affixed to the apparatus. The unit will meet all SAE, D.O.T. and CMVSS requirements where applicable. General The following specifications describe in detail the design, quality and fabrication method for a new triple combination pumper. The information contained within this document reflects the design and quality of apparatus expected by the fire department. Quotations will be evaluated on the basis of several criteria. These include compliance with design and construction requirements, history with bidder/manufacturer, reputation of bidder/manufacturer, and prior response-to-service request time of bidder/manufacturer. Service must be provided within 12 hours of notification. The lowest price may not necessarily be accepted! The decision of the Fire Department and the Municipality of Blanshard is final. Companies submitting proposals agree that they will respect this decision and that they will not challenge the decision. Submissions to be in the following format: • Two (2) complete hard copy packages complete with diagrams For clarifications or questions, please contact Fire Chief Jim Kuculym, cell# 204 867-7029 or email at
[email protected] Fire Department Member, Vern Davidson, cell#701-871-1436 or email @
[email protected]
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Manufacturer’s Quality Control System It is the intent of the fire department to purchase from a company that has implemented a quality control system that meets the following minimum requirements. • • • • • • •
Continuous review and improvement of our design and manufacturing processes Business systems and vendor relationships Documented inspection procedure for completed apparatus Documented archiving of all engineering, accounting and other data files Internal and external component testing Parts inventory control Warranty and customer service management
Manufacturer’s Responses Quotations will be accepted only from suppliers who provide detailed specifications outlining the design, fabrication and components of the firefighting apparatus. Quotations that do not include acceptable detailed specifications will be rejected. The specifications contained within this document outline the minimum acceptable requirements. PRICING Supply One (1) Triple Combination Pumper Apparatus and additional equipment as per specifications provided. Apparatus Selling Price (each):
$Canadian____________________.
Taxes
$Canadian____________________.
Total Price
$Canadian____________________.
F.O.B. delivered to OAK RIVER, Manitoba: Delivery date shall be prior to ____________
.
This Request for Quote shall be returned to the: R. M. of Blanshard c/o Diane Kuculym. C.A.O. Box 179 OAK RIVER, MB ROK 1T0 No later than APRIL 5TH, 2013, at 12 NOON Please note "R.M. of Blanshard' Fire Pumper Bid" on the front of the package.
2
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 WARRANTIES Warranty will take effect at the time of delivery of the completed unit. Please specify: Chassis Warranty:
________________________________________
Engine Transmission Warranty
________________________________________
Plumbing Warranty:
________________________________________
Body Structural Warranty:
________________________________________
Water Tank Warranty:
________________________________________
Water Tank Warranty Provider Accessories & Equipment:
________________________________________
Electrical & Components Warranty:
________________________________________
Paint & Corrosion Warranty:
________________________________________
A complete operational test of the chassis, pump and all components will be conducted after the apparatus inspection, upon delivery. The manufacturer’s representative will be in attendance for the duration of this test. Any deficiencies shall be resolved by the manufacturer immediately! A representative from the manufacturer shall provide instruction and operation of the apparatus when the unit is delivered. The apparatus builder will supply complete technical reference manuals for all systems including, but not limited to; chassis, engine, transmission, pump and foam systems. Two (2) complete operation, maintenance & electrical wiring diagram manuals will be supplied with each apparatus.
Apparatus Builder:
________________________________
Address:
________________________________ ________________________________ ________________________________
Authorized Representative: ________________________________ Signature:
________________________________
Date:
_____________________________
3
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 REQUEST FOR QUOTATIONS Model Profile 2014 4400 SBA 4X2 (MA035) APPLICATION: Fire/Pumper (Emergency) MISSION: Requested GVWR: 35000. Calc. GVWR: 40000 Calc. Start / Grade Ability: 44.30% / 3.01% @ 55 MPH Calc. Geared Speed: 75.8 MPH FUEL ECONOMY: 7.73 MPG @ 55 MPH DIMENSION: Wheelbase: 256.00, CA: 145.00, Axle to Frame: 63.00 ENGINE, DIESEL: {MaxxForce 9} EPA 10, 330 HP @ 2000 RPM, 950 lb-ft Torque @ 1200 RPM, 2200 RPM Governed Speed TRANSMISSION, AUTOMATIC: {Allison 3500EVS_P} 4th Generation Controls; Wide Ratio, 6-Speed; With Double Overdrive, Includes Oil Level Sensor, With Provision for PTO, Less Retarder, With 80,000-lb GVW & GCW Max. CLUTCH: Omit Item (Clutch & Control) AXLE, FRONT NON-DRIVING: {Meritor MFS-14-143A} Wide Track, I-Beam Type, 14,000-lb Capacity AXLE, REAR, SINGLE: {Dana Spicer S26-190D} Single Reduction, 26,000-lb Capacity, R Wheel Ends, Driver Controlled Locking Differential Gear Ratio: 5.57 CAB: Conventional 6-Man Crew Cab TIRE, FRONT: (2) 315/80R22.5 UNISTEEL G291 (GOODYEAR) 491 rev/mile, load range J, 18 ply TIRE, REAR: (4) 12R22.5 G282 MSD (GOODYEAR) 481 rev/mile, load range H, 16 ply SUSPENSION, RR, SPRING, SINGLE:Vari-Rate; 31,000-lb Capacity, With 4500 lb Auxiliary Rubber Spring PAINT: Cab schematic 100GA Location 1: 2304, Red (Prem) Chassis schematic 932GA Wheel: 2304, Red (Prem) MA03500 Base Chassis, Model 4400 SBA 4X2 with 256.00 Wheelbase, 145.00 CA, and 63.00 Axle to Frame. 1570 TOW HOOK, FRONT (2) Frame Mounted 1CAH FRAME RAILS Heat Treated Alloy Steel (120,000 PSI Yield); 10.375" x 3.705" x 0.438" (263.5mm x 94.1mm x 11.1mm); 456.0" (11582mm) Maximum OAL 1LNN BUMPER, FRONT Full Width, Aerodynamic, Chrome Plated Steel; 0.142" Material Thickness 1WEK WHEELBASE RANGE 256" (650cm) Through and Including 311" (790cm) 2ARV AXLE, FRONT NON-DRIVING {Meritor MFS-14-143A} Wide Track, I-Beam Type, 14,000-lb Capacity Notes : The following features should be considered when calculating Front GAWR: Front Axles; Front Suspension; Brake System; Brakes, Front Air Cam; Wheels; Tires. 3ADD SUSPENSION, FRONT, SPRING Parabolic, Taper Leaf; 14,000-lb Capacity; With Shock Absorbers Includes : SPRING PINS Rubber Bushings, Maintenance-Free Notes : The following features should be considered when calculating Front GAWR: Front Axles; Front Suspension;
4
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Brake System; Brakes, Front Air Cam; Wheels; Tires. 4091 BRAKE SYSTEM, AIR Dual System for Straight Truck Applications Includes : BRAKE LINES Color and Size Coded Nylon : DRAIN VALVE Twist-Type : GAUGE, AIR PRESSURE (2) Air 1 and Air 2 Gauges; Located in Instrument Cluster : PARKING BRAKE CONTROL Yellow Knob, Located on Instrument Panel : PARKING BRAKE VALVE For Truck : QUICK RELEASE VALVE Bendix On Rear Axle for Spring Brake Release: 1 for 4x2, 2 for 6x4 : SLACK ADJUSTERS, FRONT Automatic : SLACK ADJUSTERS, REAR Automatic : SPRING BRAKE MODULATOR VALVE R-7 for 4x2, SR-7 with relay valve for 6x4 Notes : Front and Rear Dust Shields not Included : Rear Axle is Limited to 19,000-lb GAWR with Code 04091 BRAKE SYSTEM, AIR and Code 04NCL BRAKES, REAR, AIR CAM Regardless of Axle/Suspension Ordered. : Rear Axle is Limited to 20,000-lb GAWR with Code 04091 BRAKE SYSTEM, AIR and Code 04NCG BRAKES, REAR, AIR CAM Regardless of Axle/Suspension Ordered. : Rear Axle is Limited to 23,000-lb GAWR with Code 04091 BRAKE SYSTEM, AIR and Standard Rear Air Cam Brakes Regardless of Axle/Suspension Ordered. 