Transcript
2016 -09
I
Biomedical
P
2016
Biomedical
Group Profile
Factories Around the World
America 3 1 2 1 12260
Europe 4 1 2 15100 Africa 4 2520
Established in 1984, Haier is the world's No. 1 major appliance brand. It has transformed from an enterprise that manufactures household appliances to a platform that incubates entrepreneurs for the whole society. In the Internet age, Haier aims to become a Networked Enterprise which overturns its self-contained enclosed system and fits into the Internet as a node that can connect various resources, with a view to building post-e-commerce ecosystems based on user value interaction for co-creation and winning together to add value for all stakeholders. On Haier's entrepreneurial platform there are two listed companies: Qingdao Haier (600690.SH) and Haier Electronics (01169.HK). The main focus of Haier Group is the innovation on three platforms: white household appliance, investment incubation and finance holding platforms. Through its exploration into the Internet Model, Haier Group has achieved steady growth. In 2015, Haier achieved a global turnover of 188.7 billion yuan with a compound growth rate of 6% over the past decade, and a total profit of 18 billion yuan with a 20% year-on-year growth rate and 30% compound growth rate over the past decade, 5 times that in revenue. The online trade volume reached 157.7 billion yuan, a year-on-year growth of nearly 200%. With the rapid development of Internet finance, the trade volume on the Internet platform totaled over 70 billion yuan. By the end of 2015, Haier's platforms have attracted over 4,700 first-rate external resources, 3 billion yuan of VC fund, 1,330 VC institutions and 103 incubators, setting the stage for 1,160 projects. Over 3,800 node microenterprises and nearly one million microstores on Haier's platforms are socializing their capital and human resources. More than 100 microenterprises boast an annual revenue of over 100 million yuan, and 22 have introduced VC, and 12 are valued at over 100 million yuan. Due to Haier’s transformation through decentralization, disintermediation and removing the “insulated wall”, the employees have decreased from the highest 110,000 to less than 60,000, but Haier's platforms have offered over 1 million jobs for the whole society. Haier's model innovation has not only been acknowledged by authoritative experts, but also verified by practical tests. In 2011, Haier announced the acquisition of Sanyo's white goods business in Japan and Southeast Asia. In 2012, Haier completed the purchase of New Zealand’s iconic home appliances company Fisher & Paykel Appliances (F&P). On January 15, 2016, Haier's globalization opened up a "historic page" - Haier signed a memorandum of strategic cooperation with GE to integrate GE's home appliances business, which set not only a new example for business cooperation between large Chinese and US enterprises, but also a new alliance model that rises above price-based trading. Haier's global brands include Haier, Casarte, Goodaymart, AQUA, Fisher & Paykel and Leader, which bring best user experience from different fields.
01
East Europe 1 2 2390 West Asia 2 2380 Medit 1 1 3 2660
South Asia 1 1 6 3560
China 42 12 3 35190 5
East Asia 3 2 1 1550
Southeast Asia 5 3 2670 1 Australia 1 610
Worldwide Network Trading Company R&D Center Manufactory Industry Park Sales Network
Overseas 19 5 24 4 45800
Global 61 8 29 16 80990
Biomedical Founded in 1998, Haier Biomedical is based in China. We design, manufacture and market laboratory equipment for the global market. Our products are designed to enable scientific researchers across the globe to perform research projects and to produce pharmaceutical products. Our products include ultra-low temperature freezers, blood banks, pharmacy refrigerators, ice-lined vaccine refrigerators, laboratory freezers, washers, fume hoods, biosafety cabinets and other types of equipment for the laboratory and medical applications. Installations can be found in blood banks, hospitals, epidemic prevention services, universities, pharmaceutical manufacturers, and national laboratories. The successful growth of our business drove a continuous development of our manufacturing ability. Along with many state of the arts manufacturing equipment, we added a new factory in 2013 to meet the increasing demand of our customers. Headquartered in Qingdao, China, our company is a part of Haier Group Company which is highly ranked as one of the key global manufacturers of durable goods. In addition to certification with ISO9001 quality system, ISO14001 environment protection system, and ISO13485:2003 quality system, the company has been awarded the People’s Republic of China Medical Device Manufacturing Enterprise License, People’s Republic of China Medical Device Registration Record, and Record of Medical Device For Medical Device Category A,B and C from the State Food and Drug Administration. Our research and development team consists of highly qualified and selective professionals specialized in refrigeration technology, control technology, remote sensing, sample protection and handling, and networking technology. Our business strategy and technological advancement have been very effective since the founding of the company. We now have shipped products to clients in over 100 countries.
02
Milestones & Awards
Premium Products
ULT Freezer
2015 In 2015,more than 3500 vaccine refrigerators have been delivered to Middle East and Africa. Haier walk-in cold room has successfully won the bidding aid to Afghanistan from WHO,aid to Philippines,Syria and Jordan from UNCIEF.
2013
2011
2009
2007
20
• World Leading Energy-efficient Haier Biomedical inaugurated a new state-of –the art manufacturing facilities for high quality production of medical cold chain products. The world most energy-saving ULT Freezer was launched by Haier Bio-Medical. 1000 units HTC-60 were delivered to Ethiopia.
Haier successfully provided MOH tender of Uzbekistan Sudan, Tanzania, Uganda and Madagascar etc., which is a new important milestone to develop the African market.
Haier won MOH tender of blood bank refrigerators and -86°C ULT freezers in Russia market.
2014
• Hrdrocarbon Refrigeration System • Reliable Sample Protection • Excellent Insulation Performance • Multi Function Alarms
2012
DW-86L728J/578J
23
ULT Freezer • LCD Touch Screen • Unique Inventory Management System
Haier won the tender "Third National HIV/AIDS Control Project (NACP - III)” from India ministry of Health and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers.
2010 Haier Medical successfully won the bid of 20,930 units vaccine refrigerator from UNOPS (United Nations Program India Purchasing Agency).
World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116.
• World Largest Capacity • Global Most Energy-efficient • Multi Function Alarms DW-86L959/729
2008 Haier Blood Transportation Box – HXC-80, won the bid of UNOPS India/NACO/BT B/35/2008, from India National AIDS Control Organization.
Biomedical Freezer
41
• Double Door Design • Double Capillary Tube • Improved Door Seal
Haier won the government procurement tender for International Assistance Program to Cuba from China.
2006 Haier became the first China based company to be certified to ISO13485:2003.
2005 Haier -150°C cryogenic freezer launched into the market – Haier medical and laboratory freezers coverd most of the temperature range required by market.
1998
• Multi Function Alarms DW-40L508/348
2004 Haier was awarded with an order from World Health Organization (WHO) and entered into the international market.
• Label Drawers
Combined Refrigerator and Freezer
49
• Refrigerator & Freezer Combination • Independent Display for Refrigerator and Freezer • Drawer with Plexiglass Dividers
The Deep Freezer(-40°C) came out, Haier entered into Medical and Laboratory Industry.
• Multi Function Alarms
HYCD-282/282A
03
04
2016 NEW PRODUCTS
Biomedical
Biomedical
Premium Products
Pharmacy Refrigerator
Premium Products
Solar Direct Drive Vaccine Refrigerator
55
• New Appearance, more intelligent
• Solar Drive,Green and Environment Friendly
• USB Data Port
• LCD Temperature Display
• Electrically Heated Glass Door
• Lockable Door Design
• Optional Printer
• Microprocessor Control
77
• Adjustable Shelves HTC-60H HYC-390/290
Under-counter Pharmacy Refrigerator
Solar Direct Drive Combined Refrigerator/Freezer
57
79
• Solar Drive,Green and Environment Friendly
• Under-counter Models
• Double Function: Storing Vaccines and Freezing Icepacks
• Electrically Heated Glass Door
• High/Low Temperature and Sensor Error Alarms
• Optimized Refrigeration System
• Lockable Door Design
• Drawers And Shelves Storage • Audible And Visible Alarm
HTCD-160 HYC-118A/118
63
Blood Bank Refrigerator
Biological Safety Cabniet
91
• EN12469 & NSF Certificated
• Consistent Cabinet Temperature 4±1°C
• Patent Intelligent Constant Air Velocity
• Microprocessor Control
• Low Noise Safety Energy-saving Mode
• Auto Defrost
• Unique Drop-down Front Glass Window
• Optional Drawers or Blood Baskets
• Patented Technology of Air Flow Recircuiation
• Multi Function Alarms HR1200-IIA2
HXC-358B
Clean Bench
75
97
• WHO/PQS Approved
• High Efficiency ULPA Filter
• Large Capacity
• UV Lamp One-key Preset
• CFC-Free
• Patented Technology of Pre-cleaning Function
• Stainless Steel Interior
• 304 Stainless Operation Platform
• Ice-packs Built In HCB-900V/HCB-1300V
HBC-340/110 05
06
2016 NEW PRODUCTS
Ice Lined Refrigerator
Preservation Cryo Freezer ULT Freezer Consumables Biomedical Freezer Combined Refrigerator and Freezer Pharmacy Refrigerator Blood Bank Refrigerator
11 13 33 39 49 53 63
WHO/PQS Certificated Vaccine & Icepack Freezer Ice-Lined Refrigerator SDD Vaccine Refrigerator Walk-In Cold/Freezer Room
73 75 77 87
Laboratory Equipment 91 97 101 107 109 113
Models Line-up Models Line-up
07
08
119
2016 NEW PRODUCTS
Biological Safety Cabinet Clean Bench Liquid Nitrogen Container CO2 Incubator Lab Centrifuge Water Purification System
Cryo Freezer & ULT Freezer 09
10
-150°C Cryo Freezer
Liquid Nitrogen Preservation System in Cryo Freezer
LN2 Freezer System(-196 °C)
DW-150W200
Model Cabinet Type
Technical Data -150°C Cryo freezer, developed by Haier Medical and Laboratory Products Co.,Ltd provides a safer, more convenient and economical alternative long term storage method than LN2 refrigeration systems. By providing a storage environment that is about 20°C colder than the water recrystallization temperature, the freezer is suitable for storage of a variety of biological samples such as virus, erythrocytes, leukocytes, cutis, skeleton, sperm, oceanic products, special test materials and even electronic products for testing. It can be installed in institutions including blood banks, hospitals, epidemic prevention services, research institutes, and research laboratories.
Chest
Climate Class
N
Cooling Type
Direct cooling
Defrost Mode
Manual
Refrigerant
Performance Control
HFC
Cooling performance(°C)
-150
Temperature Range(°C )
-126~-150
Controller
Microprocessor
Display
LED
Power Supply(V/Hz)
Temperature Control • Microprocessor control: Large LED display features a clear cabinet temperature display at an easy viewing angle and allows an adjustable range of -126°C to -150°C
Refrigeration System • • • •
Safety Control System • Alarm system: User programmable high and low temperature alarm set points, power failure, sensor error, extreme voltage, hot condenser, and extremely high ambient • Alarm types: audible buzzer and visible flashing • Protection functions: Settable pass codes for control panel, start-up delay, voltage compensation system • Properly grounded
Optimized single stage refrigeration system Hermetically sealed system Environmentally safe refrigerants Permanently lubricated fan systems
Electrical Data
Power(W)
2800
Electrical Current(A)
Functions
Accessories
11
315/385(kg) 695.0/849.5(lbs)
Interior Dimension(W*D*H)
667*462*650(mm) 26.3*18.2*25.6(in)
Exterior Dimension(W*D*H)
1670*850*1060(mm) 65.7*33.5*41.7(in)
Packing Dimension(W*D*H)
1695*940*1240(mm) 66.7*37*48.8(in)
Container load (20'/40'/40'H)
6/13/13
High/Low Temperature
Y
Remote Alarm
Y
Hot Condenser
Y
Power Failure
Y
High/Low Voltage
Y
Sensor Error
Y
Low Battery
Y N/A
High Ambient Temp
Large LED display for easy viewing Ambient range of 10 °C to 30°C LN2 back up system compatible Remote monitoring Smart condenser fans for energy saving
9 200/7.1
Net/Gross Weight(approx)
Other Features • • • • •
380/50
Capacity(L/Cu.Ft)
Dimensions
Cryo Freezer(-140°C)
Caster
Y
Foot
Y
Test Hole
Y/1
Shelves/Inner doors
-/2
12
Cryo Freezer & ULT Freezer
Biomedical
-86°C ULT Freezer
Biomedical
-86°C ULT Freezer
Operating status display
4 Individual Removable Foam Inner Doors • 4 individual inner doors can be opened independently to minimize frost buildup inside the chamber. • Unique door seal design for the minimum loss of cold temperature during a door opening. • Compatibility with existing racking system from competitors. • Stainless Steel handle to ensure the door open conveniently even in the case of frost.
Display for working temperature, setting temperature, high-alarming temperature, low-alarming temperature, password setting, and codes error
Eye-level controls for quick and easy programming and viewing
Audio/visual alarm
Excellent Doors Seals Silencing sound alarm
• 5 gasket seal , 4 seals for out door, 1 seal for inner door which provides maximum protection against thermal intrusion.
Microprocessor control panel and digital display
Malfunction detection
Adjusting key
Ambient temperature display
Selecting function
Voltage display
Alarm Triggering Condition
Alarm
Circular- chart Recorder(Optional) • Front-mounted. • For independent temperature monitoring.
DW-86L728J
Pressure Equalization Port • Heated port with spring-assisted mechanism to prevent icing on the vent. • Allows the freezer door to be opened shortly after adding samples.
High Temperature
Temperature reaches the warm alarm limit
Low Temperature
Temperature reaches the low alarm limit
Power Failure Door Ajar
Equipment loses power Door open period exceed setting time,the setting time adjustable within 0 to 20 minutes E0.Ambient sensor fails E1.Condenser sensor fails
Sensor Error
E2.Main cabinet temperature control sensor fails
Low Battery
High Efficiency Refrigeration Components • Industrial grade hermetically sealed compressors, ultra low noise under cascade cooling system. • High efficiency coalescent oil separator ensures no oil entering. • Energy efficient fan design. • Unique CH refrigeration system is optimized to provide maximum efficiency in even the most extreme ambient conditions.
13
Hot Condenser Two sample ports on back for temperature monitoring conveniently.
Battery capacity runs low or battery switch is not turned on 1. Condensers filter element is clogged 2. Ambient temperature is too high
High Ambient Temperature
Ambient temperature exceeds 32°C
14
Cryo Freezer & ULT Freezer
E3.Heat exchanger sensor fails E4.Heat exchanger temperature fails
Performance and Features
Biomedical
Heat Exchange Circulation System
Capillary Tube Capillary Tube
Safety
Installiation & Application
• Malfunction alarms including high and low temperature, power failure, sensor error, clean -filter, and extremely high ambient • Capable of producing two types of alarm outputs: audible buzzer and visible flashing light • Multiple built-in system protection features including user-settable protection code for controls, user settable delay to start, voltage compensation system, and protection against extreme high voltages • Door open feature standard and USB port for temperature data downloading standard on upright models • Remote alarm contacts • Wide range operating voltage system from 185V to 260 V designed to allow units installed in areas with poor voltage condition • Suitable for 10°C to 32°C ambient temperature • Input voltage and ambient temperature shown simultaneously for ease of monitoring environmental conditions • Robust door latch designed for secure door closing • Compact casters for ease of maneuvering
• Specialized refrigeration system design using whisper quiet fan and compressors • Freezer chassis designed to absorb vibration and sound Low sound level
• Unique door seal design for the minimum loss of cold temperature during a door opening • High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability • Patented cabinet insulation system designed for optimal performance of cold storage temperature and minimal frost buildup • Unique design of independent insulated inner door systems for independent access of storage space to provide the maximum protection of stored samples
Energy saving
Key design features
• Microprocessor-controlled system designed for controllable range of -40°C to -86°C for cabinet space with 1°C increment • Large LED display for cabinet temperature, set temperature, ambient temperature, and input voltage • Settable high temperature and low temperature alarms • Automatic clean-filter alarm and sensor error alert • Adjustable storage shelf height • Optional temperature recorder, storage racks and storage boxes 15
Evaporator
Cascade Condenser Condenser Precondenser
anti condensation
High Stage Compressor
Suction Accumlator
Pressure Switch Low Stage Compressor
Filter Dryer
Oil Separator
Filter • Filter for refrigerant to protect system from the water and other entering Capillary tube for high stage • High temperature refrigerants flow into the evaporator from the Capillary tube Capillary tube for low stage • Low temperature refrigerants flow into the evaporator from the Capillary tube High stage condenser • Extra-large air cooled condenser dissipates product heat content efficiently. Low stage Evaporator • The close contact design between the evaporating tube and the inner cabinet increases the heat conducting efficiency Ultra low noise compressor • Compressor provides reliable performance with ultra low noise • Specially designed low stage evaporator yields excellent temperature uniformity and recovery after loading and door opening. • Both high and low stage compressors are industrial grade hermetically sealed compressor designed for low temperature application. Sound level is extremely low. Heat exchanger system • Heat exchanger between the high and low temperature stage in the system Temprite oil separator • Temprite oil separator can effectively separate oil and water so as to improve the refrigeration performance
16
Cryo Freezer & ULT Freezer
Field proven reliablity
• Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber • Specialized control system design for a well-balanced operation of cascade refrigeration system • Positive field proven reliability record
Filter Dryer
CO2 Backup System
Biomedical
Advantage • • • •
LN2 Backup System
LN2 backup system is an emergency cooling device, when ULT freezer fails, LN2 backup system offers short-term protection until contents can be removed and repairs initiated. Its working principle is through controlling the solenoid valve installed in the cooling circuit, automatically injects LN2 to maintain temperature during prolonged power outage. The backup system with built-in rechargeable battery, it’ll continue to work normally when power failure.
Small footprint, light and easy for installation User adjustable temperature setting Simple to program and operate Flexible – Can be installed on any ULT freezer, which has a port hole
Safety • Liquid CO2 test button design allows end user to test the system is working • Low CO2 alarm system - alerts end user when liquid CO2 bottle is running out therefore insuring the safety of their samples
Reliability • Stainless steel covering, more elegant • Stainless steel input pipe design, allows for flexibility and ease of cylinder positioning • Durable battery lasts up to 48 hours
Technical Data Performance Control Electrical Data
Model Cabinet Type Climate Class Cooling Type Refrigerant Cooling performance(°C) Temperature Range(°C) Controller Display Power Supply(V/HZ) Power(W) Electrical Current(A) Net/Gross Weight(approx)
Dimensions
Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H)
Functions
Accessories Others
CO 2 Margin Insufficient Alarm Low Battery Alarm Sensor Error Alarm Main Power Off Alarm Charge Indicator CO 2 Injection Test Button Foot Certificate
HBX-IC HBX-IB Horizontal N Direct cooling CO 2 -70 -40~-70 Thermostat LED 208~230/60 220~240/50 115/60 20 0.25 11.2/13.6(kg) 24.7/30(lbs) 200*400*160(mm) 7.8*15.7*6.3(in) 370*530*330(mm) 14.6*20.9*13(in) Y Y Y Y Y Y 4 CE UL
Bright LED Display
Front-mounted Control Panel
“A proven solutions partner ”Marrow Donor Program(NMDP) Hundreds of -86 °C ultra low temperature freezer and the cold chain equipment monitoring and control system solution for NMDP.
