Preview only show first 10 pages with watermark. For full document please download

Biomedical

   EMBED


Share

Transcript

2016 -09 I Biomedical P 2016 Biomedical Group Profile Factories Around the World America 3 1 2 1 12260 Europe 4 1 2 15100 Africa 4 2520 Established in 1984, Haier is the world's No. 1 major appliance brand. It has transformed from an enterprise that manufactures household appliances to a platform that incubates entrepreneurs for the whole society. In the Internet age, Haier aims to become a Networked Enterprise which overturns its self-contained enclosed system and fits into the Internet as a node that can connect various resources, with a view to building post-e-commerce ecosystems based on user value interaction for co-creation and winning together to add value for all stakeholders. On Haier's entrepreneurial platform there are two listed companies: Qingdao Haier (600690.SH) and Haier Electronics (01169.HK). The main focus of Haier Group is the innovation on three platforms: white household appliance, investment incubation and finance holding platforms. Through its exploration into the Internet Model, Haier Group has achieved steady growth. In 2015, Haier achieved a global turnover of 188.7 billion yuan with a compound growth rate of 6% over the past decade, and a total profit of 18 billion yuan with a 20% year-on-year growth rate and 30% compound growth rate over the past decade, 5 times that in revenue. The online trade volume reached 157.7 billion yuan, a year-on-year growth of nearly 200%. With the rapid development of Internet finance, the trade volume on the Internet platform totaled over 70 billion yuan. By the end of 2015, Haier's platforms have attracted over 4,700 first-rate external resources, 3 billion yuan of VC fund, 1,330 VC institutions and 103 incubators, setting the stage for 1,160 projects. Over 3,800 node microenterprises and nearly one million microstores on Haier's platforms are socializing their capital and human resources. More than 100 microenterprises boast an annual revenue of over 100 million yuan, and 22 have introduced VC, and 12 are valued at over 100 million yuan. Due to Haier’s transformation through decentralization, disintermediation and removing the “insulated wall”, the employees have decreased from the highest 110,000 to less than 60,000, but Haier's platforms have offered over 1 million jobs for the whole society. Haier's model innovation has not only been acknowledged by authoritative experts, but also verified by practical tests. In 2011, Haier announced the acquisition of Sanyo's white goods business in Japan and Southeast Asia. In 2012, Haier completed the purchase of New Zealand’s iconic home appliances company Fisher & Paykel Appliances (F&P). On January 15, 2016, Haier's globalization opened up a "historic page" - Haier signed a memorandum of strategic cooperation with GE to integrate GE's home appliances business, which set not only a new example for business cooperation between large Chinese and US enterprises, but also a new alliance model that rises above price-based trading. Haier's global brands include Haier, Casarte, Goodaymart, AQUA, Fisher & Paykel and Leader, which bring best user experience from different fields. 01 East Europe 1 2 2390 West Asia 2 2380 Medit 1 1 3 2660 South Asia 1 1 6 3560 China 42 12 3 35190 5 East Asia 3 2 1 1550 Southeast Asia 5 3 2670 1 Australia 1 610 Worldwide Network Trading Company R&D Center Manufactory Industry Park Sales Network Overseas 19 5 24 4 45800 Global 61 8 29 16 80990 Biomedical Founded in 1998, Haier Biomedical is based in China. We design, manufacture and market laboratory equipment for the global market. Our products are designed to enable scientific researchers across the globe to perform research projects and to produce pharmaceutical products. Our products include ultra-low temperature freezers, blood banks, pharmacy refrigerators, ice-lined vaccine refrigerators, laboratory freezers, washers, fume hoods, biosafety cabinets and other types of equipment for the laboratory and medical applications. Installations can be found in blood banks, hospitals, epidemic prevention services, universities, pharmaceutical manufacturers, and national laboratories. The successful growth of our business drove a continuous development of our manufacturing ability. Along with many state of the arts manufacturing equipment, we added a new factory in 2013 to meet the increasing demand of our customers. Headquartered in Qingdao, China, our company is a part of Haier Group Company which is highly ranked as one of the key global manufacturers of durable goods. In addition to certification with ISO9001 quality system, ISO14001 environment protection system, and ISO13485:2003 quality system, the company has been awarded the People’s Republic of China Medical Device Manufacturing Enterprise License, People’s Republic of China Medical Device Registration Record, and Record of Medical Device For Medical Device Category A,B and C from the State Food and Drug Administration. Our research and development team consists of highly qualified and selective professionals specialized in refrigeration technology, control technology, remote sensing, sample protection and handling, and networking technology. Our business strategy and technological advancement have been very effective since the founding of the company. We now have shipped products to clients in over 100 countries. 02 Milestones & Awards Premium Products ULT Freezer 2015 In 2015,more than 3500 vaccine refrigerators have been delivered to Middle East and Africa. Haier walk-in cold room has successfully won the bidding aid to Afghanistan from WHO,aid to Philippines,Syria and Jordan from UNCIEF. 2013 2011 2009 2007 20 • World Leading Energy-efficient Haier Biomedical inaugurated a new state-of –the art manufacturing facilities for high quality production of medical cold chain products. The world most energy-saving ULT Freezer was launched by Haier Bio-Medical. 1000 units HTC-60 were delivered to Ethiopia. Haier successfully provided MOH tender of Uzbekistan Sudan, Tanzania, Uganda and Madagascar etc., which is a new important milestone to develop the African market. Haier won MOH tender of blood bank refrigerators and -86°C ULT freezers in Russia market. 2014 • Hrdrocarbon Refrigeration System • Reliable Sample Protection • Excellent Insulation Performance • Multi Function Alarms 2012 DW-86L728J/578J 23 ULT Freezer • LCD Touch Screen • Unique Inventory Management System Haier won the tender "Third National HIV/AIDS Control Project (NACP - III)” from India ministry of Health and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers. 2010 Haier Medical successfully won the bid of 20,930 units vaccine refrigerator from UNOPS (United Nations Program India Purchasing Agency). World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116. • World Largest Capacity • Global Most Energy-efficient • Multi Function Alarms DW-86L959/729 2008 Haier Blood Transportation Box – HXC-80, won the bid of UNOPS India/NACO/BT B/35/2008, from India National AIDS Control Organization. Biomedical Freezer 41 • Double Door Design • Double Capillary Tube • Improved Door Seal Haier won the government procurement tender for International Assistance Program to Cuba from China. 2006 Haier became the first China based company to be certified to ISO13485:2003. 2005 Haier -150°C cryogenic freezer launched into the market – Haier medical and laboratory freezers coverd most of the temperature range required by market. 1998 • Multi Function Alarms DW-40L508/348 2004 Haier was awarded with an order from World Health Organization (WHO) and entered into the international market. • Label Drawers Combined Refrigerator and Freezer 49 • Refrigerator & Freezer Combination • Independent Display for Refrigerator and Freezer • Drawer with Plexiglass Dividers The Deep Freezer(-40°C) came out, Haier entered into Medical and Laboratory Industry. • Multi Function Alarms HYCD-282/282A 03 04 2016 NEW PRODUCTS Biomedical Biomedical Premium Products Pharmacy Refrigerator Premium Products Solar Direct Drive Vaccine Refrigerator 55 • New Appearance, more intelligent • Solar Drive,Green and Environment Friendly • USB Data Port • LCD Temperature Display • Electrically Heated Glass Door • Lockable Door Design • Optional Printer • Microprocessor Control 77 • Adjustable Shelves HTC-60H HYC-390/290 Under-counter Pharmacy Refrigerator Solar Direct Drive Combined Refrigerator/Freezer 57 79 • Solar Drive,Green and Environment Friendly • Under-counter Models • Double Function: Storing Vaccines and Freezing Icepacks • Electrically Heated Glass Door • High/Low Temperature and Sensor Error Alarms • Optimized Refrigeration System • Lockable Door Design • Drawers And Shelves Storage • Audible And Visible Alarm HTCD-160 HYC-118A/118 63 Blood Bank Refrigerator Biological Safety Cabniet 91 • EN12469 & NSF Certificated • Consistent Cabinet Temperature 4±1°C • Patent Intelligent Constant Air Velocity • Microprocessor Control • Low Noise Safety Energy-saving Mode • Auto Defrost • Unique Drop-down Front Glass Window • Optional Drawers or Blood Baskets • Patented Technology of Air Flow Recircuiation • Multi Function Alarms HR1200-IIA2 HXC-358B Clean Bench 75 97 • WHO/PQS Approved • High Efficiency ULPA Filter • Large Capacity • UV Lamp One-key Preset • CFC-Free • Patented Technology of Pre-cleaning Function • Stainless Steel Interior • 304 Stainless Operation Platform • Ice-packs Built In HCB-900V/HCB-1300V HBC-340/110 05 06 2016 NEW PRODUCTS Ice Lined Refrigerator Preservation Cryo Freezer ULT Freezer Consumables Biomedical Freezer Combined Refrigerator and Freezer Pharmacy Refrigerator Blood Bank Refrigerator 11 13 33 39 49 53 63 WHO/PQS Certificated Vaccine & Icepack Freezer Ice-Lined Refrigerator SDD Vaccine Refrigerator Walk-In Cold/Freezer Room 73 75 77 87 Laboratory Equipment 91 97 101 107 109 113 Models Line-up Models Line-up 07 08 119 2016 NEW PRODUCTS Biological Safety Cabinet Clean Bench Liquid Nitrogen Container CO2 Incubator Lab Centrifuge Water Purification System Cryo Freezer & ULT Freezer 09 10 -150°C Cryo Freezer Liquid Nitrogen Preservation System in Cryo Freezer LN2 Freezer System(-196 °C) DW-150W200 Model Cabinet Type Technical Data -150°C Cryo freezer, developed by Haier Medical and Laboratory Products Co.,Ltd provides a safer, more convenient and economical alternative long term storage method than LN2 refrigeration systems. By providing a storage environment that is about 20°C colder than the water recrystallization temperature, the freezer is suitable for storage of a variety of biological samples such as virus, erythrocytes, leukocytes, cutis, skeleton, sperm, oceanic products, special test materials and even electronic products for testing. It can be installed in institutions including blood banks, hospitals, epidemic prevention services, research institutes, and research laboratories. Chest Climate Class N Cooling Type Direct cooling Defrost Mode Manual Refrigerant Performance Control HFC Cooling performance(°C) -150 Temperature Range(°C ) -126~-150 Controller Microprocessor Display LED Power Supply(V/Hz) Temperature Control • Microprocessor control: Large LED display features a clear cabinet temperature display at an easy viewing angle and allows an adjustable range of -126°C to -150°C Refrigeration System • • • • Safety Control System • Alarm system: User programmable high and low temperature alarm set points, power failure, sensor error, extreme voltage, hot condenser, and extremely high ambient • Alarm types: audible buzzer and visible flashing • Protection functions: Settable pass codes for control panel, start-up delay, voltage compensation system • Properly grounded Optimized single stage refrigeration system Hermetically sealed system Environmentally safe refrigerants Permanently lubricated fan systems Electrical Data Power(W) 2800 Electrical Current(A) Functions Accessories 11 315/385(kg) 695.0/849.5(lbs) Interior Dimension(W*D*H) 667*462*650(mm) 26.3*18.2*25.6(in) Exterior Dimension(W*D*H) 1670*850*1060(mm) 65.7*33.5*41.7(in) Packing Dimension(W*D*H) 1695*940*1240(mm) 66.7*37*48.8(in) Container load (20'/40'/40'H) 6/13/13 High/Low Temperature Y Remote Alarm Y Hot Condenser Y Power Failure Y High/Low Voltage Y Sensor Error Y Low Battery Y N/A High Ambient Temp Large LED display for easy viewing Ambient range of 10 °C to 30°C LN2 back up system compatible Remote monitoring Smart condenser fans for energy saving 9 200/7.1 Net/Gross Weight(approx) Other Features • • • • • 380/50 Capacity(L/Cu.Ft) Dimensions Cryo Freezer(-140°C) Caster Y Foot Y Test Hole Y/1 Shelves/Inner doors -/2 12 Cryo Freezer & ULT Freezer Biomedical -86°C ULT Freezer Biomedical -86°C ULT Freezer Operating status display 4 Individual Removable Foam Inner Doors • 4 individual inner doors can be opened independently to minimize frost buildup inside the chamber. • Unique door seal design for the minimum loss of cold temperature during a door opening. • Compatibility with existing racking system from competitors. • Stainless Steel handle to ensure the door open conveniently even in the case of frost. Display for working temperature, setting temperature, high-alarming temperature, low-alarming temperature, password setting, and codes error Eye-level controls for quick and easy programming and viewing Audio/visual alarm Excellent Doors Seals Silencing sound alarm • 5 gasket seal , 4 seals for out door, 1 seal for inner door which provides maximum protection against thermal intrusion. Microprocessor control panel and digital display Malfunction detection Adjusting key Ambient temperature display Selecting function Voltage display Alarm Triggering Condition Alarm Circular- chart Recorder(Optional) • Front-mounted. • For independent temperature monitoring. DW-86L728J Pressure Equalization Port • Heated port with spring-assisted mechanism to prevent icing on the vent. • Allows the freezer door to be opened shortly after adding samples. High Temperature Temperature reaches the warm alarm limit Low Temperature Temperature reaches the low alarm limit Power Failure Door Ajar Equipment loses power Door open period exceed setting time,the setting time adjustable within 0 to 20 minutes E0.Ambient sensor fails E1.Condenser sensor fails Sensor Error E2.Main cabinet temperature control sensor fails Low Battery High Efficiency Refrigeration Components • Industrial grade hermetically sealed compressors, ultra low noise under cascade cooling system. • High efficiency coalescent oil separator ensures no oil entering. • Energy efficient fan design. • Unique CH refrigeration system is optimized to provide maximum efficiency in even the most extreme ambient conditions. 