4722 DRAIN VALVE {Bendix DV-2} Automatic; With Heater; for Air Tank Includes : DRAIN VALVE Mounted in Wet Tank 4773 BRAKE SHOES, REAR Cast Notes : Provides Rear Axle GAWR Up to 26,000-Lb. : The following features should be considered when calculating Rear GAWR: Rear Axles; Rear Suspension; Brake System; Brakes, Rear Air Cam; Brake Shoes, Rear; Special Rating, GAWR; Wheels; Tires. 4AZA AIR BRAKE ABS {Bendix AntiLock Brake System} Full Vehicle Wheel Control System (4-Channel) 4EBT AIR DRYER {Bendix AD-IP} With Heater Includes : AIR DRYER LOCATION Inside Left Rail, Back of Cab 4ESX BRAKE CHAMBERS, FRONT AXLE {Haldex} 20 SqIn 4EVL BRAKE CHAMBERS, REAR AXLE {Haldex GC3030LHDHO} 30/30 Spring Brake Includes : BRAKE CHAMBERS, SPRING (2) Rear Parking; WITH TRUCK BRAKES: All 4x2, 4x4; WITH TRACTOR BRAKES: All 4x2, 4x4; 6x4 & 6x6 with Rear Tandem Axles Less Than 46,000-lb. or GVWR Less Than 54,000lb. 4JCJ BRAKES, FRONT, AIR CAM S-Cam; 16.5" x 5.0"; Includes 20 Sq. In. Long Stroke Brake Chambers Notes : Front Axle with 14,000-lb GAWR is Limited to 13,200-lb GAWR when used in Conjunction with 15" BRAKES, FRONT, AIR CAM. : The following features should be considered when calculating Front GAWR: Front Axles; Front Suspension; Brake System; Brakes, Front Air Cam; Wheels; Tires. 4NDB BRAKES, REAR, AIR CAM S-Cam; 16.5" x 7.0"; Includes 30/30 Sq.In. Long Stroke Brake Chamber and Spring Actuated Parking Brake Notes : The following features should be considered when calculating Front GAWR: Front Axles; Front Suspension; Brake System; Brakes, Front Air Cam; Wheels; Tires. 4SBC AIR COMPRESSOR {Bendix Tu-Flo 550} 13.2 CFM Capacity 4VBC AIR DRYER LOCATION Mounted To Battery Box, Left side, Under Cab 5708 STEERING COLUMN Tilting
5
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 5CAL STEERING WHEEL 2-Spoke, 18" Diam., Black 5PSM STEERING GEAR {Sheppard HD94} Power 7BDC EXHAUST SYSTEM Single Horizontal, Aftertreatment Device, Frame Mounted Right Side, for Use With Long Tail Pipes Includes : NOTE: The Horizontal Tailpipe Includes a Temperature Control Device 7SCZ ENGINE EXHAUST BRAKE for MaxxForce I6 Engines, Electronically Activated 7WBZ TAIL PIPE Horizontal, Exits Right Side Outside of Body, At Rear Wheels 7WZY SWITCH, FOR EXHAUST 2 Position, Lighted & Latching, ON/OFF Type, Mounted in IP, Inhibits Diesel Particulate Filter Regeneration as Long as Switch is in ON Position 8000 ELECTRICAL SYSTEM 12-Volt, Standard Equipment Includes : BATTERY BOX Steel : DATA LINK CONNECTOR For Vehicle Programming and Diagnostics In Cab : FUSES, ELECTRICAL SAE Blade-Type : HAZARD SWITCH Push On/Push Off, Located on Top of Steering Column Cover : HEADLIGHT DIMMER SWITCH Integral with Turn Signal Lever : HORN, ELECTRIC Single : JUMP START STUD Located on Positive Terminal of Outermost Battery : PARKING LIGHT Integral with Front Turn Signal and Rear Tail Light : STARTER SWITCH Electric, Key Operated : STOP, TURN, TAIL & B/U LIGHTS Dual, Rear, Combination with Reflector : TURN SIGNAL SWITCH Self-Cancelling for Trucks, Manual Cancelling for Tractors, with Lane Change Feature : TURN SIGNALS, FRONT Includes Reflectors and Auxiliary Side Turn Signals, Solid State Flashers; Flush Mounted : WINDSHIELD WIPER SWITCH 2-Speed with Wash and Intermittent Feature (5 Pre-Set Delays), Integral with Turn Signal Lever : WINDSHIELD WIPERS Single Motor, Electric, Cowl Mounted : WIRING, CHASSIS Color Coded and Continuously Numbered 8630 IGNITION SWITCH Keyless 8718 POWER SOURCE Cigar Type Receptacle without Plug and Cord 8GWZ ALTERNATOR {Leece-Neville 14923PAH} Brush Type; 12 Volt 220 Amp. Capacity, Pad Mount, Includes 1Gauge Protected Charging Circuit 8HAE BODY BUILDER WIRING Rear of Frame; Includes Sealed Connectors for Tail/Amber Turn/Marker/ Backup/ Accessory Power/Ground and Sealed Connector for Stop/Turn 8MKL BATTERY SYSTEM {International} Maintenance-Free, (3) 12-Volt 1950CCA Total 8RKB RADIO {Panasonic CQ120} AM/FM, Includes Multiple Speakers, Includes Auxiliary Input Includes : SPEAKERS IN CAB (2) Dual-Cone with Deluxe Interior : SPEAKERS IN CAB (4) Coaxial with Premium Interior 8THB BACK-UP ALARM Electric, 102 dBA 8WBW JUMP START STUD Remote Mounted Includes : JUMP START STUD Mounted to Battery Box 8WCL HORN, AIR Black, Single Trumpet, Air Solenoid Operated 8WEA ALTERNATOR PULLEY 2.4” Diameter for increased Alternator Output at Idle; for Fire Truck Application with International Engines, Must Include Fire Truck Identity Code
6
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 8WJV BATTERY DISCONNECT SWITCH {Joseph Pollak} for Cab Power Disconnect Switch; Lever Operated, Disconnects Power to PDC, Does Not Disconnect Charging Circuits, Cab Mounted 8WPB HEADLIGHTS Halogen; Composite Aero Design for Two Light System; Includes Daytime Running Lights 8WPH CLEARANCE/MARKER LIGHTS (5) {Truck Lite} Amber LED Lights, Flush Mounted on Cab or Sunshade 8WPZ TEST EXTERIOR LIGHTS Pre-Trip Inspection will Cycle all Exterior Lamps Except Back-up Lights 8WTK STARTING MOTOR {Delco Remy 38MT Type 300} 12 Volt; less Thermal Over-Crank Protection 8WWJ INDICATOR, LOW COOLANT LEVEL With Audible Alarm 8XAH CIRCUIT BREAKERS Manual-Reset (Main Panel) SAE Type III With Trip Indicators, Replaces All Fuses Except For 5-Amp Fuses 9HBM GRILLE Stationary, Chrome 9WAY FRONT END Tilting, Fiberglass, With Three Piece Construction 9WBT GRILLE EMBER SCREEN Mounted to Grille and Cowl Tray to Keep Hot Embers out of Engine and HVAC Air Intake System 10060 PAINT SCHEMATIC, PT-1 Single Color, Design 100 Includes : PAINT SCHEMATIC ID LETTERS "GA" 10632 PAINT IDENTITY, PT-2 Single Color, Instruction No. 932. Wheels 10761 PAINT TYPE Base Coat/Clear Coat, 1-2 Tone 10769 PAINT CLASS Premium Color 10WBE KEYS - ALL ALIKE, ID Z-001 11001 CLUTCH Omit Item (Clutch & Control) 12712 OIL FILTER, ENGINE {Hudgins Model 960 Spinner} 12959 BLOCK HEATER, ENGINE {Phillips} 120 Volt/1250 Watt includes: BLOCK HEATER SOCKET Receptacle Type; Mounted below Drivers Door 12NUW ENGINE, DIESEL {MaxxForce 9} EPA 10, 330 HP @ 2000 RPM, 950 lb-ft Torque @ 1200 RPM, 2200 RPM Governed Speed Includes : AIR COMPRESSOR AIR SUPPLY LINE Naturally-Aspirated (Air Brake Chassis Only) : ANTI-FREEZE Red Shell Rotella Extended Life Coolant; -40 Degrees F/ -40 Degrees C; for MaxxForce Engines : COLD STARTING EQUIPMENT Intake Manifold Electric Grid Heater with Engine ECM Control : CRUISE CONTROL Electronic; Controls Integral to Steering Wheel : ENGINE OIL DRAIN PLUG Magnetic : ENGINE SHUTDOWN Electric, Key Operated : FUEL FILTER Included with Fuel/Water Separator : FUEL/WATER SEPARATOR Fuel/Water Separator and Fuel Filter in a Single Assembly; With Water-in-Fuel Sensor; Engine Mounted : GOVERNOR Electronic : OIL FILTER, ENGINE Spin-On Type : WET TYPE CYLINDER SLEEVES Notes : Recommend Code 12THT when using front mount obstructions (winches, cones, reels, etc.) that restrict air flow through the radiator. 12THT FAN DRIVE {Horton Drivemaster} Direct Drive Type, Two Speed With Residual Torque Device for Disengaged Fan Speed Includes : FAN Nylon
7
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Notes : Recommend Code 12THT when using front mount obstructions (winches, cones, reels, etc.) that restrict air flow through the radiator. 