Haier water-cooled ULT Freezer in SAHMRI, Australia The first water-cooled ULT freezer project of Haier biomedical in overseas market and the products were highly evaluated “Haier water-cooled ULT freezer is the best in the world!"
17
18
LN2 Backup System
Side Grille
LN2 Backup System
Biomedical
ULT Freezer
Features Linked switch design, which cuts off LN2 injection automatically when the door is opened, to ensure the safety of users. Over-charging protective circuit design, it is important for extending the service life of rechargeable battery. Portable design, light weight and easy to move, it is suitable for installation on the top of the freezer. Alarm functions, including low battery, sensor error, etc.
This product is specially designed and manufactured for long term storage of various biological products, including viruses, germs, erythrocytes, leucocytes and cutis. Applications can be found in blood banks, hospitals, epidemic prevention services, and research institutes, laboratories in electronic and chemical plants, biological engineering institutes and marine fishery companies. Haier’s next generation ULT freezer DW-86L728J is particularly designed for energy savings. It consumes the least amount of energy for the class of large ULT freezers. This new model uses environmentally safe hydrocarbon refrigerants and high efficiency fan motors to maximize the cooling ability of the system and reduce energy consumption. While providing sample safety, the new freezer design makes energy savings possible for laboratories.
Advantages Model
HBX-IIA Cabinet Type
Performance
Control
HBX-II
Horizontal
Climate Class
N
Cooling Type
Direct cooling
Refrigerant
LN 2
Cooling performance(°C)
-135
Temperature Range(°C)
-99~-135
Controller
Thermostat
Display
LED
Power Supply(V/HZ)
208~230/60 115/60
220~240/50
Electrical Data
Power(W)
20
Electrical Current(A)
0.15 15/17(kg)
Net/Gross Weight(approx) Dimensions
Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H)
Functions
Accessories Others
World leading energy-efficient Hydrocarbon refrigeration system Slim cabinet design Reliable sample protection Malfunction alarms Excellent insulation performance
33.1/37.5(lbs) 360*305*445(mm) 14.2*12.0*17.5(in) 417*357*698(mm) 16.4*14.1*27.5(in)
LN 2 Margin Insufficient Alarm
N
Low Battery Alarm
Y
Sensor Error Alarm
Y
Main Power Off Alarm
Y
Charge Indicator
Y
LN 2 Injection Test Button
N
Foot
N
Certificate
CE 19
UL 20
Cryo Freezer & ULT Freezer
Technical Data
• • • • • •
ULT Freezer
Biomedical
ULT Freezer
Extended Pull-up Time During Power Failure
Superior • Special V.I.P(Vacuum Insulation Panel) design with extra insulation factor cuts down heat loss to cabinet by 25% • High efficiency hrdrocarbon refrigerant based refrigeration system increases the efficiency by 45% than previous model • Four individual insulated inner door to keep the cold air inside • Pressure equalization port provides superior air flow making it possible to drastically reduce the stress on the freezer • Low noise 50dB(A) (reference data)
• Pull-up time measures the time taken for temperature to rise up (from -80°C to -50°C ) at 25°C ambient when the power is interrupted • Haier has the best pull-up time among the ULT freezers compared with competitors’ largest volume product
DW-86L728J Pull-up test at 25°C ambient 40 30 20 10 0
Alarms (visual and audible) Safety • Excellent temperature uniformity for an exacting sample storage requirement • High efficiency and reliability cooling fans ensure energy savings and long term storage safety
Adjustable High/Low temperature alarm Sensor error Low battery Door ajar Power failure Hot condenser High ambient Remote alarm contact
Temperature (°C)
• • • • • • • •
-10 -20 -30 -40 -60 -70 -80 -90 -100
0
Global Most Energy Efficiency
50
100 150 200 250 300 350 400 450 500 550 600 650
Time (Min)
307 (min) 220 (min) Haier Brand T DW-86L728J
184 (min) Brand N
150 (min) Brand P
Electricity charge of a 700-liter ULT Freezer Ambient Temperature
Electricity Charge (1year)
Electricity Charge (5year)
Electricity Charge (10year)
DW-86L728J
10.5*
25°C
€ 1,724.6
€ 8,623.1
€ 17,246.3
Brand P
11.5
22~26°C
€ 1,888.9
€ 9,444.4
€ 18,888.8
€90,000.0
Brand N
15.2
23°C
€ 2,496.6
€ 12,483.0
€ 24,966.0
€80,000.0
Brand T
19.0
25°C
€ 3,120.8
€ 15,603.8
€ 31,207.5
€70,000.0
Notes:*Typical data - individual units may vary and power consumption will depend on loading and operating conditions. Freezer set-point -80°C, ambient temperature 25°C, unloaded, 220~240V 50Hz power supply
€90,000.0
• Compared with Brand P, Haier DW-86L728J will help you to save €1,642.5 electricity charge in 10 years • Compared with Brand N, Haier DW-86L728J will help you to save €7,719.7 electricity charge 10 years • Compared with Brand T, Haier DW-86L728J will help you to save €13,961.2 electricity charge 10 years
€60,000.0
• The new Eco-friendly Haier ULT freezer is the most energy-efficient one in the world which is designed to help you save energy.
Average Power Consumption (Kwh/day)
€50,000.0 €40,000.0
20
€30,000.0 15
UP TO
€10,000.0
10
€0 5
(10.5)
(19.0)
(15.2)
(11.5)
Brand T
Brand N
Brand P
0 Haier
21
€20,000.0
45%
1 2 3 4 5 6 7 8 9 10 (Year) *The calculation of electricity reference to the German average industrial electricity
22
Brand T
Brand P
Brand N
Haier DW-86L728J
Cryo Freezer & ULT Freezer
Haier DW-86L728J Electricity Charge for ten years compared with other bands with similar capacity
Power Consumption (Kwh/Day)
Model
ULT Freezer
Biomedical
Haier to release the largest ultra-low temperature storage freezer with touch screen control in the global market. UNIQUE INVENTORY MANAGEMENT SYSTEM(IMS)
ULT Freezer
Two Modes Selection For customers who require the strictest tolerances, our high performance mode provides the tightest temperature uniformity. For most applications, our energy savings mode offers excellent temperature control, plus up to 13.5% savings on energy usage. • High-Performance Mode Designed with GMP applications in mind. Outstanding temperature uniformity and peak variation from setpoint • Energy-Savings Mode Excellent temperature uniformity up to 13.5% energy savings over high-performance mode 18.5
High performance
16
Energy savings
Energy Efficient
Layered display for sample storage, clear at a glance, easier to manage
16
Haier energy consumption is the lowest of all manufactures' largest capacity ULT Freezers Notes:Freezer set-point -80°C, ambient temperature 25°C, unloaded, 220~240V 50Hz power supply Haier DW-86L959
Brand T
21.8
24.6
Brand P
Average Power Consumption (KWh/day)
Extended Pull-up Time During A Power Failure • Pull-up time measures the time taken for temperatureto rise up (from -80°C to -50°C ) at 32°C ambient when the power is interrupted • Haier has the best Pull-up time among the ULT freezers compared with competitors’ largest volume product
DW-86L959
Haier DW-86L959
Brand P
40
Brand T
USB Interface
Temperature(°C)
20
Access Security Swiping Card(Optional) Message and notepad function to transmit the information conveniently
The enhanced security card control can prevent discretional opening , thus protect your sample records.
23
0 -20 -40 -60 -80 -100 0
200
400
600
800
1000
1200
260
Time(Min)
24
247
120
Cryo Freezer & ULT Freezer
Pull-up test at 32°C ambient
ULT Water Cooling
Biomedical
ULT Water Cooling
Our water cooled ULT freezers are designed to meet strict requirements for storage of plasma, biological materials, vaccines, reagents, specimens, etc. And ideal for material storage in hospitals, clinics, blood banks and medical research facilities, etc.
Model
Advantages Energy Efficiency High efficient and energy saving, reducing energy consumption under the same storage capacity by more than 20%, and cost saving Environmental Friendly Water cooled system can take away 90% exhaust heat without air conditioning, this option utilizes the cascade refrigeration design to reuse energy produced by an ultra-low freezer while delivering additional energy-savings and high performance cooling. It provides a range of benefits Intelligent control, More durable, Improved sample security, Low noise
Technical Data
Performance Control Electrical Data
DW-86L828W
DW-86L959W
Cabinet Type
Upright
Upright
Climate Class
N
N Direct cooling
Cooling Type
Direct cooling
Defrost Mode
Manual
Manual
Refrigerant
CFC-Free
CFC-Free
Noise(dB(A))
49
49
Cooling Performance(°C)
-86
-86
Temp Range(°C)
-40~-86
-40~-86
Controller
Microprocessor
Microprocessor
Display
LED
Touch Screen LCD
Power Supply(V/HZ)
220~240/50
220~240/50
Power(W)
1200
1300
Electrical Current
9
9
Capacity(L/Cu.Ft)
828/29.2
959/33.9
Net/Gross Weight(approx) Interior Dimension(W*D*H)
Dimensions Exterior Dimension(W*D*H)
The water quantity in water cooled system, can be intelligent controlled by pressure valve automatically, to make the compressor in the best operating condition and extend the usable life of freezer. High quality hermetically sealed compressor with special design, noise level lower than 50dB(A), creating a comfortable working environment It is equipped with resettable pressure protection switch design, when the water cooled system failure, the protection switch can breaker trip automatically, for protecting the refrigeration system of freezer.
50dB Functions
Refrigeration system High efficient and energy saving, reducing energy consumption under the same storage capacity by more than 20%, and cost saving The water cooled condenser option can take away 90% the heat generated in the process of refrigeration to the outdoor without air conditioning, making the laboratory environment more comfortable.
Accessories
Others 25
380/410
450/485
837.8/903.9
992.1/1069.2
(mm)
870*716*1310
1016*716*1310
(in)
34.3*28.2*51.6
40.4*28.2*51.6
(mm)
1145*980*1980
1296*998*1980
(in)
45.1*38.6*78.0
51.0*39.3*78.0
(mm)
1190*1045*2150
1365*1105*2150
(in)
46.9*41.1*84.6
53.7*43.5*84.6
Container load(20'/40'/40'H)
8/20/20
8/16/16
High/Low Temp
Y
Y
Hot Condenser
Y
Y
Power Failure
Y
Y
High/Low Voltage
N/A
Y
Sensor Error
Y
Y
Low Battery
Y
Y
High Ambient Temp
Y
Y
Door Ajar
Y
Y
Caster
Y
Y
Foot
Y
Y
Packing Dimension(W*D*H)
Ergonomic Design
(kg) (lbs)
Test Hole
Y/1
Y/2
Shelves/Inner doors
3/4
3/4 Y
USB Interface
Y
Remote Alarm
Y
Y
Temp Recorder
Optional
Optional
Rs232/485 Interface
Optional
Optional
CO2 Backup System
Optional
Optional
LN2 Backup System
Optional
Optional
Certificate
CE
CE
26
ULT Water Cooling
Specification
-86°C ULT Freezer
Biomedical
-86°C ULT Freezer
Specification
Technical Data
DW-86L338J
DW-86L388A
DW-86L388J
DW-86L486
DW-86L490J
DW-86L578
DW-86L578J
Upright
Upright
Upright
Upright
Upright
Upright
Upright
Upright
DW-86L628 Upright
Climate Class
N
N
N
N
N
N
N
N
N
N
Cooling Type
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Defrost Mode
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
HC
HFC
HC
HFC
HC
HFC
HFC
50
49
50
-86
-86
HFC
Refrigerant
Control
Cooling Performance(°C) Temp Range(°C) Controller Display
Others
50
50
-86
-86
-86
-86
-86
-86
-86
-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
Microprocessor
Microprocessor
Microprocessor
LED
LED
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
LED
LED
LED
LED
LED
LED
LED
115/60
220~240/50
220~240/50
220~240/50
220~240/50 208~230/60 115/60
LED
220~240/50
208~230/60
208~230/60
115/60
220~240/50
220~240/50 208~230/60 115/60 220~240/50 208~230/60 115/60
900
1000
1200
900
1000
1000
1000
1000
1200
900
1000
1000
1000
900
1200
1200
1200
1200
1200
1200
7.5
8
18
7.5
8
8
9
5.5
18
8
8
9
18
9
7
9
18
9
9
18
338/11.9
388/13.7
388/13.7
338/11.9
486/17.1
490/17.3
578/20.4
578/20.4
628/22.2
728/25.7
(kg)
238/278
238/278
255/286
255/286
290/310
295/335
300/330
300/330
301/323
345/385
(lbs)
524.7/612.9
524.7/612.9
562.2/630.5
562.2/630.5
639.3/683.4
650.4/738.5
661.4/727.5
661.4/727.5
663.6/712.1
760.6/848.8
Interior Dimension (W*D*H)
(mm)
465*630*1165
465*630*1165
465*630*1310
465*630*1310
590*630*1310
590*630*1310
620*716*1310
620*716*1310
760*630*1310
766*716*1310
(in)
18.3*24.8*45.9
18.3*24.8*45.9
18.3*24.8*51.6
18.3*24.8*51.6
23.3*24.8*51.6
23.3*24.8*51.6
24.4*28.2*51.6
24.4*28.2*51.6
29.9*24.8*51.6
27.0*28.2*51.6
Exterior Dimension (W*D*H)
(mm)
812*893*1846
812*893*1846
812*893*1980
812*893*1980
945*900*1980
860*900*1980
895*980*1980
895*980*1960
1035*900*1980
1041*980*1980
(in)
32.0*35.2*72.7
32.0*35.2*72.7
32.0*35.2*78.0
32.0*35.2*78.0
37.2*35.4*78.0
33.9*35.4*78.0
35.4*38.6*78.0
35.4*38.6*78.0
40.7*35.4*78.0
36.7*38.6*78.0
Packing Dimension (W*D*H)
(mm)
875*970*2010
875*970*2010
875*970*2135
875*970*2135
995*995*2150
925*985*2150
1055*950*2150
1055*950*2125
1080*965*2150
1090*1050*2150
(in)
34.5*38.2*79
34.5*38.2*79
34.5*38.2*84.1
34.5*38.2*84.1
39.2*39.2*84.6
36.4*38.5*84.6
41.5*37.4*84.6
41.5*37.4*83.7
42.5*38*84.6
43*41.3*84.6
12/24/24
12/24/24
12/24/24
12/24/24
12/24/24
12/24/24
12/24/24
12/24/24
12/24/24
12/20/20
High/Low Temp
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Hot Condenser
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Power Failure
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Sensor Error
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Low Battery
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
High Ambient Temp
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Door Ajar
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Caster
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Foot
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Test Hole
Y/1
Y/2
Y/1
Y/2
Y/1
Y/2
Y/2
Y/2
Y/1
Y/2
Shelves/Inner doors
Container load(20'/40'/40'H)
Accessories
49
50
Electrical Current
Net/Gross Weight (approx)
Functions
50
Power(W) Capacity(L/Cu.Ft)
Dimensions
50
HFC
Upright
-40~-86
220~240/50 208~230/60
Power Supply(V/HZ) Electrical Data
HC
50
Noise(dB(A)) Performance
DW-86L728
DW-86L338
High/Low Voltage
3/2
3/2
3/2
3/2
3/4
3/4
3/4
3/4
3/4
3/4
USB Interface
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Remote Alarm
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
Y
N/A
Y
Y
Y
Y
Y
Y
Y
Temp Recorder
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Rs232/485 Interface
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
CO2 Backup System
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
LN2 Backup System
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
CE,UL
CE
CE
CE
CE,UL
UL
CE
CE,UL
CE,UL
5Vpower supply module
Certificate
CE
/
Product appearance and specifications are subject to change without notice
27
28
Cryo Freezer & ULT Freezer
Model Cabinet Type
Technical Data
Performance Control
DW-86W420
DW-86W420J
Chest
Chest
Chest
Chest
N
N
N
N
N
N
N