13 Hot Condenser Two sample ports on back for temperature monitoring conveniently. Battery capacity runs low or battery switch is not turned on 1. Condensers filter element is clogged 2. Ambient temperature is too high High Ambient Temperature Ambient temperature exceeds 32°C 14 Cryo Freezer & ULT Freezer E3.Heat exchanger sensor fails E4.Heat exchanger temperature fails Performance and Features Biomedical Heat Exchange Circulation System Capillary Tube Capillary Tube Safety Installiation & Application • Malfunction alarms including high and low temperature, power failure, sensor error, clean -filter, and extremely high ambient • Capable of producing two types of alarm outputs: audible buzzer and visible flashing light • Multiple built-in system protection features including user-settable protection code for controls, user settable delay to start, voltage compensation system, and protection against extreme high voltages • Door open feature standard and USB port for temperature data downloading standard on upright models • Remote alarm contacts • Wide range operating voltage system from 185V to 260 V designed to allow units installed in areas with poor voltage condition • Suitable for 10°C to 32°C ambient temperature • Input voltage and ambient temperature shown simultaneously for ease of monitoring environmental conditions • Robust door latch designed for secure door closing • Compact casters for ease of maneuvering • Specialized refrigeration system design using whisper quiet fan and compressors • Freezer chassis designed to absorb vibration and sound Low sound level • Unique door seal design for the minimum loss of cold temperature during a door opening • High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability • Patented cabinet insulation system designed for optimal performance of cold storage temperature and minimal frost buildup • Unique design of independent insulated inner door systems for independent access of storage space to provide the maximum protection of stored samples Energy saving Key design features • Microprocessor-controlled system designed for controllable range of -40°C to -86°C for cabinet space with 1°C increment • Large LED display for cabinet temperature, set temperature, ambient temperature, and input voltage • Settable high temperature and low temperature alarms • Automatic clean-filter alarm and sensor error alert • Adjustable storage shelf height • Optional temperature recorder, storage racks and storage boxes 15 Evaporator Cascade Condenser Condenser Precondenser anti condensation High Stage Compressor Suction Accumlator Pressure Switch Low Stage Compressor Filter Dryer Oil Separator Filter • Filter for refrigerant to protect system from the water and other entering Capillary tube for high stage • High temperature refrigerants flow into the evaporator from the Capillary tube Capillary tube for low stage • Low temperature refrigerants flow into the evaporator from the Capillary tube High stage condenser • Extra-large air cooled condenser dissipates product heat content efficiently. Low stage Evaporator • The close contact design between the evaporating tube and the inner cabinet increases the heat conducting efficiency Ultra low noise compressor • Compressor provides reliable performance with ultra low noise • Specially designed low stage evaporator yields excellent temperature uniformity and recovery after loading and door opening. • Both high and low stage compressors are industrial grade hermetically sealed compressor designed for low temperature application. Sound level is extremely low. Heat exchanger system • Heat exchanger between the high and low temperature stage in the system Temprite oil separator • Temprite oil separator can effectively separate oil and water so as to improve the refrigeration performance 16 Cryo Freezer & ULT Freezer Field proven reliablity • Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber • Specialized control system design for a well-balanced operation of cascade refrigeration system • Positive field proven reliability record Filter Dryer CO2 Backup System Biomedical Advantage • • • • LN2 Backup System LN2 backup system is an emergency cooling device, when ULT freezer fails, LN2 backup system offers short-term protection until contents can be removed and repairs initiated. Its working principle is through controlling the solenoid valve installed in the cooling circuit, automatically injects LN2 to maintain temperature during prolonged power outage. The backup system with built-in rechargeable battery, it’ll continue to work normally when power failure. Small footprint, light and easy for installation User adjustable temperature setting Simple to program and operate Flexible – Can be installed on any ULT freezer, which has a port hole Safety • Liquid CO2 test button design allows end user to test the system is working • Low CO2 alarm system - alerts end user when liquid CO2 bottle is running out therefore insuring the safety of their samples Reliability • Stainless steel covering, more elegant • Stainless steel input pipe design, allows for flexibility and ease of cylinder positioning • Durable battery lasts up to 48 hours Technical Data Performance Control Electrical Data Model Cabinet Type Climate Class Cooling Type Refrigerant Cooling performance(°C) Temperature Range(°C) Controller Display Power Supply(V/HZ) Power(W) Electrical Current(A) Net/Gross Weight(approx) Dimensions Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H) Functions Accessories Others CO 2 Margin Insufficient Alarm Low Battery Alarm Sensor Error Alarm Main Power Off Alarm Charge Indicator CO 2 Injection Test Button Foot Certificate HBX-IC HBX-IB Horizontal N Direct cooling CO 2 -70 -40~-70 Thermostat LED 208~230/60 220~240/50 115/60 20 0.25 11.2/13.6(kg) 24.7/30(lbs) 200*400*160(mm) 7.8*15.7*6.3(in) 370*530*330(mm) 14.6*20.9*13(in) Y Y Y Y Y Y 4 CE UL Bright LED Display Front-mounted Control Panel “A proven solutions partner ”Marrow Donor Program(NMDP) Hundreds of -86 °C ultra low temperature freezer and the cold chain equipment monitoring and control system solution for NMDP. Haier water-cooled ULT Freezer in SAHMRI, Australia The first water-cooled ULT freezer project of Haier biomedical in overseas market and the products were highly evaluated “Haier water-cooled ULT freezer is the best in the world!" 17 18 LN2 Backup System Side Grille LN2 Backup System Biomedical ULT Freezer Features Linked switch design, which cuts off LN2 injection automatically when the door is opened, to ensure the safety of users. Over-charging protective circuit design, it is important for extending the service life of rechargeable battery. Portable design, light weight and easy to move, it is suitable for installation on the top of the freezer. Alarm functions, including low battery, sensor error, etc. This product is specially designed and manufactured for long term storage of various biological products, including viruses, germs, erythrocytes, leucocytes and cutis. Applications can be found in blood banks, hospitals, epidemic prevention services, and research institutes, laboratories in electronic and chemical plants, biological engineering institutes and marine fishery companies. Haier’s next generation ULT freezer DW-86L728J is particularly designed for energy savings. It consumes the least amount of energy for the class of large ULT freezers. This new model uses environmentally safe hydrocarbon refrigerants and high efficiency fan motors to maximize the cooling ability of the system and reduce energy consumption. While providing sample safety, the new freezer design makes energy savings possible for laboratories. Advantages Model HBX-IIA Cabinet Type Performance Control HBX-II Horizontal Climate Class N Cooling Type Direct cooling Refrigerant LN 2 Cooling performance(°C) -135 Temperature Range(°C) -99~-135 Controller Thermostat Display LED Power Supply(V/HZ) 208~230/60 115/60 220~240/50 Electrical Data Power(W) 20 Electrical Current(A) 0.15 15/17(kg) Net/Gross Weight(approx) Dimensions Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H) Functions Accessories Others World leading energy-efficient Hydrocarbon refrigeration system Slim cabinet design Reliable sample protection Malfunction alarms Excellent insulation performance 33.1/37.5(lbs) 360*305*445(mm) 14.2*12.0*17.5(in) 417*357*698(mm) 16.4*14.1*27.5(in) LN 2 Margin Insufficient Alarm N Low Battery Alarm Y Sensor Error Alarm Y Main Power Off Alarm Y Charge Indicator Y LN 2 Injection Test Button N Foot N Certificate CE 19 UL 20 Cryo Freezer & ULT Freezer Technical Data • • • • • • ULT Freezer Biomedical ULT Freezer Extended Pull-up Time During Power Failure Superior • Special V.I.P(Vacuum Insulation Panel) design with extra insulation factor cuts down heat loss to cabinet by 25% • High efficiency hrdrocarbon refrigerant based refrigeration system increases the efficiency by 45% than previous model • Four individual insulated inner door to keep the cold air inside • Pressure equalization port provides superior air flow making it possible to drastically reduce the stress on the freezer • Low noise 50dB(A) (reference data) • Pull-up time measures the time taken for temperature to rise up (from -80°C to -50°C ) at 25°C ambient when the power is interrupted • Haier has the best pull-up time among the ULT freezers compared with competitors’ largest volume product DW-86L728J Pull-up test at 25°C ambient 40 30 20 10 0 Alarms (visual and audible) Safety • Excellent temperature uniformity for an exacting sample storage requirement • High efficiency and reliability cooling fans ensure energy savings and long term storage safety Adjustable High/Low temperature alarm Sensor error Low battery Door ajar Power failure Hot condenser High ambient Remote alarm contact Temperature (°C) • • • • • • • • -10 -20 -30 -40 -60 -70 -80 -90 -100 0 Global Most Energy Efficiency 50 100 150 200 250 300 350 400 450 500 550 600 650 Time (Min) 307 (min) 220 (min) Haier Brand T DW-86L728J 184 (min) Brand N 150 (min) Brand P Electricity charge of a 700-liter ULT Freezer Ambient Temperature Electricity Charge (1year) Electricity Charge (5year) Electricity Charge (10year) DW-86L728J 10.5* 25°C € 1,724.6 € 8,623.1 € 17,246.3 Brand P 11.5 22~26°C € 1,888.9 € 9,444.4 € 18,888.8 €90,000.0 Brand N 15.2 23°C € 2,496.6 € 12,483.0 € 24,966.0 €80,000.0 Brand T 19.0 25°C € 3,120.8 € 15,603.8 € 31,207.5 €70,000.0 Notes:*Typical data - individual units may vary and power consumption will depend on loading and operating conditions. Freezer set-point -80°C, ambient temperature 25°C, unloaded, 220~240V 50Hz power supply €90,000.0 • Compared with Brand P, Haier DW-86L728J will help you to save €1,642.5 electricity charge in 10 years • Compared with Brand N, Haier DW-86L728J will help you to save €7,719.7 electricity charge 10 years • Compared with Brand T, Haier DW-86L728J will help you to save €13,961.2 electricity charge 10 years €60,000.0 • The new Eco-friendly Haier ULT freezer is the most energy-efficient one in the world which is designed to help you save energy. Average Power Consumption (Kwh/day) €50,000.0 €40,000.0 20 €30,000.0 15 UP TO €10,000.0 10 €0 5 (10.5) (19.0) (15.2) (11.5) Brand T Brand N Brand P 0 Haier 21 €20,000.0 45% 1 2 3 4 5 6 7 8 9 10 (Year) *The calculation of electricity reference to the German average industrial electricity 22 Brand T Brand P Brand N Haier DW-86L728J Cryo Freezer & ULT Freezer Haier DW-86L728J Electricity Charge for ten years compared with other bands with similar capacity Power Consumption (Kwh/Day) Model ULT Freezer Biomedical Haier to release the largest ultra-low temperature storage freezer with touch screen control in the global market. UNIQUE INVENTORY MANAGEMENT SYSTEM(IMS) ULT Freezer Two Modes Selection For customers who require the strictest tolerances, our high performance mode provides the tightest temperature uniformity. For most applications, our energy savings mode offers excellent temperature control, plus up to 13.5% savings on energy usage. • High-Performance Mode Designed with GMP applications in mind. Outstanding temperature uniformity and peak variation from setpoint • Energy-Savings Mode Excellent temperature uniformity up to 13.5% energy savings over high-performance mode 18.5 High performance 16 Energy savings Energy Efficient Layered display for sample storage, clear at a glance, easier to manage 16 Haier energy consumption is the lowest of all manufactures' largest capacity ULT Freezers Notes:Freezer set-point -80°C, ambient temperature 25°C, unloaded, 220~240V 50Hz power supply Haier DW-86L959 Brand T 21.8 24.6 Brand P Average Power Consumption (KWh/day) Extended Pull-up Time During A Power Failure • Pull-up time measures the time taken for temperatureto rise up (from -80°C to -50°C ) at 32°C ambient when the power is interrupted • Haier has the best Pull-up time among the ULT freezers compared with competitors’ largest volume product DW-86L959 Haier DW-86L959 Brand P 40 Brand T USB Interface Temperature(°C) 20 Access Security Swiping Card(Optional) Message and notepad function to transmit the information conveniently The enhanced security card control can prevent discretional opening , thus protect your sample records. 23 0 -20 -40 -60 -80 -100 0 200 400 600 800 1000 1200 260 Time(Min) 24 247 120 Cryo Freezer & ULT Freezer Pull-up test at 32°C ambient ULT Water Cooling Biomedical ULT Water Cooling Our water cooled ULT freezers are designed to meet strict requirements for storage of plasma, biological materials, vaccines, reagents, specimens, etc. And ideal for material storage in hospitals, clinics, blood banks and medical research facilities, etc. Model Advantages Energy Efficiency High efficient and energy saving, reducing energy consumption under the same storage capacity by more than 20%, and cost saving Environmental Friendly Water cooled system can take away 90% exhaust heat without air conditioning, this option utilizes the cascade refrigeration design to reuse energy produced by an ultra-low freezer while delivering additional energy-savings and high performance cooling. It provides a range of benefits Intelligent control, More durable, Improved sample security, Low noise Technical Data Performance Control Electrical Data DW-86L828W DW-86L959W Cabinet Type Upright Upright Climate Class N N Direct cooling Cooling Type Direct cooling Defrost Mode Manual Manual Refrigerant CFC-Free CFC-Free Noise(dB(A)) 49 49 Cooling Performance(°C) -86 -86 Temp Range(°C) -40~-86 -40~-86 Controller Microprocessor Microprocessor Display LED Touch Screen LCD Power Supply(V/HZ) 220~240/50 220~240/50 Power(W) 1200 1300 Electrical Current 9 9 Capacity(L/Cu.Ft) 828/29.2 959/33.9 Net/Gross Weight(approx) Interior Dimension(W*D*H) Dimensions Exterior Dimension(W*D*H) The water quantity in water cooled system, can be intelligent controlled by pressure valve automatically, to make the compressor in the best operating condition and extend the usable life of freezer. High quality hermetically sealed compressor with special design, noise level lower than 50dB(A), creating a comfortable working environment It is equipped with resettable pressure protection switch design, when the water cooled system failure, the protection switch can breaker trip automatically, for protecting the refrigeration system of freezer. 50dB Functions Refrigeration system High efficient and energy saving, reducing energy consumption under the same storage capacity by more than 20%, and cost saving The water cooled condenser option can take away 90% the heat generated in the process of refrigeration to the outdoor without air conditioning, making the laboratory environment more comfortable. Accessories Others 25 380/410 450/485 837.8/903.9 992.1/1069.2 (mm) 870*716*1310 1016*716*1310 (in) 34.3*28.2*51.6 40.4*28.2*51.6 (mm) 1145*980*1980 1296*998*1980 (in) 45.1*38.6*78.0 51.0*39.3*78.0 (mm) 1190*1045*2150 1365*1105*2150 (in) 46.9*41.1*84.6 53.7*43.5*84.6 Container load(20'/40'/40'H) 8/20/20 8/16/16 High/Low Temp Y Y Hot Condenser Y Y Power Failure Y Y High/Low Voltage N/A Y Sensor Error Y Y Low Battery Y Y High Ambient Temp Y Y Door Ajar Y Y Caster Y Y Foot Y Y Packing Dimension(W*D*H) Ergonomic Design (kg) (lbs) Test Hole Y/1 Y/2 Shelves/Inner doors 3/4 3/4 Y USB Interface Y Remote Alarm Y Y Temp Recorder Optional Optional Rs232/485 Interface Optional Optional CO2 Backup System Optional Optional LN2 Backup System Optional Optional Certificate CE CE 26 ULT Water Cooling Specification -86°C ULT Freezer Biomedical -86°C ULT Freezer Specification Technical Data DW-86L338J DW-86L388A DW-86L388J DW-86L486 DW-86L490J DW-86L578 DW-86L578J Upright Upright Upright Upright Upright Upright Upright Upright DW-86L628 Upright Climate Class N N N N N N N N N N Cooling Type Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Defrost Mode Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual HC HFC HC HFC HC HFC HFC 50 49 50 -86 -86 HFC Refrigerant Control Cooling Performance(°C) Temp Range(°C) Controller Display Others 50 50 -86 -86 -86 -86 -86 -86 -86 -86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 Microprocessor Microprocessor Microprocessor LED LED Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED LED LED LED LED LED LED 115/60 220~240/50 220~240/50 220~240/50 220~240/50 208~230/60 115/60 LED 220~240/50 208~230/60 208~230/60 115/60 220~240/50 220~240/50 208~230/60 115/60 220~240/50 208~230/60 115/60 900 1000 1200 900 1000 1000 1000 1000 1200 900 1000 1000 1000 900 1200 1200 1200 1200 1200 1200 7.5 8 18 7.5 8 8 9 5.5 18 8 8 9 18 9 7 9 18 9 9 18 338/11.9 388/13.7 388/13.7 338/11.9 486/17.1 490/17.3 578/20.4 578/20.4 628/22.2 728/25.7 (kg) 238/278 238/278 255/286 255/286 290/310 295/335 300/330 300/330 301/323 345/385 (lbs) 524.7/612.9 524.7/612.9 562.2/630.5 562.2/630.5 639.3/683.4 650.4/738.5 661.4/727.5 661.4/727.5 663.6/712.1 760.6/848.8 Interior Dimension (W*D*H) (mm) 465*630*1165 465*630*1165 465*630*1310 465*630*1310 590*630*1310 590*630*1310 620*716*1310 620*716*1310 760*630*1310 766*716*1310 (in) 18.3*24.8*45.9 18.3*24.8*45.9 18.3*24.8*51.6 18.3*24.8*51.6 23.3*24.8*51.6 23.3*24.8*51.6 24.4*28.2*51.6 24.4*28.2*51.6 29.9*24.8*51.6 27.0*28.2*51.6 Exterior Dimension (W*D*H) (mm) 812*893*1846 812*893*1846 812*893*1980 812*893*1980 945*900*1980 860*900*1980 895*980*1980 895*980*1960 1035*900*1980 1041*980*1980 (in) 32.0*35.2*72.7 32.0*35.2*72.7 32.0*35.2*78.0 32.0*35.2*78.0 37.2*35.4*78.0 33.9*35.4*78.0 35.4*38.6*78.0 35.4*38.6*78.0 40.7*35.4*78.0 36.7*38.6*78.0 Packing Dimension (W*D*H) (mm) 875*970*2010 875*970*2010 875*970*2135 875*970*2135 995*995*2150 925*985*2150 1055*950*2150 1055*950*2125 1080*965*2150 1090*1050*2150 (in) 34.5*38.2*79 34.5*38.2*79 34.5*38.2*84.1 34.5*38.2*84.1 39.2*39.2*84.6 36.4*38.5*84.6 41.5*37.4*84.6 41.5*37.4*83.7 42.5*38*84.6 43*41.3*84.6 12/24/24 12/24/24 12/24/24 12/24/24 12/24/24 12/24/24 12/24/24 12/24/24 12/24/24 12/20/20 High/Low Temp Y Y Y Y Y Y Y Y Y Y Hot Condenser Y Y Y Y Y Y Y Y Y Y Power Failure Y Y Y Y Y Y Y Y Y Y N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Sensor Error Y Y Y Y Y Y Y Y Y Y Low Battery Y Y Y Y Y Y Y Y Y Y High Ambient Temp Y Y Y Y Y Y Y Y Y Y Door Ajar Y Y Y Y Y Y Y Y Y Y Caster Y Y Y Y Y Y Y Y Y Y Foot Y Y Y Y Y Y Y Y Y Y Test Hole Y/1 Y/2 Y/1 Y/2 Y/1 Y/2 Y/2 Y/2 Y/1 Y/2 Shelves/Inner doors Container load(20'/40'/40'H) Accessories 49 50 Electrical Current Net/Gross Weight (approx) Functions 50 Power(W) Capacity(L/Cu.Ft) Dimensions 50 HFC Upright -40~-86 220~240/50 208~230/60 Power Supply(V/HZ) Electrical Data HC 50 Noise(dB(A)) Performance DW-86L728 DW-86L338 High/Low Voltage 3/2 3/2 3/2 3/2 3/4 3/4 3/4 3/4 3/4 3/4 USB Interface Y Y Y Y Y Y Y Y Y Y Remote Alarm Y Y Y Y Y Y Y Y Y Y N/A