12UAU RADIATOR Aluminum; 2-Row, Cross Flow, Over Under System, 1045 SqIn Louvered, with 373 SqIn CAC, with 369 SqIn LTR, with In-Tank Transmission Oil Cooler Includes : DEAERATION SYSTEM with Surge Tank : HOSE CLAMPS, RADIATOR HOSES Gates Shrink Band Type; Thermoplastic Coolant Hose Clamps : RADIATOR HOSES Premium, Rubber 12UXE FEDERAL EMISSIONS for 2010; MaxxForce 9 & 10 Engines 12VBR AIR CLEANER With Service Protection Element Includes : GAUGE, AIR CLEANER RESTRICTION Air Cleaner Mounted 12VXT THROTTLE, HAND CONTROL Engine Speed Control; Electronic, Stationary, Variable Speed; Mounted on Steering Wheel 12VZA ENGINE CONTROL, REMOTE MOUNTED Provision for; Includes Wiring for Body Builder Installation of PTO Controls; With Ignition Switch Control for MaxxForce post 2007 Emissions Electronic Engines 12WBR FAN OVERRIDE Manual; With Electric Switch on Instrument Panel, (Fan On With Switch On) 12WTA FAN DRIVE SPECIAL EFFECTS Fan Cooling Ring with Fan Shroud Effects, Engine Mounted 12XAN OBD COMPLIANCE for 2013 OBD 13AJW TRANSMISSION, AUTOMATIC {Allison 3500EVS_P} 4th Generation Controls; Wide Ratio, 6-Speed; With Double Overdrive, Includes Oil Level Sensor, With Provision for PTO, Less Retarder, With 80,000-lb GVW & GCW Max. Includes : OIL FILTER, TRANSMISSION Mounted on Transmission : TRANSMISSION OIL PAN Magnet in Oil Pan 13WAW OIL COOLER, AUTO TRANSMISSION {Modine} Water to Oil, for Allison of CEEMAT Transmission 13WBL TRANSMISSION SHIFT CONTROL {Allison} Push-Button Type; for Allison 3000 & 4000 Series Transmission 13WLP TRANSMISSION OIL Synthetic; 29 thru 42 Pints 13WUE ALLISON SPARE INPUT/OUTPUT for Emergency Vehicle Series (EVS); Fire/Pumper, Tank, Aerial/Ladder 13WYL SHIFT CONTROL PARAMETERS Allison Performance Programming in Primary and Allison Economy Programming in Secondary 14AHL AXLE, REAR, SINGLE {Dana Spicer S26-190D} Single Reduction, 26,000-lb Capacity, R Wheel Ends, Driver Controlled Locking Differential . Gear Ratio: 5.57 Includes : REAR AXLE DRAIN PLUG (1) Magnetic, For Single Rear Axle Notes : The following features should be considered when calculating Rear GAWR: Rear Axles; Rear Suspension; Brake System; Brakes, Rear Air Cam; Brake Shoes, Rear; Special Rating, GAWR; Wheels; Tires. : When Specifying Axle Ratio, Check Performance Guidelines and TCAPE for Startability and Performance 14VAJ SUSPENSION, RR, SPRING, SINGLE Vari-Rate; 31,000-lb Capacity, With 4500 lb Auxiliary Rubber Spring Notes : The following features should be considered when calculating Rear GAWR: Rear Axles; Rear Suspension; Brake System; Brakes, Rear Air Cam; Brake Shoes, Rear; Special Rating, GAWR; Wheels; Tires. 15SGK FUEL TANK Top Draw; D Style, Non Polished Aluminum, 50 U.S. Gal., 189 L Capacity, 16" Deep, with Quick Connect Outlet, Mounted Right Side, Under Cab 16196 CAB Conventional 6-Man Crew Cab
8
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Includes : ARM REST (2) Molded Plastic; One Each Door : CLEARANCE/MARKER LIGHTS (5) Flush Mounted : COAT HOOK, CAB Located on Rear Wall, Centered Above Rear Window : CUP HOLDERS Two Cup Holders, Located in Lower Center of Instrument Panel : DOME LIGHT, CAB Rectangular, Door Activated and Push On-Off at Light Lens, Timed Theater Dimming, Integral to Console, Center Mounted : GLASS, ALL WINDOWS Tinted : GRAB HANDLE, CAB INTERIOR (1) "A" Pillar Mounted, Passenger Side : GRAB HANDLE, CAB INTERIOR (2) Front of "B" Pillar Mounted, One Each Side : GRAB HANDLE, CAB INTERIOR (4) Two Each Side, Rear Door Mounted at Hinge Side and "C" Pillar Mounted : INTERIOR SHEET METAL Upper Door (Above Window Ledge) Painted Exterior Color : STEP (8) Two Steps Per Door Notes: 43.9" CA Loss 16HBB GAUGE CLUSTER English With Metric Electronic Speedometer Includes : GAUGE CLUSTER (5) Engine Oil Pressure (Electronic), Water Temperature (Electronic), Fuel (Electronic), Tachometer (Electronic), Voltmeter : ODOMETER DISPLAY, Miles, Trip Miles, Engine Hours, Trip Hours, Fault Code Readout : WARNING SYSTEM Low Fuel, Low Oil Pressure, High Engine Coolant Temp, and Low Battery Voltage (Visual and Audible) Notes : Standard in Canada 16HCL SEATBELT WARNING PREWIRE Includes Seat Belt Switches and Seat Sensors for all Belted Positions in the Cab and a Harness Routed to the Center of the Dash for the Aftermarket Installation of the Data Recorder and Seatbelt Indicator Systems, for 4 to 6 Seat Belts 16HGH GAUGE, OIL TEMP, ALLISON TRAN 16HHE GAUGE, AIR CLEANER RESTRICTION {Filter-Minder} With Black Bezel Mounted in Instrument Panel 16HKT IP CLUSTER DISPLAY On Board Diagnostics Display of Fault Codes in Gauge Cluster 16JAJ SEAT, PASSENGER {H.O. Bostrom Tanker 450} for SCBA with SecureAll Locking System, Non-Suspension, High Back, Vinyl, Adjusters, 7-Degree Back Angle, With Covered Back, International Logo on Headrest 16JJG SEAT, DRIVER {H.O. Bostrom Sierra Air 100} NFPA Compliant, Air Suspension, High Back, Vinyl with Covered Back and International on Headrest for Fire Truck Includes : SEAT BELT 3-Point, Lap and Shoulder Belt Type 16RDZ SEAT, REAR {H.O. Bostrom Tanker 400CT} for SCBA with SecureAll Locking System, Three Individual Seats on One Riser, Non Suspension, High Back, Vinyl, With Covered Back and International on Head Rest 16SDC GRAB HANDLE (2) Chrome Towel Bar Type With Anti-Slip Rubber Inserts; for Cab Entry, Mounted Left and Right, Each Side at "B" Pillar 16SDU MIRRORS (2) {Lang Mekra} Styled; Rectangular, 7.09" x 15.75" & Integral Convex Both Sides, 102" Inside Spacing, Breakaway Type, Heated Heads Thermostatically Controlled, Power Both Sides, Clearance Lights LED, Bright Finish Heads & Brackets 16SDZ MIRROR, CONVEX, HOOD MOUNTED {Lang Mekra} Right and Left Side; 7.44" Sq., Bright 16VBW CAB MOUNTING HEIGHT EFFECTS Mid Cab in Lieu of Low Cab Mounting Height (Approx. 4") for Increased Cooling System Requirements 16VCA SEAT BELT All Red; 4 to 6 16WCT AIR CONDITIONER {Blend-Air} With Integral Heater & Defroster Includes : HEATER HOSES Premium : HOSE CLAMPS, HEATER HOSE Mubea Constant Tension Clamps : REFRIGERANT Hydrofluorocarbon HFC-134A
9
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 16WJS INSTRUMENT PANEL Center Section, Flat Panel 16WKY HVAC FRESH AIR FILTER 16WLE STORAGE POCKET, DOOR Molded Plastic, Full Width; Mounted on Passenger Door 16WSG CAB INTERIOR TRIM Deluxe; for Crew Cab Includes : "A" PILLAR COVER Molded Plastic : CAB INTERIOR TRIM PANELS Cloth Covered Molded Plastic, Full Height; All Exposed Interior Sheet Metal is Covered Except for the Following: with a Two-Man Passenger Seat or with a Full Bench Seat the Back Panel is Completely Void of Covering : CONSOLE, OVERHEAD Molded Plastic; With Dual Storage Pockets with Retainer Nets and CB Radio Pocket : DOOR TRIM PANELS Molded Plastic; Driver and Passenger Doors : FLOOR COVERING Rubber, Black : HEADLINER Soft Padded Cloth : INSTRUMENT PANEL TRIM Molded Plastic with Black Center Section : STORAGE POCKET, DOOR (1) Molded Plastic, Full-Length; Driver Door : SUN VISOR (2) Padded Vinyl with Driver Side Toll Ticket Strap, Integral to Console 16WSK CAB REAR SUSPENSION Air Bag Type 16XWD SUNSHADE, EXTERIOR Aerodynamic, Painted Roof Color; Includes Integral Clearance/Marker Lights 27DPL WHEELS, FRONT DISC; 22.5" Painted Steel, 5 Hand Hole, 10-Stud (285.75MM BC) Hub Piloted, Flanged Nut, Metric Mount, 9.00 DC Rims; With .500" Thick Disc, Non-Standard Offset and Steel Hubs Includes : PAINT IDENTITY, FRONT WHEELS White Notes : Aluminum Wheels not Painted or Coated : Compatible Tire Sizes: 12R22.5, 295/75R22.5, 295/80R22.5, 315/80R22.5 28DMA WHEELS, REAR DUAL DISC; 22.5" Painted Steel, 2 Hand Hole, 10-Stud (285.75MM BC) Hub Piloted, Flanged Nut, Metric Mount, 8.25 DC Rims; With Steel Hubs Includes : PAINT IDENTITY, REAR WHEELS White Notes : Compatible Tire Sizes: 11R22.5, 12R22.5, 255/70R22.5, 255/80R22.5, 265/75R22.5, 275/70R22.5, 275/80R22.5, 295/75R22.5, 295/80R22,5 60AAJ BDY INTG, REMOTE POWER MODULE (3) Mounted Inside Cab behind Driver Seat; Up to 6 Outputs & 6 Inputs each, Max. 20 amp. per Channel, Max. 80 amp Total (Includes 3 Switch Packs With Latched Switches) 60ABE BDY INTG, PTO ACCOMMODATION for Electric over Hydraulic PTO, Does Not Include Solenoids, With Latched Switch Mounted on Dash Includes Audible Alarm and Indicator Light in Gauge Cluster (Requires 1 Remote Power Module input & 1 output) 60ACU BDY INTG, SWITCH MOMNTRY 3POS (3) Rocker, Backlit, with "ON" Indicator Mounted on Dash, Latching Software, for 3; Auxiliary Load 20 amp. Maximum; Power Available Only in "Ignition" or "Accessory" Position, Output Also Controlled by a Customer Remote Mounted Switch (requires 3 Remote Power Module inputs & 3 outputs) 60AJR BDY INTG, DASH IND. LT RED (1) for Optional Usage Customer to Program 60AJV BDY INTG, DASH IND. LT GREEN (1) for Optional Usage Customer to Program 60AKL BDY INTG, HEADLIGHTS, WIG WAG High Beam Wig Wag With Park Brake Interlock, Park Brake Disables High Beam Wig Wag, Enables Low Beam Wig Wag 7382158105 (4) TIRE, REAR 12R22.5 G282 MSD (GOODYEAR) 481 rev/mile, load range H, 16 ply 7702540190 (2) TIRE, FRONT 315/80R22.5 UNISTEEL G291 (GOODYEAR) 491 rev/mile, load range J, 18 ply
10