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Direct cooling
Climate Class
N
N
Cooling Type
Direct cooling
Defrost Mode
DW-86W100
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Refrigerant
HC
HFC
HFC
HC
HFC
HFC
HC
HFC
HC
Noise(dB(A))
50
49
49
50
49
49
49
50
49
Cooling Performance(°C)
-86
-86
-86
-86
-86
-86
-86
-86
-86
Temp Range(°C) Controller Display Power(W)
(kg)
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
-40~-86
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
LED
Touch Screen LCD
LED
LED
Touch Screen LCD
LED
LED
LED
220~240/50
220~240/50 208~230/60
220~240/50 208~230/60
220~240/50
220~240/50
220~240/50/60
115/60
220~240/50
220~240/50
220~240/50 208~230/60
1200
1000
1300
650
650
550
1000
1000
9
10
9
4
7.5
7.5
959/33.9
100/3.5
100/3.5
420/14.8
450/485
138/160
138/160
310/357
310/357
1000
1200
1200
1200
10
8
9
9
728/25.7
729/25.7
828/29.2
828/29.2
345/385
350/385
380/410
380/410
LED
7.5
12
1000 7.5 420/14.8
(lbs)
760.6/848.8
772.3/848.8
837.8/903.9
837.8/903.9
992.1/1069.2
304.2/352.7
304.2/352.7
683.4/787.1
683.4/787.1
Interior Dimension (W*D*H)
(mm)
766*716*1310
766*716*1310
870*716*1310
870*716*1310
1016*716*1310
470*450*480
470*450*480
1367*462*652
1367*462*652
(in)
27.0*28.2*51.6
27.0*28.2*51.6
34.3*28.2*51.6
34.3*28.2*51.6
40.4*28.2*51.6
18.5*17.7*18.9
18.5*17.7*18.9
53.8*18.2*25.7
53.8*18.2*25.7
Exterior Dimension (W*D*H)
(mm)
1041*980*1980
1046*998*1980
1145*980*1980
1145*980*1980
1296*998*1980
769*825*1120
769*825*1120
2130*870*1020
2130*870*1020
(in)
36.7*38.6*78.0
41.2*39.3*78.0
45.1*38.6*78.0
45.1*38.6*78.0
51.0*39.3*78.0
30.34*32.5*44.1
30.34*32.5*44.1
83.9*34.3*40.2
83.9*34.3*40.2
Packing Dimension (W*D*H)
(mm)
1090*1050*2150
1100*1095*2150
1190*1045*2150
1190*1045*2150
1365*1105*2150
845*855*1250
845*855*1250
2195*895*1130
2195*895*1130
(in)
43*41.3*84.6
43.3*43.1*84.6
46.9*41.1*84.6
46.9*41.1*84.6
53.7*43.5*84.3
33.3*33.7*49.2
32.9*33.9*48.6
86.4*35.2*44.5
90.6*38.2*45.8
12/20/20
10/20/20
8/20/20
8/20/20
8/16/84.6
12/24/48
12/24/48
6/12/24
6/12/24
High/Low Temp
Y
Y
Y
Y
Y
Y
Y
Y
Y
Hot Condenser
Y
Y
Y
Y
Y
Y
Y
Y
Y
Power Failure
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
Y
N/A
N/A
Y
Y
N/A
Y
N/A
Sensor Error
Y
Y
Y
Y
Y
Y
Y
Y
Y
Low Battery
Y
Y
Y
Y
Y
Y
Y
Y
Y
High Ambient Temp
Y
Y
Y
Y
Y
Y
Y
Y
Y
Door Ajar
Y
Y
Y
Y
Y
N/A
Y
N/A
Y
Caster
Y
Y
Y
Y
Y
Y
Y
Y
Y
Container load(20'/40'/40'H)
High/Low Voltage
Y
Y
Y
Y
Y
Y
Y
Y
Y
Test Hole
Y/2
Y/2
Y/1
Y/2
Y/2
Y/1
Y/1
Y/1
Y/1
Shelves/Inner doors
Foot
Others
DW-86W100J
Upright
Upright
Net/Gross Weight (approx)
Accessories
DW-86L959
Upright
Upright
Capacity(L/Cu.Ft)
Functions
DW-86L828J
Upright
DW-86L728J
Electrical Current
Dimensions
DW-86L828
DW-86L729
Model Cabinet Type
Power Supply(V/HZ) Electrical Data
-86°C ULT Freezer
3/4
3/4
3/4
3/4
3/4
-/1
-/1
-/3
-/3
USB Interface
Y
Y
Y
Y
Y
N/A
Y
N/A
Y
Remote Alarm
Y
Y
Y
Y
Y
Y
Y
Y
Y
5Vpower supply module
Y
Y
Y
Y
Y
N/A
N/A
N/A
N/A
Temp Recorder
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Rs232/485 Interface
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
CO2 Backup System
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
LN2 Backup System
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
CE
CE,UL
CE,UL
CE
CE
CE,UL
CE
CE,UL
CE、UL
Certificate
Product appearance and specifications are subject to change without notice
29
30
Cryo Freezer & ULT Freezer
-86°C ULT Freezer
Biomedical
Consumables for ULT Freezer
31
32
PC Freezer Boxes
PP Freezer Boxes
Biomedical
F FEATURES ■
■
■
■
Made of Polycarbonate(PC) Sturdy and durable Temperature range: stable from -196ºC to 121ºC Suitable for liquid nitrogen storage
Features
■
3
4
5
6
7
8
9 10
A
41 42 43 44 45 46 47 48 49 50
A
Boxes are designed with international standard size, which can f it all of the standard cryogenic vials and freezer racks
51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
O
O
81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100
Store in mechanical freezers Boxes are vented, allowing rapid cooling of contents and full drainage
B
C D E
B
C
F
Made of polypropylene for use with temperature from -80ºC to 121ºC
G
HBB-281-PC
B
Chemically resistant to alcohols and mild organic solvents
HBB-200-C
Dimensions: 133 x 133 x 53.5mm
F
■
2
11 12 13 14 15 16 17 18 19 20
31 32 33 34 35 36 37 38 39 40
C
■
O
21 22 23 24 25 26 27 28 29 30
E
■
1
O
C
■
For easy inventory management of cryogenic vials used in tissue culture, pharmaceutical research and other biotechnology labs
D
■
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
1
2
3
4
5
6
7
8
9 10
Ordering Information
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Box Design
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
81 82 83 84 85 86 87 88 89 90
73
74
75
76
77
78
79
80
81
91 92 93 94 95 96 97 98 99 100
A
A
G
Cat#
Well
Material
Color
Height
PC
Assorted Colors(Red, Greenmixed)
2inch
Dimensions
Unit
■
51 52 53 54 55 56 57 58 59 60
B
T130
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
HBB-281-PC 81-well
HBB-200-PP
133*133*53.5(mm) 50 sets/case 5.2*5.2*2.2(in)
■
■
Dimensions: T130 : 133 x 133 x 53.5mm HBB-200-PP : 133 x 133 x 53.5mm
HBB-200-C 100-well
PC
Box Design
Assorted Colors(Red, Yellow, Blue, Green mixed)
2inch
133*133*53.5(mm) 5.2*5.2*2.2(in)
4 colors/bag, 4 bags/box, 24sets/case
■
■
■ ■
9x9 well storage (81-well total) or 10x10 well storage (100-well total)
■
Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials
■
HBB-200-PP box with numeric identification on each column for quick
9x9 well storage (81-well total) or 10x10 well storage (100-well total) Boxes are designed with international standard size, which can fit all of the standard cryogenic vials and freezer racks With 4 assorted colors: red, yellow, green, and blue for better color-coding Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials 81-well box features a removable lid includes a numbered grid for orientation 100-well box with numeric identification on each column for quick sample identification
sample identification
Ordering Information Cat#
Well
Material
Sterile
Unit
T130
81-well
PP
No
50sets/ case
HBB-200-PP
100-well
PP
No
50sets/ case
33
Easy for sample organization
Each box includes drain holes and air vents in the lid and bottom to minimize condensation
34
Cryogenic Supplies
Numbered grid for orientation
Consumables For ULT Freezer ULT Model
DW-86L338 /338J
FEATURES ■
■
■
■
■
■
■
Sliding drawer and side access type design for choose. Fully functional Freezer Rack is constructed of corrosion-resistant stainless steel Sliding Drawer Freezer Racks include handles for easy removal off the shelf Optimize Freezer Storage Space Ideal for storage of 2” standard size boxes Fits most standard upright freezers Available with Sliding Drawer, Frame Type and Vertical Type Freezer Racks
Racks Model DCJ-54-A(2014) DCJ-54-B(2014) (the 2nd and the 3rd layer) DCJ-44-A(2014) DCJ-44-B(2014) (the 1st and the 4th layer)
DW-86L388A DCJ-54-A(2014) /388J DCJ-54-B(2014)
DCJ-54-A(2014) DW-86L486 DCJ-54-B(2014)
DCJ-54-A(2014) DCJ-54-B(2014) (the 1st and the 2nd layer) DW-86L490 /490J DCJ-44-A(2014) DCJ-44-B(2014) (the 3rd and the 4th layer)
DW-86L578 DCJ-55-A(2014) DCJ-55-B(2014) /578J
DW-86L628 DCJ-54-A(2014) DCJ-54-B(2014)
DW-86L728 DCJ-55-A(2014) /728J DCJ-55-B(2014)
DW-86L729 DCJ-55-A(2014) DCJ-55-B(2014)
Parameters Product
DW-86L828 DCJ-55-A(2014) DCJ-55-B(2014) /828J
Model DCJ-44-A(2014) DCJ-44-B(2014) DCJ-54-A(2014)
2 inch stainless stell rack
DCJ-54-B(2014) DCJ-55-A(2014) DCJ-55-B(2014) DCJ-08-A(2014) DCJ-10-A(2014)
Rack Description
Rack Dimension(W*D*H)
2 inch stainless steel rack 4*4 (2 inch box *16) 2 inch stainless steel drawer rack 4*4 (2 inch box *16) 2 inch stainless steel rack 5*4 (2 inch box *20) 2 inch stainless steel drawer rack 5*4 (2 inch box *20) 2 inch stainless steel rack 5*5 (2 inch box *25) 2 inch stainless steel drawer rack 5*5 (2 inch box *25) 2 inch stainless steel rack 8*1 (2 inch box *8) 2 inch stainless steel rack 10*1 (2 inch box *10)
"138*565*24(mm) 5.4*21.4*9.2(in)" "140*565*24(mm) 5.5*21.8*9.3(in)" "138*565*293(mm) 5.4*21.4*11.3(in)" "140*565*293(mm) 5.5*21.8*11.4(in)" "138*685*293(mm) 5.4*26.8*11.3(in)" "140*685*293(mm) 5.5*27.1*11.4(in)" "140*140*480(mm) 5.4*5.6*18.1(in)" "140*140*600(mm) 5.4*5.6*24.9(in)"
35
Boxes Q'ty/layer
3
3
3
4
4
4
4
5
5
5
6
ULT Freezer Models DW-86L338/338J/490/490J
DW-86L338/388A/486/490/628
DW-86L578/728/828/578J/ 728J/828J/729/959
DCJ-55-A(2014) DW-86L959 DCJ-55-B(2014)
DW-86W100 DCJ-08-A(2014)
DW-86W420 DCJ-10-A(2014)
7
9
27
DW-86W100 DW-150W200 DCJ-10-A(2014)
DW-86W420/DW-150W200
12
Vials
Total Q'ty For ULT Freezer
Material
Model
Q'ty/ Rack
Model
Q'ty/Box
Q'ty/Rack
PP
T130
20
1.0/1.5/2.0ml
81
1620
Racks
Boxes
Vials
120
9720
120
12000
PP
HBB-200-PP
20
1.0/1.5/2.0ml
100
2000
PC
HBB-281-PC
20
1.0/1.5/2.0ml
81
1620
PC
HBB-200-C
20
1.0/1.5/2.0ml
100
PP
T130
16
1.0/1.5/2.0ml
PP
HBB-200-PP
16
1.0/1.5/2.0ml
PC
HBB-281-PC
16
1.0/1.5/2.0ml
81
1296
PC
HBB-200-C
16
1.0/1.5/2.0ml
100
1600
96
9600
PP
T130
20
1.0/1.5/2.0ml
81
1620
240
19440
240
24000
240
19440
6
120
9720
2000
120
12000
81
1296
96
7776
100
1600
96
9600
96
7776
6
PP
HBB-200-PP
20
1.0/1.5/2.0ml
100
2000
PC
HBB-281-PC
20
1.0/1.5/2.0ml
81
1620
PC
HBB-200-C
20
1.0/1.5/2.0ml
100
2000
240
24000
PP
T130
20
1.0/1.5/2.0ml
81
1620
320
25920
PP
HBB-200-PP
20
1.0/1.5/2.0ml
100
2000
320
32000
PC
HBB-281-PC
20
1.0/1.5/2.0ml
81
1620
320
25920
PC
HBB-200-C
20
1.0/1.5/2.0ml
100
2000
320
32000
PP
T130
20
1.0/1.5/2.0ml
81
1620
160
12960
PP
HBB-200-PP
20
1.0/1.5/2.0ml
100
2000
160
16000
PC
HBB-281-PC
20
1.0/1.5/2.0ml
81
1620
160
12960
PC
HBB-200-C
20
1.0/1.5/2.0ml
100
2000
160
16000
PP
T130
16
1.0/1.5/2.0ml
81
1296
128
10368
PP
HBB-200-PP
16
1.0/1.5/2.0ml
100
1600
128
12800
PC
HBB-281-PC
16
1.0/1.5/2.0ml
81
1296
128
10368
PC
HBB-200-C
16
100
1600
128
12800
PP
T130
25
1.0/1.5/2.0ml 1.0/1.5/2.0ml
81
2025
400
32400
PP
HBB-200-PP
25
1.0/1.5/2.0ml
100
2500
400
40000
PC
HBB-281-PC
25
1.0/1.5/2.0ml
81
2025
400
32400
PC
HBB-200-C
25
1.0/1.5/2.0ml
100
2500
400
40000
PP
T130
20
1.0/1.5/2.0ml
81
1620
400
32400
PP
HBB-200-PP
20
1.0/1.5/2.0ml
100
2000
400
40000
PC
HBB-281-PC
20
1.0/1.5/2.0ml
81
1620
400
32400
PC
HBB-200-C
20
1.0/1.5/2.0ml
100
2000
400
40000
PP
T130
25
1.0/1.5/2.0ml
81
2025
500
40500
PP
HBB-200-PP
25
1.0/1.5/2.0ml
100
2500
500
50000
PC
HBB-281-PC
25
1.0/1.5/2.0ml
81
2025
500
40500
PC
HBB-200-C
25
1.0/1.5/2.0ml
100
2500
500
50000
PP
T130
25
1.0/1.5/2.0ml
81
2025
500
40500
PP
HBB-200-PP
25
1.0/1.5/2.0ml
100
2500
500
50000
PC
HBB-281-PC
25
1.0/1.5/2.0ml
81
2025
500
40500
PC
HBB-200-C
25
1.0/1.5/2.0ml
100
2500
500
50000
PP
T130
25
1.0/1.5/2.0ml
81
2025
600
48600
PP
HBB-200-PP
25
1.0/1.5/2.0ml
100
2500
600
60000
PC
HBB-281-PC
25
1.0/1.5/2.0ml
81
2025
600
48600
PC
HBB-200-C
25
1.0/1.5/2.0ml
100
2500
600
60000
PP
T130
25
1.0/1.5/2.0ml
81
2025
700
56700
PP
HBB-200-PP
25
1.0/1.5/2.0ml
100
2500
700
70000
PC
HBB-281-PC
25
1.0/1.5/2.0ml
81
2025
700
56700
PC
HBB-200-C
25
1.0/1.5/2.0ml
100
2500
700
70000
PP
T130
8
1.0/1.5/2.0ml
81
648
72
5832
PP
HBB-200-PP
8
1.0/1.5/2.0ml
100
800
72
7200
PC
HBB-281-PC
8
1.0/1.5/2.0ml
81
648
72
5832
PC
HBB-200-C
8
1.0/1.5/2.0ml
100
800
72
7200
PP
T130
10
1.0/1.5/2.0ml
81
810
270
21870
270
27000
270
21870 27000
12
16
8
8
16
20
20
20
24
28
9
PP
HBB-200-PP
10
1.0/1.5/2.0ml
100
1000
PC
HBB-281-PC
10
1.0/1.5/2.0ml
81
810
PC
HBB-200-C
10
1.0/1.5/2.0ml
100
1000
270
PP
T130
10
1.0/1.5/2.0ml
81
810
120
9720
PP
HBB-200-PP
10
1.0/1.5/2.0ml
100
1000
120
12000
PC
HBB-281-PC
10
1.0/1.5/2.0ml
81
810
PC
HBB-200-C
10
1.0/1.5/2.0ml
100
1000
36
27
12
120
9720
120
12000
Cryogenic Supplies
Stainless Steel Freezer Racks
Biomedical
Biomedical Freezer
37
38
-40°C Biomedical Freezer (Upright)
Biomedical
-40°C Biomedical Freezer (Upright)
Safety
This product is design for storage of critical and temperature sensitive biological samples, medical products, and so on in institutions such as blood banks, hospitals, etc.
Alarm system, including high temperature, sensor error, power failure, door ajar, low battery, high ambient temperature, etc The audio-visual alarms, and remote alarm contacts
Key Features
Backup battery for continuously monitoring and displaying the interior temperature over 48hs after power failure
Forced air and frost-free design: Storage at -40°C with automatic defrost, Non-invasive defrost with time and temperature guided cycle, ensure temperature stability and minimize energy use
The USB port are standard, the temp data can be recorded on chart paper or loaded in flash disc, maximum data safety
Intelligent operation and control at -40°C and forced air circulation for uniform temperature and high-performance refrigeration
Lockable door with Padlock for added sample security
Microprocessor controls with digital display with 0.1°C increment, and adjustable temperature range: -20~-40°C
Ergonomic Design Self closing door with 90°stay-open feature, energy-conserving, maintains temperature uniformity to protect your valuable samples Interior brushed stainless steel liner and Exterior coated steel plate, corrosion free 5 adjustable stainless steel shelves and drawers with partition to separately store varied plasma bags Backup battery protection
USB
Malfunction Alarms
Casters and leveling leg, easy to move and lock
DW-40L420F
Pull down test at 25°C ambient
Temperature Uniformity -35 -36
Temperature (°C)
Temperature (°C)
30 25 20 10 0 -10 -20 -30 -40 -50
Drawer
Microprocessor control panel
Air distribution
-38 -39 -40 -41 -42 -43 -44 -45
10
35
60
85
110
135
160
185
210
235
260
285
310
335
360
0
Time (min)
25
50
75
100
125
150
175
200
225
250
275
Time (min) *Freezer set-point -40 °C,ambient temperature 25 °C
Product appearance and specifications are subject to change without notice
39
-37
40
Biomedical Freezer
Padlock
-40°C Biomedical Freezer(Double Doors Type)
Biomedical
The -40°C deep freezer offers a large capacity storage space with fast temperature performance. Integrated design of cold shelf and evaporator provides additional refrigeration efficiency. This product is designed to store vaccines, blood plasma, and many other biological materials. Installations can be found in research institutions and clinical sites in life science, electronic testing and medical markets.
-40°C Biomedical Freezer(Double Doors Type)
Haier ‘s next generation low temperature storage freezer, DW-40L348, is designed based on the original work horse platform of DW-40L508. The new freezer model operates with two capillary tubes and is equipped with dual gaskets to improve the temperature uniformity through the chamber drastically. It can be installed to satisfy tougher application requirements in universities, research institutions and blood banks.