Y N/A Y Y Y Y Y Y Y Temp Recorder Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Rs232/485 Interface Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional CO2 Backup System Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional LN2 Backup System Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional CE,UL CE CE CE CE,UL UL CE CE,UL CE,UL 5Vpower supply module Certificate CE / Product appearance and specifications are subject to change without notice 27 28 Cryo Freezer & ULT Freezer Model Cabinet Type Technical Data Performance Control DW-86W420 DW-86W420J Chest Chest Chest Chest N N N N N N N Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Climate Class N N Cooling Type Direct cooling Defrost Mode DW-86W100 Manual Manual Manual Manual Manual Manual Manual Manual Manual Refrigerant HC HFC HFC HC HFC HFC HC HFC HC Noise(dB(A)) 50 49 49 50 49 49 49 50 49 Cooling Performance(°C) -86 -86 -86 -86 -86 -86 -86 -86 -86 Temp Range(°C) Controller Display Power(W) (kg) -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 -40~-86 Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED Touch Screen LCD LED LED Touch Screen LCD LED LED LED 220~240/50 220~240/50 208~230/60 220~240/50 208~230/60 220~240/50 220~240/50 220~240/50/60 115/60 220~240/50 220~240/50 220~240/50 208~230/60 1200 1000 1300 650 650 550 1000 1000 9 10 9 4 7.5 7.5 959/33.9 100/3.5 100/3.5 420/14.8 450/485 138/160 138/160 310/357 310/357 1000 1200 1200 1200 10 8 9 9 728/25.7 729/25.7 828/29.2 828/29.2 345/385 350/385 380/410 380/410 LED 7.5 12 1000 7.5 420/14.8 (lbs) 760.6/848.8 772.3/848.8 837.8/903.9 837.8/903.9 992.1/1069.2 304.2/352.7 304.2/352.7 683.4/787.1 683.4/787.1 Interior Dimension (W*D*H) (mm) 766*716*1310 766*716*1310 870*716*1310 870*716*1310 1016*716*1310 470*450*480 470*450*480 1367*462*652 1367*462*652 (in) 27.0*28.2*51.6 27.0*28.2*51.6 34.3*28.2*51.6 34.3*28.2*51.6 40.4*28.2*51.6 18.5*17.7*18.9 18.5*17.7*18.9 53.8*18.2*25.7 53.8*18.2*25.7 Exterior Dimension (W*D*H) (mm) 1041*980*1980 1046*998*1980 1145*980*1980 1145*980*1980 1296*998*1980 769*825*1120 769*825*1120 2130*870*1020 2130*870*1020 (in) 36.7*38.6*78.0 41.2*39.3*78.0 45.1*38.6*78.0 45.1*38.6*78.0 51.0*39.3*78.0 30.34*32.5*44.1 30.34*32.5*44.1 83.9*34.3*40.2 83.9*34.3*40.2 Packing Dimension (W*D*H) (mm) 1090*1050*2150 1100*1095*2150 1190*1045*2150 1190*1045*2150 1365*1105*2150 845*855*1250 845*855*1250 2195*895*1130 2195*895*1130 (in) 43*41.3*84.6 43.3*43.1*84.6 46.9*41.1*84.6 46.9*41.1*84.6 53.7*43.5*84.3 33.3*33.7*49.2 32.9*33.9*48.6 86.4*35.2*44.5 90.6*38.2*45.8 12/20/20 10/20/20 8/20/20 8/20/20 8/16/84.6 12/24/48 12/24/48 6/12/24 6/12/24 High/Low Temp Y Y Y Y Y Y Y Y Y Hot Condenser Y Y Y Y Y Y Y Y Y Power Failure Y Y Y Y Y Y Y Y Y N/A Y N/A N/A Y Y N/A Y N/A Sensor Error Y Y Y Y Y Y Y Y Y Low Battery Y Y Y Y Y Y Y Y Y High Ambient Temp Y Y Y Y Y Y Y Y Y Door Ajar Y Y Y Y Y N/A Y N/A Y Caster Y Y Y Y Y Y Y Y Y Container load(20'/40'/40'H) High/Low Voltage Y Y Y Y Y Y Y Y Y Test Hole Y/2 Y/2 Y/1 Y/2 Y/2 Y/1 Y/1 Y/1 Y/1 Shelves/Inner doors Foot Others DW-86W100J Upright Upright Net/Gross Weight (approx) Accessories DW-86L959 Upright Upright Capacity(L/Cu.Ft) Functions DW-86L828J Upright DW-86L728J Electrical Current Dimensions DW-86L828 DW-86L729 Model Cabinet Type Power Supply(V/HZ) Electrical Data -86°C ULT Freezer 3/4 3/4 3/4 3/4 3/4 -/1 -/1 -/3 -/3 USB Interface Y Y Y Y Y N/A Y N/A Y Remote Alarm Y Y Y Y Y Y Y Y Y 5Vpower supply module Y Y Y Y Y N/A N/A N/A N/A Temp Recorder Optional Optional Optional Optional Optional Optional Optional Optional Optional Rs232/485 Interface Optional Optional Optional Optional Optional Optional Optional Optional Optional CO2 Backup System Optional Optional Optional Optional Optional Optional Optional Optional Optional LN2 Backup System Optional Optional Optional Optional Optional Optional Optional Optional Optional CE CE,UL CE,UL CE CE CE,UL CE CE,UL CE、UL Certificate Product appearance and specifications are subject to change without notice 29 30 Cryo Freezer & ULT Freezer -86°C ULT Freezer Biomedical Consumables for ULT Freezer 31 32 PC Freezer Boxes PP Freezer Boxes Biomedical F FEATURES ■ ■ ■ ■ Made of Polycarbonate(PC) Sturdy and durable Temperature range: stable from -196ºC to 121ºC Suitable for liquid nitrogen storage Features ■ 3 4 5 6 7 8 9 10 A 41 42 43 44 45 46 47 48 49 50 A Boxes are designed with international standard size, which can f it all of the standard cryogenic vials and freezer racks 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 O O 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Store in mechanical freezers Boxes are vented, allowing rapid cooling of contents and full drainage B C D E B C F Made of polypropylene for use with temperature from -80ºC to 121ºC G HBB-281-PC B Chemically resistant to alcohols and mild organic solvents HBB-200-C Dimensions: 133 x 133 x 53.5mm F ■ 2 11 12 13 14 15 16 17 18 19 20 31 32 33 34 35 36 37 38 39 40 C ■ O 21 22 23 24 25 26 27 28 29 30 E ■ 1 O C ■ For easy inventory management of cryogenic vials used in tissue culture, pharmaceutical research and other biotechnology labs D ■ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 2 3 4 5 6 7 8 9 10 Ordering Information 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Box Design 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 81 82 83 84 85 86 87 88 89 90 73 74 75 76 77 78 79 80 81 91 92 93 94 95 96 97 98 99 100 A A G Cat# Well Material Color Height PC Assorted Colors(Red, Greenmixed) 2inch Dimensions Unit ■ 51 52 53 54 55 56 57 58 59 60 B T130 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 HBB-281-PC 81-well HBB-200-PP 133*133*53.5(mm) 50 sets/case 5.2*5.2*2.2(in) ■ ■ Dimensions: T130 : 133 x 133 x 53.5mm HBB-200-PP : 133 x 133 x 53.5mm HBB-200-C 100-well PC Box Design Assorted Colors(Red, Yellow, Blue, Green mixed) 2inch 133*133*53.5(mm) 5.2*5.2*2.2(in) 4 colors/bag, 4 bags/box, 24sets/case ■ ■ ■ ■ 9x9 well storage (81-well total) or 10x10 well storage (100-well total) ■ Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials ■ HBB-200-PP box with numeric identification on each column for quick 9x9 well storage (81-well total) or 10x10 well storage (100-well total) Boxes are designed with international standard size, which can fit all of the standard cryogenic vials and freezer racks With 4 assorted colors: red, yellow, green, and blue for better color-coding Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials 81-well box features a removable lid includes a numbered grid for orientation 100-well box with numeric identification on each column for quick sample identification sample identification Ordering Information Cat# Well Material Sterile Unit T130 81-well PP No 50sets/ case HBB-200-PP 100-well PP No 50sets/ case 33 Easy for sample organization Each box includes drain holes and air vents in the lid and bottom to minimize condensation 34 Cryogenic Supplies Numbered grid for orientation Consumables For ULT Freezer ULT Model DW-86L338 /338J FEATURES ■ ■ ■ ■ ■ ■ ■ Sliding drawer and side access type design for choose. Fully functional Freezer Rack is constructed of corrosion-resistant stainless steel Sliding Drawer Freezer Racks include handles for easy removal off the shelf Optimize Freezer Storage Space Ideal for storage of 2” standard size boxes Fits most standard upright freezers Available with Sliding Drawer, Frame Type and Vertical Type Freezer Racks Racks Model DCJ-54-A(2014) DCJ-54-B(2014) (the 2nd and the 3rd layer) DCJ-44-A(2014) DCJ-44-B(2014) (the 1st and the 4th layer) DW-86L388A DCJ-54-A(2014) /388J DCJ-54-B(2014) DCJ-54-A(2014) DW-86L486 DCJ-54-B(2014) DCJ-54-A(2014) DCJ-54-B(2014) (the 1st and the 2nd layer) DW-86L490 /490J DCJ-44-A(2014) DCJ-44-B(2014) (the 3rd and the 4th layer) DW-86L578 DCJ-55-A(2014) DCJ-55-B(2014) /578J DW-86L628 DCJ-54-A(2014) DCJ-54-B(2014) DW-86L728 DCJ-55-A(2014) /728J DCJ-55-B(2014) DW-86L729 DCJ-55-A(2014) DCJ-55-B(2014) Parameters Product DW-86L828 DCJ-55-A(2014) DCJ-55-B(2014) /828J Model DCJ-44-A(2014) DCJ-44-B(2014) DCJ-54-A(2014) 2 inch stainless stell rack DCJ-54-B(2014) DCJ-55-A(2014) DCJ-55-B(2014) DCJ-08-A(2014) DCJ-10-A(2014) Rack Description Rack Dimension(W*D*H) 2 inch stainless steel rack 4*4 (2 inch box *16) 2 inch stainless steel drawer rack 4*4 (2 inch box *16) 2 inch stainless steel rack 5*4 (2 inch box *20) 2 inch stainless steel drawer rack 5*4 (2 inch box *20) 2 inch stainless steel rack 5*5 (2 inch box *25) 2 inch stainless steel drawer rack 5*5 (2 inch box *25) 2 inch stainless steel rack 8*1 (2 inch box *8) 2 inch stainless steel rack 10*1 (2 inch box *10) "138*565*24(mm) 5.4*21.4*9.2(in)" "140*565*24(mm) 5.5*21.8*9.3(in)" "138*565*293(mm) 5.4*21.4*11.3(in)" "140*565*293(mm) 5.5*21.8*11.4(in)" "138*685*293(mm) 5.4*26.8*11.3(in)" "140*685*293(mm) 5.5*27.1*11.4(in)" "140*140*480(mm) 5.4*5.6*18.1(in)" "140*140*600(mm) 5.4*5.6*24.9(in)" 35 Boxes Q'ty/layer 3 3 3 4 4 4 4 5 5 5 6 ULT Freezer Models DW-86L338/338J/490/490J DW-86L338/388A/486/490/628 DW-86L578/728/828/578J/ 728J/828J/729/959 DCJ-55-A(2014) DW-86L959 DCJ-55-B(2014) DW-86W100 DCJ-08-A(2014) DW-86W420 DCJ-10-A(2014) 7 9 27 DW-86W100 DW-150W200 DCJ-10-A(2014) DW-86W420/DW-150W200 12 Vials Total Q'ty For ULT Freezer Material Model Q'ty/ Rack Model Q'ty/Box Q'ty/Rack PP T130 20 1.0/1.5/2.0ml 81 1620 Racks Boxes Vials 120 9720 120 12000 PP HBB-200-PP 20 1.0/1.5/2.0ml 100 2000 PC HBB-281-PC 20 1.0/1.5/2.0ml 81 1620 PC HBB-200-C 20 1.0/1.5/2.0ml 100 PP T130 16 1.0/1.5/2.0ml PP HBB-200-PP 16 1.0/1.5/2.0ml PC HBB-281-PC 16 1.0/1.5/2.0ml 81 1296 PC HBB-200-C 16 1.0/1.5/2.0ml 100 1600 96 9600 PP T130 20 1.0/1.5/2.0ml 81 1620 240 19440 240 24000 240 19440 6 120 9720 2000 120 12000 81 1296 96 7776 100 1600 96 9600 96 7776 6 PP HBB-200-PP 20 1.0/1.5/2.0ml 100 2000 PC HBB-281-PC 20 1.0/1.5/2.0ml 81 1620 PC HBB-200-C 20 1.0/1.5/2.0ml 100 2000 240 24000 PP T130 20 1.0/1.5/2.0ml 81 1620 320 25920 PP HBB-200-PP 20 1.0/1.5/2.0ml 100 2000 320 32000 PC HBB-281-PC 20 1.0/1.5/2.0ml 81 1620 320 25920 PC HBB-200-C 20 1.0/1.5/2.0ml 100 2000 320 32000 PP T130 20 1.0/1.5/2.0ml 81 1620 160 12960 PP HBB-200-PP 20 1.0/1.5/2.0ml 100 2000 160 16000 PC HBB-281-PC 20 1.0/1.5/2.0ml 81 1620 160 12960 PC HBB-200-C 20 1.0/1.5/2.0ml 100 2000 160 16000 PP T130 16 1.0/1.5/2.0ml 81 1296 128 10368 PP HBB-200-PP 16 1.0/1.5/2.0ml 100 1600 128 12800 PC HBB-281-PC 16 1.0/1.5/2.0ml 81 1296 128 10368 PC HBB-200-C 16 100 1600 128 12800 PP T130 25 1.0/1.5/2.0ml 1.0/1.5/2.0ml 81 2025 400 32400 PP HBB-200-PP 25 1.0/1.5/2.0ml 100 2500 400 40000 PC HBB-281-PC 25 1.0/1.5/2.0ml 81 2025 400 32400 PC HBB-200-C 25 1.0/1.5/2.0ml 100 2500 400 40000 PP T130 20 1.0/1.5/2.0ml 81 1620 400 32400 PP HBB-200-PP 20 1.0/1.5/2.0ml 100 2000 400 40000 PC HBB-281-PC 20 1.0/1.5/2.0ml 81 1620 400 32400 PC HBB-200-C 20 1.0/1.5/2.0ml 100 2000 400 40000 PP T130 25 1.0/1.5/2.0ml 81 2025 500 40500 PP HBB-200-PP 25 1.0/1.5/2.0ml 100 2500 500 50000 PC HBB-281-PC 25 1.0/1.5/2.0ml 81 2025 500 40500 PC HBB-200-C 25 1.0/1.5/2.0ml 100 2500 500 50000 PP T130 25 1.0/1.5/2.0ml 81 2025 500 40500 PP HBB-200-PP 25 1.0/1.5/2.0ml 100 2500 500 50000 PC HBB-281-PC 25 1.0/1.5/2.0ml 81 2025 500 40500 PC HBB-200-C 25 1.0/1.5/2.0ml 100 2500 500 50000 PP T130 25 1.0/1.5/2.0ml 81 2025 600 48600 PP HBB-200-PP 25 1.0/1.5/2.0ml 100 2500 600 60000 PC HBB-281-PC 25 1.0/1.5/2.0ml 81 2025 600 48600 PC HBB-200-C 25 1.0/1.5/2.0ml 100 2500 600 60000 PP T130 25 1.0/1.5/2.0ml 81 2025 700 56700 PP HBB-200-PP 25 1.0/1.5/2.0ml 100 2500 700 70000 PC HBB-281-PC 25 1.0/1.5/2.0ml 81 2025 700 56700 PC HBB-200-C 25 1.0/1.5/2.0ml 100 2500 700 70000 PP T130 8 1.0/1.5/2.0ml 81 648 72 5832 PP HBB-200-PP 8 1.0/1.5/2.0ml 100 800 72 7200 PC HBB-281-PC 8 1.0/1.5/2.0ml 81 648 72 5832 PC HBB-200-C 8 1.0/1.5/2.0ml 100 800 72 7200 PP T130 10 1.0/1.5/2.0ml 81 810 270 21870 270 27000 270 21870 27000 12 16 8 8 16 20 20 20 24 28 9 PP HBB-200-PP 10 1.0/1.5/2.0ml 100 1000 PC HBB-281-PC 10 1.0/1.5/2.0ml 81 810 PC HBB-200-C 10 1.0/1.5/2.0ml 100 1000 270 PP T130 10 1.0/1.5/2.0ml 81 810 120 9720 PP HBB-200-PP 10 1.0/1.5/2.0ml 100 1000 120 12000 PC HBB-281-PC 10 1.0/1.5/2.0ml 81 810 PC HBB-200-C 10 1.0/1.5/2.0ml 100 1000 36 27 12 120 9720 120 12000 Cryogenic Supplies Stainless Steel Freezer Racks Biomedical Biomedical Freezer 37 38 -40°C Biomedical Freezer (Upright) Biomedical -40°C Biomedical Freezer (Upright) Safety This product is design for storage of critical and temperature sensitive biological samples, medical products, and so on in institutions such as blood banks, hospitals, etc. Alarm system, including high temperature, sensor error, power failure, door ajar, low battery, high ambient temperature, etc The audio-visual alarms, and remote alarm contacts Key Features Backup battery for continuously monitoring and displaying the interior temperature over 48hs after power failure Forced air and frost-free design: Storage at -40°C with automatic defrost, Non-invasive defrost with time and temperature guided cycle, ensure temperature stability and minimize energy use The USB port are standard, the temp data can be recorded on chart paper or loaded in flash disc, maximum data safety Intelligent operation and control at -40°C and forced air circulation for uniform temperature and high-performance refrigeration Lockable door with Padlock for added sample security Microprocessor controls with digital display with 0.1°C increment, and adjustable temperature range: -20~-40°C Ergonomic Design Self closing door with 90°stay-open feature, energy-conserving, maintains temperature uniformity to protect your valuable samples Interior brushed stainless steel liner and Exterior coated steel plate, corrosion free 5 adjustable stainless steel shelves and drawers with partition to separately store varied plasma bags Backup battery protection USB Malfunction Alarms Casters and leveling leg, easy to move and lock DW-40L420F Pull down test at 25°C ambient Temperature Uniformity -35 -36 Temperature (°C) Temperature (°C) 30 25 20 10 0 -10 -20 -30 -40 -50 Drawer Microprocessor control panel Air distribution -38 -39 -40 -41 -42 -43 -44 -45 10 35 60 85 110 135 160 185 210 235 260 285 310 335 360 0 Time (min) 25 50 75 100 125 150 175 200 225 250 275 Time (min) *Freezer set-point -40 °C,ambient temperature 25 °C Product appearance and specifications are subject to change without notice 39 -37 40 Biomedical Freezer Padlock -40°C Biomedical Freezer(Double Doors Type) Biomedical The -40°C deep freezer offers a large capacity storage space with fast temperature performance. Integrated design of cold shelf and evaporator provides additional refrigeration efficiency. This product is designed to store vaccines, blood plasma, and many other biological materials. Installations can be found in research institutions and clinical sites in life science, electronic testing and medical markets. -40°C Biomedical Freezer(Double Doors Type) Haier ‘s next generation low temperature storage freezer, DW-40L348, is designed based on the original work horse platform of DW-40L508. The new freezer model operates with two capillary tubes and is equipped with dual gaskets to improve the temperature uniformity through the chamber drastically. It can be installed to satisfy tougher application requirements in universities, research institutions and blood banks. Reliability and Key Features • Rated for -40°C at 32 °C ambient • Rapid cooling with shelf evaporator • Improved temperature uniformity with dual capillary tube design at the range of -20 °C to -40°C • Improved door seal design with two gaskets maintains cabinet temperature more efficiently • Frost buildup is reduced • Insulation thickness is 90 mm for additional robustness, less power consumption and more temperature retaining ability • Drawer design maximizes storage space. One unit can hold 360 bags of 230 ml blood bags Safety • Multiple malfunction alarms include high/low temperature, power failure, sensor error, low battery, high/low ambient temperature • Two types of alarms: buzzer and flashing light DW-40L508 DW-40L348 Ergonomic Design Control panel Drawer Shelf 41 Biomedical Freezer • LED digital display for clear observation • Double door design with independent locks reduces air leakage to ensure temperature stability and lower power consumption • Tracks to label drawers for product identification Handle 42 -40°C Biomedical Freezer (Upright) Biomedical -40°C Biomedical Freezer (Chest) Key Features Reliability and Key Features Microprocessor control, adjustable temperature range :-20°C to -40°C LED digital display and increment at 0.1°C Permanently lubricated cooling fan for safety and longevity Rapid cooling with shelf evaporator Removable double outer door seal design, good sealing effect and energy saving • High efficiency low temperature compressor with known field reliability • Chemically stable, CFC-free, commercially available and environmentally safe refrigerant • Permanently lubricated cooling fan for safety and longevity , high density insulation foam for stable and long term storage temperature • Optimized refrigeration system designed to maximize cooling effect and temperature uniformity • Microprocessor control, digital display, adjustable temperature range: -20°C~-40°C • LED digital display for clear observation • Wide voltage tolerance