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 The chassis shall be supplied as per the above specifications. No Exceptions YES □ NO □ One (1) first aid kit shall be supplied YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 5 lb. ABC fire extinguisher shall be YES □ NO □ mounted in the cab Comments: ____________________________________________________________________ ___________________________________________________________________________________ One set of three (3) dual faced triangular warning flares to meet YES □ NO □ D.O.T. CMVSS 125 shall be supplied Comments: ____________________________________________________________________ ___________________________________________________________________________________ Heavy duty rubber mud flaps will be installed at the cab wheels YES □ NO □ and rear body wheel well area Comments: ____________________________________________________________________ ___________________________________________________________________________________ Front tow hooks shall be mounted to the frame at the cab front bumper YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Heavy duty tow eyes shall be bolted directly to the rear frame rails. Tow eyes shall YES □ NO □ be chrome plated and installed above the back running board/step and not underneath. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The cab shall have door lettering and logo, to be specified by purchaser YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ The cab shall have white 4” reflective tape on both sides and the front YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ All parts and maintenance manuals will be supplied YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ APPARATUS BODY CONSTRUCTION This section refers to general construction of the Top Mount Pump House and Body. Including structure, compartments, hardware, electrical and finishing. The Body and Pump House are fabricated with the YES □ NO □ highest quality components available and acceptable to the fire service industry, only new components shall be used in the manufacturing process. Pump house shall be 100% aluminum, and stainless steel. no exceptions Comments: ____________________________________________________________________ ___________________________________________________________________________________
11
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Construction is engineered and designed to provide a low centre of gravity YES □ NO □ and carry a correct load distribution. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The entire sub-structure, frame and sub frame shall be constructed of YES □ NO □ heavy-duty aluminum extrusions and aluminum plates. A Formed Body shall NOT be excepted. Comments: ___________________________________________________________________ __________________________________________________________________________________ All aluminum checker plate trim shall be high-shine for the best YES □ NO □ finish and appearance Comments: ___________________________________________________________________ __________________________________________________________________________________ All components or attachments made from dissimilar metals shall be YES □ NO □ isolated in a manner that prevents corrosion. to metal contact corrosion. Comments: ___________________________________________________________________ __________________________________________________________________________________ A heavy duty bolt on type aluminum rub rail will be installed. The rub rail shall be YES □ NO □ spaced ¼” from the body surface to prevent trapping moisture. 2” White reflective striping shall be placed inside the rub rail flanges. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All step surfaces shall have anti-slip, multi-directional aggressive grip with YES □ NO □ self cleaning and draining features. Comments: ____________________________________________________________________ ___________________________________________________________________________________
Pump House The pump house shall be an open cross control type pump house, YES □ NO □ modular in construction, and shall be mounted independent of the body. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump house shall include the pump operators panel, two crosslays , YES □ NO □ a walk-way and running boards. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump house shall be mounted to the truck frame with elastomeric (rubber) YES □ NO □ mounts. This will assist in reducing vibrations. no exceptions Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump operator walk-way shall be a minimum twenty-two (22”) wide YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ 12
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Floor shall be non-slip serrated aluminum thread plate on the surface. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Two (2) - 20" Fire Research Mansaver Safety Bars shall be supplied & installed, YES □ NO □ one each side of the pump house walk way. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump operators panel and all steps shall be adequately YES □ NO □ lit with all switch controls operated at the panel. All Lighting to be LED, no exceptions. A 63” led strip light shall be placed above the operators panel underneath a hood to reduce glare. Two (2) 4” round led lights shall illuminate the walk-way, one each side. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The operator’s panel will consist of a hinged upper section that will YES □ NO □ include all gauges, meters and all electrical control switches. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The bottom fixed portion shall include the operator control levers, pressure YES □ NO □ control systems and foam equipment. Comments: ____________________________________________________________________ ___________________________________________________________________________________ A removable panel shall be installed just above the pump house walkway for YES □ NO □ additional service access to the pump. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Pump house, road and curb side access panels shall hinge-up with positive YES □ NO □ supports in order to accommodate maintenance and repair. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump house compartment will have a protective bottom heat pan with quick YES □ NO □ removal fasteners. The heat pan shall be as effective as possible, with front and rear vertical panels extending up to and between the frame rails for effective heat retention. The heat pan shall be inspected by the fire department to insure an acceptable fit. A poor fitting enclosure shall be rejected. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The pump house compartment will be heated by two (2) fan forced engine coolant YES □ NO □ Heaters ( min 30,000 btu ea) mounted internally at lowest level of the pump compartment. No exceptions Comments: ____________________________________________________________________ ___________________________________________________________________________________
13
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Fire Pump & Plumbing Controls The apparatus shall be equipped with a fire service rated single stage YES □ NO □ centrifugal PTO Fire Pump. Minimum rated pumping capacity shall be 1250 US GPM at 150 psi. The pump shall be by Waterous, the model# CXSPA. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a Waterous Pump Over-Heat Protection System installed, YES □ NO □ To prevent the pump from over-heating. Comments: ____________________________________________________________________ ___________________________________________________________________________________ A Fire Research panel mounted pressure governor shall be supplied. YES □ NO □ The model# shall be PBA404-D00. An audible alarm shall be included with the pressure governor. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Factory preset intake relief valve @ 120 psi (field changeable). YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ A rotary vane Oil-less - positive displacement 12 VDC primer pump shall be supplied. YES □ NO □ The primer pump shall be by Waterous, the model# VPOS. A Waterous vacuum activated priming valve shall be included. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be one (1) primer selector valve installed. This selector valve shall allow YES □ NO □ for priming the pump or the 6" suction hose up to a closed intake valve, with the main pump primer. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be two (2) bleeder valves installed, to bleed air from the 6" valved inlets, YES □ NO □ when a positive pressure supply of water is provided to that inlet. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Two (2) 6” (150mm) NH master intakes. YES □ NO □ One each located road and curb side. Long handle chrome caps to be supplied. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Two (2) 6.0" Electric Butterfly valves (Elkhart Brass) shall be installed at the YES □ NO □ Driver & Officer-side intakes. The electric valve controllers shall be installed at the sides of the pump operators Panel. Comments: ____________________________________________________________________ ___________________________________________________________________________________