Reliability and Key Features • Rated for -40°C at 32 °C ambient • Rapid cooling with shelf evaporator • Improved temperature uniformity with dual capillary tube design at the range of -20 °C to -40°C • Improved door seal design with two gaskets maintains cabinet temperature more efficiently • Frost buildup is reduced • Insulation thickness is 90 mm for additional robustness, less power consumption and more temperature retaining ability • Drawer design maximizes storage space. One unit can hold 360 bags of 230 ml blood bags
Safety • Multiple malfunction alarms include high/low temperature, power failure, sensor error, low battery, high/low ambient temperature • Two types of alarms: buzzer and flashing light
DW-40L508
DW-40L348 Ergonomic Design
Control panel
Drawer
Shelf 41
Biomedical Freezer
• LED digital display for clear observation • Double door design with independent locks reduces air leakage to ensure temperature stability and lower power consumption • Tracks to label drawers for product identification
Handle 42
-40°C Biomedical Freezer (Upright)
Biomedical
-40°C Biomedical Freezer (Chest)
Key Features
Reliability and Key Features
Microprocessor control, adjustable temperature range :-20°C to -40°C LED digital display and increment at 0.1°C Permanently lubricated cooling fan for safety and longevity Rapid cooling with shelf evaporator Removable double outer door seal design, good sealing effect and energy saving
• High efficiency low temperature compressor with known field reliability • Chemically stable, CFC-free, commercially available and environmentally safe refrigerant • Permanently lubricated cooling fan for safety and longevity , high density insulation foam for stable and long term storage temperature • Optimized refrigeration system designed to maximize cooling effect and temperature uniformity • Microprocessor control, digital display, adjustable temperature range: -20°C~-40°C • LED digital display for clear observation • Wide voltage tolerance design with applicable voltage range of 198~252 V/AC
Ergonomic Design USB data logging and temperature recorder (optional) Padlock with stainless steel cylinder for safe storage Drawers are designed with label holders for item identification
Safety • Multiple malfunction alarms to detect high / low temperature, sensor error and power failure • Two types of alarm indications: audible buzzing and visual flashing light
Safety Multiple malfunction alarms include high/low temperature, sensor error, power failure, high ambient temperature, low battery Alarm Types: buzzer, flashing light, remote alarm
Ergonomic Design
Electronic Thermostat
Inner
Temperature (°C)
DW-40W380 Pull-up test at 32°C ambient
Temperature (°C)
DW-40W380 Pull down test at 32°C ambient
seal
USB data logging(optional)
0
0.25 0.5 0.75
1
1.25 1.5 1.75
2 2.25 2.5 2.75
3
3.25 3.5
0
Time (H)
43
0.5
1
1.5
2
2.5
3
3.5
4
4.5
Time (H)
44
5
5.5
6
6.5
7
7.5
Biomedical Freezer
DW-40L278
• Door lock for storage safety • Standard ø40 access port for testing instrumentation except model DW-40W380 • Corrosion proof cabinet interior design • Suitable for a variety of storage baskets
Model
Technical Data
Performan ce Control Electrical Data
835*895*2020(mm) 32.9*35.2*79.5(in)
DW-40L420F Upright SN,N Forced air cooling / CFC-Free 45dB -40 -20~-40 Microprocessor LED 220~240/50HZ 900 4.5A 420L 195/225(kg) 429.9/496.0(lbs) 685*610*1028mm 27.0*24.0*40.5(in) 950*890*1900mm 37.4*74.4*74.8(in) 980*905*2040mm 38.6*36.0*80.3(in)
24/48/48
14/28/28
12/24/24
12/24/24
Y
Y
Y
Y
Y
Y
Power Failu re High/Low Voltage
N/A N/A N/A
Y Y N/A
Y Y N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Sensor Error w Battery High Ambient Temp
Y
Y
N/A N/A
N/A N/A
Y Y
Y Y
Y Y
Y Y Y
N/A 3/N/A N/A
Y 7/N/A N/A
Y 12/Optional Optional
Y Y Y Y Y Y Y Y Y Y Y Y Optional CE
Y
N/A N/A N/A
Cabinet Type Climate Class ooling Type efrost Mode efrigerant Noise(dB(A)) ooling Per formance(°C) emperature Range(°C) ontroller Display ower Supply(V/Hz) ower(W) Electrical Current(A) Capaci ty(L/Cu.Ft) Net/Gross Weight (approx)
Dimensions
Interior Dimension (W*D*H) Exterior Dimension (W*D*H) Packing Dimension (W*D*H) Container Load (20'/40'/40'H) High/Low Temperature Remote Alarm
Functions
-40°C Biomedical Freezer
Accessories
Caster ot est Hole Drawers/Inner Doors USB Interface Temperature Recorder
Others
Certificate
DW-40L92 Upright N Direct cooling Manual CFC-Free
DW-40L262 Upright N Direct cooling Manual CFC-Free
Upright, double door N Direct cooling Manual CFC-Free
40 -40 -20~-40 Microprocessor LED
44 -40 -20~-40 Microprocessor LED
45 -40 -20~-40 Microprocessor LED
220~240/50 200 0.5 92/3.3
220~240/50 115/60 340 600 3.9 7.5 262/9.3
220~240/50 360 2.9 348/12.3
46/51(kg)
88/88(kg)
137/145(kg)
101.4/112.4(lbs) 465*440*645(mm)
194.0/194.0(lbs) 480*465*1430(mm)
302.0/319.7(lbs) 535*610*1228(mm)
18.3*17.3*25.4(in) 597*610*860(mm)
18.9*18.3*56.3(in) 657*685*1665(mm) 745*675*
21.1*24.0*48.3(in) 765*810*1860(mm)
23.5*24.0*33.9(in) 660*700*935(mm) 26*27.6*36.8(in)
25.9*27.0*65.6(in)
DW-40L348
3.1
29.3*26.6*
775*760*1755(mm) 805*725*1970(mm) 30.5*30*69(in) 31.7*28.5*77.6(in)
54/108/108
CE
CE
/
30.1*32.0*73.2(in)
CE
DW-40L508 Upright, double door N Direct cooling Manual CFC-Free 45 -40 -20~-40 Microprocessor LED 220~240/50 430 2.9
208~230/60 430 2.9
DW-40W100 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 255 5.0
115/60 255 5.0
DW-40W255 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 410 4.2
DW-40W380 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 550 5.1
208~230/60 550 5.1
490/17.3 164/200(kg)
100/3.5 43/46(kg)
255/9.0 70/82(kg)
380/13.4 82/89(kg)
360.8/440.9(lbs) 685*610*1228(mm)
94.8/101.4(lbs) 500*385*625(mm)
154/180.8(lbs) 1040*430*605(mm)
180.8/196.2(lbs) 1376*457*625(mm)
27.0*24*48.3(in) 915*810*1860(mm) 36.0*71.3*73.2(in)
19.7*15.2*24.6(in) 680*600*805(mm) 26.8*23.6*31.7(in)
40.9*16.9*23.8(in) 1243*633*838(mm) 48.9*24.9*33.0(in)
54.2*18.0*24.6(in) 1550*633*838(mm) 61.0*24.9*33.0(in)
980*905*2040(mm) 38.6*35.6*80.3(in)
740*650*880(mm) 29.1*25.6*34.6(in)
1320*755*905(mm) 59.8*29.7*35.6(in)
1635*760*900(mm) 64.4*29.9*35.4(in)
54/108/162
24/54/81
18/42/63
Y Y
Y
Y
Y
N/A N/A
N/A N/A
N/A N/A
N/A N/A N/A N/A
Y 10/Optional Optional
Y / N/A
Y / N/A
N/A / N/A
N/A
N/A
N/A
CE
CE
CE
CE
Y Y Y
N/A N/A
Product appearance and specifications are subject to change without notice
45
46
Biomedical Freezer
-40°C Biomedical Freezer
Biomedical
-25°C Biomedical Freezer
-25°C Biomedical Freezer
Model
Technical Data
Performance Control
DW-25L262 Electrical Data
Dimensions
Functions Others
47
DW-25L92
DW-25L262
Cabinet Type
Upright
Upright
Climate Class
N
N
Cooling Type
Direct Cooling
Direct Cooling
Defrost Mode
Manual
Manual
Refrigerant
CFC-Free
CFC-Free
Noise(dB(A))
40
44
Cooling Performance(°C)
-25
-25
Temp Range(°C)
-10~-25
-10~-25
Controller
Microprocessor
Microprocessor
Display
LED
LED
Power Supply(V/HZ)
220/50
220/50
Power (W)
77
90
Electrical Current(A)
0.35
0.7
Capacity(L/Cu.Ft)
92/3.2
262/9.3
Net/Gross Weight(appox)
46/51(kg)
88/88(kg)
Interior Dimensions(W×D×H)(mm)
435*410*635
480*465*1430
Exterior Dimensions(W×D×H)(mm)
597*610*860
657*685*1665
Packing Dimensions(W×D×H)(mm)
660*700*935
775*760*1755
Drawer Quantity(pcs)
3
7
Container Load(20'/40'/40'H)
50/108/108
24/48/48
High/Low Temp
Y
Y
Sensor Error
Y
Y
Certificate
CE
CE
48
Biomedical Freezer
Biomedical
Biomedical
Combined Refrigerator and Freezer
Combined Refrigerator and Freezer Refrigerator & Freezer Combination, Separate Controlled Excellent Performance
Approved by Uzbekistan MOH
520 units combined refrigerator and freezers(model: HYCD-282A) was approved by Uzbekistan MOH.
• Adjustable refrigerator compartment temperature range: 2°C to 8°C • Adjustable freezer compartment range: -20°C to -40°C
Key Function • • • • • • • •
USB port for data download Capable of recording temperature data for up to one month automatically Independent display for refrigerator section and freezer section Optional remote alarm and monitor via internet Drawers with divided compartments Shelves with divided sections Multiple alarms to detect malfunctions Multi-malfunction alarms, precautionary alarm
Model Cabinet Type Climate Class
Technical Data
Performance Control Electrical Data
Cooling Type Defrost Mode Refrigerant Noise(dB(A)) Cooling performance(°C) Temperature Range (°C) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) Net/Gross Weight(approx)
Dimensions
Interior Dimensions(W*D*H)
Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H)
HYCD-282
HYCD-282A
Functions
Accessories Others
49
Container load (20'/40'/40'H) High/Low Temperature Remote Alarm Power Failure Sensor Error Low Battery High Ambient Temp Caster Foot Test Hole Shelves/Drawers USB Interface Certificate
HYCD-282
HYCD-282A
Upright 4 Refrigertor:Forced air cooling Freezer: Direct cooling Refrigerator: Auto Freezer: Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 400 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator: 605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 775*720*1930(mm) 30.5*28.3*76(in) 21/45/45 Y Y Y Y Y Y Y Y Y Refrigerator:3/1 Freezer:0/2 Y CE
Upright 4 Refrigertor:Forced air cooling Freezer: Direct cooling Refrigerator:Auto Freezer: Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 208-230/60 400 400 2.8 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator:605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 775*720*1930(mm) 30.5*28.3*76(in) 21/45/45 Y Y Y Y Y Y Y Y Y Refrigerator:3/1 Freezer:0/2 Y CE /
50
Combined Refrigerator and Freezer
Specification
Pharmacy Refrigerator 51
52
Biomedical
Pharmacy Refrigerator
Pharmacy Refrigerator Medical Refrigerator for Pakistan Aids
The Haier pharmacy refrigerators are suitable for installation in drug stores, pharmaceutical companies, hospitals, epidemic prevention centers, and clinics.
• 1000 units pharmacy refrigerator (model: HYC-360) was successfully provided for the tender of China Ministry of Commerce for supporting Pakistan Poliomyelitis Prevention Project in 2013. • 750 units pharmacy refrigerators was successfully approved by Philippines MOHFW in 2014.
Reliability and Key Features Microprocessor control panel and digital display
Permanently lubricated condenser fan motor Locks
• High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ± 3°C • Adjustable temperature range 2~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 0.1°C • Large digital display screen • Wide voltage tolerance suitable for unstable voltage supply • Designed for ambient temperature 10~32°C with humidity below 85%
Safety • Equipped with a complete temperature alarm system featuring audible buzzer and visible flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar, remote alarm, power failure and low battery
Hermetically sealed compressor Access port Door handles
Ergonomic Design • Optimized space utilization design with multi-level and adjustable shelf height to accommodate storage requirement of pharmaceutical products of various kinds • Safety lock to prevent unauthorized access • Caster design and leveling legs • Interior light
Dual-pane glass door design, convenient and aesthetic
HYC-1378
53
54
Pharmacy Refrigerator
Leveling leg and caster
Biomedical
Pharmacy Refrigerator
Pharmacy Refrigerator
Technical Advantages • Accurate temperature control technology to make the temperature maintain 2~8 °C and increment at 0.1°C • Improved user interface with additional features include data USB port which can storage ten years data • Oversized air–cooled condenser improves the robustness of the refrigeration system reliability and refrigeration efficiency
The updated Haier Pharmacy refrigerator, more professional, more intelligent and more stable.
Optional Printer Display Panel
Lock Optional USB Port
Ergonomic Design • The new improved data storage management system is completed with a USB data port for downloading temperature data. Traceability of temperature performance is easily maintained • Heated double-pane glass door allows a clear display of stored products without condensation at 32°C and 85% relative humidity condition • LED interior light saves energy and provides bright lighting for viewing • Shelves with label holders meet demands of product archiving and retrieving
Safety Evaporator Fan Access port
• Microprocessor control, digital display, temperature uniformity within 3°C • Malfunction alarms include high/low temperature, door ajar, sensor error, power failure, low battery, remote alarm interface
HYC-390 Pull-up test at 25°C ambient
HYC-390 Pull down test at 25°C ambient
Padlock
Adjustable Shelf
30
60
90
120
0
Time (min)
Electric Heating Glass Door
15
30
45
60
Time (min)
Leveling leg and caster
Caster
HYC-390 55
56
Pharmacy Refrigerator
Sealing Strip
Biomedical
Under-Counter Pharmacy Refrigerator
Under-Counter Pharmacy Refrigerator
Precision Constant Temperature, Exquisite Installation The first Under-counter pharmacy refrigerator in China, ultra low noise design, safety lock, perfect alarm system, safety protection.
HYC-118
HYC-118A
Reliability and Key Features • High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ±3°C • Adjustable temperature range 2~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 1 °C • Designed for ambient temperature 10~32°C with humidity below 60%
Ergonomic Design • Interior LED light • Safety lock to prevent unauthorized access 57
58
Pharmacy Refrigerator
Safety • Equipped with a complete temperature alarm system featuring audible buzzer and visual flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar, power failure, remote alarm interface
Pharmacy Refrigerator
Biomedical
Pharmacy Refrigerator
Specification Cabinet Type
Technical Data
HYC-68
HYC-290
HYC-390
Upright, single door
Upright, single door
Upright, single door
Single glass door
HYC-940
HYC-940F
HYC-1378
Double glass door
Double solid door
Upright, double door
N
N
N
Forced air cooling
Forced air cooling
Forced air cooling
HYC-610
HYC-390F
Single solid door Upright, single door
N
N
N
N
N
N
Cooling Type
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Defrost Mode
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
CFC-Free
35
35
32
32
43
43
43
43
43
45
45
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
2-8
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
LED
LED
LED
LED
Fluorescent Light
Fluorescent Light
LED
LED
LED
LED
LED
LED
LED
Tmt. Range( °C) Controller
Power Supply(V/Hz) Power(W)
Capacity(L/Cu.Ft)
220~240/50 115/60 220~240/50 115/60 220~240/50
43
43
47
220~240/50 115/60 220~240/50 208~230/60 220~240/50 208~230/60 115/60
220~240/50 208~230/60
N
N
Forced air cooling Forced air cooling
115/60 220~240/50 208~230/60 115/60 220~240/50 208~230/60 220~240/50 208~230/60 115/60 220~240/50 208~230/60 115/60
45
45
220~240/50 220~240/50208~230/60 115/60
68
84
68
135
75
165
140
300
300
315
315
340
340
340
460
380
500
300
550
550
560
850
770
850
600
800
800
950
0.65
1.1
0.65
1.1
1.03
1.11
1.16
1.46
2.1
2.1
2.2
2.2
4.5
2.2
2.2
5.0
2.4
5.5
2.4
3.5
3.5
7.5
4.5
4.5
11
3
4.2
4.2
11
68/2.4
68/2.4
118/4.2
118/4.2
260/9.2
360/12.7
38/40(kg) 83.8/88.2(lbs)
390/13.8
290/10.2
610/21.6
890/31.4
890/31.4
1378/48.7
227/279(kg) 500.4/615.1(lbs) 1030*590*1425 40.6*23.2*56.1 1130*755*1980 44.5*29.7*78.0
207/259(kg) 456.4/571.1(lbs) 1030*590*1425 40.6*23.2*56.1 1130*755*1980 44.5*29.7*78.0
310/360(kg) 683.4/793.7(lbs) 1320*700*1500 52.0*27.6*59.1 1440*910*1980 56.7*35.8*78.0
1250*850*2130 49.2*33.5*83.9
1250*850*2130 1570*1010*2120(mm) 49.2*33.5*83.9 61.8*39.8*83.5(in)
530*555*1080 20.9*21.9*42.5 665*710*1665 26.2*28.0*65.6
530*555*1380 20.9*21.9*54.3 665*710*1965 26.2*28.0*77.4
204/227(kg) 449.7/500.4(lbs) 680*640*1400 26.8*25.2*55.1 780*840*1945 30.7*33.1*76.6
735*800*1800 28.9*31.5*70.9
735*800*2100 28.9*31.5*82.7
865*945*2090(mm) 34.1*37.2*82.3(in)
21/42/42
21/42/42
105/127(kg) 231.6/280.1(lbs)
116/139(kg) 255.8/306.6(lbs)
106/129(kg) 233.8/284.5(lbs)
12/26/26
8/18/18
8/18/18
6/12/12
High/Low Temperature
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Remote Alarm
Y
Y
Y
Y
N/A
N/A
Y
Y
Y
Y
Y
Y
Y
Power Failure
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Sensor Error
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Low Battery
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
N/A
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
N/A
Y
Y
N/A
N/A
Y
Y
Y
Y
Y
Y
2/1
2/1
3/1
3/1
4/-
5/-
5/-
7/-
6/-
12/-
12/-
12/-
USB Interface
N/A
N/A
N/A
N/A
N/A
N/A
Y
Optional
N/A
N/A
Y
Tmt. Recorder
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Optional
N/A
N/A
N/A
CE,UL
CE,UL
CE,UL
CE,UL
CE
CE
CE
CE
CE
CE
CE
CE
Door Ajar Caster Foot Test Hole
Accessories Shelves/Basket
Certificate
48
84
41/46(kg) 38/40(kg) 46/51(kg) 88/100(kg) 99/114(kg) 83.8/88.2(lbs) 90.5/101.5(lbs) 101.5/112.5(lbs) 218.3/251.3(lbs) 194.0/220.5(lbs) Interior Dimensions (m- 415*385*505 415*385*505 515*415*630 515*415*630(mm) 550*460*1065(mm) 550*460*1340 m)(in) 16.3*15.2*19.9 16.3*15.2*19.9 20.3*16.3*24.8 20.3*16.3*24.8(in) 21.7*18.1*41.9(in) (W*D*H) 21.7*18.1*52.8 Exterior Dimensions (m- 495*580*660 495*580*660 597*635*835(mm) 597*635*835(mm) 620*655*1720(mm) 620*655*1955(mm) m)(in) 19.5*22.8*26.0 19.5*22.8*26.0 23.5*25*32.9(in) 23.5*25*32.9(in) 24.4*25.8*67.7(in) (W*D*H) 24.4*25.8*77.0 PackingDimensions (m- 540*640*710(mm) 540*640*710(mm) 680*690*910(mm) 680*690*910(mm) 695*720*1795(mm) 695*720*2080(mm) m)(in) 21.3*25.2*28.0(in) 21.3*25.2*28.0(in) 26.8*27.2*35.8(in) 26.8*27.2*35.8(in) 27.6*28.1*71.3(in) (W*D*H) 27.6*28.1*81.9 Container load 24/48/48 108/228/228 24/48/48 108/228/228 48/102/102 48/102/102 (20'/40'/40'H) Net/Gross Weight(approx)
Others
HYC-360
N
Electrical Current(A)
Functions
HYC-260
N
Display
Dimensions
HYC-118A
Upright, solid door Upright, glass door Upright, solid door Upright, glass door
Performance Noise(dB(A))
Electrical Data
HYC-118
Climate Class
Refrigerant
Control
HYC-68A
Optional
Y
Product appearance and specifications are subject to change without notice
59
60
Pharmacy Refrigerator
Model
Blood Bank Refrigerator 61
62
Biomedical
Blood Bank Refrigerator
Blood Bank Refrigerator
The Haier BBR series provides two styles to storage systems: basket-type and drawer type.They are built in compliance with the requirements of :
Haier blood bank refrigerator are specially designed to store whole blood and blood derivatives. These refrigerators can also be used to store pharmacy and biological materials in hospitals and laboratories.
• • • •
AABB (American Association of Blood Banks) DIN 58371 (Germany, “Blutkonserven-Kühlgeräte”/Blood Refrigerators) BIS 4376-1: 1991 (UK, “Electrically operated blood storage refrigerators Specifications for closed reach-in types”)
• In 2011, Haier won MOH tender blood bank refrigerator and -86°C ULT freezer in Russia market. • In 2011, Haier won the tender "Third National HIV/AIDS Control Project (NACP III)” and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers.