design with applicable voltage range of 198~252 V/AC Ergonomic Design USB data logging and temperature recorder (optional) Padlock with stainless steel cylinder for safe storage Drawers are designed with label holders for item identification Safety • Multiple malfunction alarms to detect high / low temperature, sensor error and power failure • Two types of alarm indications: audible buzzing and visual flashing light Safety Multiple malfunction alarms include high/low temperature, sensor error, power failure, high ambient temperature, low battery Alarm Types: buzzer, flashing light, remote alarm Ergonomic Design Electronic Thermostat Inner Temperature (°C) DW-40W380 Pull-up test at 32°C ambient Temperature (°C) DW-40W380 Pull down test at 32°C ambient seal USB data logging(optional) 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 0 Time (H) 43 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Time (H) 44 5 5.5 6 6.5 7 7.5 Biomedical Freezer DW-40L278 • Door lock for storage safety • Standard ø40 access port for testing instrumentation except model DW-40W380 • Corrosion proof cabinet interior design • Suitable for a variety of storage baskets Model Technical Data Performan ce Control Electrical Data 835*895*2020(mm) 32.9*35.2*79.5(in) DW-40L420F Upright SN,N Forced air cooling / CFC-Free 45dB -40 -20~-40 Microprocessor LED 220~240/50HZ 900 4.5A 420L 195/225(kg) 429.9/496.0(lbs) 685*610*1028mm 27.0*24.0*40.5(in) 950*890*1900mm 37.4*74.4*74.8(in) 980*905*2040mm 38.6*36.0*80.3(in) 24/48/48 14/28/28 12/24/24 12/24/24 Y Y Y Y Y Y Power Failu re High/Low Voltage N/A N/A N/A Y Y N/A Y Y N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Sensor Error w Battery High Ambient Temp Y Y N/A N/A N/A N/A Y Y Y Y Y Y Y Y Y N/A 3/N/A N/A Y 7/N/A N/A Y 12/Optional Optional Y Y Y Y Y Y Y Y Y Y Y Y Optional CE Y N/A N/A N/A Cabinet Type Climate Class ooling Type efrost Mode efrigerant Noise(dB(A)) ooling Per formance(°C) emperature Range(°C) ontroller Display ower Supply(V/Hz) ower(W) Electrical Current(A) Capaci ty(L/Cu.Ft) Net/Gross Weight (approx) Dimensions Interior Dimension (W*D*H) Exterior Dimension (W*D*H) Packing Dimension (W*D*H) Container Load (20'/40'/40'H) High/Low Temperature Remote Alarm Functions -40°C Biomedical Freezer Accessories Caster ot est Hole Drawers/Inner Doors USB Interface Temperature Recorder Others Certificate DW-40L92 Upright N Direct cooling Manual CFC-Free DW-40L262 Upright N Direct cooling Manual CFC-Free Upright, double door N Direct cooling Manual CFC-Free 40 -40 -20~-40 Microprocessor LED 44 -40 -20~-40 Microprocessor LED 45 -40 -20~-40 Microprocessor LED 220~240/50 200 0.5 92/3.3 220~240/50 115/60 340 600 3.9 7.5 262/9.3 220~240/50 360 2.9 348/12.3 46/51(kg) 88/88(kg) 137/145(kg) 101.4/112.4(lbs) 465*440*645(mm) 194.0/194.0(lbs) 480*465*1430(mm) 302.0/319.7(lbs) 535*610*1228(mm) 18.3*17.3*25.4(in) 597*610*860(mm) 18.9*18.3*56.3(in) 657*685*1665(mm) 745*675* 21.1*24.0*48.3(in) 765*810*1860(mm) 23.5*24.0*33.9(in) 660*700*935(mm) 26*27.6*36.8(in) 25.9*27.0*65.6(in) DW-40L348 3.1 29.3*26.6* 775*760*1755(mm) 805*725*1970(mm) 30.5*30*69(in) 31.7*28.5*77.6(in) 54/108/108 CE CE / 30.1*32.0*73.2(in) CE DW-40L508 Upright, double door N Direct cooling Manual CFC-Free 45 -40 -20~-40 Microprocessor LED 220~240/50 430 2.9 208~230/60 430 2.9 DW-40W100 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 255 5.0 115/60 255 5.0 DW-40W255 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 410 4.2 DW-40W380 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 550 5.1 208~230/60 550 5.1 490/17.3 164/200(kg) 100/3.5 43/46(kg) 255/9.0 70/82(kg) 380/13.4 82/89(kg) 360.8/440.9(lbs) 685*610*1228(mm) 94.8/101.4(lbs) 500*385*625(mm) 154/180.8(lbs) 1040*430*605(mm) 180.8/196.2(lbs) 1376*457*625(mm) 27.0*24*48.3(in) 915*810*1860(mm) 36.0*71.3*73.2(in) 19.7*15.2*24.6(in) 680*600*805(mm) 26.8*23.6*31.7(in) 40.9*16.9*23.8(in) 1243*633*838(mm) 48.9*24.9*33.0(in) 54.2*18.0*24.6(in) 1550*633*838(mm) 61.0*24.9*33.0(in) 980*905*2040(mm) 38.6*35.6*80.3(in) 740*650*880(mm) 29.1*25.6*34.6(in) 1320*755*905(mm) 59.8*29.7*35.6(in) 1635*760*900(mm) 64.4*29.9*35.4(in) 54/108/162 24/54/81 18/42/63 Y Y Y Y Y N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Y 10/Optional Optional Y / N/A Y / N/A N/A / N/A N/A N/A N/A CE CE CE CE Y Y Y N/A N/A Product appearance and specifications are subject to change without notice 45 46 Biomedical Freezer -40°C Biomedical Freezer Biomedical -25°C Biomedical Freezer -25°C Biomedical Freezer Model Technical Data Performance Control DW-25L262 Electrical Data Dimensions Functions Others 47 DW-25L92 DW-25L262 Cabinet Type Upright Upright Climate Class N N Cooling Type Direct Cooling Direct Cooling Defrost Mode Manual Manual Refrigerant CFC-Free CFC-Free Noise(dB(A)) 40 44 Cooling Performance(°C) -25 -25 Temp Range(°C) -10~-25 -10~-25 Controller Microprocessor Microprocessor Display LED LED Power Supply(V/HZ) 220/50 220/50 Power (W) 77 90 Electrical Current(A) 0.35 0.7 Capacity(L/Cu.Ft) 92/3.2 262/9.3 Net/Gross Weight(appox) 46/51(kg) 88/88(kg) Interior Dimensions(W×D×H)(mm) 435*410*635 480*465*1430 Exterior Dimensions(W×D×H)(mm) 597*610*860 657*685*1665 Packing Dimensions(W×D×H)(mm) 660*700*935 775*760*1755 Drawer Quantity(pcs) 3 7 Container Load(20'/40'/40'H) 50/108/108 24/48/48 High/Low Temp Y Y Sensor Error Y Y Certificate CE CE 48 Biomedical Freezer Biomedical Biomedical Combined Refrigerator and Freezer Combined Refrigerator and Freezer Refrigerator & Freezer Combination, Separate Controlled Excellent Performance Approved by Uzbekistan MOH 520 units combined refrigerator and freezers(model: HYCD-282A) was approved by Uzbekistan MOH. • Adjustable refrigerator compartment temperature range: 2°C to 8°C • Adjustable freezer compartment range: -20°C to -40°C Key Function • • • • • • • • USB port for data download Capable of recording temperature data for up to one month automatically Independent display for refrigerator section and freezer section Optional remote alarm and monitor via internet Drawers with divided compartments Shelves with divided sections Multiple alarms to detect malfunctions Multi-malfunction alarms, precautionary alarm Model Cabinet Type Climate Class Technical Data Performance Control Electrical Data Cooling Type Defrost Mode Refrigerant Noise(dB(A)) Cooling performance(°C) Temperature Range (°C) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) Net/Gross Weight(approx) Dimensions Interior Dimensions(W*D*H) Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H) HYCD-282 HYCD-282A Functions Accessories Others 49 Container load (20'/40'/40'H) High/Low Temperature Remote Alarm Power Failure Sensor Error Low Battery High Ambient Temp Caster Foot Test Hole Shelves/Drawers USB Interface Certificate HYCD-282 HYCD-282A Upright 4 Refrigertor:Forced air cooling Freezer: Direct cooling Refrigerator: Auto Freezer: Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 400 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator: 605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 775*720*1930(mm) 30.5*28.3*76(in) 21/45/45 Y Y Y Y Y Y Y Y Y Refrigerator:3/1 Freezer:0/2 Y CE Upright 4 Refrigertor:Forced air cooling Freezer: Direct cooling Refrigerator:Auto Freezer: Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 208-230/60 400 400 2.8 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator:605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 775*720*1930(mm) 30.5*28.3*76(in) 21/45/45 Y Y Y Y Y Y Y Y Y Refrigerator:3/1 Freezer:0/2 Y CE / 50 Combined Refrigerator and Freezer Specification Pharmacy Refrigerator 51 52 Biomedical Pharmacy Refrigerator Pharmacy Refrigerator Medical Refrigerator for Pakistan Aids The Haier pharmacy refrigerators are suitable for installation in drug stores, pharmaceutical companies, hospitals, epidemic prevention centers, and clinics. • 1000 units pharmacy refrigerator (model: HYC-360) was successfully provided for the tender of China Ministry of Commerce for supporting Pakistan Poliomyelitis Prevention Project in 2013. • 750 units pharmacy refrigerators was successfully approved by Philippines MOHFW in 2014. Reliability and Key Features Microprocessor control panel and digital display Permanently lubricated condenser fan motor Locks • High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ± 3°C • Adjustable temperature range 2~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 0.1°C • Large digital display screen • Wide voltage tolerance suitable for unstable voltage supply • Designed for ambient temperature 10~32°C with humidity below 85% Safety • Equipped with a complete temperature alarm system featuring audible buzzer and visible flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar, remote alarm, power failure and low battery Hermetically sealed compressor Access port Door handles Ergonomic Design • Optimized space utilization design with multi-level and adjustable shelf height to accommodate storage requirement of pharmaceutical products of various kinds • Safety lock to prevent unauthorized access • Caster design and leveling legs • Interior light Dual-pane glass door design, convenient and aesthetic HYC-1378 53 54 Pharmacy Refrigerator Leveling leg and caster Biomedical Pharmacy Refrigerator Pharmacy Refrigerator Technical Advantages • Accurate temperature control technology to make the temperature maintain 2~8 °C and increment at 0.1°C • Improved user interface with additional features include data USB port which can storage ten years data • Oversized air–cooled condenser improves the robustness of the refrigeration system reliability and refrigeration efficiency The updated Haier Pharmacy refrigerator, more professional, more intelligent and more stable. Optional Printer Display Panel Lock Optional USB Port Ergonomic Design • The new improved data storage management system is completed with a USB data port for downloading temperature data. Traceability of temperature performance is easily maintained • Heated double-pane glass door allows a clear display of stored products without condensation at 32°C and 85% relative humidity condition • LED interior light saves energy and provides bright lighting for viewing • Shelves with label holders meet demands of product archiving and retrieving Safety Evaporator Fan Access port • Microprocessor control, digital display, temperature uniformity within 3°C • Malfunction alarms include high/low temperature, door ajar, sensor error, power failure, low battery, remote alarm interface HYC-390 Pull-up test at 25°C ambient HYC-390 Pull down test at 25°C ambient Padlock Adjustable Shelf 30 60 90 120 0 Time (min) Electric Heating Glass Door 15 30 45 60 Time (min) Leveling leg and caster Caster HYC-390 55 56 Pharmacy Refrigerator Sealing Strip Biomedical Under-Counter Pharmacy Refrigerator Under-Counter Pharmacy Refrigerator Precision Constant Temperature, Exquisite Installation The first Under-counter pharmacy refrigerator in China, ultra low noise design, safety lock, perfect alarm system, safety protection. HYC-118 HYC-118A Reliability and Key Features • High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ±3°C • Adjustable temperature range 2~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 1 °C • Designed for ambient temperature 10~32°C with humidity below 60% Ergonomic Design • Interior LED light • Safety lock to prevent unauthorized access 57 58 Pharmacy Refrigerator Safety • Equipped with a complete temperature alarm system featuring audible buzzer and visual flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar, power failure, remote alarm interface Pharmacy Refrigerator Biomedical Pharmacy Refrigerator Specification Cabinet Type Technical Data HYC-68 HYC-290 HYC-390 Upright, single door Upright, single door Upright, single door Single glass door HYC-940 HYC-940F HYC-1378 Double glass door Double solid door Upright, double door N N N Forced air cooling Forced air cooling Forced air cooling HYC-610 HYC-390F Single solid door Upright, single door N N N N N N Cooling Type Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Defrost Mode Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free 35 35 32 32 43 43 43 43 43 45 45 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED LED LED LED Fluorescent Light Fluorescent Light LED LED LED LED LED LED LED Tmt. Range( °C) Controller Power Supply(V/Hz) Power(W) Capacity(L/Cu.Ft) 220~240/50 115/60 220~240/50 115/60 220~240/50 43 43 47 220~240/50 115/60 220~240/50 208~230/60 220~240/50 208~230/60 115/60 220~240/50 208~230/60 N N Forced air cooling Forced air cooling 115/60 220~240/50 208~230/60 115/60 220~240/50 208~230/60 220~240/50 208~230/60 115/60 220~240/50 208~230/60 115/60 45 45 220~240/50 220~240/50208~230/60 115/60 68 84 68 135 75 165 140 300 300 315 315 340 340 340 460 380 500 300 550 550 560 850 770 850 600 800 800 950 0.65 1.1 0.65 1.1 1.03 1.11 1.16 1.46 2.1 2.1 2.2 2.2 4.5 2.2 2.2 5.0 2.4 5.5 2.4 3.5 3.5 7.5 4.5 4.5 11 3 4.2 4.2 11 68/2.4 68/2.4 118/4.2 118/4.2 260/9.2 360/12.7 38/40(kg) 83.8/88.2(lbs) 390/13.8 290/10.2 610/21.6 890/31.4 890/31.4 1378/48.7 227/279(kg) 500.4/615.1(lbs) 1030*590*1425 40.6*23.2*56.1 1130*755*1980 44.5*29.7*78.0 207/259(kg) 456.4/571.1(lbs) 1030*590*1425 40.6*23.2*56.1 1130*755*1980 44.5*29.7*78.0 310/360(kg) 683.4/793.7(lbs) 1320*700*1500 52.0*27.6*59.1 1440*910*1980 56.7*35.8*78.0 1250*850*2130 49.2*33.5*83.9 1250*850*2130 1570*1010*2120(mm) 49.2*33.5*83.9 61.8*39.8*83.5(in) 530*555*1080 20.9*21.9*42.5 665*710*1665 26.2*28.0*65.6 530*555*1380 20.9*21.9*54.3 665*710*1965 26.2*28.0*77.4 204/227(kg) 449.7/500.4(lbs) 680*640*1400 26.8*25.2*55.1 780*840*1945 30.7*33.1*76.6 735*800*1800 28.9*31.5*70.9 735*800*2100 28.9*31.5*82.7 865*945*2090(mm) 34.1*37.2*82.3(in) 21/42/42 21/42/42 105/127(kg) 231.6/280.1(lbs) 116/139(kg) 255.8/306.6(lbs) 106/129(kg) 233.8/284.5(lbs) 12/26/26 8/18/18 8/18/18 6/12/12 High/Low Temperature Y Y Y Y Y Y Y Y Y Y Y Y Remote Alarm Y Y Y Y N/A N/A Y Y Y Y Y Y Y Power Failure Y Y Y Y Y Y Y Y Y Y Y Sensor Error Y Y Y Y Y Y Y Y Y Y Y Y Low Battery Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N/A N/A Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N/A N/A Y Y N/A N/A Y Y Y Y Y Y 2/1 2/1 3/1 3/1 4/- 5/- 5/- 7/- 6/- 12/- 12/- 12/- USB Interface N/A N/A N/A N/A N/A N/A Y Optional N/A N/A Y Tmt. Recorder N/A N/A N/A N/A N/A N/A N/A N/A Optional N/A N/A N/A CE,UL CE,UL CE,UL CE,UL CE CE CE CE CE CE CE CE Door Ajar Caster Foot Test Hole Accessories Shelves/Basket Certificate 48 84 41/46(kg) 38/40(kg) 46/51(kg) 88/100(kg) 99/114(kg) 83.8/88.2(lbs) 90.5/101.5(lbs) 101.5/112.5(lbs) 218.3/251.3(lbs) 194.0/220.5(lbs) Interior Dimensions (m- 415*385*505 415*385*505 515*415*630 515*415*630(mm) 550*460*1065(mm) 550*460*1340 m)(in) 16.3*15.2*19.9 16.3*15.2*19.9 20.3*16.3*24.8 20.3*16.3*24.8(in) 21.7*18.1*41.9(in) (W*D*H) 21.7*18.1*52.8 Exterior Dimensions (m- 495*580*660 495*580*660 597*635*835(mm) 597*635*835(mm) 620*655*1720(mm) 620*655*1955(mm) m)(in) 19.5*22.8*26.0 19.5*22.8*26.0 23.5*25*32.9(in) 23.5*25*32.9(in) 24.4*25.8*67.7(in) (W*D*H) 24.4*25.8*77.0 PackingDimensions (m- 540*640*710(mm) 540*640*710(mm) 680*690*910(mm) 680*690*910(mm) 695*720*1795(mm) 695*720*2080(mm) m)(in) 21.3*25.2*28.0(in) 21.3*25.2*28.0(in) 26.8*27.2*35.8(in) 26.8*27.2*35.8(in) 27.6*28.1*71.3(in) (W*D*H) 27.6*28.1*81.9 Container load 24/48/48 108/228/228 24/48/48 108/228/228 48/102/102 48/102/102 (20'/40'/40'H) Net/Gross Weight(approx) Others HYC-360 N Electrical Current(A) Functions HYC-260 N Display Dimensions HYC-118A Upright, solid door Upright, glass door Upright, solid door Upright, glass door Performance Noise(dB(A)) Electrical Data HYC-118 Climate Class Refrigerant Control HYC-68A Optional Y Product appearance and specifications are subject to change without notice 59 60 Pharmacy Refrigerator Model Blood Bank Refrigerator 61 62 Biomedical Blood Bank Refrigerator Blood Bank Refrigerator The Haier BBR series provides two styles to storage systems: basket-type and drawer type.They are built in compliance with the requirements of : Haier blood bank refrigerator are specially designed to store whole blood and blood derivatives. These refrigerators can also be used to store pharmacy and biological materials in hospitals and laboratories. • • • • AABB (American Association of Blood Banks) DIN 58371 (Germany, “Blutkonserven-Kühlgeräte”/Blood Refrigerators) BIS 4376-1: 1991 (UK, “Electrically operated blood storage refrigerators Specifications for closed reach-in types”) • In 2011, Haier won MOH tender blood bank refrigerator and -86°C ULT freezer in Russia market. • In 2011, Haier won the tender "Third National HIV/AIDS Control Project (NACP III)” and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers. LED light Dual-pane glass, electrical heating, free from condensation. Permanently lubricated evaporator fan motor Access port Reliability • Microprocessor controlled forced-air cooling with electrical heat compensation system • Digital temperature display for upper and lower sections in chamber with 0.1 °C resolution Key Features • Consistent cabinet temperature 2-6°C • High-tech integrated sensors to display and control temperature • Standard temperature recorder (Optional for HXC-158) • Auto-defrost to remove moisture on cooling surface • Large digital display for ease of observation Safety Temperature recorder Hermetically sealed compressor Ergonomic Design Leveling legl and caster HXC-358B 63 • Safety lock to prevent unauthorized access • Storage space designed for easy sorting of a variety of blood products • Caster design and interior light • Optional baskets or stainless steel drawers 64 Blood Bank Refrigerator Blood basket or drawer is optional • Dual displays of operational parameter temperature recorder display) • Built-in backup battery to display temperature and to operate audible and visual alarm systems for up to 48 hours without ac power • Three types of alarm alerts: Buzzer, Flashing light, and remote alarm • Five alarm conditions: High /low temperature, power failure, sensor error, door ajar, low voltage in backup battery Biomedical Blood Bank Refrigerator Light on when LED displaying upper sensor temperature Blood Bank Refrigerator Light on when LED displaying lower sensor temperature A constant light indicates normal power supply, a flashing light indicates power supply failure Both lights on when LED displaying the average temperature of upper and lower temperature The standard drawers can be optionally fitted with adjustable dividers. This guarantees neatly and clearly arranged storage of your goods. HXC-608 Pull down test at 32°C ambient 36 32 28 A flashing light indicates an alarm condition 24 Temperature(°C) To cancel buzzing To adjust the displayed temperature To test alarm function To calibrate upper sensor, lower sensor and control sensor 20 16 12 8 4 0 To select sensor to calibrate 10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160 Time (min) To cancel calibration HXC-608 Pull-up test at 32°C ambient 36 Alarm Alarm Triggering Condition High Temperature Temperature reaches the warm alarm limit Low Temperature Temperature reaches the low alarm limit Power Failure Equipment loses power Probe Failure 1.Main cabinet temperature control sensor fails 2.Condenser sensor fails 3.Ambient sensor fails 4.Heat exchanger sensor fails 32 28 Battery capacity runs low or battery switch is not turned on Door Ajar Door open exceeds 600s 65 20 16 Blood Bank Refrigerator Low Battery Temperature(°C) 24 12 8 4 0 10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160 Time (min) 66 Biomedical Blood Bank Refrigerator Blood Bank Refrigerator Application Advantages 2-6°C Safety Dual-pane electrical heated glass door Multilayer adjustable shelves Baskets or optional stainless steel drawers Each shelf can be labelled E Microprocessor control, three inner fans maintain temperature uniformity within 2~6°C and quick recovery after door openings Defrosting is performed automatically with temperature sensor system, temperature rise during defrost is minimal, further protecting the contents Ergonomic Design Self-closing door It provides a clear view of stored items through the large glass windows Two access ports, users can test the inner temperature freely Built-in 7-day circular chart recorder with USB port Bright, energy-efficient LED interior lighting CFC-free refrigerant, environmental friendly "One lock one key" to safeguard valuable contents 67 48 68 Blood Bank Refrigerator sensor error Blood Bank Refrigerator Biomedical Blood Bank Refrigerator Specification Model HXC-158 HXC-358 Technical Data Performance Control Electrical Data HXC-1308 HXC-158B HXC-608B HXC-358B HXC-1308B Drawer-Type Climate Class ST ST ST N ST ST ST N Cooling Type Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Defrost Mode Refrigerant Noise(dB(A)) Temperature Range( °C) Ambient Temperature (°C) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) Blood Storage Capacity (450ml blood bags) Net/Gross Weight(approx) Dimensions HXC-608 Basket-Type Type Auto Auto Auto Auto Auto Auto Auto Auto CFC-Free 42 2-6 CFC-Free 43 2-6 CFC-Free 43 2-6 CFC-Free 45 2-6 CFC-Free 42 2-6 CFC-Free 43 2-6 CFC-Free 43 2-6 CFC-Free 45 2-6 10-38 10-38 10-38 16~32 10-38 10-38 10-38 16-32 Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED LED LED LED LED LED LED LED 220~240/50/60 220~240/50 /60 220~240/50 /60 115/60 220~240/50 220~240/50/60 220~240/50/60 220~240/50/60 220~240/50 350 460 490 560 850 350 460 490 850 3.5 7.5 2.6 3 4.2 2.6 3 3.5 4.2 158/5.6 358/12.7 608/21.5 1308/46.2 158/5.6 358/12.7 608/21.5 1308/46.2 84 200 312 624 84 200 360 720 107/120(kg) 235.9/264.6(lbs) 158/174(kg) 348.3/383.6(lbs) 204/227(kg) 449.7/500.4(lbs) 310/360(kg) 683.4/793.7(lbs) 113/126(kg) 249.1/277.8(lbs) 165/181(kg) 363.8/399.0(lbs) 211/234(kg) 465.2/515.9(lbs) 335/385(kg) 738.5/848.8(lbs) Interior Dimensions (W*D*H) Exterior Dimensions (W*D*H) 460*370*950(mm) 620*490*1160(mm) 24.4*19.3*45.7(in) 18.1*14.6*37.4(in) 560*570*1530(mm) 720*690*1730(mm) 28.3*27.2*68.1(in) 22.0*22.4*60.2(in) 680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in) 1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in) 460*370*950(mm) 18.1*14.6*37.4(in) 560*570*1530(mm) 22.0*22.4*60.2(in) 620*490*1160(mm) 24.4*19.3*45.7(in) 720*690*1730(mm) 28.3*27.2*68.1(in) 680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in) 1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in) Packing Dimensions (W*D*H) 645*675*1680(mm) 795*805*1870(mm) 31.3*31.7*73.6(in) 25.4*26.6*66.1(in) 865*945*2090(mm) 1570*1010*2120(mm) 61.8*39.8*83.5(in) 34.0*37.2*82.3(in) 645*675*1680(mm) 25.4*26.6*66.1(in) 795*805*1870(mm) 31.3*31.7*73.6(in) 865*945*2090(mm) 34.0*37.2*82.3(in) 1570*1010*2120(mm) 61.8*39.8*83.5(in) 27/54/54 14/30/30 12/26/26 6/12/12 Container load (20'/40'/40'H) 27/54/54 14/30/30 12/26/26 6/12/12 Y Y Y Y Sensor Error Y Y Y Y Y Y Y Y Low Battery Y Y Y Y Y Y Y Y High/Low Temperature Functions Accessories Others Door Ajar Y Y Y Y Y Y Y Y Remote Alarm Y Y Y Y Y Y Y Y Caster Y Y Y Y Y Y Y Y Leveling Leg Y Y Y Y Y Y Y Y Test Hole Y Y Y Y Y Y Y Y 4/4 5/20 6/24 12/48 _ _ _ _ Shelves/Baskets Drawers/Inner doors -/2 -/3 -/3 -/6 4/- 5/- 6/- 12/- USB Interface Optional Optional Optional Y Optional Optional Optional Y Temperature Recorder Optional Y Y Y Y Y Y Y CE CE CE CE CE CE CE CE Certificate Product appearance and specifications are subject to change without notice 69 70 Blood Bank Refrigerator Power Failure Vaccine Storage Solution 71 72 Vaccine & Icepack Freezer Biomedical Vaccine & Icepack Freezer WHO/UNICEF qualified supplier The refrigerators are designed to store vaccine, freeze icepack, pharmaceuticals and so on. Applications could be found in epidemic prevention, clinics,hospitals, research institutes etc. • From 2004 until now, Haier awarded the tender from India MOHFW, WHO, UNICEF, Africa market to supply about 50,000 units icepack freezers and ice-lined refrigerators • 2009, World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116 • 2011, Haier obtained the LTA of Ice-Lined Refrigerator and Vaccine Freezer. Haier is the long term supplier of UNICEF • 2014, Haier broke the European & USA monopoly of the vaccine refrigerator in Africa market -1000 units was awarded by the PFSA Ethiopia HBD-116 HBD-286 Cabinet Type Chest Chest Ambient Temperature <43°C <43°C Cooling Type Direct cooling Direct cooling Defrost Mode Manual Manual CFC-Free CFC-Free Technical Data Refrigerant Noise(dB(A)) HBD-286 HBD-116 Performance Control Refrigeration System Ergonomic Design • Famous brand high quality compressor • CFC-free high density foam insulation • Optimized refrigeration system design • • • • • Temperature Control Electrical Data HBD-286 Pull down test at 43 °C ambient HBD-286 Pull-up test at 43 °C ambient 50 43 30 20 20 Temperature Temperature 30 0 -10 -20 43 40 Dimensions Mechanical LCD LCD 220~240/50 Power(W) 138 166 185 Electrical Current(A) 1.05 1.65 1.3 Power Consumption: stable running(KWh/24h) 3.01 3.53 3.48 Power Consumption: cool down test(KWh/24h) 3.25 3.25 3.71 more than 3hrs(up to -5°C) more than 5hrs(up to -5°C) Vaccine Storage Capacity(L/Cu.Ft) 97/3.4 258/9.1 Gross Volume(L/Cu.Ft) 121/4.3 286/10.1 waterpack freezing capacity 12kg/24h 16.8kg/24h waterpack storage capacity 136*0.6L 310*0.6L Interior Dimensions(W*D*H) Packing Dimensions(W*D*H) -10 Mechanical 208~230/60 Exterior Dimensions(W*D*H) 0 44 -15~-25 220~240/50 Net/Gross Weight(approx) 10 43 -15~-25 Display Holdover Time at 43°C 50 10 Controller Power Supply(V/Hz) Safety lock for unauthorized access Corrosion-proof interior and ease of cleaning Shelving designs for various sizes of storage baskets Drainage system for ease of cabinet cleaning LCD temperature display • Digital display • Inner temperature range is -15°C to -25°C 40 Temperature Range(°C) -20 50/55(kg) 110.3/121.3(lbs) 79/85(kg) 174.2/187.4(lbs) 497*457*655(mm) 19.6*18.0*25.8(mm) 1067*457*655(mm) 42.0*18.0*25.8(in) 670*630*818(mm) 26.4*24.8*32.2(in) 1240*630*818(mm) 48.8*24.8*32.2(in) (Paper)755*760*880(mm) 29.7*29.9*34.6(in) (Paper)1325*760*880(mm) 52.2*29.9*34.6(in) (Wooden)820*820*1045(mm) 32.3*32.3*41.1(in) (Wooden)1375*820*1045(mm) 54.1*32.3*41.1(in) 28/56/56(Wooden) 24/54/81(Paper) -30 Container load (20'/40'/40'H) -40 -40 Foot Y Y -50 -50 Baskets 2 3 CE,WHO/PQS CE,WHO/PQS -30 0 05 10 15 20 25 30 35 40 45 50 55 60 Time (H) Accessories 0 05 10 15 20 25 30 35 40 45 Time (H) 73 50 55 60 Others Certificate 42/90/135(Paper) 74 16/32/32(Wooden) Vaccine & Icepack Freezer Model Biomedical Ice-Lined Refrigerator Ice-Lined Refrigerator Refrigeration System • Optimized refrigeration system design • Built-in ice packs maintain 2°C to 8°C for more than 25 hours at 43°C ambient • CFC-free high density foam insulation • Complied with WHO/UNICEF standards Temperature Control • Digital temperature display • Inner temperature range is 2°C to 8°C Technical Data Ergonomic Design • Door lock for storage safety • Stainless steel interior for ease of cleaning and corrosion proof Performance Control Electrical Data 1.34 4.01 27hrs18mins 36hrs17mins 31hrs24mins 53 Functions Accessories Others Product appearance and specifications are subject to change without notice 75 76 Ice-Lined Refrigerator Dimensions For Solar-powered Vaccine Refrigerator, electricity and fuel are unneeded. It provides with convenience to store vaccine for the areas without power or power unstable regions, especially frequent blackout. This kind of refrigerator can also be used for vaccine storage in developing countries. Haier has repeatedly taken part in the project of children health protecting in WHO,UNICEF, Africa and other developing regions, providing the solutions of vaccine storage security. Solar Direct Drive Vaccine Refrigerator Model WHO/UNICEF qualified supplier Haier successfully won the UNICEF tender of 100 units SDD Refrigerator HTC-60H for aiding North Korea project . 2014 Haier has been awarded 1,000 units SDD Vaccine Refrigerator of HTC-60H PO from MOH of Ethiopia. Technical Data Cabinet Type Chest Ambient Temperature(°C) 5~43°C Cooling Type Forced air cooling Refrigerant Performance Storage Security Control The product using ambient temperature 5~43°C Forced air cooling system designed to provide stable and uniform chamber temperature LCD temperature display to read the visual temperature High and low temperature and sensor error alarm system,multiple built-in protection system Corrosion-resistant stainless steel liner Lock design, safe to storage the vaccine Keeping inside temperature at 2-8°C, in the condition that ambient temperature is 43°C power outage for 110 hours , safe for vaccine storage HTC-60H HTC-60H Electrical Data Temperature Control Microcomputer control, guarantee the accurate temperature Temperature measurement function, the temperature inside chamber is accordance with the display temperature Ergonomic Design Solar-driven, green and environment friendly Temperature controller is easy to view, ancillary battery for display without sunshine Low noise CFC-Free Noise ( dB(A)) 30 Temperature Range(°C) 2~8 Controller Microprocessor Display LCD temperature display Power supply(VDC) 12 Maximal Current(A) 6 Energy Consumption:stable running(KWh/24h) 0.78 Energy Consumption:cool down test(KWh/24h) 0.67 Holdover time at 43°C 109hrs 21mins Autonomy Time 110hrs 37mins Solar Radiation Reference Period 3.5kwh/㎡/day Voltage of Solar Panel 12V Power of Solar Panel 120W*3 Vaccine Storage Capacity(L/Cu.Ft) 21/0.7 Gross Volume(L/Cu.Ft) 60/2.1 Net/Gross Weight(approx) EXTERNAL DIGITAL DISPLAY The current temperature is digital display. There is no need for daily adjustment, as the entire system has been calibrated before delivery from the factory and it is self-regulating. Dimensions 88/110(kg) 194/243(lb) Interior Dimensions(W*D*H) 245*450*610(mm) 9.6*17.7*24.0(in) Exterior Dimensions(W*D*H) 788*654*875(mm) 31.0*25.7*34.4(in) Packing Dimensions(W*D*H) 865*770*1080(mm) 34.1*30.3*42.5(in) Container load(20'/40'/40'H) Cooling curve at ambient temperature of 43℃ 50 50 43℃ Temperature(℃) Temperature(℃) 96hrs 20 10 8℃ 40 30 109hrs21mins 19 31 43 55 67 81 93 96 10 8℃ 2℃ 12 Time(H) Y Sensor Error Y Low Battery Y Accessories Baskets 2 Others Certificate Alarm 0 7 High/Low Temperature 20 2℃ 0 1470*680*35(mm) 57.8*26.8*1.4(in) Solar Panel(L*W*D) 43℃ 40 30 36/78/78 Holdover time curve at ambient temperature of 43℃ 24 36 48 60 72 84 96 CE/WHO/PQS 109 Time(H) 77 78 Solar Direct Drive Vaccine Refrigerator Solar Direct Drive Vaccine Refrigerator Biomedical Solar Direct Drive Combined Refrigerator/Freezer Solar Direct Drive Combined Refrigerator/Freezer Model Technical Data HTCD-160 Cabinet Type Upright Ambient Temperature(°C) 5~43°C Direct cooling Cooling Type Manual Defrost Mode(Freezing Chamber) CFC-Free Refrigerant 38 Noise (dB(A)) Temperature Range(°C) Display panel Cooling Chamber Vaccine Storage Capacity(L/Cu.Ft) Performance Freezing Chamber Control Electrical Data HTCD-160 Handgrip 120/4.2 Temperature Range(°C) ≤-10 Gross volume (L/Cu.Ft) 40/1.4 Waterpack storage capacity(kg) 10.68 Controller Temperature control The internal temperature of the cooling chamber is not lower than 0°C due to its anti-freeze function. Under ambient temperature of 43 degrees, the inner box temperature will be no more than 8°C after power outage for more than 121 hours and no more than 10°C after power outage for more than 160 hours, so as to guarantee safe storage of vaccine. The freezing chamber can freeze 2.08kg of ice every day, with storage of 10.68kg in total. Solar energy temperature display,clear temperature in the inner box. Lock catch designed to match padlock Cooling chamber meet the A level WHO requirements of anti-freezing protection. Microprocessor Control; guarantee temperature precision. Ergonomic Design Display Solar LED temperature display Power supply(VDC) 24 Maximal Current(A) 9 Energy Consumption:stable running(KWh/24h) 0.86 Energy Consumption:cool down test(KWh/24h) 0.86 Holdover time at 43°C 160hrs8mins Autonomy Time 121hrs27mins Solar Radiation Reference Period 3.5kwh/㎡/day Voltage of Solar Panel 24V Power of Solar Panel 255W*3 Equipped with USB charging socket , for charging the mobile phone,etc Eliminate storage battery and only provide solar energy power, which is green and friendly environment. There is illumination on temperature display screen,it can display the inner box temperature even though it is powered off, which is convenient for administration. The refrigerating chamber and freezing chamber both have the separate refrigerating systems; the two independent refrigerating systems ensure safety of the vaccine storage. Sensor error alarm. Low noise. 