14
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Two (2) 2 ½”(65mm) WCT intakes c/w bleed valve. YES □ NO □ One each located road and curb side. Operation of valves shall be at the pump operators panel. Valves shall be fully enclosed in pump compartment. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 3.0" Tank to pump supply valve/line. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) Tank supply check valve. YES □ NO □ Comments: ____________________________________________________________________ One (1) 2” (50mm) tank fill. The fill hose shall be 2” high-pressure flexible piping. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 2” (50mm) direct tank fill. The fill hose shall be 2” high-pressure flexible YES □ NO □ piping. The valve shall be 2” with the lever at the operators panel. A 2.5” female WCT inlet swivel & plug shall be installed at the inlet located on the officer-side. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Two (2) 1 ½” (38mm) NPSH cross-lay discharges c/w 2” plumbing. YES □ NO □ Cross-lays shall be accessible and useable from both sides. Cross-lays to hold a minimum 200 feet of 1 ¾” fire hose each. Crosslays shall be foam capable. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 2 ½” (65mm) WCT discharge road side c/w drain valves & YES □ NO □ 2 ½” (65mm) WCT cap. Cap to be chained to panel. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 2 ½” (65mm) WCT discharge curb side c/w drain valves & YES □ NO □ 2 ½” (65mm) WCT cap. Cap to be chained to panel. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 2 ½” (65mm) WCT discharge upper hose bed pre-connect YES □ NO □ c/w drain valve . To be Foam Capable. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 4” (100mm) Storz discharge curb side w/ 30 deg droop, YES □ NO □ 4” stortz adapter, and valve with slo-cloz actuator. C/w drain valve and 4” (100 mm ) Storz cap. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) 2 ½” front bumper monitor supply line c/w 2.5” supply plumbing. YES NO Plumbing shall be combination of stainless steel and high-pressure flex hose. A ¾” auto-drain valve shall be included to drain hose automatically when pressure drops below 8 psi. Comments: ____________________________________________________________________ ___________________________________________________________________________________ 15
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 One (1) 1.5” hose-reel supply line shall be provided. The valve actuator shall be YES □ NO □ at the pump operator panel. A blow-out air line shall be plumbed from the chassis air tanks to allow the water in the hose to be discharged to prevent freezing. A pressure protection valve shall be included. Air valve to be at the pump operators panel. To be foam capable. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be an electric rewind booster hose reel installed behind the YES □ NO □ Officer-side back-door running boards. 100’ of 1” rubber hose shall be included w/ Fog/stream nozzle. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All 2.5" discharges shall be chrome plated with a 30 degree droop. YES □ NO □ The rocker caps and rocker plugs will also be chrome plated. All caps and plugs shall be secured to apparatus. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Each discharge shall be supplied with a ¾” bleeder valve assembly. YES □ NO □ The drain shall be controlled with a quarter-turn valve on the side pump panel. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All valves will be Elkhart or Akron, quarter turn, self-locking ball valves. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ All discharges and intakes valves, gauges and meters shall have large, YES □ NO □ colour coded and descriptive tags. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All valve control handles shall be of a top-control lever system. YES □ NO □ All valve controls shall utilize cables, which shall be push-pull with a 100lb push & 400lb pull rating. no exceptions Comments: ____________________________________________________________________ ___________________________________________________________________________________ A master drain shall drain all remaining pump components from their lowest YES □ NO □ points. Located so that no interference occurs with other installed components. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All plumbing shall consist of SCH10 stainless steel pipe and fittings, or fire YES □ NO □ apparatus high-pressure flexible piping. No Exceptions. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All plumbing and valves shall be sufficiently sized to accommodate proper YES □ NO □ flows through the various intakes and discharges. Comments: ____________________________________________________________________ ___________________________________________________________________________________
16
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 One (1) 4.5" Master pressure and One (1) 4.5" Compound gauge. Dual scale. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Each discharge shall include a dual scale – sub zero - 2.5” diameter YES □ NO □ liquid-filled pressure gauge mounted at the pump panel positioned so as to correlate with the discharge control. Comments: _________________________________________________________________________ ___________________________________________________________________________________ A Fire Research Water tank level gauge shall be supplied. YES □ NO □ The model# shall be WLA200-A00. Comments: ____________________________________________________________________ ___________________________________________________________________________________ A Fire Research Foam tank level gauge shall be supplied. YES □ NO □ The model# shall be WLA260-A01. Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) Fire Research mini tank level gauge shall be installed on the YES □ NO □ cab console for the water tanks. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a remote tank level light driver supplied with the tank level gauge YES □ NO □ system. The driver shall power three (3) Whelen PSTANK led tank level lights. One light shall be installed on the driver-side, one on the officer-side and one at the rear of the apparatus. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Auxiliary engine cooler valve. Operates a shell & tube type heat exchanger. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Pump bypass valve YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Master gauge test ports YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Audible and visual alarm for engine oil pressure and coolant temperature YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ A Waterous Aquis 2.5 Electronic Direct Injection Foam System shall be provided. YES □ NO □ Comments: ____________________________________________________________________ A ¾” foam supply line shall be installed from the tank to the proportioner. YES □ NO □ The supply line shall include a ¾” supply valve and 3/4” “Y” strainer. A ½” bypass valve and hose shall be included. Comments: ____________________________________________________________________ ___________________________________________________________________________________ 17