LED light
Dual-pane glass, electrical heating, free from condensation.
Permanently lubricated evaporator fan motor
Access port
Reliability • Microprocessor controlled forced-air cooling with electrical heat compensation system • Digital temperature display for upper and lower sections in chamber with 0.1 °C resolution
Key Features • Consistent cabinet temperature 2-6°C • High-tech integrated sensors to display and control temperature • Standard temperature recorder (Optional for HXC-158) • Auto-defrost to remove moisture on cooling surface • Large digital display for ease of observation
Safety
Temperature recorder
Hermetically sealed compressor
Ergonomic Design Leveling legl and caster
HXC-358B
63
• Safety lock to prevent unauthorized access • Storage space designed for easy sorting of a variety of blood products • Caster design and interior light • Optional baskets or stainless steel drawers 64
Blood Bank Refrigerator
Blood basket or drawer is optional
• Dual displays of operational parameter temperature recorder display) • Built-in backup battery to display temperature and to operate audible and visual alarm systems for up to 48 hours without ac power • Three types of alarm alerts: Buzzer, Flashing light, and remote alarm • Five alarm conditions: High /low temperature, power failure, sensor error, door ajar, low voltage in backup battery
Biomedical
Blood Bank Refrigerator
Light on when LED displaying upper sensor temperature
Blood Bank Refrigerator
Light on when LED displaying lower sensor temperature
A constant light indicates normal power supply, a flashing light indicates power supply failure
Both lights on when LED displaying the average temperature of upper and lower temperature
The standard drawers can be optionally fitted with adjustable dividers. This guarantees neatly and clearly arranged storage of your goods.
HXC-608 Pull down test at 32°C ambient 36 32 28
A flashing light indicates an alarm condition
24
Temperature(°C)
To cancel buzzing To adjust the displayed temperature To test alarm function To calibrate upper sensor, lower sensor and control sensor
20 16 12 8 4 0
To select sensor to calibrate
10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160
Time (min) To cancel calibration
HXC-608 Pull-up test at 32°C ambient 36
Alarm
Alarm Triggering Condition
High Temperature
Temperature reaches the warm alarm limit
Low Temperature
Temperature reaches the low alarm limit
Power Failure
Equipment loses power
Probe Failure
1.Main cabinet temperature control sensor fails 2.Condenser sensor fails 3.Ambient sensor fails 4.Heat exchanger sensor fails
32 28
Battery capacity runs low or battery switch is not turned on
Door Ajar
Door open exceeds 600s
65
20 16
Blood Bank Refrigerator
Low Battery
Temperature(°C)
24
12 8 4 0 10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160
Time (min)
66
Biomedical
Blood Bank Refrigerator
Blood Bank Refrigerator
Application
Advantages 2-6°C
Safety Dual-pane electrical heated glass door Multilayer adjustable shelves Baskets or optional stainless steel drawers Each shelf can be labelled E
Microprocessor control, three inner fans maintain temperature uniformity within 2~6°C and quick recovery after door openings
Defrosting is performed automatically with temperature sensor system, temperature rise during defrost is minimal, further protecting the contents
Ergonomic Design Self-closing door It provides a clear view of stored items through the large glass windows Two access ports, users can test the inner temperature freely Built-in 7-day circular chart recorder with USB port Bright, energy-efficient LED interior lighting CFC-free refrigerant, environmental friendly "One lock one key" to safeguard valuable contents
67
48
68
Blood Bank Refrigerator
sensor error
Blood Bank Refrigerator
Biomedical
Blood Bank Refrigerator
Specification Model
HXC-158
HXC-358
Technical Data
Performance Control Electrical Data
HXC-1308
HXC-158B
HXC-608B
HXC-358B
HXC-1308B
Drawer-Type
Climate Class
ST
ST
ST
N
ST
ST
ST
N
Cooling Type
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Forced air cooling
Defrost Mode Refrigerant Noise(dB(A)) Temperature Range( °C) Ambient Temperature (°C) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) Blood Storage Capacity (450ml blood bags) Net/Gross Weight(approx)
Dimensions
HXC-608
Basket-Type
Type
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
CFC-Free 42 2-6
CFC-Free 43 2-6
CFC-Free 43 2-6
CFC-Free 45 2-6
CFC-Free 42 2-6
CFC-Free 43 2-6
CFC-Free 43 2-6
CFC-Free 45 2-6
10-38
10-38
10-38
16~32
10-38
10-38
10-38
16-32
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Microprocessor
LED
LED
LED
LED
LED
LED
LED
LED
220~240/50/60
220~240/50 /60
220~240/50 /60 115/60
220~240/50
220~240/50/60
220~240/50/60
220~240/50/60
220~240/50
350
460
490
560
850
350
460
490
850
3.5
7.5
2.6
3
4.2
2.6
3
3.5
4.2
158/5.6
358/12.7
608/21.5
1308/46.2
158/5.6
358/12.7
608/21.5
1308/46.2
84
200
312
624
84
200
360
720
107/120(kg) 235.9/264.6(lbs)
158/174(kg) 348.3/383.6(lbs)
204/227(kg) 449.7/500.4(lbs)
310/360(kg) 683.4/793.7(lbs)
113/126(kg) 249.1/277.8(lbs)
165/181(kg) 363.8/399.0(lbs)
211/234(kg) 465.2/515.9(lbs)
335/385(kg) 738.5/848.8(lbs)
Interior Dimensions (W*D*H) Exterior Dimensions (W*D*H)
460*370*950(mm) 620*490*1160(mm) 24.4*19.3*45.7(in) 18.1*14.6*37.4(in) 560*570*1530(mm) 720*690*1730(mm) 28.3*27.2*68.1(in) 22.0*22.4*60.2(in)
680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in)
1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in)
460*370*950(mm) 18.1*14.6*37.4(in) 560*570*1530(mm) 22.0*22.4*60.2(in)
620*490*1160(mm) 24.4*19.3*45.7(in) 720*690*1730(mm) 28.3*27.2*68.1(in)
680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in)
1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in)
Packing Dimensions (W*D*H)
645*675*1680(mm) 795*805*1870(mm) 31.3*31.7*73.6(in) 25.4*26.6*66.1(in)
865*945*2090(mm) 1570*1010*2120(mm) 61.8*39.8*83.5(in) 34.0*37.2*82.3(in)
645*675*1680(mm) 25.4*26.6*66.1(in)
795*805*1870(mm) 31.3*31.7*73.6(in)
865*945*2090(mm) 34.0*37.2*82.3(in)
1570*1010*2120(mm) 61.8*39.8*83.5(in)
27/54/54
14/30/30
12/26/26
6/12/12
Container load (20'/40'/40'H)
27/54/54
14/30/30
12/26/26
6/12/12
Y
Y
Y
Y
Sensor Error
Y
Y
Y
Y
Y
Y
Y
Y
Low Battery
Y
Y
Y
Y
Y
Y
Y
Y
High/Low Temperature
Functions
Accessories
Others
Door Ajar
Y
Y
Y
Y
Y
Y
Y
Y
Remote Alarm
Y
Y
Y
Y
Y
Y
Y
Y
Caster
Y
Y
Y
Y
Y
Y
Y
Y
Leveling Leg
Y
Y
Y
Y
Y
Y
Y
Y
Test Hole
Y
Y
Y
Y
Y
Y
Y
Y
4/4
5/20
6/24
12/48
_
_
_
_
Shelves/Baskets Drawers/Inner doors
-/2
-/3
-/3
-/6
4/-
5/-
6/-
12/-
USB Interface
Optional
Optional
Optional
Y
Optional
Optional
Optional
Y
Temperature Recorder
Optional
Y
Y
Y
Y
Y
Y
Y
CE
CE
CE
CE
CE
CE
CE
CE
Certificate
Product appearance and specifications are subject to change without notice
69
70
Blood Bank Refrigerator
Power Failure
Vaccine Storage Solution
71
72
Vaccine & Icepack Freezer
Biomedical
Vaccine & Icepack Freezer
WHO/UNICEF qualified supplier The refrigerators are designed to store vaccine, freeze icepack, pharmaceuticals and so on. Applications could be found in epidemic prevention, clinics,hospitals, research institutes etc.
• From 2004 until now, Haier awarded the tender from India MOHFW, WHO, UNICEF, Africa market to supply about 50,000 units icepack freezers and ice-lined refrigerators • 2009, World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116 • 2011, Haier obtained the LTA of Ice-Lined Refrigerator and Vaccine Freezer. Haier is the long term supplier of UNICEF • 2014, Haier broke the European & USA monopoly of the vaccine refrigerator in Africa market -1000 units was awarded by the PFSA Ethiopia
HBD-116
HBD-286
Cabinet Type
Chest
Chest
Ambient Temperature
<43°C
<43°C
Cooling Type
Direct cooling
Direct cooling
Defrost Mode
Manual
Manual
CFC-Free
CFC-Free
Technical Data
Refrigerant Noise(dB(A))
HBD-286
HBD-116
Performance Control
Refrigeration System
Ergonomic Design
• Famous brand high quality compressor • CFC-free high density foam insulation • Optimized refrigeration system design
• • • • •
Temperature Control
Electrical Data
HBD-286 Pull down test at 43 °C ambient
HBD-286 Pull-up test at 43 °C ambient 50 43
30
20
20
Temperature
Temperature
30
0 -10 -20
43
40
Dimensions
Mechanical
LCD
LCD 220~240/50
Power(W)
138
166
185
Electrical Current(A)
1.05
1.65
1.3
Power Consumption: stable running(KWh/24h)
3.01
3.53
3.48
Power Consumption: cool down test(KWh/24h)
3.25
3.25
3.71
more than 3hrs(up to -5°C)
more than 5hrs(up to -5°C)
Vaccine Storage Capacity(L/Cu.Ft)
97/3.4
258/9.1
Gross Volume(L/Cu.Ft)
121/4.3
286/10.1
waterpack freezing capacity
12kg/24h
16.8kg/24h
waterpack storage capacity
136*0.6L
310*0.6L
Interior Dimensions(W*D*H)
Packing Dimensions(W*D*H)
-10
Mechanical
208~230/60
Exterior Dimensions(W*D*H)
0
44 -15~-25
220~240/50
Net/Gross Weight(approx)
10
43 -15~-25
Display
Holdover Time at 43°C
50
10
Controller
Power Supply(V/Hz)
Safety lock for unauthorized access Corrosion-proof interior and ease of cleaning Shelving designs for various sizes of storage baskets Drainage system for ease of cabinet cleaning LCD temperature display
• Digital display • Inner temperature range is -15°C to -25°C
40
Temperature Range(°C)
-20
50/55(kg)
110.3/121.3(lbs)
79/85(kg)
174.2/187.4(lbs)
497*457*655(mm) 19.6*18.0*25.8(mm) 1067*457*655(mm)
42.0*18.0*25.8(in)
670*630*818(mm)
26.4*24.8*32.2(in)
1240*630*818(mm)
48.8*24.8*32.2(in)
(Paper)755*760*880(mm)
29.7*29.9*34.6(in)
(Paper)1325*760*880(mm)
52.2*29.9*34.6(in)
(Wooden)820*820*1045(mm)
32.3*32.3*41.1(in)
(Wooden)1375*820*1045(mm)
54.1*32.3*41.1(in)
28/56/56(Wooden)
24/54/81(Paper)
-30
Container load (20'/40'/40'H)
-40
-40
Foot
Y
Y
-50
-50
Baskets
2
3
CE,WHO/PQS
CE,WHO/PQS
-30
0
05
10
15
20
25
30 35 40 45
50
55
60
Time (H)
Accessories 0
05
10
15
20
25
30 35 40 45
Time (H)
73
50
55
60
Others
Certificate
42/90/135(Paper)
74
16/32/32(Wooden)
Vaccine & Icepack Freezer
Model
Biomedical
Ice-Lined Refrigerator
Ice-Lined Refrigerator
Refrigeration System • Optimized refrigeration system design • Built-in ice packs maintain 2°C to 8°C for more than 25 hours at 43°C ambient • CFC-free high density foam insulation • Complied with WHO/UNICEF standards
Temperature Control • Digital temperature display • Inner temperature range is 2°C to 8°C Technical Data
Ergonomic Design • Door lock for storage safety • Stainless steel interior for ease of cleaning and corrosion proof
Performance Control
Electrical Data
1.34 4.01 27hrs18mins
36hrs17mins
31hrs24mins
53
Functions Accessories Others Product appearance and specifications are subject to change without notice
75
76
Ice-Lined Refrigerator
Dimensions
For Solar-powered Vaccine Refrigerator, electricity and fuel are unneeded. It provides with convenience to store vaccine for the areas without power or power unstable regions, especially frequent blackout. This kind of refrigerator can also be used for vaccine storage in developing countries. Haier has repeatedly taken part in the project of children health protecting in WHO,UNICEF, Africa and other developing regions, providing the solutions of vaccine storage security.
Solar Direct Drive Vaccine Refrigerator
Model
WHO/UNICEF qualified supplier Haier successfully won the UNICEF tender of 100 units SDD Refrigerator HTC-60H for aiding North Korea project . 2014 Haier has been awarded 1,000 units SDD Vaccine Refrigerator of HTC-60H PO from MOH of Ethiopia.
Technical Data
Cabinet Type
Chest
Ambient Temperature(°C)
5~43°C
Cooling Type
Forced air cooling
Refrigerant
Performance
Storage Security
Control The product using ambient temperature 5~43°C Forced air cooling system designed to provide stable and uniform chamber temperature LCD temperature display to read the visual temperature High and low temperature and sensor error alarm system,multiple built-in protection system Corrosion-resistant stainless steel liner Lock design, safe to storage the vaccine Keeping inside temperature at 2-8°C, in the condition that ambient temperature is 43°C power outage for 110 hours , safe for vaccine storage
HTC-60H
HTC-60H
Electrical Data
Temperature Control Microcomputer control, guarantee the accurate temperature Temperature measurement function, the temperature inside chamber is accordance with the display temperature
Ergonomic Design Solar-driven, green and environment friendly Temperature controller is easy to view, ancillary battery for display without sunshine Low noise
CFC-Free
Noise ( dB(A))
30
Temperature Range(°C)
2~8
Controller
Microprocessor
Display
LCD temperature display
Power supply(VDC)
12
Maximal Current(A)
6
Energy Consumption:stable running(KWh/24h)
0.78
Energy Consumption:cool down test(KWh/24h)
0.67
Holdover time at 43°C
109hrs 21mins
Autonomy Time
110hrs 37mins
Solar Radiation Reference Period
3.5kwh/㎡/day
Voltage of Solar Panel
12V
Power of Solar Panel
120W*3
Vaccine Storage Capacity(L/Cu.Ft)
21/0.7
Gross Volume(L/Cu.Ft)
60/2.1
Net/Gross Weight(approx)
EXTERNAL DIGITAL DISPLAY The current temperature is digital display. There is no need for daily adjustment, as the entire system has been calibrated before delivery from the factory and it is self-regulating.
Dimensions
88/110(kg) 194/243(lb)
Interior Dimensions(W*D*H)
245*450*610(mm) 9.6*17.7*24.0(in)
Exterior Dimensions(W*D*H)
788*654*875(mm) 31.0*25.7*34.4(in)
Packing Dimensions(W*D*H)
865*770*1080(mm) 34.1*30.3*42.5(in)
Container load(20'/40'/40'H) Cooling curve at ambient temperature of 43℃ 50
50
43℃
Temperature(℃)
Temperature(℃)
96hrs
20
10
8℃
40
30
109hrs21mins
19
31
43
55
67
81
93 96
10
8℃ 2℃ 12
Time(H)
Y
Sensor Error
Y
Low Battery
Y
Accessories
Baskets
2
Others
Certificate
Alarm
0 7
High/Low Temperature
20
2℃ 0
1470*680*35(mm) 57.8*26.8*1.4(in)
Solar Panel(L*W*D)
43℃ 40
30
36/78/78
Holdover time curve at ambient temperature of 43℃
24
36
48
60
72
84
96
CE/WHO/PQS
109
Time(H)
77
78
Solar Direct Drive Vaccine Refrigerator
Solar Direct Drive Vaccine Refrigerator
Biomedical
Solar Direct Drive Combined Refrigerator/Freezer
Solar Direct Drive Combined Refrigerator/Freezer
Model
Technical Data
HTCD-160
Cabinet Type
Upright
Ambient Temperature(°C)
5~43°C Direct cooling
Cooling Type
Manual
Defrost Mode(Freezing Chamber)
CFC-Free
Refrigerant
38
Noise (dB(A)) Temperature Range(°C)
Display panel
Cooling Chamber Vaccine Storage Capacity(L/Cu.Ft) Performance Freezing Chamber
Control
Electrical Data
HTCD-160 Handgrip
120/4.2
Temperature Range(°C)
≤-10
Gross volume (L/Cu.Ft)
40/1.4
Waterpack storage capacity(kg)
10.68
Controller
Temperature control
The internal temperature of the cooling chamber is not lower than 0°C due to its anti-freeze function. Under ambient temperature of 43 degrees, the inner box temperature will be no more than 8°C after power outage for more than 121 hours and no more than 10°C after power outage for more than 160 hours, so as to guarantee safe storage of vaccine. The freezing chamber can freeze 2.08kg of ice every day, with storage of 10.68kg in total. Solar energy temperature display,clear temperature in the inner box. Lock catch designed to match padlock Cooling chamber meet the A level WHO requirements of anti-freezing protection.
Microprocessor Control; guarantee temperature precision.
Ergonomic Design
Display
Solar LED temperature display
Power supply(VDC)
24
Maximal Current(A)
9
Energy Consumption:stable running(KWh/24h)
0.86
Energy Consumption:cool down test(KWh/24h)
0.86
Holdover time at 43°C
160hrs8mins
Autonomy Time
121hrs27mins
Solar Radiation Reference Period
3.5kwh/㎡/day
Voltage of Solar Panel
24V
Power of Solar Panel
255W*3
Equipped with USB charging socket , for charging the mobile phone,etc Eliminate storage battery and only provide solar energy power, which is green and friendly environment. There is illumination on temperature display screen,it can display the inner box temperature even though it is powered off, which is convenient for administration. The refrigerating chamber and freezing chamber both have the separate refrigerating systems; the two independent refrigerating systems ensure safety of the vaccine storage. Sensor error alarm. Low noise.