79 160/186(kg)353/410(lb) Freezing Chamber 560*520*150(mm) 22.0*20.5*5.9(in) Cooling Chamber 545*500*530(mm) 21.4*19.7*20.8(in) Interior Dimensions(W*D*H) Dimensions Exterior Dimensions(W*D*H) 865*825*1695(mm) 34.1*32.5*66.7(in) Packing Dimensions(W*D*H) 960*890*1860 (mm) 37.8* 35.0*73.2(in) Container load(20'/40'/40'H) 12/26/26 1640*990*35(mm) 64.6*39.0*1.4(in) Solar Panel(L*W*D) Alarm Accessories Others 2.08kg/24h Microprocessor Net/Gross Weight(approx) Storage Security 100/3.5 Gross Volume(L/Cu.Ft) Waterpack freezing capacity(kg/24h) Lock catch designed to match padlock 2~8 Sensor Error Y Shelves 2(Cooling Chamber) Certificate CE/WHO/PQS 80 Solar Direct Drive Vaccine Refrigerator Biomedical Solar Direct Drive Vaccine Refrigerator Model HTC-40 HTC-110 Chest Chest 5~43°C 5~43°C Cooling Type Direct cooling Direct cooling Defrost Mode / / CFC-Free CFC-Free Noise ( Db(A)) <30 <30 Temperature Range(°C) 2~8 2~8 Microprocessor Microprocessor Solar LED temperature display Solar LED temperature display Power supply(V) 24 24 Maximal Current(A) 5 5 Energy Consumption:stable running(KWh/24h) 0.69 0.58 Energy Consumption:cool down test(KWh/24h) 0.71 0.62 Holdover time at 43°C 122hrs18mins 106hrs17mins Autonomy Time 117hrs18mins 96hrs24mins Solar Radiation Reference Period 3.5kwh/㎡/day 3.5kwh/㎡/day Voltage of Solar Panel 24V 24V Power of Solar Panel 180W *2 180W *2 Vaccine Storage Capacity(L/Cu.Ft) 22.5(0.8) 59 (2.08) Gross Volume(L/Cu.Ft) 40L(1.4) 110L(3.88) 55/75(121/165) 69/92(151/202) Interior Dimensions(W*D*H) 200*345*575(mm) 545*345*575 (mm) Exterior Dimensions(W*D*H) 788*645*875(mm) 1128*645*875(mm) Packing Dimensions(W*D*H) 835*770*1080 (mm) 1175*770*1080 (mm) Container load(20'/40'/40'H) 36/78/78 30/60/60 1335*990*40(mm) 52.5*39*1.57 1335*990*40(mm) 52.5*39*1.57 High/Low Temperature N N Sensor Error Y Y Low Battery / / Baskets 2 4 Shelves - - CE/WHO/PQS CE/WHO/PQS Data Logger Y Y Freezer Protection Level A A Freezer Gross Volume (L): - - Waterpack Storage Capacity(kg) - - Waterpack Freezing Capacity(kg/24h) - - Cabinet Type Ambient Temperature(°C) This product is designed to store vaccine, reagents, etc. Applicable to the sunny and power shortage remote area. Technical Data Refrigerant Performance Control Solar energy display panel Display Electrical Data HTC-40 Net/Gross Weight(approx) HTC-110 Dimensions Product features Solar direct drive,green and environment-friendly Microprocessor control, solar energy display panel for showing interior temperature Water tank for keeping interior temperature, holding time is longer when power off Cooling chamber meet the A level WHO requirements of anti-freezing protection Patented technology, better temperature uniformity Inner door offer additional temperature protection Wide temperature range, working normally at 5-43°C ambient Solar Panel(L*W*D) Functions Accessories Ergonomic design Safety lock for unauthorized access control Equipped with USB charging socket,for charging the mobile phone, etc Equipped with storage basket, easy-reach retrieval of samples Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with handles on both sides of the cabinet, easy to move 81 Controller Certificate Others 82 Solar Direct Drive Vaccine Refrigerator Solar Direct Drive Vaccine Refrigerator Biomedical Solar Direct Drive Vaccine Freezer Model This product can be used to freeze ice pack, applicable to the sunny and power shortage remote area. Technical Data HTD-40 Cabinet Type Chest Ambient Temperature(°C) ≤43°C Cooling Type Direct cooling Defrost Mode Manual CFC-Free Refrigerant Performance Control Electrical Data Noise ( Db(A) ) <30 Temperature Range(°C) ≤-10 Microprocessor Controller Solar LED temperature display Display Power supply(V) 24 Maximal Current(A) 5 Energy Consumption:stable running(KWh/24h) 0.46 Energy Consumption:cool down test(KWh/24h) 0.50 Holdover time at 43°C - Autonomy Time - Solar Radiation Reference Period Solar energy display panel Voltage of Solar Panel 24V Power of Solar Panel 180W *2 Vaccine Storage Capacity(L/Cu.Ft) Product features Solar direct drive, green and environment-friendly Solar energy display panel for showing interior temperature, the interior temp less than -10°C High-performance refrigeration Wide temperature range, working normally less than 43°C ambient Heavy insulation layer, high-efficiency of heat insulation Safety lock for unauthorized access control Equipped with storage basket, easy-reach retrieval of samples Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with USB charging socket, for charging the mobile phone, etc Interior Dimensions(W*D*H) 265*370*575(mm) Exterior Dimensions(W*D*H) 788*654*875(mm) Packing Dimensions(W*D*H) 835*770*1080 (mm) Container load(20'/40'/40'H) 36/78/78 1335*990*40(mm) 52.5*39*1.57 Solar Panel(L*W*D) Functions Accessories Ergonomic design 65/85(143/187) Net/Gross Weight(approx) Dimensions High/Low Temperature N Sensor Error Y Low Battery / Baskets 2 Shelves CE/WHO/PQS Certificate Others Data Logger - Freezer Protection Level / Freezer Gross Volume (L): 48(1.7) Waterpack Storage Capacity(kg) 16.8kg Waterpack Freezing Capacity(kg/24h) 83 48(1.7) Gross Volume(L/Cu.Ft) HTD-40 3.5kwh/㎡/day 84 2.4 kg/24h Solar Direct Drive Vaccine Refrigerator Solar Direct Drive Vaccine Freezer Biomedical Solar Direct Drive Combined Refrigerator/Freezer Solar Direct Drive Combined Refrigerator/Freezer Model The refrigerator with freezer combination, this product can be used to store vaccine, reagent and freeze ice pack. Applicable to the sunny and power shortage remote area. Technical Data HTCD-90 Cabinet Type Chest Ambient Temperature(°C) 5~43°C Cooling Type Direct cooling Defrost Mode Manual CFC-Free Refrigerant <38 Noise (Db(A) ) Performance Control Electrical Data Solar energy display panel freezer ≤-10 refrigerator:2~8 Temperature Range(°C) Microprocessor Controller Solar LED temperature display Display Power supply(V) 24 Maximal Current(A) 7 Energy Consumption:stable running(KWh/24h) 0.86 Energy Consumption:cool down test(KWh/24h) 0.81 Holdover time at 43°C 137hrs47mins Autonomy Time 114hrs56mins Solar Radiation Reference Period 3.5kwh/㎡/day Voltage of Solar Panel 24V Power of Solar Panel 180W *4 Vaccine Storage Capacity(L/Cu.Ft) 37.5 (1.3) freezer:32 (1.1) Gross Volume(L/Cu.Ft) HTCD-90 refrigerator:58L (2.1) 83/108(183/238) Net/Gross Weight(approx) Product features Dimensions The refrigerating chamber and freezing chamber both have the separate refrigerating systems; the two independent refrigerating systems ensure safety of the vaccine storage Solar direct drive,green and environment-friendly Microprocessor control, solar energy display panel for showing refrigerator and freezer interior temperature, refrigerator temperature range is 2~8°C, freezer temperature is less than -10°C Cooling chamber with water tank for keeping interior temperature, holding time is longer when power off Cooling chamber meet the A level WHO requirements of anti-freezing protection Patented technology, better temperature uniformity Wide temperature range, working normally at 5-43°C ambient Safety lock for unauthorized access control Equipped with USB charging socket, for charging the mobile phone, etc Equipped with storage basket, easy-reach retrieval of sample Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with handles on both sides of the cabinet, easy to move Freezer chamber:170*370*575(mm) Exterior Dimensions(W*D*H) 1128*654*875(mm) Packing Dimensions(W*D*H) 1175*770*1080 (mm) Container load(20'/40'/40'H) 30/60/60 1335*990*40(mm) 52.5*39*1.57 Solar Panel(L*W*D) Functions Accessories Ergonomic design Cooling chamber:270*345*555(mm) Interior Dimensions(W*D*H) High/Low Temperature N Sensor Error Y Low Battery / Baskets 4 Shelves CE/WHO/PQS Certificate Others Data Logger Y Freezer Protection Level A Freezer Gross Volume (L): 32(1.1) Waterpack Storage Capacity(kg) 12.52kg Waterpack Freezing Capacity(kg/24h) 85 86 2.43kg/24h Solar Direct Drive Vaccine Refrigerator Biomedical Walk-In Cold/Freezer Room Walk-In Cold/Freezer Room Integral Cold Store Unit • The cold room is suitable to freeze or refrigerate relevant articles for medical service, scientific research,agricultural, biological and chemical industries, etc. Its interior tempera- ture can be controlled respectively within the range of 0~10°C or 0~-25°C Haier walk-in cold room is for storage of vaccines, and the complete unit is also designed for installation in a housed area such as a warehouse in order to meet designed temperature standards. Haier’s WICs & WIFs have passed WHO / PQS and is long term supplier of UNICEF. The units have been installed in India, Guinea, South Sudan, Pakistan, Burundi, Uzbekistan, etc. Features of the Cold Room • The cold room for vaccines and medicines is controlled and adjustable within the range of 0~10°C or -15~-25°C with resolution of 0.1°C • Insulation material CFC-free polyurethane foamed-inpiece, density 42kg/cbm • Insulation thickness 100 mm, K-value 0.22 W/m2K or better Internal and external surfaces of hot-dipped galvanized steel sheet,white polyester coating and floor clad with non-slip material • Rooms equipped with tungsten lighting and with an external switch with pilot lamp • Rooms equipped with shelving system on three walls, material stove enameled steel, galvanized steel,stainless steel, aluminum or plastic slatted adjustable shelving units to carry vaccine in packages, 5 levels, 450-600 mm deep, adjustable • Dual refrigeration system is equipped. When one set of system is working, the other system is for backup • Forced air-cooled condenser refrigeration units • Door equipped with heavy duty hinges and lock with internal safety release. Automatic defrosting CFC-free refrigerant • System to be offered with manual change over switch as standard • Temperature recorder and audible alarm system Technical Characteristics of the Refrigerating Unit • The LYJ series of machine, called mono block, that integrates evaporator, condenser, compressor, electrical control units into one compact body, can be widely used for cold storage rooms of temperature of -5°C~5°C or -15°C~-20°C, in hotels, restaurants, medicines, agricultural, chemicals industries all other place where cold storage is needed. This series products feature below • With very compact structure • With TECUMSEH hermetic compressors, high efficient in-grooved copper tube and aluminum fin heat exchangers and world famous brand refrigeration parts for all products • The electronic control boards are with functions of automatic temperature set, control, and electric heater defrosting.Protection devices for over loading, over heating, lack of phase, high & low pressure etc • Safe, easy, and low cost for installation and operation Freezer Room HRZK-40D HRZK-20D Power(W) 5300 2630 Refrigeranting Output(W) 4200 2060 40 20 Model Defrost Mode Refrigerant Internal Temperature Range(°C) Evaporator Temperature(°C) Power Supply(V/Hz) Capacity(m3) Temperature Recorder • Upper and lower limits +50°C to -30°C • Accuracy ±1°C • Resolution ±0.5°C • Minimum acceptable recording period between chart changes is 7 days • USB interface is equipped Condensation Temperature(°C) Density(Kg/Cbm) K-Value(m2K) Separate Design Insulation Thickness(mm) Certificate •Haier walk-in cold/freezer room can separately design according to the site situation and construction drawings _ 87 88 89 90 Biological Safety Cabinet Biological Safety Cabinet Biological safety cabinet is designed to protect operator, laboratory environment and samples from being exposed to the infective aerosol produced when the sample is bacteria strains, diagnostic material, and other infective subjects. It provides the operators with a more comfortable and safer working condition. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring. And it has been the important basis of sample safety and environment security. Patent Intelligent Constant Air Velocity The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system Low Noise Safety Energy-saving Mode When the human body detecting module detects under the intelligent mode that the person is outside the operating area for over 15 minutes, the microcomputer program will automatically switch the safety cabinet to Low Noise Safety energy conservation mode, so as to realize noise reduction and energy conservation and to improve the service life of the filter Ultra Low Penetration Air Filter System Professional Air-flow Distribution Module Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise <62dBA Camfil ULPA filter Ultra Low Penetration Air Filter System Intelligent constant air velocity patent technology Sweden Camfil (ULPA)filter are tested to a typical efficiency of > 99.999% for 0.12 micron particles. ULPA Filter provides vertical laminar flow to the worktable, so as to protect samples from pollution The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system Patent Technology of Air Flow Disruption Adopt the patent technology of air flow disruption on the upper edge and both sides of the front window (Patent No. ZL200520125549.X) to eliminate the safety protection blindness. Adopt the patent technology of side air flow disruption design to eliminate the exposure of microorganism 304 stainless steel operation platform and internal wall Stainless steel operation platform without screws, no accumulation of contaminant Dismountable air in-flow plate, easy to clean and disinfect Concaved operation platform, waste liquid easily collected Unique Drop-down Front Glass Window HR1200-IIA2 Digital microprocessor control system Remove the hand-placing frame by hand, and pull down the front glass window to clean the upper part of the glass and to avoid dead corners Dismountable Platform-type Hand-placing Frame Platform-type hand-placing frame is comfortable to use and helps to relieve fatigue LCD display Real-time display of key parameters: downflow velocity, inflowvelocity, airflow volume, static pressure, negative pressure,accumulative running time of fan and UV lamp, left lifetime of filter Sound & light alarming function UV sterilization reservation setting function Professional air flow distributiondesign Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise 〈62dBA 91 V-shaped air inlet design Swivel caster, Internal thread support leg CFDA 92 Biological Safety Cabinet Biological Safety Cabinet 304 Stainless Steel Operation Platform and Internal Wall American AAF ULPA filter are tested to a typical efficiency of >99.999% for 0.12 micron particles Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy Digital microprocessor control system for easy operation Intelligent alarming system Multiple interlocking functions eliminate potential safety problems caused by misoperation. Removable stainless steel work surface makes cleaning easier Stainless steel operation platform without screws, no accumulation of contaminant Dismountable air in-flow plate, easy to clean and disinfect Internal wall is constructed by a single plate, and the12mm arc angle conner leaves no cleaning blind area The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintaining Concaved operation platform, waste liquid easily collected Adjustable supporter (0-75mm) without exposed screw thread, preventing the germs from multiplying Ultra Low Penetration Air Filtration System American AAF ULPA filter Tested to a typical efficiency of 99.9995% for 0.12 micron particles Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection High Efficiency Blower System Ergonomic angled design to improve comfort The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance Self cooling system reduces energy consumption while enhancing reliability Adjustable foot HR40-IIA2 Reverse centrifugal fan 93 Double-side air inflow design decreases running noise Air velocity auto-compensation function guarantees stable wind speed 94 Provide uniform airflow by adjusting working voltage of fan Biological Safety Cabinet Working Voltage& Frequency Biological Safety Cabinet 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz Power(VA) 1400 1500 1300 1300 1300 1300 1500 Power of Blower(W) 335 475 650 350 350 650 505 Airflow Circulation 70% downflow,30% exhaust 70% downflow,30% exhaust 70% downflow,30% exhaust 70% downflow, 30% exhaust 70% downflow, 30% exhaust 70% downflow, 30% exhaust 100% exhaust Main Filter Typical Effiency ULPA,99.9995%@0.12um ULPA,99.9995%@0.12um ULPA,99.9995%@0.12um ULPA,99.9995%@0.12µm ULPA,99.9995%@0.12µm ULPA,99.9995%@0.12µm ULPA,99.9995%@0.12µm Exhaust Filter Typical Effiency ULPA,99.9995%@0.12um ULPA,99.9995%@0.12um ULPA,99.9995%@0.12um ULPA,99.9995%@0.12µm HEPA,99.995%@0.3µm ULPA,99.9995%@0.12µm HEPA,99.99%@0.3µm Camfil Camfil AAF AAF AAF AAF AAF Downflow Velocity(m/s) 0.33 0.34 0.31 0.31 0.28 0.28 0.28 Inflow Velocity(m/s) 0.55 0.55 0.55 0.55 0.55 Fluorescent Lamp Intensity(Lux) 900 900 900 ≥1100 ≥1100 290/315(kg) 639.3/694.5(lbs) 320/347(kg) 705.4/765(lbs) 350/375(kg) 771.6/826.7(lbs) 220/248(kg) 485.0/546.7(lbs) 258/293(kg) 568.8/646.0(lbs) Internal Dimensions(W*D*H) 920*620*650(mm) 36.2*24.4*25.6(in) 1220*620*650(mm) 48.1*24.4*25.6(in) 1520*620*650(mm) 59.9*24.4*25.6(in) 900*610*680(mm) 35.4*24.0*26.8(in) External Dimensions(W*D*H) 1080*845*2160(mm) 42.5*33.3*85.0(in) 1380*845*2160(mm) 54.3*33.3*85.0(in) 1680*845*2160(mm) 66.2*33.3*85.0(in) Packing Dimensions(W*D*H) 1145*920*1690(mm) 69.1*36.2*66.5(in) 1470*920*1690(mm) 57.9*36.2*66.5(in) 75mm adjustbale height Filter's Brand Net/Gross Weight Supporter Container load (20'/40'/40'H) Alarm Certificate 0.55 0.55 ≥1100 1167*610*680(mm) 45.9*24.0*26.8(in) ≥1100 340/380(kg) 749.5/837.8(lbs) 1585*610*680(mm) 62.4*24.0*26.8(in) 1167*610*680(mm) 46.0*24.0*26.8(in) 1100*790*2200(mm) 43.3*31.1*86.6(in) 1360*790*2200(mm) 53.5*30.7*86.6(in) 1780*790*2200(mm) 70.1*31.1*86.6(in) 1360*790*2400(mm) 53.5*31.1*94.5(in) 1755*920*1690(mm) 69.1*36.2*66.5(in) 1160*920*1690(mm) 45.7*36.2*66.5(in) 1420*920*1690(mm) 55.9*36.2*66.5(in) 1840*920*1690(mm) 72.4*36.2*66.5(in) 1420*920*1850(mm) 55.9*36.2*72.8(in) 75mm adjustbale height 75mm adjustbale height 75mm adjustable height 75mm adjustable height 75mm adjustable height 75mm adjustable height 12/24/24 8/16/16 6/12/12 10/20/20 8/16/16 4/10/10 8/16/16 Sound and Flash Sound and Flash Sound and Flash Sound and Flash Sound and Flash Sound and Flash Sound and Flash CE,EN12469,CFDA CE,EN12469,CFDA CE,EN12469,CFDA CFDA EN12469,CFDA,CE CFDA CFDA 280/308(kg) 617.3/694.5(lbs) Product appearance and specifications are subject to change without notice 95 96 High-efficiency Filter ULPA The world-famous AAF damp and fire resistant fiberglass high-efficiency air filter (HEAP) 99.99%@0.3µm, enjoys the cleaning class up to Class V, ISO14644.1 which is superior to the cleaning requirement of class 100, safer and cleaner Featuring many patented technologies and authoritative testing certification for reliability Microcomputer intelligent control panel with durable touch buttons Multiple safety protection functions including UV delay start Interlocking function to put an end to incorrect operation Various personalized design to ensure comfortable operation Perfect