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 The foam manifold shall be sufficiently sized to accommodate proper YES □ NO □ flows through the discharges. The following discharges shall be foam capable: • Crosslay #1 & Crosslay #2 • 2.5” hose bed pre-connect • Hose reel • Front Bumper Monitor Comments: ____________________________________________________________________ ___________________________________________________________________________________ Foam operation and proportioning shall be controlled at the pump panel. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ APPARATUS BODY The body shall be of a modular type construction, independent of the chassis, YES □ NO □ pump house and water tank. Aluminum extrusions shall be used to construct the body. The material used shall be Type 5052-H32 aluminum, with a thickness of 3/16". All compartment floors shall be type 5052-H32 aluminum, thickness to be 3/16". A minimum of two (2) 3/16" aluminum channels shall be welded, spaced evenly below each compartment floor for support purposes. No Exceptions. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The manufacturer shall clearly state the compartment dimensions on the YES □ NO □ drawing they provide and shall list all dimensions including width, height and depth. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The manufacturer shall provide a drawing of each of the following views, YES □ NO □ Front, Rear, Top and Both Sides. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Road side compartment (L1) ahead of body wheel. YES □ NO □ Compartment to measure approx. 50" wide x 24" deep x 66" high. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Road side compartment (L2) over wheel well. YES □ NO □ Compartment to measure approx. 56" wide x 24" deep x 40" high. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Road side compartments (L3) behind body wheel. YES □ NO □ Compartment to measure approx. 40" wide x 24" deep x 66" high. This compartment equipped with 500 lb capacity rollout tray with spare bottle storage for (8) bottles. Comments: ____________________________________________________________________ ___________________________________________________________________________________
18
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Officer side compartments (R1) ahead of body wheel. YES □ NO □ Compartment to measure approx. 50" wide x 24" deep x 66" high. This compartment equipped with 500lb capacity roll-out tray for installation of a generator. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Officer side compartments (R2/R3) over wheel well. YES □ NO □ Compartments to measure approx. 18" wide x 24" deep x 40" high. Ladder rack to be positioned between these two compartments. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Officer side compartment (R4) behind body wheel. YES □ NO □ Compartment to measure approx. 40" wide x 24" deep x 66" high. This compartment equipped with 500lb capacity roll-out tray. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All compartment dimensions are outside of compartment. YES □ NO □ There shall be no rear compartment. Body to be Rescue style with full-depth compartments. Rectangular tank to extend to back of body. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Roll-up doors shall be provided on all exterior body compartments, with the exception YES □ NO □ compartments R2 & R3. These compartments shall have hinged doors. Rollup Door Brand to be Amdor w/ full height Led Luma-bar Strip light on both sides of door. All door switches shall be negative magnetic style, no exceptions Comments: ____________________________________________________________________ ___________________________________________________________________________________ All compartments shall be free of any protrusion that will inhibit equipment YES □ NO □ loading and storage space. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All storage compartments shall be vented, with filters included. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ All storage compartments shall weatherproof and dust-proof. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Body Fenders shall be stainless steel and shall have stainless steel fenderetts YES □ NO □ attached to the fender skirts. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All exterior storage compartments and doors on the apparatus YES □ NO □ shall be complete with a door-ajar switch that is wired to the flashing warning light at cab dash. Comments: ____________________________________________________________________ ___________________________________________________________________________________
19
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Full height compartments shall have adjustable tracking installed. YES □ NO □ Tracking will allow for adjustment and additional shelving. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Body compartments shall include a total of seven (7) adjustable shelves YES □ NO □ located as follows: L1 2 shelves L2 1 shelf L3 1 shelf R1 2 shelves R4 1 shelf Comments: ____________________________________________________________________ ___________________________________________________________________________________ Body compartments and shelving shall include vinyl matting. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ Sufficient handholds and steps shall be provided to accommodate reaching the YES □ NO □ upper portions of the pump house body, and all top mounted equipment. Purchaser shall approve Comments: ____________________________________________________________________ ___________________________________________________________________________________ The rear step shall accommodate operations from the rear of the unit. YES □ NO □ A heavy duty bolt on type rear step shall be installed. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Proper handholds and steps shall be provided at the rear of the apparatus. YES □ NO □ Purchaser to approve. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The hose-bed shall be free of protrusions and must allow ventilation under YES □ NO □ the loaded hose. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The hose-bed shall have one (1) adjustable divider. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ A hose bed tarp that covers and secures the entire rear hose bed - complete YES □ NO □ with velcro shall be installed. The tarp shall feature 2" x 1/4" aluminum flat bars bonded/sown crosswise at 24" intervals for added support. no exceptions Comments: ___________________________________________________________________ __________________________________________________________________________________ A checkerplate hinge-up cover shall be installed over the 2 crosslays. YES □ NO □ A drop-down tarp shall be included on each side. Comments: ___________________________________________________________________ __________________________________________________________________________________ 20