79
160/186(kg)353/410(lb) Freezing Chamber
560*520*150(mm) 22.0*20.5*5.9(in)
Cooling Chamber
545*500*530(mm) 21.4*19.7*20.8(in)
Interior Dimensions(W*D*H)
Dimensions
Exterior Dimensions(W*D*H)
865*825*1695(mm) 34.1*32.5*66.7(in)
Packing Dimensions(W*D*H)
960*890*1860 (mm) 37.8* 35.0*73.2(in)
Container load(20'/40'/40'H)
12/26/26 1640*990*35(mm) 64.6*39.0*1.4(in)
Solar Panel(L*W*D) Alarm Accessories Others
2.08kg/24h Microprocessor
Net/Gross Weight(approx)
Storage Security
100/3.5
Gross Volume(L/Cu.Ft)
Waterpack freezing capacity(kg/24h)
Lock catch designed to match padlock
2~8
Sensor Error
Y
Shelves
2(Cooling Chamber)
Certificate
CE/WHO/PQS
80
Solar Direct Drive Vaccine Refrigerator
Biomedical
Solar Direct Drive Vaccine Refrigerator Model
HTC-40
HTC-110
Chest
Chest
5~43°C
5~43°C
Cooling Type
Direct cooling
Direct cooling
Defrost Mode
/
/
CFC-Free
CFC-Free
Noise ( Db(A))
<30
<30
Temperature Range(°C)
2~8
2~8
Microprocessor
Microprocessor
Solar LED temperature display
Solar LED temperature display
Power supply(V)
24
24
Maximal Current(A)
5
5
Energy Consumption:stable running(KWh/24h)
0.69
0.58
Energy Consumption:cool down test(KWh/24h)
0.71
0.62
Holdover time at 43°C
122hrs18mins
106hrs17mins
Autonomy Time
117hrs18mins
96hrs24mins
Solar Radiation Reference Period
3.5kwh/㎡/day
3.5kwh/㎡/day
Voltage of Solar Panel
24V
24V
Power of Solar Panel
180W *2
180W *2
Vaccine Storage Capacity(L/Cu.Ft)
22.5(0.8)
59 (2.08)
Gross Volume(L/Cu.Ft)
40L(1.4)
110L(3.88)
55/75(121/165)
69/92(151/202)
Interior Dimensions(W*D*H)
200*345*575(mm)
545*345*575 (mm)
Exterior Dimensions(W*D*H)
788*645*875(mm)
1128*645*875(mm)
Packing Dimensions(W*D*H)
835*770*1080 (mm)
1175*770*1080 (mm)
Container load(20'/40'/40'H)
36/78/78
30/60/60
1335*990*40(mm) 52.5*39*1.57
1335*990*40(mm) 52.5*39*1.57
High/Low Temperature
N
N
Sensor Error
Y
Y
Low Battery
/
/
Baskets
2
4
Shelves
-
-
CE/WHO/PQS
CE/WHO/PQS
Data Logger
Y
Y
Freezer Protection Level
A
A
Freezer Gross Volume (L):
-
-
Waterpack Storage Capacity(kg)
-
-
Waterpack Freezing Capacity(kg/24h)
-
-
Cabinet Type Ambient Temperature(°C)
This product is designed to store vaccine, reagents, etc. Applicable to the sunny and power shortage remote area. Technical Data
Refrigerant
Performance Control
Solar energy display panel
Display
Electrical Data
HTC-40
Net/Gross Weight(approx)
HTC-110 Dimensions
Product features Solar direct drive,green and environment-friendly Microprocessor control, solar energy display panel for showing interior temperature Water tank for keeping interior temperature, holding time is longer when power off Cooling chamber meet the A level WHO requirements of anti-freezing protection Patented technology, better temperature uniformity Inner door offer additional temperature protection Wide temperature range, working normally at 5-43°C ambient
Solar Panel(L*W*D)
Functions
Accessories
Ergonomic design Safety lock for unauthorized access control Equipped with USB charging socket,for charging the mobile phone, etc Equipped with storage basket, easy-reach retrieval of samples Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with handles on both sides of the cabinet, easy to move
81
Controller
Certificate
Others
82
Solar Direct Drive Vaccine Refrigerator
Solar Direct Drive Vaccine Refrigerator
Biomedical
Solar Direct Drive Vaccine Freezer Model
This product can be used to freeze ice pack, applicable to the sunny and power shortage remote area. Technical Data
HTD-40
Cabinet Type
Chest
Ambient Temperature(°C)
≤43°C
Cooling Type
Direct cooling
Defrost Mode
Manual CFC-Free
Refrigerant
Performance Control
Electrical Data
Noise ( Db(A) )
<30
Temperature Range(°C)
≤-10 Microprocessor
Controller
Solar LED temperature display
Display Power supply(V)
24
Maximal Current(A)
5
Energy Consumption:stable running(KWh/24h)
0.46
Energy Consumption:cool down test(KWh/24h)
0.50
Holdover time at 43°C
-
Autonomy Time
-
Solar Radiation Reference Period
Solar energy display panel
Voltage of Solar Panel
24V
Power of Solar Panel
180W *2
Vaccine Storage Capacity(L/Cu.Ft)
Product features Solar direct drive, green and environment-friendly Solar energy display panel for showing interior temperature, the interior temp less than -10°C High-performance refrigeration Wide temperature range, working normally less than 43°C ambient Heavy insulation layer, high-efficiency of heat insulation
Safety lock for unauthorized access control Equipped with storage basket, easy-reach retrieval of samples Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with USB charging socket, for charging the mobile phone, etc
Interior Dimensions(W*D*H)
265*370*575(mm)
Exterior Dimensions(W*D*H)
788*654*875(mm)
Packing Dimensions(W*D*H)
835*770*1080 (mm)
Container load(20'/40'/40'H)
36/78/78 1335*990*40(mm) 52.5*39*1.57
Solar Panel(L*W*D)
Functions
Accessories
Ergonomic design
65/85(143/187)
Net/Gross Weight(approx) Dimensions
High/Low Temperature
N
Sensor Error
Y
Low Battery
/
Baskets
2
Shelves
CE/WHO/PQS
Certificate
Others
Data Logger
-
Freezer Protection Level
/
Freezer Gross Volume (L):
48(1.7)
Waterpack Storage Capacity(kg)
16.8kg
Waterpack Freezing Capacity(kg/24h)
83
48(1.7)
Gross Volume(L/Cu.Ft)
HTD-40
3.5kwh/㎡/day
84
2.4 kg/24h
Solar Direct Drive Vaccine Refrigerator
Solar Direct Drive Vaccine Freezer
Biomedical
Solar Direct Drive Combined Refrigerator/Freezer
Solar Direct Drive Combined Refrigerator/Freezer Model
The refrigerator with freezer combination, this product can be used to store vaccine, reagent and freeze ice pack. Applicable to the sunny and power shortage remote area.
Technical Data
HTCD-90
Cabinet Type
Chest
Ambient Temperature(°C)
5~43°C
Cooling Type
Direct cooling
Defrost Mode
Manual CFC-Free
Refrigerant
<38
Noise (Db(A) ) Performance Control
Electrical Data
Solar energy display panel
freezer ≤-10 refrigerator:2~8
Temperature Range(°C)
Microprocessor
Controller
Solar LED temperature display
Display Power supply(V)
24
Maximal Current(A)
7
Energy Consumption:stable running(KWh/24h)
0.86
Energy Consumption:cool down test(KWh/24h)
0.81
Holdover time at 43°C
137hrs47mins
Autonomy Time
114hrs56mins
Solar Radiation Reference Period
3.5kwh/㎡/day
Voltage of Solar Panel
24V
Power of Solar Panel
180W *4
Vaccine Storage Capacity(L/Cu.Ft)
37.5 (1.3) freezer:32 (1.1)
Gross Volume(L/Cu.Ft)
HTCD-90
refrigerator:58L (2.1) 83/108(183/238)
Net/Gross Weight(approx)
Product features
Dimensions
The refrigerating chamber and freezing chamber both have the separate refrigerating systems; the two independent refrigerating systems ensure safety of the vaccine storage
Solar direct drive,green and environment-friendly Microprocessor control, solar energy display panel for showing refrigerator and freezer interior temperature, refrigerator temperature range is 2~8°C, freezer temperature is less than -10°C Cooling chamber with water tank for keeping interior temperature, holding time is longer when power off Cooling chamber meet the A level WHO requirements of anti-freezing protection Patented technology, better temperature uniformity Wide temperature range, working normally at 5-43°C ambient
Safety lock for unauthorized access control Equipped with USB charging socket, for charging the mobile phone, etc Equipped with storage basket, easy-reach retrieval of sample Low noise Aluminum chamber interior, corrosion-proof and ease to clean Equipped with handles on both sides of the cabinet, easy to move
Freezer chamber:170*370*575(mm)
Exterior Dimensions(W*D*H)
1128*654*875(mm)
Packing Dimensions(W*D*H)
1175*770*1080 (mm)
Container load(20'/40'/40'H)
30/60/60 1335*990*40(mm) 52.5*39*1.57
Solar Panel(L*W*D) Functions
Accessories
Ergonomic design
Cooling chamber:270*345*555(mm)
Interior Dimensions(W*D*H)
High/Low Temperature
N
Sensor Error
Y
Low Battery
/
Baskets
4
Shelves
CE/WHO/PQS
Certificate
Others
Data Logger
Y
Freezer Protection Level
A
Freezer Gross Volume (L):
32(1.1)
Waterpack Storage Capacity(kg)
12.52kg
Waterpack Freezing Capacity(kg/24h) 85
86
2.43kg/24h
Solar Direct Drive Vaccine Refrigerator
Biomedical
Walk-In Cold/Freezer Room
Walk-In Cold/Freezer Room Integral Cold Store Unit • The cold room is suitable to freeze or refrigerate relevant articles for medical service, scientific research,agricultural, biological and chemical industries, etc. Its interior tempera- ture can be controlled respectively within the range of 0~10°C or 0~-25°C
Haier walk-in cold room is for storage of vaccines, and the complete unit is also designed for installation in a housed area such as a warehouse in order to meet designed temperature standards. Haier’s WICs & WIFs have passed WHO / PQS and is long term supplier of UNICEF. The units have been installed in India, Guinea, South Sudan, Pakistan, Burundi, Uzbekistan, etc.
Features of the Cold Room • The cold room for vaccines and medicines is controlled and adjustable within the range of 0~10°C or -15~-25°C with resolution of 0.1°C • Insulation material CFC-free polyurethane foamed-inpiece, density 42kg/cbm • Insulation thickness 100 mm, K-value 0.22 W/m2K or better Internal and external surfaces of hot-dipped galvanized steel sheet,white polyester coating and floor clad with non-slip material • Rooms equipped with tungsten lighting and with an external switch with pilot lamp • Rooms equipped with shelving system on three walls, material stove enameled steel, galvanized steel,stainless steel, aluminum or plastic slatted adjustable shelving units to carry vaccine in packages, 5 levels, 450-600 mm deep, adjustable • Dual refrigeration system is equipped. When one set of system is working, the other system is for backup • Forced air-cooled condenser refrigeration units • Door equipped with heavy duty hinges and lock with internal safety release. Automatic defrosting CFC-free refrigerant • System to be offered with manual change over switch as standard • Temperature recorder and audible alarm system
Technical Characteristics of the Refrigerating Unit • The LYJ series of machine, called mono block, that integrates evaporator, condenser, compressor, electrical control units into one compact body, can be widely used for cold storage rooms of temperature of -5°C~5°C or -15°C~-20°C, in hotels, restaurants, medicines, agricultural, chemicals industries all other place where cold storage is needed. This series products feature below • With very compact structure • With TECUMSEH hermetic compressors, high efficient in-grooved copper tube and aluminum fin heat exchangers and world famous brand refrigeration parts for all products • The electronic control boards are with functions of automatic temperature set, control, and electric heater defrosting.Protection devices for over loading, over heating, lack of phase, high & low pressure etc • Safe, easy, and low cost for installation and operation
Freezer Room HRZK-40D
HRZK-20D
Power(W)
5300
2630
Refrigeranting Output(W)
4200
2060
40
20
Model Defrost Mode Refrigerant Internal Temperature Range(°C) Evaporator Temperature(°C) Power Supply(V/Hz)
Capacity(m3)
Temperature Recorder • Upper and lower limits +50°C to -30°C • Accuracy ±1°C • Resolution ±0.5°C • Minimum acceptable recording period between chart changes is 7 days • USB interface is equipped
Condensation Temperature(°C) Density(Kg/Cbm) K-Value(m2K)
Separate Design
Insulation Thickness(mm) Certificate
•Haier walk-in cold/freezer room can separately design according to the site situation and construction drawings
_
87
88
89
90
Biological Safety Cabinet
Biological Safety Cabinet
Biological safety cabinet is designed to protect operator, laboratory environment and samples from being exposed to the infective aerosol produced when the sample is bacteria strains, diagnostic material, and other infective subjects. It provides the operators with a more comfortable and safer working condition. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring. And it has been the important basis of sample safety and environment security.
Patent Intelligent Constant Air Velocity The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system
Low Noise Safety Energy-saving Mode When the human body detecting module detects under the intelligent mode that the person is outside the operating area for over 15 minutes, the microcomputer program will automatically switch the safety cabinet to Low Noise Safety energy conservation mode, so as to realize noise reduction and energy conservation and to improve the service life of the filter
Ultra Low Penetration Air Filter System
Professional Air-flow Distribution Module Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise <62dBA
Camfil ULPA filter
Ultra Low Penetration Air Filter System
Intelligent constant air velocity patent technology
Sweden Camfil (ULPA)filter are tested to a typical efficiency of > 99.999% for 0.12 micron particles. ULPA Filter provides vertical laminar flow to the worktable, so as to protect samples from pollution
The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system
Patent Technology of Air Flow Disruption Adopt the patent technology of air flow disruption on the upper edge and both sides of the front window (Patent No. ZL200520125549.X) to eliminate the safety protection blindness. Adopt the patent technology of side air flow disruption design to eliminate the exposure of microorganism
304 stainless steel operation platform and internal wall Stainless steel operation platform without screws, no accumulation of contaminant Dismountable air in-flow plate, easy to clean and disinfect Concaved operation platform, waste liquid easily collected
Unique Drop-down Front Glass Window HR1200-IIA2
Digital microprocessor control system
Remove the hand-placing frame by hand, and pull down the front glass window to clean the upper part of the glass and to avoid dead corners
Dismountable Platform-type Hand-placing Frame Platform-type hand-placing frame is comfortable to use and helps to relieve fatigue
LCD display Real-time display of key parameters: downflow velocity, inflowvelocity, airflow volume, static pressure, negative pressure,accumulative running time of fan and UV lamp, left lifetime of filter Sound & light alarming function UV sterilization reservation setting function
Professional air flow distributiondesign Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise 〈62dBA
91
V-shaped air inlet design
Swivel caster, Internal thread support leg
CFDA
92
Biological Safety Cabinet
Biological Safety Cabinet
304 Stainless Steel Operation Platform and Internal Wall
American AAF ULPA filter are tested to a typical efficiency of >99.999% for 0.12 micron particles Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy
Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy
Digital microprocessor control system for easy operation Intelligent alarming system Multiple interlocking functions eliminate potential safety problems caused by misoperation.
Removable stainless steel work surface makes cleaning easier
Stainless steel operation platform without screws, no accumulation of contaminant Dismountable air in-flow plate, easy to clean and disinfect Internal wall is constructed by a single plate, and the12mm arc angle conner leaves no cleaning blind area The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintaining Concaved operation platform, waste liquid easily collected Adjustable supporter (0-75mm) without exposed screw thread, preventing the germs from multiplying
Ultra Low Penetration Air Filtration System American AAF ULPA filter Tested to a typical efficiency of 99.9995% for 0.12 micron particles Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection
High Efficiency Blower System Ergonomic angled design to improve comfort
The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance Self cooling system reduces energy consumption while enhancing reliability
Adjustable foot
HR40-IIA2
Reverse centrifugal fan
93
Double-side air inflow design decreases running noise
Air velocity auto-compensation function guarantees stable wind speed
94
Provide uniform airflow by adjusting working voltage of fan
Biological Safety Cabinet
Working Voltage& Frequency
Biological Safety Cabinet
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
Power(VA)
1400
1500
1300
1300
1300
1300
1500
Power of Blower(W)
335
475
650
350
350
650
505
Airflow Circulation
70% downflow,30% exhaust
70% downflow,30% exhaust
70% downflow,30% exhaust
70% downflow, 30% exhaust
70% downflow, 30% exhaust
70% downflow, 30% exhaust
100% exhaust
Main Filter Typical Effiency
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12µm
ULPA,99.9995%@0.12µm
ULPA,99.9995%@0.12µm
ULPA,99.9995%@0.12µm
Exhaust Filter Typical Effiency
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12um
ULPA,99.9995%@0.12µm
HEPA,99.995%@0.3µm
ULPA,99.9995%@0.12µm
HEPA,99.99%@0.3µm
Camfil
Camfil
AAF
AAF
AAF
AAF
AAF
Downflow Velocity(m/s)
0.33
0.34
0.31
0.31
0.28
0.28
0.28
Inflow Velocity(m/s)
0.55
0.55
0.55
0.55
0.55
Fluorescent Lamp Intensity(Lux)
900
900
900
≥1100
≥1100
290/315(kg) 639.3/694.5(lbs)
320/347(kg) 705.4/765(lbs)
350/375(kg) 771.6/826.7(lbs)
220/248(kg) 485.0/546.7(lbs)
258/293(kg) 568.8/646.0(lbs)
Internal Dimensions(W*D*H)
920*620*650(mm) 36.2*24.4*25.6(in)
1220*620*650(mm) 48.1*24.4*25.6(in)
1520*620*650(mm) 59.9*24.4*25.6(in)
900*610*680(mm) 35.4*24.0*26.8(in)
External Dimensions(W*D*H)
1080*845*2160(mm) 42.5*33.3*85.0(in)
1380*845*2160(mm) 54.3*33.3*85.0(in)
1680*845*2160(mm) 66.2*33.3*85.0(in)
Packing Dimensions(W*D*H)
1145*920*1690(mm) 69.1*36.2*66.5(in)
1470*920*1690(mm) 57.9*36.2*66.5(in)
75mm adjustbale height
Filter's Brand
Net/Gross Weight
Supporter Container load (20'/40'/40'H) Alarm Certificate
0.55
0.55 ≥1100
1167*610*680(mm) 45.9*24.0*26.8(in)
≥1100 340/380(kg) 749.5/837.8(lbs) 1585*610*680(mm) 62.4*24.0*26.8(in)
1167*610*680(mm) 46.0*24.0*26.8(in)
1100*790*2200(mm) 43.3*31.1*86.6(in)
1360*790*2200(mm) 53.5*30.7*86.6(in)
1780*790*2200(mm) 70.1*31.1*86.6(in)
1360*790*2400(mm) 53.5*31.1*94.5(in)
1755*920*1690(mm) 69.1*36.2*66.5(in)
1160*920*1690(mm) 45.7*36.2*66.5(in)
1420*920*1690(mm) 55.9*36.2*66.5(in)
1840*920*1690(mm) 72.4*36.2*66.5(in)
1420*920*1850(mm) 55.9*36.2*72.8(in)
75mm adjustbale height
75mm adjustbale height
75mm adjustable height
75mm adjustable height
75mm adjustable height
75mm adjustable height
12/24/24
8/16/16
6/12/12
10/20/20
8/16/16
4/10/10
8/16/16
Sound and Flash
Sound and Flash
Sound and Flash
Sound and Flash
Sound and Flash
Sound and Flash
Sound and Flash
CE,EN12469,CFDA
CE,EN12469,CFDA
CE,EN12469,CFDA
CFDA
EN12469,CFDA,CE
CFDA
CFDA
280/308(kg) 617.3/694.5(lbs)
Product appearance and specifications are subject to change without notice
95
96
High-efficiency Filter ULPA The world-famous AAF damp and fire resistant fiberglass high-efficiency air filter (HEAP) 99.99%@0.3µm, enjoys the cleaning class up to Class V, ISO14644.1 which is superior to the cleaning requirement of class 100, safer and cleaner
Featuring many patented technologies and authoritative testing certification for reliability Microcomputer intelligent control panel with durable touch buttons Multiple safety protection functions including UV delay start Interlocking function to put an end to incorrect operation Various personalized design to ensure comfortable operation Perfect memory function to avoid repeat setting Combined under-frame structure with universal truckle design
304 Stainless Operation Table The excellent 304 stainless operation table without fixing screws can avoid the accumulation of dirt
Ergonomic Design • Adopting recess lighting to eliminate the radiation of the fluorescent lamps on the eyes and thus preventing the eyes from being tired • Equalizer bar design: In the working area, the stainless equalizer bar with hooks is provided for facilitating the movement of articles
Patented Technology
High-efficiency Filter ULPA
• UV sterilization startup delay (keep away the injury by UV light) patent technology (ZL201220087011.4), After the UV lamp switch is pressed down, the audible and visual alarm will be activated to remind the operator to leave in time. After 10s, the UV light is on. Therefore, the operator can be protected from the injury by UV light • Preset function: It can preset the UV sterilization startup delay to provide users with more rest and to improve working efficiency, possessing the patent technology (ZL201220087011.4)
Interlocking Function Shell : Cold rolled electrostatic painting, anti -corrosion ability
With the interlocking between illuminating lamp and UV lamp, the UV lamp can become on only when the illuminating lamp is off; When the UV lamp is on, it can be off if pressing the daylight lamp. The risk of incorrect operation can be avoided
Memory Function The UV lamp startup delay time, sterilization duration, preset start time, fan position can be set and saved by user on request for the convenience of startup
UV Lamp One-key Preset
UV germicidal delayed start to prevent from away UV damage
One-key Operation • After the UV lamp switch is pressed, the time function can be activated automatically. The default sterilization time is 30min, which can be adjusted by user within 0~99min on request • Sterilization preset, when pressing the UV lamp, the preset lamp will become on to remind user that the sterilization preset function has been activated and that the sterilization preset can be conducted
Pre-cleaning Function
Pre-cleaning Function: patented technology (ZL201220087011.4)
304 Stainless Operation Table
UV lamps , fans, lighting linkage system to enhance user
97
Universal Caster to move more conveniently
Flow Type Voltage/Frequency Power Vibration Amplitude Exhaust Filter Typical Efficiency Average Velocity Fluorescent Lamp Intensity Net/Gross Weight Noise(dB(A)) Internal Dimension(W*D*H) External Dimension(W*D*H) Packing Dimension(W*D*H) Supporter Cleanliness Classification Container Load(20'/40'/40'H) Certificate
HCB-900V
HCB-1300V
Vertical 220V/50Hz 1200W ≤2um HEPA,99.99%@0.3um 0.2~0.5m/s ≥400 Lux 115/140(kg) 254/309(lbs) ≤60dB 900*550*520(mm) 35.4*21.7*20.5(in) 970*630*1730(mm) 38.2*24.8*68.1(in) 1105*745*1280(mm) 43.5*29.3*50.4(in) 750mm high chassis ISO14644.1 Class 5 7/30/15 CFDA
Vertical 220V/50Hz 1200W ≤2um HEPA,99.99%@0.3um 0.2~0.5m/s ≥600 Lux 145/175(kg) 320/386(lbs) ≤60dB 1300*550*520 (mm) 51.2*21.7*20.5(in) 1370*630*1730(mm) 53.9*24.8*68.1(in) 1505*745*1280(mm) 59.3*29.3*50.4(in) 750mm high chassis ISO14644.1 Class 5 3/30/15 CFDA
98
Clean Bench
The only pre-cleaning function can further improve the protection on sample
99
100
Liquid Nitrogen Container
Liquid Nitrogen Container Product Details
Haier Liquid Nitrogen Storage System Biobank Series
Top of the Container
Lid Open
Biobank Series has six models with capacity of 300, 500, 800, 1000, 1500, and 1800. Biobank Series is designed to ensure the maximum storage capacity with the minimum consumption of liquid nitrogen to lower the overall cost of operations.