memory function to avoid repeat setting Combined under-frame structure with universal truckle design 304 Stainless Operation Table The excellent 304 stainless operation table without fixing screws can avoid the accumulation of dirt Ergonomic Design • Adopting recess lighting to eliminate the radiation of the fluorescent lamps on the eyes and thus preventing the eyes from being tired • Equalizer bar design: In the working area, the stainless equalizer bar with hooks is provided for facilitating the movement of articles Patented Technology High-efficiency Filter ULPA • UV sterilization startup delay (keep away the injury by UV light) patent technology (ZL201220087011.4), After the UV lamp switch is pressed down, the audible and visual alarm will be activated to remind the operator to leave in time. After 10s, the UV light is on. Therefore, the operator can be protected from the injury by UV light • Preset function: It can preset the UV sterilization startup delay to provide users with more rest and to improve working efficiency, possessing the patent technology (ZL201220087011.4) Interlocking Function Shell : Cold rolled electrostatic painting, anti -corrosion ability With the interlocking between illuminating lamp and UV lamp, the UV lamp can become on only when the illuminating lamp is off; When the UV lamp is on, it can be off if pressing the daylight lamp. The risk of incorrect operation can be avoided Memory Function The UV lamp startup delay time, sterilization duration, preset start time, fan position can be set and saved by user on request for the convenience of startup UV Lamp One-key Preset UV germicidal delayed start to prevent from away UV damage One-key Operation • After the UV lamp switch is pressed, the time function can be activated automatically. The default sterilization time is 30min, which can be adjusted by user within 0~99min on request • Sterilization preset, when pressing the UV lamp, the preset lamp will become on to remind user that the sterilization preset function has been activated and that the sterilization preset can be conducted Pre-cleaning Function Pre-cleaning Function: patented technology (ZL201220087011.4) 304 Stainless Operation Table UV lamps , fans, lighting linkage system to enhance user 97 Universal Caster to move more conveniently Flow Type Voltage/Frequency Power Vibration Amplitude Exhaust Filter Typical Efficiency Average Velocity Fluorescent Lamp Intensity Net/Gross Weight Noise(dB(A)) Internal Dimension(W*D*H) External Dimension(W*D*H) Packing Dimension(W*D*H) Supporter Cleanliness Classification Container Load(20'/40'/40'H) Certificate HCB-900V HCB-1300V Vertical 220V/50Hz 1200W ≤2um HEPA,99.99%@0.3um 0.2~0.5m/s ≥400 Lux 115/140(kg) 254/309(lbs) ≤60dB 900*550*520(mm) 35.4*21.7*20.5(in) 970*630*1730(mm) 38.2*24.8*68.1(in) 1105*745*1280(mm) 43.5*29.3*50.4(in) 750mm high chassis ISO14644.1 Class 5 7/30/15 CFDA Vertical 220V/50Hz 1200W ≤2um HEPA,99.99%@0.3um 0.2~0.5m/s ≥600 Lux 145/175(kg) 320/386(lbs) ≤60dB 1300*550*520 (mm) 51.2*21.7*20.5(in) 1370*630*1730(mm) 53.9*24.8*68.1(in) 1505*745*1280(mm) 59.3*29.3*50.4(in) 750mm high chassis ISO14644.1 Class 5 3/30/15 CFDA 98 Clean Bench The only pre-cleaning function can further improve the protection on sample 99 100 Liquid Nitrogen Container Liquid Nitrogen Container Product Details Haier Liquid Nitrogen Storage System Biobank Series Top of the Container Lid Open Biobank Series has six models with capacity of 300, 500, 800, 1000, 1500, and 1800. Biobank Series is designed to ensure the maximum storage capacity with the minimum consumption of liquid nitrogen to lower the overall cost of operations. Product Advantages Optimal Use of Storage Space Racks are stored on the rotating tray with an appropriate distance from the wall of the chamber. Liquid nitrogen or supercooled nitrogen vapor is filled in the space between the tray and the wall to maintain temperature uniformity. Storage space is equally divided into four or six fan-shaped storage rooms which are clearly labeled. Each storage room is easily rotated to the opening of the tank for convenient sample access. Advanced Vacuum Technology and Superinsulation Technology Haier Liquid Nitrogen Storage System Biobank Series applies advanced vacuum technology and superinsulation technology to ensure storage safety and temperature uniformity while reducing the consumption of liquid nitrogen. The temperature difference of the entire storage area does not exceed 10°C even in vapor phase storage, and temperature near the top of the shelf can be as low as -190°C. Designed for Both Liquid and Vapor Phase Storage Each model of Biobank Series is designed for both liquid and vapor phase storage. For vapor phase storage, samples are kept away from the liquid nitrogen while stored in a uniform temperature that is close to the temperature range of liquid nitrogen. Cryosmart Intelligent Liquid Nitrogen Control System Haier Liquid Nitrogen Storage System Biobank Series features Cryosmart system for complete monitoring and controlling. High-precision temperature and liquid level censors are used to ensure accuracy. All data and samples are protected by secure access control system. A Low-temperature hose connects the inlet and liquid nitrogen tank for supplement. A silencer reduces the noise of nitrogen emission to grant a quiet environment. Vapor condensation near the container opening is controlled. The strength of the container is reinforced at liquid nitrogen temperature to extend service life. Features • Massive capacity between 13000 to 94875 ×2ml Vials. • One-touch defogging for easier access. • Vapor phase storage is the only guaranteed method to prevent cross-contamination • LN splash proof make the operation more secure. • Vapour phase storage at -190°C. • Biobank storage compatible. • 5 year vacuum warranty 101 102 Small self-pressurized liquid nitrogen supply system suitable for research institutes dealing with fewer samples. Distribution of Racks and Holders Distribution of Racks and Holders Technical Parameters Model YDD-300-326 YDD-800-460 YDD-500-440 YDD-1000/ 1500/1800-635 YDD-300 -326 YDD-800 -460 YDD-1000 -635 YDD-1500 -635 YDD-1800 -635 Maximum Storage Capacity 2 ml Vials (Internal Thread) 13000 26000 42900 58500 76050 94875 12 24 32 54 54 60 4 8 4 18 18 13 10 10 13 10 13 15 18200 36400 58100 81900 99450 126500 Freeze Rack (100 wells) Freeze Rack (25 wells) 12 24 32 54 54 60 4 8 4 18 18 13 Layers of each rack 14 14 17 14 17 20 Freeze Rack (100 wells) Freeze Rack (25 wells) Layers of each rack Holders YDD-500 -440 0.5 ml Vials (Internal Thread) Capacity Internal Capacity Volume of LN under the tray (L) Static Evaporation (%/Day) 25 ml Racks 350 590 890 1340 1660 1880 55 80 135 265 300 320 ≤1.92 ≤1.35 ≤0.85 ≤1.15 ≤0.78 ≤0.69 Dimensions Inside Neck Diameter (MM) Height (MM) Operating Height (MM) Outside Diameter (MM) Door Width Requirements (MM) Empty Weight (KG) Gross Weight (KG) 50 ml Racks 326 440 460 635 635 635 1326 1321 1559 1404 1589 1883 1263 1266 980 997 967 1097 870 1080 1180 1565 1565 1565 1000 1200 1300 1700 1700 1700 219 328 441 851 914 985 502 805 1160 1934 2255 2504 Total Total Total Total Total Total No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of Layers Racks Layers Racks Layers Racks Layers Racks Layers Racks of of of of of of Layers Racks Bags Bags Bags Bags Bags Bags 250 ml Racks 103 25 ml 1272 6 212 2376 6 396 3360 7 480 4716 6 786 5502 7 786 7758 9 862 50 ml 792 6 132 1416 6 236 2016 7 288 2916 6 486 3402 7 486 4905 9 545 250 ml 288 3 96 552 3 184 4 236 1950 4 390 1950 5 390 2095 5 419 944 104 Distribution of Racks and Holders Blood bag capacity Liquid Nitrogen Container Biomedical Liquid Nitrogen Container Technical Parameters Model YDS-65-216-F YDS-95-216-F YDS-115-216-F YDS-140-216-F YDS-175-216-F Maximum Storage Capacity Haier Liquid Nitrogen Storage System Medical Series features low LN consumption and relatively small footprint for medium capacity sample storage. Product Advantages ULT Storage with Extremely Low LN Evaporation Freezer racks are in the ultra-low temperature environment with extremely low LN evaporation. Even stored in vapor phase, the temperature will be below -190°C for a long time. Advanced Vacuum Technol ogy and Superinsulation Technology Advanced vacuum and insulation technologies ensure cryopreservation for as long as four months. Compatible for Blood Bag Storage According to users’ needs, Medical Series can be adapted to LN tanks for temporary storage of blood bags before transferred to larger scale LN storage. No. of holders 2 ml Cryovials (100 per box) No. of boxes in (2ml each holder) 5 ml Cryovials (36 per box) No. of boxes in (5ml each holder) 6 6 6 6 6 2400 3000 3600 4800 6000 4 5 6 8 10 648 864 1080 1296 1728 3 4 5 6 8 Capacity Volume of LN (L) Static Evaporation* (L/Day) Working Volume Duration of Normal** Operation (Day) 65 95 115 140 175 0.79 0.81 0.83 0.87 0.87 55 85 105 130 165 44 66 80 94 126 Dimensions Auto-Refill System Auto-refill system is particularly suitable for vapor phase storage. For liquid phase storage, it can also facilitate users’ operations by avoiding frequent refills. The auto-refill system continuously monitors the inside temperature through ZTC-100B/100C Level Monitor, and automatically controls inlet valve to replenish LN. Although less economical, it provides accurate control and ensures safety storage for over 8 weeks. 216 216 216 216 216 Height(MM) 710 726 796 910 1026 Outside Diameter(MM) 681 681 681 681 681 Empty Weight(KG) 27.5 34.5 38.5 42.5 55 Gross Weight(KG) 80.8 112.4 132.8 157.3 198.5 * Static evaporation and static holding time is theoretical value. Actual evaporation and holding time is affected by usage, atmospheric conditions, and manufacturing tolerances. ** Duration of normal operation is for reference only to estimate container performance under normal operating conditions. Actual duration may differ due to different atmospheric conditions, usage history, manufacturing tolerances, and particular circumstances. Features • 5 models from 2400 to 6000 cryovial capacity • Durable aluminium construction • High thermal efficiency • Heavy duty lockable enclosure offers excellent security • Temperature data-logging monitoring available • 5 year vacuum warranty • Compatible with all major cryobox brands • Liquid or vapour phase option available • Ultra-low evaporative Losses Trolley Holders Cryogenic Boxes 216 Diameter Lock Cap 5 ml Customized Holder 5 ml Customized Cryogenic Box 106 Liquid Nitrogen Container Accessories: Level Monitor Liquid level monitor continuously and reliably monitors the temperature inside the tank and informs users to refill LN. It is suitable for institutes that require long time cryopreservation. Three models (ZTC-100A/100B/100C) are available. The monitor offers real-time temperature display and audible/visual alarms for high temperature, sensor failure, and low liquid level. 105 Opening Diameter(MM) CO Incubator Biomedical CO Incubator Haier CO incubators are widely applied to the research and production of medicine, immunology, genetics, microbiology, agricultural science and pharmacology. The incubators are ideal equipment for experimental study of in-vitro incubation of cells, tissue, microbes, etc. Large Color Screen Display Multiple Disinfection Methods A: Microbe High-efficiency Filter Easy to Clean A high-efficiency microbe filter, which comes with a sterilization function, is installed at the CO gas inlet. Its filtration efficiency is 99.99 percent, capturing particulates with diameters equal and greater than 0.3 um. The filtration system eliminates bacteria and particulates in the CO gas to create a healthy environment for reliable experiments. Standard features include stainless steel inner liner designed with rounded corners for ease of cleaning and anti-bacteria. Space Saving Units are conveniently stackable to allow laboratory space fully utilized. B: Door Frame Heating System Protection Safety Haier CO incubator’s outer door radiates heating energy into the inner glass door to prevent condensation from occurring. The dry inner door eliminates the possibility of microbial contamination that exists in condensate water. Alarm systems feature an independent over-temperature alarm system, and a sound, illuminator system, and remote alert system that report temperature, humidity, door ajar, and malfunction conditions. The alarm systems safeguard experiments effectively. C: Automatic Control of Circulating Fan Speed The air flow inside the chamber can be automatically controlled based on the requirement of an experiment. This feature reduces the risk of drying out test samples. Specifications: Model E: Ultraviolet Sterilization System Input Power Screen Size Ultraviolet sterilization system is positioned on the rear wall inside the incubator. It is used for quickly and effectively disinfecting the inside of the incubator body to kill any floating bacteria circulating in the air and water vapor in humidifying tray. This method thereby prevents potential contamination to cell incubation. Heating Type F: Fast Recovery of Test Environment The incubator system operates with a perfect interaction of the high-precision infrared CO temperature sensor and the microcomputer controller. The result is that the CO concentration and temperature can be recovered to the set state quickly even when the doors are opened and closed frequently. The system maintains an excellent stability and uniformity of CO concentration and temperature at high usage conditions. G: Microcomputer Controller A large-screen liquid crystal display is a standard feature for ease of operation and clear display. It is controlled by a microcomputer precisely, and it can display temperature, CO concentration, and relatively humidity. H: Built-in Water Tray Design The floor of the inner door is by design an integral built-in water tray for humidification process. Pure water can be introduced directly to the water tray for a greater area of evaporation. This feature eliminates a separate water tray design which can be a source of contamination. I: Graphic Inquiry In the incubation process, all key operational parameters such as temperature, humidity, CO concentration and door usage are shown in a graphic form. Users can quickly use the information directly to analyze the incubation process. J: Door Action Actuated Control When the door is opened, operation of circulating fan, CO injection and heating system automatically stops temporally to reduce CO gas consumption, and temperature overshoot. When the door is closed, the system resumes operation automatically. 107 Control Range Operating Ambient Temperature Temperature Stability CO Control Range CO Control Accuracy CO Recovery Time Temperature Recovery Relative Humidity PYXE-80IR PYXE-150IR PYXE-240IR 500W 700W 1000W 5" LCD screen 5" LCD screen 5" LCD screen Air jacked heating system with microcomputer control Air jacked heating system with microcomputer control Ambient Temperature +5~50°C Ambient Temperature +5~50°C Air jacked heating system with microcomputer control Ambient Temperature +5~50°C +5~30°C +5~30°C +5~30°C ±0.3°C ±0.3°C ±0.3°C 0~20%V/V 0~20%V/V 0~20%V/V ±0.1% (infrared sensor) ±0.1% (infrared sensor) ±0.1% (infrared sensor) After the door is opened for 1 minute, CO concentration recovery time is less than 6 minutes. After the door is opened for 1 minute, CO concentration recovery time is less than or 6 minutes. After the door is opened for 1 minute, CO concentration recovery time is less than or 6 minutes. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. Volume Interior Dimension(WxDxH) 80L 150L 240L 400x450x500(mm) 480x530x610(mm) 600x630x670(mm) Overall Dimension(WxDxH) 590x687x790(mm) 670x767x880(mm) 788x837x940 (mm) 2/6 pieces 3/10 pieces 3/10 pieces / 3 glass door / Carrying Bracket Optional Sterilization Cycles 24hrs(90°C moist heat disinfection)24hrs(90°C moist heat disinfection) 24hrs(90°C moist heat disinfection) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization) Disinfection Method Disinfection methods include moist heat disinfection at temperature of 90°C and disinfection by ultraviole light. Users can choose one of the two methods based on specific applications. 