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Three (3) guide rollers, one (1) horizontal and two (2) vertical shall be provided YES □ NO □ on each side of the crosslay hose beds. Comments: ___________________________________________________________________ __________________________________________________________________________________ The body shall accommodate a rectangular 1000 IMP-GAL CO-Poly water tank. YES □ NO □ The tank shall be replaceable and easily removed from the body. Integral baffles shall be included, with a maximum un-baffled distance of 24" in any horizontal direction. Tank shall be NFPA compliant. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The frame that the water tank sits on, shall have 1/2" rubber strips bonded to it. YES □ NO □ This shall provide a softer cushion for the tank to ride on. Comments: ____________________________________________________________________ ___________________________________________________________________________________ A CO-Poly foam tank shall be supplied. The capacity 25 IMP Gallons. YES □ NO □ The tank shall be replaceable, easily removed from the body, and shall not be part of the water tank. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The foam tank shall be equipped with a flush-fit, maintenance-free YES □ NO □ pressure / vacuum vent. Comments: ____________________________________________________________________ The tank shall have a manufacturer’s lifetime guarantee against YES □ NO □ failure or damage from defects and corrosion. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The water tank shall have a top mounted fill tower with screen and lid YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ A tank drain of at least 1 ½” (38mm) shall be located in an easily YES □ NO □ accessible location. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The water and foam fill towers shall be positioned to allow maximum YES □ NO □ storage space at the body top. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Electrical System The manufacturer shall design the wiring system for the apparatus in YES □ NO □ accordance with the latest edition of N.F.P.A – 1901 and/or Society of Automotive Engineers (SAE) and Canadian Motor Vehicle Safety Standards (CMVSS). Comments: ____________________________________________________________________ ___________________________________________________________________________________ 21
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 The manufacturer shall design the electrical system utilizing Diamond Logic YES □ NO □ by International. No Exceptions. The chassis computer shall be programmed to provide Apparatus Electrical Control as required. The following program features shall be included: • opening any chassis door shall turn-on ground/step lights • shifting transmission to reverse shall turn-on back lower lights and upper scene lights • pump engage circuit shall be electric (diamond logic) cab dash rocker switch to be blue in color • a remote pump engage switch shall be placed at the pump operators panel • pump shall not engage unless trans is in neutral and park brake is engaged (pump-panel switch) • pump shall automatically dis-engage when speed reaches 30 km • scene & ground lights shall turn-off when speed reaches 30 kms • engaging park brake shall turn-off front facing clear lights if flashing at such time • master warning switch to be supplied, color to be red • pump house heater switch to be rocker, color to be yellow Comments: ____________________________________________________________________ ___________________________________________________________________________________ All 12 volt electrical wiring installed by the fire apparatus manufacturer YES □ NO □ shall have the carrying capacity commensurate with the anticipated maximum circuit loading. The manufacturer shall determine circuit loads and design the system to accommodate these loads with appropriate circuit routings and relays. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The wiring shall be readily accessible and be protected against heat, water YES □ NO □ and physical injury. The wiring shall be properly protected in an automotive high temperature type loom. Comments: ____________________________________________________________________ __________________________________________________________________________________ All wiring harnesses shall be properly secured and routed. All passages YES □ NO □ required for routing shall have grommets and sealed as required. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All wiring harnesses shall be function / number / color-coded every 3". YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ All circuit breakers shall be protected by bolt type, automatic reset circuit YES □ NO □ breakers. All breakers shall be properly sized to the circuit load. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The electrical system shall be of a single battery type installation. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ A master switch will control all 12 volt DC electrical power in the vehicle. YES □ NO □ This switch will be easily accessible from the driver’s door area and from the driver’s seat. An external "Master Battery On" green light to be installed at the driver cab skirt. Comments: ____________________________________________________________________ ___________________________________________________________________________________ 22
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 A 12 Volt Battery charger/conditioner w/ battery charge bar graph and YES □ NO □ Air Brake Air Supply Pump shall be installed and wired into an external auto-eject receptacle located at road side – cab running board. The charger/air pump shall be a Kussmaul Pump Plus System, part# 091-9-1000-S-KIT. Comments: ____________________________________________________________________ ___________________________________________________________________________________ A 5000 watt Xantrex inverter shall be installed beneath the crew seat. YES □ NO □ Duplex receptacles shall be wired to the following locations: • one (1) beside the cab console • one (1) inside and high in compartment L3 • one (1) inside and high in compartment R4 Comments: ____________________________________________________________________ ___________________________________________________________________________________ All light switches shall be mounted so that both the Driver and Officer YES □ NO □ can easily reach the equipment. Switch panel shall be of Diamond Logic. Comments: ____________________________________________________________________ ___________________________________________________________________________________ The engine compartment shall have two (2) large bright lights with clear YES □ NO □ lenses. Comments:_____________________________________________________________________________ ___________________________________________________________________________ All steps shall have adequate lighting. One cab switch will control the lights. YES □ NO □ Comments:_____________________________________________________________________________ ___________________________________________________________________________ A total of eight (8) Under Body LED step lights shall be provided. YES □ NO □ The lights shall be Fire Research part# LED200-18 (18"long) . Comments:_____________________________________________________________________________ ___________________________________________________________________________ Both exterior pump panels shall have one (1) Fire Research part# YES □ NO □ LED200-A36 (36" long) Led strip light installed each side. A local switch at the operator’s panel will control the lights. Comments:_____________________________________________________________________________ ___________________________________________________________________________ The pump operators panel shall have one (1) Fire Research part# YES □ NO □ LED200-A63 (63"long) Led strip light installed. A local switch at the operator’s panel will control the lights. Comments:_____________________________________________________________________________ ___________________________________________________________________________ Two (2) Fire Research Led Scenelights shall be mounted at body upper rear. YES □ NO □ The model# shall be FCA570-Q20. One cab switch shall control the lights. These lights shall automatically turn-on when the transmission is shifted to reverse. Comments:_____________________________________________________________________________ ___________________________________________________________________________
23
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 Two (2) telescopic LED Scene lights shall be provided. They shall be Fire Research YES □ NO □ part# FCA530-Q20, consisting of side mount, push-up poles with 12 volt LED Lightheads. Scene lights shall be mounted; one road side and one curb side at the front edge of pump-house. Comments:_____________________________________________________________________________ ___________________________________________________________________________ All vehicle (chassis and body) lighting shall meet D.O.T., C.M.V.S.S. and Provincial standards.