Product Advantages Optimal Use of Storage Space Racks are stored on the rotating tray with an appropriate distance from the wall of the chamber. Liquid nitrogen or supercooled nitrogen vapor is filled in the space between the tray and the wall to maintain temperature uniformity. Storage space is equally divided into four or six fan-shaped storage rooms which are clearly labeled. Each storage room is easily rotated to the opening of the tank for convenient sample access. Advanced Vacuum Technology and Superinsulation Technology Haier Liquid Nitrogen Storage System Biobank Series applies advanced vacuum technology and superinsulation technology to ensure storage safety and temperature uniformity while reducing the consumption of liquid nitrogen. The temperature difference of the entire storage area does not exceed 10°C even in vapor phase storage, and temperature near the top of the shelf can be as low as -190°C.
Designed for Both Liquid and Vapor Phase Storage Each model of Biobank Series is designed for both liquid and vapor phase storage. For vapor phase storage, samples are kept away from the liquid nitrogen while stored in a uniform temperature that is close to the temperature range of liquid nitrogen.
Cryosmart Intelligent Liquid Nitrogen Control System Haier Liquid Nitrogen Storage System Biobank Series features Cryosmart system for complete monitoring and controlling. High-precision temperature and liquid level censors are used to ensure accuracy. All data and samples are protected by secure access control system.
A Low-temperature hose connects the inlet and liquid nitrogen tank for supplement. A silencer reduces the noise of nitrogen emission to grant a quiet environment.
Vapor condensation near the container opening is controlled. The strength of the container is reinforced at liquid nitrogen temperature to extend service life.
Features • Massive capacity between 13000 to 94875 ×2ml Vials.
• One-touch defogging for easier access.
• Vapor phase storage is the only guaranteed method to prevent cross-contamination
• LN splash proof make the operation more secure.
• Vapour phase storage at -190°C.
• Biobank storage compatible.
• 5 year vacuum warranty
101
102
Small self-pressurized liquid nitrogen supply system suitable for research institutes dealing with fewer samples.
Distribution of Racks and Holders
Distribution of Racks and Holders Technical Parameters Model
YDD-300-326
YDD-800-460
YDD-500-440
YDD-1000/ 1500/1800-635
YDD-300 -326
YDD-800 -460
YDD-1000 -635
YDD-1500 -635
YDD-1800 -635
Maximum Storage Capacity 2 ml Vials (Internal Thread)
13000
26000
42900
58500
76050
94875
12
24
32
54
54
60
4
8
4
18
18
13
10
10
13
10
13
15
18200
36400
58100
81900
99450
126500
Freeze Rack (100 wells) Freeze Rack (25 wells)
12
24
32
54
54
60
4
8
4
18
18
13
Layers of each rack
14
14
17
14
17
20
Freeze Rack (100 wells) Freeze Rack (25 wells) Layers of each rack
Holders
YDD-500 -440
0.5 ml Vials (Internal Thread)
Capacity Internal Capacity Volume of LN under the tray (L) Static Evaporation (%/Day)
25 ml Racks
350
590
890
1340
1660
1880
55
80
135
265
300
320
≤1.92
≤1.35
≤0.85
≤1.15
≤0.78
≤0.69
Dimensions Inside Neck Diameter (MM) Height (MM) Operating Height (MM) Outside Diameter (MM) Door Width Requirements (MM) Empty Weight (KG) Gross Weight (KG)
50 ml Racks
326
440
460
635
635
635
1326
1321
1559
1404
1589
1883
1263
1266
980
997
967
1097
870
1080
1180
1565
1565
1565
1000
1200
1300
1700
1700
1700
219
328
441
851
914
985
502
805
1160
1934
2255
2504
Total Total Total Total Total Total No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of No. Rack No. of Layers Racks Layers Racks Layers Racks Layers Racks Layers Racks of of of of of of Layers Racks Bags Bags Bags Bags Bags Bags
250 ml Racks
103
25 ml
1272
6
212 2376
6
396 3360
7
480 4716
6
786 5502
7
786 7758
9
862
50 ml
792
6
132 1416
6
236 2016
7
288 2916
6
486 3402
7
486 4905
9
545
250 ml
288
3
96
552
3
184
4
236 1950
4
390 1950
5
390 2095
5
419
944
104
Distribution of Racks and Holders
Blood bag capacity
Liquid Nitrogen Container
Biomedical
Liquid Nitrogen Container Technical Parameters Model
YDS-65-216-F
YDS-95-216-F YDS-115-216-F YDS-140-216-F YDS-175-216-F Maximum Storage Capacity
Haier Liquid Nitrogen Storage System Medical Series features low LN consumption and relatively small footprint for medium capacity sample storage.
Product Advantages ULT Storage with Extremely Low LN Evaporation Freezer racks are in the ultra-low temperature environment with extremely low LN evaporation. Even stored in vapor phase, the temperature will be below -190°C for a long time.
Advanced Vacuum Technol ogy and Superinsulation Technology Advanced vacuum and insulation technologies ensure cryopreservation for as long as four months.
Compatible for Blood Bag Storage According to users’ needs, Medical Series can be adapted to LN tanks for temporary storage of blood bags before transferred to larger scale LN storage.
No. of holders 2 ml Cryovials (100 per box) No. of boxes in (2ml each holder) 5 ml Cryovials (36 per box) No. of boxes in (5ml each holder)
6
6
6
6
6
2400
3000
3600
4800
6000
4
5
6
8
10
648
864
1080
1296
1728
3
4
5
6
8
Capacity
Volume of LN (L) Static Evaporation* (L/Day) Working Volume Duration of Normal** Operation (Day)
65
95
115
140
175
0.79
0.81
0.83
0.87
0.87
55
85
105
130
165
44
66
80
94
126
Dimensions
Auto-Refill System Auto-refill system is particularly suitable for vapor phase storage. For liquid phase storage, it can also facilitate users’ operations by avoiding frequent refills. The auto-refill system continuously monitors the inside temperature through ZTC-100B/100C Level Monitor, and automatically controls inlet valve to replenish LN. Although less economical, it provides accurate control and ensures safety storage for over 8 weeks.
216
216
216
216
216
Height(MM)
710
726
796
910
1026
Outside Diameter(MM)
681
681
681
681
681
Empty Weight(KG)
27.5
34.5
38.5
42.5
55
Gross Weight(KG)
80.8
112.4
132.8
157.3
198.5
* Static evaporation and static holding time is theoretical value. Actual evaporation and holding time is affected by usage, atmospheric conditions, and manufacturing tolerances. ** Duration of normal operation is for reference only to estimate container performance under normal operating conditions. Actual duration may differ due to different atmospheric conditions, usage history, manufacturing tolerances, and particular circumstances.
Features • 5 models from 2400 to 6000 cryovial capacity
• Durable aluminium construction
• High thermal efficiency
• Heavy duty lockable enclosure offers excellent security
• Temperature data-logging monitoring available
• 5 year vacuum warranty
• Compatible with all major cryobox brands
• Liquid or vapour phase option available
• Ultra-low evaporative Losses
Trolley
Holders
Cryogenic Boxes
216 Diameter Lock Cap
5 ml Customized Holder
5 ml Customized Cryogenic Box
106
Liquid Nitrogen Container
Accessories:
Level Monitor Liquid level monitor continuously and reliably monitors the temperature inside the tank and informs users to refill LN. It is suitable for institutes that require long time cryopreservation. Three models (ZTC-100A/100B/100C) are available. The monitor offers real-time temperature display and audible/visual alarms for high temperature, sensor failure, and low liquid level.
105
Opening Diameter(MM)
CO Incubator
Biomedical
CO Incubator
Haier CO incubators are widely applied to the research and production of medicine, immunology, genetics, microbiology, agricultural science and pharmacology. The incubators are ideal equipment for experimental study of in-vitro incubation of cells, tissue, microbes, etc.
Large Color Screen Display
Multiple Disinfection Methods
A: Microbe High-efficiency Filter
Easy to Clean
A high-efficiency microbe filter, which comes with a sterilization function, is installed at the CO gas inlet. Its filtration efficiency is 99.99 percent, capturing particulates with diameters equal and greater than 0.3 um. The filtration system eliminates bacteria and particulates in the CO gas to create a healthy environment for reliable experiments.
Standard features include stainless steel inner liner designed with rounded corners for ease of cleaning and anti-bacteria.
Space Saving Units are conveniently stackable to allow laboratory space fully utilized.
B: Door Frame Heating System
Protection Safety
Haier CO incubator’s outer door radiates heating energy into the inner glass door to prevent condensation from occurring. The dry inner door eliminates the possibility of microbial contamination that exists in condensate water.
Alarm systems feature an independent over-temperature alarm system, and a sound, illuminator system, and remote alert system that report temperature, humidity, door ajar, and malfunction conditions. The alarm systems safeguard experiments effectively.
C: Automatic Control of Circulating Fan Speed The air flow inside the chamber can be automatically controlled based on the requirement of an experiment. This feature reduces the risk of drying out test samples.
Specifications: Model
E: Ultraviolet Sterilization System
Input Power Screen Size
Ultraviolet sterilization system is positioned on the rear wall inside the incubator. It is used for quickly and effectively disinfecting the inside of the incubator body to kill any floating bacteria circulating in the air and water vapor in humidifying tray. This method thereby prevents potential contamination to cell incubation.
Heating Type
F: Fast Recovery of Test Environment The incubator system operates with a perfect interaction of the high-precision infrared CO temperature sensor and the microcomputer controller. The result is that the CO concentration and temperature can be recovered to the set state quickly even when the doors are opened and closed frequently. The system maintains an excellent stability and uniformity of CO concentration and temperature at high usage conditions. G: Microcomputer Controller A large-screen liquid crystal display is a standard feature for ease of operation and clear display. It is controlled by a microcomputer precisely, and it can display temperature, CO concentration, and relatively humidity. H: Built-in Water Tray Design The floor of the inner door is by design an integral built-in water tray for humidification process. Pure water can be introduced directly to the water tray for a greater area of evaporation. This feature eliminates a separate water tray design which can be a source of contamination. I: Graphic Inquiry In the incubation process, all key operational parameters such as temperature, humidity, CO concentration and door usage are shown in a graphic form. Users can quickly use the information directly to analyze the incubation process. J: Door Action Actuated Control When the door is opened, operation of circulating fan, CO injection and heating system automatically stops temporally to reduce CO gas consumption, and temperature overshoot. When the door is closed, the system resumes operation automatically. 107
Control Range Operating Ambient Temperature Temperature Stability CO Control Range CO Control Accuracy CO Recovery Time
Temperature Recovery
Relative Humidity
PYXE-80IR
PYXE-150IR
PYXE-240IR
500W
700W
1000W
5" LCD screen
5" LCD screen
5" LCD screen
Air jacked heating system with microcomputer control
Air jacked heating system with microcomputer control
Ambient Temperature +5~50°C
Ambient Temperature +5~50°C
Air jacked heating system with microcomputer control Ambient Temperature +5~50°C +5~30°C
+5~30°C
+5~30°C
±0.3°C
±0.3°C
±0.3°C
0~20%V/V
0~20%V/V
0~20%V/V
±0.1% (infrared sensor)
±0.1% (infrared sensor)
±0.1% (infrared sensor)
After the door is opened for 1 minute, CO concentration recovery time is less than 6 minutes.
After the door is opened for 1 minute, CO concentration recovery time is less than or 6 minutes.
After the door is opened for 1 minute, CO concentration recovery time is less than or 6 minutes.
After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed.
After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed.
After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed.
Volume Interior Dimension(WxDxH)
80L
150L
240L
400x450x500(mm)
480x530x610(mm)
600x630x670(mm)
Overall Dimension(WxDxH)
590x687x790(mm)
670x767x880(mm)
788x837x940 (mm)
2/6 pieces
3/10 pieces
3/10 pieces
/
3 glass door
/
Carrying Bracket Optional Sterilization Cycles
24hrs(90°C moist heat disinfection)24hrs(90°C moist heat disinfection) 24hrs(90°C moist heat disinfection) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization)
Disinfection Method
Disinfection methods include moist heat disinfection at temperature of 90°C and disinfection by ultraviole light. Users can choose one of the two methods based on specific applications.
108
CO2 Incubator
D: 90°C High-temperature Moist Heat Disinfection System Moist heat disinfection at high temperature of 90°C can kill microbes and fungal spores on the inner surface of the incubator.
Biomedical
Table Top Low Speed Large Capacity Centrifuge
Table Top Low Speed Large Capacity Centrifuge Rotor Rotor Description Capaciy Max Max Buckets AdaptersCapacity Speed RCF No. Trunnion 4×2×50ml 12×15ml 5500 5310 RPM ×g
No. 1
/
/
/
Adapter Adapter Capacity:8×15ml Capacity:8×50ml (Conical bottom) Adapter Adapter Capacity:8×50ml (Conical bottom) Capacity:8×3×5ml
Fixed Angle Rotor
Applicable to clinical medicine, cell culture lab, biological research, blood separation and purification. Several fixed angle rotors, horizontal rotors as well as variety of adapters available.
Rotor Rotor Description Capaciy Max Max Buckets AdaptersCapacity Speed RCF No.
2×2×96 4000 2200 wells RPM ×g
No. 3
/
/
Adapter Capacity:8×30ml Trunnion 4×2×100ml
/
No. 5
ELISA Plate Rotor
Adapter Adapter Capacity:4×15ml Capacity:4×50ml (Conical bottom) Adapter Adapter Capacity:4×50ml (Conical bottom)Capacity:4×3×5ml
LD-55T
Superior performance
Easy operation
• Microcomputer control system with large LCD screen • Brushless variable frequency motor provides large torque, prolonged service life and avoids carbon powder pollution • A variety of rotors, buckets and adaptors available
• Touch panel and digital display enable best user-friendly operations • User-adjustable centrifugal programs: parameters including speed, time, RCF and acceleration/deceleration curves are programmable 25 standard centrifugal programs to choose from
Optimal effect
Safety and reliability
• Nine accelerating and ten braking modes (Mode 0 for unbraked run-down) • Unique noise reduction technology • Three levels of dampers to reduce vibration while optimal centrifugal effect.