108 CO2 Incubator D: 90°C High-temperature Moist Heat Disinfection System Moist heat disinfection at high temperature of 90°C can kill microbes and fungal spores on the inner surface of the incubator. Biomedical Table Top Low Speed Large Capacity Centrifuge Table Top Low Speed Large Capacity Centrifuge Rotor Rotor Description Capaciy Max Max Buckets AdaptersCapacity Speed RCF No. Trunnion 4×2×50ml 12×15ml 5500 5310 RPM ×g No. 1 / / / Adapter Adapter Capacity:8×15ml Capacity:8×50ml (Conical bottom) Adapter Adapter Capacity:8×50ml (Conical bottom) Capacity:8×3×5ml Fixed Angle Rotor Applicable to clinical medicine, cell culture lab, biological research, blood separation and purification. Several fixed angle rotors, horizontal rotors as well as variety of adapters available. Rotor Rotor Description Capaciy Max Max Buckets AdaptersCapacity Speed RCF No. 2×2×96 4000 2200 wells RPM ×g No. 3 / / Adapter Capacity:8×30ml Trunnion 4×2×100ml / No. 5 ELISA Plate Rotor Adapter Adapter Capacity:4×15ml Capacity:4×50ml (Conical bottom) Adapter Adapter Capacity:4×50ml (Conical bottom)Capacity:4×3×5ml LD-55T Superior performance Easy operation • Microcomputer control system with large LCD screen • Brushless variable frequency motor provides large torque, prolonged service life and avoids carbon powder pollution • A variety of rotors, buckets and adaptors available • Touch panel and digital display enable best user-friendly operations • User-adjustable centrifugal programs: parameters including speed, time, RCF and acceleration/deceleration curves are programmable 25 standard centrifugal programs to choose from Optimal effect Safety and reliability • Nine accelerating and ten braking modes (Mode 0 for unbraked run-down) • Unique noise reduction technology • Three levels of dampers to reduce vibration while optimal centrifugal effect. • Automatic cover lock • Over-speed and misoperation protection • Motor and frequency changer fault detection • Stainless steel chamber with three protective sleeves to ensure the safety No. 4 Swing-ut Rotor Capaciy: 4×100ml Max Speed : 5000 RPM Max RCF : 4390×g Max Speed Adapter Capacity:4×20ml 5310 xg Max Capacity 4x500ml Timing Range 1min~99min (LED) 30s~99min59s(LCD) Minimum Acceleration/Deceleration Time 55s/55s Speed Accuracy ± 30RPM Power Supply AC 220 ± 22V 50Hz/60Hz 10A Gross Power 1000W Noise Adapter Capacity:4×4 hematocrit tube Adapter Adapter Capacity:4×15ml Capacity:4×3×1.5ml Capacity:500ml Tube/Bottle Bucket No. 2 Adapter Capacity:8×15ml Capacity:8×3×1.5ml Adapter Capacity:10ml Adapter Capacity:7ml Adapter Capacity:5ml Bucket Capacity:4×16×5ml/7ml Bucket Capacity:4×12×5ml/7ml Adapter Capacity:4×300ml Capacity:4×3×50ml Adapter Adapter Capacity:4×100ml Capacity:4×7×20ml Adapter Adapter Capacity:4×19×5ml Adapter Capacity:4×10×15ml Swing-out Rotorc Capaciy: 4×500ml Max Speed : 4000 RPM Max RCF : 3040×g Adapter Capacity:8×4 hematocrit tube Adapter Adapter Adapter Capacity:4×10×15ml (Conical bottom) 5500RPM Max Relative Centrifugal Force(RCF) Max Speed : 4200 RPM Trunnion Max RCF : 3100×g 4×8×15ml Adapter Adapter Capacity:4×30ml Capacity:4×2×10ml LD-55T Model Capaciy: 8×100ml Adapter Capacity:8×20ml Adapter Capacity:8×2×10ml Capacity:4×9×15ml (Conical bottom) Adapter Capacity:4×28×5ml Adapter Capacity:4×4×50ml (Conical bottom) Adapter Adapter Capacity:4×20×10ml Capacity:4×4×50ml Adapter Adapter Capacity:4×25×1.5ml Capacity:4×250ml Rectangular Bucket <65dB (A) 470x550x390 (mm) Chamber Diameter Ф400 mm Net Weight 50kg 109 4×24×7ml Vacuum blood tube bucket ELISA Plate Bucket 4×2×96-well microplate 110 Lab Centrifuge Overall Size (LxWxH) Table Top High Speed Refrigerated Centrifuge Table Top High Speed Refrigerated Centrifuge LG-LG-165TD (Refrigerated) LG-165T Adapter Rotor Rotor Max Max No. Description Capaciy Speed RCF Adapters Specifi cation Applicable to radiation immunity, biochemistry, bio-pharmaceuticals, blood separation and purification. 12×1.5ml No. 1 LG-165TD Superior performance Easy operation • Touch panel and digital display enable best user-friendly operations • User-adjustable centrifugal programs: parameters including speed, time, RCF and acceleration/deceleration curves are programmable 25 standard centrifugal programs to choose from • Automatic rotor identification system • Automatic cover lock • Over-speed and misoperation protection • Motor and frequency changer fault detection • Stainless steel chamber with three protective sleeves to ensure the safety 36×1.5ml/2.2ml 12×10ml Timing Range 30s~99min59s 1min~99min -20°C ~ 40 °C - ±2.0°C - 50s/50s 35s/25s Speed Accuracy 0.5ml Adapter 0.5ml Adapter 1.5ml No. 2 Adapter 1.5ml Adapter 0.2ml 12×5ml Fixed-Angle Rotor No. 3 Adapter 13500 12835 RPM ×g 12×10ml Adapter Fixed-Angle Rotor 0.5ml 5ml 12300 15550 RPM ×g 1.5ml Adapter No. 4 Fixed-Angle Rotor 36×1.5ml /2.2ml 0.2ml No. 4 11000 10790 RPM ×g 4×10ml 6000 RPM 3200 ×g Swing-out Rotor 4×10ml Trunnion Trunnion Adapter 2×5ml 0.5ml No. 5 Swing-out ELISA Rotor 2×2×48 wells 3000 RPM 1400 ×g 2×48 wells Trunnion No. 5 48×0.5ml 12000 10920 RPM ×g Adapter / Fixed-Angle Rotor 24×1.5ml /2.2ml No. 6 Adapter 0.2ml Adapter 0.5ml Adapter / 15000 21532 RPM ×g Fixed-Angle Rotor ± 50 RPM Power Supply AC 220 ± 22V 50Hz 10A AC 220 ± 22V 50Hz/60Hz 10A Gross Power 1000W 400W Noise Net Weight Adapter 21532×g Max Capacity Chamber Diameter 0.5ml 16500 RPM Max Relative Centrifugal Force(RCF) Overall Size (L×W×H) Adapter LG-165T LG-165TD (Refrigerated) Max Speed Minimum Acceleration/Deceleration Time 0.5ml Safety and reliability • Nine accelerating and ten braking modes (Mode 0 for unbraked run-down) • Unique noise reduction technology • Three levels of dampers to reduce vibration while optimal centrifugal effect. Temperature Control Accuracy Adapter 15000 21532 RPM ×g Fixed-Angle Rotor Adapter Adapter Optimal effect Temperature Control Range 24×1.5ml /2.2ml No. 3 0.2ml 16500 18930 RPM ×g Fixed-Angle Rotor 12000 10142 RPM ×g Fixed-Angle Rotor • Microcomputer control system with large LCD screen • Brushless variable frequency motor provides large torque, prolonged service life and avoids carbon powder pollution • A variety of rotors, buckets and adaptors available • Equipped with high-efficiency CFC-free refrigeration system (Non-refrigerated model available as LG-165T) Model 12×5ml 12×1.5ml /2.2ml No. 1 Adapter Fixed-Angle Rotor No. 2 0.2ml 16500 18360 RPM ×g Rotor Rotor Max Max Adapters Adapter No. Description Capaciy Speed RCF /Buckets Specifi cation No. 6 <65dB (A) 345×590×340 (mm) 385×640×330 (mm) Ф250mm Ф280mm 70 kg 18 kg 111 Fixed-Angle Rotor 3×8×0.2ml PCR Strip 15000 13800 RPM ×g Adapter / No. 7 48×0.5ml Fixed-Angle Rotor 112 13500 13810 RPM ×g Lab Centrifuge Biomedical Water Purification System Biomedical Water Purification System Superior Performance Haier CSJM Water Purification System applies advanced technologies to provide purified laboratory water with highest quality. Depends on the requirements of your specific procedure and application, Haier CSJM Water Purification System Series Q/S/D/R can produce reverse osmosis (RO) purified water, deionized (DI) water, and ultrapure (UP) water with resistivity of 18.2 mΩ•cm at 25 °C. Haier Water Purification System is essential for your laboratory. • • • • • • High-end RO membranes and long-lasting KDF filters to ensure water quality while reducing costs Four independent ultra-purification cartridges, using nuclear grade resin to assure best quality NSF certified pure water pipes and joints Large flux (0.45 + 0.1) µm polyether compound filter terminal disinfection filter to secure sterilized Water Built-in 185 and 254 nm ultraviolet lamp to product low TOC water required by organic-sensitive applications (Optional) MWCO 5000D PES UF module to eliminate endotoxin for optimized cell cultivation and IVF (Optional) Reliability and Safety • Three-way water quality sensors provide real-time monitoring for feed water, reverse-osmosis purified water and ultrapure water • Recirculation system to keep the quality of ultrapure water when system not in use • Visual and auditory alarms on water empty and full • User-defined water quality alarm for feed water, RO purified water and ultrapure water • Automatic malfunction detection to ensure safety • Settings are password protected to avoid unauthorized operation • RS232/USB ports (Optional) for GLP compliant water quality recording Easy operation and maintenance • • • • • • • • Feed water Output water Applications ·General biochemistry experiment ·Pretreated water for ultrapure water Type II analytical grade machines,and applications (Parameters close to Type 1) with water quality requirements such as cleaning and humidifying. Basic purification LG-165T processes CSJM-Q Tap water CSJM-S CSJM-D Tap water Type I ultrapure Precision experiment PF+KDF+AC+RO+AC+DI+TF Distilled or purified water Type I ultrapure Precision experiment AC+DI+TF CSJM-R Tap water pure /ultrapure water 113 General or precision experiment,feed ultrapure water system PF+KDF+AC+RO+AC+DI PF+KDF+AC+RO+RO+AC 114 Water Purification System Series 240*128 graphical LCD display, multi-menu operating Unique on duty/off duty modes to keep the abundance of RO purified water Different sizes of tanks to meet every need and assure ample water-supply Modular structure for the convenience of cartridge maintaining and replacing One-touch operation for whole pipeline sterilization program Consumable life-span display and auto-reminding to avoid the decline of water quality Automatic RO membrane flushing procedure User-programmable water dispenser based on time and quality CSJM-Q Series Deionized Water System CSJM-S Series Ultrapure Water System Fed tap water, Haier CSJM-Q Series pure water system produces analytical-grade reverse osmosis purified and deionized water with resistivity of 16-18.2 mΩ•cm (25°C) at 15 to 30 L/min. Suitable for general chemical and biological laboratory applications. Fed tap water, conveniently produces 18.2 m Ω•cm ultrapure water at 15-30 L/min. Water quality meets or exceeds the standards of ASTM/CAP/CLSI/EP /USP Type I water. Ideal for more critical biological and analytical applications. Applications • Glassware washing • Feed ultrapure water system • Buffer and media preparation • Sample dilution and reagent preparation • Microbiological analysis • Spectrometry measurements • Water analysis and general HPLC • General Chemistry and Qualitative Analysis • Feed laboratory devices, such as autoclaves, washing machines, automatic biochemical analyzer, immunoassay analyzer, humidity chamber, salt spray chamber, aging instrument, humidifiers, and so on Specification Model Feed Water Requirements* Process Flow** CSJM-Q15 CSJM-Q15UT CSJM-Q30 CSJM-Q30UT Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2. (Additional Water softener recommend when TDS>200 ppm ) PF+KDF+AC+RO+AC+DI PF+KDF+AC+RO+AC+DI+UV+TF N/A <0.1 ppb N/A <0.1 cfu/ml Bacteria N/A <0.1 cfu/ml N/A <1/ml <1/ml Particulates (>0.2µm) Ion rejection Rate Rejection of Organic Contaminants • Molecular Biology, Microbiology • Preparation of cells and culture media • ICP-MS/AAS/GF-AAS • Electrochemical • Mammalian Cell Culture • DNA sequence analysis • PCR applications and analyses • Electrophoresis, gel analysis • Ultra-trace, trace mineral, trace organics analysis • Monoclonal Antibody Production Hybird Model CSJM-S15 CSJM-S15UF CSJM-S15UV CSJM-S15UVF High Capacity CSJM-S30 CSJM-S30UF CSJM-S30UV CSJM-S30UVF Feed Water Requirements* PF+KDF+AC+RO+ PF+KDF+AC+RO+ PF+KDF+AC+RO+ PF+KDF+AC+RO+ AC+DI+TF AC+DI+UF+TF UV+AC+DI+TF UV+AC+DI+UF+TF Resistivity 18.2 mΩ•cm (25°C) Heavy Metal Ions <0.1 ppb Total Organic Carbon <10 ppb <3 ppb <0.1 cfu/ml N/A <0.01 ng/ml N/A <0.01 ng/ml Particulates (>0.2µm) N/A <1/ml N/A <1/ml RNases N/A <0.01 ng/ml N/A <0.01 ng/ml DNases N/A <4 pg/µl N/A <4 pg/µl 30 L/h WxDxH: 500x360x540 mm, 22 kg 220V/50Hz, 120W Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories Ion Rejection Rate * Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, TF: Terminal Microfiltration *** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery 96%-99% (with new RO membranes) Rejection of Organic Contaminants >99% , when MW>200 Dalton Rejection of Particulates and Bacteria >99% Water Production Rate (25°C) *** Instant Dispensing Rate Water Outlets S15: 15 L/h, S30: 30 L/h 2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate) Two: Reverse Osmosis purified water, and Ultrapure water Dimensions WxDxH: 500x360x540 mm, 25 kg Power Supply/Power Standard System Configuration 115 Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm ) Pyrogen(Endotoxin) Two: Reverse Osmosis Purified water and Deionized water Power Supply/Power Low Levels of Organics >99% , when MW>200 Dalton 2.0 L/min (Pressure tank required) Dimensions Pyrogen-Removal 96%-99% (with new RO membranes) 15 L/h Instant Dispensing Rate Standard Normal Model Features Bacteria >99% Rejection of Particulates and Bacteria Standard System Configuration • TOC analyses, IC Process Flow** 16-18.2 mΩ•cm (25°C) Heavy Metal Ions Water Outlets • HPLC/GC-MS/ICP-AES Specification Resistivity Water Production Rate (25°C) *** Applications 220V/50Hz, 120W Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories * Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery 116 Water Purification System Biomedical CSJM-D Series Ultrapure Water System Biomedical CSJM-R Series Two Stage Reverse Osmosis Pure/ Ultrapure Water System Fed tap water, produce ultrapure water with conductivity of 1-5 µs/cm at 15-20 L/h, even if the source water is of relative poorer quality. Two-stage reverse osmosis system has with dual pumps, dual RO membranes, and a middle tank. Compared with single-stage system, two-stage RO purification system will not only produce purified water with more stable quality, but also reduce the cost of subsequent purification modules. Fed purified water, dispense up to 2 liters of 18.2 mΩ·cm Type I water per minute. Pretreated source water enables more stable ultrapure water quality, which meets or exceeds the standards of ASTM/CAP/CLSI/EP/USP Type I water. Suitable for critical laboratory applications. Applications • HPLC/GC-MS/ICP-AES • ICP-MS/AAS/GF-AAS • TOC analyses, IC Applications • Electrochemical • Molecular Biology, Microbiology • Mammalian Cell Culture • DNA sequence analysis • PCR applications and analyses • Electrophoresis, gel analysis • Preparation of cells and culture media • Glassware washing • Spectrometry measurements • DNA sequence analysis • Sample dilution and reagent preparation • Monoclonal Antibody Production • Microbiological analysis • Buffer and media preparation • Electrophoresis, gel analysis • General Chemistry and Qualitative Analysis • Ultra-trace, trace mineral, trace organics analysis • TOC analyses, IC • HPLC/GC-MS/ICP-AES • Mammalian Cell Culture • Water analysis and general HPLC • Electrochemical • Molecular Biology, Microbiology • Monoclonal Antibody Production • Preparation of cells and culture media • ICP-MS/AAS/GF-AAS • PCR applications and analyses • Ultra-trace, trace mineral, trace organics analysis • Feed laboratory devices, such as autoclaves, washing machines, automatic biochemical analyzer, immunoassay analyzer, humidity chamber, salt spray chamber, aging instrument, humidifiers, and so on Specification Model Feed Water Requirements* Process Flow** Standard Pyrogen-Removal Low Levels of Organics Hybird CSJM-D CSJM-DUF CSJM-DUV CSJM-DUVF AC+DI+TF AC+DI+UF+TF UV+AC+DI+TF Two-stage RO Ultrapurification Model CSJM-RRO CSJM-RQ CSJM-R /UF /UV /UVF Feed Water Requirements * Process Flow** <0.1 ppb Total Organic Carbon*** <10 ppb <3 ppb RO Water <0.1 cfu/ml Bacteria N/A <0.001 Eu/ml N/A <0.001 Eu/ml <1/ml Particulates (>0.2µm) RNases N/A <0.01 ng/ml N/A <0.01 ng/ml DNases N/A <4 pg/µl N/A <4 pg/µl Resistivity ≥5 mΩ•cm Water Production Rate (25°C) **** Up to 2.0 L/min Two: Deionized water, and Ultrapure water Dimensions WxDxH: 500x360x540 mm, 20 kg Power Supply/Power Standard System Configuration Two-stage RO and DI Purification UV+AC+DI+UF+TF 18.2 mΩ•cm (25°C) Heavy Metal Ions Water Outlets Two-stage RO Purificatoin Reverse Osmosis purified water, distilled water or deionized water, 5-45 °C, 1 atm Resistivity Pyrogen(Endotoxin) Model Features 220V/50Hz, 120W Water Purification Unit, accessories * Feed water affects the quality of purified water, as well as life-span of purification modules ** AC: Activated Carbon, DI: Deionization, UV: Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Depends on source water quality ****Installation of terminal microfiltration or ultrafiltration membrane will reduce the flow rate 117 Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm ) PF+KDF+AC+RO+RO+AC PF+KDF+AC+RO+RO+AC+DI+TF PF+KDF+AC+RO+RO (+UV)+AC+DI(+UF)+TF First stage RO water (TDS): Conductivity ≈ 5% source water conductivity; Second stage RO water (TDS): 1-5 µs/cm (conductivity≤% source water conductivity); Organic contaminants rejection>99% (when MW>200 Dalton); Particulates and bacteria rejection>99% DI Highly Purified Water RQ Series: Resistivity: 16-18.2 mΩ•cm, heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2µm)<1/ml Ultrapurified Water R Series: Resistivity: 18.2 mΩ•cm (25°C), heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2µm)<1/ml, TOC<10 ppb ***, (UV/UVF Series: TOC<3 ppb***) UF/UVF Series: Pyrogen<0.001 Eu/ml, RNases<0.01 ng/ml, DNases<4pg/µl 15-20 L/h Water Production Rate (25°C) **** 2.0 L/min Second Stage Instant Dispensing Rate Water Outlets Dimensions Two: Stage I, II RO water Two: Stage II RO water, DI water 220V/50Hz, 120W Power Supply/Power Standard System Configuration Two: Stage II RO water, ultrapure water WxDxH: 500x360x540 mm, about 30 kg Water Purification Unit (with one set of purification modules), Tank Set (internal water level tank ×1 + 15 L external pressure tank × 1), accessories * Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Depends on source water quality **** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery 118 Water Purification System Model Features Specification m Biomedical Models Line-up m Models Line-up F HTC-40 HTC-110 HTD-40 HTCD-90 Clean Bench light F 119 120 Haier Biomedical Models Line-up Liquid Nitrogen CO Lab Water PurificContainer Incubator Centrifuge ation System