YES □
NO □
Comments:_____________________________________________________________________________ ___________________________________________________________________________
Emergency Vehicle Lighting, Sirens & Controls Vehicle emergency warning lights shall conform to the latest edition of YES □ NO □ NFPA 1901. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All warning and flood lights shall be controlled from the cab. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ The Lightbar shall be LED, Whelen model# FN60VLED. Led alley lights shall be YES □ NO □ provided on each side of the Lightbar. A total of four (4) front facing red led flashers, two (2) white led flashers four (4) corner led flashers shall be provided. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be supplied two (2) Rear Beacons, LED, Whelen model# L31HRFN, YES □ NO □ one (1) each side of the body at the top. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be supplied eight (8) M6, Red LED lightheads, on the lower level of the YES □ NO □ apparatus, in the following locations: (2) at the front grille (2) at the chassis fenders (2) at the body fenders chrome flanges shall be included with the above. (2) at the back of the body. These shall be installed in Whelen CAST4V Housings. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be supplied Whelen M6 Series, Brake/Tail/Turn, LED lightheads, on the YES □ NO □ back of the apparatus: (2) M6BTT - Brake/Tail (2) M6BUW - Back-up (2) M6T - Amber Turn Arrow (2) M6FCV4 Vertical Housings. Comments: ____________________________________________________________________ ___________________________________________________________________________________ 24
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 There shall be installed in the cab, a siren amplifier and control centre. YES □ NO □ The siren shall have Wail, Yelp, Piercer and Hi-lo tones. The siren shall have provision for public address. The siren shall have activation of tones by the steering wheel horn button. The Siren shall be Whelen part# 295SLSA1. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be one (1) 100 watt heavy duty weatherproof speaker mounted in the YES □ NO □ front bumper area. The siren speaker must have a free and clear projection to the front of the vehicle. It shall be Whelen Part# SA122FMP. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a momentary switch installed at the pump panel to activate YES □ NO □ the siren system. Comments: ____________________________________________________________________ ___________________________________________________________________________________ All emergency lighting and siren controls shall be mounted so both the Driver YES □ NO □ and Officer can reach the equipment. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Two (2) mobile radio antennas shall be mounted free and clear of interference YES □ NO □ from electrical components at the highest practical location on the chassis cab roof. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be installed an aluminum console in the interior of the cab, between YES □ NO □ The seats. The console shall be painted with the cover having arborite over-lay to prevent surface scratching. Comments: ___________________________________________________________________ ___________________________________________________________________________________ FINISHING AND PAINTING The painting process shall be done in accordance with good automotive YES □ NO □ practices using acrylic urethane enamel paint and a qualified painting process. Comments: _____________________________________________________________________ ___________________________________________________________________________________ All seams that are not 100% welded shall be sealed and caulked inside and YES □ NO □ outside before the final finish paint is applied. Comments: _____________________________________________________________________ ___________________________________________________________________________________ The interior of all compartments of the body shall be sealed and caulked. YES □ NO □ All compartments are to be painted with a textured abrasion resistant interior coating. Color to be GREY. Comments: ____________________________________________________________________ ___________________________________________________________________________________
25
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 The underside of the body shall be undercoated with a durable corrosion YES □ NO □ resistant coating. Comments: ____________________________________________________________________ ___________________________________________________________________________________ Colors on body shall match the cab. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a 4” wide reflective striping applied to the apparatus. YES □ NO □ Single stripe, white in color. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a reflective warning stripping applied inside all cab YES □ NO □ and body doors to warn when door is open. Single stripe, white in color. Comments: ____________________________________________________________________ ___________________________________________________________________________________ MISC EQUIPMENT Two (2) 6 inch NH x 10 foot lightweight suction hose for master intakes. YES □ NO □ Storage brackets shall be provided for the 6.0" suction hose on the ladder rack. Comments: __________________________________________________________________ One (1) 6 inch (150mm) NH floating strainer shall be provided. YES □ NO □ Comments: __________________________________________________________________ ___________________________________________________________________________________ A Zico hydraulic ladder rack, part# HLAS shall be installed above the officer-side YES □ NO □ wheel compartment. The ladder rack (when not in stowed position) shall be wired to the "do not move apparatus" indicator light at the cab dash panel. Comments: __________________________________________________________________ ___________________________________________________________________________________ One (1) set of wheel chocks. Heavy duty construction. YES □ NO □ Comments: __________________________________________________________________ ___________________________________________________________________________________ Two (2) sets of wrench holders with wrenches, one set mounted each side YES □ NO □ Comments: __________________________________________________________________ ___________________________________________________________________________________ A 20" extended front bumper shall be provided. The top and both sides YES □ NO □ of the bumper extension shall be enclosed with polished aluminum checkerplate. Comments: _____________________________________________________________ ___________________________________________________________________________________
26
R. M. OF BLANSHARD – REQUEST FOR FIRE SERVICE PUMPER 2013 There shall be supplied and installed at the front extended bumper, an Elkhart Brass YES □ NO □ EXM Remote Controlled Monitor. The package shall include the following: model 7100 Sidewinder EXM Monitor model 7030 joystick controller model 7070 OEM interface kit model 7150 quick-disconnect adapter model 6000-200E 200 GPM nozzle w/ flow settings 15/30/45/60/95/125/150/200 Comments: __________________________________________________________________ ___________________________________________________________________________________ There shall be installed behind the officer-side back crew door running boards, YES □ NO □ an Akron Brass Electric Rewind Hose Reel. The model# shall be ERWB-16-28. Chrome plated spool & rollers shall be provided, model# ERWB-GR-16. 100' of 1.0" rubber hose shall be included. One (1) nozzle and nozzle holder shall be included. A hose reel blow-out line shall be plumbed from the chassis air compressor to the hose reel supply line. Comments: __________________________________________________________________ ___________________________________________________________________________________ There shall be five (5) helmet holders installed in a location on the truck as YES □ NO □ directed by the fire department. Comments: ____________________________________________________________________ ___________________________________________________________________________________ There shall be a Vehicle Data Recorder installed on the apparatus. The display shall be mounted On the cover of the center console. YES □ NO □ Comments: ____________________________________________________________________ ___________________________________________________________________________________ One (1) Electronic Tire Pressure Monitor System shall be provided. YES □ NO □ The system shall include valve stem sensors for each Tire. Comments: ____________________________________________________________________ ___________________________________________________________________________________
27