• Automatic cover lock • Over-speed and misoperation protection • Motor and frequency changer fault detection • Stainless steel chamber with three protective sleeves to ensure the safety
No. 4 Swing-ut Rotor Capaciy: 4×100ml Max Speed : 5000 RPM Max RCF : 4390×g
Max Speed
Adapter Capacity:4×20ml
5310 xg
Max Capacity
4x500ml
Timing Range
1min~99min (LED) 30s~99min59s(LCD)
Minimum Acceleration/Deceleration Time
55s/55s
Speed Accuracy
± 30RPM
Power Supply
AC 220 ± 22V 50Hz/60Hz 10A
Gross Power
1000W
Noise
Adapter Capacity:4×4 hematocrit tube
Adapter Adapter Capacity:4×15ml Capacity:4×3×1.5ml
Capacity:500ml Tube/Bottle Bucket
No. 2
Adapter Capacity:8×15ml
Capacity:8×3×1.5ml
Adapter
Capacity:10ml
Adapter
Capacity:7ml
Adapter
Capacity:5ml
Bucket Capacity:4×16×5ml/7ml
Bucket Capacity:4×12×5ml/7ml
Adapter
Capacity:4×300ml
Capacity:4×3×50ml
Adapter
Adapter
Capacity:4×100ml
Capacity:4×7×20ml
Adapter
Adapter
Capacity:4×19×5ml
Adapter Capacity:4×10×15ml
Swing-out Rotorc Capaciy: 4×500ml Max Speed : 4000 RPM Max RCF : 3040×g
Adapter Capacity:8×4 hematocrit tube Adapter
Adapter
Adapter Capacity:4×10×15ml (Conical bottom)
5500RPM
Max Relative Centrifugal Force(RCF)
Max Speed : 4200 RPM Trunnion Max RCF : 3100×g 4×8×15ml
Adapter Adapter Capacity:4×30ml Capacity:4×2×10ml
LD-55T
Model
Capaciy: 8×100ml
Adapter Capacity:8×20ml
Adapter Capacity:8×2×10ml
Capacity:4×9×15ml (Conical bottom) Adapter Capacity:4×28×5ml Adapter Capacity:4×4×50ml (Conical bottom)
Adapter
Adapter
Capacity:4×20×10ml
Capacity:4×4×50ml
Adapter
Adapter
Capacity:4×25×1.5ml
Capacity:4×250ml
Rectangular Bucket
<65dB (A) 470x550x390 (mm)
Chamber Diameter
Ф400 mm
Net Weight
50kg
109
4×24×7ml Vacuum blood tube bucket
ELISA Plate Bucket 4×2×96-well microplate
110
Lab Centrifuge
Overall Size (LxWxH)
Table Top High Speed Refrigerated Centrifuge
Table Top High Speed Refrigerated Centrifuge LG-LG-165TD (Refrigerated)
LG-165T
Adapter Rotor Rotor Max Max No. Description Capaciy Speed RCF Adapters Specifi cation
Applicable to radiation immunity, biochemistry, bio-pharmaceuticals, blood separation and purification.
12×1.5ml
No. 1
LG-165TD
Superior performance
Easy operation • Touch panel and digital display enable best user-friendly operations • User-adjustable centrifugal programs: parameters including speed, time, RCF and acceleration/deceleration curves are programmable 25 standard centrifugal programs to choose from
• Automatic rotor identification system • Automatic cover lock • Over-speed and misoperation protection • Motor and frequency changer fault detection • Stainless steel chamber with three protective sleeves to ensure the safety
36×1.5ml/2.2ml
12×10ml
Timing Range
30s~99min59s
1min~99min
-20°C ~ 40 °C
-
±2.0°C
-
50s/50s
35s/25s
Speed Accuracy
0.5ml
Adapter
0.5ml
Adapter
1.5ml
No. 2 Adapter
1.5ml
Adapter
0.2ml
12×5ml Fixed-Angle Rotor
No. 3 Adapter
13500 12835 RPM ×g
12×10ml
Adapter
Fixed-Angle Rotor
0.5ml
5ml
12300 15550 RPM ×g
1.5ml
Adapter
No. 4
Fixed-Angle Rotor
36×1.5ml /2.2ml
0.2ml
No. 4
11000 10790 RPM ×g
4×10ml
6000 RPM
3200 ×g
Swing-out Rotor
4×10ml Trunnion Trunnion
Adapter
2×5ml
0.5ml
No. 5 Swing-out ELISA Rotor
2×2×48 wells
3000 RPM
1400 ×g
2×48 wells Trunnion
No. 5
48×0.5ml
12000 10920 RPM ×g
Adapter
/
Fixed-Angle Rotor
24×1.5ml /2.2ml
No. 6
Adapter
0.2ml
Adapter
0.5ml
Adapter
/
15000 21532 RPM ×g
Fixed-Angle Rotor
± 50 RPM
Power Supply
AC 220 ± 22V 50Hz 10A
AC 220 ± 22V 50Hz/60Hz 10A
Gross Power
1000W
400W
Noise
Net Weight
Adapter
21532×g
Max Capacity
Chamber Diameter
0.5ml
16500 RPM
Max Relative Centrifugal Force(RCF)
Overall Size (L×W×H)
Adapter
LG-165T
LG-165TD (Refrigerated)
Max Speed
Minimum Acceleration/Deceleration Time
0.5ml
Safety and reliability
• Nine accelerating and ten braking modes (Mode 0 for unbraked run-down) • Unique noise reduction technology • Three levels of dampers to reduce vibration while optimal centrifugal effect.
Temperature Control Accuracy
Adapter
15000 21532 RPM ×g
Fixed-Angle Rotor
Adapter
Adapter
Optimal effect
Temperature Control Range
24×1.5ml /2.2ml
No. 3
0.2ml
16500 18930 RPM ×g
Fixed-Angle Rotor
12000 10142 RPM ×g
Fixed-Angle Rotor
• Microcomputer control system with large LCD screen • Brushless variable frequency motor provides large torque, prolonged service life and avoids carbon powder pollution • A variety of rotors, buckets and adaptors available • Equipped with high-efficiency CFC-free refrigeration system (Non-refrigerated model available as LG-165T)
Model
12×5ml
12×1.5ml /2.2ml
No. 1
Adapter
Fixed-Angle Rotor
No. 2
0.2ml
16500 18360 RPM ×g
Rotor Rotor Max Max Adapters Adapter No. Description Capaciy Speed RCF /Buckets Specifi cation
No. 6
<65dB (A) 345×590×340 (mm)
385×640×330 (mm)
Ф250mm
Ф280mm
70 kg
18 kg
111
Fixed-Angle Rotor
3×8×0.2ml PCR Strip
15000 13800 RPM ×g
Adapter
/
No. 7
48×0.5ml Fixed-Angle Rotor
112
13500 13810 RPM ×g
Lab Centrifuge
Biomedical
Water Purification System
Biomedical
Water Purification System Superior Performance
Haier CSJM Water Purification System applies advanced technologies to provide purified laboratory water with highest quality. Depends on the requirements of your specific procedure and application, Haier CSJM Water Purification System Series Q/S/D/R can produce reverse osmosis (RO) purified water, deionized (DI) water, and ultrapure (UP) water with resistivity of 18.2 mΩ•cm at 25 °C. Haier Water Purification System is essential for your laboratory.
• • • • • •
High-end RO membranes and long-lasting KDF filters to ensure water quality while reducing costs Four independent ultra-purification cartridges, using nuclear grade resin to assure best quality NSF certified pure water pipes and joints Large flux (0.45 + 0.1) µm polyether compound filter terminal disinfection filter to secure sterilized Water Built-in 185 and 254 nm ultraviolet lamp to product low TOC water required by organic-sensitive applications (Optional) MWCO 5000D PES UF module to eliminate endotoxin for optimized cell cultivation and IVF (Optional)
Reliability and Safety • Three-way water quality sensors provide real-time monitoring for feed water, reverse-osmosis purified water and ultrapure water • Recirculation system to keep the quality of ultrapure water when system not in use • Visual and auditory alarms on water empty and full • User-defined water quality alarm for feed water, RO purified water and ultrapure water • Automatic malfunction detection to ensure safety • Settings are password protected to avoid unauthorized operation • RS232/USB ports (Optional) for GLP compliant water quality recording
Easy operation and maintenance • • • • • • • • Feed water
Output water
Applications
·General biochemistry experiment ·Pretreated water for ultrapure water Type II analytical grade machines,and applications (Parameters close to Type 1) with water quality requirements such as cleaning and humidifying.
Basic purification
LG-165T processes
CSJM-Q
Tap water
CSJM-S CSJM-D
Tap water
Type I ultrapure
Precision experiment
PF+KDF+AC+RO+AC+DI+TF
Distilled or purified water
Type I ultrapure
Precision experiment
AC+DI+TF
CSJM-R
Tap water
pure /ultrapure water
113
General or precision experiment,feed ultrapure water system
PF+KDF+AC+RO+AC+DI
PF+KDF+AC+RO+RO+AC
114
Water Purification System
Series
240*128 graphical LCD display, multi-menu operating Unique on duty/off duty modes to keep the abundance of RO purified water Different sizes of tanks to meet every need and assure ample water-supply Modular structure for the convenience of cartridge maintaining and replacing One-touch operation for whole pipeline sterilization program Consumable life-span display and auto-reminding to avoid the decline of water quality Automatic RO membrane flushing procedure User-programmable water dispenser based on time and quality
CSJM-Q Series Deionized Water System
CSJM-S Series Ultrapure Water System
Fed tap water, Haier CSJM-Q Series pure water system produces analytical-grade reverse osmosis purified and deionized water with resistivity of 16-18.2 mΩ•cm (25°C) at 15 to 30 L/min. Suitable for general chemical and biological laboratory applications.
Fed tap water, conveniently produces 18.2 m Ω•cm ultrapure water at 15-30 L/min. Water quality meets or exceeds the standards of ASTM/CAP/CLSI/EP /USP Type I water. Ideal for more critical biological and analytical applications.
Applications • Glassware washing
• Feed ultrapure water system
• Buffer and media preparation
• Sample dilution and reagent preparation
• Microbiological analysis • Spectrometry measurements • Water analysis and general HPLC • General Chemistry and Qualitative Analysis • Feed laboratory devices, such as autoclaves, washing machines, automatic biochemical analyzer, immunoassay analyzer, humidity chamber, salt spray chamber, aging instrument, humidifiers, and so on
Specification Model Feed Water Requirements* Process Flow**
CSJM-Q15
CSJM-Q15UT
CSJM-Q30
CSJM-Q30UT
Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2. (Additional Water softener recommend when TDS>200 ppm ) PF+KDF+AC+RO+AC+DI
PF+KDF+AC+RO+AC+DI+UV+TF
N/A
<0.1 ppb
N/A
<0.1 cfu/ml
Bacteria
N/A
<0.1 cfu/ml
N/A
<1/ml
<1/ml
Particulates (>0.2µm) Ion rejection Rate Rejection of Organic Contaminants
• Molecular Biology, Microbiology
• Preparation of cells and culture media
• ICP-MS/AAS/GF-AAS • Electrochemical
• Mammalian Cell Culture • DNA sequence analysis
• PCR applications and analyses • Electrophoresis, gel analysis
• Ultra-trace, trace mineral, trace organics analysis • Monoclonal Antibody Production
Hybird
Model
CSJM-S15
CSJM-S15UF
CSJM-S15UV
CSJM-S15UVF
High Capacity
CSJM-S30
CSJM-S30UF
CSJM-S30UV
CSJM-S30UVF
Feed Water Requirements*
PF+KDF+AC+RO+
PF+KDF+AC+RO+
PF+KDF+AC+RO+
PF+KDF+AC+RO+
AC+DI+TF
AC+DI+UF+TF
UV+AC+DI+TF
UV+AC+DI+UF+TF
Resistivity
18.2 mΩ•cm (25°C)
Heavy Metal Ions
<0.1 ppb
Total Organic Carbon
<10 ppb
<3 ppb <0.1 cfu/ml
N/A
<0.01 ng/ml
N/A
<0.01 ng/ml
Particulates (>0.2µm)
N/A
<1/ml
N/A
<1/ml
RNases
N/A
<0.01 ng/ml
N/A
<0.01 ng/ml
DNases
N/A
<4 pg/µl
N/A
<4 pg/µl
30 L/h
WxDxH: 500x360x540 mm, 22 kg 220V/50Hz, 120W Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories
Ion Rejection Rate
* Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, TF: Terminal Microfiltration *** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery
96%-99% (with new RO membranes)
Rejection of Organic Contaminants
>99% , when MW>200 Dalton
Rejection of Particulates and Bacteria
>99%
Water Production Rate (25°C) *** Instant Dispensing Rate Water Outlets
S15: 15 L/h, S30: 30 L/h 2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate) Two: Reverse Osmosis purified water, and Ultrapure water
Dimensions
WxDxH: 500x360x540 mm, 25 kg
Power Supply/Power Standard System Configuration
115
Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm )
Pyrogen(Endotoxin)
Two: Reverse Osmosis Purified water and Deionized water
Power Supply/Power
Low Levels of Organics
>99% , when MW>200 Dalton
2.0 L/min (Pressure tank required)
Dimensions
Pyrogen-Removal
96%-99% (with new RO membranes)
15 L/h
Instant Dispensing Rate
Standard Normal
Model Features
Bacteria
>99%
Rejection of Particulates and Bacteria
Standard System Configuration
• TOC analyses, IC
Process Flow**
16-18.2 mΩ•cm (25°C)
Heavy Metal Ions
Water Outlets
• HPLC/GC-MS/ICP-AES
Specification
Resistivity
Water Production Rate (25°C) ***
Applications
220V/50Hz, 120W Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories
* Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery
116
Water Purification System
Biomedical
CSJM-D Series Ultrapure Water System
Biomedical
CSJM-R Series Two Stage Reverse Osmosis Pure/ Ultrapure Water System
Fed tap water, produce ultrapure water with conductivity of 1-5 µs/cm at 15-20 L/h, even if the source water is of relative poorer quality. Two-stage reverse osmosis system has with dual pumps, dual RO membranes, and a middle tank. Compared with single-stage system, two-stage RO purification system will not only produce purified water with more stable quality, but also reduce the cost of subsequent purification modules.
Fed purified water, dispense up to 2 liters of 18.2 mΩ·cm Type I water per minute. Pretreated source water enables more stable ultrapure water quality, which meets or exceeds the standards of ASTM/CAP/CLSI/EP/USP Type I water. Suitable for critical laboratory applications.
Applications • HPLC/GC-MS/ICP-AES • ICP-MS/AAS/GF-AAS • TOC analyses, IC
Applications • Electrochemical
• Molecular Biology, Microbiology
• Mammalian Cell Culture • DNA sequence analysis
• PCR applications and analyses • Electrophoresis, gel analysis
• Preparation of cells and culture media
• Glassware washing
• Spectrometry measurements
• DNA sequence analysis
• Sample dilution and reagent preparation
• Monoclonal Antibody Production
• Microbiological analysis
• Buffer and media preparation
• Electrophoresis, gel analysis
• General Chemistry and Qualitative Analysis
• Ultra-trace, trace mineral, trace organics analysis
• TOC analyses, IC
• HPLC/GC-MS/ICP-AES
• Mammalian Cell Culture
• Water analysis and general HPLC
• Electrochemical
• Molecular Biology, Microbiology
• Monoclonal Antibody Production
• Preparation of cells and culture media
• ICP-MS/AAS/GF-AAS
• PCR applications and analyses
• Ultra-trace, trace mineral, trace organics analysis
• Feed laboratory devices, such as autoclaves, washing machines, automatic biochemical analyzer, immunoassay analyzer, humidity chamber, salt spray chamber, aging instrument, humidifiers, and so on
Specification Model Feed Water Requirements* Process Flow**
Standard
Pyrogen-Removal
Low Levels of Organics
Hybird
CSJM-D
CSJM-DUF
CSJM-DUV
CSJM-DUVF
AC+DI+TF
AC+DI+UF+TF
UV+AC+DI+TF
Two-stage RO Ultrapurification
Model
CSJM-RRO
CSJM-RQ
CSJM-R /UF /UV /UVF
Feed Water Requirements * Process Flow**
<0.1 ppb
Total Organic Carbon***
<10 ppb
<3 ppb
RO Water
<0.1 cfu/ml
Bacteria N/A
<0.001 Eu/ml
N/A
<0.001 Eu/ml
<1/ml
Particulates (>0.2µm) RNases
N/A
<0.01 ng/ml
N/A
<0.01 ng/ml
DNases
N/A
<4 pg/µl
N/A
<4 pg/µl
Resistivity
≥5 mΩ•cm
Water Production Rate (25°C) ****
Up to 2.0 L/min Two: Deionized water, and Ultrapure water
Dimensions
WxDxH: 500x360x540 mm, 20 kg
Power Supply/Power Standard System Configuration
Two-stage RO and DI Purification
UV+AC+DI+UF+TF
18.2 mΩ•cm (25°C)
Heavy Metal Ions
Water Outlets
Two-stage RO Purificatoin
Reverse Osmosis purified water, distilled water or deionized water, 5-45 °C, 1 atm
Resistivity
Pyrogen(Endotoxin)
Model Features
220V/50Hz, 120W Water Purification Unit, accessories
* Feed water affects the quality of purified water, as well as life-span of purification modules ** AC: Activated Carbon, DI: Deionization, UV: Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Depends on source water quality ****Installation of terminal microfiltration or ultrafiltration membrane will reduce the flow rate
117
Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm ) PF+KDF+AC+RO+RO+AC
PF+KDF+AC+RO+RO+AC+DI+TF
PF+KDF+AC+RO+RO (+UV)+AC+DI(+UF)+TF
First stage RO water (TDS): Conductivity ≈ 5% source water conductivity; Second stage RO water (TDS): 1-5 µs/cm (conductivity≤% source water conductivity); Organic contaminants rejection>99% (when MW>200 Dalton); Particulates and bacteria rejection>99%
DI Highly Purified Water
RQ Series: Resistivity: 16-18.2 mΩ•cm, heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2µm)<1/ml
Ultrapurified Water
R Series: Resistivity: 18.2 mΩ•cm (25°C), heavy metal ions<0.1 ppb, bacteria <0.1 cfu/ml, particulates(>0.2µm)<1/ml, TOC<10 ppb ***, (UV/UVF Series: TOC<3 ppb***) UF/UVF Series: Pyrogen<0.001 Eu/ml, RNases<0.01 ng/ml, DNases<4pg/µl 15-20 L/h
Water Production Rate (25°C) ****
2.0 L/min
Second Stage Instant Dispensing Rate Water Outlets Dimensions
Two: Stage I, II RO water
Two: Stage II RO water, DI water 220V/50Hz, 120W
Power Supply/Power Standard System Configuration
Two: Stage II RO water, ultrapure water
WxDxH: 500x360x540 mm, about 30 kg
Water Purification Unit (with one set of purification modules), Tank Set (internal water level tank ×1 + 15 L external pressure tank × 1), accessories
* Feed water affects the quality of purified water, as well as life-span of purification modules ** PF: Pre-Filtration, KDF: copper and zinc based KDF water filtration, AC: Activated Carbon, RO: Reverse Osmosis, DI: Deionization, UV: 254 nm Ultraviolet disinfection, UF: Ultrafiltration, TF: Terminal Microfiltration *** Depends on source water quality **** Feed water TDS=200 ppm, measured at 25°C, 50 psi and 15% recovery
118
Water Purification System
Model Features
Specification
m
Biomedical
Models Line-up
m
Models Line-up
F
HTC-40
HTC-110
HTD-40
HTCD-90
Clean Bench
light
F
119
120
Haier Biomedical Models Line-up
Liquid Nitrogen CO Lab Water PurificContainer Incubator Centrifuge ation System